[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-37":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":627},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,37,50,2054,[13,35,47,59,72,86,98,110,122,134,147,159,171,183,196,208,220,232,244,256,268,280,292,304,316,328,340,352,363,375,387,398,410,423,435,447,459,471,484,496,508,520,532,544,556,568,579,591,603,615],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},881651,2,"多选题","采暖管道安装中，管道弯曲半径的确定，下列哪几项是错误的？",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","钢制焊接弯头，应不小于管道外径的3倍",true,{"key":24,"text":25,"correct":26},"B","钢制管道热弯，应不小于管道外径的3.5倍",false,{"key":28,"text":29,"correct":26},"C","钢制焊接冷弯，应不小于管道外径的4倍",{"key":31,"text":32,"correct":22},"D","塑料管道弯头，应不小于管道外径的4.5倍","AD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":33,"analysis":34},881652,"关于密闭罩的论述，下列哪几项是正确的？( )",[39,41,43,45],{"key":20,"text":40,"correct":22},"局部密闭罩适用于含尘气流速度低，瞬时增压不大的扬尘点",{"key":24,"text":42,"correct":26},"密闭罩的排风量为物料下落时带人罩内的诱导空气量",{"key":28,"text":44,"correct":26},"密闭罩的排风口应设在压力较低的部位",{"key":31,"text":46,"correct":22},"密闭罩的吸风口风速不宜过高",{"id":48,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":49,"answer":58,"analysis":34},881653,[50,52,54,56],{"key":20,"text":51,"correct":26},"工作压力低",{"key":24,"text":53,"correct":26},"制冷效率高",{"key":28,"text":55,"correct":22},"汽化潜热大、传热性能好",{"key":31,"text":57,"correct":22},"纯天然物质，不破坏环境","CD",{"id":60,"libraryId":5,"type":15,"typeLabel":16,"stem":61,"options":62,"answer":71,"analysis":34},881654,"某厂区锅炉房供应工艺和冬季供暖用热，在进行锅炉房设计时，下列哪些做法是正确的？( )",[63,65,67,69],{"key":20,"text":64,"correct":26},"为避免锅炉烟气污染，锅炉房应位于冬季主导风向下游",{"key":24,"text":66,"correct":22},"为节省投资并有利于运行管理，锅炉台数不宜超过5台",{"key":28,"text":68,"correct":22},"为提高运行效率，单台锅炉实际运行负荷率不应低于50%",{"key":31,"text":70,"correct":26},"为有利于运行调节，宜采用大、中、小容量锅炉搭配","BC",{"id":73,"libraryId":5,"type":74,"typeLabel":75,"stem":76,"options":77,"answer":31,"analysis":34},881655,1,"单选题","在电子工业洁净厂房设计中，同一防火分区的丙类洁净室(区)，人员密度小于0.02人\u002F㎡，而且疏散距离小于80m时，洁净室(区)( )。",[78,80,82,84],{"key":20,"text":79,"correct":26},"必须设机械排烟设施",{"key":24,"text":81,"correct":26},"宜设机械排烟设施",{"key":28,"text":83,"correct":26},"不设机械排烟设施",{"key":31,"text":85,"correct":22},"可不设机械排烟设施",{"id":87,"libraryId":5,"type":74,"typeLabel":75,"stem":88,"options":89,"answer":20,"analysis":34},881656,"绿色民用建筑评价阶段分为几个阶段？( )",[90,92,94,96],{"key":20,"text":91,"correct":22},"2个",{"key":24,"text":93,"correct":26},"3个",{"key":28,"text":95,"correct":26},"4个",{"key":31,"text":97,"correct":26},"5个",{"id":99,"libraryId":5,"type":74,"typeLabel":75,"stem":100,"options":101,"answer":24,"analysis":34},881657,"下列哪一项有关除尘器效率、阻力的变化关系的论述是错误的？( )",[102,104,106,108],{"key":20,"text":103,"correct":26},"除尘器的全效率越大，其穿透率就越小",{"key":24,"text":105,"correct":22},"旋风除尘器能处理粉尘的分割粒径大，其除尘总效率高",{"key":28,"text":107,"correct":26},"袋式除尘器的阻力随处理风量的增加而增加",{"key":31,"text":109,"correct":26},"粉尘的比电阻过大或过小，都会降低电除尘器的效率",{"id":111,"libraryId":5,"type":74,"typeLabel":75,"stem":112,"options":113,"answer":28,"analysis":34},881658,"关于空调水系统的循环水泵设置原则中，正确的是( )。",[114,116,118,120],{"key":20,"text":115,"correct":26},"二级泵系统一定比一级泵系统节能",{"key":24,"text":117,"correct":26},"管道局部阻力和水泵扬程均取10%的安全系数",{"key":28,"text":119,"correct":22},"定流量运行的一级泵的冷水循环泵台数和流量应与冷水机组的台数和流量相对应",{"key":31,"text":121,"correct":26},"冷水泵与热水泵宜兼用",{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":33,"analysis":34},881659,"有关排烟系统阀门的启闭状态表述，下列哪几项是错误的?( )。",[126,128,130,132],{"key":20,"text":127,"correct":22},"排烟阀平时是呈开启状态",{"key":24,"text":129,"correct":26},"排烟防火阀平时是呈开启状态",{"key":28,"text":131,"correct":26},"排烟阀平时是呈关闭状态",{"key":31,"text":133,"correct":22},"排烟防火阀平时是呈关闭状态",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":146,"analysis":34},881660,"大型螺杆压缩式制冷机组采用的制冷剂，正确的说法应是下列哪几项？( )",[138,140,142,144],{"key":20,"text":139,"correct":22},"A.制冷剂R134a，R407R410A不破坏臭氧层，但会产生温室效应",{"key":24,"text":141,"correct":22},"采用新技术，减少制冷剂氨的充注量并加强安全防护，可使氨制冷机组得到推广",{"key":28,"text":143,"correct":26},"在名义工况下，当压缩机排量相同时，R22为制冷剂的制冷机组的效率高于氨为制冷剂的制冷机组",{"key":31,"text":145,"correct":22},"在名义工况下，当压缩机排量相同时，氨为制冷剂的制冷机组的效率高于R134a为制冷剂的制冷机组","ABD",{"id":148,"libraryId":5,"type":74,"typeLabel":75,"stem":149,"options":150,"answer":20,"analysis":34},881661,"人防地下室平时、战时分设通风系统时，滤毒通风管路上的设备按( )选用。",[151,153,155,157],{"key":20,"text":152,"correct":22},"战时滤毒式风量",{"key":24,"text":154,"correct":26},"战时清洁式风量",{"key":28,"text":156,"correct":26},"平时新风量",{"key":31,"text":158,"correct":26},"平时、战时的最大新风量",{"id":160,"libraryId":5,"type":74,"typeLabel":75,"stem":161,"options":162,"answer":24,"analysis":34},881662,"有关通风机的论述，下列哪一种说法是错误的？( )",[163,165,167,169],{"key":20,"text":164,"correct":26},"通风机的全压等于出口气流全压与进口气流全压之差",{"key":24,"text":166,"correct":22},"通风机的全压等于出口气流全压",{"key":28,"text":168,"correct":26},"通风机的轴功率大于有效功率",{"key":31,"text":170,"correct":26},"通风机的风压系指全压，为动压和静压之和",{"id":172,"libraryId":5,"type":74,"typeLabel":75,"stem":173,"options":174,"answer":20,"analysis":34},881663,"高层民用建筑中的塔式住宅，在哪种情况下应设防烟楼梯？( )",[175,177,179,181],{"key":20,"text":176,"correct":22},"10层及10层以上",{"key":24,"text":178,"correct":26},"11层以上",{"key":28,"text":180,"correct":26},"12层以上",{"key":31,"text":182,"correct":26},"19层及19层以上",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":195,"analysis":34},881664,"目前常用的建筑空调能耗计算方法包括( )。",[187,189,191,193],{"key":20,"text":188,"correct":22},"逐时模拟计算法",{"key":24,"text":190,"correct":22},"负荷频率表法",{"key":28,"text":192,"correct":22},"当量满负荷时间法",{"key":31,"text":194,"correct":26},"谐波反应法","ABC",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":33,"analysis":34},881665,"多联机空调系统制冷剂管道的气密性试验做法，下列哪几项不符合规定?( )。",[200,202,204,206],{"key":20,"text":201,"correct":22},"R410A高压系统试验压力为3.0MPa",{"key":24,"text":203,"correct":26},"应采用干燥压缩空气或氮气",{"key":28,"text":205,"correct":26},"试验时要保证系统的手动阀和电磁阀全部开启",{"key":31,"text":207,"correct":22},"系统保压经24h后，当压力降大于试验压力2%时，应重新试验",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":195,"analysis":34},881666,"关于房间气流组织的说法，下列哪几项是正确的？( )",[212,214,216,218],{"key":20,"text":213,"correct":22},"在射流主体段内，射流断面的最大流速随距离增加而减小",{"key":24,"text":215,"correct":22},"回风口处的速度随距离增加迅速衰减，因此回风口对室内气流组织的影响比送风口小",{"key":28,"text":217,"correct":22},"座椅下送风的出口风速为0.2m\u002Fs以下时，可以避免吹风感",{"key":31,"text":219,"correct":26},"用CFD方法可以模拟设计工况下的流场、温度场、湿度场和污染物浓度场，但是仍需要以经验参数为主",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":58,"analysis":34},881667,"关于溴化锂吸收式制冷机，下列说法中错误的是( )。",[224,226,228,230],{"key":20,"text":225,"correct":26},"机组冷量可实现10%～100%范围内的无级调节",{"key":24,"text":227,"correct":26},"溶液泵和制冷剂泵必须采用屏蔽泵",{"key":28,"text":229,"correct":22},"双效型溴化锂吸收式制冷机发生器内溶液温度较高，所以相比单效型溶液更易发生结晶",{"key":31,"text":231,"correct":22},"为避免换热器内静液柱压力造成溶液温度升高，吸收器和发生器均应采用喷淋式换热器",{"id":233,"libraryId":5,"type":74,"typeLabel":75,"stem":234,"options":235,"answer":28,"analysis":34},881668,"建筑高度为49m的高级宾馆，每层合用前室可开启外窗面积2.5㎡，防烟楼梯间无外窗。应采取的防排烟措施为( )。",[236,238,240,242],{"key":20,"text":237,"correct":26},"可以通过合用前室自然排烟，烟就不会进入楼梯间",{"key":24,"text":239,"correct":26},"防烟楼梯间加压送风，合用前室自然排烟",{"key":28,"text":241,"correct":22},"防烟楼梯间和合用前室分别加压送风",{"key":31,"text":243,"correct":26},"按照“前室不送风”的计算条件，确定防烟楼梯间加压送风量",{"id":245,"libraryId":5,"type":74,"typeLabel":75,"stem":246,"options":247,"answer":31,"analysis":34},881669,"某地表水水源热泵机组，河水侧采用闭式盘管换热器，运行一年后，发现机组效果严重下降，经检查发现机组盘管换热器的管束内侧堵塞，观察到焊接的闭式盘管出现众多腐蚀，烂穿的细小孔洞，造成了河水进入盘管。试判断引起该故障的原因是下列哪一项？",[248,250,252,254],{"key":20,"text":249,"correct":26},"施工时盘管管材的焊缝未实现满焊",{"key":24,"text":251,"correct":26},"施工时盘管收到外部物体的碰撞引起破裂",{"key":28,"text":253,"correct":26},"盘管的弯管部分因疲劳出现断裂",{"key":31,"text":255,"correct":22},"盘管管材采用镀锌钢管",{"id":257,"libraryId":5,"type":74,"typeLabel":75,"stem":258,"options":259,"answer":28,"analysis":34},881670,"多层建筑可采用顶棚下凸出不小于( )的结构梁划分防烟分区o",[260,262,264,266],{"key":20,"text":261,"correct":26},"300mm",{"key":24,"text":263,"correct":26},"400mm",{"key":28,"text":265,"correct":22},"500mm",{"key":31,"text":267,"correct":26},"600mm",{"id":269,"libraryId":5,"type":74,"typeLabel":75,"stem":270,"options":271,"answer":31,"analysis":34},881671,"生产厂房的空调系统在无生产负荷的联合试运转及调试中，不符合规定的调试要求应是下列哪一项？( )",[272,274,276,278],{"key":20,"text":273,"correct":26},"系统总风量测试结果与设计风量偏差不应大于10%",{"key":24,"text":275,"correct":26},"系统冷热水、冷却水总流量测试结果与设计流量的偏差不应大于10%",{"key":28,"text":277,"correct":26},"空调室内噪声应符合设计规定要求",{"key":31,"text":279,"correct":22},"系统平衡调整后，各空调机组的水流量应符合设计要求，允许偏差为15%",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":146,"analysis":34},881672,"洁净室顶棚和壁板(包括夹心材料)应为不燃烧体，符合要求的材料是( )。",[284,286,288,290],{"key":20,"text":285,"correct":22},"机制岩棉夹心彩钢板",{"key":24,"text":287,"correct":22},"手工岩棉夹心彩钢板",{"key":28,"text":289,"correct":26},"聚苯板夹心彩钢板",{"key":31,"text":291,"correct":22},"石膏板夹心彩钢板",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":146,"analysis":34},881673,"根据检修要求，必须在竖向管道井的井壁上设置检修门。按现行消防设计规范对检修门设置的要求，下列哪些设置是错误的？( )",[296,298,300,302],{"key":20,"text":297,"correct":22},"甲级防火门",{"key":24,"text":299,"correct":22},"乙级防火门",{"key":28,"text":301,"correct":26},"丙级防火门",{"key":31,"text":303,"correct":22},"普通门",{"id":305,"libraryId":5,"type":74,"typeLabel":75,"stem":306,"options":307,"answer":31,"analysis":34},881674,"关于通风机风压的含义，( )是正确的。",[308,310,312,314],{"key":20,"text":309,"correct":26},"通风机的风压指风机进出口动压差",{"key":24,"text":311,"correct":26},"通风机的风压指风机动压",{"key":28,"text":313,"correct":26},"通风机的风压指风机静压",{"key":31,"text":315,"correct":22},"通风机的风压指风机动压和静压之和",{"id":317,"libraryId":5,"type":74,"typeLabel":75,"stem":318,"options":319,"answer":24,"analysis":34},881675,"关于制冷设备及系统的自控，下列哪项说法是错误的?( )。",[320,322,324,326],{"key":20,"text":321,"correct":26},"制冷机组的能量调节由自身的控制系统完成",{"key":24,"text":323,"correct":22},"制冷机组运行时，需对一些主要参数进行定时监测",{"key":28,"text":325,"correct":26},"水泵变频控制可利用最不利环路末端的支路两端压差作为信号",{"key":31,"text":327,"correct":26},"多台机组运行的系统，其能量调节除每台机组自身调节外，还需要对台数进行控制",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":146,"analysis":34},881676,"关于制冷机房的通风设计，正确的是( )。",[332,334,336,338],{"key":20,"text":333,"correct":22},"无自然通风条件时，应设置机械通风",{"key":24,"text":335,"correct":22},"事故排风口的高度宜按制冷剂的种类分别考虑",{"key":28,"text":337,"correct":26},"氟制冷机房的事故排风口上沿距室内地坪距离不应大于1.5m",{"key":31,"text":339,"correct":22},"夏季机房内温度不宜高于35℃",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":351,"analysis":34},881677,"关于民用建筑供暖管道中热媒的流速，设计错误的是( )。",[344,346,348,350],{"key":20,"text":345,"correct":22},"室内热水供暖管道内水流速为2.5m\u002Fs",{"key":24,"text":347,"correct":26},"上供下回式低压蒸汽供暖系统立管内蒸汽流速为20m\u002Fs",{"key":28,"text":349,"correct":22},"要求控制噪声的室内供暖管道内水流速为1.5m\u002Fs",{"key":31,"text":34,"correct":22},"ACD",{"id":353,"libraryId":5,"type":74,"typeLabel":75,"stem":34,"options":354,"answer":24,"analysis":34},881678,[355,357,359,361],{"key":20,"text":356,"correct":26},"调节阀宜配置在入口供水管上",{"key":24,"text":358,"correct":22},"调节阀必须配置在入口的回水管上",{"key":28,"text":360,"correct":26},"在入口供、回水管上各配置调节阀",{"key":31,"text":362,"correct":26},"不需要配置调节阀",{"id":364,"libraryId":5,"type":74,"typeLabel":75,"stem":365,"options":366,"answer":28,"analysis":34},881679,"下列哪项不属于《绿建标准》中的控制项要求？( )",[367,369,371,373],{"key":20,"text":368,"correct":26},"公共建筑空调供暖系统的冷热源机组能效比符合《公建节能》中第5.4.5，5.4.8，5.4.9条规定",{"key":24,"text":370,"correct":26},"采用集中供暖和(或)集中空调系统的住宅，设置室温调节和热量计量设施",{"key":28,"text":372,"correct":22},"公共建筑通风空调系统风机的单位风量耗功率和冷热水系统的输送能效比符合《公建节能》第5.3.26，5.3.27条的规定",{"key":31,"text":374,"correct":26},"锅炉热效率符合《公建节能》中第5.4.3条规定",{"id":376,"libraryId":5,"type":74,"typeLabel":75,"stem":377,"options":378,"answer":28,"analysis":34},881680,"某栋楼的空调水系统，冷水机组的阻力为100kPa，管道为异程系统，最远环路的阻力最大，其单程长度50m，比摩阻均按150Pa\u002Fm估算，局部阻力为摩擦阻力的50%，过滤器、分集水器等管道附件的阻力为80kPa，最远环路空调末端阻力为43kPa，则循环水泵的扬程应选( )。",[379,381,383,385],{"key":20,"text":380,"correct":26},"24m",{"key":24,"text":382,"correct":26},"26m",{"key":28,"text":384,"correct":22},"28m",{"key":31,"text":386,"correct":26},"30m",{"id":388,"libraryId":5,"type":74,"typeLabel":75,"stem":34,"options":389,"answer":20,"analysis":34},881681,[390,392,394,396],{"key":20,"text":391,"correct":22},"送风口选型与设置不当",{"key":24,"text":393,"correct":26},"送风温度过低",{"key":28,"text":395,"correct":26},"送风温度太高",{"key":31,"text":397,"correct":26},"热负荷太小",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":351,"analysis":34},881682,"冷库中制冷管道的敷设要求，下列哪几项是错误的?( )。",[402,404,406,408],{"key":20,"text":403,"correct":22},"低压侧制冷管道的直管段超过120m，应设置一处管道补偿装置",{"key":24,"text":405,"correct":26},"高压侧制冷管道的直管段超过50m，应设置一处管道补偿装置",{"key":28,"text":407,"correct":22},"当水平敷设的回气管外径大于108mm时，其变径管接头应保证顶部平齐",{"key":31,"text":409,"correct":22},"制冷系统的气液管道穿过建筑楼板、墙体时，均应加套管，套管空隙均应密封",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":422,"analysis":34},881683,"半封闭式制冷压缩机，其内置电动机的绕组必须耐( )。",[414,416,418,420],{"key":20,"text":415,"correct":26},"高温",{"key":24,"text":417,"correct":22},"制冷剂",{"key":28,"text":419,"correct":26},"低温",{"key":31,"text":421,"correct":22},"润滑油","BD",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":58,"analysis":34},881684,"设置于蒸汽加湿器上的自动调节阀，下列哪几项是正确的？",[427,429,431,433],{"key":20,"text":428,"correct":26},"应采用等百分比特性的蒸汽二通阀",{"key":24,"text":430,"correct":26},"当压力损失比小于0.6时，宜采用抛物线特性的蒸汽二通阀",{"key":28,"text":432,"correct":22},"当压力损失比等于0.6时，宜采用线性特性的蒸汽二通阀",{"key":31,"text":434,"correct":22},"当压力损失比大于0.6时，宜采用线性特性的蒸汽二通阀",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":58,"analysis":34},881685,"采用低温送风空调系统时，房间冷负荷除按一般空调系统计算外，还应计入( )。",[439,441,443,445],{"key":20,"text":440,"correct":26},"围护结构散热引起的热负荷",{"key":24,"text":442,"correct":26},"地面传热引起的热负荷",{"key":28,"text":444,"correct":22},"因渗透引起的潜热负荷",{"key":31,"text":446,"correct":22},"因送风机、混合箱风机及风管的得热引起的冷负荷",{"id":448,"libraryId":5,"type":74,"typeLabel":75,"stem":449,"options":450,"answer":28,"analysis":34},881686,"在室内采暖系统中能够实现运行节能的方法，应是下列哪一项？",[451,453,455,457],{"key":20,"text":452,"correct":26},"随着房间热负荷的降低，减小送回水温差",{"key":24,"text":454,"correct":26},"随着房间热负荷的降低，提高供水温度",{"key":28,"text":456,"correct":22},"随着房间热负荷的降低，减少送回水流量",{"key":31,"text":458,"correct":26},"随着房间热负荷的降低，降低回水温度",{"id":460,"libraryId":5,"type":74,"typeLabel":75,"stem":461,"options":462,"answer":24,"analysis":34},881687,"绿色公共建筑采用集中空调系统时，选用的冷水机组的性能系数、能效比相比于《公建节能》中的有关规定值，正确的是( )。",[463,465,467,469],{"key":20,"text":464,"correct":26},"相同",{"key":24,"text":466,"correct":22},"高一个等级",{"key":28,"text":468,"correct":26},"低一个等级",{"key":31,"text":470,"correct":26},"二者无关",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":483,"analysis":34},881688,"关于组合式空调机组的漏风率，正确的表述是( )。",[475,477,479,481],{"key":20,"text":476,"correct":22},"机组的漏风量与额定风量之比",{"key":24,"text":478,"correct":22},"标准空气状态下漏风量与机组的额定风量之比",{"key":28,"text":480,"correct":26},"试验条件下实测的机组漏风量与机组的额定风量之比",{"key":31,"text":482,"correct":26},"额定工况下实测的机组漏风量与机组的额定风量之比","AB",{"id":485,"libraryId":5,"type":74,"typeLabel":75,"stem":486,"options":487,"answer":20,"analysis":34},881689,"单台电动压缩式冷水机组电动机应采用高压供电方式的额定输入功率为( )。",[488,490,492,494],{"key":20,"text":489,"correct":22},"＞1200kW",{"key":24,"text":491,"correct":26},"＞900kW",{"key":28,"text":493,"correct":26},"＞650kW",{"key":31,"text":495,"correct":26},"＞500kW",{"id":497,"libraryId":5,"type":74,"typeLabel":75,"stem":498,"options":499,"answer":24,"analysis":34},881690,"高层建筑的耐火等级分为( )级。",[500,502,504,506],{"key":20,"text":501,"correct":26},"—",{"key":24,"text":503,"correct":22},"二",{"key":28,"text":505,"correct":26},"三",{"key":31,"text":507,"correct":26},"四",{"id":509,"libraryId":5,"type":74,"typeLabel":75,"stem":510,"options":511,"answer":28,"analysis":34},881691,"甲、乙类生产的洁净厂房防火分区的最大允许建筑面积为( )。",[512,514,516,518],{"key":20,"text":513,"correct":26},"2000㎡",{"key":24,"text":515,"correct":26},"3000㎡",{"key":28,"text":517,"correct":22},"单层厂房宜为3000㎡，多层厂房宜为2000㎡",{"key":31,"text":519,"correct":26},"单层厂房宜为2000㎡，多层厂房宜为1000㎡",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":422,"analysis":34},881692,"某空调变流量水系统的末端采用电动两通阀来自动控制水流量。当各末端盘管的设计水流阻力相差较大时，下列哪几项措施是错误的？( )",[524,526,528,530],{"key":20,"text":525,"correct":26},"配置两通电动阀时，在调节要求范围内考虑不同末端的水流阻力差的原因",{"key":24,"text":527,"correct":22},"电动阀之前设置自力式定流量平衡阀",{"key":28,"text":529,"correct":26},"电动阀之前设置手动调节式流量平衡阀",{"key":31,"text":531,"correct":22},"将各电动阀的尺寸尽可能加大，减少各末端支路的不平衡率",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":33,"analysis":34},881693,"为防止围护结构中保温材料的湿度增量超过允许值，应该采取的正确措施是( )。",[536,538,540,542],{"key":20,"text":537,"correct":22},"增大冷凝界面室内侧的蒸汽渗透阻",{"key":24,"text":539,"correct":26},"减小冷凝界面室内侧的蒸汽渗透阻",{"key":28,"text":541,"correct":26},"增大冷凝界面室外侧的蒸汽渗透阻",{"key":31,"text":543,"correct":22},"减小冷凝界面室外侧的蒸汽渗透阻",{"id":545,"libraryId":5,"type":74,"typeLabel":75,"stem":546,"options":547,"answer":31,"analysis":34},881694,"在处理流量、粉尘性质和浓度相同的含尘空气时，旋风除尘器的几何尺寸变化可使其除尘效率提高，( )是错误的。",[548,550,552,554],{"key":20,"text":549,"correct":26},"减小圆筒直径",{"key":24,"text":551,"correct":26},"加长锥体长度",{"key":28,"text":553,"correct":26},"加长圆筒长度",{"key":31,"text":555,"correct":22},"增大排出口直径",{"id":557,"libraryId":5,"type":74,"typeLabel":75,"stem":558,"options":559,"answer":24,"analysis":34},881695,"设置空调控制系统的目的中，不正确的是( )。",[560,562,564,566],{"key":20,"text":561,"correct":26},"提高空调参数的控制精度",{"key":24,"text":563,"correct":22},"减轻操作人员的劳动强度，降低对操作人员的专业素质要求",{"key":28,"text":565,"correct":26},"减少系统运行能耗",{"key":31,"text":567,"correct":26},"提高测试数据的可靠性",{"id":569,"libraryId":5,"type":74,"typeLabel":75,"stem":34,"options":570,"answer":31,"analysis":34},881696,[571,573,575,577],{"key":20,"text":572,"correct":26},"1%",{"key":24,"text":574,"correct":26},"5‰",{"key":28,"text":576,"correct":26},"3‰",{"key":31,"text":578,"correct":22},"1‰",{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":351,"analysis":34},881697,"公共建筑空调选用空气源热泵冷热水机组的原则，正确的应是下列哪几项？( )",[583,585,587,589],{"key":20,"text":584,"correct":22},"较适用于夏热冬冷地区的中、小型公共建筑",{"key":24,"text":586,"correct":26},"夏热冬暖地区选用时，应根据冷负荷选型",{"key":28,"text":588,"correct":22},"寒冷地区冬季运行性能系数低于1.8时，不宜选用",{"key":31,"text":590,"correct":22},"寒冷地区当有集中热源时，不宜选用",{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":195,"analysis":34},881698,"空调系统送风温差的选择中，正确的是( )。",[595,597,599,601],{"key":20,"text":596,"correct":22},"在满足舒适性和工艺要求的前提下，应尽可能加大送风温差",{"key":24,"text":598,"correct":22},"室温控制精度为±0.5℃时，送风温差为5℃",{"key":28,"text":600,"correct":22},"室温控制精度为±1.0℃时，送风温差为8℃",{"key":31,"text":602,"correct":26},"室温控制精度为±2.0℃时，送风口高度为6m，送风温差为9℃",{"id":604,"libraryId":5,"type":74,"typeLabel":75,"stem":605,"options":606,"answer":24,"analysis":34},881699,"蒸发温度与冷凝温度对逆卡诺循环制冷系数的影响程度( )。",[607,609,611,613],{"key":20,"text":608,"correct":26},"蒸发温度＜冷凝温度",{"key":24,"text":610,"correct":22},"蒸发温度＞冷凝温度",{"key":28,"text":612,"correct":26},"蒸发温度一冷凝温度",{"key":31,"text":614,"correct":26},"不确定",{"id":616,"libraryId":5,"type":74,"typeLabel":75,"stem":617,"options":618,"answer":24,"analysis":34},881700,"到目前为止，我国的居住建筑节能设计标准已经涵盖了哪些建筑气候分区？( )",[619,621,623,625],{"key":20,"text":620,"correct":26},"严寒地区、寒冷地区、夏热冬冷地区、夏热冬暖地区、温和地区",{"key":24,"text":622,"correct":22},"严寒地区、寒冷地区、夏热冬冷地区、夏热冬暖地区",{"key":28,"text":624,"correct":26},"严寒地区、寒冷地区、夏热冬冷地区",{"key":31,"text":626,"correct":26},"严寒地区、寒冷地区",[628,631,634,637,640,643],{"id":74,"name":629,"category":7,"favorite":630},"领导干部任职前廉政法规知识测试题",92,{"id":632,"name":633,"category":7,"favorite":74},595,"建筑结构与设备",{"id":635,"name":636,"category":7,"favorite":74},715,"招标采购专业知识与法律法规",{"id":638,"name":639,"category":7,"favorite":74},848,"市政方向-通用基础",{"id":641,"name":642,"category":7,"favorite":8},534,"BIM工程师",{"id":644,"name":642,"category":7,"favorite":8},535]