[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-36":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":626},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,36,50,2054,[13,35,48,61,74,87,100,113,121,134,146,158,169,181,194,206,218,230,242,254,266,278,290,302,312,324,336,348,360,372,385,397,409,421,433,444,456,468,480,492,504,516,528,540,552,564,576,588,600,614],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},881601,2,"多选题","关于密闭罩排风量的计算，下列说法正确的是( )。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","按截面风速计算风速时，取垂直于密闭罩截面的最大风速",false,{"key":24,"text":25,"correct":22},"B","换气次数的多少视有害物质的浓度、罩内工作情况而定，一般有能见度要求时换气次数应增多",{"key":27,"text":28,"correct":29},"C","对于大容积密闭罩按截面风速计算",true,{"key":31,"text":32,"correct":29},"D","密闭罩的排风量一般由两部分组成：一是由运送物料带人罩内的诱导空气量(如物料输送)或工艺设备供给的空气量；另一部分是为了消除罩内正压并保持一定负压所需经孔口或不严密缝隙吸入的空气量","CD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},881602,"关于采暖方式选用热媒的说法，哪几项是不合理的？",[39,41,43,45],{"key":20,"text":40,"correct":29},"热水吊顶辐射板的热媒可采用0.1～0.3MPa的蒸汽",{"key":24,"text":42,"correct":22},"热风采暖的热媒采用0.1～0.3MPa的蒸汽",{"key":27,"text":44,"correct":29},"工业建筑以采暖为主，热媒不宜采用高温热水",{"key":31,"text":46,"correct":22},"防空地下室采暖热媒不宜采用高温热水","AC",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},881603,"洁净室和高效过滤器的密封是确保洁净室洁净度的关键因素之一，常用的密封方法有( )。",[52,54,56,58],{"key":20,"text":53,"correct":29},"固体密封垫(如橡胶板)",{"key":24,"text":55,"correct":29},"液体密封胶",{"key":27,"text":57,"correct":29},"液槽刀口密封",{"key":31,"text":59,"correct":29},"负压泄漏密封","ABCD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},881604,"采暖热水热交换站关于水一水换热器的选择，说法正确的是下列哪几项？",[65,67,69,71],{"key":20,"text":66,"correct":29},"优先选择结构紧凑传热系数高的板式换热器",{"key":24,"text":68,"correct":22},"当供热网一、二次侧水温相差较大时，宜采用不等流道截面的板式换热器",{"key":27,"text":70,"correct":22},"换热器中水流速宜控制在0.2～0.5m\u002Fs",{"key":31,"text":72,"correct":29},"热水供回水温差值不小于5℃","AD",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":86,"analysis":34},881605,"公共建筑允许“采用电热锅炉、电热水器作为直接供暖和空气调节系统的热源”的下列条件中，哪些是错误的？( )",[78,80,82,84],{"key":20,"text":79,"correct":22},"电力充足、供电政策支持和电价优惠地区的建筑",{"key":24,"text":81,"correct":29},"采用蓄热式电锅炉",{"key":27,"text":83,"correct":29},"用煤、油等燃料受到环保或消防严格限制的建筑",{"key":31,"text":85,"correct":29},"内、外区合一的末端变风量系统","BCD",{"id":88,"libraryId":5,"type":15,"typeLabel":16,"stem":89,"options":90,"answer":99,"analysis":34},881606,"报警阀组控制的喷头数应符合的要求是( )。",[91,93,95,97],{"key":20,"text":92,"correct":29},"湿式系统、预作用系统不宜超过800只",{"key":24,"text":94,"correct":29},"于式系统不宜超过500只",{"key":27,"text":96,"correct":29},"报警阀组供水的最高、最低喷头高差不宜超过50m",{"key":31,"text":98,"correct":22},"干式系统不宜超过400只","ABC",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":112,"analysis":34},881607,"蒸汽热力网管道采用地下敷设时，应优先采用下列何种方式?( )。",[104,106,108,110],{"key":20,"text":105,"correct":29},"直埋敷设",{"key":24,"text":107,"correct":29},"不通行管沟敷设",{"key":27,"text":109,"correct":22},"半通行管沟敷设",{"key":31,"text":111,"correct":22},"通行管沟敷设","AB",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":115,"answer":33,"analysis":34},881608,[116,117,118,120],{"key":20,"text":34,"correct":22},{"key":24,"text":34,"correct":22},{"key":27,"text":119,"correct":29},"机械送风量9.6kg\u002Fs",{"key":31,"text":34,"correct":29},{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":133,"analysis":34},881609,"关于得热量的说法，正确的是( )。",[125,127,129,131],{"key":20,"text":126,"correct":29},"得热量中有显热或潜热，或两者兼有",{"key":24,"text":128,"correct":29},"显热得热有两种不同的传递方式",{"key":27,"text":130,"correct":22},"得热量一般等于冷负荷",{"key":31,"text":132,"correct":29},"得热中的辐射成分不能直接被空气吸收","ABD",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":86,"analysis":34},881610,"在( )情况下，应设置集中空调控制系统。",[138,140,142,144],{"key":20,"text":139,"correct":22},"工艺或使用条件对控制有一定要求的情况",{"key":24,"text":141,"correct":29},"系统规模大、设备台数多的情况",{"key":27,"text":143,"correct":29},"系统各部分相距较远、且相互关联的情况",{"key":31,"text":145,"correct":29},"采用集中控制可合理利用能量，实现节能运行的情况",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":133,"analysis":34},881611,"关于湿空气处理过程的表述，下列哪几项是错的？",[150,152,154,156],{"key":20,"text":151,"correct":29},"室内发热量很大且无余湿量，冬季送风温度为15℃，采用干蒸汽加湿可保证室内25℃、60%的参数",{"key":24,"text":153,"correct":29},"北方地区的一次回风系统中，当冬季新风温度太低时，需预热新风后再与回风混合，以防止冻坏加热盘管",{"key":27,"text":155,"correct":22},"空调箱中加设循环水喷淋段，可以在过渡季减少冷机开启时间",{"key":31,"text":157,"correct":29},"直接蒸发冷却获得的最低水温为空气的湿球温度，间接蒸发冷却可以获得低于空气露点温度的水温",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":33,"analysis":34},881612,"为了减少建筑空调能耗，所采取的措施中正确的是( )。",[162,163,165,167],{"key":20,"text":34,"correct":22},{"key":24,"text":164,"correct":22},"像人走灯灭一样，人走空调停",{"key":27,"text":166,"correct":29},"将夏季空调温度设定值由24℃调高到26℃",{"key":31,"text":168,"correct":29},"采用绿色装修材料取代VOC散发量大的装修材料",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":86,"analysis":34},881613,"关于一次回风系统和二次回风系统的叙述正确的是( )。",[173,175,177,179],{"key":20,"text":174,"correct":22},"采用露点送风的一次回风系统，其空调设备夏季的冷风量由室内冷负荷、新风负荷和再热负荷组成",{"key":24,"text":176,"correct":29},"对同一房间采用一次回风系统，在冬季所需的热量与二次回风系统相同",{"key":27,"text":178,"correct":29},"当夏季空调房间需进行再热时，采用二次回风系统可节约再热量",{"key":31,"text":180,"correct":29},"使用表面式换热器与喷水室处理空气的一次回风系统或二次回风系统，在冬季空调设备所需的热量相同",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":193,"analysis":34},881614,"对于进深较大(超过10m)的办公室空调设计，关于内、外区的说法，下列哪几项是错误的？( )",[185,187,189,191],{"key":20,"text":186,"correct":22},"采用变风量全空气系统时，应考虑空调内、外区分区",{"key":24,"text":188,"correct":29},"采用定风量全空气系统时，不应考虑空调内、外区分区",{"key":27,"text":190,"correct":29},"采用风机盘管加新风系统时，不应考虑空调内、外区分区",{"key":31,"text":192,"correct":22},"内、外区是否考虑分区，与上述系统形式无关","BC",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":99,"analysis":34},881615,"根据供回水干管末端压差，变频调速控制空调冷水二级泵，系统环路常出现大流量小温差的现象，不利于空调系统节能。下列哪些分析判断是正确的？",[198,200,202,204],{"key":20,"text":199,"correct":29},"干管末端压差设定值偏大",{"key":24,"text":201,"correct":29},"大部分自控水量调节阀故障，无法关闭",{"key":27,"text":203,"correct":29},"空调箱盘管选型偏小",{"key":31,"text":205,"correct":22},"二次供水温度偏低",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":99,"analysis":34},881616,"下列哪些属于非传统水源？( )",[210,212,214,216],{"key":20,"text":211,"correct":29},"再生水",{"key":24,"text":213,"correct":29},"海水",{"key":27,"text":215,"correct":29},"雨水",{"key":31,"text":217,"correct":22},"地下水",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":60,"analysis":34},881617,"雷诺式调压器的特点是( )。",[222,224,226,228],{"key":20,"text":223,"correct":29},"流量大、性能稳定",{"key":24,"text":225,"correct":29},"调压精度高",{"key":27,"text":227,"correct":29},"调压器阻力损失小",{"key":31,"text":229,"correct":29},"设备庞大",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":99,"analysis":34},881618,"空调设备中，风机的选择应考虑的因素包括( )。",[234,236,238,240],{"key":20,"text":235,"correct":29},"空气的性质",{"key":24,"text":237,"correct":29},"安装场所",{"key":27,"text":239,"correct":29},"风机的性能",{"key":31,"text":241,"correct":22},"风机的体积",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":33,"analysis":34},881619,"采用二次泵的空调冷水系统主要特点，下列哪几项是正确的？",[246,248,250,252],{"key":20,"text":247,"correct":22},"可实现变流量运行，二级泵采用台数控制即可、初投资高、运行能耗低",{"key":24,"text":249,"correct":22},"可实现变流量运行，冷源侧需设旁通管、初投资高、运行能耗较低",{"key":27,"text":251,"correct":29},"可实现变流量运行，冷源侧需设旁通管、初投资高、各支路阻力差异大可实现运行节能",{"key":31,"text":253,"correct":29},"可实现变流量运行，一级泵可采用台数控制，末端装置需采用二通阀，一些情况下并不能实现运行节能",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":133,"analysis":34},881620,"关于制冷机房设计，下列说法正确的是( )。",[258,260,262,264],{"key":20,"text":259,"correct":29},"设计机房时，必须考虑和配置供运输、安装、维修的大门及通道，必要时应设置设备吊装孔，较大型制冷机房的机器间与辅助设备间和水泵间宜分开设置",{"key":24,"text":261,"correct":29},"制冷机房的门窗应朝外开，氨制冷压缩机房设置两个尽量互相远离的出口，其中至少有一个出口直接通向室外",{"key":27,"text":263,"correct":22},"当设有与机器间相邻的值班控制室时，相邻的门应为隔声门，观察窗应为隔声窗，窗台高度宜为0.5m",{"key":31,"text":265,"correct":29},"当采用的制冷剂有毒性时，制冷机房的门不允许直接通向生产性厂房或空调机房",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":133,"analysis":34},881621,"哪些形式的室内机械循环热水供暖系统需要考虑水在散热器和管道中冷却而产生自然作用压力的影响？( )",[270,272,274,276],{"key":20,"text":271,"correct":29},"上供下回垂直双管系统",{"key":24,"text":273,"correct":29},"下供下回垂直双管系统",{"key":27,"text":275,"correct":22},"上供下回垂直单管系统",{"key":31,"text":277,"correct":29},"分层布置的水平单管系统",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":60,"analysis":34},881622,"建筑物内排水管道布置要求( )。",[282,284,286,288],{"key":20,"text":283,"correct":29},"卫生器具至排出管的距离应最短，管道转弯应最少",{"key":24,"text":285,"correct":29},"排水管不得布置在遇水会引起燃烧、爆炸或损坏的原料、产品和设备的上面",{"key":27,"text":287,"correct":29},"排水管道不得敷设在对生产工艺或卫生有特殊要求的生产厂房内，不得穿越食品和贵重商品库房、通风小室、变配电间、电梯机房、烟道和风道下行上给式系统，当人户支管上有分户计量表时，应在各供水立管顶设自动排气阀",{"key":31,"text":289,"correct":29},"排水管道不得穿越设备基础，不宜穿越地基梁",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":99,"analysis":34},881623,"净化空调系统新风口可用采用( )过滤器。",[294,296,298,300],{"key":20,"text":295,"correct":29},"泡沫塑料",{"key":24,"text":297,"correct":29},"合成纤维",{"key":27,"text":299,"correct":29},"玻璃纤维",{"key":31,"text":301,"correct":22},"油浸",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":304,"answer":60,"analysis":34},881624,[305,307,309,310],{"key":20,"text":306,"correct":29},"控制点至罩口距离X",{"key":24,"text":308,"correct":29},"罩口面积F",{"key":27,"text":34,"correct":29},{"key":31,"text":311,"correct":29},"集气吸气罩的形式",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":60,"analysis":34},881625,"公共建筑本专业施工图的设备表中，需注明所选用风机性能参数的应是哪几项？",[316,318,320,322],{"key":20,"text":317,"correct":29},"风机全压",{"key":24,"text":319,"correct":29},"风机最低总效率",{"key":27,"text":321,"correct":29},"风机风量",{"key":31,"text":323,"correct":29},"风机的配套电机功率",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":86,"analysis":34},881626,"关于降低系统噪声措施的说法中，正确的是( )。",[328,330,332,334],{"key":20,"text":329,"correct":22},"降低噪声最有效的措施是安装消声器",{"key":24,"text":331,"correct":29},"风管上的调节阀不仅会增加阻力，而且会增加噪声，应尽量少装",{"key":27,"text":333,"correct":29},"风管急剧拐弯会产生二次噪声",{"key":31,"text":335,"correct":29},"由于噪声可以通过固体接触传播，因此与电视演播室相邻的空调机房应设置独立基础",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":112,"analysis":34},881627,"关于事故排风的排风口，下列符合规定的是( )。",[340,342,344,346],{"key":20,"text":341,"correct":29},"不应布置在人员经常停留或经常通行的地点",{"key":24,"text":343,"correct":29},"排风口不得朝向室外空气动力阴影区和正压区",{"key":27,"text":345,"correct":22},"当排气中含有可燃气体时，事故通风系统排风口距可能火花溅落地点应大于10.m",{"key":31,"text":347,"correct":22},"排风口与机械送风系统的进风口的水平距离不应小于10m",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":86,"analysis":34},881628,"对于自然通风进风口的设计，下列哪几项要求是错误的？( )",[352,354,356,358],{"key":20,"text":353,"correct":22},"进风口下缘距室内地面的高度不宜大于1.2m",{"key":24,"text":355,"correct":29},"进风口应远离室外污染源5m以上",{"key":27,"text":357,"correct":29},"冬季进风口下缘距室内地面的高度小于3m时，宜采取防止冷风吹向人员活动区的措施",{"key":31,"text":359,"correct":29},"冬季进风口下缘距室内地面的高度小于4m时，应采取防止冷风吹向人员活动区的措施",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":133,"analysis":34},881629,"关于热电厂集中供热的方式的表述，哪几项是正确的？",[364,366,368,370],{"key":20,"text":365,"correct":29},"供热汽轮机的形式和容量，应根据外部热负荷的大小和特征选择",{"key":24,"text":367,"correct":29},"凝汽式汽轮机改装为供热汽轮机，一般会使原发电厂发电功率下降25%左右",{"key":27,"text":369,"correct":22},"背压式汽轮机排气压力等于大气压力",{"key":31,"text":371,"correct":29},"抽汽背压式汽轮机既能供应采暖热水，又能供应工业用蒸汽",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":384,"analysis":34},881630,"建筑利用自然通风，相对应的室外常年风速的哪几项可获得一定的风压作用？",[376,378,380,382],{"key":20,"text":377,"correct":29},"冬季常年风速为3.5m\u002Fs的平均风速",{"key":24,"text":379,"correct":22},"夏季常年风速为1.5m\u002Fs的平均风速",{"key":27,"text":381,"correct":29},"夏季常年风速为3.5m\u002Fs的平均风速",{"key":31,"text":383,"correct":29},"冬季常年风速为4.Om\u002Fs的平均风速","ACD",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":133,"analysis":34},881631,"设水泵和水箱的给水方式的优点是( )。",[389,391,393,395],{"key":20,"text":390,"correct":29},"水泵出水量稳定，能保证在高效区运行",{"key":24,"text":392,"correct":29},"系统水压稳定",{"key":27,"text":394,"correct":22},"设置位置灵活，可设在高处也可设在低处",{"key":31,"text":396,"correct":29},"高位水箱贮存调节容积，可起到调节作用",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":47,"analysis":34},881632,"下列有关风管设计的要求，正确的是( )。",[401,403,405,407],{"key":20,"text":402,"correct":29},"丙类厂房的送、排风管宜分层设置",{"key":24,"text":404,"correct":22},"甲、乙类厂房的风管不得穿过其他房间",{"key":27,"text":406,"correct":29},"排除有爆炸危险和剧毒物质的排风管的正压段不得穿过其他房间",{"key":31,"text":408,"correct":22},"排除密度小于空气的可燃气体的管道应沿气流方向有不小于0.003的上倾坡度",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":133,"analysis":34},881633,"供暖系统排气措施正确的是( )。",[413,415,417,419],{"key":20,"text":414,"correct":29},"下行上给式热水供暖系统，在顶层散热器上装排气阀",{"key":24,"text":416,"correct":29},"下进下出式水平单管串联系统在每组散热器上装排气阀",{"key":27,"text":418,"correct":22},"机械循环热水干管尽量低头走",{"key":31,"text":420,"correct":29},"蒸汽供暖系统干式回水时由凝结水管的末端集中排气",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":99,"analysis":34},881634,"建筑室内给水系统根据运行机理应设置止回阀，关于设置的目的和部位，下列哪几项是正确的？( )",[425,427,429,431],{"key":20,"text":426,"correct":29},"水泵出水管，防止停泵水倒流",{"key":24,"text":428,"correct":29},"密闭的水加热器进水管，防止热水进入给水系统",{"key":27,"text":430,"correct":29},"高位水箱，当进出水干管合一时，安装在出水支管上，保证进出水的正确流程",{"key":31,"text":432,"correct":22},"供水管接到便器洗管处，防止水倒流污染给水系统",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":435,"answer":193,"analysis":34},881635,[436,438,440,442],{"key":20,"text":437,"correct":22},"水泵的设计扬程不够",{"key":24,"text":439,"correct":29},"水泵的设计流量不够",{"key":27,"text":441,"correct":29},"热水系统的设计阻力过小",{"key":31,"text":443,"correct":22},"水泵性能未达到要求",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":455,"analysis":34},881636,"夏季采用冷却除湿的风机盘管十新风空调系统，下列哪几项说法是正确的？",[448,450,452,454],{"key":20,"text":449,"correct":22},"新风处理到室内空气等焓线，风机盘管不承担新风引起的任何空调负荷",{"key":24,"text":451,"correct":29},"新风处理到室内空气等含湿量线，风机盘管承担室内湿负荷和部分室内冷负荷",{"key":27,"text":453,"correct":22},"风机盘管水侧采用电动温控阀控制",{"key":31,"text":34,"correct":29},"BD",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":86,"analysis":34},881637,"下列关于空调冷热源的说法，正确的是( )。",[460,462,464,466],{"key":20,"text":461,"correct":22},"直燃式冷热水机组比螺杆式冷水机组节能，因此燃气空调对环境的影响较小",{"key":24,"text":463,"correct":29},"在相同的设计条件下，地下水水源热泵冷热水机组的能耗可能比空气源热泵冷热水机组大",{"key":27,"text":465,"correct":29},"夏季冷负荷和冬季热负荷相差较大的建筑，不宜设置地耦型热泵空调系统",{"key":31,"text":467,"correct":29},"电蓄热锅炉的一次能源消耗比燃煤锅炉大，因此其环境污染比燃煤锅炉大",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":193,"analysis":34},881638,"外窗增加低辐射膜(Low-e膜)的效果中，下列说法错误的是( )。",[472,474,476,478],{"key":20,"text":473,"correct":22},"减少冬季太阳辐射得热",{"key":24,"text":475,"correct":29},"增加夏季太阳辐射得热",{"key":27,"text":477,"correct":29},"使反射长波辐射的能力减小",{"key":31,"text":479,"correct":22},"增大外窗的传热热阻",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":384,"analysis":34},881639,"在1000kg的空气(20℃，60%)中加入1000kJ的热量和2kg的水蒸气，则空气最终的状态参数为( )。",[484,486,488,490],{"key":20,"text":485,"correct":29},"焓值48.45kj\u002Fkg",{"key":24,"text":487,"correct":22},"相对湿度100%",{"key":27,"text":489,"correct":29},"含湿量10.72g\u002Fkg",{"key":31,"text":491,"correct":29},"干球温度21℃",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":99,"analysis":34},881640,"围护结构温差修正系数口值的大小取决于( )。",[496,498,500,502],{"key":20,"text":497,"correct":29},"非供暖房间或空间墙体的热惰性",{"key":24,"text":499,"correct":29},"非供暖房间或空间窗户的气密性",{"key":27,"text":501,"correct":29},"非供暖房间或空间所在建筑物的层高",{"key":31,"text":503,"correct":22},"室外气象条件",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":133,"analysis":34},881641,"关于在定压点设置，正确的选项是( )。",[508,510,512,514],{"key":20,"text":509,"correct":29},"两个承压相同水温不同的独立水系统可以采用同一个膨胀水箱定压",{"key":24,"text":511,"correct":29},"屋顶空气源热泵冷水机组的定压点应设置在水泵的入口",{"key":27,"text":513,"correct":22},"定压点不能设置在冷水机组的出口",{"key":31,"text":515,"correct":29},"膨胀水箱膨胀管的长短不影响系统水压分布",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":133,"analysis":34},881642,"属于第一分区的地区是( )。",[520,522,524,526],{"key":20,"text":521,"correct":29},"黑龙江",{"key":24,"text":523,"correct":29},"吉林",{"key":27,"text":525,"correct":22},"天津",{"key":31,"text":527,"correct":29},"陕西偏北部分",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":530,"options":531,"answer":99,"analysis":34},881643,"采用加压系统回收凝结水时要符合一定条件，下列哪几项是正确的？( )",[532,534,536,538],{"key":20,"text":533,"correct":29},"凝结水泵应设置自动启停装置",{"key":24,"text":535,"correct":29},"水泵宜设置2台，其1台备用",{"key":27,"text":537,"correct":29},"泵的扬程应能克服凝结水系统的压力损失、泵站至凝结水箱的提升高度和凝结水箱的压力",{"key":31,"text":539,"correct":22},"用疏水加压器代替凝结水泵，可直接连接到各用汽设备的凝结水管道上",{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":384,"analysis":34},881644,"通风机安装应符合有关规定，下列哪几项是正确的？( )",[544,546,548,550],{"key":20,"text":545,"correct":29},"型号规格应符合设计规定，其出口方向应正确",{"key":24,"text":547,"correct":22},"叶轮旋转应平稳，停转后应每次停留在同一位置",{"key":27,"text":549,"correct":29},"固定通风机的地脚螺栓应拧紧，并有防松动措施",{"key":31,"text":551,"correct":29},"通风机传动装置的外露部位以及直通大气的进出口，必须装设防护罩(网)或采取安全措施",{"id":553,"libraryId":5,"type":15,"typeLabel":16,"stem":554,"options":555,"answer":112,"analysis":34},881645,"某空调冷水系统采用两台蒸汽压缩式冷水机组，配置的一次定流量循环水泵，冷却水泵与冷却塔并联运行。当因气候变化，部分负荷运行时，仅有一台机组与其相匹配的水泵等运行。实现节能，并保障运行合理的做法应是下列哪几项？",[556,558,560,562],{"key":20,"text":557,"correct":29},"关闭不运行冷水机组的冷却水进机组管路阀门",{"key":24,"text":559,"correct":29},"关闭不运行冷水机组的冷水进机组管路阀门",{"key":27,"text":561,"correct":22},"始终使冷却水通过两台冷却塔实现冷却",{"key":31,"text":563,"correct":22},"两台冷却塔的风机保持全部运行",{"id":565,"libraryId":5,"type":15,"typeLabel":16,"stem":566,"options":567,"answer":133,"analysis":34},881646,"对于放散热或有害物质的生产设备，下列布置原则正确的是( )。",[568,570,572,574],{"key":20,"text":569,"correct":29},"布置在同一建筑内毒性大和毒性小的设备应隔开",{"key":24,"text":571,"correct":29},"应布置在厂房自然通风的排气天窗下部",{"key":27,"text":573,"correct":22},"应集中布置在多层厂房内的顶层",{"key":31,"text":575,"correct":29},"因工艺要求布置在多层厂房下层时，应采取有效措施防止对上层空气的污染",{"id":577,"libraryId":5,"type":15,"typeLabel":16,"stem":578,"options":579,"answer":455,"analysis":34},881647,"锅炉房设计中，在利用锅炉产生的各种余热时，应符合下列哪几项规定?( )。",[580,582,584,586],{"key":20,"text":581,"correct":22},"散热器供暖系统宜设烟气余热回收装置",{"key":24,"text":583,"correct":29},"有条件时应选用冷凝式燃气锅炉",{"key":27,"text":585,"correct":22},"选用普通锅炉时，应设烟气余热回收装置",{"key":31,"text":587,"correct":29},"热媒热水温度不高于60℃的低温供热系统，应设烟气余热回收装置",{"id":589,"libraryId":5,"type":15,"typeLabel":16,"stem":590,"options":591,"answer":455,"analysis":34},881648,"下列关于住宅厨房暖通设计的措施，正确的是( )。",[592,594,596,598],{"key":20,"text":593,"correct":22},"设置集中供暖系统住宅的厨房，室内供暖计算温度与楼梯间及走廊相同",{"key":24,"text":595,"correct":29},"无外窗的厨房应有通风措施且预留安装排风机的位置",{"key":27,"text":597,"correct":22},"应首先采用通过外墙直接排放的方式排除烹饪油烟",{"key":31,"text":599,"correct":29},"当采用竖向通风道时应采用防止支管回流和竖井泄漏的措施",{"id":601,"libraryId":5,"type":602,"typeLabel":603,"stem":604,"options":605,"answer":20,"analysis":34},881649,1,"单选题","某飞机修理库房高20m，采用地板辐射供暖，其高度附加率应为( )。",[606,608,610,612],{"key":20,"text":607,"correct":29},"8%",{"key":24,"text":609,"correct":22},"15%",{"key":27,"text":611,"correct":22},"16%",{"key":31,"text":613,"correct":22},"32%",{"id":615,"libraryId":5,"type":602,"typeLabel":603,"stem":616,"options":617,"answer":31,"analysis":34},881650,"某车间设置处理含氨气的排风系统，净化设备为填料塔，不可采用的吸收剂为( )。",[618,620,622,624],{"key":20,"text":619,"correct":22},"水",{"key":24,"text":621,"correct":22},"硫酸",{"key":27,"text":623,"correct":22},"乙二醛",{"key":31,"text":625,"correct":29},"苛性钠",[627,630,633,636,639,642],{"id":602,"name":628,"category":7,"favorite":629},"领导干部任职前廉政法规知识测试题",92,{"id":631,"name":632,"category":7,"favorite":602},595,"建筑结构与设备",{"id":634,"name":635,"category":7,"favorite":602},715,"招标采购专业知识与法律法规",{"id":637,"name":638,"category":7,"favorite":602},848,"市政方向-通用基础",{"id":640,"name":641,"category":7,"favorite":8},534,"BIM工程师",{"id":643,"name":641,"category":7,"favorite":8},535]