[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-35":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":613},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,35,50,2054,[13,29,41,53,65,77,89,101,113,125,137,149,161,173,185,197,209,221,233,245,257,269,281,293,305,316,324,336,347,358,370,382,394,406,418,430,445,458,471,484,491,504,516,528,541,554,566,578,590,601],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":25,"analysis":17},881551,1,"单选题","",[19,22,24,27],{"key":20,"text":17,"correct":21},"A",false,{"key":23,"text":17,"correct":21},"B",{"key":25,"text":17,"correct":26},"C",true,{"key":28,"text":17,"correct":21},"D",{"id":30,"libraryId":5,"type":15,"typeLabel":16,"stem":31,"options":32,"answer":25,"analysis":17},881552,"防烟分区内排烟口距最远点水平距离( )。",[33,35,37,39],{"key":20,"text":34,"correct":21},"未作规定",{"key":23,"text":36,"correct":21},"不应超过20m",{"key":25,"text":38,"correct":26},"不应超过30m",{"key":28,"text":40,"correct":21},"不应超过40m",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":23,"analysis":17},881553,"离心式冷水机组被广泛用于大型系统中，在大冷量时效率高，机构紧凑，但负荷降低到( )以下时，有发生喘振的危险。",[45,47,49,51],{"key":20,"text":46,"correct":21},"10%～20%",{"key":23,"text":48,"correct":26},"20%～30%",{"key":25,"text":50,"correct":21},"30%～40%",{"key":28,"text":52,"correct":21},"40%～50%",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":28,"analysis":17},881554,"风管与通风机连接处采用柔性接头的长度宜为( )。",[57,59,61,63],{"key":20,"text":58,"correct":21},"80～100mm",{"key":23,"text":60,"correct":21},"100～150mm",{"key":25,"text":62,"correct":21},"200～250mm",{"key":28,"text":64,"correct":26},"150～300mm",{"id":66,"libraryId":5,"type":15,"typeLabel":16,"stem":67,"options":68,"answer":28,"analysis":17},881555,"冷库冷负荷的计算，下列哪一项是正确的？( )",[69,71,73,75],{"key":20,"text":70,"correct":21},"围护结构热流、食品及其包装和运输工具的热流、通风换气热流、照明热流",{"key":23,"text":72,"correct":21},"围护结构热流、食品热流、通风换气热流、照明及其人员形成的操作热流",{"key":25,"text":74,"correct":21},"围护结构热流、食品及其包装和运输工具的热流、通风换气热流、人员热流",{"key":28,"text":76,"correct":26},"围护结构热流、照明及其人员形成的操作热流、通风换气热流、食品及其包装和运输工具的热流",{"id":78,"libraryId":5,"type":15,"typeLabel":16,"stem":79,"options":80,"answer":25,"analysis":17},881556,"关于蒸汽压缩制冷循环的说法，下列哪一项是错误的？",[81,83,85,87],{"key":20,"text":82,"correct":21},"蒸汽压缩制冷性能系数与蒸发温度和冷凝温度有关，也与制冷剂种类有关",{"key":23,"text":84,"correct":21},"在冷凝器后增加再冷却器的再冷循环可以提高制冷系数的性能系数",{"key":25,"text":86,"correct":26},"制冷剂蒸汽被压缩冷凝为液体后，再用制冷剂液体泵提升压力，与直接用压缩机压缩到该压力的电功消耗量相同",{"key":28,"text":88,"correct":21},"工作在相同蒸发温度和冷凝温度的一次节流完全中间冷却的双极压缩制冷循环较单级制冷循环的性能系数大",{"id":90,"libraryId":5,"type":15,"typeLabel":16,"stem":91,"options":92,"answer":20,"analysis":17},881557,"工业热力站中，凝结水箱的总贮水量一般按( )计算。",[93,95,97,99],{"key":20,"text":94,"correct":26},"10～20min最大回水计算",{"key":23,"text":96,"correct":21},"30～50min最大回水计算",{"key":25,"text":98,"correct":21},"10～20min回水计算",{"key":28,"text":100,"correct":21},"10～20min最小回水计算",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":28,"analysis":17},881558,"在除尘系统设计时应根据所处理粉尘的性质选择除尘器，( )是错误的。",[105,107,109,111],{"key":20,"text":106,"correct":21},"处理木材加工粉尘时选用旋风除尘器",{"key":23,"text":108,"correct":21},"处理有回收价值的干物料粉尘时选用布袋除尘器",{"key":25,"text":110,"correct":21},"处理湿度较大粉尘时选用湿式除尘器",{"key":28,"text":112,"correct":26},"处理高比电阻粉尘时选用静电除尘器",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":115,"options":116,"answer":25,"analysis":17},881559,"低温热水地面辐射供暖的辐射传热量与下列哪些因素有关？( )",[117,119,121,123],{"key":20,"text":118,"correct":21},"地表面平均温度、室内空气温度",{"key":23,"text":120,"correct":21},"热媒供回水平均温度、室内非加热表面的面积加权平均温度",{"key":25,"text":122,"correct":26},"地表面平均温度、室内非加热表面的面积加权平均温度",{"key":28,"text":124,"correct":21},"热媒供回水平均温度、地表面平均温度、室内空气温度、室内非加热表面的面积加权平均温度",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":23,"analysis":17},881560,"下列采暖建筑的热负荷计算方法错误的是( )。",[129,131,133,135],{"key":20,"text":130,"correct":21},"风力附加只对不避风的垂直外围结构基本耗热量上进行附加，但对其斜屋面也应在垂直投影面的基本耗热量上进行附加",{"key":23,"text":132,"correct":26},"工业建筑渗透冷空气耗热量附加率是指占其全部外围结构基本耗热量的百分率",{"key":25,"text":134,"correct":21},"多层建筑的渗透冷空气耗热量，当无相关数据时，可按规定的换气次数进行估算",{"key":28,"text":136,"correct":21},"外门附加率只适用于短时间开启的、无热风幕的外门",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":28,"analysis":17},881561,"机械循环热水供暖系统的重力循环作用压力与下列哪个因素无关？( )",[141,143,145,147],{"key":20,"text":142,"correct":21},"供回水温度",{"key":23,"text":144,"correct":21},"供回水密度",{"key":25,"text":146,"correct":21},"散热器距热源的垂直距离",{"key":28,"text":148,"correct":26},"系统作用半径",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":28,"analysis":17},881562,"下列关于文丘里除尘器的描述中哪项是错误的？( )",[153,155,157,159],{"key":20,"text":154,"correct":21},"是一种湿式除尘器",{"key":23,"text":156,"correct":21},"运行时空气压力损失很大",{"key":25,"text":158,"correct":21},"具有较高的净化效率",{"key":28,"text":160,"correct":26},"适合处理大流量含尘气体",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":28,"analysis":17},881563,"测量断面应尽量选择在气流平稳的直管段上，下列要求错误的是( )。",[165,167,169,171],{"key":20,"text":166,"correct":21},"当测量断面设在弯头、三通等异形部件前面时，距这些部件的距离应大于2倍管道直径",{"key":23,"text":168,"correct":21},"当测量断面设在弯头、三通等异形部件后面时，距这些部件的距离应大于4～5倍管道直径",{"key":25,"text":170,"correct":21},"测量断面位置距异形部件的最小距离至少是管道直径的1.5倍",{"key":28,"text":172,"correct":26},"测量断面位置距前面异形部件的最小距离至少是管道直径的1.0倍",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":25,"analysis":17},881564,"热水供暖室外管网的水力失调度是指( )。",[177,179,181,183],{"key":20,"text":178,"correct":21},"室外管网的许用压差与热用户系统的压力损失的比值",{"key":23,"text":180,"correct":21},"热用户系统的压力损失与室外管网的许用压差的比值",{"key":25,"text":182,"correct":26},"热用户的实际流量与规定流量的比值",{"key":28,"text":184,"correct":21},"热用户的规定流量与实际流量的比值",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":23,"analysis":17},881565,"大型暖风机的设计，下列哪一项是正确的？( )",[189,191,193,195],{"key":20,"text":190,"correct":21},"暖风机应沿着车间宽度方向布置",{"key":23,"text":192,"correct":26},"气流射程不应小于车间供暖区长度，在射程区域内不应有高大设备",{"key":25,"text":194,"correct":21},"吸风口底部距地面高度1.5m",{"key":28,"text":196,"correct":21},"在射程区域内有高大设备时，气流射程可小于车间供暖区长度",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":25,"analysis":17},881566,"考虑冷媒管道长度造成的性能衰减后，多联机空调系统制冷工况下满负荷性能系数不应低于( )。",[201,203,205,207],{"key":20,"text":202,"correct":21},"2.6",{"key":23,"text":204,"correct":21},"2.7",{"key":25,"text":206,"correct":26},"2.8",{"key":28,"text":208,"correct":21},"3.0",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":28,"analysis":17},881567,"同时放散有害物质、余热和余湿的生产车间，其全面通风系统风量应按( )。",[213,215,217,219],{"key":20,"text":214,"correct":21},"排除有害物质所需风量计算",{"key":23,"text":216,"correct":21},"排除余热和余湿所需风量计算",{"key":25,"text":218,"correct":21},"排除有害物愿、余热和余湿所需风量之和计算",{"key":28,"text":220,"correct":26},"排除有害物质、余热、余湿中所需风量最大者计算",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":23,"analysis":17},881568,"关于散热器设计，下列说法错误的是( )。",[225,227,229,231],{"key":20,"text":226,"correct":21},"其他条件相同时，同侧上进下出最有利",{"key":23,"text":228,"correct":26},"柱型散热器面积可比计算值小0.15㎡",{"key":25,"text":230,"correct":21},"翼型或其他散热器的散热面积可比计算值小5%",{"key":28,"text":232,"correct":21},"表面涂调和漆的散热器比涂铝粉散热器传热系数高",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":20,"analysis":17},881569,"《公建节能》中的IPLV指标是( )。",[237,239,241,243],{"key":20,"text":238,"correct":26},"单台冷水机组部分负荷的综合能效评价指标",{"key":23,"text":240,"correct":21},"多台冷水机组部分负荷的综合能效评价指标",{"key":25,"text":242,"correct":21},"空调系统部分负荷的综合能效评价指标",{"key":28,"text":244,"correct":21},"空调系统夏季部分负荷的综合能效评价指标",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":28,"analysis":17},881570,"采用喷水室处理空气，不能实现的处理过程应是下列哪一项？",[249,251,253,255],{"key":20,"text":250,"correct":21},"实现等焓加湿过程",{"key":23,"text":252,"correct":21},"实现等温加湿过程",{"key":25,"text":254,"correct":21},"实现降温减湿过程",{"key":28,"text":256,"correct":26},"实现等湿加热过程",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":20,"analysis":17},881571,"溴化锂水溶液，在～定温度下的溶液面上的水蒸气饱和分压力小于纯水的饱和压力，而且浓度越高，液面上水蒸气饱和分压力( )。",[261,263,265,267],{"key":20,"text":262,"correct":26},"越小",{"key":23,"text":264,"correct":21},"越大",{"key":25,"text":266,"correct":21},"不变",{"key":28,"text":268,"correct":21},"不确定",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":28,"analysis":17},881572,"因制冷剂R22润滑油有一定相容性，在设计制冷管路系统时应注意下列哪一项问题？",[273,275,277,279],{"key":20,"text":274,"correct":21},"不必考虑润滑油问题",{"key":23,"text":276,"correct":21},"应考虑满液式蒸发器回油和压缩机出口润滑油分离问题",{"key":25,"text":278,"correct":21},"应考虑压缩机吸气管回油问题",{"key":28,"text":280,"correct":26},"应考虑蒸发器、压缩机吸气管回油和压缩机出口润滑油分离问题",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":23,"analysis":17},881573,"采用干式凝结水管的低压蒸汽供暖系统，下列哪个因素影响凝结水管排空气口与锅炉的高差？( )",[285,287,289,291],{"key":20,"text":286,"correct":21},"蒸汽流速",{"key":23,"text":288,"correct":26},"蒸汽压力",{"key":25,"text":290,"correct":21},"凝结水管坡度",{"key":28,"text":292,"correct":21},"凝结水管长度",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":23,"analysis":17},881574,"在确定建筑的通风方式时，下列哪项要求是错误的？( )",[297,299,301,303],{"key":20,"text":298,"correct":21},"应首先考虑采用自然通风的可能性",{"key":23,"text":300,"correct":26},"是否能采用自然通风取决于室外空气污染情况",{"key":25,"text":302,"correct":21},"当自然通风不能满足要求时应采用机械通风",{"key":28,"text":304,"correct":21},"当自然通风不能满足要求时也可采用自然通风与机械通风结合的复合通风",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":307,"answer":25,"analysis":17},881575,[308,310,312,314],{"key":20,"text":309,"correct":21},"410～420kg\u002Fh",{"key":23,"text":311,"correct":21},"330～340kg\u002Fh",{"key":25,"text":313,"correct":26},"580～590kg\u002Fh",{"key":28,"text":315,"correct":21},"660～670kg\u002Fh",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":20,"analysis":17},881576,"寒冷地区的某旅馆建筑全年设置集中空调系统，拟采用直燃机。问：直燃机选型时，正确的是何项?( )。",[320,321,322,323],{"key":20,"text":17,"correct":26},{"key":23,"text":17,"correct":21},{"key":25,"text":17,"correct":21},{"key":28,"text":17,"correct":21},{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":28,"analysis":17},881577,"根据规范规定燃气锅炉房的火灾危险性分类，下列表述何项是正确的?( )。",[328,330,332,334],{"key":20,"text":329,"correct":21},"锅炉间和燃气调压间应属于甲类生产厂房",{"key":23,"text":331,"correct":21},"锅炉间和燃气调压间应属于乙类生产厂房",{"key":25,"text":333,"correct":21},"锅炉间应属于丙类生产厂房，燃气调压间应属于乙类生产厂房",{"key":28,"text":335,"correct":26},"锅炉间应属于丁类生产厂房，燃气调压间应属于甲类生产厂房",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":338,"answer":28,"analysis":17},881578,[339,341,343,345],{"key":20,"text":340,"correct":21},"由于跨越管段的分流，小于顺序式系统",{"key":23,"text":342,"correct":21},"与顺序式系统相同",{"key":25,"text":344,"correct":21},"大于顺序式系统",{"key":28,"text":346,"correct":26},"经计算才可确定",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":349,"answer":20,"analysis":17},881579,[350,352,354,356],{"key":20,"text":351,"correct":26},"供、回水干管的平均比摩阻降低",{"key":23,"text":353,"correct":21},"供、回水干管的平均比摩阻增加",{"key":25,"text":355,"correct":21},"供、回水干管的平均比摩阻不变",{"key":28,"text":357,"correct":21},"各用户的资用压差均增加。",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":28,"analysis":17},881580,"下列关于空调器选择的说法中，正确的是( )。",[362,364,366,368],{"key":20,"text":363,"correct":21},"空调器的能效比越低，价格越低，因此经济性越好",{"key":23,"text":365,"correct":21},"空调器的能效比越高越节能，因此应尽可能选择高能效比的空调器",{"key":25,"text":367,"correct":21},"空调器的能效比越高，运行费用越少，综合考虑，选择高能效比的空调器更省钱",{"key":28,"text":369,"correct":26},"在一定的使用条件下，采用高能效比的空调器可能并不节能",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":25,"analysis":17},881581,"应用于相关工艺过程，外部吸气罩控制点的最小控制风速，哪一项是错误的？",[374,376,378,380],{"key":20,"text":375,"correct":21},"铸造车间清理滚筒：2.5～10m\u002Fs",{"key":23,"text":377,"correct":21},"焊接工作台：0.5～1.0m\u002Fs",{"key":25,"text":379,"correct":26},"往输送器上给粉料：0.5～0.8m\u002Fs",{"key":28,"text":381,"correct":21},"有液体蒸发的镀槽：0.25～0.5m\u002Fs",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":20,"analysis":17},881582,"采用蒸发冷却空调系统的原则，下列哪一项是错误的？( )",[386,388,390,392],{"key":20,"text":387,"correct":26},"在满足使用要求的前提下，夏季空气调节室外计算湿球温度较低的地区宜采用蒸发冷却空调系统",{"key":23,"text":389,"correct":21},"新疆地区宜采用蒸发冷却空调系统",{"key":25,"text":391,"correct":21},"西北地区宜采用蒸发冷却空调系统，理论计算送风温度绝大多数在16～20℃之间",{"key":28,"text":393,"correct":21},"贵州地区宜采用三级蒸发冷却空调系统",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":28,"analysis":17},881583,"与膨胀水箱连接的( )管路上要设置阀门。",[398,400,402,404],{"key":20,"text":399,"correct":21},"膨胀管",{"key":23,"text":401,"correct":21},"循环管",{"key":25,"text":403,"correct":21},"溢流管",{"key":28,"text":405,"correct":26},"信号管",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":20,"analysis":17},881584,"重力循环系统的自然作用压头应取下列哪个值？( )",[410,412,414,416],{"key":20,"text":411,"correct":26},"设计供回水温度条件下的自然作用压头",{"key":23,"text":413,"correct":21},"供暖期室外平均温度条件下的自然作用压头",{"key":25,"text":415,"correct":21},"设计供回水温度条件下的自然作用压头的2\u002F3",{"key":28,"text":417,"correct":21},"供暖期室外平均温度条件下的自然作用压头的2倍",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":23,"analysis":17},881585,"装配式冷库实际采用隔热层材料导热系数数值应为下列哪一项？( )",[422,424,426,428],{"key":20,"text":423,"correct":21},"≤0.018W\u002F(m·K)",{"key":23,"text":425,"correct":26},"≤0.023W\u002F(m·K)",{"key":25,"text":427,"correct":21},"≤0.040W\u002F(m·K)",{"key":28,"text":429,"correct":21},"≤0.045W\u002F(m·K)",{"id":431,"libraryId":5,"type":432,"typeLabel":433,"stem":434,"options":435,"answer":444,"analysis":17},881586,2,"多选题","某建筑高度为23m的旅馆，应设机械防烟措施的是( )。",[436,438,440,442],{"key":20,"text":437,"correct":26},"不能天然采光和自然通风的封闭楼梯间",{"key":23,"text":439,"correct":26},"设置自然排烟设施的防烟楼梯间，其不具备自然排烟条件的前室",{"key":25,"text":441,"correct":26},"不具备自然排烟条件的消防电梯间前室",{"key":28,"text":443,"correct":26},"不具备自然排烟条件的防烟楼梯间","ABCD",{"id":446,"libraryId":5,"type":432,"typeLabel":433,"stem":447,"options":448,"answer":457,"analysis":17},881587,"按照《公建节能》的规定，当进行围护结构热工性能的权衡判断时，“参照建筑”是指( )。",[449,451,453,455],{"key":20,"text":450,"correct":21},"与所设计建筑性质和规模相近的其他节能建筑",{"key":23,"text":452,"correct":26},"形状、大小、朝向、内部的空间划分和使用功能与所设计建筑完全一致的假想建筑",{"key":25,"text":454,"correct":21},"作为比较能耗的基础的20世纪80年代初期建造的公共建筑",{"key":28,"text":456,"correct":26},"每面外墙均应按比例缩小、每个窗户和屋顶透明部分的面积均应按比例缩小，使建筑的体形系数、窗墙面积比和屋顶透明部分的面积符合本标准的建筑计算模型","BD",{"id":459,"libraryId":5,"type":432,"typeLabel":433,"stem":460,"options":461,"answer":470,"analysis":17},881588,"关于分层空调的说法中，正确的是( )。",[462,464,466,468],{"key":20,"text":463,"correct":21},"采用全空气空调系统才能实现分层空调",{"key":23,"text":465,"correct":21},"分层空调在冬季运行时也可以达到与夏季一样的分层空调效果",{"key":25,"text":467,"correct":26},"分层空调可以减少空调投资",{"key":28,"text":469,"correct":26},"分层空调可以减少空调能耗","CD",{"id":472,"libraryId":5,"type":432,"typeLabel":433,"stem":473,"options":474,"answer":483,"analysis":17},881589,"下列哪几项改变风机特性的方法是正确的？( )",[475,477,479,481],{"key":20,"text":476,"correct":26},"改变通风机转速",{"key":23,"text":478,"correct":26},"改变通风机进口导流叶片角度",{"key":25,"text":480,"correct":21},"调节通风机吸入口阀门",{"key":28,"text":482,"correct":21},"改变管网特性曲线","AB",{"id":485,"libraryId":5,"type":432,"typeLabel":433,"stem":17,"options":486,"answer":457,"analysis":17},881590,[487,488,489,490],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":26},{"key":25,"text":17,"correct":21},{"key":28,"text":17,"correct":26},{"id":492,"libraryId":5,"type":432,"typeLabel":433,"stem":493,"options":494,"answer":503,"analysis":17},881591,"关于循环水泵的耗电输热比，正确的是( )。",[495,497,499,501],{"key":20,"text":496,"correct":21},"数值大节能",{"key":23,"text":498,"correct":26},"与循环水泵设计工作点效率成反比",{"key":25,"text":500,"correct":26},"其允许值与循环水泵流量成正比",{"key":28,"text":502,"correct":26},"室外供回水管主干线总长度与允许比摩阻成反比","BCD",{"id":505,"libraryId":5,"type":432,"typeLabel":433,"stem":506,"options":507,"answer":503,"analysis":17},881592,"关于空气源热泵用压缩机，下列哪几种说法是正确的？( )",[508,510,512,514],{"key":20,"text":509,"correct":21},"与一般的制冷压缩机相同",{"key":23,"text":511,"correct":26},"宜采用封闭式压缩机",{"key":25,"text":513,"correct":26},"需装设润滑油电加热器",{"key":28,"text":515,"correct":26},"应有较小的相对余隙容积",{"id":517,"libraryId":5,"type":432,"typeLabel":433,"stem":518,"options":519,"answer":444,"analysis":17},881593,"空气加湿设备中，属于等焓加湿原理的加湿设备有下列哪几项？",[520,522,524,526],{"key":20,"text":521,"correct":26},"喷循环水的喷淋室",{"key":23,"text":523,"correct":26},"高压喷雾加湿器",{"key":25,"text":525,"correct":26},"湿膜加湿器",{"key":28,"text":527,"correct":26},"超声波加湿器",{"id":529,"libraryId":5,"type":432,"typeLabel":433,"stem":530,"options":531,"answer":540,"analysis":17},881594,"高效过滤器的滤速选取要求是( )。",[532,534,536,538],{"key":20,"text":533,"correct":21},"高效和超高效过滤器的滤速取3～4cm\u002Fs",{"key":23,"text":535,"correct":26},"高效和超高效过滤器的滤速取2～3cm／s",{"key":25,"text":537,"correct":26},"亚高效过滤器的滤速取5～7cm／s",{"key":28,"text":539,"correct":21},"亚高效过滤器的滤速取4～5cm／s","BC",{"id":542,"libraryId":5,"type":432,"typeLabel":433,"stem":543,"options":544,"answer":553,"analysis":17},881595,"室外设备噪声控制的原则有( )。",[545,547,549,551],{"key":20,"text":546,"correct":26},"尽量选用低噪声设备",{"key":23,"text":548,"correct":26},"确定合理的设备位置",{"key":25,"text":550,"correct":26},"采用隔声屏蔽以减少设备对需要安静的房间的影响",{"key":28,"text":552,"correct":21},"室外冷却塔和水泵的噪声不需要考虑","ABC",{"id":555,"libraryId":5,"type":432,"typeLabel":433,"stem":556,"options":557,"answer":553,"analysis":17},881596,"蒸汽供暖系统管道中疏水器的作用是( )。",[558,560,562,564],{"key":20,"text":559,"correct":26},"阻止蒸汽",{"key":23,"text":561,"correct":26},"排除冷凝水",{"key":25,"text":563,"correct":26},"排除空气",{"key":28,"text":565,"correct":21},"定压",{"id":567,"libraryId":5,"type":432,"typeLabel":433,"stem":568,"options":569,"answer":553,"analysis":17},881597,"与室内单位容积发尘量相关的参数有( )。",[570,572,574,576],{"key":20,"text":571,"correct":26},"假想人员密度",{"key":23,"text":573,"correct":26},"人数",{"key":25,"text":575,"correct":26},"室内面积",{"key":28,"text":577,"correct":21},"室类型",{"id":579,"libraryId":5,"type":432,"typeLabel":433,"stem":580,"options":581,"answer":503,"analysis":17},881598,"洁净室送、回风量韵确定，下列表述中哪几项是错误的？( )",[582,584,586,588],{"key":20,"text":583,"correct":21},"回风量为送风量减去排风量和渗出量之和",{"key":23,"text":585,"correct":26},"送风量为根据热湿负荷确定的送风量",{"key":25,"text":587,"correct":26},"送风量为保证洁净度等级的送风量",{"key":28,"text":589,"correct":26},"送风量取B和C中的大值",{"id":591,"libraryId":5,"type":432,"typeLabel":433,"stem":592,"options":593,"answer":444,"analysis":17},881599,"对于以合成纤维非织造滤料制成的脉冲吹清灰的滤筒式除尘器，其性能或过滤机理的表述，下列哪几项是错误的？( )",[594,595,597,599],{"key":20,"text":17,"correct":26},{"key":23,"text":596,"correct":26},"过滤风速＞1.2m\u002Fmin",{"key":25,"text":598,"correct":26},"属于表面过滤类型",{"key":28,"text":600,"correct":26},"设备阻力≤1300Pa",{"id":602,"libraryId":5,"type":432,"typeLabel":433,"stem":603,"options":604,"answer":470,"analysis":17},881600,"供暖系统的阀门强度和严密性试验，正确的做法应是下列哪几项？( )",[605,607,609,611],{"key":20,"text":606,"correct":21},"安装在主干管上的阀门，应逐个进行试验",{"key":23,"text":608,"correct":21},"阀门的强度试验压力为公称压力的1.2倍",{"key":25,"text":610,"correct":26},"阀门的严密性试验压力为公称压力的1.1倍",{"key":28,"text":612,"correct":26},"最短试验持续时间，随阀门公称直径的增大而延长",[614,617,620,623,626,629],{"id":15,"name":615,"category":7,"favorite":616},"领导干部任职前廉政法规知识测试题",92,{"id":618,"name":619,"category":7,"favorite":15},595,"建筑结构与设备",{"id":621,"name":622,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":624,"name":625,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":627,"name":628,"category":7,"favorite":8},534,"BIM工程师",{"id":630,"name":628,"category":7,"favorite":8},535]