[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-34":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":607},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,34,50,2054,[13,34,46,58,70,82,94,106,118,130,137,149,161,173,185,197,209,221,233,245,257,269,281,293,305,317,329,341,349,361,373,385,397,409,421,433,445,457,469,476,487,499,511,523,535,547,559,571,583,595],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},881501,1,"单选题","在其他条件不变的情况下，空调变频控制方法中，正确的是( )。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","空调制冷设备启停控制的节能率低于变频控制",false,{"key":24,"text":25,"correct":22},"B","变频控制可以提高风机额定工况运行效率",{"key":27,"text":28,"correct":22},"C","水泵的功率与电动机频率成正比",{"key":30,"text":31,"correct":32},"D","风机功率与转速的三次幂成正比",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},881502,"设有火灾自动报警系统和自动喷水灭火系统的高层建筑的地下室，每个防火分区最大允许建筑面积为( )。",[38,40,42,44],{"key":20,"text":39,"correct":22},"500㎡",{"key":24,"text":41,"correct":32},"1000㎡",{"key":27,"text":43,"correct":22},"1500㎡",{"key":30,"text":45,"correct":22},"2000㎡",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":30,"analysis":33},881503,"调频泵组供水系统水泵的耗电量( )。",[50,52,54,56],{"key":20,"text":51,"correct":22},"与流量变化的一次方成正比",{"key":24,"text":53,"correct":22},"与流量变化韵二次方成正比",{"key":27,"text":55,"correct":22},"与流量变化的三次方成正比",{"key":30,"text":57,"correct":32},"与系统的工作压力有关，会因流量变化而略有变化",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},881504,"有一工厂厂区采用蒸汽供暖系统，下列选项正确的是( )。",[62,64,66,68],{"key":20,"text":63,"correct":22},"设计低压蒸汽供暖系统，采用双管下供下回系统，可避免汽水撞击声",{"key":24,"text":65,"correct":32},"设计低压蒸汽机械回水供暖系统时，锅炉高于底层散热器，则凝水箱需要安装在低于底层散热器和凝水管的位置",{"key":27,"text":67,"correct":22},"设计高压蒸汽开式余压回水系统时，锅炉房的闭式凝水箱顶标高应低于室外凝水干管最低点标高",{"key":30,"text":69,"correct":22},"设计高压蒸汽闭式余压回水系统时，锅炉房的闭式凝水箱顶标高应低于室外凝水干管最低点标高",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},881505,"关于热量表的设计和安装，下列哪个做法是错误的？( )",[74,76,78,80],{"key":20,"text":75,"correct":22},"热量表按设计流量的80%选型",{"key":24,"text":77,"correct":22},"热量表的流量传感器安装在回水管上",{"key":27,"text":79,"correct":32},"热量表按管道直径直接选用",{"key":30,"text":81,"correct":22},"热量表具有数据远传扩展功能",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":30,"analysis":33},881506,"冷库围护结构热流量计算的室外计算温度，应采用( )。",[86,88,90,92],{"key":20,"text":87,"correct":22},"夏季空调室外计算干球温度",{"key":24,"text":89,"correct":22},"夏季通风室外计算干球温度",{"key":27,"text":91,"correct":22},"最热月平均温度",{"key":30,"text":93,"correct":32},"夏季空调日平均温度",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},881507,"下列哪个因素与确定低温热水地面辐射供暖塑料加热管壁厚无关？( )",[98,100,102,104],{"key":20,"text":99,"correct":32},"地面荷载",{"key":24,"text":101,"correct":22},"工作压力",{"key":27,"text":103,"correct":22},"工作温度",{"key":30,"text":105,"correct":22},"管道材质",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},881508,"水源热泵机组采用地下水为水源时，下列哪一项表述是错误的？( )",[110,112,114,116],{"key":20,"text":111,"correct":32},"采用地下水地源热泵机组必然经济合理",{"key":24,"text":113,"correct":22},"应考虑水资源条件",{"key":27,"text":115,"correct":22},"地下水应采取可靠的回灌措施，回灌水不得对地下水资源造成污染",{"key":30,"text":117,"correct":22},"采用小型单元式机组，应设板式换热器间接换热",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":30,"analysis":33},881509,"层高大于4m的工业建筑，计算围护结构耗热量时，冬季室内设计温度的确定，下列哪一项是错误的？( )",[122,124,126,128],{"key":20,"text":123,"correct":22},"地面应采用工作地点的温度",{"key":24,"text":125,"correct":22},"屋顶下的温度可根据温度梯度、房间高度和工作地点温度进行计算",{"key":27,"text":127,"correct":22},"墙面应采用工作地点温度和屋顶下温度的平均值",{"key":30,"text":129,"correct":32},"门窗采用工作地点的温度",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":132,"answer":20,"analysis":33},881510,[133,134,135,136],{"key":20,"text":33,"correct":32},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":30,"text":33,"correct":22},{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":30,"analysis":33},881511,"下列选择风管内参数测定断面的原则中( )是错误的。",[141,143,145,147],{"key":20,"text":142,"correct":22},"尽可能选择在气流平稳的直管段上",{"key":24,"text":144,"correct":22},"在局部构件下游间距4～5倍管径外",{"key":27,"text":146,"correct":22},"在局部构件上游间距2倍管径外",{"key":30,"text":148,"correct":32},"若现场无法满足上述条件时，增加测定断面上的测点数即可",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":30,"analysis":33},881512,"关闭阀门的动作温度的表述，下列哪一项是错误的？( )",[153,155,157,159],{"key":20,"text":154,"correct":22},"厨房排油烟管上的防火阀的关阀动作温度为150℃",{"key":24,"text":156,"correct":22},"卫生间排风支管上的防火阀的关阀动作温度为70℃",{"key":27,"text":158,"correct":22},"消防排烟系统中的排烟防火阀的关阀动作温度为280℃",{"key":30,"text":160,"correct":32},"正压送风系统中的加压送风阀的关阀动作温度为70℃",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":24,"analysis":33},881513,"选择开式热水热力管网补水装置时，下列做法正确的是( )。",[165,167,169,171],{"key":20,"text":166,"correct":22},"补水泵的流量取系统循环水量的2%",{"key":24,"text":168,"correct":32},"补水泵的流量不小于生活热水最大设计流量和供热系统泄漏量之和",{"key":27,"text":170,"correct":22},"补水装置的流量取系统循环水量的5%",{"key":30,"text":172,"correct":22},"设置1台补水泵",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":20,"analysis":33},881514,"蒸气压缩制冷循环中，在节流阀前设置再冷器的目的是( )。",[177,179,181,183],{"key":20,"text":178,"correct":32},"提高制冷系数",{"key":24,"text":180,"correct":22},"增加蒸气量",{"key":27,"text":182,"correct":22},"提高压力",{"key":30,"text":184,"correct":22},"提高温度",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":24,"analysis":33},881515,"下列哪项是送风用静电空气过滤器与工业除尘静电除尘器的主要区别？( )",[189,191,193,195],{"key":20,"text":190,"correct":22},"从空气中分离颗粒物的工作机理不同",{"key":24,"text":192,"correct":32},"电晕极的静电极性不同",{"key":27,"text":194,"correct":22},"处理空气流量不同",{"key":30,"text":196,"correct":22},"净化效率不同",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":24,"analysis":33},881516,"正常运行的热水供暖系统，若有1个用户突然发生故障停止供暖，下列哪个说法是正确的？( )",[201,203,205,207],{"key":20,"text":202,"correct":22},"其他用户的流量均减小",{"key":24,"text":204,"correct":32},"其他用户的流量均增加",{"key":27,"text":206,"correct":22},"其他用户流量不变",{"key":30,"text":208,"correct":22},"有的用户流量增加，有的用户流量减小",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":30,"analysis":33},881517,"冷热电三联供系统的辅助热源设备不包括下列哪项？( )",[213,215,217,219],{"key":20,"text":214,"correct":22},"燃气锅炉",{"key":24,"text":216,"correct":22},"燃气直燃机",{"key":27,"text":218,"correct":22},"热泵",{"key":30,"text":220,"correct":32},"烟气余热回收装置",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":30,"analysis":33},881518,"下列哪一项不是热力管网管道热胀冷缩受约束产生的作用力？( )",[225,227,229,231],{"key":20,"text":226,"correct":22},"活动支架摩擦力在管道中产生的轴向力",{"key":24,"text":228,"correct":22},"直埋敷设锚固段的轴向力",{"key":27,"text":230,"correct":22},"直埋敷设过渡段土壤摩擦力在管道中产生的轴向力",{"key":30,"text":232,"correct":32},"弯管补偿器的弹性力",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":27,"analysis":33},881519,"绿色公共建筑物周围人行区风速应低于( )。",[237,239,241,243],{"key":20,"text":238,"correct":22},"3m\u002Fs",{"key":24,"text":240,"correct":22},"4m\u002Fs",{"key":27,"text":242,"correct":32},"5m\u002Fs",{"key":30,"text":244,"correct":22},"6m\u002Fs",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":30,"analysis":33},881520,"( )需采取防止冷库地面冻胀的措施。",[249,251,253,255],{"key":20,"text":250,"correct":22},"冷库所有冷间",{"key":24,"text":252,"correct":22},"冷库底层冷间",{"key":27,"text":254,"correct":22},"低温冷库",{"key":30,"text":256,"correct":32},"冷库底层设计温度低于0℃的冷间",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":30,"analysis":33},881521,"利用穿堂风进行自然通风的厂房，其迎风面与夏季最多风向宜为( )，且不应小于( )。",[261,263,265,267],{"key":20,"text":262,"correct":22},"40°～60°，40°",{"key":24,"text":264,"correct":22},"45°～60°，45°",{"key":27,"text":266,"correct":22},"45°～90°，40°",{"key":30,"text":268,"correct":32},"60°～90°，45°",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":27,"analysis":33},881522,"下列有关供暖、通风与空调节能技术措施中，哪项是错误的？",[273,275,277,279],{"key":20,"text":274,"correct":22},"高大空间冬季供暖时，采用“地板辐射十底部区域送风”相结合的方式",{"key":24,"text":276,"correct":22},"冷、热源设备应采用同种规格中的高能效比设备",{"key":27,"text":278,"correct":32},"应使开式冷却塔冷却后的出水温度低于空气的湿球温度",{"key":30,"text":280,"correct":22},"应使风系统具有合理的半径",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":24,"analysis":33},881523,"冷却物冷藏间由于贮存的大都是生鲜食品，故要求保持大面积的恒温恒湿，库内各区域的温度差应小于( )℃，湿度差小于( )，以免食品冻坏或干萎霉烂。",[285,287,289,291],{"key":20,"text":286,"correct":22},"0.5，5%",{"key":24,"text":288,"correct":32},"0.5，4%",{"key":27,"text":290,"correct":22},"0.6，5%",{"key":30,"text":292,"correct":22},"0.6，4%",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":24,"analysis":33},881524,"对于蒸气压缩制冷循环，以下说法错误的是( )。",[297,299,301,303],{"key":20,"text":298,"correct":22},"在相同的蒸发温度和冷凝温度下，理论循环的制冷量小于理想循环的",{"key":24,"text":300,"correct":32},"节流损失与制冷剂物性无关",{"key":27,"text":302,"correct":22},"理想循环会使制冷机遭受损坏",{"key":30,"text":304,"correct":22},"理论循环存在节流损失",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":30,"analysis":33},881525,"选择排烟兼排风系统风机时风量选择参数( )。",[309,311,313,315],{"key":20,"text":310,"correct":22},"应附加5%～10%",{"key":24,"text":312,"correct":22},"宜附加10%～15%",{"key":27,"text":314,"correct":22},"宜附加15%～20%",{"key":30,"text":316,"correct":32},"宜附加10%～20%",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":24,"analysis":33},881526,"制冷量大于( )的蒸气压缩制冷循环冷水(热泵)机组应配置容量卸载机构，其动作需灵活可靠。",[321,323,325,327],{"key":20,"text":322,"correct":22},"50kW",{"key":24,"text":324,"correct":32},"70kW",{"key":27,"text":326,"correct":22},"100kW",{"key":30,"text":328,"correct":22},"120kW",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":24,"analysis":33},881527,"某购物中心采用热水吊顶辐射板供暖，辐射板的安装高度为6m，购物中心顶棚面积为200㎡，辐射板面积为60㎡，则辐射板的最高平均水温应为( )。",[333,335,337,339],{"key":20,"text":334,"correct":22},"87℃",{"key":24,"text":336,"correct":32},"75℃",{"key":27,"text":338,"correct":22},"69℃",{"key":30,"text":340,"correct":22},"不确定",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":27,"analysis":33},881528,"汽车库内的CO浓度超过( )时应设置机械通风系统。",[345,346,347,348],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":32},{"key":30,"text":33,"correct":22},{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":27,"analysis":33},881529,"公共建筑热工设计有关要求中，下列哪一项是错误的？( )",[353,355,357,359],{"key":20,"text":354,"correct":22},"建筑窗(不包括透明幕墙)墙面积比小于0.4时，玻璃或其他透明材料的可见光透射比不应小于0.4",{"key":24,"text":356,"correct":22},"屋顶透明部分的面积不应大于屋顶总面面积的20%",{"key":27,"text":358,"correct":32},"夏热冬冷地区屋面传热系数K≤0.9W\u002F(㎡·K)",{"key":30,"text":360,"correct":22},"寒冷地区建筑体形系数不应大于0.4，不能满足要求时，必须进行围护结构热工性能的权衡判断",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":27,"analysis":33},881530,"风道中安装的消声器，当要求消声频谱范围覆盖低、中、高频带时，正确选择的消声器应是下列哪一项？",[365,367,369,371],{"key":20,"text":366,"correct":22},"阻性消声器",{"key":24,"text":368,"correct":22},"抗性消声器",{"key":27,"text":370,"correct":32},"阻抗复合消声器",{"key":30,"text":372,"correct":22},"共振型消声器",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":24,"analysis":33},881531,"冷间冷却设备每一通路的压力降，应控制在饱和制冷剂饱和温度降低( )。",[377,379,381,383],{"key":20,"text":378,"correct":22},"0.5℃",{"key":24,"text":380,"correct":32},"1.0℃",{"key":27,"text":382,"correct":22},"1.5℃",{"key":30,"text":384,"correct":22},"2.0℃",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":30,"analysis":33},881532,"关于事故排风系统的排风口与机械送风系统的进风口的水平距离.下列哪个是允许的？( )",[389,391,393,395],{"key":20,"text":390,"correct":22},"18m",{"key":24,"text":392,"correct":22},"15m",{"key":27,"text":394,"correct":22},"10m",{"key":30,"text":396,"correct":32},"小于20m时，排风口高于进风口不小于6m",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":30,"analysis":33},881533,"关于空气源热泵的表述，错误的是下列哪一项？",[401,403,405,407],{"key":20,"text":402,"correct":22},"空气源热泵不存在热量堆积问题，不用考虑冬季与夏季的热量平衡",{"key":24,"text":404,"correct":22},"大量采用风冷热泵机组会导致夏季城市热岛效应加剧",{"key":27,"text":406,"correct":22},"低温空气源热泵采用双级压缩循环时，可在整个冬季保持较高的能效水平",{"key":30,"text":408,"correct":32},"空气源热泵可以作为水环热泵冬季补热的一种方式",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":24,"analysis":33},881534,"采用( )可完成等温加湿。",[413,415,417,419],{"key":20,"text":414,"correct":22},"离心加湿器和超声波加湿器",{"key":24,"text":416,"correct":32},"干蒸汽加湿器和电加湿器",{"key":27,"text":418,"correct":22},"电加湿器和表面蒸发式加湿器",{"key":30,"text":420,"correct":22},"喷水室和超声波加湿器",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":27,"analysis":33},881535,"《洁净规范》中的100级，也就是传统的100级，相当于新《洁净规范》中的洁净度等级(N)( )级。",[425,427,429,431],{"key":20,"text":426,"correct":22},"3",{"key":24,"text":428,"correct":22},"4",{"key":27,"text":430,"correct":32},"5",{"key":30,"text":432,"correct":22},"6",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":27,"analysis":33},881536,"公共建筑空调冷、热水系统采用二级泵系统的条件，应为各环路压力损失相差悬殊。当采用二级泵系统时，对各个环路压力损失相差数值的具体判据是下列哪一项？( )",[437,439,441,443],{"key":20,"text":438,"correct":22},"各环路压力损失相差数值大于90kPa",{"key":24,"text":440,"correct":22},"各环路压力损失相差数值大于70kPa",{"key":27,"text":442,"correct":32},"各环路压力损失相差数值大于50kPa",{"key":30,"text":444,"correct":22},"各环路压力损失相差数值大于30kPa",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":27,"analysis":33},881537,"适合静电除尘器的使用环境是下列哪一项？( )",[449,451,453,455],{"key":20,"text":450,"correct":22},"有爆炸性气体产生的环境",{"key":24,"text":452,"correct":22},"在常温条件下产生易燃的油雾",{"key":27,"text":454,"correct":32},"高温(400℃)含尘气体",{"key":30,"text":456,"correct":22},"相对湿度大于80%的含尘气体除尘",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":24,"analysis":33},881538,"旋风除尘器“分割粒径”的正确含义是哪一项？",[461,463,465,467],{"key":20,"text":462,"correct":22},"在粒径分布中，累计质量占总质量的50%时对应的粒径",{"key":24,"text":464,"correct":32},"分级效率为50%时所对应的粒径",{"key":27,"text":466,"correct":22},"在粒径分布中，累计粒子数占总粒子数的50%时对应的粒径",{"key":30,"text":468,"correct":22},"正好将全部粒子质量分成相等两部分时对应的粒径",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":471,"answer":27,"analysis":33},881539,[472,473,474,475],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":32},{"key":30,"text":33,"correct":22},{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":478,"answer":24,"analysis":33},881540,[479,481,483,485],{"key":20,"text":480,"correct":22},"99.83%",{"key":24,"text":482,"correct":32},"99.91%",{"key":27,"text":484,"correct":22},"99.89%",{"key":30,"text":486,"correct":22},"99.87%",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":27,"analysis":33},881541,"多层车间，在工艺条件允许下热源尽量设在( )，进风设在( )。",[491,493,495,497],{"key":20,"text":492,"correct":22},"下层，上层",{"key":24,"text":494,"correct":22},"上层或下层，下层",{"key":27,"text":496,"correct":32},"上层，下层",{"key":30,"text":498,"correct":22},"下层，上层或下层",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":24,"analysis":33},881542,"根据《民用暖规》的规定，舒适性空调Ⅰ级热舒适度对应的夏季室内计算温度为24～26℃，计算相对湿度为40%～60%，下列说法中正确的是( )。",[503,505,507,509],{"key":20,"text":504,"correct":22},"分体空调方式难以满足上述相对湿度要求，因此舒适性空调不宜采用分体空调方式",{"key":24,"text":506,"correct":32},"在夏季工况下，分体空调方式通常可以达到比风机盘管集中空调方式更低的室内相对湿度",{"key":27,"text":508,"correct":22},"为了提高舒适度，空调夏季室内计算温度应选择22℃",{"key":30,"text":510,"correct":22},"为了达到上述相对湿度的要求，舒适性空调系统宜设置除湿装置",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":27,"analysis":33},881543,"下列关于变风量空调系统的表述中正确的是( )。",[515,517,519,521],{"key":20,"text":516,"correct":22},"风量越小能耗也越少，因此不应对变风量末端的最小风量进行限制",{"key":24,"text":518,"correct":22},"变风量空调系统调温时，由于风量减少，所以室内噪声通常较小",{"key":27,"text":520,"correct":32},"变风量空调系统每个房间的新风量不能单独调节控制",{"key":30,"text":522,"correct":22},"由于每个房间的送风量可以独立控制，内外区没有必要分开设置",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":20,"analysis":33},881544,"关于地源热泵系统，下列说法错误的是( )。",[527,529,531,533],{"key":20,"text":528,"correct":32},"采用地埋管系统应用面积为2000㎡时，必须作岩土热响应试验",{"key":24,"text":530,"correct":22},"采用地埋管系统应进行全年空调动态负荷计算",{"key":27,"text":532,"correct":22},"当地埋管最大释热量和最大吸热量相差不大时，换热器取供冷和供热计算长度的较大值",{"key":30,"text":534,"correct":22},"当地埋管最大释热量和最大吸热量相差较大时，换热器取供冷和供热计算长度较小值，并增加辅助冷热源",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":27,"analysis":33},881545,"制冷装置冷凝器的排热量近似于下列哪一项？( )",[539,541,543,545],{"key":20,"text":540,"correct":22},"制冷量",{"key":24,"text":542,"correct":22},"制冷量+压缩机轴功率",{"key":27,"text":544,"correct":32},"制冷量+压缩机指示功率",{"key":30,"text":546,"correct":22},"制冷量+压缩机摩擦功率",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":30,"analysis":33},881546,"某办公楼采用风机盘管+新风的空调设计方案，风机盘管均设置温控阀，采用DeST全年逐时模拟软件进行空调负荷计算，得到全楼全年876.0h的综合逐时负荷，空调系统的设计冷负荷应选其中的( )。",[551,553,555,557],{"key":20,"text":552,"correct":22},"冷负荷最大值",{"key":24,"text":554,"correct":22},"冷负荷平均值",{"key":27,"text":556,"correct":22},"将冷负荷按从大到小排列，取第50个值",{"key":30,"text":558,"correct":32},"将冷负荷按从大到小排列，取第51个值",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":30,"analysis":33},881547,"一空调房间气流组织采用侧送风，风口当量直径为0.2m，单股送风射流所管辖的房间面积为4㎡，则送风口的允许最大出口风速为( )。",[563,565,567,569],{"key":20,"text":564,"correct":22},"1.9m／s",{"key":24,"text":566,"correct":22},"2.5m／s",{"key":27,"text":568,"correct":22},"4.8m\u002Fs",{"key":30,"text":570,"correct":32},"3.6m\u002Fs",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":27,"analysis":33},881548,"某洁净室要求为相对负压，下列哪一种控制方法是正确的？",[575,577,579,581],{"key":20,"text":576,"correct":22},"送风量大于回风量",{"key":24,"text":578,"correct":22},"送风量等于回风量",{"key":27,"text":580,"correct":32},"送风量小于回风量",{"key":30,"text":582,"correct":22},"安装余压阀",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":20,"analysis":33},881549,"洁净室的正压或负压应根据洁净室防扩散、防污染功能确定，不同级别的洁净室以及洁净区与非洁净区的压差、洁净区与室外的压差分别不小于( )。",[587,589,591,593],{"key":20,"text":588,"correct":32},"5Pa和10Pa",{"key":24,"text":590,"correct":22},"10Pa和15Pa",{"key":27,"text":592,"correct":22},"15Pa和20Pa",{"key":30,"text":594,"correct":22},"25Pa和30Pa",{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":30,"analysis":33},881550,"采用蒸汽和95℃以上的高温水为热媒时，民用建筑容积式水加热器的贮热量应( )。",[599,601,603,605],{"key":20,"text":600,"correct":22},"不小于20min的设计小时耗热量",{"key":24,"text":602,"correct":22},"不小于30min的设计小时耗热量",{"key":27,"text":604,"correct":22},"不小于40min的设计小时耗热量",{"key":30,"text":606,"correct":32},"不小于45min的设计小时耗热量",[608,611,614,617,620,623],{"id":15,"name":609,"category":7,"favorite":610},"领导干部任职前廉政法规知识测试题",92,{"id":612,"name":613,"category":7,"favorite":15},595,"建筑结构与设备",{"id":615,"name":616,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":618,"name":619,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":621,"name":622,"category":7,"favorite":8},534,"BIM工程师",{"id":624,"name":622,"category":7,"favorite":8},535]