[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-33":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":629},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,33,50,2054,[13,34,48,60,73,86,99,111,123,135,147,159,172,185,197,209,221,233,245,258,271,283,295,307,318,331,343,355,367,379,391,403,415,425,437,449,461,473,485,497,509,520,532,545,557,569,581,593,605,617],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":17},881451,2,"多选题","",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","过程2-2′的热量为面积22′782，且为放热过程",true,{"key":24,"text":25,"correct":22},"B","过程2′-3的热量为面积2′3572′，且为放热过程",{"key":27,"text":28,"correct":29},"C","过程3-4的热量为面积34653，且为吸热过程",false,{"key":31,"text":32,"correct":22},"D","过程41的热量为面积41864，且为吸热过程","ABD",{"id":35,"libraryId":5,"type":36,"typeLabel":37,"stem":38,"options":39,"answer":20,"analysis":17},881452,1,"单选题","关于采用蒸发冷却空调系统的原则，下列哪一项是错误的？",[40,42,44,46],{"key":20,"text":41,"correct":22},"在满足使用要求的前提下，夏季空气调节室外计算湿球温度较低的地区宜采用蒸发冷却空调系统",{"key":24,"text":43,"correct":29},"在新疆宜采用蒸发冷却空调系统",{"key":27,"text":45,"correct":29},"西北地区宜采用蒸发冷却空调系统，理论计算送风温度绝大多数在16～20℃之间",{"key":31,"text":47,"correct":29},"贵州地区宜采用三级蒸发冷却空调系统",{"id":49,"libraryId":5,"type":36,"typeLabel":37,"stem":50,"options":51,"answer":24,"analysis":17},881453,"实现均匀送风基本条件，错误的是( )。",[52,54,56,58],{"key":20,"text":53,"correct":29},"保持各侧孔静压相等",{"key":24,"text":55,"correct":22},"保持各侧孔动压相等",{"key":27,"text":57,"correct":29},"保持各侧孔流量系数相等",{"key":31,"text":59,"correct":29},"增大出流角",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":72,"analysis":17},881454,"排水管道的连接，应( )。",[64,66,68,70],{"key":20,"text":65,"correct":22},"卫生器具排水管与排水横管垂直连接，应采用90°斜三通",{"key":24,"text":67,"correct":22},"排水管道的横管与立管连接，宜采用45°斜三通、45°斜四通，以及顺水三通和顺水四通",{"key":27,"text":69,"correct":22},"排水立管与排出管端部的连接，宜采用两个45°弯头或弯曲半径不小于4倍管径的90°弯头",{"key":31,"text":71,"correct":22},"排水管应避免轴线偏置，当受条件限制时，宜采用乙字弯或两个45°弯头连接","ABCD",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":85,"analysis":17},881455,"工程设计中，能防止或减轻系统水平失调的方法有( )。",[77,79,81,83],{"key":20,"text":78,"correct":22},"供、回水干管采用同程式",{"key":24,"text":80,"correct":29},"采用等温降法进行水力计算",{"key":27,"text":82,"correct":22},"采用不等温降法进行水力计算",{"key":31,"text":84,"correct":22},"仍采用同程式，但首先计算最近立管环路","ACD",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":98,"analysis":17},881456,"冷却塔的冷却水出水温度高于设计值时，会影响冷水机组的效率，下列原因分析与改善措施正确的是( )。",[90,92,94,96],{"key":20,"text":91,"correct":29},"冷却水量不足，应加大冷却水泵的流量",{"key":24,"text":93,"correct":22},"冷却塔通风不好，应改善通风环境，避免热气旁通",{"key":27,"text":95,"correct":22},"冷却塔风机风量不够，应加大风量",{"key":31,"text":97,"correct":22},"冷却塔出水管在室外暴露部分过长，应加强保温","BCD",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":33,"analysis":17},881457,"滚动转子式压缩机的特点是( )。",[103,105,107,109],{"key":20,"text":104,"correct":22},"容积效率高、振动小、噪声低",{"key":24,"text":106,"correct":22},"机构简单，紧凑",{"key":27,"text":108,"correct":29},"零部件少、体积小、重量轻、辅助装置较简单",{"key":31,"text":110,"correct":22},"易损件少，维修方便，加工精度要求高",{"id":112,"libraryId":5,"type":36,"typeLabel":37,"stem":113,"options":114,"answer":27,"analysis":17},881458,"竖直地埋管换热器的敷设要求是( )。",[115,117,119,121],{"key":20,"text":116,"correct":29},"埋管深度宜大于30m，钻孔孔径不宜小于0.11m，间距宜为3～6m",{"key":24,"text":118,"correct":29},"埋管深度宜大于30m，钻孔孔径不宜小于0.11m，间距宜为5～8m",{"key":27,"text":120,"correct":22},"埋管深度宜大于20m，钻孔孔径不宜小于0.11m，间距宜为3～6m",{"key":31,"text":122,"correct":29},"埋管深度宜大于20m，钻孔孔径不宜小于0.15m，间距宜为4～7m",{"id":124,"libraryId":5,"type":36,"typeLabel":37,"stem":125,"options":126,"answer":31,"analysis":17},881459,"对机械排烟系统排风机的要求是( )。",[127,129,131,133],{"key":20,"text":128,"correct":29},"无特殊要求",{"key":24,"text":130,"correct":29},"应采用钢制风机",{"key":27,"text":132,"correct":29},"应采用离心风机",{"key":31,"text":134,"correct":22},"可采用离心风机或排烟轴流风机，应保证在280℃时连续工作30min",{"id":136,"libraryId":5,"type":36,"typeLabel":37,"stem":137,"options":138,"answer":20,"analysis":17},881460,"( )的制冷剂一般不能用于一次节流不完全中间冷却的双级压缩制冷循环。",[139,141,143,145],{"key":20,"text":140,"correct":22},"排气温度高",{"key":24,"text":142,"correct":29},"吸气不能过热",{"key":27,"text":144,"correct":29},"冷凝温度低",{"key":31,"text":146,"correct":29},"压缩比小",{"id":148,"libraryId":5,"type":36,"typeLabel":37,"stem":149,"options":150,"answer":31,"analysis":17},881461,"洁净室的上、下技术夹层和洁净生产层，当作为同一防火分区时，防火分区的建筑面积( )。",[151,153,155,157],{"key":20,"text":152,"correct":29},"上、下夹层均计入",{"key":24,"text":154,"correct":29},"只计入上夹层",{"key":27,"text":156,"correct":29},"只计入下夹层",{"key":31,"text":158,"correct":22},"上、下夹层可不计入",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":171,"analysis":17},881462,"在各类冷水和热泵机组的产品样本中，均给出水侧污垢系数供用户参考，下列哪几项说法是正确的？( )",[163,165,167,169],{"key":20,"text":164,"correct":29},"水侧污垢系数小于要求者，制冷量和性能系数应折减",{"key":24,"text":166,"correct":22},"水侧污垢系数大于要求者，制冷量和性能系数应折减",{"key":27,"text":168,"correct":29},"水侧污垢系数对机组性能系数影响不大，可不考虑",{"key":31,"text":170,"correct":22},"水侧污垢系数造成压缩机高低压差增大，降低了机组性能系数","BD",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":184,"analysis":17},881463,"下面部位亦设专设通气管的是( )。",[176,178,180,182],{"key":20,"text":177,"correct":22},"生活排水立管所承担的卫生器具排水设计流量，当超过仅设伸顶通气管的排水立管最大排水能力时",{"key":24,"text":179,"correct":22},"建筑标准要求较高的多层住宅的生活污水立管",{"key":27,"text":181,"correct":22},"公共建筑10层及10层以上高层建筑的生活污水立管",{"key":31,"text":183,"correct":29},"每个生活立管的顶部","ABC",{"id":186,"libraryId":5,"type":36,"typeLabel":37,"stem":187,"options":188,"answer":27,"analysis":17},881464,"计算冷空气耗热量需要采用的外门窗缝隙渗风系数，与以下哪个因素有关？( )",[189,191,193,195],{"key":20,"text":190,"correct":29},"外门窗的朝向",{"key":24,"text":192,"correct":29},"冬季室外最多风向的平均风速",{"key":27,"text":194,"correct":22},"外门窗空气渗透性能分级",{"key":31,"text":196,"correct":29},"外门窗在建筑中的位置高度",{"id":198,"libraryId":5,"type":36,"typeLabel":37,"stem":199,"options":200,"answer":24,"analysis":17},881465,"-台本身不带隔振装置的设备，转数为1200r\u002Fmin，在隔振方面应选用( )。",[201,203,205,207],{"key":20,"text":202,"correct":29},"橡胶隔振器",{"key":24,"text":204,"correct":22},"弹簧隔振器",{"key":27,"text":206,"correct":29},"橡胶隔振垫",{"key":31,"text":208,"correct":29},"不需隔振",{"id":210,"libraryId":5,"type":36,"typeLabel":37,"stem":211,"options":212,"answer":20,"analysis":17},881466,"为了解决冬季低温环境下多联机供热量显著下降的问题，有厂家开发了喷气增焓技术，该技术是将中温、中压的冷媒蒸气喷入压缩机腔体中部，即压缩机除常规的吸气口和排气口外，增加了一个中间吸气口。关于该过程的表述，正确的是哪一项？",[213,215,217,219],{"key":20,"text":214,"correct":22},"增加了单位质量冷媒从外部大气的吸热能力",{"key":24,"text":216,"correct":29},"单位质量冷媒从外部大气的吸热能力保持不变",{"key":27,"text":218,"correct":29},"降低了冷媒从冷凝器流出的温度",{"key":31,"text":220,"correct":29},"增了通过压缩机的冷媒循环量",{"id":222,"libraryId":5,"type":36,"typeLabel":37,"stem":223,"options":224,"answer":31,"analysis":17},881467,"CFC中，对大气层中的臭氧层起破坏作用的是( )。",[225,227,229,231],{"key":20,"text":226,"correct":29},"C原子",{"key":24,"text":228,"correct":29},"H原子",{"key":27,"text":230,"correct":29},"O原子",{"key":31,"text":232,"correct":22},"Cl原子",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":72,"analysis":17},881468,"下列哪些地方的建筑物，计算供暖设计热负荷时要考虑风力附加？( )",[237,239,241,243],{"key":20,"text":238,"correct":22},"河边",{"key":24,"text":240,"correct":22},"旷野",{"key":27,"text":242,"correct":22},"海岸",{"key":31,"text":244,"correct":22},"不避风的高地",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":257,"analysis":17},881469,"锅炉房内对燃煤锅炉的布置要求下列哪些是正确的？( )",[249,251,253,255],{"key":20,"text":250,"correct":22},"操作地点和通道的净高不应低于2m",{"key":24,"text":252,"correct":29},"容量为0.7～2.8MW锅炉的炉前净距不应小于2m",{"key":27,"text":254,"correct":22},"容量为4.2～14MW锅炉的炉前净距不应小于4m",{"key":31,"text":256,"correct":29},"容量为29～58MW锅炉的炉前净距不应小于6m","AC",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":270,"analysis":17},881470,"下列制冷剂中，( )属于非共沸混合物。",[262,264,266,268],{"key":20,"text":263,"correct":29},"R134a",{"key":24,"text":265,"correct":22},"R407B",{"key":27,"text":267,"correct":22},"R407C",{"key":31,"text":269,"correct":29},"R290","BC",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":270,"analysis":17},881471,"测定管道风速的方法分为( )。",[275,277,279,281],{"key":20,"text":276,"correct":29},"直接式",{"key":24,"text":278,"correct":22},"直读式",{"key":27,"text":280,"correct":22},"间接式",{"key":31,"text":282,"correct":29},"动压式",{"id":284,"libraryId":5,"type":36,"typeLabel":37,"stem":285,"options":286,"answer":24,"analysis":17},881472,"“同程式热水采暖系统比异程式热水采暖系统易于平衡”的说法，哪一项是正确的？",[287,289,291,293],{"key":20,"text":288,"correct":29},"只有干管阻力大时，方为正确",{"key":24,"text":290,"correct":22},"只有支路阻力比较小时，方为正确",{"key":27,"text":292,"correct":29},"因为同程式系统各并联环路段长度基本相等，因此说法正确",{"key":31,"text":294,"correct":29},"只有支路阻力比较大时，方为正确",{"id":296,"libraryId":5,"type":36,"typeLabel":37,"stem":297,"options":298,"answer":31,"analysis":17},881473,"当建筑物内的生活用水既有室外管网直接供水，又有自行加压供水时，其给水引入管的设计流量应取( )。",[299,301,303,305],{"key":20,"text":300,"correct":29},"建筑物生活小时用水量",{"key":24,"text":302,"correct":29},"建筑物生活用水设计秒流量",{"key":27,"text":304,"correct":29},"管网直接部分生活用水设计秒流量与自行加压部分生活用水最大小时水量之和",{"key":31,"text":306,"correct":22},"管网直接部分生活用水设计秒流量与自行加压部分供水贮水调节池的设计补水量之和",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":171,"analysis":17},881474,"关于空调房间新风控制的说法中，正确的是( )。",[311,313,314,316],{"key":20,"text":312,"correct":29},"人员密度较大空调房间均应设置新风量需求控制装置",{"key":24,"text":17,"correct":22},{"key":27,"text":315,"correct":29},"新风量控制装置通常是根据室内VOC浓度来控制室内新风量",{"key":31,"text":317,"correct":22},"变风量空调系统难以对具体房间的新风量进行调控",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":330,"analysis":17},881475,"根据下列夏季工况性能参数评断，哪些冷水机组是节能产品？( )",[322,324,326,328],{"key":20,"text":323,"correct":22},"额定制冷量为50kW，额定能效比为3的风冷式冷水机组",{"key":24,"text":325,"correct":22},"额定制冷量为500kW，额定能效比为4.7的水冷式冷水机组",{"key":27,"text":327,"correct":29},"实测制冷量为50kW，能效比为3.1的风冷式冷水机组",{"key":31,"text":329,"correct":29},"额定制冷量为1000kW，额定能效比为5.0的水冷式冷水机组","AB",{"id":332,"libraryId":5,"type":36,"typeLabel":37,"stem":333,"options":334,"answer":20,"analysis":17},881476,"液态制冷剂在过冷器中的过冷过程可以近似看成( )。",[335,337,339,341],{"key":20,"text":336,"correct":22},"等压过程",{"key":24,"text":338,"correct":29},"等容过程",{"key":27,"text":340,"correct":29},"等焓过程",{"key":31,"text":342,"correct":29},"等温过程",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":330,"analysis":17},881477,"围护结构的蒸汽渗透阻与下列哪些因素有关？( )",[347,349,351,353],{"key":20,"text":348,"correct":22},"围护结构各层材料的厚度",{"key":24,"text":350,"correct":22},"围护结构各层材料的蒸汽渗透系数",{"key":27,"text":352,"correct":29},"围护结构保温材料重量湿度允许增量",{"key":31,"text":354,"correct":29},"室内空气的水蒸气分压力",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":184,"analysis":17},881478,"蒸汽热力网的设计流量( )。",[359,361,363,365],{"key":20,"text":360,"correct":22},"应按各用户的最大蒸汽流量之和乘以同时系数确定",{"key":24,"text":362,"correct":22},"当供热介质为饱和蒸汽时，设计流量包括补偿管道热损失产生的凝结水的蒸汽量",{"key":27,"text":364,"correct":22},"凝结水管道的设计流量应按蒸汽管道的设计流量乘以用户的凝结水回收率确定",{"key":31,"text":366,"correct":29},"应按各用户的最大蒸汽流量之和确定",{"id":368,"libraryId":5,"type":36,"typeLabel":37,"stem":369,"options":370,"answer":24,"analysis":17},881479,"关于局部排风罩的选择和机理，下列哪一项是错误的？( )",[371,373,375,377],{"key":20,"text":372,"correct":29},"密闭罩的排风口应设在罩内压力较高的部位",{"key":24,"text":374,"correct":22},"外部吸气罩的控制点风速大小与控制点距外部吸气罩吸气口的距离成正比",{"key":27,"text":376,"correct":29},"当排风柜内的发热量大时，可以采用自然通风，排气时其最小排风量需要按中和界高度不低于排风柜的工作孔上缘来确定",{"key":31,"text":378,"correct":29},"当伞形罩的扩张角α为30°～60°时，其局部阻力系数最小",{"id":380,"libraryId":5,"type":36,"typeLabel":37,"stem":381,"options":382,"answer":20,"analysis":17},881480,"当集中送风热风供暖采用平行送风射流时，每股射流作用的宽度和长度应为( )。",[383,385,387,389],{"key":20,"text":384,"correct":22},"射流作用宽度≤3～4倍房间高度，射流作用长度≤9倍房间高度",{"key":24,"text":386,"correct":29},"射流作用宽度＞3～4倍房间高度，射流作用长度＞9倍房间高度",{"key":27,"text":388,"correct":29},"射流作用宽度≤3～4倍房间高度，射流作用长度＞9倍房间高度",{"key":31,"text":390,"correct":29},"射流作用宽度＞3～4倍房间高度，射流作用长度≤9倍房间高度",{"id":392,"libraryId":5,"type":36,"typeLabel":37,"stem":393,"options":394,"answer":31,"analysis":17},881481,"绿色办公、宾馆类建筑( )的主要功能空间室内采光系数应满足现行国家标准GB\u002FT50033-2001《建筑采光设计标准》的要求。",[395,397,399,401],{"key":20,"text":396,"correct":29},"40%以上",{"key":24,"text":398,"correct":29},"50%以上",{"key":27,"text":400,"correct":29},"60%以上",{"key":31,"text":402,"correct":22},"75%以上",{"id":404,"libraryId":5,"type":36,"typeLabel":37,"stem":405,"options":406,"answer":20,"analysis":17},881482,"为防止循环水泵发生气蚀现象，循环水泵吸入口压力不应低于( )。",[407,409,411,413],{"key":20,"text":408,"correct":22},"50kPa",{"key":24,"text":410,"correct":29},"10kPa",{"key":27,"text":412,"correct":29},"30kPa",{"key":31,"text":414,"correct":29},"循环水泵人口处水温下对应的饱和压力",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":417,"answer":72,"analysis":17},881483,[418,419,421,423],{"key":20,"text":17,"correct":22},{"key":24,"text":420,"correct":22},"出口余压约320Pa",{"key":27,"text":422,"correct":22},"系统的阻力约下降了36%",{"key":31,"text":424,"correct":22},"机组风机的轴功率约下降了48.8%",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":98,"analysis":17},881484,"下列对静电除尘器的描述中，正确的是( )。",[429,431,433,435],{"key":20,"text":430,"correct":29},"静电除尘器可以有效处理各类干粉尘",{"key":24,"text":432,"correct":22},"荷电粉尘在电场力作用下向集尘极运动",{"key":27,"text":434,"correct":22},"与袋式除尘器相比，空气流动阻力小，运行能耗低",{"key":31,"text":436,"correct":22},"为减少产生臭氧，送风用静电过滤器通常采用正电晕",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":72,"analysis":17},881485,"住宅建筑集中采暖系统节能，要求调节、计量装置的做法是下列哪几项？",[441,443,445,447],{"key":20,"text":442,"correct":22},"设置分户温度调节装置",{"key":24,"text":444,"correct":22},"设置分室温度调节装置",{"key":27,"text":446,"correct":22},"设置分户(单元)计量装置",{"key":31,"text":448,"correct":22},"预留分户(单元)计量装置的位置",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":270,"analysis":17},881486,"地下汽车库可以采用自然排烟的必要条件是( )。",[453,455,457,459],{"key":20,"text":454,"correct":29},"面积不超过3000㎡",{"key":24,"text":456,"correct":22},"可开启的外窗面积不小于地面面积的2%",{"key":27,"text":458,"correct":22},"汽车库内任意点距离可开启外窗的长度不超过30m",{"key":31,"text":460,"correct":29},"必须有与自然排烟口面积相同的进风口",{"id":462,"libraryId":5,"type":36,"typeLabel":37,"stem":463,"options":464,"answer":24,"analysis":17},881487,"大中型冷库制冷系统中不凝性气体的排放方式是( )。",[465,467,469,471],{"key":20,"text":466,"correct":29},"混合气体直接排入大气",{"key":24,"text":468,"correct":22},"混合气体应通过不凝性气体分离器排放",{"key":27,"text":470,"correct":29},"混合气体定期排放",{"key":31,"text":472,"correct":29},"混合气体排入溶液或水",{"id":474,"libraryId":5,"type":36,"typeLabel":37,"stem":475,"options":476,"answer":31,"analysis":17},881488,"下列场所应设置排烟设施的是何项?( )。",[477,479,481,483],{"key":20,"text":478,"correct":29},"丙类厂房中建筑面积大于200㎡的地上房间",{"key":24,"text":480,"correct":29},"氧气站",{"key":27,"text":482,"correct":29},"任一层建筑面积大于5000㎡的生产氟利昂厂房",{"key":31,"text":484,"correct":22},"建筑面积20000㎡的钢铁冶炼厂房",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":98,"analysis":17},881489,"在下列的( )情况下，应采用双级蒸气压缩式制冷循环。",[489,491,493,495],{"key":20,"text":490,"correct":29},"压缩机的容积效率＜0.2",{"key":24,"text":492,"correct":22},"活塞式压缩机蒸发温度＜-30℃",{"key":27,"text":494,"correct":22},"螺杆式压缩机排气温度＞105℃",{"key":31,"text":496,"correct":22},"螺杆式压缩机蒸发温度＜-40℃",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":270,"analysis":17},881490,"某小区内现有建筑均为多层，各采暖系统静水压力均≯0.3MPa，现拟建一栋高层建筑，其采暖系统最高点静水压力为0.6MPa，试问该系统与外网连接方式最好采用下列哪几项？",[501,503,505,507],{"key":20,"text":502,"correct":29},"设换热器与外网间接连接",{"key":24,"text":504,"correct":22},"建筑内分高、低区采暖系统，低区与外网连接，高区设换热器与外网连接",{"key":27,"text":506,"correct":22},"建筑内分高、低区采暖系统，低区与外网连接，高区采用双水箱分层式系统与外网连接",{"key":31,"text":508,"correct":29},"设混水泵与外网直接连接",{"id":510,"libraryId":5,"type":36,"typeLabel":37,"stem":511,"options":512,"answer":27,"analysis":17},881491,"蒸汽压力大于( )称为高压蒸汽。",[513,515,516,518],{"key":20,"text":514,"correct":29},"40kPa",{"key":24,"text":408,"correct":29},{"key":27,"text":517,"correct":22},"70kPa",{"key":31,"text":519,"correct":29},"100kPa",{"id":521,"libraryId":5,"type":36,"typeLabel":37,"stem":522,"options":523,"answer":27,"analysis":17},881492,"关于制冷循环与制冷剂的表述，正确的是下列哪一项？",[524,526,528,530],{"key":20,"text":525,"correct":29},"卡诺循环的能效水平与制冷剂种类有关",{"key":24,"text":527,"correct":29},"GWP=O和ODP=O的制冷剂均是理想的制冷剂",{"key":27,"text":529,"correct":22},"温湿度独立控制系统节能的最主要原因是制取高温冷水的能效比高于制取低温冷水",{"key":31,"text":531,"correct":29},"冷凝温度越低，制冷机制取冷水的能效比越高",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":544,"analysis":17},881493,"某建筑的空调冷却水系统，冷却水泵的铭牌参数符合设计要求，运行时发现冷水泵启动后，总是“跳闸”而停泵。下列哪几项可能是产生问题的原因？",[536,538,540,542],{"key":20,"text":537,"correct":29},"冷却水系统的冷却塔高度过高，冷却水泵无法将水送至冷却塔",{"key":24,"text":539,"correct":29},"冷却水系统的水流阻力过大，使得水泵的实际扬程超过设计工作点的扬程",{"key":27,"text":541,"correct":22},"冷却水泵的电机保护开关的整定电流小于水泵设计参数的要求",{"key":31,"text":543,"correct":22},"冷却水泵的实际运行流量超过设计工作点的流量","CD",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":270,"analysis":17},881494,"设计选用普通离心式除尘器时，产品应符合国家的相关行业标准。问：在冷态条件下，压力损失存1000Pa以下测得除尘效率和漏风率，符合标准规定的是下列哪几项?( )。",[549,551,553,555],{"key":20,"text":550,"correct":29},"除尘效率为78.9%",{"key":24,"text":552,"correct":22},"除尘效率为81.5%",{"key":27,"text":554,"correct":22},"漏风率为1.2%",{"key":31,"text":556,"correct":29},"漏风率为2.1%",{"id":558,"libraryId":5,"type":36,"typeLabel":37,"stem":559,"options":560,"answer":24,"analysis":17},881495,"某四层办公楼中无隔热防火措施的排烟管道与可燃物之间的最小距离限值应为下列哪一项？",[561,563,565,567],{"key":20,"text":562,"correct":29},"100mm",{"key":24,"text":564,"correct":22},"150mm",{"key":27,"text":566,"correct":29},"180mm",{"key":31,"text":568,"correct":29},"200mm",{"id":570,"libraryId":5,"type":36,"typeLabel":37,"stem":571,"options":572,"answer":31,"analysis":17},881496,"新建热力站宜采用小型热力站的原因不包括下列哪一项？( )",[573,575,577,579],{"key":20,"text":574,"correct":29},"热力站供热面积越小，调控设备的节能效果越显著",{"key":24,"text":576,"correct":29},"水力平衡比较容易",{"key":27,"text":578,"correct":29},"采用大温差小流量的运行模式，有利于水泵节电",{"key":31,"text":580,"correct":22},"人工值守要求",{"id":582,"libraryId":5,"type":36,"typeLabel":37,"stem":583,"options":584,"answer":20,"analysis":17},881497,"欲从单质制冷剂的饱和状态热力性质表中查出其他参数，需要知道其中的( )。",[585,587,589,591],{"key":20,"text":586,"correct":22},"1个参数",{"key":24,"text":588,"correct":29},"2个参数",{"key":27,"text":590,"correct":29},"3个参数",{"key":31,"text":592,"correct":29},"4个参数",{"id":594,"libraryId":5,"type":36,"typeLabel":37,"stem":595,"options":596,"answer":24,"analysis":17},881498,"相对于满液式蒸发器而言，非满液蒸发器的( )。",[597,599,601,603],{"key":20,"text":598,"correct":29},"换热系数高",{"key":24,"text":600,"correct":22},"传热系数低",{"key":27,"text":602,"correct":29},"制冷剂充注量多",{"key":31,"text":604,"correct":29},"采用溶于润滑油的制冷剂时，润滑油不容易返回压缩机",{"id":606,"libraryId":5,"type":15,"typeLabel":16,"stem":607,"options":608,"answer":184,"analysis":17},881499,"对于广州某商场，希望设计三星级绿色建筑，下列哪些技术措施可能是错误的？( )",[609,611,613,615],{"key":20,"text":610,"correct":22},"为减少太阳辐射，取消采光中庭的设计",{"key":24,"text":612,"correct":22},"围护结构体系采用150mm的EPS外保温系统",{"key":27,"text":614,"correct":22},"照明功率密度按18W\u002F㎡设计",{"key":31,"text":616,"correct":29},"设计通风屋顶",{"id":618,"libraryId":5,"type":15,"typeLabel":16,"stem":619,"options":620,"answer":33,"analysis":17},881500,"下列对自动喷水灭火系统的水流指示器设置的说法，正确的是( )。",[621,623,625,627],{"key":20,"text":622,"correct":22},"每个防火分区应设",{"key":24,"text":624,"correct":22},"每个楼层均应设",{"key":27,"text":626,"correct":29},"设于每个防火分区最不利喷头处",{"key":31,"text":628,"correct":22},"水流指示器入口前设置控制阀时，应采用信号阀",[630,633,636,639,642,645],{"id":36,"name":631,"category":7,"favorite":632},"领导干部任职前廉政法规知识测试题",92,{"id":634,"name":635,"category":7,"favorite":36},595,"建筑结构与设备",{"id":637,"name":638,"category":7,"favorite":36},715,"招标采购专业知识与法律法规",{"id":640,"name":641,"category":7,"favorite":36},848,"市政方向-通用基础",{"id":643,"name":644,"category":7,"favorite":8},534,"BIM工程师",{"id":646,"name":644,"category":7,"favorite":8},535]