[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-32":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":621},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,32,50,2054,[13,34,47,60,72,85,98,111,123,131,144,156,168,181,193,205,217,229,241,253,265,277,289,302,314,326,338,350,362,374,386,398,410,422,434,446,458,470,482,494,505,517,525,537,549,561,573,585,597,609],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":17},881401,2,"多选题","",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","同等制冷量时，采用R123机组的理论输气量要比R134a制冷机的理论输气量大",true,{"key":24,"text":25,"correct":26},"B","对压缩机的承压能力要求，两种工质基本一致",false,{"key":28,"text":29,"correct":22},"C","两种工质单位容积的制冷量，R134a约为R123的4.9倍",{"key":31,"text":32,"correct":22},"D","R134a的系统比R123的系统更不容易出现负压","ACD",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":46,"analysis":17},881402,"在同样流量下与其他叶片形式的风机相比，后向式叶片离心风机的特点是( )",[38,40,42,44],{"key":20,"text":39,"correct":26},"同样风量下风压较高",{"key":24,"text":41,"correct":22},"同样风量下风压较低",{"key":28,"text":43,"correct":22},"效率较高",{"key":31,"text":45,"correct":22},"噪声较小","BCD",{"id":48,"libraryId":5,"type":15,"typeLabel":16,"stem":49,"options":50,"answer":59,"analysis":17},881403,"确定围护结构传热阻应满足下列哪些要求？( )",[51,53,55,57],{"key":20,"text":52,"correct":22},"应满足围护结构内表面不结露的要求",{"key":24,"text":54,"correct":22},"应满足卫生要求",{"key":28,"text":56,"correct":26},"应满足环保要求",{"key":31,"text":58,"correct":22},"应满足节能要求","ABD",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":33,"analysis":17},881404,"下列哪几项消防给水设计不符合规范规定？( )",[64,66,68,70],{"key":20,"text":65,"correct":22},"某20层普通住宅楼室内外消火栓的设计用水量相同",{"key":24,"text":67,"correct":26},"某20层普通住宅楼室内外消火栓的设计用水量不同",{"key":28,"text":69,"correct":22},"10层的普通住宅楼与18层普通住宅楼的室外消火栓用水量不同",{"key":31,"text":71,"correct":22},"10层医院住院楼与18层医院住院楼的室内消火栓用水量相同",{"id":73,"libraryId":5,"type":15,"typeLabel":16,"stem":74,"options":75,"answer":84,"analysis":17},881405,"空气源热泵热水机，采用涡旋式压缩机，设其热水的供回水温度不变，当环境温度发生变化时，下列表述正确的应是哪几项?( )。",[76,78,80,82],{"key":20,"text":77,"correct":22},"环境温度升高，表示压缩机的吸气压力升高，压缩比则变小",{"key":24,"text":79,"correct":22},"环境温度升高，表示压缩机的吸气压力升高，压缩机的制冷剂质量流量增加",{"key":28,"text":81,"correct":22},"环境温度升高，制热量增加的幅度大于压缩机功耗的增加，机组的能效比升高",{"key":31,"text":83,"correct":22},"环境温度升高，压缩机吸入制冷剂的比容减小，机组的制热量增大","ABCD",{"id":86,"libraryId":5,"type":15,"typeLabel":16,"stem":87,"options":88,"answer":97,"analysis":17},881406,"下列空调冷热源的说法中，哪些是不正确的？( )",[89,91,93,95],{"key":20,"text":90,"correct":22},"在严寒地区，采用空气源热泵空调仍是一种节能的空调方案",{"key":24,"text":92,"correct":22},"由于太阳能制冷系统不消耗矿物能源，因此在空调系统设计中应尽可能利用太阳能制冷",{"key":28,"text":94,"correct":22},"水源热泵系统利用了地下自然冷热源，因此该空调形式将逐步取代其他系统形式",{"key":31,"text":96,"correct":26},"吸收式冷水机组的一次能耗通常比电动压缩式冷水机组大","ABC",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":110,"analysis":17},881407,"装配式冷库的特点是( )。",[102,104,106,108],{"key":20,"text":103,"correct":26},"隔热防潮不如土建冷库",{"key":24,"text":105,"correct":22},"围护结构采用不锈钢板或涂塑钢板",{"key":28,"text":107,"correct":26},"需建在室内",{"key":31,"text":109,"correct":22},"在工厂预制，现场组装","BD",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":59,"analysis":17},881408,"下列减振措施中，正确的是( )。",[115,117,119,121],{"key":20,"text":116,"correct":22},"水泵采用软木减振",{"key":24,"text":118,"correct":22},"风机进出口采用帆布软管隔振",{"key":28,"text":120,"correct":26},"转速为2900r\u002Fmin的风机采用弹簧减振器",{"key":31,"text":122,"correct":22},"水泵进出口采用金属波纹管隔振",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":46,"analysis":17},881409,"某30层的高层公共建筑，其避难层净面积为1220㎡，需设机械加压送风系统，符合规定的加压送风量是哪几项?( )。",[127,128,129,130],{"key":20,"text":17,"correct":26},{"key":24,"text":17,"correct":22},{"key":28,"text":17,"correct":22},{"key":31,"text":17,"correct":22},{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":143,"analysis":17},881410,"选择闭式热水热力管网补水装置时，做法正确的是( )。",[135,137,139,141],{"key":20,"text":136,"correct":22},"补水装置的流量取系统循环水量的4%",{"key":24,"text":138,"correct":26},"补水装置的流量等于生活热水最大设计流量",{"key":28,"text":140,"correct":22},"设置补水泵2台，无备用",{"key":31,"text":142,"correct":26},"设置补水泵1台","AC",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":33,"analysis":17},881411,"室外空气综合温度与( )有关。",[148,150,152,154],{"key":20,"text":149,"correct":22},"室外空气干球温度",{"key":24,"text":151,"correct":26},"室外空气湿球温度",{"key":28,"text":153,"correct":22},"围护结构外表面吸收系数",{"key":31,"text":155,"correct":22},"太阳辐射照度",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":46,"analysis":17},881412,"下列关于一次回风系统和二次回风系统的表述，正确的是( )。",[160,162,164,166],{"key":20,"text":161,"correct":26},"采用露点送风的一次回风系统，其空调设备夏季的冷风量由室内冷负荷、新风负荷和再热负荷组成",{"key":24,"text":163,"correct":22},"对同一房间采用一次回风系统，在冬季所需的热量与二次回风系统相同",{"key":28,"text":165,"correct":22},"当夏季空调房间需进行再热时，采用二次回风系统可节约再热量",{"key":31,"text":167,"correct":22},"使用表面式换热器与喷水室处理空气的一次回风系统或二次回风系统，在冬季空调设备所需的热量相同",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":180,"analysis":17},881413,"某栋六层住宅建筑，设计热水集中采暖系统，错误的设计做法是下列哪几项？",[172,174,176,178],{"key":20,"text":173,"correct":22},"为保证户内双管系统的流量，热力入口设置定流量调节阀",{"key":24,"text":175,"correct":22},"为保证供暖系统的采暖能力，供暖系统的供回水干管计算，计入向邻户传热引起的耗热量",{"key":28,"text":177,"correct":26},"为延长热计量表使用寿命，将户用热计量表安装在回水管上",{"key":31,"text":179,"correct":26},"为保证热计量表不被堵塞，户用热计量表前设置过滤器","AB",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":97,"analysis":17},881414,"夏季采用空气处理机组的表冷器冷却空气时，通常采用的做法是：将“机器露点”相对湿度确定为90%～95%，而不是100%的相对湿度，采用该做法的原因表述，下列哪些项是错误的？",[185,187,189,191],{"key":20,"text":186,"correct":22},"因空气冷却到相对湿度为90%以上时，会发生结露",{"key":24,"text":188,"correct":22},"空调系统只需要处理到相对湿度为90%～95%",{"key":28,"text":190,"correct":22},"相对湿度采用90%-95%比采用100%更加节能",{"key":31,"text":192,"correct":26},"由于受到表冷器旁通系数的影响，“机器露点”无法实现100%",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":59,"analysis":17},881415,"非单向流气流组织具有的特点的是( )。",[197,199,201,203],{"key":20,"text":198,"correct":22},"由于气流组织方式为乱流方式，室内发生的尘粒等污染物质可向任一方向扩散，所以污染物质的浓度分布可迅速扩散均匀",{"key":24,"text":200,"correct":22},"非单向流式气流组织一般采用上送下回的形式，即送风口位于净化房间的上部，回风口则设在房间的下部，使气流自上而下，与尘粒所受的重力方向一致",{"key":28,"text":202,"correct":26},"由于受送风口形式和布置的限制，洁净度可达到较高级别，但不易维持",{"key":31,"text":204,"correct":22},"采用非单向流式气流组织的洁净室构造简单、施工方便、投资和运行费用较小，大多数洁净室采用此方式",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":33,"analysis":17},881416,"下列净化空调系统对空气过滤器的布置要求中正确的是( )。",[209,211,213,215],{"key":20,"text":210,"correct":22},"粗效过滤器用于过滤大颗粒粒子和各种异物，应设置在空调机组的新风段",{"key":24,"text":212,"correct":26},"中效(高中效)空气过滤器应设置在空调系统的正压段",{"key":28,"text":214,"correct":22},"亚高效和高效过滤器作为末端过滤器时，宜设置在净化空调系统的末端",{"key":31,"text":216,"correct":22},"超高效过滤器必须设置在净化空调系统的末端",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":143,"analysis":17},881417,"我国高效空气过滤器标准中进行分类的主要参数为( )。",[221,223,225,227],{"key":20,"text":222,"correct":22},"阻力",{"key":24,"text":224,"correct":26},"容尘量",{"key":28,"text":226,"correct":22},"过滤效率",{"key":31,"text":228,"correct":26},"风速",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":143,"analysis":17},881418,"下列计算方法中，哪几项不属于空调系统全年耗能量计算方法？",[233,235,237,239],{"key":20,"text":234,"correct":22},"谐波反应法",{"key":24,"text":236,"correct":26},"负荷频率法",{"key":28,"text":238,"correct":22},"冷负荷系数法",{"key":31,"text":240,"correct":26},"满负荷当量运行时间法",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":110,"analysis":17},881419,"关于空调热舒适性的表述中，正确的是( )。",[245,247,249,251],{"key":20,"text":246,"correct":26},"在最佳的热舒适性环境中，所有人都会感到满意",{"key":24,"text":248,"correct":22},"在最佳的热舒适性环境中，从统计平均的角度，还会有5%的人感到不满意",{"key":28,"text":250,"correct":26},"创造最佳的热舒适性环境是空调设计追求的唯一目标",{"key":31,"text":252,"correct":22},"比较理想的空调热舒适性环境是使不满意的人数不大于10%",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":59,"analysis":17},881420,"蒸气压缩式制冷理论循环存在( )。",[257,259,261,263],{"key":20,"text":258,"correct":22},"温差损失",{"key":24,"text":260,"correct":22},"节流损失",{"key":28,"text":262,"correct":26},"过冷损失",{"key":31,"text":264,"correct":22},"过热损失",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":33,"analysis":17},881421,"选择盐水作载冷剂时，为了降低盐水对金属的腐蚀作用，应采用下列哪些措施？( )",[269,271,273,275],{"key":20,"text":270,"correct":22},"配制时选用高纯度的盐",{"key":24,"text":272,"correct":26},"最好采用开式盐水系统",{"key":28,"text":274,"correct":22},"在盐水溶液中加入一定量的重铬酸钠",{"key":31,"text":276,"correct":22},"在盐水溶液中加入一定量的氢氧化钠",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":46,"analysis":17},881422,"热力管道地下敷设时，下列哪些做法是正确的？( )",[281,283,285,287],{"key":20,"text":282,"correct":26},"通行地沟内空气温度不宜超过40℃",{"key":24,"text":284,"correct":22},"不通行地沟宽不宜超过1.5m",{"key":28,"text":286,"correct":22},"热水管道宜采用直埋敷设",{"key":31,"text":288,"correct":22},"半通行地沟管道保温表面与沟底净距离≥0.2m",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":301,"analysis":17},881423,"关于离心式和轴流式通风机，下列说法正确的是( )。",[293,295,297,299],{"key":20,"text":294,"correct":22},"离心式通风机适用于风量较小、系统阻力较大的场合",{"key":24,"text":296,"correct":26},"离心式通风机适用于风量较大、系统阻力较小的场合",{"key":28,"text":298,"correct":26},"轴流式通风机适用于风量较小、系统阻力较大的场合",{"key":31,"text":300,"correct":22},"轴流式通风机适用于风量较大、系统阻力较小的场合","AD",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":84,"analysis":17},881424,"居住建筑集中供暖系统节能，要求调节、计量装置的做法，应是下列哪几项？( )",[306,308,310,312],{"key":20,"text":307,"correct":22},"设置分户温度调节装置",{"key":24,"text":309,"correct":22},"设置分室温度调节装置",{"key":28,"text":311,"correct":22},"设置分户(单元)计量装置",{"key":31,"text":313,"correct":22},"预留分户(单元)计量装置的位置",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":33,"analysis":17},881425,"“供暖度日数”与“供暖期度日数”的区别是( )。",[318,320,322,324],{"key":20,"text":319,"correct":22},"供暖度日数与供暖期的长短无关",{"key":24,"text":321,"correct":26},"两者的室内基准温度的取值不同",{"key":28,"text":323,"correct":22},"供暖度日数按照室外日平均温度与室内基准温度之间的温差计算",{"key":31,"text":325,"correct":22},"供暖度日数的数值一般大于供暖期度日数的数值",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":143,"analysis":17},881426,"某高度25m展厅(单层)的通风空调系统，风管按防火分区设置，且设有排烟防火阀，措施正确的应是下列哪几项？",[330,332,334,336],{"key":20,"text":331,"correct":22},"风管应采用不燃材料",{"key":24,"text":333,"correct":26},"确有困难时，消声材料可以采用燃烧产物毒性较小的难燃材料",{"key":28,"text":335,"correct":22},"风管可采用燃烧产物毒性较小且烟密度等级小于等于25的难燃材料",{"key":31,"text":337,"correct":26},"电加热器前后各2.Om范围内的风管绝热材料应采用不燃材料",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":301,"analysis":17},881427,"保冷(冷保温)材料应具备下列哪几项特性？( )",[342,344,346,348],{"key":20,"text":343,"correct":22},"导热系数小",{"key":24,"text":345,"correct":26},"材料中的气孔应为开孔",{"key":28,"text":347,"correct":26},"氧指数大于30",{"key":31,"text":349,"correct":22},"密度较小",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":143,"analysis":17},881428,"与单效型溴化锂吸收式制冷机组相比，双效型溴化锂吸收式制冷机组( )。",[354,356,358,360],{"key":20,"text":355,"correct":22},"设有高压和低压发生器",{"key":24,"text":357,"correct":26},"热源温度较低",{"key":28,"text":359,"correct":22},"热力系数提高",{"key":31,"text":361,"correct":26},"当制冷量与单效机组相等时，所需冷却水流量增大",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":97,"analysis":17},881429,"与热水混合系数相关的因素有( )。",[366,368,370,372],{"key":20,"text":367,"correct":22},"热设备出水温度",{"key":24,"text":369,"correct":22},"冷水计算温度",{"key":28,"text":371,"correct":22},"冷热水混合后卫生器具的用水温度",{"key":31,"text":373,"correct":26},"热水用水定额",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":180,"analysis":17},881430,"单级蒸汽压缩式制冷循环，压缩机吸入管道存在的压力降，对制冷性能有下列哪几项影响？",[378,380,382,384],{"key":20,"text":379,"correct":22},"致使吸气比容增加",{"key":24,"text":381,"correct":22},"压缩机的压缩比增加",{"key":28,"text":383,"correct":26},"单位容积制冷量增加",{"key":31,"text":385,"correct":26},"系统制冷系数增加",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":97,"analysis":17},881431,"供暖管道热补偿的做法，错误的是( )。",[390,392,394,396],{"key":20,"text":391,"correct":22},"垂直式热水供暖系统供水干管应尽量利用自然补偿，不必设置补偿器",{"key":24,"text":393,"correct":22},"6层住宅楼垂直式热水供暖系统的立管，可不设补偿器",{"key":28,"text":395,"correct":22},"低温水散热器供暖系统，由固定点起100m内的直管段可不装补偿器",{"key":31,"text":397,"correct":26},"中温辐射板供暖时，接向辐射板的支管应考虑伸缩的可能",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":46,"analysis":17},881432,"用液体吸收法净化小于lμm的烟尘时，经技术经济比较后下列哪些吸收装置不宜采用？",[402,404,406,408],{"key":20,"text":403,"correct":26},"文丘管洗涤器",{"key":24,"text":405,"correct":22},"填料塔(逆流)",{"key":28,"text":407,"correct":22},"填料塔(顺流)",{"key":31,"text":409,"correct":22},"旋风洗涤器",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":180,"analysis":17},881433,"关于锅炉房通风量的规定，正确的应是下列哪几项？",[414,416,418,420],{"key":20,"text":415,"correct":22},"燃油锅炉房设置在首层，正常换气次数不少于3次／h",{"key":24,"text":417,"correct":22},"燃气锅炉房设置在首层，正常换气次数不少于6次\u002Fh",{"key":28,"text":419,"correct":26},"锅炉房设置在半地下室，正常换气次数不少于12次\u002Fh",{"key":31,"text":421,"correct":26},"以上换气量中包括锅炉燃烧所需空气量",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":84,"analysis":17},881434,"一般全空气空调系统不宜采用冬、夏季能耗较大的直流(全新风)空调系统，但是在“个别情况”下应采用直流(全新风)空调系统。“个别情况”是下列哪几项？( )",[426,428,430,432],{"key":20,"text":427,"correct":22},"室内散发有害物质，以及防火防爆等要求不允许空气循环使用",{"key":24,"text":429,"correct":22},"夏季空调系统的回风比焓高于室外空气",{"key":28,"text":431,"correct":22},"系统服务的各空调区排风量大于按负荷计算出的送风量",{"key":31,"text":433,"correct":22},"各空调区采用风机盘管，集中送新风的系统",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":46,"analysis":17},881435,"改变通风机特性曲线的调节方法有( )。",[438,440,442,444],{"key":20,"text":439,"correct":26},"减少或增加管网系统的压力损失",{"key":24,"text":441,"correct":22},"改变通风机进口导流叶片角度",{"key":28,"text":443,"correct":22},"改变风机叶轮的转速",{"key":31,"text":445,"correct":22},"风机并联",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":46,"analysis":17},881436,"下列可以用作液体吸湿剂的是( )。",[450,452,454,456],{"key":20,"text":451,"correct":26},"乙二醇溶液",{"key":24,"text":453,"correct":22},"氯化钙溶液",{"key":28,"text":455,"correct":22},"氯化锂溶液",{"key":31,"text":457,"correct":22},"三甘醇",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":110,"analysis":17},881437,"在有强热源的车间内，有效热量系数m值的表述中，下列哪几项是正确的？( )",[462,464,466,468],{"key":20,"text":463,"correct":26},"随着热源的辐射散热量和总热量比值变大，m值变小",{"key":24,"text":465,"correct":22},"随着热源高度变大，m值变小",{"key":28,"text":467,"correct":26},"随着热源占地面积和地板面积比值变小，m值变大",{"key":31,"text":469,"correct":22},"在其他条件相同时，热源布置得越分散，m值变大",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":97,"analysis":17},881438,"在选择和布置通风设备时，下列哪几项是正确的？( )",[474,476,478,480],{"key":20,"text":475,"correct":22},"空气中含有易燃易爆物质的房间中的送风系统应采用防爆设备",{"key":24,"text":477,"correct":22},"甲、乙类厂房的排风设备，不应与其他房间的排风设备布置在同一通风机房内",{"key":28,"text":479,"correct":22},"排除有爆炸危险的粉尘的局部排风系统分组布置",{"key":31,"text":481,"correct":26},"甲、乙类生产厂房全面排风系统的设备可布置在有外窗的半地下室内",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":33,"analysis":17},881439,"关于二级泵供回水总管间压差旁通阀的说法，下列哪些项是正确的？( )",[486,488,490,492],{"key":20,"text":487,"correct":22},"二级泵采用变速控制时，宜设置压差旁通阀",{"key":24,"text":489,"correct":26},"二级泵采用台数控制时，宜设置压差旁通阀",{"key":28,"text":491,"correct":22},"二级泵采用台数控制时，旁通阀的设计流量为一台定速泵的设计流量",{"key":31,"text":493,"correct":22},"二级泵采用变速控制时，旁通阀的设计流量为一台变速泵的最小流量",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":496,"answer":143,"analysis":17},881440,[497,499,501,503],{"key":20,"text":498,"correct":22},"管道材料",{"key":24,"text":500,"correct":26},"管壁厚度",{"key":28,"text":502,"correct":22},"使用条件分级",{"key":31,"text":504,"correct":26},"管道直径",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":143,"analysis":17},881441,"当通风机输送的空气密度减小时，下列说法哪几项是正确的？( )",[509,511,513,515],{"key":20,"text":510,"correct":22},"风机消耗的功率减小",{"key":24,"text":512,"correct":26},"风机的效率减小",{"key":28,"text":514,"correct":22},"风机的全压减小",{"key":31,"text":516,"correct":26},"风机的风量减小",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":301,"analysis":17},881442,"《人民防空地下室设计规范》中规定了进风口部的管道连接的正确设计要求，设计中进风口部的通风管由扩散室侧墙穿入和由扩散室后墙穿入的四组做法，管道连接方式不符合规范规定的应是下列选项中的哪几项？",[521,522,523,524],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":26},{"key":28,"text":17,"correct":26},{"key":31,"text":17,"correct":22},{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":536,"analysis":17},881443,"下列关于旋风除尘器、袋式除尘器和静电除尘器性能的叙述，哪几项是正确的？( )",[529,531,533,535],{"key":20,"text":530,"correct":26},"旋风除尘器的分割粒径越大，旋风除尘器的效率越高",{"key":24,"text":532,"correct":22},"旋风除尘器的压力损失与其进口速度的平方成正比",{"key":28,"text":534,"correct":22},"袋式除尘器过滤层的压力损失与过滤速度成正比",{"key":31,"text":17,"correct":26},"BC",{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":33,"analysis":17},881444,"冷库的冷负荷主要包括( )。",[541,543,545,547],{"key":20,"text":542,"correct":22},"围护结构的热流量",{"key":24,"text":544,"correct":26},"压缩机能耗",{"key":28,"text":546,"correct":22},"冷库内电器设备的能耗",{"key":31,"text":548,"correct":22},"库内货物的呼吸热",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":110,"analysis":17},881445,"高层建筑采用液化石油气作燃料的负压锅炉，允许布置在下列哪些位置？( )",[553,555,557,559],{"key":20,"text":554,"correct":26},"建筑物的地下二层",{"key":24,"text":556,"correct":22},"高层建筑外的专用房间内",{"key":28,"text":558,"correct":26},"建筑物的地下一层",{"key":31,"text":560,"correct":22},"处于地上非人员密集场所的上一层、下一层或贴邻建筑",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":59,"analysis":17},881446,"下列关于自动喷水灭火系统的水流指示器设置的说法，正确的是( )。",[565,567,569,571],{"key":20,"text":566,"correct":22},"每个防火分区应设",{"key":24,"text":568,"correct":22},"每个楼层均应设",{"key":28,"text":570,"correct":26},"设于每个防火分区最不利喷头处",{"key":31,"text":572,"correct":22},"水流指示器入口前设置控制阀时，应采用信号阀",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":301,"analysis":17},881447,"关于平衡阀，下列哪些说法是正确的？( )",[577,579,581,583],{"key":20,"text":578,"correct":22},"建议安装在回水管路上",{"key":24,"text":580,"correct":26},"平衡阀前应安装起关闭作用的截止阀",{"key":28,"text":582,"correct":26},"平衡阀后应安装起关闭作用的截止阀",{"key":31,"text":584,"correct":22},"尽可能安装在直管段上",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":143,"analysis":17},881448,"下列哪些写法与制冷剂标识符号HFC-32\u002FHFC-125\u002FHFC-134a(23\u002F25\u002F52)相当？( )",[589,591,593,595],{"key":20,"text":590,"correct":22},"R407C",{"key":24,"text":592,"correct":26},"R407B",{"key":28,"text":594,"correct":22},"R32\u002FR125\u002FR134a(23\u002F25\u002F52)",{"key":31,"text":596,"correct":26},"R410A",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":59,"analysis":17},881449,"通过( )方式可以降低围护结构的传热系数。",[601,603,605,607],{"key":20,"text":602,"correct":22},"在围护结构中安装空气间层",{"key":24,"text":604,"correct":22},"在墙体外面加保温材料",{"key":28,"text":606,"correct":26},"增加室内空气温度",{"key":31,"text":608,"correct":22},"顶棚安装肋状的突出物",{"id":610,"libraryId":5,"type":15,"typeLabel":16,"stem":611,"options":612,"answer":46,"analysis":17},881450,"进行蒸汽供暖系统水力计算时，应注意( )。",[613,615,617,619],{"key":20,"text":614,"correct":26},"高压蒸汽最不利环路供汽管的压力损失不应大于起始压力的30%",{"key":24,"text":616,"correct":22},"低压蒸汽供暖系统到达散热器入口前应留有1500～2000Pa的剩余压力",{"key":28,"text":618,"correct":22},"高压蒸汽供暖系统的供汽压力高于系统的工作压力时，应在入口的供汽管道上装设减压装置",{"key":31,"text":620,"correct":22},"高压蒸汽最不利环路供汽管的压力损失不应大于起始压力的25%",[622,626,629,632,635,638],{"id":623,"name":624,"category":7,"favorite":625},1,"领导干部任职前廉政法规知识测试题",92,{"id":627,"name":628,"category":7,"favorite":623},595,"建筑结构与设备",{"id":630,"name":631,"category":7,"favorite":623},715,"招标采购专业知识与法律法规",{"id":633,"name":634,"category":7,"favorite":623},848,"市政方向-通用基础",{"id":636,"name":637,"category":7,"favorite":8},534,"BIM工程师",{"id":639,"name":637,"category":7,"favorite":8},535]