[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-31":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":626},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,31,50,2054,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,234,246,258,270,282,294,306,318,330,342,354,366,378,390,402,414,426,438,450,462,474,489,502,514,527,540,552,564,577,590,602,614],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},881351,1,"单选题","下列哪一项供暖建筑的热负荷计算方法是错误的？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","风力附加只对不避风的垂直外围护结构在基本耗热量上作附加，但对其余也应在垂直投影面的基本耗热量上作附加",false,{"key":24,"text":25,"correct":26},"B","工业建筑渗透冷空气耗热量附加率是基于全部围护结构基本耗热量",true,{"key":28,"text":29,"correct":22},"C","多层建筑的渗透冷空气耗热量，当无相关数据时，可按规定的换气次数计算",{"key":31,"text":32,"correct":22},"D","外门附加率只适应于短时间开启的、无热风幕的外门","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},881352,"锅炉的尾部受热面是指( )。",[38,40,42,44],{"key":20,"text":39,"correct":22},"蒸汽过热器、省煤器和空气预热器",{"key":24,"text":41,"correct":22},"蒸汽过热器和空气预热器",{"key":28,"text":43,"correct":22},"蒸汽过热器和省煤器",{"key":31,"text":45,"correct":26},"省煤器和空气预热器",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},881353,"甲、乙两台压缩机分别在GB\u002FT10079-2001《活塞式单级制冷压缩机》规定的高冷凝压力工况和低冷凝压力工况下工作时耗功相等，则在各自工况下的制冷量( )。",[50,52,54,56],{"key":20,"text":51,"correct":22},"甲大于乙",{"key":24,"text":53,"correct":26},"乙大于甲",{"key":28,"text":55,"correct":22},"相等",{"key":31,"text":57,"correct":22},"与制冷剂有关",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},881354,"一般净化空调系统，配置空气过滤器为粗效过滤器、中效过滤器(或高中效过滤器)、末级过滤器(亚高效或高效过滤器)。中效过滤器或高中效过滤器宜集中设置在( )。",[62,64,66,68],{"key":20,"text":63,"correct":22},"空调系统的负压段",{"key":24,"text":65,"correct":26},"空调系统的正压段",{"key":28,"text":67,"correct":22},"送风管上",{"key":31,"text":69,"correct":22},"送风口处",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},881355,"制冷压缩机采用高低压旁通阀进行能量调节时，下列哪一项是正确的？( )",[74,76,78,80],{"key":20,"text":75,"correct":22},"简单可行",{"key":24,"text":77,"correct":22},"可行，但要注意回油问题",{"key":28,"text":79,"correct":22},"可行，但要注意排气温度过高",{"key":31,"text":81,"correct":26},"高低压差太大，不易调节",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},881356,"大、中型冷库氨制冷系统经常使用的冷凝器是( )。",[86,88,90,92],{"key":20,"text":87,"correct":22},"蒸发式冷凝器",{"key":24,"text":89,"correct":22},"卧式壳管式冷凝器",{"key":28,"text":91,"correct":26},"立式壳管式冷凝器",{"key":31,"text":93,"correct":22},"套管式冷凝器",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},881357,"设备间溴化锂吸收式制冷机之间间距应不小于( )，溴化锂吸收式制冷剂与墙之间应不小于( )。",[98,100,102,104],{"key":20,"text":99,"correct":26},"1.5m，1.2m",{"key":24,"text":101,"correct":22},"1.2m，1.5m",{"key":28,"text":103,"correct":22},"1.0m，1.2m",{"key":31,"text":105,"correct":22},"1.2m，1.0m",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},881358,"对排除含尘空气的局部排风系统，当排风经净化后下列哪个论断是正确的？( )",[110,112,114,116],{"key":20,"text":111,"correct":22},"可以循环使用",{"key":24,"text":113,"correct":22},"不可以循环使用",{"key":28,"text":115,"correct":22},"净化后含尘浓度＞10%工作区容许浓度时不可以循环使用",{"key":31,"text":117,"correct":26},"净化后含尘浓度≥30%工作区容许浓度时不可以循环使用",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},881359,"关于氟利昂系统管路设计，下列说法不正确的是( )。",[122,124,126,128],{"key":20,"text":123,"correct":26},"压缩机的吸气水平管道应有≥0.02的坡度，坡向蒸发器",{"key":24,"text":125,"correct":22},"压缩机的排气水平管道应有≥0.01的坡度，坡向油分离器或冷凝器",{"key":28,"text":127,"correct":22},"冷凝器到贮液器的水平管道应有≥0.01的坡度，坡向贮液器",{"key":31,"text":129,"correct":22},"多台压缩机并联使用时，为保证负荷较小时吸气立管内制冷剂有足够大的流速，应采用双吸气竖管",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},881360,"蒸发式冷凝器应布置在通风良好之处，与邻近建筑物应有一定的距离，顶部应高出邻近建筑物( )，水盘底离地( )。",[134,136,138,140],{"key":20,"text":135,"correct":22},"300mm，大于500mm",{"key":24,"text":137,"correct":26},"300mm，小于500mm",{"key":28,"text":139,"correct":22},"300mm，小于400mm",{"key":31,"text":141,"correct":22},"300mm，大于400mm",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},881361,"某大型建筑物空调的最大负荷和最小负荷差值较大，下列冷水机组设置方案中比较合理的是( )。",[146,148,150,152],{"key":20,"text":147,"correct":26},"3台螺杆式冷水机组，两大一小",{"key":24,"text":149,"correct":22},"2台容量相同的离心式冷水机组",{"key":28,"text":151,"correct":22},"3台容量相同的螺杆冷水机组",{"key":31,"text":153,"correct":22},"4台容量相同的螺杆冷水机组",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":28,"analysis":33},881362,"室外高压过热蒸汽管道同一坡向的直线管段上，在顺坡情况下设疏水装置的间距应为下列哪一项？( )",[158,160,162,164],{"key":20,"text":159,"correct":22},"200m＜L≤300m",{"key":24,"text":161,"correct":22},"300m＜L≤400m",{"key":28,"text":163,"correct":26},"400m＜L≤500m",{"key":31,"text":165,"correct":22},"500m＜L≤1000m",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},881363,"在风机盘管加新风空调系统中，从节能角度考虑，下列新风送入方式中，( )是不可取的。",[170,172,174,176],{"key":20,"text":171,"correct":22},"新风单独送入室内",{"key":24,"text":173,"correct":26},"新风送入风机盘管回风箱中",{"key":28,"text":175,"correct":22},"新风送入吊顶内",{"key":31,"text":177,"correct":22},"新风送入走廊内",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":31,"analysis":33},881364,"下列关于粉尘沉降速度的描述中，正确的是( )。",[182,184,186,188],{"key":20,"text":183,"correct":22},"粉尘的下落速度",{"key":24,"text":185,"correct":22},"粉尘下落过程中的平均速度",{"key":28,"text":187,"correct":22},"计算时段内粉尘下落达到的最大速度",{"key":31,"text":189,"correct":26},"粉尘在静止空气中自由降落所达到的最大速度",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":24,"analysis":33},881365,"热风供暖系统中，空气加热器中空气的质量流速宜取( )。",[194,196,198,200],{"key":20,"text":195,"correct":22},"1～3kg\u002F(㎡·s)",{"key":24,"text":197,"correct":26},"3～8kg\u002F(㎡·s)",{"key":28,"text":199,"correct":22},"1～3m\u002Fs",{"key":31,"text":201,"correct":22},"3～8m\u002Fs",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":31,"analysis":33},881366,"净化空调系统与一般空调系统在设计、施工、运行管理上有很大区别，其中，送风、回风、排风系统启闭按先后进行连锁控制，其目的是为了( )。",[206,208,210,212],{"key":20,"text":207,"correct":22},"自动开机和关机",{"key":24,"text":209,"correct":22},"事故显示",{"key":28,"text":211,"correct":22},"保证自净时间",{"key":31,"text":213,"correct":26},"在系统开机和停机时，保证洁净室内的压差，防止造成污染",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":28,"analysis":33},881367,"高层民用建筑中庭采用自然排烟应符合的条件是( )。",[218,220,222,224],{"key":20,"text":219,"correct":22},"天窗或高侧窗的面积不应小于该中庭地面面积的2%",{"key":24,"text":221,"correct":22},"天窗或高侧窗的面积不应小于该中庭地面面积的5%",{"key":28,"text":223,"correct":26},"净空高度小于12m的中庭可开启的天窗或高侧窗的面积不应小于该中庭地面面积的5%",{"key":31,"text":225,"correct":22},"净空高度小于12m的中庭可开启的天窗或高侧窗的面积不小于该中庭地面面积的2%",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":28,"analysis":33},881368,"高层民用建筑使用燃油作燃料时，其油罐总储量不应超过( )。",[230,231,232,233],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":26},{"key":31,"text":33,"correct":22},{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":31,"analysis":33},881369,"用于排除氢气与空气混合物时，建筑物全面排风系统的吸风口上缘至顶棚平面或屋顶的距离( )。",[238,240,242,244],{"key":20,"text":239,"correct":22},"不小于0.4m",{"key":24,"text":241,"correct":22},"不小于0.1m",{"key":28,"text":243,"correct":22},"不大于0.4m",{"key":31,"text":245,"correct":26},"不大于0.1m",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":28,"analysis":33},881370,"文丘里除尘器是一种( )。",[250,252,254,256],{"key":20,"text":251,"correct":22},"旋风除尘器",{"key":24,"text":253,"correct":22},"袋式除尘器",{"key":28,"text":255,"correct":26},"湿式除尘器",{"key":31,"text":257,"correct":22},"静电除尘器",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":28,"analysis":33},881371,"围护结构热阻的单位是( )。",[262,264,266,268],{"key":20,"text":263,"correct":22},"W／(m？℃)",{"key":24,"text":265,"correct":22},"W／(㎡？℃)",{"key":28,"text":267,"correct":26},"(㎡？℃)／W",{"key":31,"text":269,"correct":22},"(m？℃)／W",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":31,"analysis":33},881372,"洁净空调风管系统允许漏风率(漏风量\u002F设计风量)与气流流型有关，单向流系统允许的漏风率≤1%，非单向流系统允许的漏风率为( )。",[274,276,278,280],{"key":20,"text":275,"correct":22},"≤1.2%",{"key":24,"text":277,"correct":22},"≤1.5%",{"key":28,"text":279,"correct":22},"≤1.8%",{"key":31,"text":281,"correct":26},"≤2.O%",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":31,"analysis":33},881373,"某高层住宅用户燃气表的安装位置，做法符合要求的应是下列何项?( )。",[286,288,290,292],{"key":20,"text":287,"correct":22},"安装在更衣室内",{"key":24,"text":289,"correct":22},"安装在高层建筑避难层",{"key":28,"text":291,"correct":22},"安装在防烟楼梯间内",{"key":31,"text":293,"correct":26},"安装在有开启外窗的封闭生活阳台内",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":24,"analysis":33},881374,"某供暖房间三个朝向有外围护物，计算该房间的热负荷时，应( )。",[298,300,302,304],{"key":20,"text":299,"correct":22},"计算所有朝向外窗的冷空气耗热量",{"key":24,"text":301,"correct":26},"计算冷空气渗透较大两个朝向外窗的冷空气耗热量",{"key":28,"text":303,"correct":22},"计算冷空气渗透较大一个朝向外窗的冷空气耗热量",{"key":31,"text":305,"correct":22},"计算冬季较多风向围护结构1\u002F2范围内外窗的冷空气耗热量",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":24,"analysis":33},881375,"排除有爆炸危险气体、蒸汽和粉尘的局部排风系统的风量应按正常运行和事故情况下风管内这些物质的哪种浓度计算？( )",[310,312,314,316],{"key":20,"text":311,"correct":22},"不大于爆炸下限",{"key":24,"text":313,"correct":26},"不大于爆炸下限的50%",{"key":28,"text":315,"correct":22},"不大于爆炸上限",{"key":31,"text":317,"correct":22},"不大于爆炸上限的50%",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":24,"analysis":33},881376,"下列冷水机组等产品的选项组中，不符合节能设计标准要求的为哪一项？",[322,324,326,328],{"key":20,"text":323,"correct":22},"选用能效等级为2级的单元式空调机",{"key":24,"text":325,"correct":26},"选用能效等级为4级的水冷式离心冷水机组",{"key":28,"text":327,"correct":22},"选用能效等级为3级的风冷活塞／涡旋式冷水机组",{"key":31,"text":329,"correct":22},"选用能效等级为3级的水冷螺杆式冷水机组",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":24,"analysis":33},881377,"溴化锂吸收式制冷机的冷却水系统串联时，冷却塔应选用( )。",[334,336,338,340],{"key":20,"text":335,"correct":22},"低温型",{"key":24,"text":337,"correct":26},"中温型",{"key":28,"text":339,"correct":22},"逆流型",{"key":31,"text":341,"correct":22},"横流型",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":28,"analysis":33},881378,"下列全空气空调系统空气过滤器选择方法中正确的是( )。",[346,348,350,352],{"key":20,"text":347,"correct":22},"粗效过滤器的初阻力不大于60Pa",{"key":24,"text":349,"correct":22},"中效过滤器的初阻力不大于100Pa",{"key":28,"text":351,"correct":26},"粗效过滤器的初阻力不大于50Pa",{"key":31,"text":353,"correct":22},"中效过滤器的初阻力不大于90Pa",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":28,"analysis":33},881379,"某风机盘管在水系统中承受的实际工作压力为1.0MPa，在对其配置电动两通调节阀时，下列哪一项是电动两通阀关阀压差△p的选择依据之一？( )",[358,360,362,364],{"key":20,"text":359,"correct":22},"△p≥1.5×1.0MPa",{"key":24,"text":361,"correct":22},"△p≥1.0MPa",{"key":28,"text":363,"correct":26},"两通阀两侧的压差",{"key":31,"text":365,"correct":22},"两通阀阀体的承压值",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":31,"analysis":33},881380,"新《洁净规范》规定，洁净室设计确定的空气洁净度等级所处状态为( )。",[370,372,374,376],{"key":20,"text":371,"correct":22},"空态",{"key":24,"text":373,"correct":22},"静态",{"key":28,"text":375,"correct":22},"动态",{"key":31,"text":377,"correct":26},"与业主协商确定的状态",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":24,"analysis":33},881381,"下列有关除尘器问题的描述，何项是错误的?( )。",[382,384,386,388],{"key":20,"text":383,"correct":22},"旋风除尘器灰斗的卸料阀漏风率为5%，会导致除尘器效率大幅下降",{"key":24,"text":385,"correct":26},"经实测袋式除尘器壳体漏风率为3%，是导致除尘效率下降的主要原因",{"key":28,"text":387,"correct":22},"袋式除尘器的个别滤袋破损，是导致除尘器效率大幅下降的原因",{"key":31,"text":389,"correct":22},"袋式除尘器的滤袋积灰过多，会增大滤袋的阻力，并使系统的风量变小",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":31,"analysis":33},881382,"下列关于绿色工业建筑运用的暖通空调技术，错误的是哪一项?( )。",[394,396,398,400],{"key":20,"text":395,"correct":22},"风机、水泵等输送流体的公用设备应合理采用流量调节措施",{"key":24,"text":397,"correct":22},"工艺性空调系统的设计是以保证工艺要求和人员健康为主，室内人员的舒适感处于次要位置",{"key":28,"text":399,"correct":22},"工业厂房的通风设计必须合理的确定建筑朝向和进、排风口位置",{"key":31,"text":401,"correct":26},"建筑和供暖和空调应优先采用地源(利用土壤、江河湖水、污水、海水等)热泵",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":31,"analysis":33},881383,"有关蓄冷的表述中，下列哪一项是错误的？",[406,408,410,412],{"key":20,"text":407,"correct":22},"冰蓄冷系统采用冰槽下游的方案时，所需冰槽的容量应大于冰槽上游的方案",{"key":24,"text":409,"correct":22},"夜间蓄冷时，机载冷水机组的COP值高于白天运行的COP值",{"key":28,"text":411,"correct":22},"冰蓄冷系统的冷机总容量不大于常规系统的总冷机容量",{"key":31,"text":413,"correct":26},"冰蓄冷系统虽然在末端用户处未节能，但对于大量使用核能发电的电网具有节能效果",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":31,"analysis":33},881384,"住宅分户热计量是计量与节能技术的综合，对下列各种共用立管分户热水供暖、计量系统技术方案进行比较，哪项效果最差?( )。",[418,420,422,424],{"key":20,"text":419,"correct":22},"水平双管系统，每组散热器供水支管上设高阻力恒温控制阀，户用热量表法计量",{"key":24,"text":421,"correct":22},"水平单管系统，在户系统人口处设户温控制器，通断时间面积法计量",{"key":28,"text":423,"correct":22},"水平单管跨越式系统，每组散热器供水支管上设低阻力三通恒温控制阀，户用热量表法计量",{"key":31,"text":425,"correct":26},"低温热水地板辐射供暖系统，在各户系统入口处设户温控制器，在分集水器的各支路安装手动流量调节阀，通断时间面积法计量",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":20,"analysis":33},881385,"空调水系统阀门设计原则中，正确的是( )。",[430,432,434,436],{"key":20,"text":431,"correct":26},"为了节能，应尽可能减少最不利环路串联阀门数量",{"key":24,"text":433,"correct":22},"为了调控方便，应尽可能增加阀门数量",{"key":28,"text":435,"correct":22},"为了水力平衡和稳定性，应采用高阻力阀门",{"key":31,"text":437,"correct":22},"为了节能，应采用低阻力阀门",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":24,"analysis":33},881386,"当外网的静压线低于用户的充水高度时，用户与外网可考虑下列哪种连接方式？( )",[442,444,446,448],{"key":20,"text":443,"correct":22},"直接连接",{"key":24,"text":445,"correct":26},"间接连接",{"key":28,"text":447,"correct":22},"直接连接，回水管设加压泵",{"key":31,"text":449,"correct":22},"加混水泵的直接连接",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":20,"analysis":33},881387,"某单层厂房设计工艺性空调，采用全空气系统。冬季通过蒸汽加热，干蒸汽加湿处理空气。室内设计参数：24℃、60%；运行时，室内相对湿度低于设计要求。下列哪一项不会造成该问题发生？",[454,456,458,460],{"key":20,"text":455,"correct":26},"新风阀开度小于设计值",{"key":24,"text":457,"correct":22},"加湿器阀门设置有误",{"key":28,"text":459,"correct":22},"厂房外门、外窗不严密",{"key":31,"text":461,"correct":22},"新风量超过设计值",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":28,"analysis":33},881388,"关于袋式除尘器的说法，下列哪一项是错误的？( )",[466,468,470,472],{"key":20,"text":467,"correct":22},"清洁滤布的压力损失一般比使用中的滤料层压力损失低得多",{"key":24,"text":469,"correct":22},"压力损失与过滤风速有关",{"key":28,"text":471,"correct":26},"采用针刺滤料时，可采用机械振动清灰",{"key":31,"text":473,"correct":22},"采用涤纶纤维滤料时，袋式除尘器应用于排气温度为140℃的场合",{"id":475,"libraryId":5,"type":476,"typeLabel":477,"stem":478,"options":479,"answer":488,"analysis":33},881389,2,"多选题","确定居住区供暖室外管网管道管径的原则是( )。",[480,482,484,486],{"key":20,"text":481,"correct":26},"主干线按照经济比摩阻，分支管线按照与主干线接点处的许用压差",{"key":24,"text":483,"correct":22},"均按照经济比摩阻",{"key":28,"text":485,"correct":22},"均按照最不利环路的许用压差",{"key":31,"text":487,"correct":26},"均不应超过限定流速","AD",{"id":490,"libraryId":5,"type":476,"typeLabel":477,"stem":491,"options":492,"answer":501,"analysis":33},881390,"下列关于全空气变风量空调系统的表述中，正确的是( )。",[493,495,497,499],{"key":20,"text":494,"correct":22},"风量越小能耗也越小，因此不应对变风量系统的最小风量进行限制",{"key":24,"text":496,"correct":26},"室内相对湿度控制质量较差",{"key":28,"text":498,"correct":26},"变风量空调系统每个房间的新风量不能单独调节控制",{"key":31,"text":500,"correct":22},"由于变风量空调系统室内送风量可以独立控制，因此内外区没有必要分开设置","BC",{"id":503,"libraryId":5,"type":476,"typeLabel":477,"stem":504,"options":505,"answer":501,"analysis":33},881391,"对采用铜管、95℃\u002F70℃热水的供暖系统，水压试验压力的要求是( )。",[506,508,510,512],{"key":20,"text":507,"correct":22},"工作压力的1.5倍",{"key":24,"text":509,"correct":26},"系统顶点工作压力加0.1MPa",{"key":28,"text":511,"correct":26},"系统顶点的试验压力不小于0.3MPa",{"key":31,"text":513,"correct":22},"不小于0.6MPa",{"id":515,"libraryId":5,"type":476,"typeLabel":477,"stem":516,"options":517,"answer":526,"analysis":33},881392,"下列关于风机选择的表述中，不正确的是( )。",[518,520,522,524],{"key":20,"text":519,"correct":26},"选择风机的风量时应考虑15%的安全系数",{"key":24,"text":521,"correct":26},"由于管道式风机接管方便，不占机房面积，因此应尽量采用管道式风机",{"key":28,"text":523,"correct":22},"在低气压的高原地区，风机的全压减小",{"key":31,"text":525,"correct":26},"关小支干管风阀，系统阻力增加，风机的能耗也一定增加","ABD",{"id":528,"libraryId":5,"type":476,"typeLabel":477,"stem":529,"options":530,"answer":539,"analysis":33},881393,"下列哪几项高层建筑加压送风系统的设计要求是正确的？( )",[531,533,535,537],{"key":20,"text":532,"correct":26},"防烟楼梯间的正压力应为40～50Pa，加压风口宜每隔2～3层设置一个",{"key":24,"text":534,"correct":22},"一个剪刀楼梯间应分别设置两个加压送风系统",{"key":28,"text":536,"correct":26},"层数超过32层的防烟楼梯间，其送风系统和送风量应分段设计",{"key":31,"text":538,"correct":22},"设加压送风的防烟楼梯间，其无外窗的前室应设加压送风系统","AC",{"id":541,"libraryId":5,"type":476,"typeLabel":477,"stem":542,"options":543,"answer":526,"analysis":33},881394,"关于风机盘管空调水系统阻力计算，下列表述正确的是( )。",[544,546,548,550],{"key":20,"text":545,"correct":26},"循环水泵扬程取10%的安全因数",{"key":24,"text":547,"correct":26},"在确定循环水泵扬程时应按夏季工况进行系统阻力计算",{"key":28,"text":549,"correct":22},"管道局部阻力取10%的安全因数",{"key":31,"text":551,"correct":26},"应考虑风机盘管两通调节阀门全部开启状态时的管道阻力",{"id":553,"libraryId":5,"type":476,"typeLabel":477,"stem":554,"options":555,"answer":526,"analysis":33},881395,"采用自然通风计算方法的一系列简化条件是( )。",[556,558,560,562],{"key":20,"text":557,"correct":26},"空气流动是稳定的，影响自然通风的因素不随时间变化",{"key":24,"text":559,"correct":26},"这个空间空气温度是车间的平均温度",{"key":28,"text":561,"correct":22},"考虑经外围护结构渗入的空气量",{"key":31,"text":563,"correct":26},"空间内无任何障碍影响空气流动",{"id":565,"libraryId":5,"type":476,"typeLabel":477,"stem":566,"options":567,"answer":576,"analysis":33},881396,"某城市建筑住宅区集中供热系统，选用下列哪几项热媒的温度范围最合理？",[568,570,572,574],{"key":20,"text":569,"correct":22},"150～70℃热水",{"key":24,"text":571,"correct":22},"130～70℃热水",{"key":28,"text":573,"correct":26},"110～70℃热水",{"key":31,"text":575,"correct":26},"95～70℃热水","CD",{"id":578,"libraryId":5,"type":476,"typeLabel":477,"stem":579,"options":580,"answer":589,"analysis":33},881397,"为了节约用水，建筑给水系统采用了一些节水措施，下列哪几项措施是正确的？",[581,583,585,587],{"key":20,"text":582,"correct":26},"选用每次用水量少的卫生洁具",{"key":24,"text":584,"correct":26},"分户设置水表",{"key":28,"text":586,"correct":26},"选用具有“无效时自动停水”功能沐浴器",{"key":31,"text":588,"correct":26},"选用手控冲洗流量的大便器","ABCD",{"id":591,"libraryId":5,"type":476,"typeLabel":477,"stem":592,"options":593,"answer":501,"analysis":33},881398,"设计局部排风罩时，应遵循的原则是( )。",[594,596,598,600],{"key":20,"text":595,"correct":22},"在可能条件下，应当首先考虑采用密闭罩或外部吸气罩，使有害物局限于较小的空间，节省风量",{"key":24,"text":597,"correct":26},"局部排风罩应尽可能包围或靠近有害物发生源，使有害物局限于较小的空间，尽可能减小其吸气范围，以便于捕集和控制",{"key":28,"text":599,"correct":26},"在工艺操作条件许可的情况下，罩的四周应当尽量设置围挡，以减小罩口的吸气范围",{"key":31,"text":601,"correct":22},"排风罩的吸气气流方向应尽可能与污染气流运动方向相反",{"id":603,"libraryId":5,"type":476,"typeLabel":477,"stem":604,"options":605,"answer":501,"analysis":33},881399,"热水热力网支干线的设计中，正确的设计应是下列选项中的哪几项？",[606,608,610,612],{"key":20,"text":607,"correct":22},"热力网支干线管径应按经济比摩阻确定",{"key":24,"text":609,"correct":26},"热力网支干线管径应按允许压力降确定",{"key":28,"text":611,"correct":26},"DN400以上的管道的允许比摩阻不应大于300Pa\u002Fm",{"key":31,"text":613,"correct":22},"DN400以下的管道的管内流速不应小于3.5m\u002Fs",{"id":615,"libraryId":5,"type":476,"typeLabel":477,"stem":616,"options":617,"answer":526,"analysis":33},881400,"室内排水系统可以采用的管材有( )。",[618,620,622,624],{"key":20,"text":619,"correct":26},"硬聚氯乙烯塑料管",{"key":24,"text":621,"correct":26},"聚乙烯塑料管",{"key":28,"text":623,"correct":22},"砂模铸造铸铁管",{"key":31,"text":625,"correct":26},"柔性接口机制铸铁管",[627,630,633,636,639,642],{"id":15,"name":628,"category":7,"favorite":629},"领导干部任职前廉政法规知识测试题",92,{"id":631,"name":632,"category":7,"favorite":15},595,"建筑结构与设备",{"id":634,"name":635,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":637,"name":638,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":640,"name":641,"category":7,"favorite":8},534,"BIM工程师",{"id":643,"name":641,"category":7,"favorite":8},535]