[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-30":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":603},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,30,50,2054,[13,32,44,56,67,79,88,100,112,124,136,148,160,172,184,196,208,220,227,239,251,263,275,287,299,311,323,335,347,355,365,377,389,401,413,425,437,448,460,472,484,496,508,520,532,544,556,567,579,591],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":31,"analysis":21},881301,2,"多选题","单级蒸气压缩式制冷循环热力计算需要的温度工况有( )。",[19,23,25,29],{"key":20,"text":21,"correct":22},"A","",true,{"key":24,"text":21,"correct":22},"B",{"key":26,"text":27,"correct":28},"C","压缩机排气温度",false,{"key":30,"text":21,"correct":22},"D","ABD",{"id":33,"libraryId":5,"type":34,"typeLabel":35,"stem":36,"options":37,"answer":24,"analysis":21},881302,1,"单选题","在对新风量进行控制时，如果用比焓参数作为工况转换依据的，即比较新风空气和回风空气的比焓值，当前者的比焓大于后者时，即进行工况的转换。这种控制方法称为( )。",[38,40,42],{"key":20,"text":39,"correct":28},"温度自动再调控制",{"key":24,"text":41,"correct":22},"焓值经济运行控制",{"key":26,"text":43,"correct":28},"自动补偿控制",{"id":45,"libraryId":5,"type":34,"typeLabel":35,"stem":46,"options":47,"answer":30,"analysis":21},881303,"燃气锅炉房的火灾危险性属于( )。",[48,50,52,54],{"key":20,"text":49,"correct":28},"甲类生产厂房",{"key":24,"text":51,"correct":28},"乙类生产厂房",{"key":26,"text":53,"correct":28},"丙类生产厂房",{"key":30,"text":55,"correct":22},"丁类生产厂房",{"id":57,"libraryId":5,"type":34,"typeLabel":35,"stem":21,"options":58,"answer":24,"analysis":21},881304,[59,61,63,65],{"key":20,"text":60,"correct":28},"严重污染区",{"key":24,"text":62,"correct":22},"工业区",{"key":26,"text":64,"correct":28},"城市郊区",{"key":30,"text":66,"correct":28},"清洁区",{"id":68,"libraryId":5,"type":34,"typeLabel":35,"stem":69,"options":70,"answer":30,"analysis":21},881305,"地下、半地下、地下室和半地下室锅炉房严禁选用的气体燃料，其判断的依据是气体燃料的相对密度，该相对密度数值应是下列哪一项？( )",[71,73,75,77],{"key":20,"text":72,"correct":28},"相对密度小于0.60的气体燃料",{"key":24,"text":74,"correct":28},"相对密度大于或等于0.60的气体燃料",{"key":26,"text":76,"correct":28},"相对密度小于0.75的气体燃料",{"key":30,"text":78,"correct":22},"相对密度大于或等于0.75的气体燃料",{"id":80,"libraryId":5,"type":34,"typeLabel":35,"stem":21,"options":81,"answer":24,"analysis":21},881306,[82,84,86,87],{"key":20,"text":83,"correct":28},"按户为单位计算确定",{"key":24,"text":85,"correct":22},"按计算管段分别确定",{"key":26,"text":21,"correct":28},{"key":30,"text":21,"correct":28},{"id":89,"libraryId":5,"type":34,"typeLabel":35,"stem":90,"options":91,"answer":30,"analysis":21},881307,"一民用建筑地下无外窗的人员活动室，其平时通风方案( )是可行的。",[92,94,96,98],{"key":20,"text":93,"correct":28},"利用自然通风",{"key":24,"text":95,"correct":28},"设置机械送风",{"key":26,"text":97,"correct":28},"设置机械排风",{"key":30,"text":99,"correct":22},"设置机械通风并满足人员最小新风量",{"id":101,"libraryId":5,"type":34,"typeLabel":35,"stem":102,"options":103,"answer":24,"analysis":21},881308,"在基准参数要求相同的情况下，空调控制精度要求与空调能耗关系的说法中，正确的是( )。",[104,106,108,110],{"key":20,"text":105,"correct":28},"室温控制精度要求与空调能耗没有关系",{"key":24,"text":107,"correct":22},"空调控制精度要求越高空调能耗越高",{"key":26,"text":109,"correct":28},"空调控制精度要求越高空调能耗越低",{"key":30,"text":111,"correct":28},"不确定",{"id":113,"libraryId":5,"type":34,"typeLabel":35,"stem":114,"options":115,"answer":24,"analysis":21},881309,"沈阳某采暖办公楼的体形系数≤0.3，0.3＜窗墙面积比≤0.4，符合节能要求且节能效果最好的外窗选用，应为下列哪一项？",[116,118,120,122],{"key":20,"text":117,"correct":28},"采用透明中空玻璃塑钢窗，K=2.7",{"key":24,"text":119,"correct":22},"采用透明中空玻璃塑钢窗，K=2.6",{"key":26,"text":121,"correct":28},"采用镀膜中空玻璃塑钢窗K=2.6，外层玻璃的内表面镀Low-E膜",{"key":30,"text":123,"correct":28},"采用镀膜中空玻璃塑钢窗K=2.6，内层玻璃的内表面镀Low-E膜",{"id":125,"libraryId":5,"type":34,"typeLabel":35,"stem":126,"options":127,"answer":20,"analysis":21},881310,"高温制冷剂主要用于( )中。",[128,130,132,134],{"key":20,"text":129,"correct":22},"空气调节用制冷装置和热泵",{"key":24,"text":131,"correct":28},"一般的双级压缩制冷机",{"key":26,"text":133,"correct":28},"复叠式制冷装置的低温级部分",{"key":30,"text":135,"correct":28},"一般的单级压缩制冷机",{"id":137,"libraryId":5,"type":34,"typeLabel":35,"stem":138,"options":139,"answer":30,"analysis":21},881311,"夏季或过渡季随着室外空气湿球温度的降低，冷却水水温已经达到冷水机组的最低供水温度限制时，不应采用下列哪种控制方式？",[140,142,144,146],{"key":20,"text":141,"correct":28},"多台冷却塔的风机台数控制",{"key":24,"text":143,"correct":28},"单台冷却塔风机变速控制",{"key":26,"text":145,"correct":28},"冷却水供回水管之间的旁通电动阀控制",{"key":30,"text":147,"correct":22},"冷却水泵变流量控制",{"id":149,"libraryId":5,"type":34,"typeLabel":35,"stem":150,"options":151,"answer":20,"analysis":21},881312,"在设计输送气体和液体的管道时，为了避免流体流动时产生气囊和液囊，设计原则是( )。",[152,154,156,158],{"key":20,"text":153,"correct":22},"对于输送气体的管道，不允许设计成“∪”形；对于输送液体的管道，不允许设计成“∩”形",{"key":24,"text":155,"correct":28},"对于输送气体的管道，不允许设计成“∩”形，对于输送液体的管道，不允许设计成“∪”形",{"key":26,"text":157,"correct":28},"对于输送气体和液体的管道，均不允许设计成“∩”形",{"key":30,"text":159,"correct":28},"对于输送气体和液体的管道，均不允许设计成“∪”形",{"id":161,"libraryId":5,"type":34,"typeLabel":35,"stem":162,"options":163,"answer":20,"analysis":21},881313,"工业厂房夏季自然通风用的进风口，其下缘距室内地面的高度不应大于下列哪一个数值？( )",[164,166,168,170],{"key":20,"text":165,"correct":22},"1.2m",{"key":24,"text":167,"correct":28},"1.5m",{"key":26,"text":169,"correct":28},"2.0m",{"key":30,"text":171,"correct":28},"2.2m",{"id":173,"libraryId":5,"type":34,"typeLabel":35,"stem":174,"options":175,"answer":24,"analysis":21},881314,"高层民用建筑靠外墙的防烟楼梯间在采用自然排烟时，必须满足的条件是( )。",[176,178,180,182],{"key":20,"text":177,"correct":28},"每5层外窗面积之和不应小于2.00㎡",{"key":24,"text":179,"correct":22},"每5层内可开启外窗总面积之和不应小于2.00㎡",{"key":26,"text":181,"correct":28},"每3层可开启外窗面积之和不应小于2.00㎡",{"key":30,"text":183,"correct":28},"每3层外窗面积之和不应小于2.00㎡",{"id":185,"libraryId":5,"type":34,"typeLabel":35,"stem":186,"options":187,"answer":26,"analysis":21},881315,"下列关于房间空调冷负荷的说法中正确的是( )。",[188,190,192,194],{"key":20,"text":189,"correct":28},"空调冷负荷峰值等于得热量峰值",{"key":24,"text":191,"correct":28},"空调冷负荷峰值一定大于得热量峰值",{"key":26,"text":193,"correct":22},"空调冷负荷峰值一定小于得热量峰值",{"key":30,"text":195,"correct":28},"空调冷负荷峰值可能小于、也可能大于得热量峰值",{"id":197,"libraryId":5,"type":34,"typeLabel":35,"stem":198,"options":199,"answer":20,"analysis":21},881316,"在采用氟利昂制冷剂的制冷系统中，为了防止冰堵，须在( )上设置干燥器。",[200,202,204,206],{"key":20,"text":201,"correct":22},"节流阀前的液体管路",{"key":24,"text":203,"correct":28},"节流阀后的管路",{"key":26,"text":205,"correct":28},"压缩机排气管",{"key":30,"text":207,"correct":28},"压缩机吸气管",{"id":209,"libraryId":5,"type":34,"typeLabel":35,"stem":210,"options":211,"answer":30,"analysis":21},881317,"设置集中采暖的民用建筑物，其室内空气与围护结构内表面之间的允许温差与下列何项无关?( )。",[212,214,216,218],{"key":20,"text":213,"correct":28},"围护结构的最小传热阻",{"key":24,"text":215,"correct":28},"室内空气温度",{"key":26,"text":217,"correct":28},"围护结构内表面换热阻",{"key":30,"text":219,"correct":22},"围护结构外表面换热阻",{"id":221,"libraryId":5,"type":34,"typeLabel":35,"stem":21,"options":222,"answer":30,"analysis":21},881318,[223,224,225,226],{"key":20,"text":21,"correct":28},{"key":24,"text":21,"correct":28},{"key":26,"text":21,"correct":28},{"key":30,"text":21,"correct":22},{"id":228,"libraryId":5,"type":34,"typeLabel":35,"stem":229,"options":230,"answer":26,"analysis":21},881319,"绿色公共建筑外窗可开启面积不小于外窗总面积的( )。",[231,233,235,237],{"key":20,"text":232,"correct":28},"40%",{"key":24,"text":234,"correct":28},"35%",{"key":26,"text":236,"correct":22},"30%",{"key":30,"text":238,"correct":28},"20%",{"id":240,"libraryId":5,"type":34,"typeLabel":35,"stem":241,"options":242,"answer":26,"analysis":21},881320,"一般卫生器具均装设存水弯，它的作用是( )。",[243,245,247,249],{"key":20,"text":244,"correct":28},"美观",{"key":24,"text":246,"correct":28},"产生水封隔声",{"key":26,"text":248,"correct":22},"产生水封防止臭气等进入室内",{"key":30,"text":250,"correct":28},"都不是",{"id":252,"libraryId":5,"type":34,"typeLabel":35,"stem":253,"options":254,"answer":24,"analysis":21},881321,"室内消火栓给水系统中消防管道的水流速( )；自动喷水灭火系统中消防管道的水流速( )。",[255,257,259,261],{"key":20,"text":256,"correct":28},"不宜大于3m\u002Fs，不应大于5m／s",{"key":24,"text":258,"correct":22},"不宜大于2.5m\u002Fs，不应大于5m\u002Fs",{"key":26,"text":260,"correct":28},"不宜大于2.5m／s，不应大于10m\u002Fs",{"key":30,"text":262,"correct":28},"不应大于5m\u002Fs，不应大于10m\u002Fs",{"id":264,"libraryId":5,"type":34,"typeLabel":35,"stem":265,"options":266,"answer":20,"analysis":21},881322,"提高热水网络水力稳定性的主要方法，应选择下列哪一项？( )",[267,269,271,273],{"key":20,"text":268,"correct":22},"网络水力计算时选用较小的比摩阻值，用户水力计算选用较大的比摩阻值",{"key":24,"text":270,"correct":28},"网络水力计算时选用较大的比摩阻值",{"key":26,"text":272,"correct":28},"用户水力计算选用较小的比摩阻值",{"key":30,"text":274,"correct":28},"网络水力计算时选用较大的比摩阻值，用户水力计算选用较小的比摩阻值",{"id":276,"libraryId":5,"type":34,"typeLabel":35,"stem":277,"options":278,"answer":26,"analysis":21},881323,"住宅小区燃气管网的工作压力等级的选择是( )。",[279,281,283,285],{"key":20,"text":280,"correct":28},"中压",{"key":24,"text":282,"correct":28},"低压",{"key":26,"text":284,"correct":22},"中压或低压",{"key":30,"text":286,"correct":28},"次高压、中压或低压",{"id":288,"libraryId":5,"type":34,"typeLabel":35,"stem":289,"options":290,"answer":20,"analysis":21},881324,"在压缩比较大时，滚动转子式压缩机的指示效率比往复活塞式压缩机( )。",[291,293,295,297],{"key":20,"text":292,"correct":22},"高",{"key":24,"text":294,"correct":28},"低",{"key":26,"text":296,"correct":28},"基本一致",{"key":30,"text":298,"correct":28},"不一定",{"id":300,"libraryId":5,"type":34,"typeLabel":35,"stem":301,"options":302,"answer":30,"analysis":21},881325,"在空调系统消声设计时，可以不考虑的噪声源是( )。",[303,305,307,309],{"key":20,"text":304,"correct":28},"室外空调设备的噪声",{"key":24,"text":306,"correct":28},"风口气流噪声",{"key":26,"text":308,"correct":28},"邻室噪声",{"key":30,"text":310,"correct":22},"低速风管的气流噪声",{"id":312,"libraryId":5,"type":34,"typeLabel":35,"stem":313,"options":314,"answer":30,"analysis":21},881326,"冻结物冷藏间，温度为( )℃，相对湿度为( )。",[315,317,319,321],{"key":20,"text":316,"correct":28},"-30～-25，85%～95%",{"key":24,"text":318,"correct":28},"-30～-25，95%～100%",{"key":26,"text":320,"correct":28},"-25～-18，85%～100%",{"key":30,"text":322,"correct":22},"-25～-18，95%～100%",{"id":324,"libraryId":5,"type":34,"typeLabel":35,"stem":325,"options":326,"answer":24,"analysis":21},881327,"具有节能优点的气流组织形式是( )。",[327,329,331,333],{"key":20,"text":328,"correct":28},"下送风",{"key":24,"text":330,"correct":22},"置换通风",{"key":26,"text":332,"correct":28},"上送风",{"key":30,"text":334,"correct":28},"个人空调与背景空调相结合",{"id":336,"libraryId":5,"type":34,"typeLabel":35,"stem":337,"options":338,"answer":20,"analysis":21},881328,"水源热泵机组如采用地下水为水源时，下列哪一项表述是错误的？",[339,341,343,345],{"key":20,"text":340,"correct":22},"采用地下水水源热泵机组必然经济合理",{"key":24,"text":342,"correct":28},"应考虑水资源条件",{"key":26,"text":344,"correct":28},"地下水应采取可靠的回灌措施，回灌水不得对地下水资源造成污染",{"key":30,"text":346,"correct":28},"采用水分散小型单元式机组，应设板式换热器间接换热",{"id":348,"libraryId":5,"type":34,"typeLabel":35,"stem":349,"options":350,"answer":26,"analysis":21},881329,"同时散发余热、余湿和有害气体的工业建筑，除设局部排风外，宜从上部区域进行自然或机械的全面排风，当房间高度小于6m时，其排风量应按( )计算。",[351,352,353,354],{"key":20,"text":21,"correct":28},{"key":24,"text":21,"correct":28},{"key":26,"text":21,"correct":22},{"key":30,"text":21,"correct":28},{"id":356,"libraryId":5,"type":34,"typeLabel":35,"stem":21,"options":357,"answer":26,"analysis":21},881330,[358,360,362,364],{"key":20,"text":359,"correct":28},"若采用常规蒸气压缩制冷循环，压缩机排气无法被环境空气冷凝",{"key":24,"text":361,"correct":28},"采用往复式或斜盘式压缩机",{"key":26,"text":363,"correct":22},"采用跨临界循环，因排气压力过高，循环的性能系数很小",{"key":30,"text":21,"correct":28},{"id":366,"libraryId":5,"type":34,"typeLabel":35,"stem":367,"options":368,"answer":30,"analysis":21},881331,"围护结构防潮验算的目的是( )。",[369,371,373,375],{"key":20,"text":370,"correct":28},"防止围护结构外表面结露",{"key":24,"text":372,"correct":28},"防止围护结构内表面结露",{"key":26,"text":374,"correct":28},"防止围护结构内部结露",{"key":30,"text":376,"correct":22},"防止围护结构中保温材料的湿度增量超过允许值",{"id":378,"libraryId":5,"type":34,"typeLabel":35,"stem":379,"options":380,"answer":30,"analysis":21},881332,"空调水系统定压方式中，正确的是( )。",[381,383,385,387],{"key":20,"text":382,"correct":28},"定压罐不受安装高度的限制，宜优先选用",{"key":24,"text":384,"correct":28},"高位膨胀水箱使空调系统成为开式系统，使系统能耗增加",{"key":26,"text":386,"correct":28},"与定压罐相比，高位膨胀水箱使空调系统工作压力增加",{"key":30,"text":388,"correct":22},"高位膨胀水箱节能、安全可靠、投资低，应优先采用",{"id":390,"libraryId":5,"type":34,"typeLabel":35,"stem":391,"options":392,"answer":26,"analysis":21},881333,"关于防烟分区的设置，( )是错误的。",[393,395,397,399],{"key":20,"text":394,"correct":28},"不设排烟设施的房间(包括地下室)和走道，不划分防烟分区",{"key":24,"text":396,"correct":28},"防烟分区不应跨越防火分区",{"key":26,"text":398,"correct":22},"每个防烟分区的面积，对于高层民用建筑和其他建筑(含地下建筑和人防工程)，其建筑面积不宜大于400㎡",{"key":30,"text":400,"correct":28},"对有特殊用途的场所，如地下室、防烟楼梯间、消防电梯、避难层间等，应单独划分防烟分区",{"id":402,"libraryId":5,"type":34,"typeLabel":35,"stem":403,"options":404,"answer":26,"analysis":21},881334,"建筑屋面雨水管道的设计流态宜采用( )。",[405,407,409,411],{"key":20,"text":406,"correct":28},"均按照重力流设计",{"key":24,"text":408,"correct":28},"均按照压力流设计",{"key":26,"text":410,"correct":22},"汇水面积较小、排水出路较多的宜按照重力流设计；汇水面积较大、排水出路较少的宜按照压力流设计",{"key":30,"text":412,"correct":28},"汇水面积较小、排水出路较多的宜按照压力流设计；汇水面积较大、排水出路较少的宜按照重力流设计",{"id":414,"libraryId":5,"type":34,"typeLabel":35,"stem":415,"options":416,"answer":20,"analysis":21},881335,"焓湿图中与纵坐标轴平行的垂直线为( )。",[417,419,421,423],{"key":20,"text":418,"correct":22},"等含湿量线",{"key":24,"text":420,"correct":28},"等焓线",{"key":26,"text":422,"correct":28},"等温线",{"key":30,"text":424,"correct":28},"等相对湿度线",{"id":426,"libraryId":5,"type":34,"typeLabel":35,"stem":427,"options":428,"answer":20,"analysis":21},881336,"在热水供暖系统中，如果采用铸铁柱型散热器，在其他条件相同的情况下，哪种连接方式的散热量最小？( )",[429,431,433,435],{"key":20,"text":430,"correct":22},"同侧下进上出",{"key":24,"text":432,"correct":28},"异侧下进上出",{"key":26,"text":434,"correct":28},"异侧下进下出",{"key":30,"text":436,"correct":28},"异侧上进上出",{"id":438,"libraryId":5,"type":34,"typeLabel":35,"stem":21,"options":439,"answer":26,"analysis":21},881337,[440,442,444,446],{"key":20,"text":441,"correct":28},"2m=n+p+q+r",{"key":24,"text":443,"correct":28},"2m+1=n+p+q+r",{"key":26,"text":445,"correct":22},"2m+2=n+p+q+r",{"key":30,"text":447,"correct":28},"2m-2=n+p+q+r",{"id":449,"libraryId":5,"type":34,"typeLabel":35,"stem":450,"options":451,"answer":26,"analysis":21},881338,"设置于宾馆、饭店地下室、半地下室的厨房，当使用天然气时，宜设CO浓度检测器，检测器的报警标准数值，应是下列哪一项？( )",[452,454,456,458],{"key":20,"text":453,"correct":28},"0.05%",{"key":24,"text":455,"correct":28},"0.03%",{"key":26,"text":457,"correct":22},"0.02%",{"key":30,"text":459,"correct":28},"0.01%",{"id":461,"libraryId":5,"type":34,"typeLabel":35,"stem":462,"options":463,"answer":26,"analysis":21},881339,"在进行低压蒸汽供暖系统水力计算时，一般为克服散热器阻力预留的剩余压力为( )。",[464,466,468,470],{"key":20,"text":465,"correct":28},"1kPa",{"key":24,"text":467,"correct":28},"1.5kPa",{"key":26,"text":469,"correct":22},"2kPa",{"key":30,"text":471,"correct":28},"2.5kPa",{"id":473,"libraryId":5,"type":34,"typeLabel":35,"stem":474,"options":475,"answer":30,"analysis":21},881340,"压缩式制冷机组膨胀阀的感温包安装位置，何项是正确的?( )。",[476,478,480,482],{"key":20,"text":477,"correct":28},"冷凝器进口的制冷剂管路上",{"key":24,"text":479,"correct":28},"冷凝器出口的制冷剂管路上",{"key":26,"text":481,"correct":28},"蒸发器进口的制冷剂管路上",{"key":30,"text":483,"correct":22},"蒸发器出口的制冷剂管路上",{"id":485,"libraryId":5,"type":34,"typeLabel":35,"stem":486,"options":487,"answer":20,"analysis":21},881341,"夏季空调系统采用全热回收装置对排风进行热回收时，热回收效果最好的情况是下列何项?( )。",[488,490,492,494],{"key":20,"text":489,"correct":22},"室外新风湿球温度比室内空气温度高5℃",{"key":24,"text":491,"correct":28},"室外新风干球温度比排风温度高5℃",{"key":26,"text":493,"correct":28},"室外新风湿球温度比室内空气湿球温度高5℃",{"key":30,"text":495,"correct":28},"室外新风湿球温度比排风湿球温度高5℃",{"id":497,"libraryId":5,"type":34,"typeLabel":35,"stem":498,"options":499,"answer":30,"analysis":21},881342,"住宅建筑采暖系统设计时，下列哪一个计算方法是错误的？",[500,502,504,506],{"key":20,"text":501,"correct":28},"户内采暖设备容量计入向邻室传热引起的耗热量",{"key":24,"text":503,"correct":28},"计算户内管道时，计入向邻室传热引起的耗热量",{"key":26,"text":505,"correct":28},"计算采暖系统总管道时，不计入向邻室传热引起的耗热量",{"key":30,"text":507,"correct":22},"采暖系统总热负荷计入向邻室传热引起的耗热量",{"id":509,"libraryId":5,"type":34,"typeLabel":35,"stem":510,"options":511,"answer":30,"analysis":21},881343,"按规范要求，采暖、通风和空气调节系统在一定条件下应采用防爆型设备。下列哪一项叙述是错误的？",[512,514,516,518],{"key":20,"text":513,"correct":28},"直接布置在有甲、乙类物质场所中的通风、空气调节和热风采暖设备",{"key":24,"text":515,"correct":28},"排除有甲类物质的通风设备",{"key":26,"text":517,"correct":28},"排除有乙类物质的通风设备",{"key":30,"text":519,"correct":22},"排除含有燃烧或爆炸危险的粉尘、纤维等丙类物质，其含尘浓度高于或等于其爆炸下限的50%时的设备",{"id":521,"libraryId":5,"type":34,"typeLabel":35,"stem":522,"options":523,"answer":26,"analysis":21},881344,"关于空调建筑的新风问题，下列说法中正确的是( )。",[524,526,528,530],{"key":20,"text":525,"correct":28},"设置新风系统比开窗通风方式更节能",{"key":24,"text":527,"correct":28},"设置新风系统比开窗通风的通风效果更好",{"key":26,"text":529,"correct":22},"目前的开窗通风方式无法对通风量进行有效控制",{"key":30,"text":531,"correct":28},"空调新风系统运行时应禁止开窗",{"id":533,"libraryId":5,"type":34,"typeLabel":35,"stem":534,"options":535,"answer":30,"analysis":21},881345,"热水散热器供暖上供下回双管立管，其他条件不变，如果相同缩小各层连接散热器支管段的管径，对各层散热器流量的影响是( )。",[536,538,540,542],{"key":20,"text":537,"correct":28},"各层散热器的流量等比增大",{"key":24,"text":539,"correct":28},"各层散热器的流量等比减小",{"key":26,"text":541,"correct":28},"上层散热器的流量变化比例小于下层",{"key":30,"text":543,"correct":22},"上层散热器的流量变化比例大于下层",{"id":545,"libraryId":5,"type":34,"typeLabel":35,"stem":546,"options":547,"answer":26,"analysis":21},881346,"我国已建成的冰蓄冷工程最常用的双工况制冷机是下列哪一项？( )",[548,550,552,554],{"key":20,"text":549,"correct":28},"活塞式",{"key":24,"text":551,"correct":28},"涡旋式",{"key":26,"text":553,"correct":22},"螺杆式",{"key":30,"text":555,"correct":28},"离心式",{"id":557,"libraryId":5,"type":34,"typeLabel":35,"stem":558,"options":559,"answer":26,"analysis":21},881347,"在建筑空调节能诊断时，能否根据一周的能耗测试数据对整个空调季的空调总能耗进行比较准确地预测和评判？( )",[560,562,564,566],{"key":20,"text":561,"correct":28},"可以",{"key":24,"text":563,"correct":28},"有经验的专家可以",{"key":26,"text":565,"correct":22},"不能",{"key":30,"text":111,"correct":28},{"id":568,"libraryId":5,"type":34,"typeLabel":35,"stem":569,"options":570,"answer":24,"analysis":21},881348,"为防止可燃粉尘、纤维与供暖散热器接触引起自燃，应控制热媒温度，下列哪一项是正确的？( )",[571,573,575,577],{"key":20,"text":572,"correct":28},"0.2MPa蒸汽",{"key":24,"text":574,"correct":22},"供回水温度95℃\u002F70℃",{"key":26,"text":576,"correct":28},"0.3MPa蒸汽",{"key":30,"text":578,"correct":28},"供回水温度130℃\u002F70℃",{"id":580,"libraryId":5,"type":34,"typeLabel":35,"stem":581,"options":582,"answer":26,"analysis":21},881349,"下述四种关于“大气污染物最高允许浓度”的叙述，哪一项不符合《大气污染物综合排放标准》GB162971996的规定？",[583,585,587,589],{"key":20,"text":584,"correct":28},"指无处理设施后，排气筒污染物任何一小时浓度平均值不得超过的限值",{"key":24,"text":586,"correct":28},"指无处理设施后，排气筒污染物任何一小时浓度平均值不得超过的最大值",{"key":26,"text":588,"correct":22},"指处理设施后，排气筒污染物任何时刻浓度不得超过的限值",{"key":30,"text":590,"correct":28},"指处理设施后，排气筒污染物任何一小时浓度平均值不得超过的限值",{"id":592,"libraryId":5,"type":34,"typeLabel":35,"stem":593,"options":594,"answer":24,"analysis":21},881350,"同一室外气候条件，有关空气源热泵机组的说法下列哪项是错误的？",[595,597,599,601],{"key":20,"text":596,"correct":28},"冬季供水温度低的机组比供水温度高的机组能效比更高",{"key":24,"text":598,"correct":22},"冬季供水温度相同，供回水温差大的机组比供回水温差小的机组能效比更高",{"key":26,"text":600,"correct":28},"供应卫生热水的空气源热泵热水机夏季的供热量要大于冬季的供热量",{"key":30,"text":602,"correct":28},"向厂家订购热泵机组时，应明确项目所在地的气候条件",[604,607,610,613,616,619],{"id":34,"name":605,"category":7,"favorite":606},"领导干部任职前廉政法规知识测试题",92,{"id":608,"name":609,"category":7,"favorite":34},595,"建筑结构与设备",{"id":611,"name":612,"category":7,"favorite":34},715,"招标采购专业知识与法律法规",{"id":614,"name":615,"category":7,"favorite":34},848,"市政方向-通用基础",{"id":617,"name":618,"category":7,"favorite":8},534,"BIM工程师",{"id":620,"name":618,"category":7,"favorite":8},535]