[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-3":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":623},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,3,50,2054,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,313,326,339,351,360,373,386,398,411,423,436,449,461,473,485,494,506,519,530,542,551,563,575,587,599,611],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},879951,1,"单选题","某局部排风系统，排除一种易爆气体，其排风量应按风管内该气体的浓度不大于爆炸浓度下限的一个百分比进行计算，则该百分比应是下列哪一项？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","50%",true,{"key":24,"text":25,"correct":26},"B","55%",false,{"key":28,"text":29,"correct":26},"C","60%",{"key":31,"text":32,"correct":26},"D","65%","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},879952,"与单级蒸气压缩制冷循环相比，关于带节能器的多级蒸气压缩制冷循环的描述中，下列哪一项是错误的？",[38,40,42,44],{"key":20,"text":39,"correct":26},"节流损失减小",{"key":24,"text":41,"correct":26},"过热损失减小",{"key":28,"text":43,"correct":22},"排气温度升高",{"key":31,"text":45,"correct":26},"制冷系数提高",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},879953,"仅选用单台冷水机组且连续运行的建筑物空调系统，应优先选用哪类机组？( )",[50,52,54,56],{"key":20,"text":51,"correct":26},"能效比(EER)低的机组",{"key":24,"text":53,"correct":26},"额定工况和高负荷下EER高的机组",{"key":28,"text":55,"correct":26},"综合部分负荷性能系数(IPLV)低的机组",{"key":31,"text":57,"correct":22},"IPLV高的机组",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},879954,"关于围护结构基本耗热量，下列哪种说法是正确的？( )",[62,64,66,68],{"key":20,"text":63,"correct":22},"包含了计算温差修正",{"key":24,"text":65,"correct":26},"包含了墙体热惰性修正",{"key":28,"text":67,"correct":26},"包含了日照附加修正",{"key":31,"text":69,"correct":26},"包含了高度附加修正",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},879955,"自然通风的特点是( )。",[74,76,78,80],{"key":20,"text":75,"correct":22},"依靠风压、热压，不使用机械动力",{"key":24,"text":77,"correct":26},"依靠建筑物天窗",{"key":28,"text":79,"correct":26},"没有气流组织",{"key":31,"text":81,"correct":26},"没有风机、风管",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},879956,"热网中继泵吸入口的压力不应低于下列哪个值？( )",[86,88,90,92],{"key":20,"text":87,"correct":26},"吸入口可能达到的最高水温下的饱和蒸汽压力加30kPa",{"key":24,"text":89,"correct":22},"吸入口可能达到的最高水温下的饱和蒸汽压力加50kPa",{"key":28,"text":91,"correct":26},"30kPa",{"key":31,"text":93,"correct":26},"50kPa",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},879957,"下列关于电动压缩式冷水机组的冷却水进口温度的要求中，正确的是( )。",[98,100,102,104],{"key":20,"text":99,"correct":26},"越低越好",{"key":24,"text":101,"correct":26},"不宜低于7℃",{"key":28,"text":103,"correct":26},"不宜低于12℃",{"key":31,"text":105,"correct":22},"不宜低于15.5℃",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":28,"analysis":33},879958,"低温辐射供暖的界定范围是( )。",[110,112,114,116],{"key":20,"text":111,"correct":26},"板面温度低于28℃",{"key":24,"text":113,"correct":26},"板面温度低于32℃",{"key":28,"text":115,"correct":22},"板面温度低于80℃",{"key":31,"text":117,"correct":26},"限于低温热水地面辐射供暖",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},879959,"按照《民用暖规》，Ⅱ级热舒适度空调房间的PPD值宜小于等于( )。",[122,124,126,128],{"key":20,"text":123,"correct":26},"10%",{"key":24,"text":125,"correct":26},"15%",{"key":28,"text":127,"correct":26},"20%",{"key":31,"text":129,"correct":22},"27%",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},879960,"冷热电三联供系统中，补燃制冷机的制冷量以总制冷量的( )为宜。",[134,136,138,140],{"key":20,"text":135,"correct":26},"20%～40%",{"key":24,"text":137,"correct":26},"25%～45%",{"key":28,"text":139,"correct":22},"30%～50%",{"key":31,"text":141,"correct":26},"35%～55%",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},879961,"热力站热表的流量传感器应安装在下列哪个位置？( )",[146,148,150,152],{"key":20,"text":147,"correct":22},"一次管网回水管上",{"key":24,"text":149,"correct":26},"一次管网供水管上",{"key":28,"text":151,"correct":26},"二次管网回水管上",{"key":31,"text":153,"correct":26},"二次管网供水管上",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":20,"analysis":33},879962,"热泵式空调机用于制热时，其制热系数( )工况条件完全相同时制冷运行的制冷性能系数。",[158,160,162,164],{"key":20,"text":159,"correct":22},"大于",{"key":24,"text":161,"correct":26},"小于",{"key":28,"text":163,"correct":26},"等于",{"key":31,"text":165,"correct":26},"不可比",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},879963,"关于组合空调机组的检查周期规定中正确的是( )。",[170,172,174,176],{"key":20,"text":171,"correct":26},"每半年不少于1次",{"key":24,"text":173,"correct":22},"每年不少于1次",{"key":28,"text":175,"correct":26},"每2年不少于1次",{"key":31,"text":177,"correct":26},"每3年不少于1次",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":24,"analysis":33},879964,"某空调系统在调试时，发生离心式风机电动机的电流超值，试问是下列哪一种原因引起的？( )",[182,184,186,188],{"key":20,"text":183,"correct":26},"空气过滤器阻塞、阻力增大，致使所需电动机功率增大",{"key":24,"text":185,"correct":22},"系统阻力小于设计值，致使风量增大",{"key":28,"text":187,"correct":26},"空调区出口风阀未开启，致使风机压力上升，电流增大",{"key":31,"text":189,"correct":26},"风机的风压偏小，导致风量增加",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":28,"analysis":33},879965,"燃气引入管正确的设计，应为下列哪一项？",[194,196,198,200],{"key":20,"text":195,"correct":26},"燃气引入管穿越住宅的暖气沟",{"key":24,"text":197,"correct":26},"燃气引入管从建筑物的楼梯间引入",{"key":28,"text":199,"correct":22},"穿墙管与其中的燃气管之间的间隙采用柔性防腐、防水材料填实",{"key":31,"text":201,"correct":26},"燃气引入管均采取防止变形的补偿措施",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":31,"analysis":33},879966,"对于有害气体的处理，常用的处理方法中( )是不提倡采用的。",[206,208,210,212],{"key":20,"text":207,"correct":26},"燃烧法",{"key":24,"text":209,"correct":26},"吸附法",{"key":28,"text":211,"correct":26},"吸收法",{"key":31,"text":213,"correct":22},"高空稀释法",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":24,"analysis":33},879967,"关于空调系统采用热回收装置做法和说法，下列哪项是不恰当的?( )。",[218,220,222,224],{"key":20,"text":219,"correct":26},"五星级酒店的室内游泳池夏季采用转轮式全热热回收装置",{"key":24,"text":221,"correct":22},"办公建筑的会议室选用双向换气热回收装置",{"key":28,"text":223,"correct":26},"设计状态下送、排风的温度差和过渡季节时间长短成为选择热回收装置的依据",{"key":31,"text":225,"correct":26},"热回收装置节能与否，应综合考虑回收的能量和回收装置自身的设备用能",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":20,"analysis":33},879968,"采用变温降法热水供暖系统水力计算是依据下列哪个原理？( )",[230,232,234,236],{"key":20,"text":231,"correct":22},"水力等比一致失调",{"key":24,"text":233,"correct":26},"水力不一致失调",{"key":28,"text":235,"correct":26},"热力等比一致失调",{"key":31,"text":237,"correct":26},"热力不一致失调",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":28,"analysis":33},879969,"关于变制冷剂流量(VR F)空调系统的特点，下列表述中正确的是( )。",[242,244,246,248],{"key":20,"text":243,"correct":26},"热泵式VRF机组可以在-15℃的低温环境中工作，因此热泵式VRF空调系统适合于严寒地区的建筑供暖",{"key":24,"text":245,"correct":26},"随着VRF技术的发展，接管距离可以越来越长，因此其系统规模可以做大，以发挥规模效益",{"key":28,"text":247,"correct":22},"在VRF空调系统制冷量计算时，当制冷连接管较长时应进行修正",{"key":31,"text":249,"correct":26},"VRF空调系统的室内机连接率可以达到130%，因此它是节能的",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":31,"analysis":33},879970,"当需要将多根立管的通气管汇合连接时，其汇合通气管的管径确定原则应为( )。",[254,256,258,260],{"key":20,"text":255,"correct":26},"比最大一根通气管的管径大一号",{"key":24,"text":257,"correct":26},"断面积为所有通气管的断面积之和",{"key":28,"text":259,"correct":26},"最大一根通气管的断面积加其余通气管断面积之和的0.5倍",{"key":31,"text":261,"correct":22},"最大一根通气管的断面积加其余通气管断面积之和的0.25倍",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":24,"analysis":33},879971,"额定制冷量为40kW的风冷式冷水机组，根据下列条件可以判断哪一个是节能产品？( )",[266,268,270,272],{"key":20,"text":267,"correct":26},"实测能效比为3.1",{"key":24,"text":269,"correct":22},"额定能效比为3.1",{"key":28,"text":271,"correct":26},"实测能效比为3.2",{"key":31,"text":273,"correct":26},"额定能效比为2.9",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":24,"analysis":33},879972,"对既有采暖居住建筑供热系统节能改造的技术措施中，下列哪一项技术措施是实行其他技术的前提？",[278,280,282,284],{"key":20,"text":279,"correct":26},"在热力站安装气候补偿器",{"key":24,"text":281,"correct":22},"在热网实现水力平衡",{"key":28,"text":283,"correct":26},"在室内安装温控装置",{"key":31,"text":285,"correct":26},"对用户安装分户热计量装置",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":28,"analysis":33},879973,"关于空气处理过程的说法中正确的是( )。",[290,292,294,296],{"key":20,"text":291,"correct":26},"空气处理过程在焓湿图上一定是一条连接初始状态和终止状态的直线",{"key":24,"text":293,"correct":26},"由于水在低于0℃的环境下会结冰，因此湿球温度不可能低于0℃",{"key":28,"text":295,"correct":22},"溶液除湿系统冬季可以实现加热加湿",{"key":31,"text":297,"correct":26},"由于喷雾加湿不需要负担水的汽化潜热，因此它比蒸汽加湿更为节能",{"id":299,"libraryId":5,"type":300,"typeLabel":301,"stem":302,"options":303,"answer":312,"analysis":33},879974,2,"多选题","关于在有爆炸危险场合布置通风空调设备的规定，下列哪几项是正确的？( )",[304,306,308,310],{"key":20,"text":305,"correct":22},"用于甲、乙类场所的送风设备，不应与排风设备布置在同一通风机房内",{"key":24,"text":307,"correct":22},"空气中含有铝粉的房间应采用防爆型分体空调器",{"key":28,"text":309,"correct":26},"布置在有甲、乙、丙类物质场所中的通风设备应采用防爆型设备",{"key":31,"text":311,"correct":22},"净化有爆炸危险粉尘的干式除尘器，应布置在系统的负压段上","ABD",{"id":314,"libraryId":5,"type":300,"typeLabel":301,"stem":315,"options":316,"answer":325,"analysis":33},879975,"在确定车间热负荷时，下列( )计入散热量的原则是合理的。",[317,319,321,323],{"key":20,"text":318,"correct":26},"冬季经常而不稳定的散热量采用最小值",{"key":24,"text":320,"correct":22},"夏季经常而不稳定的散热量采用最大值",{"key":28,"text":322,"correct":22},"冬季不经常的散热量可以不计",{"key":31,"text":324,"correct":26},"夏季不经常的散热量必须考虑","BC",{"id":327,"libraryId":5,"type":300,"typeLabel":301,"stem":328,"options":329,"answer":338,"analysis":33},879976,"关于压缩机，正确的是( )。",[330,332,334,336],{"key":20,"text":331,"correct":26},"涡旋压缩机和滚动转子压缩机均没有吸气和排气阀",{"key":24,"text":333,"correct":22},"相同压缩比下，涡旋压缩机的容积效率高于滚动转子压缩机",{"key":28,"text":335,"correct":26},"单螺杆压缩机的转子旋转一周，每个基元容积压缩一次",{"key":31,"text":337,"correct":22},"对涡旋压缩机和螺杆压缩机均可进行喷液冷却","BD",{"id":340,"libraryId":5,"type":300,"typeLabel":301,"stem":341,"options":342,"answer":325,"analysis":33},879977,"通风机输送空气密度发生变化后的性能变化(其他条件不变)，( )是错误的。",[343,345,347,349],{"key":20,"text":344,"correct":26},"风机风量不变",{"key":24,"text":346,"correct":22},"风机风压不变",{"key":28,"text":348,"correct":22},"风机功率不变",{"key":31,"text":350,"correct":26},"风机全压效率不变",{"id":352,"libraryId":5,"type":300,"typeLabel":301,"stem":33,"options":353,"answer":359,"analysis":33},879978,[354,355,357,358],{"key":20,"text":33,"correct":26},{"key":24,"text":356,"correct":22},"应按压缩机的形式不同分别对待",{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},"BCD",{"id":361,"libraryId":5,"type":300,"typeLabel":301,"stem":362,"options":363,"answer":372,"analysis":33},879979,"根据我国空气过滤器标准，中效空气过滤器效率测试中不采用的粒径是( )。",[364,366,368,370],{"key":20,"text":365,"correct":22},"粒径≥10μm",{"key":24,"text":367,"correct":22},"10μm＞粒径≥5μm",{"key":28,"text":369,"correct":22},"5μm＞粒径≥2μm",{"key":31,"text":371,"correct":26},"2μm＞粒径≥0.5μm","ABC",{"id":374,"libraryId":5,"type":300,"typeLabel":301,"stem":375,"options":376,"answer":385,"analysis":33},879980,"建筑高度为70m的高层塔式住宅，其剪刀楼梯间每层各有可开启外窗面积1.5㎡，但需要共用与消防电梯合用的前室，下列哪些防排烟设计做法是错误的？( )",[377,379,381,383],{"key":20,"text":378,"correct":22},"如果合用前室也具有自然排烟条件，楼梯间和合用前室都可以采用自然排烟",{"key":24,"text":380,"correct":26},"如果合用前室不具有自然排烟条件，对前室和两个楼梯间分别设置加压送风系统",{"key":28,"text":382,"correct":22},"如果合用前室不具有自然排烟条件，仅对两个楼梯间分别设置机械加压送风系统",{"key":31,"text":384,"correct":22},"如果合用前室不具有自然排烟条件，仅对前室加压送风","ACD",{"id":387,"libraryId":5,"type":300,"typeLabel":301,"stem":388,"options":389,"answer":312,"analysis":33},879981,"为减轻垂直双管热水供暖系统的垂直失调，正确的做法应是( )。",[390,392,394,396],{"key":20,"text":391,"correct":22},"采取下供下回式系统",{"key":24,"text":393,"correct":22},"散热器温控阀采用高阻阀",{"key":28,"text":395,"correct":26},"增大供暖管道-的直径，减小阻力损失",{"key":31,"text":397,"correct":22},"水力计算时考虑重力循环作用压力的影响",{"id":399,"libraryId":5,"type":300,"typeLabel":301,"stem":400,"options":401,"answer":410,"analysis":33},879982,"在R134a制冷系统中应当严格限制存在或使用的物质是( )。",[402,404,406,408],{"key":20,"text":403,"correct":22},"水分",{"key":24,"text":405,"correct":22},"矿物油",{"key":28,"text":407,"correct":26},"铝",{"key":31,"text":409,"correct":26},"铜","AB",{"id":412,"libraryId":5,"type":300,"typeLabel":301,"stem":413,"options":414,"answer":359,"analysis":33},879983,"下列关于热湿负荷的说法，哪几项是错误的?( )。",[415,417,419,421],{"key":20,"text":416,"correct":26},"某商业建筑的空调设计负荷可以小于实际运行中出现的最大负荷",{"key":24,"text":418,"correct":22},"某建筑冬季有分别需要供冷和供热的两个房间，应按两个房间净热抵消后的冷热量来选择冷热源",{"key":28,"text":420,"correct":22},"对于夏季需要湿度控制的工艺类空调，采用冷凝除湿后的空气与未处理前的空气进行热交换，可以显著减少再热量，但不会影响选择冷机的制冷量",{"key":31,"text":422,"correct":22},"对于室内仅有温度要求而无湿度要求的风机盘管加新风系统，空调系统的设计负荷可仅考虑显热负荷",{"id":424,"libraryId":5,"type":300,"typeLabel":301,"stem":425,"options":426,"answer":435,"analysis":33},879984,"生活热水系统中，设置排气设施的部位有( )。",[427,429,431,433],{"key":20,"text":428,"correct":22},"上行下给式系统的配水干管最高处应设自动排气阀",{"key":24,"text":430,"correct":22},"下行上给式系统无分户计量表时，可利用最高配水点放气",{"key":28,"text":432,"correct":22},"下行上给式系统当入户支管上有分户计量表时，应在各供水立管顶设自动排气阀",{"key":31,"text":434,"correct":22},"向上抬高的管段应设自动排气阀","ABCD",{"id":437,"libraryId":5,"type":300,"typeLabel":301,"stem":438,"options":439,"answer":448,"analysis":33},879985,"下列制冷剂中具有“滑移温度”的是( )。",[440,442,444,446],{"key":20,"text":441,"correct":26},"R717",{"key":24,"text":443,"correct":26},"R502",{"key":28,"text":445,"correct":22},"R407C",{"key":31,"text":447,"correct":22},"R410A","CD",{"id":450,"libraryId":5,"type":300,"typeLabel":301,"stem":451,"options":452,"answer":448,"analysis":33},879986,"下列关于空调冷水机组的冷却水泵变频调节的说法中，不正确的是( )。",[453,455,457,459],{"key":20,"text":454,"correct":26},"一定使冷却水泵能耗减少",{"key":24,"text":456,"correct":26},"一定使冷却水系统能耗减少",{"key":28,"text":458,"correct":22},"可能使冷水机组能耗减少",{"key":31,"text":460,"correct":22},"一定使空调系统总能耗减少",{"id":462,"libraryId":5,"type":300,"typeLabel":301,"stem":463,"options":464,"answer":385,"analysis":33},879987,"使用燃气型冷热电三联供系统，下列哪些是应具备的联供负荷条件？( )",[465,467,469,471],{"key":20,"text":466,"correct":22},"燃气轮发电机的总容量小于或等于15MW",{"key":24,"text":468,"correct":26},"供冷、热负荷不小于燃气轮发电机的总容量",{"key":28,"text":470,"correct":22},"联供系统年运行时间不应小于3500h",{"key":31,"text":472,"correct":22},"用户全年有冷热负荷需求，且电力负荷与冷热负荷使用规律相似",{"id":474,"libraryId":5,"type":300,"typeLabel":301,"stem":475,"options":476,"answer":385,"analysis":33},879988,"下列关于风机盘管性能的表述，错误的是( )。",[477,479,481,483],{"key":20,"text":478,"correct":22},"由于风机盘管干工况运行时没有冷凝潜热损失，因此供冷量较大",{"key":24,"text":480,"correct":26},"冷水平均温度相同，供回水温差越大风机盘管的制冷量越小",{"key":28,"text":482,"correct":22},"采用供水阀调节风机盘管的供冷量，可以大幅度减小水系统流量，使循环水泵的能耗大幅度减小",{"key":31,"text":484,"correct":22},"风机盘管的冷量应按高档选取，以减少风机盘管的投资",{"id":486,"libraryId":5,"type":300,"typeLabel":301,"stem":487,"options":488,"answer":325,"analysis":33},879989,"下列关于实际制冷循环中传热温差对制冷系数的影响叙述正确的是( )。",[489,490,491,493],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":22},{"key":28,"text":492,"correct":22},"有传热温差时制冷系数总小于逆卡诺循环的制冷系数",{"key":31,"text":33,"correct":26},{"id":495,"libraryId":5,"type":300,"typeLabel":301,"stem":496,"options":497,"answer":448,"analysis":33},879990,"选择锅炉房燃料时，下列哪些做法是正确的？( )",[498,500,502,504],{"key":20,"text":499,"correct":26},"设在其他建筑物内的锅炉房应选用燃煤或燃油锅炉",{"key":24,"text":501,"correct":26},"燃油锅炉宜选用重油或渣油作燃料",{"key":28,"text":503,"correct":22},"地下锅炉房燃料严禁选用液化石油气",{"key":31,"text":505,"correct":22},"半地下室锅炉房严禁选用相对密度大于或等于0.75的气体燃料",{"id":507,"libraryId":5,"type":300,"typeLabel":301,"stem":508,"options":509,"answer":518,"analysis":33},879991,"关于蓄冷系统的说法，下列选项中正确的是哪几项？( )",[510,512,514,516],{"key":20,"text":511,"correct":22},"冰蓄冷系统通常能够节约运行费用但不能减少能耗",{"key":24,"text":513,"correct":26},"蓄冷系统不适合有夜间负荷的建筑",{"key":28,"text":515,"correct":22},"水蓄冷系统的投资回收期通常比冰蓄冷系统短",{"key":31,"text":517,"correct":26},"冰蓄冷系统采用制冷机优先策略可最大幅度节约运行费用","AC",{"id":520,"libraryId":5,"type":300,"typeLabel":301,"stem":33,"options":521,"answer":518,"analysis":33},879992,[522,524,526,528],{"key":20,"text":523,"correct":22},"将热水泵出口的手动阀门开度关小",{"key":24,"text":525,"correct":26},"检修供回水管的压差旁通控制环节",{"key":28,"text":527,"correct":22},"将原来的热水泵变更为小扬程的水泵",{"key":31,"text":529,"correct":26},"加大热交换器的面积",{"id":531,"libraryId":5,"type":300,"typeLabel":301,"stem":532,"options":533,"answer":372,"analysis":33},879993,"下列关于压力不大于1.6MPa的室外燃气管道，正确的设计是( )。",[534,536,538,540],{"key":20,"text":535,"correct":22},"地下燃气管道不得从建筑物和大型的构筑物的下面穿越",{"key":24,"text":537,"correct":22},"地下燃气管线穿越主要道路下时，应加套管",{"key":28,"text":539,"correct":22},"燃气管道随桥梁敷设或采用管桥跨越河流时，应设置必要的补偿和减振措施",{"key":31,"text":541,"correct":26},"燃气管穿越或跨越重要河流时，可只在河流两岸中来气的一段设置阀门",{"id":543,"libraryId":5,"type":300,"typeLabel":301,"stem":544,"options":545,"answer":372,"analysis":33},879994,"以干压缩替代湿压缩后，产生的过热损失主要与( )有关。",[546,547,548,550],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":28,"text":549,"correct":22},"制冷剂物性",{"key":31,"text":33,"correct":26},{"id":552,"libraryId":5,"type":300,"typeLabel":301,"stem":553,"options":554,"answer":448,"analysis":33},879995,"关于冷却设备的选型计算，下列说法正确的是( )。",[555,557,559,561],{"key":20,"text":556,"correct":26},"对于包装间，当室温低于-5℃时，宜选用冷风机；室温高于-5℃时，宜选用冷风机采用墙排管",{"key":24,"text":558,"correct":26},"冻结物冷藏间必须采用墙排管、顶排管等冷却设备",{"key":28,"text":560,"correct":22},"贮冰间采用分散均匀满布的方式设置顶排管",{"key":31,"text":562,"correct":22},"冷却间、冻结间和冷却物冷藏间的冷却设备采用冷风机",{"id":564,"libraryId":5,"type":300,"typeLabel":301,"stem":565,"options":566,"answer":312,"analysis":33},879996,"采暖系统干管安装坡度为o.003时的应用范围，是下列哪几项？",[567,569,571,573],{"key":20,"text":568,"correct":22},"供、回水管道",{"key":24,"text":570,"correct":22},"汽、水同向流动管道",{"key":28,"text":572,"correct":26},"汽、水逆向流动管道",{"key":31,"text":574,"correct":22},"凝结水管道",{"id":576,"libraryId":5,"type":300,"typeLabel":301,"stem":577,"options":578,"answer":435,"analysis":33},879997,"低温热水地面辐射供暖系统，包括下列哪些形式？( )",[579,581,583,585],{"key":20,"text":580,"correct":22},"直接供暖系统",{"key":24,"text":582,"correct":22},"间接供暖系统",{"key":28,"text":584,"correct":22},"采用三通阀的混水系统",{"key":31,"text":586,"correct":22},"采用两通阀的混水系统",{"id":588,"libraryId":5,"type":300,"typeLabel":301,"stem":589,"options":590,"answer":338,"analysis":33},879998,"在计算围护结构传热量时，室外或邻室计算温度叙述错误的是( )。",[591,593,595,597],{"key":20,"text":592,"correct":26},"对于外墙，采用夏季空调室外逐时计算综合温度",{"key":24,"text":594,"correct":22},"对于屋顶，采用夏季空调室外逐时计算温度",{"key":28,"text":596,"correct":26},"对于内墙，采用邻室计算平均温度",{"key":31,"text":598,"correct":22},"对于外窗，采用夏季空调室外逐时计算综合温度",{"id":600,"libraryId":5,"type":300,"typeLabel":301,"stem":601,"options":602,"answer":385,"analysis":33},879999,"选择采暖散热器时，应符合( )的规定。",[603,605,607,609],{"key":20,"text":604,"correct":22},"散热器的工作压力应满足系统的工作压力，并应符合国家现行有关产品标准",{"key":24,"text":606,"correct":26},"蒸汽采暖系统不应采用铸铁散热器",{"key":28,"text":608,"correct":22},"采用钢制散热器时，应采用闭式系统",{"key":31,"text":610,"correct":22},"相对湿度较大的房间应采用耐腐蚀的散热器",{"id":612,"libraryId":5,"type":300,"typeLabel":301,"stem":613,"options":614,"answer":338,"analysis":33},880000,"有关室内消防用水量的说法，正确的应是下列哪几项？",[615,617,619,621],{"key":20,"text":616,"correct":26},"建筑物内同时设置多种消防系统，且需要同时开启时，室内消火栓的用水量可以下降，但不得小于10L\u002Fs",{"key":24,"text":618,"correct":22},"高度为12m的厂房按建筑物体积的不同区分有不同的室内消火栓的最小用量",{"key":28,"text":620,"correct":26},"25m高的库房按建筑体积的不同区分有不同的室内消火栓的最小用水量",{"key":31,"text":622,"correct":22},"两层的经济型旅馆的室内消火栓的最小用水量仅与建筑物体积有关",[624,627,630,633,636,639],{"id":15,"name":625,"category":7,"favorite":626},"领导干部任职前廉政法规知识测试题",92,{"id":628,"name":629,"category":7,"favorite":15},595,"建筑结构与设备",{"id":631,"name":632,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":634,"name":635,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":637,"name":638,"category":7,"favorite":8},534,"BIM工程师",{"id":640,"name":638,"category":7,"favorite":8},535]