[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-29":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":620},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,29,50,2054,[13,32,45,57,70,84,96,109,122,135,147,158,166,178,190,202,214,226,238,251,263,275,288,300,312,324,334,342,354,366,379,391,403,415,427,439,451,463,475,487,499,511,523,535,547,559,572,584,596,608],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":31,"analysis":21},881251,2,"多选题","下列空调矩形风管在相应工作压力下的漏风量测试结果中，不符合要求的是( )。",[19,23,26,28],{"key":20,"text":21,"correct":22},"A","",false,{"key":24,"text":21,"correct":25},"B",true,{"key":27,"text":21,"correct":25},"C",{"key":29,"text":30,"correct":25},"D","漏风量为送风量的2%","BCD",{"id":33,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":35,"answer":44,"analysis":21},881252,"采用自然通风的车间，其天窗所起的作用，下列哪几项是错误的？( )",[36,38,40,42],{"key":20,"text":37,"correct":25},"总是起排风作用",{"key":24,"text":39,"correct":22},"在多跨车间可能用来进风",{"key":27,"text":41,"correct":25},"避风天窗处于迎风状态时宜自动关闭，防止倒灌",{"key":29,"text":43,"correct":22},"避风天窗不受风向影响，自然通风计算时只考虑热压","AC",{"id":46,"libraryId":5,"type":15,"typeLabel":16,"stem":47,"options":48,"answer":31,"analysis":21},881253,"绿色居住建筑应包含哪些内容？( )",[49,51,53,55],{"key":20,"text":50,"correct":22},"人均居住用地指标不高于50㎡",{"key":24,"text":52,"correct":25},"保护环境和减少污染的建筑",{"key":27,"text":54,"correct":25},"健康的建筑",{"key":29,"text":56,"correct":25},"最大限度节约资源(节能、节地、节水、节材)的建筑",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":69,"analysis":21},881254,"冷库围护结构设置防潮隔汽构造的目的是( )。",[61,63,65,67],{"key":20,"text":62,"correct":25},"防止蒸汽进入隔热材料影响隔热效果",{"key":24,"text":64,"correct":25},"避免冷库围护结构遭受破坏",{"key":27,"text":66,"correct":22},"防止水蒸气进入冷间使食品受潮",{"key":29,"text":68,"correct":25},"提高围护结构的隔热性","ABD",{"id":71,"libraryId":5,"type":72,"typeLabel":73,"stem":74,"options":75,"answer":27,"analysis":21},881255,1,"单选题","关于锅炉房的工艺布置，下列哪一项是正确的？( )",[76,78,80,82],{"key":20,"text":77,"correct":22},"鼓风机和引风机之间的距离为0.5m",{"key":24,"text":79,"correct":22},"操作平台的宽度为0.6m",{"key":27,"text":81,"correct":25},"循环水泵基础之间的净距离为0.7m",{"key":29,"text":83,"correct":22},"平台和扶梯不必配置栏杆",{"id":85,"libraryId":5,"type":72,"typeLabel":73,"stem":86,"options":87,"answer":29,"analysis":21},881256,"某热水采暖系统的采暖管道施工说明，下列哪一项是错误的？",[88,90,92,94],{"key":20,"text":89,"correct":22},"气、水在水平管道内逆向流动时，管道坡度是5%",{"key":24,"text":91,"correct":22},"气、水在水平管道内同向流动时，管道坡度是3%",{"key":27,"text":93,"correct":22},"连接散热器的支管管道坡度是1%",{"key":29,"text":95,"correct":25},"公称管径为80mm的镀锌钢管应采用焊接",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":108,"analysis":21},881257,"按结构分，锅炉可分为( )。",[100,102,104,106],{"key":20,"text":101,"correct":25},"立式锅壳锅炉、卧式锅壳锅炉",{"key":24,"text":103,"correct":25},"火管锅炉和水管锅炉",{"key":27,"text":105,"correct":22},"燃油锅炉和蒸汽锅炉",{"key":29,"text":107,"correct":22},"热水锅炉和燃煤锅炉","AB",{"id":110,"libraryId":5,"type":15,"typeLabel":16,"stem":111,"options":112,"answer":121,"analysis":21},881258,"理论循环与实际循环的主要差别在于( )。",[113,115,117,119],{"key":20,"text":114,"correct":25},"忽略了气缸摩擦及无用热交换",{"key":24,"text":116,"correct":22},"忽略了温差",{"key":27,"text":118,"correct":25},"忽略了压缩机吸、排气阀的节流损失",{"key":29,"text":120,"correct":25},"忽略了管道摩擦及无用热交换","ACD",{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":134,"analysis":21},881259,"采用蒸汽供暖系统的工业厂房，其散热器的选用，下列哪几项是错误的？( )",[126,128,130,132],{"key":20,"text":127,"correct":22},"采用铝制散热器",{"key":24,"text":129,"correct":22},"采用水流通道内含砂的铸铁散热器",{"key":27,"text":131,"correct":25},"采用钢制板型散热器",{"key":29,"text":133,"correct":25},"采用钢制扁管散热器","CD",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":44,"analysis":21},881260,"公共建筑设计风机盘管加新风系统时，新风不宜经过风机盘管机组后再送出，其原因应是下列选项中的哪几项？",[139,141,143,145],{"key":20,"text":140,"correct":25},"风机盘管不运行时，易造成该房间的新风不足",{"key":24,"text":142,"correct":22},"风机盘管低速运行时，易造成该房间的新风不足",{"key":27,"text":144,"correct":25},"会降低房间的换气次数(与新风直接送入房间相比)",{"key":29,"text":146,"correct":22},"会降低风机盘管的制冷(制热)能力",{"id":148,"libraryId":5,"type":72,"typeLabel":73,"stem":21,"options":149,"answer":27,"analysis":21},881261,[150,152,154,156],{"key":20,"text":151,"correct":22},"120t\u002Fh",{"key":24,"text":153,"correct":22},"200t\u002Fh",{"key":27,"text":155,"correct":25},"440t\u002Fh",{"key":29,"text":157,"correct":22},"620t\u002Fh",{"id":159,"libraryId":5,"type":72,"typeLabel":73,"stem":160,"options":161,"answer":20,"analysis":21},881262,"同一供暖系统中的同一型号散热器，分别采用以下四种安装方式时，散热量最大的是哪一种？",[162,163,164,165],{"key":20,"text":21,"correct":25},{"key":24,"text":21,"correct":22},{"key":27,"text":21,"correct":22},{"key":29,"text":21,"correct":22},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":108,"analysis":21},881263,"对于居住建筑，严寒和寒冷地区的气候子区是根据下列哪些划分的？( )",[170,172,174,176],{"key":20,"text":171,"correct":25},"供暖度日数",{"key":24,"text":173,"correct":25},"空调度日数",{"key":27,"text":175,"correct":22},"设计计算用供暖期天数",{"key":29,"text":177,"correct":22},"最冷月平均温度",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":121,"analysis":21},881264,"关于夏季空调房间的计算散湿量的组成描述，正确的应是下列哪几项？( )",[182,184,186,188],{"key":20,"text":183,"correct":25},"空调房间的计算散湿量的组成包括了室内设备的散湿量",{"key":24,"text":185,"correct":22},"空调房间的计算散湿量的组成包括了室内人员所需新风的散湿量",{"key":27,"text":187,"correct":25},"空调房间的计算散湿量的组成包括了室内人员的散湿量",{"key":29,"text":189,"correct":25},"空调房间的计算散湿量的组成包括了室内各种液面的散湿量",{"id":191,"libraryId":5,"type":72,"typeLabel":73,"stem":192,"options":193,"answer":27,"analysis":21},881265,"北京某办公楼进行建筑热工设计时，应遵循哪个气候分区的节能设计标准？( )",[194,196,198,200],{"key":20,"text":195,"correct":22},"严寒地区A区",{"key":24,"text":197,"correct":22},"严寒地区B区",{"key":27,"text":199,"correct":25},"寒冷地区",{"key":29,"text":201,"correct":22},"寒冷B区",{"id":203,"libraryId":5,"type":72,"typeLabel":73,"stem":204,"options":205,"answer":20,"analysis":21},881266,"室温允许波动范围为±1℃的工艺性空调，其换气次数不宜小于( )。",[206,208,210,212],{"key":20,"text":207,"correct":25},"5次\u002Fh",{"key":24,"text":209,"correct":22},"8次\u002Fh",{"key":27,"text":211,"correct":22},"10次\u002Fh",{"key":29,"text":213,"correct":22},"16次\u002Fh",{"id":215,"libraryId":5,"type":72,"typeLabel":73,"stem":216,"options":217,"answer":20,"analysis":21},881267,"战时为物资库的人防地下室通风系统按规范规定( )。",[218,220,222,224],{"key":20,"text":219,"correct":25},"应设粗效过滤器",{"key":24,"text":221,"correct":22},"宜设粗效过滤器",{"key":27,"text":223,"correct":22},"不应设粗效过滤器",{"key":29,"text":225,"correct":22},"可不设粗效过滤器",{"id":227,"libraryId":5,"type":72,"typeLabel":73,"stem":228,"options":229,"answer":29,"analysis":21},881268,"冰蓄冷系统中乙烯乙二醇管路中阀门及附件的设置符合要求的是下列哪一项？( )",[230,232,234,236],{"key":20,"text":231,"correct":22},"设置安全阀、电子膨胀阀和自动排气阀",{"key":24,"text":233,"correct":22},"设置安全阀、电子膨胀阀和动态流量平衡阀(多个蓄冷槽并联，管路异程布置时)",{"key":27,"text":235,"correct":22},"设置安全阀和电子膨胀阀，管路系统最低点设置排液管和阀门",{"key":29,"text":237,"correct":25},"设置安全阀、自动排气阀，管路系统最低点设置排液管和阀门",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":250,"analysis":21},881269,"南京某住宅楼进行冬季供暖，下列哪些方式是适宜的？( )",[242,244,246,248],{"key":20,"text":243,"correct":25},"电驱动的热泵机组",{"key":24,"text":245,"correct":25},"低温地面辐射供暖",{"key":27,"text":247,"correct":25},"燃气供暖炉供暖",{"key":29,"text":249,"correct":25},"热水驱动的吸收式冷热机组","ABCD",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":250,"analysis":21},881270,"集中供热系统热源的形式有( )。",[255,257,259,261],{"key":20,"text":256,"correct":25},"热电厂",{"key":24,"text":258,"correct":25},"区域锅炉房",{"key":27,"text":260,"correct":25},"地热",{"key":29,"text":262,"correct":25},"工业余热",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":121,"analysis":21},881271,"采用制冷剂R502的单级压缩式制冷回热循环与不采用回热制冷循环相比较，正确的说法应是下列哪几项？",[267,269,271,273],{"key":20,"text":268,"correct":25},"可提高制冷系数",{"key":24,"text":270,"correct":22},"单位质量工质的冷凝负荷仍维持不变",{"key":27,"text":272,"correct":25},"压缩机的排气温度要升高",{"key":29,"text":274,"correct":25},"压缩机的质量流量要下降",{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":287,"analysis":21},881272,"在分户计量采暖系统设计中，户间传热负荷的处理，下列哪几项是正确的？",[279,281,283,285],{"key":20,"text":280,"correct":22},"应计入采暖系统的总热负荷，用于室外管网的设计",{"key":24,"text":282,"correct":25},"应计入各房间的总热负荷，用于其采暖设备的计算",{"key":27,"text":284,"correct":25},"应计入户内系统各管段的总热负荷，用于其管径的设计计算",{"key":29,"text":286,"correct":22},"应计算户外系统各管段的总热负荷，用于其管径的设计计算","BC",{"id":289,"libraryId":5,"type":72,"typeLabel":73,"stem":290,"options":291,"answer":24,"analysis":21},881273,"对于室内有洁净要求的房间，为保持室内正压选( )是正确的。",[292,294,296,298],{"key":20,"text":293,"correct":22},"自然进风量与机械进风量之和等于自然排风量与机械排风量之和",{"key":24,"text":295,"correct":25},"机械进风量大于机械排风量",{"key":27,"text":297,"correct":22},"机械进风量大于机械排风量与自然排风量之和",{"key":29,"text":299,"correct":22},"自然进风量与机械进风量之和小于自然排风量与机械排风量之和",{"id":301,"libraryId":5,"type":72,"typeLabel":73,"stem":302,"options":303,"answer":20,"analysis":21},881274,"标准蒸汽是指( )。",[304,306,308,310],{"key":20,"text":305,"correct":25},"1标准大气压下的干饱和蒸汽，比焓为2676kJ\u002Fkg",{"key":24,"text":307,"correct":22},"1标准大气压下的干饱和蒸汽，比焓为640kJ\u002Fkg",{"key":27,"text":309,"correct":22},"1标准大气压下的饱和蒸汽，比焓为2676kJ\u002Fkg",{"key":29,"text":311,"correct":22},"1标准大气压下的饱和蒸汽，比焓为640kJ\u002Fkg",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":121,"analysis":21},881275,"对于供热调节，下列说法正确的是( )。",[316,318,320,322],{"key":20,"text":317,"correct":25},"对于只有单一采暖热负荷的热水热力网，应根据室外温度的变化进行中央质调节或中央质-量调节",{"key":24,"text":319,"correct":22},"对有生活热水热负荷的热水热力网，在按采暖热负荷进行中央调节时，应保证闭式热力网任何时候供水温度不低于60℃；开式热力网任何时候供水温度不低于50℃",{"key":27,"text":321,"correct":25},"供给生产工艺热负荷用热的热力网，采用局部调节",{"key":29,"text":323,"correct":25},"当热水热力网有采暖、通风、空调、生活热水多种热负荷时，应按采暖热负荷进行中央调节，并保证运行水温能满足不同热负荷的需要，同时根据各种热负荷的用热要求在用户处进行辅助的局部量调节",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":108,"analysis":21},881276,"设置集中排风系统的公共建筑，设置排风热回收时的条件是( )。",[328,330,331,332],{"key":20,"text":329,"correct":25},"设有独立的排风系统和新风系统",{"key":24,"text":21,"correct":25},{"key":27,"text":21,"correct":22},{"key":29,"text":333,"correct":22},"采用双风机的空调系统",{"id":335,"libraryId":5,"type":72,"typeLabel":73,"stem":336,"options":337,"answer":29,"analysis":21},881277,"中分式热水采暖系统的水平干管上，下连接钢制板型采暖器时，最不好的连接方式应是哪一项？",[338,339,340,341],{"key":20,"text":21,"correct":22},{"key":24,"text":21,"correct":22},{"key":27,"text":21,"correct":22},{"key":29,"text":21,"correct":25},{"id":343,"libraryId":5,"type":72,"typeLabel":73,"stem":344,"options":345,"answer":27,"analysis":21},881278,"制冷系统管路的阻力会导致压缩机的( )。",[346,348,350,352],{"key":20,"text":347,"correct":22},"排气压力升高、吸气压力升高",{"key":24,"text":349,"correct":22},"排气压力降低、吸气压力升高",{"key":27,"text":351,"correct":25},"排气压力升高、吸气压力降低",{"key":29,"text":353,"correct":22},"排气压力降低、吸气压力降低",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":250,"analysis":21},881279,"当消火栓系统和自动喷水灭火系统合用稳压增压设施时，( )。",[358,360,362,364],{"key":20,"text":359,"correct":25},"稳压增压流量和气压罐调节容积应按2个系统叠加确定",{"key":24,"text":361,"correct":25},"稳压增压设施压力应按要求较高的系统确定",{"key":27,"text":363,"correct":25},"出水总管管径不应小于DN100",{"key":29,"text":365,"correct":25},"与2个系统连接前应分别设置止回阀",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":378,"analysis":21},881280,"下列制冷剂中属于HFC物质的有( )。",[370,372,374,376],{"key":20,"text":371,"correct":22},"R22",{"key":24,"text":373,"correct":25},"R134a",{"key":27,"text":375,"correct":22},"R600a",{"key":29,"text":377,"correct":25},"R410A","BD",{"id":380,"libraryId":5,"type":72,"typeLabel":73,"stem":381,"options":382,"answer":27,"analysis":21},881281,"高层民用建筑防烟楼梯间前室、合用前室在采用自然排烟时必须满足的条件是( )。",[383,385,387,389],{"key":20,"text":384,"correct":22},"前室、合用前室外窗面积不小于5.00㎡",{"key":24,"text":386,"correct":22},"前室、合用前室外窗面积不小于3.00㎡",{"key":27,"text":388,"correct":25},"防烟楼梯间前室、消防电梯间前室可开启外窗面积不应小于2.00㎡，合用前室不应小于3.00㎡",{"key":29,"text":390,"correct":22},"前室、合用前室可开启外窗面积不小于3.00㎡",{"id":392,"libraryId":5,"type":72,"typeLabel":73,"stem":393,"options":394,"answer":24,"analysis":21},881282,"绿色居住建筑要求可再生能源的使用量占建筑总能耗的比例大于( )。",[395,397,399,401],{"key":20,"text":396,"correct":22},"3%",{"key":24,"text":398,"correct":25},"5%",{"key":27,"text":400,"correct":22},"7%",{"key":29,"text":402,"correct":22},"10%",{"id":404,"libraryId":5,"type":72,"typeLabel":73,"stem":405,"options":406,"answer":24,"analysis":21},881283,"绿色建筑在自然通风条件下，房间的屋顶和东、西向外墙内表面最高温度不超过( )。",[407,409,411,413],{"key":20,"text":408,"correct":22},"当地最热月的最高温度",{"key":24,"text":410,"correct":25},"当地夏季室外计算温度最高值",{"key":27,"text":412,"correct":22},"当地最热月的最高温度的平均值",{"key":29,"text":414,"correct":22},"35℃",{"id":416,"libraryId":5,"type":72,"typeLabel":73,"stem":417,"options":418,"answer":24,"analysis":21},881284,"严寒地区设置集中供暖的公共建筑和工业建筑，如果不设置值班供暖，利用工作时间内供暖系统蓄热量维持非工作时间内室温应该为( )。",[419,421,423,425],{"key":20,"text":420,"correct":22},"必须达到5℃",{"key":24,"text":422,"correct":25},"必须在0℃以上",{"key":27,"text":424,"correct":22},"10℃",{"key":29,"text":426,"correct":22},"设计温度",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":69,"analysis":21},881285,"静电除尘器电场必须具备下列哪些条件才能有效工作？( )",[431,433,435,437],{"key":20,"text":432,"correct":25},"高压",{"key":24,"text":434,"correct":25},"直流",{"key":27,"text":436,"correct":22},"高电流",{"key":29,"text":438,"correct":25},"不均匀",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":250,"analysis":21},881286,"上海市某办公楼采用多联机空调方案，建筑专业在该建筑物设置了自然通风井，并在办公室外墙上设置了可开关的通风窗，下列说法中不正确的是( )。",[443,445,447,449],{"key":20,"text":444,"correct":25},"设置自然通风会增加室外空气渗透量，因此会使空调能耗增加",{"key":24,"text":446,"correct":25},"为了充分发挥自然通风效果，自然通风窗应一直处于开启状态",{"key":27,"text":448,"correct":25},"自然通风窗应在有人时开启、无人时关闭",{"key":29,"text":450,"correct":25},"自然通风窗应在无人时开启、有人时关闭",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":31,"analysis":21},881287,"对严寒和寒冷地区居住建筑采暖计算的做法中，正确的是哪几项？",[455,457,459,461],{"key":20,"text":456,"correct":22},"建筑物耗热量指标由采暖热负荷计算后得出",{"key":24,"text":458,"correct":25},"外墙传热系数计算是考虑了热桥影响后计算得到的平均传热系数",{"key":27,"text":460,"correct":25},"在对外门窗的耗热量计算中，应减去采暖期平均太阳辐射热",{"key":29,"text":462,"correct":25},"负荷计算中，考虑相当建筑物体积0.5次\u002Fh的换气耗热量",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":69,"analysis":21},881288,"设计建筑室内排水系统时，可选用的管材是下列哪几项？( )",[467,469,471,473],{"key":20,"text":468,"correct":25},"硬聚氯乙烯塑料排水管",{"key":24,"text":470,"correct":25},"聚乙烯塑料排水管",{"key":27,"text":472,"correct":22},"砂模铸造铸铁排水管",{"key":29,"text":474,"correct":25},"柔性接口机制铸铁排水管",{"id":476,"libraryId":5,"type":72,"typeLabel":73,"stem":477,"options":478,"answer":20,"analysis":21},881289,"室内热水供暖系统中，水在散热器和管道中冷却而产生自然作用压力，对下列哪种系统的影响最大？( )",[479,481,483,485],{"key":20,"text":480,"correct":25},"高层建筑的垂直双管系统",{"key":24,"text":482,"correct":22},"环路较长的单层建筑水平双管系统",{"key":27,"text":484,"correct":22},"高层建筑的垂直单管系统",{"key":29,"text":486,"correct":22},"环路较长的所有系统",{"id":488,"libraryId":5,"type":72,"typeLabel":73,"stem":489,"options":490,"answer":20,"analysis":21},881290,"一般情况下，围护结构外表面表面传热系数( )内表面表面传热系数。",[491,493,495,497],{"key":20,"text":492,"correct":25},"大于",{"key":24,"text":494,"correct":22},"等于",{"key":27,"text":496,"correct":22},"小于",{"key":29,"text":498,"correct":22},"不可确定",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":287,"analysis":21},881291,"热水吊顶辐射板供暖设计中，做法错误的是( )。",[503,505,507,509],{"key":20,"text":504,"correct":22},"屋顶耗热量大于房间总耗热量的30%时，应加强屋顶保温措施",{"key":24,"text":506,"correct":25},"安装吊顶辐射板时，宜按最短的外墙布置",{"key":27,"text":508,"correct":25},"热水吊顶辐射板安装高度为3m，平均水温80℃",{"key":29,"text":510,"correct":22},"热水吊顶辐射板供暖可用于层高3～30m的建筑物",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":121,"analysis":21},881292,"以下哪些是对制冷剂在热力学性质方面的要求？( )。",[515,517,519,521],{"key":20,"text":516,"correct":25},"制冷剂的临界点应远离制冷循环的工作区域",{"key":24,"text":518,"correct":22},"制冷剂的单位容积制冷量尽可能大",{"key":27,"text":520,"correct":25},"制冷剂的凝固温度低",{"key":29,"text":522,"correct":25},"制冷剂的蒸发压力最好不低于大气压力",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":134,"analysis":21},881293,"关于非等温自由射流，叙述正确的是( )。",[527,529,531,533],{"key":20,"text":528,"correct":22},"送风温度高于室内空气温度时为冷射流",{"key":24,"text":530,"correct":22},"非等温射流进入房间后，热量交换快于动量交换，因而温度衰减快于速度衰减",{"key":27,"text":532,"correct":25},"非等温射流在其射程中，由于与周围空气密度不同，所受浮力与重力不同而发生弯曲，冷射流向下弯曲",{"key":29,"text":534,"correct":25},"决定射流弯曲程度的主要因素是阿基米德数，是表征浮力和惯性力的无因次比值",{"id":536,"libraryId":5,"type":72,"typeLabel":73,"stem":537,"options":538,"answer":29,"analysis":21},881294,"转速发生变化后，( )是正确的。",[539,541,543,545],{"key":20,"text":540,"correct":22},"风机风量不变",{"key":24,"text":542,"correct":22},"风机风压不变",{"key":27,"text":544,"correct":22},"风机功率不变",{"key":29,"text":546,"correct":25},"风机全压效率不变",{"id":548,"libraryId":5,"type":72,"typeLabel":73,"stem":549,"options":550,"answer":20,"analysis":21},881295,"天窗采光面积大，窗孔集中在车间中部，当热源集中在室内中部时，便于气流迅速排除的天窗是( )。",[551,553,555,557],{"key":20,"text":552,"correct":25},"矩形天窗",{"key":24,"text":554,"correct":22},"下沉式天窗",{"key":27,"text":556,"correct":22},"曲(折)线形天窗",{"key":29,"text":558,"correct":22},"普通天窗",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":571,"analysis":21},881296,"在冬季建筑热负荷计算中，下列哪几种计算方法是错误的？",[563,565,567,569],{"key":20,"text":564,"correct":25},"阳台门按其所在楼层做围护结构耗热量附加",{"key":24,"text":566,"correct":25},"多层建筑有两面外窗房间的冷风渗透量可按房间的1.0-1.5次\u002Fh换气量计算",{"key":27,"text":568,"correct":25},"严寒地区地面辐射采暖热负荷可取对流采暖系统计算总热负荷的90%",{"key":29,"text":570,"correct":22},"小学教学楼热负荷为基本耗热量的120%","ABC",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":69,"analysis":21},881297,"下列关于空调建筑的外窗遮阳系数的叙述，错误的是( )。",[576,578,580,582],{"key":20,"text":577,"correct":25},"严寒地区宜大于0.80",{"key":24,"text":579,"correct":25},"非严寒地区宜小于0.65",{"key":27,"text":581,"correct":22},"严寒地区宜小于0.80",{"key":29,"text":583,"correct":25},"当外窗遮阳系数不满足规范要求时，应采取外遮阳措施",{"id":585,"libraryId":5,"type":72,"typeLabel":73,"stem":586,"options":587,"answer":27,"analysis":21},881298,"洁净室静态是下列( )所描述的状态。",[588,590,592,594],{"key":20,"text":589,"correct":22},"设施已建成，所有动力接通并运行，但无生产设备、材料及人员",{"key":24,"text":591,"correct":22},"设施已建成，生产设备已经安装，但无生产人员",{"key":27,"text":593,"correct":25},"设施已建成，生产设备已经安装并按甲乙双方约定的状态运行，但无生产人员",{"key":29,"text":595,"correct":22},"设施已建成，生产设备已经安装并按甲乙双方约定的状态运行",{"id":597,"libraryId":5,"type":72,"typeLabel":73,"stem":598,"options":599,"answer":29,"analysis":21},881299,"R407C是由( )按一定质量百分数混合而成的非共沸制冷剂。",[600,602,604,606],{"key":20,"text":601,"correct":22},"R22，R125，R134a",{"key":24,"text":603,"correct":22},"R134a，R125，R143a",{"key":27,"text":605,"correct":22},"R22，R32，R125",{"key":29,"text":607,"correct":25},"R134a，R125，R32",{"id":609,"libraryId":5,"type":72,"typeLabel":73,"stem":610,"options":611,"answer":27,"analysis":21},881300,"空调系统采用湿膜加湿，加湿水温与空气湿球温度相同，则加湿段冬季空气处理过程为( )。",[612,614,616,618],{"key":20,"text":613,"correct":22},"空气温度下降、相对湿度增加、比焓增加",{"key":24,"text":615,"correct":22},"空气温度基本不变、相对湿度增加、比焓增加",{"key":27,"text":617,"correct":25},"空气温度下降、含湿量增加、比焓基本不变",{"key":29,"text":619,"correct":22},"空气温度下降、含湿量增加、比焓减少",[621,624,627,630,633,636],{"id":72,"name":622,"category":7,"favorite":623},"领导干部任职前廉政法规知识测试题",92,{"id":625,"name":626,"category":7,"favorite":72},595,"建筑结构与设备",{"id":628,"name":629,"category":7,"favorite":72},715,"招标采购专业知识与法律法规",{"id":631,"name":632,"category":7,"favorite":72},848,"市政方向-通用基础",{"id":634,"name":635,"category":7,"favorite":8},534,"BIM工程师",{"id":637,"name":635,"category":7,"favorite":8},535]