[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-28":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":624},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,28,50,2054,[13,35,48,61,74,86,99,111,123,136,148,160,173,185,197,209,222,234,246,258,269,281,294,307,319,330,342,354,366,374,386,398,410,422,434,446,458,470,482,494,506,518,530,542,554,566,576,588,600,612],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},881201,2,"多选题","某小区现有建筑均为多层，各供暖系统静水压力均不大于0.3MPa，现拟建一高层建筑，其供暖系统最高点静水压力为0.5MPa，试问该建筑与外网的连接方式下列哪几项是正确的(散热设备为铸铁散热器)？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","设换热器与外网间接连接",false,{"key":24,"text":25,"correct":26},"B","建筑内分高低区供暖系统，低区与外网连接，高区设换热器与外网连接",true,{"key":28,"text":29,"correct":26},"C","建筑内分高低区供暖系统，低区与外网连接，高区采用双水箱分层式系统与外网连接",{"key":31,"text":32,"correct":22},"D","设混水泵与外网直接连接","BC","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},881202,"不适用于室外管网供水压力周期性不足情况的给水方式是( )。",[39,41,43,45],{"key":20,"text":40,"correct":22},"单设水箱的给水方式",{"key":24,"text":42,"correct":26},"变频泵的给水方式",{"key":28,"text":44,"correct":26},"设水泵和水箱的给水方式",{"key":31,"text":46,"correct":26},"气压给水方式","BCD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},881203,"关于通风系统设计，正确的是( )。",[52,54,56,58],{"key":20,"text":53,"correct":26},"一般通风系统设计计算两并联支管压力损失的相对差额不宜超过15%",{"key":24,"text":55,"correct":26},"输送高温烟气的管道应采用热补偿措施",{"key":28,"text":57,"correct":26},"合理布置风管可以减小风道阻力",{"key":31,"text":59,"correct":26},"输送空气温度超过80℃的通风管道，应采用保温隔热措施，其厚度按隔热层外表面温度不超过80℃确定","ABCD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},881204,"民用建筑供暖全年耗热量与下列哪些因素有关？( )",[65,67,69,71],{"key":20,"text":66,"correct":26},"设计计算用供暖期天数",{"key":24,"text":68,"correct":26},"供暖设计热负荷",{"key":28,"text":70,"correct":26},"供暖期室外平均温度",{"key":31,"text":72,"correct":22},"供暖期累年最冷日平均温度","ABC",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":73,"analysis":34},881205,"空调冷水系统应采用二次泵系统的情况，是下列哪些项？",[78,80,82,84],{"key":20,"text":79,"correct":26},"各环路压力损失相差悬殊",{"key":24,"text":81,"correct":26},"各环路负荷特性相差悬殊",{"key":28,"text":83,"correct":26},"系统阻力较高(大)",{"key":31,"text":85,"correct":22},"冷水系统采用变速变流量调节方式",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":98,"analysis":34},881206,"选择供暖散热器时，应符合下列哪几项规定？( )",[90,92,94,96],{"key":20,"text":91,"correct":26},"散热器的工作压力应满足系统的工作压力，并应符合国家现行有关产品标准规定",{"key":24,"text":93,"correct":22},"蒸汽供暖系统不应采用铸铁散热器",{"key":28,"text":95,"correct":26},"采用钢制散热器时，应采用闭式系统",{"key":31,"text":97,"correct":26},"相对湿度较大的房间应采用耐腐蚀的散热器","ACD",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":73,"analysis":34},881207,"属于玻璃钢开式冷却塔标准设计工况参数的是( )。",[103,105,107,109],{"key":20,"text":104,"correct":26},"工业型冷却塔的设计温差10℃",{"key":24,"text":106,"correct":26},"进风湿球温度28℃",{"key":28,"text":108,"correct":26},"出水温度32℃",{"key":31,"text":110,"correct":22},"出水温度30℃",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":47,"analysis":34},881208,"下列关于降低系统噪声措施的说法中，正确的是( )。",[115,117,119,121],{"key":20,"text":116,"correct":22},"降低噪声最有效的措施是安装消声器",{"key":24,"text":118,"correct":26},"风管上的调节阀不仅会增加阻力，而且会增加噪声，应尽量少装",{"key":28,"text":120,"correct":26},"风管急剧拐弯会产生二次噪声",{"key":31,"text":122,"correct":26},"由于噪声可以通过固体接触传播，因此与电视演播室相邻的空调机房应设置独立基础",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":135,"analysis":34},881209,"变制冷剂流量多联式空调(热泵)机组在大型建筑中应用，其配管长度的限制，下列哪几项是错误的？( )",[127,129,131,133],{"key":20,"text":128,"correct":26},"只要根据厂家样本，一般在150m以下就可以",{"key":24,"text":130,"correct":26},"变制冷剂流量多联式空调(热泵)机组可以超频运行，完全适合长距离运输",{"key":28,"text":132,"correct":22},"最好在100m以下，配管加长使压缩机吸气管阻力增加，系统能耗增加",{"key":31,"text":134,"correct":26},"应在30m以下，配管加长使压缩机吸气管阻力增加，过热增加，系统远端机组除湿能力降低","ABD",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":73,"analysis":34},881210,"冰蓄冷系统运行控制策略有( )。",[140,142,144,146],{"key":20,"text":141,"correct":26},"融冰优先",{"key":24,"text":143,"correct":26},"制冷机优先",{"key":28,"text":145,"correct":26},"优化控制",{"key":31,"text":147,"correct":22},"分步控制",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":98,"analysis":34},881211,"吸收式制冷的最大热力系数与( )有关。",[152,154,156,158],{"key":20,"text":153,"correct":26},"热源温度",{"key":24,"text":155,"correct":22},"冷却介质温度",{"key":28,"text":157,"correct":26},"环境温度",{"key":31,"text":159,"correct":26},"被冷却物质温度",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":172,"analysis":34},881212,"氨制冷系统中，通过管路与自动放气装置连接的设备有下列哪几项？( )",[164,166,168,170],{"key":20,"text":165,"correct":26},"高压储液桶和冷凝器",{"key":24,"text":167,"correct":22},"压缩机的排气侧",{"key":28,"text":169,"correct":22},"低压储液桶和压缩机的吸气侧",{"key":31,"text":171,"correct":26},"水封槽","AD",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":73,"analysis":34},881213,"制冷剂充灌量严重不足时，制冷装置的( )。",[177,179,181,183],{"key":20,"text":178,"correct":26},"吸气压力下降",{"key":24,"text":180,"correct":26},"排气温度上升",{"key":28,"text":182,"correct":26},"制冷量减小",{"key":31,"text":184,"correct":22},"冷凝压力提高",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":33,"analysis":34},881214,"关于共沸溶液，下列说法正确的是( )。",[189,191,193,195],{"key":20,"text":190,"correct":22},"共沸溶液制冷剂在标准大气压力下的蒸发温度一般比组成其组分的蒸发温度高",{"key":24,"text":192,"correct":26},"在同一蒸发温度下，由于共沸溶液制冷剂的蒸发压力比其组分的蒸发压力高",{"key":28,"text":194,"correct":26},"与R22相比，采用R502的单级压缩机，制冷量可增加5%～30%，在低温下制冷量增加较大",{"key":31,"text":196,"correct":22},"相同工况下，R502的排气温度比R22高10～25℃",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":73,"analysis":34},881215,"在设计常年不间断供热锅炉房的热水管道时，下列哪些做法是正确的？( )",[201,203,205,207],{"key":20,"text":202,"correct":26},"热水管道的高点装设公称直径为20mm的放气阀",{"key":24,"text":204,"correct":26},"热水管道采用双母管",{"key":28,"text":206,"correct":26},"每台锅炉采用独立的定期排污管道",{"key":31,"text":208,"correct":22},"锅炉的排污阀及其管道采用螺纹连接",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":221,"analysis":34},881216,"在小区锅炉房的设计原则中，下列哪些说法是正确的？( )",[213,215,217,219],{"key":20,"text":214,"correct":26},"锅炉房设计总容量应考虑室外管网的热损失",{"key":24,"text":216,"correct":22},"锅炉房进行改扩建，其总台数不宜超过5台",{"key":28,"text":218,"correct":26},"每个新建锅炉房(燃煤、燃气、燃油)只能设1个烟囱，其高度应符合烟囱排风浓度要求",{"key":31,"text":220,"correct":22},"燃煤锅炉房总容量为2.8～7MW(不含7MW)时，其烟囱的最低高度应＞35m","AC",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":73,"analysis":34},881217,"下列关于公共建筑热水采暖系统散热器设计选型、安装的表述，哪些是正确的？",[226,228,230,232],{"key":20,"text":227,"correct":26},"确定散热器所需散热量时，应扣除室内明装管道的散热量",{"key":24,"text":229,"correct":26},"散热器宜明装",{"key":28,"text":231,"correct":26},"散热器的外表面应刷非金属性涂料",{"key":31,"text":233,"correct":22},"钢制柱形散热器的片数不应超过20片",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":47,"analysis":34},881218,"多层建筑物下列哪些部位的歌舞厅应设排烟设施？( )",[238,240,242,244],{"key":20,"text":239,"correct":22},"面积150㎡的2层房间",{"key":24,"text":241,"correct":26},"面积250㎡的3层房间",{"key":28,"text":243,"correct":26},"面积100㎡的4层房间",{"key":31,"text":245,"correct":26},"面积100㎡的地下房间",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":98,"analysis":34},881219,"下列对于室内燃气管道的最高工作表压力的选择，正确的是( )。",[250,252,254,256],{"key":20,"text":251,"correct":26},"工业用户及单独的锅炉房0.4MPa",{"key":24,"text":253,"correct":22},"公共建筑用户0.3MPa",{"key":28,"text":255,"correct":26},"公共建筑和居民住宅用户(中压进户)0.2MPa",{"key":31,"text":257,"correct":26},"公共建筑和居民住宅用户(低压进户)0.01MPa",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":73,"analysis":34},881220,"关于围护结构最小传热阻的要求，正确的是( )。",[262,264,265,267],{"key":20,"text":263,"correct":26},"寒冷地区住宅Ⅳ型围护结构东西向外墙应进行夏季隔热验算",{"key":24,"text":34,"correct":26},{"key":28,"text":266,"correct":26},"采用离心玻璃棉板内保温的混凝土外墙应进行传热阻附加",{"key":31,"text":268,"correct":22},"间歇供暖的建筑围护结构应进行传热阻附加",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":221,"analysis":34},881221,"在机械循环中，膨胀水箱的主要作用是( )。",[273,275,277,279],{"key":20,"text":274,"correct":26},"容纳水受热膨胀而增加的体积",{"key":24,"text":276,"correct":22},"排除系统中的空气",{"key":28,"text":278,"correct":26},"恒定水泵的人口压力",{"key":31,"text":280,"correct":22},"驱动水在系统中循环流动",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":293,"analysis":34},881222,"单级蒸气压缩制冷循环，压缩机排气管道存在的压力降，对制冷循环性能有哪些影响？( )",[285,287,289,291],{"key":20,"text":286,"correct":26},"压缩机排气压力增加",{"key":24,"text":288,"correct":26},"压缩机容积效率降低",{"key":28,"text":290,"correct":22},"系统制冷系数增加",{"key":31,"text":292,"correct":22},"压缩机制冷量增加","AB",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":306,"analysis":34},881223,"共用立管的水平单管式热水供暖系统，重力循环作用压头与下列哪些因素无关？( )",[298,300,302,304],{"key":20,"text":299,"correct":22},"立管供、回水温度",{"key":24,"text":301,"correct":22},"散热器与热源的高差",{"key":28,"text":303,"correct":26},"散热器散热量",{"key":31,"text":305,"correct":26},"水平方向散热器数量","CD",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":221,"analysis":34},881224,"某建筑的一次泵空调水系统，设有3台冷水机组和3台与机组连锁的冷水泵。三台同时运行时，冷水泵的运行参数符合设计要求；当1台冷水机组和1台冷水泵运行时，冷水机组处于低负荷状态，却发现建筑内的部分空调房间实际温度高于设计值。产生上述问题的原因分析及应采取的措施，正确的是下列哪几项？",[311,313,315,317],{"key":20,"text":312,"correct":26},"温度高的房间的末端设备的设计冷量不够，应加大末端设备容量",{"key":24,"text":314,"correct":22},"冷水机组的制冷量不足，应加大制冷机组的容量",{"key":28,"text":316,"correct":26},"房间的末端设备无自控措施(或自控失灵)，应增加(或检修)自控系统",{"key":31,"text":318,"correct":22},"该冷水泵的水流量不能满足要求，应加大水泵流量或再投入一台泵运行",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":321,"answer":306,"analysis":34},881225,[322,324,326,328],{"key":20,"text":323,"correct":22},"电动机功率等于水泵设计参数时所对应的配电机功率",{"key":24,"text":325,"correct":22},"电动机功率小于水泵设计参数时所对应的配电机功率",{"key":28,"text":327,"correct":26},"电动机功率大于水泵设计参数时所对应的配电机功率",{"key":31,"text":329,"correct":26},"电动机功率的配置与水泵的性能曲线有关",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":306,"analysis":34},881226,"机械排烟可分为( )。",[334,336,338,340],{"key":20,"text":335,"correct":22},"机械加压",{"key":24,"text":337,"correct":22},"机械减压",{"key":28,"text":339,"correct":26},"集中排烟",{"key":31,"text":341,"correct":26},"局部排烟",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":33,"analysis":34},881227,"某写字楼建筑设计为一个集中式中央空调系统，房间采用风机盘管十新风系统方式，下列确定冷水机组制冷量(不计附加因素)的做法，下列哪几项是错误的?( )。",[346,348,350,352],{"key":20,"text":347,"correct":22},"冷水机组的制冷量一全部风机盘管(中速)的额定制冷量十新风机组的冷量",{"key":24,"text":349,"correct":26},"冷水机组的制冷量一全部风机盘管(高速)的额定制冷量十新风机组的冷量",{"key":28,"text":351,"correct":26},"冷水机组的制冷量一逐项逐时计算的最大小时冷负荷×大于1的同时使用系数",{"key":31,"text":353,"correct":22},"冷水机组的制冷量一逐项逐时计算的最大小时冷负荷×小于1的同时使用系数",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":135,"analysis":34},881228,"关于集中空调水系统的说法，下列哪几项是正确的？( )",[358,360,362,364],{"key":20,"text":359,"correct":26},"冷却效果相同时，多台冷却塔同步变频调节风机转速比冷却塔台数控制更节能",{"key":24,"text":361,"correct":26},"水源热泵机组采用地下水或地表水作为分散小型单元式机组的水源时，应采用板式换热器的间接供水方式",{"key":28,"text":363,"correct":22},"在空调水系统中，定压点的最低压力应保证水系统最高点的压力高于大气压力4kPa",{"key":31,"text":365,"correct":26},"水环热泵空调系统使用开式冷却塔时，应设置中间换热器",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":73,"analysis":34},881229,"某工艺性空调房间尺寸为6.0m×4.0mX3.0m，要求恒温为(20±0.5)℃，房间冷负荷为1200W，湿负荷为0，则送风量为( )时能满足气流组织要求。",[370,371,372,373],{"key":20,"text":34,"correct":26},{"key":24,"text":34,"correct":26},{"key":28,"text":34,"correct":26},{"key":31,"text":34,"correct":22},{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":98,"analysis":34},881230,"关于空气过滤器的选择，下列表述正确的是( )。",[378,380,382,384],{"key":20,"text":379,"correct":26},"高效过滤器用于万级以上的洁净室、无菌病房、无菌灌装室、无菌动物房等净化空调",{"key":24,"text":381,"correct":22},"中效过滤器对微生物有很高的过滤效率",{"key":28,"text":383,"correct":26},"粗效过滤器用于新风过滤",{"key":31,"text":385,"correct":26},"中效过滤器用作高效过滤器的前级保护",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":135,"analysis":34},881231,"下列有关建筑热工设计分区论述正确的是( )。",[390,392,394,396],{"key":20,"text":391,"correct":26},"夏热冬冷地区必须满足夏季防热要求",{"key":24,"text":393,"correct":26},"严寒地区一般可不考虑夏季防热",{"key":28,"text":395,"correct":22},"温和地区应考虑冬季保温",{"key":31,"text":397,"correct":26},"夏热冬暖地区一般可不考虑冬季保温",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":306,"analysis":34},881232,"一栋25层建筑，防烟楼梯间及合用前室分别设有机械加压送风系统，所选用的风机全压在满足最不利环路管道的压力损失以外，防烟楼梯间的余压为 A，合用前室的余压为Ba符合现行国家标准规定的正确余压数值是下列哪几项？( )",[402,404,406,408],{"key":20,"text":403,"correct":22},"A=50Pa，B=30Pa",{"key":24,"text":405,"correct":22},"A=40Pa，B=25Pa",{"key":28,"text":407,"correct":26},"A=45Pa，B=27.5Pa",{"key":31,"text":409,"correct":26},"A=50Pa，B=25Pa",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":98,"analysis":34},881233,"凝结水回收系统中，余压回水的主要特点有( )。",[414,416,418,420],{"key":20,"text":415,"correct":26},"疏水器后管道流动属于两相流",{"key":24,"text":417,"correct":22},"凝结水管径较粗",{"key":28,"text":419,"correct":26},"凝结水管径较细",{"key":31,"text":421,"correct":26},"系统作用半径较大",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":293,"analysis":34},881234,"关于低温送风系统，下列说法正确的是( )。",[426,428,430,432],{"key":20,"text":427,"correct":26},"低温送风系统常与冰蓄冷系统联合应用",{"key":24,"text":429,"correct":26},"采用低温送风系统，可将室内设计温度提高1～2℃，因此节省了运行费用",{"key":28,"text":431,"correct":22},"为防止风口结露，宜采用多层百叶风口",{"key":31,"text":433,"correct":22},"低温送风风管宜采用圆形风管或矩形风管",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":135,"analysis":34},881235,"在洁净室管线敷设中，关于气体配管系统的布置，下列说法正确的是( )。",[438,440,442,444],{"key":20,"text":439,"correct":26},"气体管路应尽量短捷，以减少输送过程中高纯气体受到的污染",{"key":24,"text":441,"correct":26},"管线布置及其周围环境要考虑到防火防爆及气体泄漏后的排除",{"key":28,"text":443,"correct":22},"气体管道可以与水系统的压力管道和电气线路共同支架",{"key":31,"text":445,"correct":26},"在洁净厂房内，即使使用高纯气瓶，也不允许直接放在洁净室内生产设备远处",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":172,"analysis":34},881236,"下列设备和管道安装时，哪些说法是正确的?( )。",[450,452,454,456],{"key":20,"text":451,"correct":26},"A.热量表安装时，上游侧直管段长度不应小于5下游侧直管段长度不应小于2D",{"key":24,"text":453,"correct":22},"风管测定孔与前后局部配件间的距离宜分别保持不小于5D和2D",{"key":28,"text":455,"correct":22},"矩形风管平面边长大于500mm，且曲率半径小于1倍的平面边长时，应设置弯管导流叶片",{"key":31,"text":457,"correct":26},"制冷剂管道弯管的弯曲半径不应小于3.5D",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":306,"analysis":34},881237,"关于耐火等级，下列说法错误的是( )。",[462,464,466,468],{"key":20,"text":463,"correct":22},"高层建筑的耐火等级应分为一、二两级",{"key":24,"text":465,"correct":22},"一类高层建筑的耐火等级应为一级",{"key":28,"text":467,"correct":26},"二类高层建筑的耐火等级应为二级",{"key":31,"text":469,"correct":26},"裙房的耐火等级为二级，高层建筑地下室的耐火等级为一级",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":60,"analysis":34},881238,"下列关于空调工况区划分，正确的说法是( )",[474,476,478,480],{"key":20,"text":475,"correct":26},"空调系统确定后，可根据当地气象变化，将i-d图分成若干个气象区(空调工况区)，对应于每一个工况区采用不同的运行调节方法",{"key":24,"text":477,"correct":26},"在保证室内温湿度要求的前提下，各分区中系统运行经济",{"key":28,"text":479,"correct":26},"应保证空调系统在各分区中一年中有一定的运行时数",{"key":31,"text":481,"correct":26},"空调工况分区时，可用焓作为室外空气状态变化的指标",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":73,"analysis":34},881239,"供暖冷风渗透耗热量计算，应包括的内容下列哪几项是正确的？( )",[486,488,490,492],{"key":20,"text":487,"correct":26},"当房间仅有一面或相邻两面外围护物时，全部计入其外门、窗的缝隙",{"key":24,"text":489,"correct":26},"当房间有相对两面外围护物时，仅计入较大的一面缝隙",{"key":28,"text":491,"correct":26},"当房间有三面围护物时，仅计入风量较大的两面的缝隙",{"key":31,"text":493,"correct":22},"当房间有四面围护物时，仅计入风量较大的三面的缝隙",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":60,"analysis":34},881240,"房间的总失热量包括( )。",[498,500,502,504],{"key":20,"text":499,"correct":26},"围护结构传热耗热量",{"key":24,"text":501,"correct":26},"冷风渗透耗热量",{"key":28,"text":503,"correct":26},"冷风侵入耗热量",{"key":31,"text":505,"correct":26},"通风耗热量",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":306,"analysis":34},881241,"下列关于冷水表冷器和热水加热器的接管和控制方式，正确的说法是( )。",[510,512,514,516],{"key":20,"text":511,"correct":22},"在变流量式水系统中，只能采用二通调节阀",{"key":24,"text":513,"correct":22},"三通调节阀只适用于定流量式水系统",{"key":28,"text":515,"correct":26},"只要采用适当的接管方式，三通调节阀可用于变流量式水系统",{"key":31,"text":517,"correct":26},"二通调节阀也可用于定流量式水系统",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":73,"analysis":34},881242,"下列热负荷属于季节性热负荷的是( )。",[522,524,526,528],{"key":20,"text":523,"correct":26},"空气调节热负荷",{"key":24,"text":525,"correct":26},"供暖热负荷",{"key":28,"text":527,"correct":26},"通风系统热负荷",{"key":31,"text":529,"correct":22},"生活热水供应热负荷",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":293,"analysis":34},881243,"按照相关节能设计标准，一栋体形系数为0.35的办公楼，外墙传热系数为0.55，该参数满足哪个气候区对外墙的热工要求？( )",[534,536,538,540],{"key":20,"text":535,"correct":26},"夏热冬冷气候区",{"key":24,"text":537,"correct":26},"夏热冬暖气候区",{"key":28,"text":539,"correct":22},"寒冷气候区",{"key":31,"text":541,"correct":22},"严寒气候区",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":221,"analysis":34},881244,"多层建筑的通风空调风管经过下列哪些房间的隔墙时应设防火阀？( )",[546,548,550,552],{"key":20,"text":547,"correct":26},"面积为100㎡的多功能厅",{"key":24,"text":549,"correct":22},"地下一层面积＜200㎡的水泵房",{"key":28,"text":551,"correct":26},"人民防空工程中设防火门的房间",{"key":31,"text":553,"correct":22},"地下一层面积为500㎡的戊类仓库",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":73,"analysis":34},881245,"下列关于穿透率的说法，正确的是( )。",[558,560,562,564],{"key":20,"text":559,"correct":26},"穿透率可以用来评价过滤器的好坏",{"key":24,"text":561,"correct":26},"穿透率是指过滤后空气的含尘浓度与过滤前空气的含尘浓度之比的百分数",{"key":28,"text":563,"correct":26},"引用穿透率这一概念的意义在于可用它明确表示过滤器前后的空气含尘量",{"key":31,"text":565,"correct":22},"穿透率是反映过滤器的通过能力和安装面积的性能指标",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":98,"analysis":34},881246,"以下室内燃气管道的最高工作表压力选择正确的是( )。",[570,571,572,574],{"key":20,"text":251,"correct":26},{"key":24,"text":253,"correct":22},{"key":28,"text":573,"correct":26},"公共建筑和居民住宅用户(中压迸户)0.2MPa",{"key":31,"text":575,"correct":26},"公共建筑和居民住宅用户(低压进户)0.OIMPa",{"id":577,"libraryId":5,"type":15,"typeLabel":16,"stem":578,"options":579,"answer":293,"analysis":34},881247,"某3层办公建筑的空调水系统调试时，每次开机前必须先补水，否则无法正常运行。分析可能的原因，应是下列哪几项？( )",[580,582,584,586],{"key":20,"text":581,"correct":26},"空调水系统有漏水点",{"key":24,"text":583,"correct":26},"空调水系统管路中含有较多空气(未排净)",{"key":28,"text":585,"correct":22},"水泵的流量不足",{"key":31,"text":587,"correct":22},"膨胀水箱的底部与水系统最高点的高差过大",{"id":589,"libraryId":5,"type":15,"typeLabel":16,"stem":590,"options":591,"answer":73,"analysis":34},881248,"下列( )是滤筒式除尘器的主要性能特点。",[592,594,596,598],{"key":20,"text":593,"correct":26},"滤筒相对同体积的滤袋具有较大的过滤面积",{"key":24,"text":595,"correct":26},"具有较高的除尘效率",{"key":28,"text":597,"correct":26},"滤简易于更换",{"key":31,"text":599,"correct":22},"适合净化各类粉尘",{"id":601,"libraryId":5,"type":15,"typeLabel":16,"stem":602,"options":603,"answer":60,"analysis":34},881249,"蒸汽供热管网中分汽缸上应装设的附件，应是下列哪几项？",[604,606,608,610],{"key":20,"text":605,"correct":26},"压力表",{"key":24,"text":607,"correct":26},"温度计",{"key":28,"text":609,"correct":26},"安全阀",{"key":31,"text":611,"correct":26},"疏水阀",{"id":613,"libraryId":5,"type":15,"typeLabel":16,"stem":614,"options":615,"answer":98,"analysis":34},881250,"关于设备和管道保温，下列说法正确的是( )。",[616,618,620,622],{"key":20,"text":617,"correct":26},"保温层的外表面不得产生凝结水",{"key":24,"text":619,"correct":22},"保温层的外表面允许有少量的凝结水",{"key":28,"text":621,"correct":26},"保温层的外表面应设隔汽层",{"key":31,"text":623,"correct":26},"管道和支架之间应采取防止“冷桥”的措施",[625,629,632,635,638,641],{"id":626,"name":627,"category":7,"favorite":628},1,"领导干部任职前廉政法规知识测试题",92,{"id":630,"name":631,"category":7,"favorite":626},595,"建筑结构与设备",{"id":633,"name":634,"category":7,"favorite":626},715,"招标采购专业知识与法律法规",{"id":636,"name":637,"category":7,"favorite":626},848,"市政方向-通用基础",{"id":639,"name":640,"category":7,"favorite":8},534,"BIM工程师",{"id":642,"name":640,"category":7,"favorite":8},535]