[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-27":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":619},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,27,50,2054,[13,34,41,53,65,77,89,101,113,125,137,149,161,172,184,196,208,220,232,244,256,267,279,291,303,311,323,335,347,359,371,383,395,407,419,431,443,455,467,479,491,503,518,531,544,556,569,582,594,606],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},881151,1,"单选题","关于作用于门窗上的有效热压差与有效风压差之比 C，说法错误的是( )。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","C≤-1的房间无冷风渗入",false,{"key":24,"text":25,"correct":22},"B","C＞-1的房间可能有冷风渗入",{"key":27,"text":28,"correct":29},"C","C≤0的房间一定无冷风渗入",true,{"key":31,"text":32,"correct":22},"D","C的大小与计算门窗的中心线标高有关","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":36,"answer":24,"analysis":33},881152,[37,38,39,40],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":29},{"key":27,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":27,"analysis":33},881153,"某一双极压缩系统，其蒸发温度为10℃，冷凝温度为30℃，其最佳中间温度为( )℃。",[45,47,49,51],{"key":20,"text":46,"correct":22},"19",{"key":24,"text":48,"correct":22},"20",{"key":27,"text":50,"correct":29},"21",{"key":31,"text":52,"correct":22},"22",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":20,"analysis":33},881154,"设在高层建筑内的自动灭火系统的设备室，通风、空调机房，其防火门为( )。",[57,59,61,63],{"key":20,"text":58,"correct":29},"甲级",{"key":24,"text":60,"correct":22},"乙级",{"key":27,"text":62,"correct":22},"丙级",{"key":31,"text":64,"correct":22},"乙级或丙级",{"id":66,"libraryId":5,"type":15,"typeLabel":16,"stem":67,"options":68,"answer":20,"analysis":33},881155,"洁净厂房的耐火等级( )。",[69,71,73,75],{"key":20,"text":70,"correct":29},"不应低于二级",{"key":24,"text":72,"correct":22},"不应低于一级",{"key":27,"text":74,"correct":22},"三级",{"key":31,"text":76,"correct":22},"四级",{"id":78,"libraryId":5,"type":15,"typeLabel":16,"stem":79,"options":80,"answer":27,"analysis":33},881156,"大中型活塞式制冷压缩机采用( )的方法调节冷量。",[81,83,85,87],{"key":20,"text":82,"correct":22},"变频调节",{"key":24,"text":84,"correct":22},"压缩机停、开",{"key":27,"text":86,"correct":29},"预开部分气缸的吸气阀片",{"key":31,"text":88,"correct":22},"滑阀调节",{"id":90,"libraryId":5,"type":15,"typeLabel":16,"stem":91,"options":92,"answer":24,"analysis":33},881157,"下列哪项不是水蓄冷系统的特点( )。",[93,95,97,99],{"key":20,"text":94,"correct":22},"使用常规空调冷水机组",{"key":24,"text":96,"correct":29},"只使用专门建设的蓄水池",{"key":27,"text":98,"correct":22},"冷损耗较大",{"key":31,"text":100,"correct":22},"技术要求低",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":24,"analysis":33},881158,"室内供暖系统金属立管管卡安装，不符合要求的是( )。",[105,107,109,111],{"key":20,"text":106,"correct":22},"楼层高度为5m时，每层安装1个管卡",{"key":24,"text":108,"correct":29},"楼层高度为6m时，每层安装1个管卡",{"key":27,"text":110,"correct":22},"管卡安装高度距地面1.5m",{"key":31,"text":112,"correct":22},"同一房间管卡应安装在同一高度上",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":115,"options":116,"answer":31,"analysis":33},881159,"绿色建筑作为优选项加分，要求供暖或空调能耗( )。",[117,119,121,123],{"key":20,"text":118,"correct":22},"满足本气候区国家建筑节能标准规定的能耗指标",{"key":24,"text":120,"correct":22},"小于本气候区国家建筑节能标准规定的能耗指标的95%",{"key":27,"text":122,"correct":22},"小于本气候区国家建筑节能标准规定的能耗指标的90%",{"key":31,"text":124,"correct":29},"小于本气候区国家建筑节能标准规定的能耗指标的80%",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":27,"analysis":33},881160,"在软水器从城市生活饮用水管道连接的进水管上，应设( )。",[129,131,133,135],{"key":20,"text":130,"correct":22},"止回阀",{"key":24,"text":132,"correct":22},"检修阀门",{"key":27,"text":134,"correct":29},"管道倒流防止器",{"key":31,"text":136,"correct":22},"减压阀",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":31,"analysis":33},881161,"下列哪一项蒸汽供暖系统中疏水器作用的说法是正确的？( )",[141,143,145,147],{"key":20,"text":142,"correct":22},"排出用热设备及管道中的凝结水，阻止蒸汽和空气通过",{"key":24,"text":144,"correct":22},"排出用热设备及管道中的蒸汽和空气，阻止凝结水通过",{"key":27,"text":146,"correct":22},"排出用热设备及管道中的空气，阻止蒸汽和凝结水通过",{"key":31,"text":148,"correct":29},"排出用热设备及管道中的凝结水和空气，阻止蒸汽通过",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":31,"analysis":33},881162,"下列哪一项因素与确定给水管道的流速无关？( )",[153,155,157,159],{"key":20,"text":154,"correct":22},"管道直径",{"key":24,"text":156,"correct":22},"给水管网的工作压力",{"key":27,"text":158,"correct":22},"防止水流噪声的要求",{"key":31,"text":160,"correct":29},"管道流量",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":31,"analysis":33},881163,"蒸汽供热管网水力计算时，下列哪个说法是错误的？( )",[165,166,168,170],{"key":20,"text":33,"correct":22},{"key":24,"text":167,"correct":22},"饱和蒸汽在DN≤200mm管道内的流速不得大于35m\u002Fs",{"key":27,"text":169,"correct":22},"局部阻力与沿程阻力的比值根据管径、补偿器类型、管线类型选取",{"key":31,"text":171,"correct":29},"蒸汽密度变化不大，可不必对密度的变化予以修正计算",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":24,"analysis":33},881164,"单跨热车间自然通风进、排风窗(局部阻力系数相等)面积与中和面位置，下列哪一项为正确？",[176,178,180,182],{"key":20,"text":177,"correct":22},"进风窗面积越大，中和面越靠近排风口",{"key":24,"text":179,"correct":29},"进风窗面积越大，中和面越靠近进风口",{"key":27,"text":181,"correct":22},"排风口面积越大，中和面越靠近进风口",{"key":31,"text":183,"correct":22},"进、排风口增加同样的面积，中和面位置不变",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":31,"analysis":33},881165,"建筑室内给水系统为使用和检修要求应设置阀门，下列哪一项是错误的？",[188,190,192,194],{"key":20,"text":189,"correct":22},"入户管起始端",{"key":24,"text":191,"correct":22},"各种设备的配水管上",{"key":27,"text":193,"correct":22},"各立管的起始端",{"key":31,"text":195,"correct":29},"配水点大于等于8个的配水支管上",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":24,"analysis":33},881166,"多层公共建筑中长度大于( )的内走道应设排烟设施。",[200,202,204,206],{"key":20,"text":201,"correct":22},"10m",{"key":24,"text":203,"correct":29},"20m",{"key":27,"text":205,"correct":22},"30m",{"key":31,"text":207,"correct":22},"40m",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":27,"analysis":33},881167,"多层建筑中的排烟管道与可燃物保持的最小距离为( )。",[212,214,216,218],{"key":20,"text":213,"correct":22},"50mm",{"key":24,"text":215,"correct":22},"100mm",{"key":27,"text":217,"correct":29},"150mm",{"key":31,"text":219,"correct":22},"200mm",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":27,"analysis":33},881168,"有消声要求的通风与空调系统，室内允许噪声级为35～50dB (A)时，主风管风速应为( )m\u002Fs。",[224,226,228,230],{"key":20,"text":225,"correct":22},"2～4",{"key":24,"text":227,"correct":22},"3～5",{"key":27,"text":229,"correct":29},"4～7",{"key":31,"text":231,"correct":22},"6～9",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":24,"analysis":33},881169,"地源热泵系统涵盖的范围为( )。",[236,238,240,242],{"key":20,"text":237,"correct":22},"地埋管热泵、地下水热泵、地表水热泵和地热水热泵系统",{"key":24,"text":239,"correct":29},"地埋管热泵、地下水热泵和地表水热泵系统",{"key":27,"text":241,"correct":22},"地埋管热泵、地下水热泵、地表水热泵和污水源热泵系统",{"key":31,"text":243,"correct":22},"地埋管热泵、地下水热泵、地表水热泵和水环系统",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":31,"analysis":33},881170,"选择通风机时，下列哪一项是错误的？( )",[248,250,252,254],{"key":20,"text":249,"correct":22},"定转速通风机的压力应在系统压力损失上附加10%～15%",{"key":24,"text":251,"correct":22},"通风机的工况效率不应低于通风机最高效率的90%",{"key":27,"text":253,"correct":22},"变频通风机压力应以系统计算的总压力损失作为额定风压",{"key":31,"text":255,"correct":29},"通风机的风量应附加风管和设备的漏风量，但正压除尘系统计入除尘器的漏风量",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":27,"analysis":33},881171,"按《京都议定书》规定，下列制冷剂中，( )不属于温室气体。",[260,261,263,265],{"key":20,"text":33,"correct":22},{"key":24,"text":262,"correct":22},"HFC",{"key":27,"text":264,"correct":29},"氨",{"key":31,"text":266,"correct":22},"丙烷",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":27,"analysis":33},881172,"热水供暖系统3台同型号循环水泵并联运行，若1台水泵停止运行，其他2台水泵的流量和扬程会如何变化？( )",[271,273,275,277],{"key":20,"text":272,"correct":22},"流量减小，扬程增大",{"key":24,"text":274,"correct":22},"流量和扬程均减小",{"key":27,"text":276,"correct":29},"流量增大，扬程减小",{"key":31,"text":278,"correct":22},"流量和扬程均增大",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":27,"analysis":33},881173,"下列提高空调冷水机组综合部分负荷性能的措施中，最有效的措施是( )。",[283,285,287,289],{"key":20,"text":284,"correct":22},"提高100%负荷时的性能系数",{"key":24,"text":286,"correct":22},"提高75%负荷时的性能系数",{"key":27,"text":288,"correct":29},"提高50%负荷时的性能系数",{"key":31,"text":290,"correct":22},"提高25%负荷时的性能系数",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":24,"analysis":33},881174,"在设计供暖系统时，正确布置散热设备与选择附件的做法是( )。",[295,297,299,301],{"key":20,"text":296,"correct":22},"采用活塞式减压阀，减压后的压力0.08MPa",{"key":24,"text":298,"correct":29},"某蒸汽系统的安全阀通向室外的排气管管径为4.5cm",{"key":27,"text":300,"correct":22},"为了缓冲空气直接进入室内，在门斗处设置散热器",{"key":31,"text":302,"correct":22},"采用气压罐定压时，系统补水量可取总容水量的2%",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":20,"analysis":33},881175,"商业建筑用天然气的设备设置在地下室、半地下室和地上密闭房间时，规定房间不工作时换气次数不应小于( )。",[307,308,309,310],{"key":20,"text":33,"correct":29},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":31,"analysis":33},881176,"用毕托管与倾斜式微压计测定管道内气体流动参数，下列哪一项不能直接读得结果？",[315,317,319,321],{"key":20,"text":316,"correct":22},"全压",{"key":24,"text":318,"correct":22},"静压",{"key":27,"text":320,"correct":22},"动压",{"key":31,"text":322,"correct":29},"流量",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":24,"analysis":33},881177,"某住宅小区道路的浇洒面积为1200㎡，设计浇洒用水量符合规范规定的应是( )。",[327,329,331,333],{"key":20,"text":328,"correct":22},"2000L\u002Fd",{"key":24,"text":330,"correct":29},"3000L\u002Fd",{"key":27,"text":332,"correct":22},"4000L\u002Fd",{"key":31,"text":334,"correct":22},"5000L\u002Fd",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":24,"analysis":33},881178,"孔板送风方式孔板上部稳压层应计算确定，但净高不应小于( )。",[339,341,343,345],{"key":20,"text":340,"correct":22},"0.1m",{"key":24,"text":342,"correct":29},"0.2m",{"key":27,"text":344,"correct":22},"0.3m",{"key":31,"text":346,"correct":22},"没有规定",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":24,"analysis":33},881179,"下列关于空调冷、热水管道绝热层厚度的计算方法，哪一项是错误的?( )。",[351,353,355,357],{"key":20,"text":352,"correct":22},"空调水系统采用四管制时，供热管道采用经济厚度方法计算",{"key":24,"text":354,"correct":29},"空调水系统采用四管制时，供冷管道采用防结露方法计算",{"key":27,"text":356,"correct":22},"空调水系统采用两管制时，水系统管道分别按冷管道与热管道计算方法计算绝热层厚度，并取二者的较大值",{"key":31,"text":358,"correct":22},"空调凝结水管道采用防止结露方法计算",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":27,"analysis":33},881180,"低温热水地面辐射采暖系统的工作压力，应是下列哪一项？",[363,365,367,369],{"key":20,"text":364,"correct":22},"≤0.4MPa",{"key":24,"text":366,"correct":22},"≤0.6MPa",{"key":27,"text":368,"correct":29},"≤0.8MPa",{"key":31,"text":370,"correct":22},"≤1.0MPa",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":31,"analysis":33},881181,"地源热泵的地理管系统的水压试验次数为下列哪一项？",[375,377,379,381],{"key":20,"text":376,"correct":22},"1次",{"key":24,"text":378,"correct":22},"2次",{"key":27,"text":380,"correct":22},"3次",{"key":31,"text":382,"correct":29},"4次",{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":24,"analysis":33},881182,"某25层的办公建筑，有一靠外墙的防烟楼梯间，该防烟楼梯间共有25个1.5m×2.1m的通向前室的双扇防火门和20个1.5m×1.6m的外窗。该防烟楼梯间及前室设置防烟措施正确，且投资较少的应是下列何项?( )。",[387,389,391,393],{"key":20,"text":388,"correct":22},"仅对该楼梯间加压送风",{"key":24,"text":390,"correct":29},"仅对该楼梯间前室加压送风",{"key":27,"text":392,"correct":22},"该楼梯间和前室均应加压送风",{"key":31,"text":394,"correct":22},"该楼梯间和前室均不设加压送风",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":24,"analysis":33},881183,"以下哪种材料不应作为洁净室金属壁板的夹芯材料?( )。",[399,401,403,405],{"key":20,"text":400,"correct":22},"矿棉板",{"key":24,"text":402,"correct":29},"聚苯板",{"key":27,"text":404,"correct":22},"岩棉板",{"key":31,"text":406,"correct":22},"以上皆是",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":31,"analysis":33},881184,"某食品车间长40m、宽10m、层高6m，车间内生产(含电热)设备总功率为215kW，有150名操作工，身着薄棉质工作服坐在流水线旁操作，设计采用全面造风形式消除室内余热并对进风进行两级净化处理(初效和中效过滤)。具体为：采用无冷源的全空气低速送风系统(5台60000m3\u002Fh机组送风，沿车间长度方向布置的送风管设在4m标高处，屋顶设有10台23795m3\u002Fh的排风机进行排风)，气流组织为单侧送(送风速度为2.5m\u002Fs)，顶部排风。车间曾发生多例工人中暑(该地区夏季通风温度为31.2℃)，造成中暑的首选原因应是下列哪一项？",[411,413,415,417],{"key":20,"text":412,"correct":22},"新风量不够",{"key":24,"text":414,"correct":22},"排风量不够",{"key":27,"text":416,"correct":22},"送风量与排风量不匹配",{"key":31,"text":418,"correct":29},"气流组织不正确",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":24,"analysis":33},881185,"关于SX26-1742溴化锂冷水机组的表述，正确的是下列何项?( )。",[423,425,427,429],{"key":20,"text":424,"correct":22},"单效型，蒸汽压力0.6MPa，名义制冷量1740kW，冷水出水温度7℃",{"key":24,"text":426,"correct":29},"双效型，蒸汽压力0.6MPa，名义制冷量1740kW，冷水出水温度10℃",{"key":27,"text":428,"correct":22},"双效型，蒸汽压力0.6MPa，加热热源1740kg\u002Fh，冷水出水温度10℃",{"key":31,"text":430,"correct":22},"双效型，蒸汽压力0.6MPa，加热热源1740kg\u002Fh，冷水出水温度7℃",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":20,"analysis":33},881186,"空调水系统的实际流量比额定流量(最佳状态点)大20%，分别采用节流调节和变频调节方法将系统流量调到额定流量，正确的是( )。",[435,437,439,441],{"key":20,"text":436,"correct":29},"节流调节的水泵运行效率通常高于变频调节方式",{"key":24,"text":438,"correct":22},"节流调节的水泵功耗通常低于变频调节方式",{"key":27,"text":440,"correct":22},"变频调节时水泵扬程不变",{"key":31,"text":442,"correct":22},"节流调节会使水泵能耗增加",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":27,"analysis":33},881187,"在对某建筑工程进行机械防烟系统设计时，若以“++”、“+”、“-”表示？位静压由大到小的顺序，其压力控制不正确的是下列哪一项？",[447,449,451,453],{"key":20,"text":448,"correct":22},"对防烟楼梯间及其前室分别加压送风时，楼梯间“++”，前室“+”",{"key":24,"text":450,"correct":22},"前室和合用前室加压送风时，前室“+”。走廊“-”",{"key":27,"text":452,"correct":29},"防烟楼梯间及其前室分别加压送风时，楼梯间“+”，合用前室“++”",{"key":31,"text":454,"correct":22},"防烟楼梯间及其消防电梯间的合用前室分别加压送风时，楼梯间“++”，前室“+”，走廊“-”",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":27,"analysis":33},881188,"异程式热水供暖系统的水平失调是由下列哪个原因造成的？( )",[459,461,463,465],{"key":20,"text":460,"correct":22},"热压作用",{"key":24,"text":462,"correct":22},"自然循环作用压力不同",{"key":27,"text":464,"correct":29},"并联环路的阻力相差较大",{"key":31,"text":466,"correct":22},"散热器在立管中的连接方式不同",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":20,"analysis":33},881189,"对于地上建筑层数为30层的高层建筑，其排水系统设有专用通气立管时，专用通气立管的管径应( )。",[471,473,475,477],{"key":20,"text":472,"correct":29},"与排水立管管径相同",{"key":24,"text":474,"correct":22},"等于DN100",{"key":27,"text":476,"correct":22},"等于DN75",{"key":31,"text":478,"correct":22},"等于DN50",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":24,"analysis":33},881190,"敷设于某高层建筑竖井中的燃气立管，做法符合要求的应为下列哪一项",[483,485,487,489],{"key":20,"text":484,"correct":22},"竖井内燃气管道的最高工作压力可为0.4MPa",{"key":24,"text":486,"correct":29},"与上下水、热力管道共用竖井",{"key":27,"text":488,"correct":22},"竖井每隔4层设置防火分隔",{"key":31,"text":490,"correct":22},"竖井每隔6层设置一燃气浓度检测报警器",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":27,"analysis":33},881191,"洁净室空调系统设计中，对于过滤器的安装位置，下列哪一项做法是错误的？( )",[495,497,499,501],{"key":20,"text":496,"correct":22},"超高效过滤器必须设置在净化空调系统的末端",{"key":24,"text":498,"correct":22},"高效过滤器作为末端过滤器时，宜设置在净化空调系统的末端",{"key":27,"text":500,"correct":29},"中效过滤器宜集中设置在净化空调系统的负压端",{"key":31,"text":502,"correct":22},"粗效过滤器可设置在净化空调系统的负压端",{"id":504,"libraryId":5,"type":505,"typeLabel":506,"stem":507,"options":508,"answer":517,"analysis":33},881192,2,"多选题","关于压力测试点，下列说法正确的是( )。",[509,511,513,515],{"key":20,"text":510,"correct":29},"圆形风道在同一断面设置两个彼此垂直的测孔，并将管道断面分成一定数量的等面积同心环，布置测点",{"key":24,"text":512,"correct":29},"矩形风道可将风道断面划分为若干等面积的小矩形，测点布置在每个小矩形的中心",{"key":27,"text":514,"correct":29},"矩形风道划分的小矩形每边的长度为200.mm左右",{"key":31,"text":516,"correct":29},"无论是圆形风道还是矩形风道，测点越多，测量精度越高","ABCD",{"id":519,"libraryId":5,"type":505,"typeLabel":506,"stem":520,"options":521,"answer":530,"analysis":33},881193,"供暖系统管道的弯曲半径应为( )。",[522,524,526,528],{"key":20,"text":523,"correct":22},"钢制焊接弯头，不小于外径的3倍",{"key":24,"text":525,"correct":29},"钢管热煨弯，不小于外径的3.5倍",{"key":27,"text":527,"correct":29},"钢管冷煨弯，不小于外径的4倍",{"key":31,"text":529,"correct":22},"钢制冲压弯头，不小于外径的1.5倍","BC",{"id":532,"libraryId":5,"type":505,"typeLabel":506,"stem":533,"options":534,"answer":543,"analysis":33},881194,"关于热泵机组和系统的说法，下列哪几项是错误的？( )",[535,537,539,541],{"key":20,"text":536,"correct":29},"空气源热泵系统由于从空气中取热，其系统的EER一定低于地下水地源热泵系统",{"key":24,"text":538,"correct":29},"地埋管地源热泵系统间歇供热时的能效系数小于连续供热方式",{"key":27,"text":540,"correct":22},"利用湖水的水源热泵系统，利用PE管与湖水间接换热，可以解决湖水水质对水源热泵机组的影响",{"key":31,"text":542,"correct":22},"污水源热泵机组供热时，如果取用的是生活污水处理前的热量，则应综合污水处理的用能变化判定其是否节能","AB",{"id":545,"libraryId":5,"type":505,"typeLabel":506,"stem":546,"options":547,"answer":530,"analysis":33},881195,"在地面辐射采暖系统中，使用发泡水泥[导热系数为0.09W\u002F(m.K)]代替聚苯乙烯泡沫板[导热系数≤0.04IW\u002F(m3K)]作为楼层间楼板的绝热层时，其合理的厚度约为下列哪几项？",[548,550,552,554],{"key":20,"text":549,"correct":22},"90～80mm",{"key":24,"text":551,"correct":29},"66mm",{"key":27,"text":553,"correct":29},"44mm",{"key":31,"text":555,"correct":22},"30～20mm",{"id":557,"libraryId":5,"type":505,"typeLabel":506,"stem":558,"options":559,"answer":568,"analysis":33},881196,"对于冷库制冷系统中的中间冷却器，必须与自动控制系统相关联的保护装置是( )。",[560,562,564,566],{"key":20,"text":561,"correct":29},"超高液位报警器",{"key":24,"text":563,"correct":22},"超高压报警器",{"key":27,"text":565,"correct":29},"正常液位控制",{"key":31,"text":567,"correct":22},"正常压力控制","AC",{"id":570,"libraryId":5,"type":505,"typeLabel":506,"stem":571,"options":572,"answer":581,"analysis":33},881197,"关于室内燃气引入管的设置，下列说法正确的是( )。",[573,575,577,579],{"key":20,"text":574,"correct":22},"进入密闭房间时，应设置换气口，通风换气次数不应小于5次\u002Fh",{"key":24,"text":576,"correct":29},"应设在厨房或走廊等便于检修的非居住房间内",{"key":27,"text":578,"correct":29},"穿过建筑物基础、墙或管沟时，均应设置在套管中",{"key":31,"text":580,"correct":29},"应设置阀门，且宜设置在室内","BCD",{"id":583,"libraryId":5,"type":505,"typeLabel":506,"stem":584,"options":585,"answer":581,"analysis":33},881198,"某夏热冬暖地区的7层住宅，按照节能设计标准的规定，在下列哪些情况下，应采用“对比评定法”对其节能设计进行综合评价？( )",[586,588,590,592],{"key":20,"text":587,"correct":22},"建筑物的体形系数为0.45",{"key":24,"text":589,"correct":29},"南向窗墙面积比为0.55",{"key":27,"text":591,"correct":29},"全部采用传热系数为3.2W\u002F(㎡·K)的外窗",{"key":31,"text":593,"correct":29},"外墙的热惰性指标2.5，传热系数1.2W\u002F(㎡·K)；屋顶的热惰性指标3.0，传热系数0.9W\u002F(㎡·K)",{"id":595,"libraryId":5,"type":505,"typeLabel":506,"stem":596,"options":597,"answer":517,"analysis":33},881199,"库房耗冷量计算需要的参数有( )。",[598,600,602,604],{"key":20,"text":599,"correct":29},"夏季空气调节日平均温度",{"key":24,"text":601,"correct":29},"夏季通风温度",{"key":27,"text":603,"correct":29},"夏季通风室外计算相对湿度",{"key":31,"text":605,"correct":29},"各冷间的温度、湿度",{"id":607,"libraryId":5,"type":505,"typeLabel":506,"stem":608,"options":609,"answer":618,"analysis":33},881200,"关于冬季的空气处理过程，下列说法正确的是( )。",[610,612,614,616],{"key":20,"text":611,"correct":29},"一次回风系统冬季的空气处理过程有绝热加温和等温加湿两种处理方式",{"key":24,"text":613,"correct":29},"一次回风系统两种处理方式实际消耗的热量是相同的",{"key":27,"text":615,"correct":29},"二次回风系统冬季消耗的数量与一次回风系统相同",{"key":31,"text":617,"correct":22},"二次回风系统在冬季具有节能效果","ABC",[620,623,626,629,632,635],{"id":15,"name":621,"category":7,"favorite":622},"领导干部任职前廉政法规知识测试题",92,{"id":624,"name":625,"category":7,"favorite":15},595,"建筑结构与设备",{"id":627,"name":628,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":630,"name":631,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":633,"name":634,"category":7,"favorite":8},534,"BIM工程师",{"id":636,"name":634,"category":7,"favorite":8},535]