[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-26":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":607},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,26,50,2054,[13,33,45,57,69,81,93,105,117,129,141,153,165,177,185,197,209,221,229,241,253,265,277,289,301,313,325,337,349,361,373,385,397,409,421,433,445,457,469,481,493,505,516,527,539,551,563,575,587,595],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":17},881101,1,"单选题","",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","新风系统用了中效过滤器",false,{"key":24,"text":25,"correct":22},"B","新风送风道过长",{"key":27,"text":28,"correct":29},"C","室内未设置排风系统",true,{"key":31,"text":32,"correct":22},"D","室外气温过高",{"id":34,"libraryId":5,"type":15,"typeLabel":16,"stem":35,"options":36,"answer":31,"analysis":17},881102,"对于末端温度可控的空调系统，下列计算空调系统冷负荷的方法中正确的是( )。",[37,39,41,43],{"key":20,"text":38,"correct":22},"各房间空调冷负荷最大值相加",{"key":24,"text":40,"correct":22},"各房间空调冷负荷最大值相加乘以一个大于1的安全系数",{"key":27,"text":42,"correct":22},"各房间逐时空调冷负荷的综合最大值",{"key":31,"text":44,"correct":29},"各房间逐时空调冷负荷的综合最大值乘以一个小于1的系数",{"id":46,"libraryId":5,"type":15,"typeLabel":16,"stem":47,"options":48,"answer":31,"analysis":17},881103,"集中生活热水供应系统的第一循环管网是指( )。",[49,51,53,55],{"key":20,"text":50,"correct":22},"热源一次热媒的循环",{"key":24,"text":52,"correct":22},"生活热水供应系统的配水管网",{"key":27,"text":54,"correct":22},"生活热水供应系统的回水管网",{"key":31,"text":56,"correct":29},"热水机组与贮热水罐之间的循环",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":27,"analysis":17},881104,"空气密度发生变化，风机送风体积流量( )。",[61,63,65,67],{"key":20,"text":62,"correct":22},"变大",{"key":24,"text":64,"correct":22},"变小",{"key":27,"text":66,"correct":29},"不变",{"key":31,"text":68,"correct":22},"不确定",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":20,"analysis":17},881105,"某热水供暖系统有5个供暖热用户，若关闭其中任何1个用户，则下列哪个说法是错误的？( )",[73,75,77,79],{"key":20,"text":74,"correct":29},"其他4个用户的流量按同一比例变化",{"key":24,"text":76,"correct":22},"其他4个用户流量均增加",{"key":27,"text":78,"correct":22},"系统的总阻力数增大，总流量减小",{"key":31,"text":80,"correct":22},"其他4个用户的室温均升高",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":27,"analysis":17},881106,"在相同建筑条件下采用热风供暖和散热器供暖，关于建筑围护结构总计算耗热量，下列哪一项是正确的？( )",[85,87,89,91],{"key":20,"text":86,"correct":22},"热风供暖比散热器供暖大",{"key":24,"text":88,"correct":22},"热风供暖比散热器供暖小",{"key":27,"text":90,"correct":29},"两者的围护结构总耗热量相等",{"key":31,"text":92,"correct":22},"两者无法比较",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":31,"analysis":17},881107,"下述有关有效热量系数的说法，哪一项是错误的？",[97,99,101,103],{"key":20,"text":98,"correct":22},"热源的高度增加，有效热量系数数值减小",{"key":24,"text":100,"correct":22},"热源的辐射成分占总散热量百分比增加，有效热量系数数值加大",{"key":27,"text":102,"correct":22},"热源的占地面积与房间的面积之比增加，有效热量系数数值加大",{"key":31,"text":104,"correct":29},"有效热量系数越大反映热源总散热量散入房间的热量越大",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":27,"analysis":17},881108,"位于洁净室内风管与管道的绝热材料可采用下列哪一项？",[109,111,113,115],{"key":20,"text":110,"correct":22},"玻璃棉",{"key":24,"text":112,"correct":22},"岩棉",{"key":27,"text":114,"correct":29},"闭孔橡塑泡沫",{"key":31,"text":116,"correct":22},"硅酸铝棉",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":27,"analysis":17},881109,"高压蒸汽系统最不利环路供汽管的压力损失不应大于系统起始压力的( )。",[121,123,125,127],{"key":20,"text":122,"correct":22},"10%",{"key":24,"text":124,"correct":22},"20%",{"key":27,"text":126,"correct":29},"25%",{"key":31,"text":128,"correct":22},"30%",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":24,"analysis":17},881110,"关于地板送风空调方案的说法中，不正确的是( )。",[133,135,137,139],{"key":20,"text":134,"correct":22},"地板送风方式的送风温差较小、风量增加，因此其风系统的能耗有可能增加",{"key":24,"text":136,"correct":29},"地板送风方式直接将新鲜空气送入人员工作区，因此空气质量较好",{"key":27,"text":138,"correct":22},"地板送风方式比较适用于层高较高的情况",{"key":31,"text":140,"correct":22},"地板送风的送风速度较小，因此送风口面积较大",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":24,"analysis":17},881111,"变风量空调系统的主要特点是下列哪一项？( )",[145,147,149,151],{"key":20,"text":146,"correct":22},"可分区进行温湿度控制、减小空调机组容量、运行节能、维护工作量小",{"key":24,"text":148,"correct":29},"可分区进行温度控制、减小空调机组容量、运行节能、房间分隔灵活",{"key":27,"text":150,"correct":22},"可分区进行温度控制、减小空调机组容量、降低初投资、运行节能",{"key":31,"text":152,"correct":22},"可分区进行温湿度控制、减少空调机组容量、运行节能、房间分隔灵活",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":27,"analysis":17},881112,"在采暖房间内有明设的不保温管道时，应( )。",[157,159,161,163],{"key":20,"text":158,"correct":22},"作为获得的热量从房间采暖负荷中扣除",{"key":24,"text":160,"correct":22},"按照管道的全部散热量，折减散热器的数量",{"key":27,"text":162,"correct":29},"按照管道所在不同部位计算的散热量，折减散热器的数量",{"key":31,"text":164,"correct":22},"计算热媒在管道中的冷却情况，增加散热器的数量",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":31,"analysis":17},881113,"使用温度低于-20℃的燃气管道，其材质选择正确的应为( )。",[169,171,173,175],{"key":20,"text":170,"correct":22},"焊接钢管",{"key":24,"text":172,"correct":22},"无缝钢管",{"key":27,"text":174,"correct":22},"不锈钢管",{"key":31,"text":176,"correct":29},"奥氏体不锈钢管",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":27,"analysis":17},881114,"某3层建筑，热回收型换气机的新风进风口、排风口布置方式最合理的应是下列哪一项？( )",[181,182,183,184],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":22},{"key":27,"text":17,"correct":29},{"key":31,"text":17,"correct":22},{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":27,"analysis":17},881115,"氨制冷系统中，润滑油( )。",[189,191,193,195],{"key":20,"text":190,"correct":22},"与氨互溶",{"key":24,"text":192,"correct":22},"高温时溶解度大，低温时溶解度小",{"key":27,"text":194,"correct":29},"与氨几乎不溶",{"key":31,"text":196,"correct":22},"密度小，浮于氨液之上",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":27,"analysis":17},881116,"为了节水，中水系统中水处理的水源应选用下列哪一项？( )",[201,203,205,207],{"key":20,"text":202,"correct":22},"生活污水",{"key":24,"text":204,"correct":22},"饮食业厨房排水",{"key":27,"text":206,"correct":29},"生活洗涤排水",{"key":31,"text":208,"correct":22},"空调冷凝水",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":24,"analysis":17},881117,"高层民用建筑中庭的高度超过( )时，规范规定为不应采用自然排烟。",[213,215,217,219],{"key":20,"text":214,"correct":22},"10m",{"key":24,"text":216,"correct":29},"12m",{"key":27,"text":218,"correct":22},"15m",{"key":31,"text":220,"correct":22},"不限制",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":24,"analysis":17},881118,"民用建筑的地下室、半地下室、设备层和地上密闭房间敷设燃气管道时房间的事故排风换气次数应不小于( )。",[225,226,227,228],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":29},{"key":27,"text":17,"correct":22},{"key":31,"text":17,"correct":22},{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":31,"analysis":17},881119,"暗埋的用户燃气管道的设计使用年限，应为下列哪一项？",[233,235,237,239],{"key":20,"text":234,"correct":22},"不应小于20年",{"key":24,"text":236,"correct":22},"不应小于30年",{"key":27,"text":238,"correct":22},"不应小于40年",{"key":31,"text":240,"correct":29},"不应小于50年",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":31,"analysis":17},881120,"对于一台给定的制冷压缩机，在运行过程中冷凝温度保持一致，蒸发温度逐渐下降，请问制冷量和耗功率的变化′，下列哪一项是正确的？( )",[245,247,249,251],{"key":20,"text":246,"correct":22},"制冷量增大，耗功率增大",{"key":24,"text":248,"correct":22},"制冷量减小，耗功率减小",{"key":27,"text":250,"correct":22},"制冷量增大，耗功率逐渐减小",{"key":31,"text":252,"correct":29},"制冷量减小，耗功率先增大后减小",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":20,"analysis":17},881121,"沉降室属于( )除尘器。",[257,259,261,263],{"key":20,"text":258,"correct":29},"湿式重力",{"key":24,"text":260,"correct":22},"干式重力",{"key":27,"text":262,"correct":22},"惯性力",{"key":31,"text":264,"correct":22},"离心式",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":27,"analysis":17},881122,"按中国标准， A、 B、C类高效空气过滤器的测试，应采用下列哪一种方法？",[269,271,273,275],{"key":20,"text":270,"correct":22},"DOP法",{"key":24,"text":272,"correct":22},"油雾法",{"key":27,"text":274,"correct":29},"钠焰法",{"key":31,"text":276,"correct":22},"大气尘法",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":24,"analysis":17},881123,"高静压风机盘管机组额定风量试验工况符合国家标准的应是下列哪一项？( )",[281,283,285,287],{"key":20,"text":282,"correct":22},"风机转速高挡，带风口和过滤器，供水",{"key":24,"text":284,"correct":29},"风机转速高挡，不带风口和过滤器，不供水",{"key":27,"text":286,"correct":22},"风机转速中挡，不带风口和过滤器，不供水",{"key":31,"text":288,"correct":22},"风机转速中挡，带风口和过滤器，供水",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":31,"analysis":17},881124,"下列局部排风罩可能不需机械动力源的是( )。",[293,295,297,299],{"key":20,"text":294,"correct":22},"密闭罩",{"key":24,"text":296,"correct":22},"柜式排风罩",{"key":27,"text":298,"correct":22},"外部吸气罩",{"key":31,"text":300,"correct":29},"接受式排风罩",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":24,"analysis":17},881125,"有一高层住宅区，住宅楼均为54m高的建筑物，小区内新建锅炉房有2台SHL5.6-1.0\u002F95\u002F70-AⅡ锅炉为小区供暖，下列有关烟囱的设计，正确的是( )。",[305,307,309,311],{"key":20,"text":306,"correct":22},"设一根烟囱，烟囱高度为40m",{"key":24,"text":308,"correct":29},"设一根烟囱，烟囱高度为58m",{"key":27,"text":310,"correct":22},"设两根烟囱，烟囱高度为40m",{"key":31,"text":312,"correct":22},"设两根烟囱，烟囱高度为45m",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":20,"analysis":17},881126,"有关洁净室等级的表述，下列哪一项是正确的？",[317,319,321,323],{"key":20,"text":318,"correct":29},"100级标准是英制单位洁净度等级的表示方式",{"key":24,"text":320,"correct":22},"按照我国现行《洁净厂房设计规范》，洁净度等级数值越大，技术要求越严",{"key":27,"text":322,"correct":22},"洁净度等级是指单位容积空气中小于某规定粒径的粒子的最大数目",{"key":31,"text":324,"correct":22},"洁净室工程竣工后，在各种室内环境状态下，室内空气洁净度的测试值都应该是相同的",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":31,"analysis":17},881127,"根据《冷水机组》的规定，按名义工况制冷性能系数大小，将冷水(热泵)机组分为( )。",[329,331,333,335],{"key":20,"text":330,"correct":22},"三级，1级为能源.效率最高级，3级为合格级",{"key":24,"text":332,"correct":22},"三级，1级为合格级，3级为能源效率最高级",{"key":27,"text":334,"correct":22},"五级，1级为合格级，5级为能源效率最高级",{"key":31,"text":336,"correct":29},"五级，1级为能源效率最高级，5级为合格级",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":27,"analysis":17},881128,"低温热水地面辐射供暖系统水压试验时，做法正确的是下列哪一项？( )",[341,343,345,347],{"key":20,"text":342,"correct":22},"水压试验在分集水器冲洗后进行",{"key":24,"text":344,"correct":22},"水压试验在填充层养护期满后只进行一次",{"key":27,"text":346,"correct":29},"试验压力为工作压力的1.5倍，且不应小于0.6MPa",{"key":31,"text":348,"correct":22},"在试验压力下，稳压1h，其压力降不应大于0.06MPa",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":24,"analysis":17},881129,"变频调节的节能原因之一在于( )。",[353,355,357,359],{"key":20,"text":354,"correct":22},"属于电气调节，无机械损耗",{"key":24,"text":356,"correct":29},"无级调节，避免了启动损耗",{"key":27,"text":358,"correct":22},"降温速度快，能耗低",{"key":31,"text":360,"correct":22},"压缩机高速运转，泄漏小",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":27,"analysis":17},881130,"滚动转子式压缩机完成一个工作循环，转子旋转的角度是( )。",[365,367,369,371],{"key":20,"text":366,"correct":22},"180°",{"key":24,"text":368,"correct":22},"360°",{"key":27,"text":370,"correct":29},"720°",{"key":31,"text":372,"correct":22},"900°",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":31,"analysis":17},881131,"一栋建筑采用变风量全空气空调方案，确定空调房间最小新风量的因素中可以不考虑的是( )。",[377,379,381,383],{"key":20,"text":378,"correct":22},"人员呼吸对新风量的要求",{"key":24,"text":380,"correct":22},"维持室内正压对新风量的要求",{"key":27,"text":382,"correct":22},"稀释和排除有害气体对新风量的要求",{"key":31,"text":384,"correct":29},"排除室内的余热和余湿对新风量的要求",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":24,"analysis":17},881132,"冷库的设计规模是以( )的公称体积为计算标准。",[389,391,393,395],{"key":20,"text":390,"correct":22},"冻结间和冷藏间",{"key":24,"text":392,"correct":29},"冷藏间或冰库",{"key":27,"text":394,"correct":22},"主库所有的冷间",{"key":31,"text":396,"correct":22},"冷却间、制冰间、冻结间、冰库和冷藏间",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":24,"analysis":17},881133,"燃气锅炉房燃气系统的设计，下列做法错误的是( )。",[401,403,405,407],{"key":20,"text":402,"correct":22},"锅炉房外部引入的燃气总管上的总切断阀前应装放散管",{"key":24,"text":404,"correct":29},"燃气管道宜地下敷设",{"key":27,"text":406,"correct":22},"放散管排出口应高出锅炉房屋脊2m以上",{"key":31,"text":408,"correct":22},"吹扫气体可采用惰性气体",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":27,"analysis":17},881134,"机械排风系统在下列( )情况时，可不设机械补风系统。",[413,415,417,419],{"key":20,"text":414,"correct":22},"每天运行时间不超过3h",{"key":24,"text":416,"correct":22},"每天运行时间不超过4h",{"key":27,"text":418,"correct":29},"每天运行时间不超过2h",{"key":31,"text":420,"correct":22},"不能确定",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":31,"analysis":17},881135,"采用电能驱动的热泵供热，比直接用电能供热要节能，这是因为( )。",[425,427,429,431],{"key":20,"text":426,"correct":22},"无能量损失",{"key":24,"text":428,"correct":22},"在供热的同时，可以供冷",{"key":27,"text":430,"correct":22},"热泵的传热效率高",{"key":31,"text":432,"correct":29},"热泵的供热系数永远大于1",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":27,"analysis":17},881136,"下列关于空调冷负荷的说法中正确的是( )。",[437,439,441,443],{"key":20,"text":438,"correct":22},"空调冷负荷等于得热量",{"key":24,"text":440,"correct":22},"空调冷负荷峰值大于得热量峰值",{"key":27,"text":442,"correct":29},"空调冷负荷峰值一定小于得热量峰值",{"key":31,"text":444,"correct":22},"空调冷负荷峰值可能小于、也可能大于得热量峰值",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":24,"analysis":17},881137,"当空调房间较多，建筑物的层高较低，并且各房间要求能够独立调节时，宜采用( )空调系统。",[449,451,453,455],{"key":20,"text":450,"correct":22},"单风道定风量",{"key":24,"text":452,"correct":29},"风机盘管加新风",{"key":27,"text":454,"correct":22},"变风量",{"key":31,"text":456,"correct":22},"局部空调机组",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":27,"analysis":17},881138,"关于建筑室内消火栓设置和用水量选取的说法，正确的应是下列何项？",[461,463,465,467],{"key":20,"text":462,"correct":22},"高度超高24m的仓库消火栓的最大用水量数值为30L／s",{"key":24,"text":464,"correct":22},"某900座位的体育馆可不设置室内消火栓",{"key":27,"text":466,"correct":29},"体积为4000m3的单层商业建筑可不设置室内消火栓",{"key":31,"text":468,"correct":22},"建筑体积为12000m3的某科研楼的消火栓用水量为15L／s",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":24,"analysis":17},881139,"高层民用建筑中防烟分区规定( )是正确的。",[473,475,477,479],{"key":20,"text":474,"correct":22},"建筑面积不宜超过500㎡",{"key":24,"text":476,"correct":29},"建筑面积不宜超过500㎡且不应跨越防火分区",{"key":27,"text":478,"correct":22},"建筑面积不宜超过1000㎡且不应跨越防火分区",{"key":31,"text":480,"correct":22},"建筑面积不宜超过1000㎡",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":24,"analysis":17},881140,"某高层民用建筑物，其地上建筑为办公楼，地下建筑为汽车停车库。当设置闭式自动喷水灭火系统时，办公楼和停车库的喷水强度应分别不小于( )L／(min·㎡)。",[485,487,489,491],{"key":20,"text":486,"correct":22},"4、6",{"key":24,"text":488,"correct":29},"6、8",{"key":27,"text":490,"correct":22},"8、12",{"key":31,"text":492,"correct":22},"6、12",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":27,"analysis":17},881141,"在对冷藏库制冷系统的多项安全保护措施中，下列哪项做法是错误的？",[497,499,501,503],{"key":20,"text":498,"correct":22},"制冷剂泵设断液自动停泵装置",{"key":24,"text":500,"correct":22},"制冷剂泵排液管设止回阀",{"key":27,"text":502,"correct":29},"各种压力容器上的安全阀泄压管出口应高于周围60m内最高建筑物的屋脊5m，且应防雷、防雨水，防杂物进入",{"key":31,"text":504,"correct":22},"在氨制冷系统设紧急泄氨器",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":24,"analysis":17},881142,"下图为多联式空调(热泵)机组制冷量的测试图。问：根据产品标准进行测试时，室外机距第一个分液器(分配器)之间的冷媒管长度L，应为下列哪一项？",[509,511,513,515],{"key":20,"text":510,"correct":22},"3m",{"key":24,"text":512,"correct":29},"5m",{"key":27,"text":514,"correct":22},"8m",{"key":31,"text":214,"correct":22},{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":518,"answer":20,"analysis":17},881143,[519,521,523,525],{"key":20,"text":520,"correct":29},"用户1～4的作用压差均增大",{"key":24,"text":522,"correct":22},"供回水干管的比摩阻增大",{"key":27,"text":524,"correct":22},"供回水干管的比摩阻不变",{"key":31,"text":526,"correct":22},"用户1，2的作用压差增大，用户3，4的作用压差减小",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":27,"analysis":17},881144,"R134a不破坏臭氧层的原因是下列哪一项？( )",[531,533,535,537],{"key":20,"text":532,"correct":22},"不含氢",{"key":24,"text":534,"correct":22},"不含氟",{"key":27,"text":536,"correct":29},"不含氯",{"key":31,"text":538,"correct":22},"在大气中可分解",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":27,"analysis":17},881145,"在进行热水供暖系统水力平衡计算时，下列哪一项做法是正确的？( )",[543,545,547,549],{"key":20,"text":544,"correct":22},"机械循环双管系统自然循环压力按设计水温条件下最大循环压力计算",{"key":24,"text":546,"correct":22},"机械循环单管系统自然循环压力可忽略不计",{"key":27,"text":548,"correct":29},"各并联环路之间(不包括共同段)的压力损失相对差值不应大于15%",{"key":31,"text":550,"correct":22},"单管异程式立管的压力损失不宜小于计算环路总压力损失的50%",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":27,"analysis":17},881146,"在机械循环双管上供下回式热水供暖系统的表述中，下列哪一项是正确的？( )",[555,557,559,561],{"key":20,"text":556,"correct":22},"系统循环动力主要是重力作用力，此外还包括水泵作用力",{"key":24,"text":558,"correct":22},"系统的作用半径有限，一般总压力损失不得超过10kPa",{"key":27,"text":560,"correct":29},"由于水在各层散热器中冷却形成的重力作用力不同，一般会存在竖向失调",{"key":31,"text":562,"correct":22},"即使没有良好的调节装置，也可以放心地用于3层以上的建筑物",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":27,"analysis":17},881147,"事故通风机开关应在下列哪一个位置设置？( )",[567,569,571,573],{"key":20,"text":568,"correct":22},"在室内便于操作的地点",{"key":24,"text":570,"correct":22},"在室内",{"key":27,"text":572,"correct":29},"分别在室内外便于操作的地点",{"key":31,"text":574,"correct":22},"在室外",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":31,"analysis":17},881148,".70℃熔断(关闭)的防火阀安装在( )是正确的。",[579,581,583,585],{"key":20,"text":580,"correct":22},"穿机房的防火隔墙的风管上",{"key":24,"text":582,"correct":22},"穿防火分区防火墙的风管上",{"key":27,"text":584,"correct":22},"排烟系统风机前",{"key":31,"text":586,"correct":29},"通风空调系统风管穿防火墙(防火隔墙)、板处",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":27,"analysis":17},881149,"某车间空调系统满足的室内环境要求是：夏季t=22±1℃，p=60%±10%；冬季t=20±1℃，p=60%±10%；空气的洁净度为：IS07(即10000级)，车间长10m，宽8m，层高5m，吊顶净高3m，为保证车间的洁净度要求，风量计算时，其送风量宜选下列何项?( )。",[591,592,593,594],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":22},{"key":27,"text":17,"correct":29},{"key":31,"text":17,"correct":22},{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":27,"analysis":17},881150,"围护结构防潮验算所使用的室外计算温度应该是( )。",[599,601,603,605],{"key":20,"text":600,"correct":22},"供暖室外计算温度",{"key":24,"text":602,"correct":22},"空气调节室外计算温度",{"key":27,"text":604,"correct":29},"供暖期室外平均温度",{"key":31,"text":606,"correct":22},"根据围护结构的不同热惰性指标分别确定",[608,611,614,617,620,623],{"id":15,"name":609,"category":7,"favorite":610},"领导干部任职前廉政法规知识测试题",92,{"id":612,"name":613,"category":7,"favorite":15},595,"建筑结构与设备",{"id":615,"name":616,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":618,"name":619,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":621,"name":622,"category":7,"favorite":8},534,"BIM工程师",{"id":624,"name":622,"category":7,"favorite":8},535]