[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-25":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":617},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,25,50,2054,[13,35,47,60,74,87,100,113,125,137,145,158,171,183,195,207,219,231,243,255,267,279,291,303,315,327,339,346,358,370,382,394,406,418,430,443,456,464,476,489,501,513,525,537,549,561,569,581,593,605],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},881051,2,"多选题","在计算开式冷却水系统的补水量时应考虑( )。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","蒸发损失",true,{"key":24,"text":25,"correct":22},"B","飘逸损失",{"key":27,"text":28,"correct":29},"C","2%冷却水流量的泄漏损失",false,{"key":31,"text":32,"correct":22},"D","排污损失","ABD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":33,"analysis":34},881052,"采暖系统干管安装坡度为0.003时的应用范围的是( )。",[39,41,43,45],{"key":20,"text":40,"correct":22},"供回水管道",{"key":24,"text":42,"correct":22},"汽水同向流动管道",{"key":27,"text":44,"correct":29},"汽水逆向流动管道",{"key":31,"text":46,"correct":22},"凝结水管道",{"id":48,"libraryId":5,"type":15,"typeLabel":16,"stem":49,"options":50,"answer":59,"analysis":34},881053,"在机械通风系统中，只要涉及下列哪几种情况就不应采用循环空气？( )",[51,53,55,57],{"key":20,"text":52,"correct":22},"含有难闻气味",{"key":24,"text":54,"correct":22},"丙类厂房，如空气中含有燃烧或爆炸危险的粉尘、纤维，含尘浓度大于或等于其爆炸下限的30%时",{"key":27,"text":56,"correct":22},"局部排风系统用于排除含尘空气时，若排风经净化后，其含尘浓度仍大于或等于工作区容许浓度的30%时",{"key":31,"text":58,"correct":22},"含有甲、乙类物质的厂房","ABCD",{"id":61,"libraryId":5,"type":62,"typeLabel":63,"stem":64,"options":65,"answer":31,"analysis":34},881054,1,"单选题","某多层办公建筑，设计机械循环热水供暖系统时，合理的做法应为下列哪一项？( )",[66,68,70,72],{"key":20,"text":67,"correct":29},"水平干管必须保持与水流方向相同的坡向",{"key":24,"text":69,"correct":29},"采用同程式双管系统，作用半径控制在150m以内",{"key":27,"text":71,"correct":29},"采用同程单管跨越系统，作用半径控制在120m以内",{"key":31,"text":73,"correct":22},"采用同程单管系统，加跨越管和温控阀",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":86,"analysis":34},881055,"某9层住宅楼设计分户热计量热水采暖系统，哪些做法是错误的?( )。",[78,80,82,84],{"key":20,"text":79,"correct":22},"供暖系统的总热负荷计入向邻户传热引起的耗热量",{"key":24,"text":81,"correct":22},"计算系统供、回水干管时计入向邻户传热引起的耗热量",{"key":27,"text":83,"correct":29},"户内散热器片数计算时计入向邻户传热引起的耗热量",{"key":31,"text":85,"correct":29},"户内系统为双管系统，户内入口设置流量调节阀","AB",{"id":88,"libraryId":5,"type":15,"typeLabel":16,"stem":89,"options":90,"answer":99,"analysis":34},881056,"对照国家标准，高静压(出口静压30Pa或50Pa)风机盘管额定风量试验工况，下列哪几项是错误的？( )",[91,93,95,97],{"key":20,"text":92,"correct":29},"风机转速高挡，不带风口和过滤器，不供水",{"key":24,"text":94,"correct":22},"风机转速高挡，带风口和过滤器，供水",{"key":27,"text":96,"correct":22},"风机转速中挡，不带风口和过滤器，不供水",{"key":31,"text":98,"correct":22},"风机转速中挡，带风口和过滤器，供水","BCD",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":112,"analysis":34},881057,"限制热水地面辐射供暖系统的热水供回水温差，主要是出于( )的考虑？",[104,106,108,110],{"key":20,"text":105,"correct":22},"有利于保证地面温度的均匀",{"key":24,"text":107,"correct":29},"满足舒适要求",{"key":27,"text":109,"correct":29},"有利于延长塑料加热管的使用寿命",{"key":31,"text":111,"correct":22},"有利于保持较大的热媒流速，方便排除管内空气","AD",{"id":114,"libraryId":5,"type":62,"typeLabel":63,"stem":115,"options":116,"answer":20,"analysis":34},881058,"某工厂机械回水低压蒸汽散热器供暖系统，设计正确的是( )。",[117,119,121,123],{"key":20,"text":118,"correct":22},"凝水箱安装位置低于凝结水管",{"key":24,"text":120,"correct":29},"凝结水泵的安装位置与凝结水温度无关",{"key":27,"text":122,"correct":29},"凝结水泵入口处安装止回阀",{"key":31,"text":124,"correct":29},"散热器上部安装排气阀",{"id":126,"libraryId":5,"type":62,"typeLabel":63,"stem":127,"options":128,"answer":27,"analysis":34},881059,"下列减振措施中，不合理的是( )。",[129,131,133,135],{"key":20,"text":130,"correct":29},"转速为2900r\u002Fmin的水泵采用橡胶垫减振",{"key":24,"text":132,"correct":29},"风机进出口采用帆布软管隔振",{"key":27,"text":134,"correct":22},"转速为2900r\u002Fmin的风机采用弹簧减振器",{"key":31,"text":136,"correct":29},"水泵进出口采用金属波纹管隔振",{"id":138,"libraryId":5,"type":62,"typeLabel":63,"stem":139,"options":140,"answer":31,"analysis":34},881060,"设置在地下或地下室内的锅炉房，要求其正常换气与事故通风时的换气次数不应小于( )。",[141,142,143,144],{"key":20,"text":34,"correct":29},{"key":24,"text":34,"correct":29},{"key":27,"text":34,"correct":29},{"key":31,"text":34,"correct":22},{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":157,"analysis":34},881061,"气候补偿器是根据室外温度的变化对热力站供热进行质调节，某城市热网采用定流量运行，当室外温度高于室外设计计算温度的过程中，热网的供回水温度，供回水温差的变化表述，不符合规律的是哪几项？",[149,151,153,155],{"key":20,"text":150,"correct":22},"供水温度下降、回水温度下降、供回水温差不变",{"key":24,"text":152,"correct":29},"供水温度下降，回水温度不变，供回水温差下降",{"key":27,"text":154,"correct":22},"供水温度不变，回水温度下降，供回水温差下降",{"key":31,"text":156,"correct":29},"供水温度下降、回水温度下降、供回水温差下降","AC",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":170,"analysis":34},881062,"下列关于复合通风的描述中，正确的是( )。",[162,164,166,168],{"key":20,"text":163,"correct":22},"是自然通风和机械通风可以交替或联合运行的通风方式",{"key":24,"text":165,"correct":22},"比较适合大空间建筑及外墙具有可开启控制通风口的住宅、办公、教室等建筑",{"key":27,"text":167,"correct":22},"运行中尽量优先使用自然通风",{"key":31,"text":169,"correct":29},"只适用于民用建筑","ABC",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":33,"analysis":34},881063,"下列分层空调气流组织设计的说法中，正确的是( )。",[175,177,179,181],{"key":20,"text":176,"correct":22},"空调区宜采用双侧送风",{"key":24,"text":178,"correct":22},"空调区的跨度较小时可以采用单侧送风",{"key":27,"text":180,"correct":29},"采用单侧送风时，回风口宜设置在送风口的上方",{"key":31,"text":182,"correct":22},"采用双侧对送时，其送风射程按相对喷口中点距离的90%计算",{"id":184,"libraryId":5,"type":62,"typeLabel":63,"stem":185,"options":186,"answer":31,"analysis":34},881064,"垂直双管散热器供暖系统，对克服水在散热器和管道中冷却而产生自然作用压力造成的垂直失调，采用以下哪种技术措施有利？( )",[187,189,191,193],{"key":20,"text":188,"correct":29},"采用上供下回同程式立管系统",{"key":24,"text":190,"correct":29},"放大立管的管径",{"key":27,"text":192,"correct":29},"放大散热器支管的管径，并采用低阻力阀",{"key":31,"text":194,"correct":22},"增大散热器及支管段的阻力",{"id":196,"libraryId":5,"type":62,"typeLabel":63,"stem":197,"options":198,"answer":24,"analysis":34},881065,"某5层图书馆建筑，其自动喷水灭火系统的设计流量不应低于( )。",[199,201,203,205],{"key":20,"text":200,"correct":29},"10L\u002Fs",{"key":24,"text":202,"correct":22},"16L\u002Fs",{"key":27,"text":204,"correct":29},"20L\u002Fs",{"key":31,"text":206,"correct":29},"30L\u002Fs",{"id":208,"libraryId":5,"type":62,"typeLabel":63,"stem":209,"options":210,"answer":20,"analysis":34},881066,"一般通风系统常用的1系列离心风机的叶片基本形式，应是下列哪一项？",[211,213,215,217],{"key":20,"text":212,"correct":22},"机翼型叶片",{"key":24,"text":214,"correct":29},"径向式叶片",{"key":27,"text":216,"correct":29},"轴向式叶片",{"key":31,"text":218,"correct":29},"后向板型叶片",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":99,"analysis":34},881067,"冰蓄冷技术的特点是( )。",[223,225,227,229],{"key":20,"text":224,"correct":29},"可采用常规冷水机组",{"key":24,"text":226,"correct":22},"可实现低温送风",{"key":27,"text":228,"correct":22},"适于短时间内需要大量释冷的建筑",{"key":31,"text":230,"correct":22},"某些场合可以减少冷水机组的装机容量",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":59,"analysis":34},881068,"下列说法符合通风系统的防火防爆设计原则的有( )。",[235,237,239,241],{"key":20,"text":236,"correct":22},"含有可燃性物质的通风空气一般不能作为回风利用",{"key":24,"text":238,"correct":22},"通风气流组织要确保避免局部死角，以防可燃物质的积聚",{"key":27,"text":240,"correct":22},"在确定必要的通风量后必须核定可燃性物质的浓度。可燃性物质的浓度过大或过小都不会造成燃烧爆炸，所以应调整风量使实际浓度避开该物质的爆炸浓度范围",{"key":31,"text":242,"correct":22},"有爆炸危险的通风系统应在建筑和系统设备上考虑采用防爆和泄爆设施",{"id":244,"libraryId":5,"type":62,"typeLabel":63,"stem":245,"options":246,"answer":24,"analysis":34},881069,"某空调建筑，水系统的充水高度为80m，循环水泵置于系统最低处，扬程为32m，补水定压点在循环水泵吸入口，则补水泵的扬程至少为( )。",[247,249,251,253],{"key":20,"text":248,"correct":29},"32m",{"key":24,"text":250,"correct":22},"83m",{"key":27,"text":252,"correct":29},"80m",{"key":31,"text":254,"correct":29},"35m",{"id":256,"libraryId":5,"type":62,"typeLabel":63,"stem":257,"options":258,"answer":31,"analysis":34},881070,"年太阳辐射量大于4200MJ\u002F㎡、年极端气温不低于-45℃及日照时数大于( )的地区，宜优先采用太阳能作为热水供应热源。",[259,261,263,265],{"key":20,"text":260,"correct":29},"1100h\u002Fa",{"key":24,"text":262,"correct":29},"1200h\u002Fa",{"key":27,"text":264,"correct":29},"1300h\u002Fa",{"key":31,"text":266,"correct":22},"1400h\u002Fa",{"id":268,"libraryId":5,"type":62,"typeLabel":63,"stem":269,"options":270,"answer":24,"analysis":34},881071,"关于电子工业洁净室性能测试，下列哪一项是不正确的？",[271,273,275,277],{"key":20,"text":272,"correct":29},"6级洁净室空气洁净度等级的认证测试的最长时间间隔为1年",{"key":24,"text":274,"correct":22},"温度、相对湿度检测，应在净化空调系统至少稳定运转12h后进行",{"key":27,"text":276,"correct":29},"对于单向流洁净室风量和风速测试，其测点数不应少于5点",{"key":31,"text":278,"correct":29},"洁净度检测，每一采样点最小采样时间为1min",{"id":280,"libraryId":5,"type":62,"typeLabel":63,"stem":281,"options":282,"answer":27,"analysis":34},881072,"空调水系统补水泵设置方法中最合理的是( )。",[283,285,287,289],{"key":20,"text":284,"correct":29},"设置一台定速泵",{"key":24,"text":286,"correct":29},"设置两台定速泵，一用一备",{"key":27,"text":288,"correct":22},"设置两台定速泵，同时使用",{"key":31,"text":290,"correct":29},"设置一台变频泵，调节使用",{"id":292,"libraryId":5,"type":62,"typeLabel":63,"stem":293,"options":294,"answer":27,"analysis":34},881073,"关于人民防空地下室的通风系统设计，下列哪一项是不正确的？( )",[295,297,299,301],{"key":20,"text":296,"correct":29},"专供上部建筑使用的通风设备房间宜设置在防护密闭区之外",{"key":24,"text":298,"correct":29},"凡进入防空地下室的管道及其穿越的人防围护结构均应采取防护密闭措施",{"key":27,"text":300,"correct":22},"防空地下室的通风系统必要时可与上部建筑的通风系统合用",{"key":31,"text":302,"correct":29},"清洁进风与滤毒进风可以合用同一台进风风机",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":59,"analysis":34},881074,"进行全面通风设计时，应遵循的原则是( )。",[307,309,311,313],{"key":20,"text":308,"correct":22},"设计全面通风时，宜尽可能采用自然通风，以节约能源和投资",{"key":24,"text":310,"correct":22},"当自然通风达不到卫生或生产要求时，应采用机械通风或自然与机械联合通风",{"key":27,"text":312,"correct":22},"当散发热、蒸汽或有害物质的建筑物不能采用局部通风，或采用局部通风后达不到卫生标准要求时，应辅以全面通风或采用全面通风",{"key":31,"text":314,"correct":22},"民用建筑的厨房、厕所、浴室等宜采用自然通风或机械通风进行局部通风或全面通风",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":157,"analysis":34},881075,"关于气流组织设计的说法中，正确的是( )。",[319,321,323,325],{"key":20,"text":320,"correct":22},"夏季座椅下送风口的送风温度通常不低于19℃",{"key":24,"text":322,"correct":29},"由于孔板送风的温度均匀度好，因此应尽可能采用孔板送风方式",{"key":27,"text":324,"correct":22},"高大空间可采用喷射式送风口",{"key":31,"text":326,"correct":29},"贴附射流由于壁面摩擦阻力较大，因此射流的衰减较快，射程较短",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":157,"analysis":34},881076,"空调系统采用风机盘管加新风系统时，新风不宜经过风机盘管再送入房间，其原因有下列哪几项？( )",[331,333,335,337],{"key":20,"text":332,"correct":22},"风机盘管不运行时有可能造成新风量不足",{"key":24,"text":334,"correct":29},"风机盘管制冷能力会降低",{"key":27,"text":336,"correct":22},"会导致房间换气次数下降",{"key":31,"text":338,"correct":29},"室温不易控制",{"id":340,"libraryId":5,"type":62,"typeLabel":63,"stem":34,"options":341,"answer":20,"analysis":34},881077,[342,343,344,345],{"key":20,"text":34,"correct":22},{"key":24,"text":34,"correct":29},{"key":27,"text":34,"correct":29},{"key":31,"text":34,"correct":29},{"id":347,"libraryId":5,"type":62,"typeLabel":63,"stem":348,"options":349,"answer":31,"analysis":34},881078,"下列哪项不能保证居住空间的自然通风可开启外窗的面积满足要求？( )",[350,352,354,356],{"key":20,"text":351,"correct":29},"成都地区主卧地板面积为20㎡，可开启外窗面积为1.6㎡",{"key":24,"text":353,"correct":29},"广州地区房间地板面积为15㎡，可开启外窗面积为1.3㎡",{"key":27,"text":355,"correct":29},"北京地区房间地板面积为15㎡，可开启外窗面积为10.㎡",{"key":31,"text":357,"correct":22},"上海地区房间地板面积为18㎡，可开启外窗面积为1.4㎡",{"id":359,"libraryId":5,"type":62,"typeLabel":63,"stem":360,"options":361,"answer":31,"analysis":34},881079,"根据规范规定，燃气锅炉房的锅炉间火灾危险性分类是哪一项？",[362,364,366,368],{"key":20,"text":363,"correct":29},"属于甲类生产厂房",{"key":24,"text":365,"correct":29},"属于乙类生产厂房",{"key":27,"text":367,"correct":29},"属于丙类生产厂房",{"key":31,"text":369,"correct":22},"属于丁类生产厂房",{"id":371,"libraryId":5,"type":62,"typeLabel":63,"stem":372,"options":373,"answer":24,"analysis":34},881080,"设机械送风系统的车间，在进行冬季热平衡计算时选择空气加热器的室外空气计算温度，( )是正确的。",[374,376,378,380],{"key":20,"text":375,"correct":29},"对于局部通风系统采用冬季通风室外计算温度",{"key":24,"text":377,"correct":22},"对于消除余热、余湿及稀释低毒性有害物质的全面通风系统采用冬季通风室外计算温度",{"key":27,"text":379,"correct":29},"对于消除余热、余湿及稀释低毒性有害物质的全面通风系统采用冬季供暖室外计算温度",{"key":31,"text":381,"correct":29},"对于全面通风系统采用冬季供暖室外计算温度",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":59,"analysis":34},881081,"燃煤锅炉送风系统的阻力包括( )。",[386,388,390,392],{"key":20,"text":387,"correct":22},"空气预热器阻力",{"key":24,"text":389,"correct":22},"燃烧设备阻力",{"key":27,"text":391,"correct":22},"风道摩擦阻力",{"key":31,"text":393,"correct":22},"风道局部阻力",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":170,"analysis":34},881082,"常用的载冷剂有( )。",[398,400,402,404],{"key":20,"text":399,"correct":22},"空气、水",{"key":24,"text":401,"correct":22},"盐水溶液",{"key":27,"text":403,"correct":22},"有机化合物水溶液",{"key":31,"text":405,"correct":29},"溴化锂水溶液",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":157,"analysis":34},881083,"当集中送风热风供暖采用平行送风射流时，射流的有效作用长度与下列因素的关系中哪些是正确的？( )",[410,412,414,416],{"key":20,"text":411,"correct":22},"与送风口的安装高度成正比",{"key":24,"text":413,"correct":29},"与送风口湍流系数的大小成正比",{"key":27,"text":415,"correct":22},"与工作地带允许最大平均回流速度成正比",{"key":31,"text":417,"correct":29},"与射流末端允许最小平均回流速度成正比",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":33,"analysis":34},881084,"风机全压由( )组成。",[422,424,426,428],{"key":20,"text":423,"correct":22},"管网各种压力损失总和",{"key":24,"text":425,"correct":22},"管网进出口的压差",{"key":27,"text":427,"correct":29},"管网出口全压",{"key":31,"text":429,"correct":22},"管网出口动压",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":442,"analysis":34},881085,"对于室内产湿量一定或产湿量波动不大的情况，只要控制机器露点温度就可以控制室内相对湿度。这种通过控制机器露点来控制室内相对湿度的方法称为“间接控制法”，具体包括( )。",[434,436,438,440],{"key":20,"text":435,"correct":29},"由机器露点温度控制新风阀门",{"key":24,"text":437,"correct":22},"由机器露点温度控制新风和回风混合阀门",{"key":27,"text":439,"correct":22},"由机器露点温度控制喷水室喷水温度",{"key":31,"text":441,"correct":29},"由机器露点温度控制回风阀门","BC",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":455,"analysis":34},881086,"变频空调器比定速空调器节能的原因在于( )。",[447,449,451,453],{"key":20,"text":448,"correct":29},"属于电气调节，无机械损耗",{"key":24,"text":450,"correct":22},"无级调节，减少了启停损失",{"key":27,"text":452,"correct":29},"降温速度快，能耗低",{"key":31,"text":454,"correct":22},"压缩机低速运行时，冷凝温度降低、蒸发温度升高，改善了制冷循环","BD",{"id":457,"libraryId":5,"type":62,"typeLabel":63,"stem":458,"options":459,"answer":31,"analysis":34},881087,"描述高层住宅热压和风压共同作用下的各层相同房间冷风渗透负荷变化，下列哪个图是正确的？( )",[460,461,462,463],{"key":20,"text":34,"correct":29},{"key":24,"text":34,"correct":29},{"key":27,"text":34,"correct":29},{"key":31,"text":34,"correct":22},{"id":465,"libraryId":5,"type":62,"typeLabel":63,"stem":466,"options":467,"answer":20,"analysis":34},881088,"洁净度等级N=6的洁净室内空气中，粒径大于或等于0.5μm的悬浮粒子的最大允许浓度值为下列哪一项？",[468,470,472,474],{"key":20,"text":469,"correct":22},"35200pc\u002Fm3",{"key":24,"text":471,"correct":29},"3520pc\u002Fm3",{"key":27,"text":473,"correct":29},"1000000pc\u002Fm3",{"key":31,"text":475,"correct":29},"6pc\u002Fm3",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":488,"analysis":34},881089,"蒸汽供暖系统疏水器作用不正确的是( )。",[480,482,484,486],{"key":20,"text":481,"correct":22},"排出设备和管道中的凝水，阻止蒸汽和空气通过",{"key":24,"text":483,"correct":29},"排出设备和管道中的凝水和空气，阻止蒸汽通过",{"key":27,"text":485,"correct":22},"排出设备和管道中的蒸汽和空气，阻止凝水通过",{"key":31,"text":487,"correct":22},"排出设备和管道中的空气，阻止蒸汽和凝水通过","ACD",{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":59,"analysis":34},881090,"有顶棚的坡屋面综合传热系数与下列哪些因素有关？( )",[493,495,497,499],{"key":20,"text":494,"correct":22},"顶棚各层材料的导热系数",{"key":24,"text":496,"correct":22},"屋面与顶棚的夹角",{"key":27,"text":498,"correct":22},"顶棚凸出物的形状和尺寸",{"key":31,"text":500,"correct":22},"屋面材料的灰缝和干燥缓慢",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":488,"analysis":34},881091,"下列制冷剂中标准蒸发温度低于-20℃的是( )。",[505,507,509,511],{"key":20,"text":506,"correct":22},"R22",{"key":24,"text":508,"correct":29},"R142",{"key":27,"text":510,"correct":22},"R13",{"key":31,"text":512,"correct":22},"R12",{"id":514,"libraryId":5,"type":62,"typeLabel":63,"stem":515,"options":516,"answer":27,"analysis":34},881092,"下列对析湿系数的描述中错误的是( )。",[517,519,521,523],{"key":20,"text":518,"correct":29},"ξ越大，析出水分越多",{"key":24,"text":520,"correct":29},"ξ为进出口的比焓差与进出口显热差的比值",{"key":27,"text":522,"correct":22},"干式冷却ξ=0",{"key":31,"text":524,"correct":29},"ξ体现了盘管的除湿能力",{"id":526,"libraryId":5,"type":62,"typeLabel":63,"stem":527,"options":528,"answer":27,"analysis":34},881093,"国家标准《空气过滤器》(GB\u002FT14295-2008)规定，空气过滤器按效率和阻力性能分为( )。",[529,531,533,535],{"key":20,"text":530,"correct":29},"粗效过滤器、中效过滤器",{"key":24,"text":532,"correct":29},"粗效过滤器、中效过滤器、高中效过滤器",{"key":27,"text":534,"correct":22},"粗效过滤器、中效过滤器、高中效过滤器、亚高效过滤器",{"key":31,"text":536,"correct":29},"粗效过滤器、中效过滤器、高效过滤器",{"id":538,"libraryId":5,"type":62,"typeLabel":63,"stem":539,"options":540,"answer":27,"analysis":34},881094,"《公建节能》规定，采用水冷螺杆式冷水机组和离心式冷水机组，其限定的最低能源效率等级为( )。",[541,543,545,547],{"key":20,"text":542,"correct":29},"螺杆式冷水机组为能效等级3，离心式冷水机组为能效等级2",{"key":24,"text":544,"correct":29},"螺杆式冷水机组为能效等级4，离心式冷水机组为能效等级4",{"key":27,"text":546,"correct":22},"螺杆式冷水机组为能效等级4，离心式冷水机组为能效等级3",{"key":31,"text":548,"correct":29},"螺杆式冷水机组为能效等级3，离心式冷水机组为能效等级3",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":170,"analysis":34},881095,"活塞式压缩机级数的选择是根据制冷剂和设计工况的冷凝压力与蒸发压力之比来确定的，下列说法正确的是( )。",[553,555,557,559],{"key":20,"text":554,"correct":22},"以R717为制冷剂时，当压缩比≤6时，应采用单级压缩",{"key":24,"text":556,"correct":22},"以R717为制冷剂时，当压缩比＞8时，应采用双级压缩",{"key":27,"text":558,"correct":22},"以R22为制冷剂时，当压缩比≤10时，应采用单级压缩",{"key":31,"text":560,"correct":29},"以R134a为制冷剂时，只能采用单级压缩",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":455,"analysis":34},881096,"在如下面所示的四个建筑内设置的不同供暖系统中，需要在该建筑内的供暖水系统设置膨胀水箱的是哪几项？",[565,566,567,568],{"key":20,"text":34,"correct":29},{"key":24,"text":34,"correct":22},{"key":27,"text":34,"correct":29},{"key":31,"text":34,"correct":22},{"id":570,"libraryId":5,"type":62,"typeLabel":63,"stem":571,"options":572,"answer":27,"analysis":34},881097,"冷库制冷系统道设计中，压缩机吸气管道允许压力降相当于饱和制冷剂饱和温度降低( )。",[573,575,577,579],{"key":20,"text":574,"correct":29},"0.5℃",{"key":24,"text":576,"correct":29},"0.8℃",{"key":27,"text":578,"correct":22},"1.0℃",{"key":31,"text":580,"correct":29},"1.5℃",{"id":582,"libraryId":5,"type":62,"typeLabel":63,"stem":583,"options":584,"answer":31,"analysis":34},881098,"空气洁净技术主要目的在于创建一个( )的环境。",[585,587,589,591],{"key":20,"text":586,"correct":29},"舒适",{"key":24,"text":588,"correct":29},"健康",{"key":27,"text":590,"correct":29},"良好空气品质",{"key":31,"text":592,"correct":22},"满足工艺要求",{"id":594,"libraryId":5,"type":62,"typeLabel":63,"stem":595,"options":596,"answer":24,"analysis":34},881099,"对于严寒地区，内部发热量较大的商业建筑，下列夏季节能技术措施中，效果不显著的是( )。",[597,599,601,603],{"key":20,"text":598,"correct":29},"减小窗墙面积比",{"key":24,"text":600,"correct":22},"提高围护结构保温性能",{"key":27,"text":602,"correct":29},"设置自然通风装置",{"key":31,"text":604,"correct":29},"设置外遮阳",{"id":606,"libraryId":5,"type":62,"typeLabel":63,"stem":607,"options":608,"answer":27,"analysis":34},881100,"吹风口高度h一般为吹、吸风口间距离B的( )倍。",[609,611,613,615],{"key":20,"text":610,"correct":29},"0.15～0.2",{"key":24,"text":612,"correct":29},"0.01～0.1",{"key":27,"text":614,"correct":22},"0.01～0.15",{"key":31,"text":616,"correct":29},"0.2～0.3",[618,621,624,627,630,633],{"id":62,"name":619,"category":7,"favorite":620},"领导干部任职前廉政法规知识测试题",92,{"id":622,"name":623,"category":7,"favorite":62},595,"建筑结构与设备",{"id":625,"name":626,"category":7,"favorite":62},715,"招标采购专业知识与法律法规",{"id":628,"name":629,"category":7,"favorite":62},848,"市政方向-通用基础",{"id":631,"name":632,"category":7,"favorite":8},534,"BIM工程师",{"id":634,"name":632,"category":7,"favorite":8},535]