[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-24":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":634},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,24,50,2054,[13,35,48,61,73,86,99,112,124,136,149,161,173,185,198,210,222,235,248,260,272,284,296,308,319,331,343,355,368,380,392,404,418,430,442,454,466,478,490,502,514,526,538,550,562,574,586,598,610,622],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},881001,2,"多选题","对隔热材料的要求是( )。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","热导率小",true,{"key":24,"text":25,"correct":22},"B","不散发有毒或异味等对食品有污染的物质",{"key":27,"text":28,"correct":22},"C","难燃或不燃烧，且不易变质",{"key":30,"text":31,"correct":32},"D","地面、楼面采用的隔热材料，其抗压强度不应大于0.25MPa",false,"ABC","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},881002,"建筑物夏季空调冷负荷计算，建筑围护结构通过传热形成的逐时冷负荷的计算中，有关计算温度取值错误的是下列哪些选项？",[39,41,43,45],{"key":20,"text":40,"correct":32},"外窗：夏季空调室外计算逐时温度",{"key":24,"text":42,"correct":32},"屋面：夏季空调室外计算逐时综合温度",{"key":27,"text":44,"correct":22},"外墙：夏季空调室外计算日平均综合温度",{"key":30,"text":46,"correct":22},"邻室为非空调区的楼板：夏季空调室外计算日平均综合温度","CD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},881003,"设计防烟楼梯间及其前室机械加压送风系统时，防烟楼梯间及其前室两者余压值的搭配下列哪几项是合理的？( )",[52,54,56,58],{"key":20,"text":53,"correct":32},"防烟楼梯间40Pa，前室25Pa",{"key":24,"text":55,"correct":22},"防烟楼梯间40Pa，前室30Pa",{"key":27,"text":57,"correct":22},"防烟楼梯间50Pa，前室25Pa",{"key":30,"text":59,"correct":32},"防烟楼梯间50Pa，前室30Pa","BC",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":60,"analysis":34},881004,"关于高压蒸汽供暖系统的凝结水管，正确的是( )。",[65,67,69,71],{"key":20,"text":66,"correct":32},"不应向上抬升",{"key":24,"text":68,"correct":22},"疏水器后凝结水管允许抬升高度应经计算确定",{"key":27,"text":70,"correct":22},"疏水器后凝结水管上抬时均应设置止回阀",{"key":30,"text":72,"correct":32},"所有凝结水管都应设置于散热设备的下部",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":85,"analysis":34},881005,"下列制冷剂中，标准蒸发温度低于-20℃的是( )。",[77,79,81,83],{"key":20,"text":78,"correct":22},"R22",{"key":24,"text":80,"correct":32},"R142",{"key":27,"text":82,"correct":22},"R13",{"key":30,"text":84,"correct":22},"R12","ACD",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":98,"analysis":34},881006,"住宅燃气热水器的设置应( )。",[90,92,94,96],{"key":20,"text":91,"correct":22},"应安装在通风良好的房间或过道内",{"key":24,"text":93,"correct":22},"不得采用直接排气式热水器",{"key":27,"text":95,"correct":32},"密闭型热水器不得安装在浴室内",{"key":30,"text":97,"correct":32},"烟道排气式(半密闭型)热水器可以安装在浴室内","AB",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":111,"analysis":34},881007,"杭州某800床医院新建一栋住院楼，希望获得三星级绿色建筑标识，下列哪些建议是正确的？( )",[103,105,107,109],{"key":20,"text":104,"correct":22},"设计热电冷三联供系统，保证能源利用效率在75%以上",{"key":24,"text":106,"correct":32},"保证70%以上病房采光系数达到《建筑采光设计标准》要求",{"key":27,"text":108,"correct":32},"冷机能效等级为4级",{"key":30,"text":110,"correct":22},"设计VRF空调十新风系统","AD",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":60,"analysis":34},881008,"关于地源热泵机组采用地埋管换热系统的正确说法，应是下列哪几项？( )",[116,118,120,122],{"key":20,"text":117,"correct":32},"全年向土壤放热可与从土壤取热自动实现平衡",{"key":24,"text":119,"correct":22},"地埋管换热系统应采用动态负荷模拟设计法进行设计",{"key":27,"text":121,"correct":22},"冬季运行，地埋管进水(不加防冻液)温度过低时，机组将会停机保护",{"key":30,"text":123,"correct":32},"地埋管换热器计算时环路集管也应包括在地埋管换热器的长度内",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":60,"analysis":34},881009,"散热器选择以下说法正确的是( )。",[128,130,132,134],{"key":20,"text":129,"correct":32},"具有腐蚀性气体的工业建筑可采用耐腐蚀的散热器",{"key":24,"text":131,"correct":22},"采用钢制散热器应采用闭式系统",{"key":27,"text":133,"correct":22},"采用铝制散热器应选用内防腐型",{"key":30,"text":135,"correct":32},"蒸汽供暖系统不宜采用钢柱型散热器",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":148,"analysis":34},881010,"为防止蒸气压缩式制冷装置在运行中发生湿压缩，要求进入压缩机的制冷剂是( )。",[140,142,144,146],{"key":20,"text":141,"correct":32},"饱和液体",{"key":24,"text":143,"correct":22},"干饱和蒸气",{"key":27,"text":145,"correct":32},"湿蒸气",{"key":30,"text":147,"correct":22},"过热蒸气","BD",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":111,"analysis":34},881011,"关于洁净室压差的控制的描述，正确的为下列哪几项?( )。",[153,155,157,159],{"key":20,"text":154,"correct":22},"洁净室与周围的空间必须维持一定的压差",{"key":24,"text":156,"correct":32},"洁净室与周围的空间的压差必须为正压值",{"key":27,"text":158,"correct":32},"洁净室与周围的空间的压差必须为负压值",{"key":30,"text":160,"correct":22},"洁净室与周围的空间的压差值应按生产工艺要求决定",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":33,"analysis":34},881012,"垂直双管系统散热器立管的热补偿与固定，符合要求的是( )。",[165,167,169,171],{"key":20,"text":166,"correct":22},"立管长度小于20m时，可在立管中间设固定卡",{"key":24,"text":168,"correct":22},"立管长度大于20m时，应采取补偿措施",{"key":27,"text":170,"correct":22},"管道分支接点由管道伸缩引起的最大位移量应不大于20mm",{"key":30,"text":172,"correct":32},"管道分支接点由管道伸缩引起的最大位移量应不大于40mm",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":85,"analysis":34},881013,"供暖管道保温材料应采用非燃烧材料的是( )。",[177,179,181,183],{"key":20,"text":178,"correct":22},"高层工业建筑",{"key":24,"text":180,"correct":32},"低层工业建筑",{"key":27,"text":182,"correct":22},"体育馆",{"key":30,"text":184,"correct":22},"影剧院",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":197,"analysis":34},881014,"下列( )场所应设单独划分防烟分区。",[189,191,193,195],{"key":20,"text":190,"correct":32},"设备层",{"key":24,"text":192,"correct":22},"防烟楼梯间",{"key":27,"text":194,"correct":22},"消防电梯",{"key":30,"text":196,"correct":22},"地下室","BCD",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":85,"analysis":34},881015,"表面活性剂在溴化锂制冷机组中的作用是( )。",[202,204,206,208],{"key":20,"text":203,"correct":22},"强化传热",{"key":24,"text":205,"correct":32},"防止锈蚀",{"key":27,"text":207,"correct":22},"降低能耗",{"key":30,"text":209,"correct":22},"提高制冷量",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":98,"analysis":34},881016,"在运行公共建筑围护结构热工性能的权衡判断时，为使实际设计的建筑能耗不大于参照建筑的能耗，可采用以下哪些手段?( )。",[214,216,218,220],{"key":20,"text":215,"correct":22},"提高围护结构的热工性能",{"key":24,"text":217,"correct":22},"减少透明围护结构的面积",{"key":27,"text":219,"correct":32},"改变空调、供暖室内的设计参数",{"key":30,"text":221,"correct":32},"提高空调、供暖系统的系统能效比",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":234,"analysis":34},881017,"下述关于除尘系统设计的规定，错误的是( )。",[226,228,230,232],{"key":20,"text":227,"correct":22},"除尘系统的排风量，应按其全部同时工作的吸风点计算",{"key":24,"text":229,"correct":22},"风管的支管宜从主管的下面接出",{"key":27,"text":231,"correct":32},"风管的漏风率宜采用10%～15%",{"key":30,"text":233,"correct":22},"各并联环路压力损失的相对差额不宜超过15%","ABD",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":247,"analysis":34},881018,"为了保证建筑物的换气次数，降低空气渗透造成的能量损失，要求外窗及阳台门具有良好的气密性，下列选项正确的是( )。",[239,241,243,245],{"key":20,"text":240,"correct":22},"在冬季室外平均风速大于或等于3.0m／s的地区，对于1～6层建筑，不应低于现行国家标准规定的Ⅲ级水平",{"key":24,"text":242,"correct":22},"在冬季室外平均风速大于或等于3.0m\u002Fs的地区，对于7～30层建筑，不应低于Ⅱ级水平",{"key":27,"text":244,"correct":22},"在冬季室外平均风速小于3.0m／s的地区，对于1～6层建筑，不应低于Ⅳ级水平",{"key":30,"text":246,"correct":22},"在冬季室外平均风速小于3.0m\u002Fs的地区，对于7～30层建筑，不应低于Ⅲ级水平","ABCD",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":85,"analysis":34},881019,"下列关于房间冬季空调设计热负荷与采暖设计热负荷关系的表述中，错误的是( )。",[252,254,256,258],{"key":20,"text":253,"correct":22},"冬季空调设计热负荷与采暖设计热负荷相等",{"key":24,"text":255,"correct":32},"冬季空调设计热负荷大于采暖设计热负荷",{"key":27,"text":257,"correct":22},"冬季空调设计热负荷小于采暖设计热负荷",{"key":30,"text":259,"correct":22},"冬季空调设计热负荷可能大于、也可能小于采暖设计热负荷，视当地的气象条件而定",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":197,"analysis":34},881020,"关于事故通风，下列说法正确的是( )。",[264,266,268,270],{"key":20,"text":265,"correct":32},"当房间高度在6m及6m以下时换气次数为8次\u002Fh；高度为6m以上的房间，换气次数为4次\u002Fh",{"key":24,"text":267,"correct":22},"事故排风机的开关应分别设置在室内和室外便于开启的地方",{"key":27,"text":269,"correct":22},"当排出有剧毒的有害物时，应将它排到10m以上的大气中稀释",{"key":30,"text":271,"correct":22},"当生产中可能突然产生大量有害物质或易造成急性中毒或易燃、易爆的化学物质时，其换气次数应不小于12次\u002Fh，并应有自动报警装置",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":33,"analysis":34},881021,"侧孔面积相同的均匀送风管道的设计要求有( )。",[276,278,280,282],{"key":20,"text":277,"correct":22},"各孔口流量系数相同",{"key":24,"text":279,"correct":22},"各孔口处风管内静压相等",{"key":27,"text":281,"correct":22},"各孔口气流出流角至少为60°",{"key":30,"text":283,"correct":32},"风管断面尺寸形状保持不变",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":197,"analysis":34},881022,"选用弹簧隔振器需考虑下列哪些因素？( )",[288,290,292,294],{"key":20,"text":289,"correct":32},"应计入环境温度对隔振器压缩变形量的影响",{"key":24,"text":291,"correct":22},"当共振振幅较大时，宜与阻尼大的材料联合使用",{"key":27,"text":293,"correct":22},"设备的运转频率与隔振器的垂直方向的固有频率之比应大于等于2.5",{"key":30,"text":295,"correct":22},"隔振器与基础之间宜设置一定厚度的弹性隔振垫",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":247,"analysis":34},881023,"属于通风空调系统防火防爆措施的是( )。",[300,302,304,306],{"key":20,"text":301,"correct":22},"管道和设备的保温材料、消声材料和胶粘剂采用不燃材料或难燃材料",{"key":24,"text":303,"correct":22},"穿越空调机房的风管设置70℃防火阀",{"key":27,"text":305,"correct":22},"管道井与房间、走道相通的孔洞，其空隙处采用不燃材料填塞密实",{"key":30,"text":307,"correct":22},"垂直风管与每层水平风管交接处水平管段上设置70℃防火阀",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":310,"answer":148,"analysis":34},881024,[311,313,315,317],{"key":20,"text":312,"correct":32},"用户1和用户3的流量减小",{"key":24,"text":314,"correct":22},"用户1的水力失调度小于用户3",{"key":27,"text":316,"correct":32},"用户1和用户3的室温都升高，用户1升高得更多",{"key":30,"text":318,"correct":22},"用户1和用户3的室温都升高，用户3升高得更多",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":247,"analysis":34},881025,"应单独设置排风系统的情况是( )。",[323,325,327,329],{"key":20,"text":324,"correct":22},"两种或两种以上的有害物混合后可能引起燃烧或爆炸",{"key":24,"text":326,"correct":22},"混合后能形成毒害更大或腐蚀性的混合物、化合物",{"key":27,"text":328,"correct":22},"混合后易整体凝结并积聚粉尘",{"key":30,"text":330,"correct":22},"散发剧毒物质的房间和设备",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":47,"analysis":34},881026,"采用二级泵的空调冷水系统主要特点，下列哪几项是正确的？( )",[335,337,339,341],{"key":20,"text":336,"correct":32},"可实现变流量运行，二级泵采用台数控制即可，初投资高、运行能耗低",{"key":24,"text":338,"correct":32},"可实现变流量运行，冷源侧需设旁通管、初投资高、运行能耗较低",{"key":27,"text":340,"correct":22},"可实现变流量运行，冷源侧需设旁通管、初投资高、各支路阻力差异大、可实现运行节能",{"key":30,"text":342,"correct":22},"可实现变流量运行，一级泵可采用台数控制，末端装置需采用两通电动阀，一些情况下并不能实现运行节能",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":85,"analysis":34},881027,"下列对“遮阳系数”解释错误的是( )。",[347,349,351,353],{"key":20,"text":348,"correct":22},"被遮挡的窗玻璃太阳辐射得热与透过3mm厚透明玻璃的太阳辐射得热之比值",{"key":24,"text":350,"correct":32},"实际透过窗玻璃的太阳辐射得热与透过3.mm厚透明玻璃的太阳辐射得热之比值",{"key":27,"text":352,"correct":22},"遮阳系数与实际透过窗玻璃的太阳辐射得热成反比",{"key":30,"text":354,"correct":22},"《公建节能》对所有建筑气候分区外窗的玻璃遮阳系数都有不同程度的限制",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":367,"analysis":34},881028,"从美国进口1台按照美国制冷协会(ARI)标准制造的冷水机组，在我国使用后发现其实际制冷量低于铭牌值，下列哪几项原因是正确的？( )",[359,361,363,365],{"key":20,"text":360,"correct":22},"按我国水质，ARI标准中水污垢系数偏低",{"key":24,"text":362,"correct":32},"按我国水质，ARI标准中水污垢系数偏高",{"key":27,"text":364,"correct":22},"按我国多数城市的夏季气温，ARI标准中冷却水温度偏低",{"key":30,"text":366,"correct":32},"按我国多数城市的夏季气温，ARI标准中冷却水温度偏高","AC",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":367,"analysis":34},881029,"选择通风空调用风机时，依据的主要技术参数为下列哪几项？( )",[372,374,376,378],{"key":20,"text":373,"correct":22},"系统阻力",{"key":24,"text":375,"correct":32},"风机全压",{"key":27,"text":377,"correct":22},"系统风量",{"key":30,"text":379,"correct":32},"风机的电动机功率",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":111,"analysis":34},881030,"白条猪肉的冷却不采用( )。",[384,386,388,390],{"key":20,"text":385,"correct":22},"真空冷却",{"key":24,"text":387,"correct":32},"差压式冷却",{"key":27,"text":389,"correct":32},"通风冷却",{"key":30,"text":391,"correct":22},"冷水冷却",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":111,"analysis":34},881031,"关于温湿度独立控制空调系统，下列哪些说法是不正确的？( )",[396,398,400,402],{"key":20,"text":397,"correct":22},"新风除湿处理应采用溶液除湿方式",{"key":24,"text":399,"correct":32},"室内显热冷负荷可以采用辐射板处理",{"key":27,"text":401,"correct":32},"新风除湿处理可以采用冷却除湿方式",{"key":30,"text":403,"correct":22},"室内显热冷负荷应采用风机盘管处理",{"id":405,"libraryId":5,"type":406,"typeLabel":407,"stem":408,"options":409,"answer":20,"analysis":34},881032,1,"单选题","风管内气流的静压与动压比值越大，管壁孔的气流出流角( )。",[410,412,414,416],{"key":20,"text":411,"correct":22},"越大",{"key":24,"text":413,"correct":32},"越小",{"key":27,"text":415,"correct":32},"相同",{"key":30,"text":417,"correct":32},"不确定",{"id":419,"libraryId":5,"type":406,"typeLabel":407,"stem":420,"options":421,"answer":20,"analysis":34},881033,"有三种容积式单级制冷压缩机，当实际工况压缩比≥4时，压缩机的等熵效率由低到高的排序应是下列哪一项？( )",[422,424,426,428],{"key":20,"text":423,"correct":22},"活塞式压缩机、滚动转子式压缩机、涡旋式压缩机",{"key":24,"text":425,"correct":32},"滚动转子式压缩机、涡旋式压缩机、活塞式压缩机",{"key":27,"text":427,"correct":32},"涡旋式压缩机、滚动转子式压缩机、活塞式压缩机",{"key":30,"text":429,"correct":32},"活塞式压缩机、涡旋式压缩机、滚动转子式压缩机",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":85,"analysis":34},881034,"现行绿色建筑评价指标体系由六类指标组成，每类指标均包括哪些项？( )",[434,436,438,440],{"key":20,"text":435,"correct":22},"控制项",{"key":24,"text":437,"correct":32},"强制项",{"key":27,"text":439,"correct":22},"一般项",{"key":30,"text":441,"correct":22},"优选项",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":367,"analysis":34},881035,"自然通风可以进行建筑物的通风，表述正确的应为下列哪些项？",[446,448,450,452],{"key":20,"text":447,"correct":22},"建筑迎风面为正压，原因在于滞留区气流动压转变为静压",{"key":24,"text":449,"correct":32},"建筑物中和面余压为零，中和面以上气流由内向外流动，中和面以下气流由外向内流动",{"key":27,"text":451,"correct":22},"建筑物中和面的位置可以人为调整",{"key":30,"text":453,"correct":32},"送风窗孔面积减小，排风窗孔面积增大，造成建筑物中和面上移",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":247,"analysis":34},881036,"进行通风气流组织设计时，应遵循的原则是( )。",[458,460,462,464],{"key":20,"text":459,"correct":22},"将新鲜空气送到作业地带或操作人员经常停留的工作地点，应避免将有害物吹向工作区",{"key":24,"text":461,"correct":22},"有害物源散发的有害物气体温度比周围空气高，或者车间存在上升气流，无论有害气体密度大小，均应采用下送上排的方式",{"key":27,"text":463,"correct":22},"同时散发热、蒸汽和有害气体，或仅散发密度比空气小的有害气体的生产建筑，除设局部排风外，宜在上部区域进行自然或机械的全面排风，其排风量不宜小于每小时一次换气当房间高度大于6m时，排风量可按每平方米地面面积每小时6立方米计算",{"key":30,"text":465,"correct":22},"通风房间气流组织主要方式有：上送上排、下送下排和中间送上下排",{"id":467,"libraryId":5,"type":406,"typeLabel":407,"stem":468,"options":469,"answer":20,"analysis":34},881037,"前室的送风口应每层设置，每个风口的有效面积按( )系统总风量确定。",[470,472,474,476],{"key":20,"text":471,"correct":22},"1／3",{"key":24,"text":473,"correct":32},"1／2",{"key":27,"text":475,"correct":32},"1／4",{"key":30,"text":477,"correct":32},"1／5",{"id":479,"libraryId":5,"type":406,"typeLabel":407,"stem":480,"options":481,"answer":24,"analysis":34},881038,"下列四种燃气输送管道，不应敷设在地下室内的是下列哪一项？( )",[482,484,486,488],{"key":20,"text":483,"correct":32},"天然气管道",{"key":24,"text":485,"correct":22},"液化石油气管道",{"key":27,"text":487,"correct":32},"固体燃料干馏煤气管道",{"key":30,"text":489,"correct":32},"固体燃料气化煤气管道",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":247,"analysis":34},881039,"与蒸汽相比，热水作为集中热网热媒的优点有( )。",[494,496,498,500],{"key":20,"text":495,"correct":22},"热水供热系统热能利用率高",{"key":24,"text":497,"correct":22},"减少热网热损失，又能较好地满足卫生要求",{"key":27,"text":499,"correct":22},"蓄热能力高",{"key":30,"text":501,"correct":22},"供热半径大",{"id":503,"libraryId":5,"type":406,"typeLabel":407,"stem":504,"options":505,"answer":27,"analysis":34},881040,"某一立式冷凝器，其进出口水温分别为20℃和25℃，则其冷凝温度可确定为( )℃。",[506,508,510,512],{"key":20,"text":507,"correct":32},"26.5",{"key":24,"text":509,"correct":32},"25.5",{"key":27,"text":511,"correct":22},"28.5",{"key":30,"text":513,"correct":32},"30.5",{"id":515,"libraryId":5,"type":406,"typeLabel":407,"stem":516,"options":517,"answer":30,"analysis":34},881041,"在供暖管网中安全阀的安装做法，哪项是不必要的?( )。",[518,520,522,524],{"key":20,"text":519,"correct":32},"蒸汽管道和设备上的安全阀应有通向室外的排汽管",{"key":24,"text":521,"correct":32},"热水管道和设备上的安全阀应有通到安全地点的排水管",{"key":27,"text":523,"correct":32},"安全阀后的排水管应有足够的截面积",{"key":30,"text":525,"correct":22},"安全阀后的排汽管上应设检修阀",{"id":527,"libraryId":5,"type":406,"typeLabel":407,"stem":528,"options":529,"answer":20,"analysis":34},881042,"设置全面通风时，当散放气体的密度比空气轻，宜从房间哪个区域排出？( )",[530,532,534,536],{"key":20,"text":531,"correct":22},"上部",{"key":24,"text":533,"correct":32},"下部",{"key":27,"text":535,"correct":32},"中部",{"key":30,"text":537,"correct":32},"中部偏下",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":85,"analysis":34},881043,"关于制冷机房位置选择时，下列说法正确的是( )。",[542,544,546,548],{"key":20,"text":543,"correct":22},"单独修建的制冷机房宜布置在全厂厂区夏季主导方向的下风向",{"key":24,"text":545,"correct":32},"在动力站区域内，一般应布置在乙炔站、锅炉房、煤气站、堆煤站等下风向",{"key":27,"text":547,"correct":22},"制冷机房的位置应尽可能设在冷负荷中心，并力求缩短载冷剂和冷却水管路",{"key":30,"text":549,"correct":22},"当制冷机房是全部电负荷时，还应考虑靠近电源",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":33,"analysis":34},881044,"下列对热力站内加热器的说法，正确的是( )。",[554,556,558,560],{"key":20,"text":555,"correct":22},"容积式加热器计算传热系数时宜按考虑水垢热阻的方法进行计算",{"key":24,"text":557,"correct":22},"间接连接采暖系统应尽量选择工作可靠、传热性能良好的加热器",{"key":27,"text":559,"correct":22},"加热器组一、二次侧进口及出口应设总阀门，并联工作的加热器，每台加热器一、二次侧进口及出口宜设阀门",{"key":30,"text":561,"correct":32},"串联连接的加热器宜按同程连接设计",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":247,"analysis":34},881045,"热泵用蒸汽压缩机相对于一般制冷用压缩机的技术性能有更高的要求，以同种机型、相同的名义制冷量的压缩机进行比较，更高的要求为下列哪几项？",[566,568,570,572],{"key":20,"text":567,"correct":22},"应承受更高的压缩比",{"key":24,"text":569,"correct":22},"应具有较小的相对余隙容积",{"key":27,"text":571,"correct":22},"应具有更高的可靠性和使用寿命",{"key":30,"text":573,"correct":22},"热泵用压缩机宜采用封闭式压缩机",{"id":575,"libraryId":5,"type":406,"typeLabel":407,"stem":576,"options":577,"answer":20,"analysis":34},881046,"纸张的生产过程是：平铺在毛毯上的纸张，经过抄纸机烘箱的脱水、烘干，最后取纸张成品。烘箱采用的是热风干燥，热风的热源为0.2MPa的蒸汽，蒸汽用量是1500kg\u002Fh，用后的蒸汽凝结水需回收，试问该情况下疏水器的选择倍率应是多少？",[578,580,582,584],{"key":20,"text":579,"correct":22},"2倍",{"key":24,"text":581,"correct":32},"3倍",{"key":27,"text":583,"correct":32},"4倍",{"key":30,"text":585,"correct":32},"5倍",{"id":587,"libraryId":5,"type":406,"typeLabel":407,"stem":588,"options":589,"answer":24,"analysis":34},881047,"在采用空气源热泵冷热水机组时应考虑的主要因素是下列哪一项？( )",[590,592,594,596],{"key":20,"text":591,"correct":32},"冬夏季室外温度和所需冷热量的大小",{"key":24,"text":593,"correct":22},"夏季室外温度、冬季室外温湿度和所需冷热量的大小",{"key":27,"text":595,"correct":32},"冬夏季室外温度和价格",{"key":30,"text":597,"correct":32},"所需冷热量的大小",{"id":599,"libraryId":5,"type":406,"typeLabel":407,"stem":600,"options":601,"answer":24,"analysis":34},881048,"用吸附法除去气体中有害物质，吸附剂的动活性与静活性的关系下列哪一项是正确的？( )",[602,604,606,608],{"key":20,"text":603,"correct":32},"动活性大于静活性",{"key":24,"text":605,"correct":22},"动活性小于静活性",{"key":27,"text":607,"correct":32},"动活性稍大于静活性",{"key":30,"text":609,"correct":32},"动活性等于静活性",{"id":611,"libraryId":5,"type":406,"typeLabel":407,"stem":612,"options":613,"answer":27,"analysis":34},881049,"对排烟口的设置要求，下列( )是符合规范要求的。",[614,616,618,620],{"key":20,"text":615,"correct":32},"排烟口的风速不应大于10m\u002Fs",{"key":24,"text":617,"correct":32},"防烟分区内排烟口距最远点的水平距离不宜大于30m",{"key":27,"text":619,"correct":22},"排烟口为常闭，应具备手动和自动开启功能",{"key":30,"text":621,"correct":32},"对于面积为60㎡的半地下房间，机械排烟系统的排烟口可设在疏散走廊内",{"id":623,"libraryId":5,"type":406,"typeLabel":407,"stem":624,"options":625,"answer":30,"analysis":34},881050,"某办公室有工作人员、照明灯具、办公设备及外墙外窗，室内保持40Pa正压，试问计算该办公室的得热量，不应计入下列哪一项？( )",[626,628,630,632],{"key":20,"text":627,"correct":32},"围护结构的传热量",{"key":24,"text":629,"correct":32},"人体散热量",{"key":27,"text":631,"correct":32},"照明灯具、办公设备的散热量",{"key":30,"text":633,"correct":22},"空气渗透得热量",[635,638,641,644,647,650],{"id":406,"name":636,"category":7,"favorite":637},"领导干部任职前廉政法规知识测试题",92,{"id":639,"name":640,"category":7,"favorite":406},595,"建筑结构与设备",{"id":642,"name":643,"category":7,"favorite":406},715,"招标采购专业知识与法律法规",{"id":645,"name":646,"category":7,"favorite":406},848,"市政方向-通用基础",{"id":648,"name":649,"category":7,"favorite":8},534,"BIM工程师",{"id":651,"name":649,"category":7,"favorite":8},535]