[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-23":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":632},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,23,50,2054,[13,34,48,61,74,86,99,111,123,136,148,160,172,185,197,209,221,234,247,259,271,284,296,309,321,333,345,356,368,380,392,404,416,428,440,452,464,476,488,500,512,524,536,548,560,572,584,596,608,620],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":32,"analysis":33},880951,2,"多选题","下列关于风机降噪，正确的做法是( )。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","选用高效率低噪声风机，尽可能采用后倾叶片的离心式风机，使其工作点位于或接近于风机的最高效率点",true,{"key":24,"text":25,"correct":22},"B","系统风量一定时，风机安全因数不宜过大，必要时采用送回风机共同承担系统总阻力",{"key":27,"text":28,"correct":22},"C","风机进出口处的管道不应急剧转弯",{"key":30,"text":31,"correct":22},"D","风机进出口处的管道应设柔性连接","ABCD","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":47,"analysis":33},880952,"下列关于组合式空调机组的设计原则，错误的有( )。",[38,40,42,45],{"key":20,"text":39,"correct":22},"组合式空调机组的制冷量和制热量应按产品样本中的额定值选取",{"key":24,"text":41,"correct":22},"高压喷雾加湿器出口紧接着设置过滤器",{"key":27,"text":43,"correct":44},"对于温度控制精度要求较高的工艺性空调，空气加热器应设置在表冷器的出口",false,{"key":30,"text":46,"correct":22},"消声器应尽量由组合式空调机组配带，避免在风管上设置消声器","ABD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":33},880953,"在相对湿度相同的情况下，气温与建筑空调系统能耗关系的说法中，正确的是( )。",[52,54,56,58],{"key":20,"text":53,"correct":44},"可以根据当时的气温评判当时空调系统能耗的高低",{"key":24,"text":55,"correct":44},"可以根据当日的平均气温评判当日空调系统能耗的高低",{"key":27,"text":57,"correct":22},"不能根据当时的气温评判当时空调系统能耗的高低",{"key":30,"text":59,"correct":22},"不能根据当日的平均气温评判当日空调系统能耗的高低","CD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":33},880954,"下列部位亦设专设通气管的是( )。",[65,67,69,71],{"key":20,"text":66,"correct":22},"生活排水立管所承担的卫生器具排水设计流量，当超过仅设伸顶通气管的排水立管最大排水能力时",{"key":24,"text":68,"correct":22},"建筑标准要求较高的多层住宅的生活污水立管",{"key":27,"text":70,"correct":22},"公共建筑10层及10层以上高层建筑的生活污水立管",{"key":30,"text":72,"correct":44},"每个生活立管的顶部","ABC",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":47,"analysis":33},880955,"等焓加湿的主要设备包括( )。",[78,80,82,84],{"key":20,"text":79,"correct":22},"喷水室",{"key":24,"text":81,"correct":22},"离心加湿器",{"key":27,"text":83,"correct":44},"电加湿器",{"key":30,"text":85,"correct":22},"超声波加湿器",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":98,"analysis":33},880956,"水蓄冷系统中钢筋混凝土水蓄冷槽的设置，正确的是( )。",[90,92,94,96],{"key":20,"text":91,"correct":44},"确定水蓄冷槽的容积时，对蓄冷槽的类型不进行修正",{"key":24,"text":93,"correct":22},"同一蓄冷槽采用内保温做法与采用外保温做法相比较，前者可避免冷桥产生",{"key":27,"text":95,"correct":44},"同一蓄冷槽采用内保温做法与采用外保温做法相比较，前者的蓄冷量利用率更高",{"key":30,"text":97,"correct":22},"同一蓄冷槽采用内保温做法与采用外保温做法相比较，前者与外界环境接触传热面积要小","BD",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":47,"analysis":33},880957,"在夏季空调散湿量计算时，应包括( )。",[103,105,107,109],{"key":20,"text":104,"correct":22},"渗透空气带人的湿量",{"key":24,"text":106,"correct":22},"餐厅火锅的散湿量",{"key":27,"text":108,"correct":44},"清洁拖地的散湿量",{"key":30,"text":110,"correct":22},"设备的散湿量",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":73,"analysis":33},880958,"改变机器露点的方法有( )。",[115,117,119,121],{"key":20,"text":116,"correct":22},"调节预热器加热量",{"key":24,"text":118,"correct":22},"调节新、回风混合比",{"key":27,"text":120,"correct":22},"调节冷冻水温度",{"key":30,"text":122,"correct":44},"调节旁通风门",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":135,"analysis":33},880959,"冷藏库制冷系统包括( )形式。",[127,129,131,133],{"key":20,"text":128,"correct":44},"动力供液系统",{"key":24,"text":130,"correct":22},"重力供液系统",{"key":27,"text":132,"correct":22},"氨泵供液系统",{"key":30,"text":134,"correct":22},"直接膨胀供液系统","BCD",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":98,"analysis":33},880960,"高层建筑给水系统在使用中，下列哪些情况不会发生水锤现象？",[140,142,144,146],{"key":20,"text":141,"correct":44},"水泵启动瞬间",{"key":24,"text":143,"correct":22},"阀门突然打开",{"key":27,"text":145,"correct":44},"水泵供电突然中断",{"key":30,"text":147,"correct":22},"存水池被水泵抽空",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":32,"analysis":33},880961,"当风机供给的风量不能符合要求时，可以采取的方法是( )。",[152,154,156,158],{"key":20,"text":153,"correct":22},"减少或增加管网系统的压力损失",{"key":24,"text":155,"correct":22},"更换风机",{"key":27,"text":157,"correct":22},"改变风机叶轮的转速",{"key":30,"text":159,"correct":22},"调节并联风机的开启台数",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":73,"analysis":33},880962,"洁净室及洁净区空气中悬浮粒子洁净度等级的表述应包含下列哪几项?( )。",[164,166,168,170],{"key":20,"text":165,"correct":22},"等级级别",{"key":24,"text":167,"correct":22},"占用状态",{"key":27,"text":169,"correct":22},"考虑粒子的控制粒径",{"key":30,"text":171,"correct":44},"考虑粒子的物化性质",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":184,"analysis":33},880963,"在计算室内空调冷负荷时，下列关于发热量计算的说法正确的是( )。",[176,178,180,182],{"key":20,"text":177,"correct":22},"电冰箱的发热量按压缩机功率计算",{"key":24,"text":179,"correct":44},"计算机的发热量按安装功率计算",{"key":27,"text":181,"correct":44},"灯的发热量按灯泡的功率计算",{"key":30,"text":183,"correct":22},"确定人员发热量时应考虑人员的年龄和性别构成","AD",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":73,"analysis":33},880964,"水环热泵系统的特点有( )。",[189,191,193,195],{"key":20,"text":190,"correct":22},"节省能量，机组运行能效比高",{"key":24,"text":192,"correct":22},"运行可靠，控制简单",{"key":27,"text":194,"correct":22},"施工方便，管道数量",{"key":30,"text":196,"correct":44},"使用灵活，能进行局部区域的温度控制",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":98,"analysis":33},880965,"有关多联式空调(热泵)机组的说法，下列哪几项是错误的?( )。",[201,203,205,207],{"key":20,"text":202,"correct":44},"多联式空调(热泵)机组压缩机采用数码涡旋压缩机优于变频压缩机，更节能",{"key":24,"text":204,"correct":22},"室内机和新风机宜由一台多联式空调(热泵)室外机组拖动",{"key":27,"text":206,"correct":44},"多联式空调(热泵)机组运行正常的关键之一是要解决好系统的回油的问题",{"key":30,"text":208,"correct":22},"多联式空调(热泵)机组使用地域基本不受限制",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":47,"analysis":33},880966,"计算分户采暖系统热负荷时，应( )。",[213,215,217,219],{"key":20,"text":214,"correct":22},"最好通过计算确定户间热负荷",{"key":24,"text":216,"correct":22},"户间热负荷所附加的热量不应统计在采暖系统的总热负荷内",{"key":27,"text":218,"correct":44},"对于高大空间公共建筑考虑高度附加",{"key":30,"text":220,"correct":22},"进深大于6m的房间，宜以距外墙6m为界分区，分别计算热负荷和进行管线布置",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":233,"analysis":33},880967,"降低薄钢板散热器腐蚀速度的有效和可行的设计措施是( )。",[225,227,229,231],{"key":20,"text":226,"correct":22},"采用闭式系统",{"key":24,"text":228,"correct":22},"控制系统中水的含氧量",{"key":27,"text":230,"correct":44},"降低热媒温度和系统工作压力",{"key":30,"text":232,"correct":44},"避免在同一系统中多种材质的散热器、管道、阀门和构配件混装","AB",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":246,"analysis":33},880968,"关于多联式空调(热泵)机组的制冷综合性能系数，表述正确的是下列哪几项？( )",[238,240,242,244],{"key":20,"text":239,"correct":44},"制冷综合性能系数随机组制冷量自70%负荷率增加至100%负荷率而提高",{"key":24,"text":241,"correct":22},"制冷综合性能系数随机组制冷量自70%负荷率增加至100%负荷率而减小",{"key":27,"text":243,"correct":22},"制冷综合性能系数是反映机组部分负荷的制冷效率",{"key":30,"text":245,"correct":44},"制冷综合性能系数是反映机组全负荷的制冷效率","BC",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":184,"analysis":33},880969,"水表面自然蒸发使空气状态发生变化，下列哪几项是正确的？( )",[251,253,255,257],{"key":20,"text":252,"correct":22},"空气温度降低、湿度增加",{"key":24,"text":254,"correct":44},"空气温度升高、湿度增加",{"key":27,"text":256,"correct":44},"空气温度不变、湿度增加",{"key":30,"text":258,"correct":22},"空气比焓不变、湿度增加",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":73,"analysis":33},880970,"为防止A室的有害气体扩散到无有害物产生的相邻B室，下列措施中合理的是( )。风",[263,265,267,269],{"key":20,"text":264,"correct":22},"A.对A室机械排",{"key":24,"text":266,"correct":22},"对B室机械送风",{"key":27,"text":268,"correct":22},"B室机械送风，A室机械排风",{"key":30,"text":270,"correct":44},"B两室同时机械排风",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":283,"analysis":33},880971,"散热器恒温控制阀的选用和设置，符合规定的是( )。",[275,277,279,281],{"key":20,"text":276,"correct":22},"垂直或水平双管供暖系统每组散热器的供水支管上安装高阻恒温控制阀",{"key":24,"text":278,"correct":44},"5层以上的垂直式系统宜采用有预设阻力调节功能的恒温控制阀",{"key":27,"text":280,"correct":22},"当散热器有罩时，应采用温包外置式恒温控制阀",{"key":30,"text":282,"correct":22},"单管跨越式系统应采用低阻力恒温控制阀","ACD",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":47,"analysis":33},880972,"严寒地区冬季使用的空气加热器，下列哪些防冻措施是正确的？( )",[288,290,292,294],{"key":20,"text":289,"correct":22},"设置空气预热器，其水路上不设置自动调节阀",{"key":24,"text":291,"correct":22},"新风人口设密闭多叶阀或保温风阀，其启闭与风机的开停联锁",{"key":27,"text":293,"correct":44},"设置热水调节阀与风机同时启闭的联锁装置",{"key":30,"text":295,"correct":22},"热水调节阀设最小开度控制，并在必要时加大开度",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":308,"analysis":33},880973,"在供暖系统的下列施工做法中，有哪几项不合理，可能会产生系统运行故障？",[300,302,304,306],{"key":20,"text":301,"correct":22},"单管水平串联系统(上进下出)中，某两组散热器端部相距200mm，在其连接支管上可不设置管卡",{"key":24,"text":303,"correct":44},"蒸汽干管变径成底平偏心连接",{"key":27,"text":305,"correct":22},"供暖系统采用铝塑复合管隐蔽敷设时，其弯曲部分采用成品弯",{"key":30,"text":307,"correct":44},"在没有说明的情况下，静态水力平衡阀的前后管段长度分别不小于5倍、2倍管径","AC",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":308,"analysis":33},880974,"下列哪几项符合人民防空地下室通风空调设计的要求？( )",[313,315,317,319],{"key":20,"text":314,"correct":22},"战时应按防护单元设置独立通风空调系统",{"key":24,"text":316,"correct":44},"平时应按防火分区设置通风空调系统",{"key":27,"text":318,"correct":22},"平时与战时使用要求不一致时应采取平战功能转换措施",{"key":30,"text":320,"correct":44},"战时进风系统宜设有清洁、滤毒和隔绝三种通风方式",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":283,"analysis":33},880975,"对洁净室或洁净区进行测试时，下列哪几项是正确的？( )",[325,327,329,331],{"key":20,"text":326,"correct":22},"洁净室静压差的测定应在所有的门关闭时进行",{"key":24,"text":328,"correct":44},"洁净区静压差测定的最长时间间隔为12个月",{"key":27,"text":330,"correct":22},"测试洁净度时，如洁净室或洁净区仅有一个采样点，则该点应至少采样3次",{"key":30,"text":332,"correct":22},"生物洁净室应进行浮游菌、沉降菌的测试",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":73,"analysis":33},880976,"建筑耗热量简化计算时，采取近似处理，表述正确的应是下列哪几项？",[337,339,341,343],{"key":20,"text":338,"correct":22},"计算房间与相邻房间温差小于5℃时，不计算耗热量",{"key":24,"text":340,"correct":22},"伸缩缝或沉降缝按外墙基本耗热量的30%计算",{"key":27,"text":342,"correct":22},"内门的传热系数按隔墙的传热系数考虑",{"key":30,"text":344,"correct":44},"按外墙的外包尺寸计算围护结构的面积",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":283,"analysis":33},880977,"设计事故通风系统时，正确的是( )。",[349,351,352,354],{"key":20,"text":350,"correct":22},"事故通风量应根据事故放散物的种类、安全与卫生浓度要求按全面通风计算",{"key":24,"text":33,"correct":44},{"key":27,"text":353,"correct":22},"室内事故吸风口应设在放散物量可能最大或积聚最多的地点",{"key":30,"text":355,"correct":22},"室外排风口高度应高于周边20m范围内最高建筑屋面3m以上",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":233,"analysis":33},880978,"关于蒸气压缩循环冷水(热泵)机组的IPLV值的说法，正确的是( )。",[360,362,364,366],{"key":20,"text":361,"correct":22},"IPLV值是制冷机组在部分负荷下的性能表现",{"key":24,"text":363,"correct":22},"同一地区、同类建筑采用IPLV数值高的机组，有利于节能",{"key":27,"text":365,"correct":44},"同一地区、同类建筑采用IPLV数值高的机组，不利于节能",{"key":30,"text":367,"correct":44},"IPLV值是制冷机组性能与系统负荷动态特性的匹配反映",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":32,"analysis":33},880979,"通风空调系统在下列哪些情况下需设防火阀？( )",[372,374,376,378],{"key":20,"text":373,"correct":22},"管道穿越防火分区处",{"key":24,"text":375,"correct":22},"竖直风管与每层水平风管交接处水平管段上",{"key":27,"text":377,"correct":22},"风管穿越变形缝处的两侧",{"key":30,"text":379,"correct":22},"风管穿越空调机房隔墙处",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":60,"analysis":33},880980,"关于吸收法，下列叙述正确的是( )。",[384,386,388,390],{"key":20,"text":385,"correct":44},"吸收法是用液体净化排气中有害气体或粉尘的一种方法",{"key":24,"text":387,"correct":44},"使用的液体称为吸收质",{"key":27,"text":389,"correct":22},"吸收可分为物理吸收和化学吸收",{"key":30,"text":391,"correct":22},"为提高吸收效率，通常采用气液逆流方式",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":246,"analysis":33},880981,"居住建筑采暖设计计算建筑物内部得热时，下列哪几项是正确的？",[396,398,400,402],{"key":20,"text":397,"correct":44},"从建筑热负荷中扣除",{"key":24,"text":399,"correct":22},"不从建筑热负荷中扣除",{"key":27,"text":401,"correct":22},"对严寒、寒冷地区的住宅，应从建筑耗热量中扣除",{"key":30,"text":403,"correct":44},"均不从建筑耗热量中扣除",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":73,"analysis":33},880982,"对风管的单位长度摩擦阻力损失(即比摩阻)的修正需要的是( )。",[408,410,412,414],{"key":20,"text":409,"correct":22},"空气密度和黏度",{"key":24,"text":411,"correct":22},"空气温度和大气压力",{"key":27,"text":413,"correct":22},"管壁粗糙度",{"key":30,"text":415,"correct":44},"空气的湿度",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":283,"analysis":33},880983,"在易燃易爆环境中，关于空调系统调节阀执行器选择的表述中，不正确的是( )。",[420,422,424,426],{"key":20,"text":421,"correct":22},"可以采用电动执行器或气动执行器",{"key":24,"text":423,"correct":44},"应采用气动执行器",{"key":27,"text":425,"correct":22},"可以采用电动执行器",{"key":30,"text":427,"correct":22},"不宜采用气动执行器",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":308,"analysis":33},880984,"某建筑采用垂直单管热水供暖系统，系统运行时，立管Ⅰ的水力失调度为1.1，立管Ⅱ的水力失调度为0.9，与各立管连接的房间室温与设计室温相比，下列哪些说法是正确的？( )",[432,434,436,438],{"key":20,"text":433,"correct":22},"与立管工连接的房间室温普遍提高，下层房间比上层房间室温更高",{"key":24,"text":435,"correct":44},"与立管工连接的房间室温普遍提高，上层房间比下层房间室温更高",{"key":27,"text":437,"correct":22},"与立管Ⅱ连接的房间室温普遍降低，下层房间比上层房间室温降得更低",{"key":30,"text":439,"correct":44},"与立管Ⅱ连接的房间室温普遍降低，上层房间比下层房间室温降得更低",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":47,"analysis":33},880985,"热泵热水机的性能系数，除了产品本身的优劣以外，还与以下哪些因素有关系？( )",[444,446,448,450],{"key":20,"text":445,"correct":22},"与目标水温的高低成反比",{"key":24,"text":447,"correct":22},"与初始水温的高低成反比",{"key":27,"text":449,"correct":44},"空气源热泵热水机与环境温度的高低成反比",{"key":30,"text":451,"correct":22},"水源热泵热水机与水源温度的高低成正比",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":233,"analysis":33},880986,"办公楼采用多联机空调方案时，空调冷负荷计算的选项中正确的是( )。",[456,458,460,462],{"key":20,"text":457,"correct":22},"在办公室空调冷负荷计算时应考虑间歇附加系数",{"key":24,"text":459,"correct":22},"与会议室相邻的办公室的空调冷负荷计算应考虑与会议室隔墙的传热所形成的冷负荷",{"key":27,"text":461,"correct":44},"在办公室空调冷负荷计算时不应考虑间歇附加系数",{"key":30,"text":463,"correct":44},"与会议室相邻的办公室的空调冷负荷计算不应考虑与会议室隔墙的传热所形成的冷负荷",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":246,"analysis":33},880987,"人防地下室两个以上防护单元平时合并设置一套通风系统时( )规定是正确的。",[468,470,472,474],{"key":20,"text":469,"correct":44},"每个防护单元宜设置战时独立通风系统",{"key":24,"text":471,"correct":22},"每个防护单元必须设置战时独立通风系统",{"key":27,"text":473,"correct":22},"临战转换时两个防护单元之间隔墙上的平时通风管应按规定的时间及防护要求进行封堵",{"key":30,"text":475,"correct":44},"临战转换时两个防护单元之间隔墙上的平时通风管宜按规定的时间及防护要求进行封堵",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":233,"analysis":33},880988,"换热机房热计量装置的流量传感器应安装在一次管网的回水管上，原.因是( )。",[480,482,484,486],{"key":20,"text":481,"correct":22},"高温水的温差大、流量小、管径较小，可节省计量设备投资",{"key":24,"text":483,"correct":22},"回水温度较低",{"key":27,"text":485,"correct":44},"回水压力较低",{"key":30,"text":487,"correct":44},"测量精度高",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":98,"analysis":33},880989,"冷热电三联供系统中，设备配置及系统设计应符合下列哪些原则？( )",[492,494,496,498],{"key":20,"text":493,"correct":44},"以冷、热负荷定发电量",{"key":24,"text":495,"correct":22},"以热负荷定发电量",{"key":27,"text":497,"correct":44},"优先满足本建筑的机电系统用电",{"key":30,"text":499,"correct":22},"满足本建筑的机电系统的最大用电量",{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":246,"analysis":33},880990,"下列哪些高温热水供暖系统形式有利于降低定压水箱标高？( )",[504,506,508,510],{"key":20,"text":505,"correct":44},"上供下回式系统",{"key":24,"text":507,"correct":22},"下供下回式系统",{"key":27,"text":509,"correct":22},"下供上回式系统",{"key":30,"text":511,"correct":44},"上供中回式系统",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":233,"analysis":33},880991,"某三层办公建筑的空调水系统调试时，每次开机前必须先补水，否则无法正常运行。分析可能的原因，应是下列选项中的哪几项？",[516,518,520,522],{"key":20,"text":517,"correct":22},"空调水系统有漏水点",{"key":24,"text":519,"correct":22},"空调水系统管路中含有较多空气(未排净)",{"key":27,"text":521,"correct":44},"水泵的流量不足",{"key":30,"text":523,"correct":44},"膨胀水箱的底部与水系统最高点的高差过大",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":233,"analysis":33},880992,"制冷系统中引入回热器后，将使( )。",[528,530,532,534],{"key":20,"text":529,"correct":22},"制冷剂在节流阀前得到进一步过冷",{"key":24,"text":531,"correct":22},"制冷剂在蒸发器后进一步过热",{"key":27,"text":533,"correct":44},"系统的压比减少",{"key":30,"text":535,"correct":44},"压缩机排气温度下降",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":308,"analysis":33},880993,"在净化空调系统中，过滤器设置位置在( )。",[540,542,544,546],{"key":20,"text":541,"correct":22},"将中效空气过滤器集中设置在正压段",{"key":24,"text":543,"correct":44},"将中效空气过滤器集中设置在负压段，保护盘管不受污染",{"key":27,"text":545,"correct":22},"超高效过滤器必须设置在净化空调系统的末端",{"key":30,"text":547,"correct":44},"超高效过滤器可设置在送风管段上",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":47,"analysis":33},880994,"下列哪几项属于被动通风方式？( )",[552,554,556,558],{"key":20,"text":553,"correct":22},"采用补风装置增强自然通风能力",{"key":24,"text":555,"correct":22},"利用太阳能加热排气通道内的空气以提高热压",{"key":27,"text":557,"correct":44},"采用避风风帽",{"key":30,"text":559,"correct":22},"在屋顶上安装无动力风帽",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":60,"analysis":33},880995,"吸收式制冷的优势是( )。",[564,566,568,570],{"key":20,"text":565,"correct":44},"能源利用率高",{"key":24,"text":567,"correct":44},"制冷量大",{"key":27,"text":569,"correct":22},"可实现冷热联供",{"key":30,"text":571,"correct":22},"可实现余热利用",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":135,"analysis":33},880996,"实现吸收式制冷循环的必备部件是( )。",[576,578,580,582],{"key":20,"text":577,"correct":44},"压缩机",{"key":24,"text":579,"correct":22},"冷凝器",{"key":27,"text":581,"correct":22},"节流机构",{"key":30,"text":583,"correct":22},"蒸发器",{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":135,"analysis":33},880997,"设计高层住宅及二类高层建筑时，防烟楼梯间及其前室或合用前室在下述哪些情况下防烟楼梯间可不设防烟设施？( )",[588,590,592,594],{"key":20,"text":589,"correct":44},"前室或合用前室采用自然排烟，其可开启外窗面积足够大时",{"key":24,"text":591,"correct":22},"前室或合用前室利用敞开的阳台进行自然排烟时",{"key":27,"text":593,"correct":22},"前室或合用前室利用凹廊进行自然排烟时",{"key":30,"text":595,"correct":22},"前室或合用前室利用前室有不同朝向可开启外窗自然排烟时",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":47,"analysis":33},880998,"风量控制主要包括( )。",[600,602,604,606],{"key":20,"text":601,"correct":22},"新风量控制",{"key":24,"text":603,"correct":22},"送风量控制",{"key":27,"text":605,"correct":44},"排风量控制",{"key":30,"text":607,"correct":22},"通风机风量控制",{"id":609,"libraryId":5,"type":15,"typeLabel":16,"stem":610,"options":611,"answer":246,"analysis":33},880999,"冷库制冷系统的气密性试验应采用( )进行。",[612,614,616,618],{"key":20,"text":613,"correct":44},"氨气",{"key":24,"text":615,"correct":22},"氮气",{"key":27,"text":617,"correct":22},"干燥空气",{"key":30,"text":619,"correct":44},"氧气",{"id":621,"libraryId":5,"type":15,"typeLabel":16,"stem":622,"options":623,"answer":60,"analysis":33},881000,"下列哪些部位应设置独立的机械加压送风防烟措施？( )",[624,626,628,630],{"key":20,"text":625,"correct":44},"长度超过60m的封闭内走道",{"key":24,"text":627,"correct":44},"面积超过100㎡的地下室",{"key":27,"text":629,"correct":22},"不具备自然排烟条件的防烟楼梯间、消防电梯间前室或合用前室",{"key":30,"text":631,"correct":22},"封闭避难间",[633,637,640,643,646,649],{"id":634,"name":635,"category":7,"favorite":636},1,"领导干部任职前廉政法规知识测试题",92,{"id":638,"name":639,"category":7,"favorite":634},595,"建筑结构与设备",{"id":641,"name":642,"category":7,"favorite":634},715,"招标采购专业知识与法律法规",{"id":644,"name":645,"category":7,"favorite":634},848,"市政方向-通用基础",{"id":647,"name":648,"category":7,"favorite":8},534,"BIM工程师",{"id":650,"name":648,"category":7,"favorite":8},535]