[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-22":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":605},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,22,50,2054,[13,34,46,58,70,82,92,103,115,127,139,151,163,175,187,199,211,223,230,242,254,266,278,290,298,310,318,330,342,354,366,378,390,401,413,422,434,446,458,470,482,494,502,514,526,541,553,566,579,592],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},880901,1,"单选题","低压蒸汽供暖系统水力计算时，错误的做法是( )。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","根据热负荷和推荐流速查表确定管径",false,{"key":24,"text":25,"correct":22},"B","凝结水管管径根据蒸汽放热量查表确定",{"key":27,"text":28,"correct":29},"C","比摩阻等于蒸汽起始压力除以供汽管道最大长度",true,{"key":31,"text":32,"correct":22},"D","局部阻力可根据局部阻力系数乘以动压头计算","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},880902,"某车间采用热风供暖，热媒为30kPa的蒸汽，加热器的理论排水量为200kg\u002Fh，所配疏水阀设计排水量应是下列哪一项？( )",[38,40,42,44],{"key":20,"text":39,"correct":22},"200kg\u002Fh",{"key":24,"text":41,"correct":22},"400kg\u002Fh",{"key":27,"text":43,"correct":29},"600kg\u002Fh",{"key":31,"text":45,"correct":22},"800kg\u002Fh",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},880903,"新风管接到风机盘管回风箱的连接方式的说法中，不正确的是( )。",[50,52,54,56],{"key":20,"text":51,"correct":22},"有可能使回风口过滤器的灰尘重新进入室内",{"key":24,"text":53,"correct":29},"使新风的新鲜度下降，从而使人员需要的新风量增加",{"key":27,"text":55,"correct":22},"新风量受风机盘管运行状况的影响，可能失控",{"key":31,"text":57,"correct":22},"可能使空调能耗增加",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},880904,"当用户供、回水管道压差较小，不能满足水喷射器正常工作所需要的压差时，用户与热网可以采用( )连接。",[62,64,66,68],{"key":20,"text":63,"correct":22},"间接",{"key":24,"text":65,"correct":22},"直接",{"key":27,"text":67,"correct":29},"装混合水泵直接",{"key":31,"text":69,"correct":22},"无混合装置直接",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},880905,"溴化锂吸收式制冷机由( )设备组成。",[74,76,78,80],{"key":20,"text":75,"correct":22},"压缩机、冷凝器、蒸发器、吸收器、溶液热交换器",{"key":24,"text":77,"correct":22},"发生器、冷凝器、蒸发器、吸收器、油分离器",{"key":27,"text":79,"correct":29},"发生器、冷凝器、蒸发器、吸收器、溶液热交换器",{"key":31,"text":81,"correct":22},"贮液器、冷凝器、蒸发器、发生器、溶液热交换器",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":27,"analysis":33},880906,"散热量小于( )的工业建筑，当屋顶离地面平均高度小于或等于8m时，宜采用通风屋顶隔热措施，其通风层长度不宜大于( )，空气层高度宜为20cm左右。",[86,88,90,91],{"key":20,"text":87,"correct":22},"23W\u002F㎡，10m",{"key":24,"text":89,"correct":22},"23W\u002F㎡，15m",{"key":27,"text":33,"correct":29},{"key":31,"text":33,"correct":22},{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":94,"answer":20,"analysis":33},880907,[95,97,99,101],{"key":20,"text":96,"correct":29},"不考虑水泵并联的流量衰减，水泵流量选50t／h",{"key":24,"text":98,"correct":22},"考虑水泵并联的流量衰减10%，水泵流量选56t／h",{"key":27,"text":100,"correct":22},"考虑水泵并联的流量衰减20%，水泵流量选63t／h",{"key":31,"text":102,"correct":22},"考虑水泵并联的流量衰减30%，水泵流量选72t／h",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":105,"options":106,"answer":24,"analysis":33},880908,"处于建筑物内的燃气管道，下列何处属于严禁敷设的地方?( )。",[107,109,111,113],{"key":20,"text":108,"correct":22},"居住建筑的楼梯间",{"key":24,"text":110,"correct":29},"电梯井",{"key":27,"text":112,"correct":22},"建筑给水管道竖井",{"key":31,"text":114,"correct":22},"建筑送风竖井",{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":117,"options":118,"answer":24,"analysis":33},880909,"下列哪类建筑中，空调系统最适合选用带热回收冷水机组？( )",[119,121,123,125],{"key":20,"text":120,"correct":22},"普通办公楼",{"key":24,"text":122,"correct":29},"高级宾馆",{"key":27,"text":124,"correct":22},"体育馆",{"key":31,"text":126,"correct":22},"剧场",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":27,"analysis":33},880910,"下列有关甲、乙类厂房采暖通风设计的说法，哪一项是错误的？",[131,133,135,137],{"key":20,"text":132,"correct":22},"甲、乙类厂房中的空气不应循环使用",{"key":24,"text":134,"correct":22},"甲、乙类厂房内严禁采用电热散热器采暖",{"key":27,"text":136,"correct":29},"甲、乙类厂房用的送风设备与排风设备宜布置在同一通风机房内",{"key":31,"text":138,"correct":22},"甲、乙类厂房排风设备不应与其他房间的送、排风设备布置在同一通风机房内",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":31,"analysis":33},880911,"空调制冷机选型过大一直是一种比较普遍的现象，下列说法中正确的是( )。",[143,145,147,149],{"key":20,"text":144,"correct":22},"设计必须要有一定的安全系数，因此空调设备选型偏大是正常的",{"key":24,"text":146,"correct":22},"空调制冷机容量过大，不会影响空调系统的正常运行，也不会使运行能耗增加",{"key":27,"text":148,"correct":22},"空调制冷机设计选型过大，是由于设计人员采用冷负荷指标估算法造成的",{"key":31,"text":150,"correct":29},"空调制冷机选型过大与基础数据和同时使用系数的选取不当有关",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":31,"analysis":33},880912,"低压燃气管道需要规定允许阻力损失是由于要满足( )。",[155,157,159,161],{"key":20,"text":156,"correct":22},"靠近调压站最近处燃具达到最小压力要求",{"key":24,"text":158,"correct":22},"靠近调压站最近燃具不超过最大允许压力",{"key":27,"text":160,"correct":22},"距调压站最远处燃具达到最小压力要求",{"key":31,"text":162,"correct":29},"距调压站最远处燃具压力波动在允许的范围内",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":27,"analysis":33},880913,"管沟敷设的室外供热管道采用波纹补偿器，在进行水压试验时，管道固定支架受到的作用力是( )。",[167,169,171,173],{"key":20,"text":168,"correct":22},"补偿器弹性反力与活动支架摩擦反力之和",{"key":24,"text":170,"correct":22},"补偿器弹性反力、活动支架摩擦反力与设计工作压力所形成的内压推力之和",{"key":27,"text":172,"correct":29},"1.5倍设计工作压力所形成的内压推力",{"key":31,"text":174,"correct":22},"设计工作压力所形成的内压推力",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":24,"analysis":33},880914,"工程设计中为保证自然通风效果，计算自然通风时一般宜按( )计算。",[179,181,183,185],{"key":20,"text":180,"correct":22},"风压作用",{"key":24,"text":182,"correct":29},"热压作用",{"key":27,"text":184,"correct":22},"热压和风压作用",{"key":31,"text":186,"correct":22},"热压和风压作用最大者",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":24,"analysis":33},880915,"由于( )的限制，在热源温度较高时，应采用双效吸收式制冷机。",[191,193,195,197],{"key":20,"text":192,"correct":22},"溶液沸腾条件",{"key":24,"text":194,"correct":29},"溶液结晶条件",{"key":27,"text":196,"correct":22},"冷却介质温度",{"key":31,"text":198,"correct":22},"冷凝温度",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":31,"analysis":33},880916,"采用直接给水方式的下行上给式系统，最不利配水点通常在建筑物的( )。",[203,205,207,209],{"key":20,"text":204,"correct":22},"最低最远点",{"key":24,"text":206,"correct":22},"最高最近点",{"key":27,"text":208,"correct":22},"最低最近点",{"key":31,"text":210,"correct":29},"最高最远点",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":20,"analysis":33},880917,"低层建筑的消防水箱，其容积一般是贮存( )min的消防用水量。",[215,217,219,221],{"key":20,"text":216,"correct":29},"10",{"key":24,"text":218,"correct":22},"20",{"key":27,"text":220,"correct":22},"30",{"key":31,"text":222,"correct":22},"60",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":225,"answer":24,"analysis":33},880918,[226,227,228,229],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":29},{"key":27,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":27,"analysis":33},880919,"关于选择空气源热泵机组供热的说法，下列哪一项是错误的？",[234,236,238,240],{"key":20,"text":235,"correct":22},"需考虑环境空气温度修正",{"key":24,"text":237,"correct":22},"需考虑融霜频率修正",{"key":27,"text":239,"correct":29},"需考虑室外相对湿度修正",{"key":31,"text":241,"correct":22},"冬季寒冷、潮湿的地区，应根据机组最大供热量与建筑物最大热负荷之差确定辅助加热量",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":27,"analysis":33},880920,"为了使水系统中的冷热盘管调节阀的相对开度与盘管的相对换热量之间呈直线关系，表述正确的应是下列哪一项？( )",[246,248,250,252],{"key":20,"text":247,"correct":22},"调节阀的相对开度与相对流量应呈直线关系",{"key":24,"text":249,"correct":22},"调节阀的相对开度与相对流量应呈快开关系",{"key":27,"text":251,"correct":29},"调节阀的相对开度与相对流量应呈等百分比关系",{"key":31,"text":253,"correct":22},"调节阀的相对开度与相对流量应呈抛物线关系",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":20,"analysis":33},880921,"相同的表面式空气冷却器，在风量不变的情况下，湿工况的空气阻力与干工况空气阻力相比，下列哪一项是正确的？( )",[258,260,262,264],{"key":20,"text":259,"correct":29},"湿工况空气阻力大于干工况空气阻力",{"key":24,"text":261,"correct":22},"湿工况空气阻力等于干工况空气阻力",{"key":27,"text":263,"correct":22},"湿工况空气阻力小于干工况空气阻力",{"key":31,"text":265,"correct":22},"湿工况空气阻力大于或小于干工况空气阻力均有可能",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":27,"analysis":33},880922,"当建筑物采用散热器供暖时，( )的说法是正确的。",[270,272,274,276],{"key":20,"text":271,"correct":22},"幼儿园设置的散热器可以暗装或加防护罩",{"key":24,"text":273,"correct":22},"楼梯间散热器应按每层计算热负荷各自设置",{"key":27,"text":275,"correct":29},"有冻结危险的区域内设置的散热器应单独设置供暖立管",{"key":31,"text":277,"correct":22},"单管串联散热器每组平均温度均相同",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":31,"analysis":33},880923,"室外区域热水供热管网为95℃\u002F70℃热水，室外管网的资用压差大于建筑物供暖系统的压力损失，但静压小于建筑物供暖系统的高度。此时可以考虑采用的连接方式为( )。",[282,284,286,288],{"key":20,"text":283,"correct":22},"设置调节阀的直接连接",{"key":24,"text":285,"correct":22},"设置喷射器的直接连接",{"key":27,"text":287,"correct":22},"设置混水泵的直接连接",{"key":31,"text":289,"correct":29},"通过换热器的间接连接",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":24,"analysis":33},880924,"对于暖风机热风供暖，室内空气的换气次数宜大于或等于( )。",[294,295,296,297],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":29},{"key":27,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":24,"analysis":33},880925,"高层民用建筑中的单元式住宅，在哪种情况下应设防烟楼梯？( )",[302,304,306,308],{"key":20,"text":303,"correct":22},"12层以上",{"key":24,"text":305,"correct":29},"19层及19层以上",{"key":27,"text":307,"correct":22},"11层及11层以上",{"key":31,"text":309,"correct":22},"建筑高度超过23m",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":24,"analysis":33},880926,"设有气体灭火的通信机房和电子计算机房通风换气次数应不小于( )。",[314,315,316,317],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":29},{"key":27,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":27,"analysis":33},880927,"下列关于水阀的选择中，正确的是( )。",[322,324,326,328],{"key":20,"text":323,"correct":22},"可以采用调节阀代替开关阀",{"key":24,"text":325,"correct":22},"两通调节阀宜采用线性特性的",{"key":27,"text":327,"correct":29},"三通调节阀宜采用抛物线特性或线性特性的",{"key":31,"text":329,"correct":22},"为了提高调节性能，阀门宜比管道小一号",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":20,"analysis":33},880928,"关于高层民用建筑的空调系统管道设置的说法中，不正确的是( )。",[334,336,338,340],{"key":20,"text":335,"correct":29},"在设置防火阀的情况下，横向可跨越防火分区",{"key":24,"text":337,"correct":22},"竖向不宜超过5层",{"key":27,"text":339,"correct":22},"竖直风管应设置在管道井内",{"key":31,"text":341,"correct":22},"设有防止回流设施且各层设有自动喷水灭火系统，竖向可超过5层",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":27,"analysis":33},880929,"GB\u002FT14295-2008《空气过滤器》规定中效、高中效和亚高效空气过滤器的测试效率采用( )效率。",[346,348,350,352],{"key":20,"text":347,"correct":22},"大气尘计数法",{"key":24,"text":349,"correct":22},"NaCl固体气溶胶计数法.",{"key":27,"text":351,"correct":29},"KCl固体气溶胶计数法",{"key":31,"text":353,"correct":22},"标准人工尘计重法",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":27,"analysis":33},880930,"我国气调库国家标准规定，气调库的气密性测试要求为( )。",[358,360,362,364],{"key":20,"text":359,"correct":22},"库内限压从186.2Pa下降至127.4Pa的时间≥7min",{"key":24,"text":361,"correct":22},"库内限压从250Pa下降至125Pa的时间≥20min",{"key":27,"text":363,"correct":29},"库内限压从100Pa下降至50Pa的时间≥10min",{"key":31,"text":365,"correct":22},"库内限压从150Pa下降至100Pa的时间≥15min",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":27,"analysis":33},880931,"采用低温送风时，防止送风口结露的条件应是下列哪一项？",[370,372,374,376],{"key":20,"text":371,"correct":22},"降低送风的相对湿度",{"key":24,"text":373,"correct":22},"增加送风管的壁厚",{"key":27,"text":375,"correct":29},"送风口表面温度高于室内露点温度1～2℃",{"key":31,"text":377,"correct":22},"提高送风的相对湿度",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":31,"analysis":33},880932,"非高层建筑的空调系统管道设置的说法中，正确的是( )。",[382,384,386,388],{"key":20,"text":383,"correct":22},"横向应按防火分区设置",{"key":24,"text":385,"correct":22},"竖向不应超过5层",{"key":27,"text":387,"correct":22},"竖直风管不用设置在管道井内",{"key":31,"text":389,"correct":29},"设置防止回流设施或防火阀时，空调管道竖向可超过5层",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":31,"analysis":33},880933,"高压蒸汽管道沿程阻力的比摩阻( )。",[394,395,397,399],{"key":20,"text":33,"correct":22},{"key":24,"text":396,"correct":22},"按照计算管段起始点工作压力条件下的蒸汽密度计算",{"key":27,"text":398,"correct":22},"按照计算管段终点工作压力条件下的蒸汽密度计算",{"key":31,"text":400,"correct":29},"按照计算管段起始点和终点工作压力的平均值条件下的蒸汽密度计算",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":24,"analysis":33},880934,"设计供暖系统的换热设备时，传热温差相同，依据单位换热能力大小选择设备，正确的排列顺序应是下列何项？",[405,407,409,411],{"key":20,"text":406,"correct":22},"汽-水换热时：波节管式＞螺旋螺纹管式＞螺纹扰动盘管式",{"key":24,"text":408,"correct":29},"汽-水换热时：螺旋螺纹管式＞螺纹扰动盘管式＞波节管式",{"key":27,"text":410,"correct":22},"水-水换热时：板式＞螺纹扰动盘管式＞波节管式",{"key":31,"text":412,"correct":22},"水-水换热时：螺纹扰动盘管式＞板式＞波节管式",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":27,"analysis":33},880935,"对于双级蒸气压缩式制冷循环，若按制冷系数最大原则确定中间压力p，可以采用下列哪种方法确定？( )",[417,418,419,420],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":29},{"key":31,"text":421,"correct":22},"按现有高低压级压缩机的容积比确定",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":24,"analysis":33},880936,"某地埋管地源热泵空调系统全年供暖空调动态负荷计算结果表明，全年总释热量与总吸热量之比为1.2，是否需要设置冷却塔？( )",[426,428,430,432],{"key":20,"text":427,"correct":22},"需要",{"key":24,"text":429,"correct":29},"不需要",{"key":27,"text":431,"correct":22},"不确定",{"key":31,"text":433,"correct":22},"地下水径流流速较大时可不设置",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":24,"analysis":33},880937,"舒适性空调房间夏季室内风速，规范规定的数值应是下列哪一项？",[438,440,442,444],{"key":20,"text":439,"correct":22},"≤0.25m\u002Fs",{"key":24,"text":441,"correct":29},"≤0.30m\u002Fs",{"key":27,"text":443,"correct":22},"≤0.35m\u002Fs",{"key":31,"text":445,"correct":22},"≤0.40m\u002Fs",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":20,"analysis":33},880938,"某小区供暖系统为6栋建筑供暖，所有用户均设置带自力式恒温阀的散热器供暖系统，与供热管网直接连接，其中一栋楼热力入口设置电动阀，电动阀开启时段为工作日6：30-18：300应采用下列哪种做法？( )",[450,452,454,456],{"key":20,"text":451,"correct":29},"各用户热力入口设置定压差阀",{"key":24,"text":453,"correct":22},"各用户热力入口设置定流量阀",{"key":27,"text":455,"correct":22},"各用户热力入口设置静态平衡阀",{"key":31,"text":457,"correct":22},"各用户热力入口设置动态电动调节阀",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":20,"analysis":33},880939,"关于降低系统噪声措施的说法中，错误的是( )。",[462,464,466,468],{"key":20,"text":463,"correct":29},"降低噪声最有效的措施是安装消声器",{"key":24,"text":465,"correct":22},"阻性消声器主要用于消减中高频噪声",{"key":27,"text":467,"correct":22},"微穿孔板消声器中没有消声填料，因此适用于净化空调系统",{"key":31,"text":469,"correct":22},"抗性消声器主要用于消减中低频噪声",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":24,"analysis":33},880940,"某工程采用太阳能作为辅助热源的复合式能源系统进行冬季供暖，该工程的总热负荷的计算值为looOkW(其中供暖期必须保证的供热量为800kW)，典型设计日太阳能集热系统的最大供热能力为300kW。下列关于热源装机容量的选择，哪一项是正确的？",[474,476,478,480],{"key":20,"text":475,"correct":22},"loookW",{"key":24,"text":477,"correct":29},"800kW",{"key":27,"text":479,"correct":22},"700kW",{"key":31,"text":481,"correct":22},"500kW",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":27,"analysis":33},880941,"关厂房的排风设备设置和供暖的表述中，下列哪项是错误的？",[486,488,490,492],{"key":20,"text":487,"correct":22},"甲、乙类厂房的排风设备和送风设备不应布置在同一通风机房内",{"key":24,"text":489,"correct":22},"甲、乙类厂房的排风设备不应和其他房间的送风设备布置在同一通风机房内",{"key":27,"text":491,"correct":29},"甲、乙类厂房的排风设备不宜和其他房间的排风设备布置在同一通风机房内",{"key":31,"text":493,"correct":22},"甲、乙类厂房不应采用电热散热器供暖",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":496,"answer":31,"analysis":33},880942,[497,498,499,500],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":31,"text":501,"correct":29},"条件不清，正负压及相应自然通风量无法确定",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":24,"analysis":33},880943,"将某厂房屋顶的颜色由深色变为白色，下列说法中正确的是( )。",[506,508,510,512],{"key":20,"text":507,"correct":22},"该厂房夏季空调冷负荷变大",{"key":24,"text":509,"correct":29},"该厂房夏季空调冷负荷变小",{"key":27,"text":511,"correct":22},"该厂房夏季空调冷负荷不变",{"key":31,"text":513,"correct":22},"该厂房冬季采暖热负荷减少",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":27,"analysis":33},880944,"临界温度离工作温度越近则( )。",[518,520,522,524],{"key":20,"text":519,"correct":22},"节流损失增大，过热损失减小",{"key":24,"text":521,"correct":22},"节流损失减小，过热损失增大",{"key":27,"text":523,"correct":29},"节流损失和过热损失都增大",{"key":31,"text":525,"correct":22},"节流损失和过热损失都减小",{"id":527,"libraryId":5,"type":528,"typeLabel":529,"stem":530,"options":531,"answer":540,"analysis":33},880945,2,"多选题","冷热电三联供系统一般由动力系统、燃气供应系统以及下述哪些系统构成？( )",[532,534,536,538],{"key":20,"text":533,"correct":29},"供配电系统",{"key":24,"text":535,"correct":22},"水系统",{"key":27,"text":537,"correct":29},"余热利用系统",{"key":31,"text":539,"correct":29},"监控系统","ACD",{"id":542,"libraryId":5,"type":528,"typeLabel":529,"stem":543,"options":544,"answer":552,"analysis":33},880946,"在工业建筑中采用暖风机供暖，哪些说法是正确的?( )。",[545,547,548,550],{"key":20,"text":546,"correct":29},"暖风机可独立供暖",{"key":24,"text":33,"correct":29},{"key":27,"text":549,"correct":29},"送风温度在35～70℃之间",{"key":31,"text":551,"correct":22},"不宜与机械送风系统合并使用","ABC",{"id":554,"libraryId":5,"type":528,"typeLabel":529,"stem":555,"options":556,"answer":565,"analysis":33},880947,"关于全面通风，下列说法正确的是( )。",[557,559,561,563],{"key":20,"text":558,"correct":29},"设计全面通风时，宜尽可能采用自然通风，以节约能源和投资。当自然通风达不到卫生或生产要求时，应采用机械通风或自然与机械联合通风",{"key":24,"text":560,"correct":29},"放散热、蒸汽或有害物质的建筑物，当不能采用局部通风，或采用局部通风后达不到卫生标准要求时，应辅以全面通风或采用全面通风",{"key":27,"text":562,"correct":29},"民用建筑的厨房、厕所、浴室等宜采用自然通风或机械通风进行局部通风或全面通风",{"key":31,"text":564,"correct":29},"全面通风可以采用自然通风或机械通风。通风效果取决于通风量和气流组织","ABCD",{"id":567,"libraryId":5,"type":528,"typeLabel":529,"stem":568,"options":569,"answer":578,"analysis":33},880948,"当风量、进风参数及冷冻水供回水温度不变时，以下哪些说法是正确的？",[570,572,574,576],{"key":20,"text":571,"correct":29},"表冷器的析湿系数越大，表明表冷器的机器露点温度越低",{"key":24,"text":573,"correct":22},"表冷器的析湿系数越大，表明表冷器的机器露点温度越高",{"key":27,"text":575,"correct":22},"表冷器的析湿系数越大，表明表冷器的除湿能力越小",{"key":31,"text":577,"correct":29},"表冷器的析湿系数越大，表明表冷器的除湿能力越大","AD",{"id":580,"libraryId":5,"type":528,"typeLabel":529,"stem":581,"options":582,"answer":591,"analysis":33},880949,"对于变风量系统设计，下列叙述正确的是( )。",[583,585,587,589],{"key":20,"text":584,"correct":29},"采用节流型的末端装置时，应在风管内设置静压控制器，根据风管的静压变化来控制风机的总风量",{"key":24,"text":586,"correct":29},"由于风口变风量会影响室内的气流分布，宜采用扩散性能好的送风口",{"key":27,"text":588,"correct":22},"系统的冷热负荷是各区的最大负荷之和",{"key":31,"text":590,"correct":29},"系统的最小风量必须满足气流分布的最低要求，同时必须大于卫生要求的新风量","ABD",{"id":593,"libraryId":5,"type":528,"typeLabel":529,"stem":594,"options":595,"answer":604,"analysis":33},880950,"下列关于过滤器的性能说法，哪几项是错误的?( )。",[596,598,600,602],{"key":20,"text":597,"correct":22},"空气过滤器的性能与面风速有关",{"key":24,"text":599,"correct":29},"过滤器按国家标准效率分类为两个等级",{"key":27,"text":601,"correct":22},"过滤器在工程中多采用计数效率",{"key":31,"text":603,"correct":29},"面风速足够高时，高效过滤器的阻力和风量近似地呈直线关系","BD",[606,609,612,615,618,621],{"id":15,"name":607,"category":7,"favorite":608},"领导干部任职前廉政法规知识测试题",92,{"id":610,"name":611,"category":7,"favorite":15},595,"建筑结构与设备",{"id":613,"name":614,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":616,"name":617,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":619,"name":620,"category":7,"favorite":8},534,"BIM工程师",{"id":622,"name":620,"category":7,"favorite":8},535]