[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-21":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":609},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,21,50,2054,[13,34,46,58,70,82,94,106,118,130,139,151,163,175,187,199,211,223,235,247,259,271,283,293,305,317,329,341,353,365,377,389,401,413,425,437,449,461,473,485,497,505,517,529,541,553,565,577,589,597],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},880851,1,"单选题","乙烯乙二醇水溶液氧化后呈( )。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","酸性",true,{"key":24,"text":25,"correct":26},"B","碱性",false,{"key":28,"text":29,"correct":26},"C","中性",{"key":31,"text":32,"correct":26},"D","不一定","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},880852,"对于消除有害气体的全面通风量计算与( )无关。",[38,40,42,44],{"key":20,"text":39,"correct":22},"送风温度",{"key":24,"text":41,"correct":26},"有害气体允许浓度",{"key":28,"text":43,"correct":26},"有害气体散发量",{"key":31,"text":45,"correct":26},"房间体积",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},880853,"通风系统运行状况下，采用毕托管在一风管的某断面测量气流动压，下列测试状况表明该断面适宜作为测试断面？",[50,52,54,56],{"key":20,"text":51,"correct":26},"动压值为0",{"key":24,"text":53,"correct":26},"动压值为负值",{"key":28,"text":55,"correct":22},"毕托管与风管外壁垂线的夹角为100，动压值最大",{"key":31,"text":57,"correct":26},"毕托管底部与风管中心线的夹角为100，动压值最大",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},880854,"空调工程中常用的冷(热)水机组的选择，当单机制冷量在1000kW以上时，设计时宜选用( )。",[62,64,66,68],{"key":20,"text":63,"correct":26},"往复式冷水机组",{"key":24,"text":65,"correct":26},"螺杆式冷水机组",{"key":28,"text":67,"correct":22},"离心式冷水机组",{"key":31,"text":69,"correct":26},"风冷热泵型冷(热)水机组",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},880855,"除了钢制板型散热器以外的其他散热器，在同等条件下，( )散热器的传热系数K值最小。",[74,76,78,80],{"key":20,"text":75,"correct":26},"下进下出异侧连接",{"key":24,"text":77,"correct":26},"上进下出同侧连接",{"key":28,"text":79,"correct":26},"上进下出异侧连接",{"key":31,"text":81,"correct":22},"下进上出同侧连接",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},880856,"绿色居住建筑住区室外日平均热岛强度不高于( )。",[86,88,90,92],{"key":20,"text":87,"correct":26},"0.5℃",{"key":24,"text":89,"correct":26},"1.0℃",{"key":28,"text":91,"correct":22},"1.5℃",{"key":31,"text":93,"correct":26},"2.0℃",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},880857,"某空调系统的末端装置设计的供／回水温度为7\u002F12℃，末端装置的回水支管上均设有电动二通调节阀。冷水系统为一次泵定流量系统(在总供回水管之间设有旁通管及压差控制的旁通阀)。当压差旁通阀开启进行旁通时，与旁通阀关闭时相比较，正确的变化应为何项？",[98,100,102,104],{"key":20,"text":99,"correct":26},"冷水机组冷水的进出水温差不变",{"key":24,"text":101,"correct":26},"冷水机组冷水的进出水温差加大",{"key":28,"text":103,"correct":22},"冷水机组冷水的进出水温差减小",{"key":31,"text":105,"correct":26},"冷水机组冷水的进水温度升高",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},880858,"某多层住宅采用低温热水地面辐射供暖，确定集中热源的供暖总热量时，应考虑哪些因素？( )",[110,112,114,116],{"key":20,"text":111,"correct":26},"所有房间地面的有效散热量、向下传热损失、通过楼板向上和向下的户间传热量之和",{"key":24,"text":113,"correct":22},"扣除了户间传热量的各户供暖计算负荷总和，加首层地板向下的热损失",{"key":28,"text":115,"correct":26},"所有房间地面的有效散热量、通过楼板向上和向下的户间传热量之和",{"key":31,"text":117,"correct":26},"所有房间地面的有效散热量、向下传热损失、扣除来自上层地板向下的传热损失之和",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},880859,"下述关于活性炭的应用叙述，哪一项是错误的？",[122,124,126,128],{"key":20,"text":123,"correct":26},"活性炭适宜于对芳香族有机溶剂蒸气的吸附",{"key":24,"text":125,"correct":22},"细孔活性炭不适用于吸附低浓度挥发性蒸气",{"key":28,"text":127,"correct":26},"当用活性炭吸附含尘浓度大于10mg\u002Fm3的有害气体时，必须采取过滤等预处理措施",{"key":31,"text":129,"correct":26},"当有害气体的浓度≤100ppm时，活性炭吸附装置可不设计再生回收装置",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},880860,"下列哪项有害物浓度不符合室内空气质量标准的规定？( )",[134,136,137,138],{"key":20,"text":135,"correct":26},"二氧化碳，0.10%，日平均值",{"key":24,"text":33,"correct":26},{"key":28,"text":33,"correct":26},{"key":31,"text":33,"correct":22},{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":24,"analysis":33},880861,"某高层建筑中，当首层的排水支管连接在排水横干管上时，其连接点距立管底部下游水平距离( )。",[143,145,147,149],{"key":20,"text":144,"correct":26},"不宜小于3.0m，且不得小于1.5m",{"key":24,"text":146,"correct":22},"应大于3.0m",{"key":28,"text":148,"correct":26},"应大于等于1.5m，不宜大于3.0m",{"key":31,"text":150,"correct":26},"应小于等于3.0m",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":24,"analysis":33},880862,"确定容积式加热器的设计小时供热量的依据是( )。",[155,157,159,161],{"key":20,"text":156,"correct":26},"热水系统的设计小时耗热量",{"key":24,"text":158,"correct":22},"热水系统的设计小时耗热量减去加热器的贮热量",{"key":28,"text":160,"correct":26},"热水系统的设计小时耗热量减去加热器贮热量的一半",{"key":31,"text":162,"correct":26},"按照设计秒流量计算的热水系统耗热量",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":20,"analysis":33},880863,"哪一种地源热泵系统的设计要强调在计算周期内系统的总释热量宜与其总吸热量相平衡？( )",[167,169,171,173],{"key":20,"text":168,"correct":22},"地埋管热泵系统",{"key":24,"text":170,"correct":26},"地下水热泵系统",{"key":28,"text":172,"correct":26},"地表水热泵系统",{"key":31,"text":174,"correct":26},"所有地源热泵系统",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":20,"analysis":33},880864,"按负担室内负荷所用的介质种类分类，不包括( )。",[179,181,183,185],{"key":20,"text":180,"correct":22},"直流式系统",{"key":24,"text":182,"correct":26},"全空气系统",{"key":28,"text":184,"correct":26},"全水系统",{"key":31,"text":186,"correct":26},"制冷剂系统",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":20,"analysis":33},880865,"分户热计量系统中，造成垂直失调的主要原因是( )。",[191,193,195,197],{"key":20,"text":192,"correct":22},"自然循环作用压力",{"key":24,"text":194,"correct":26},"入口的资用压力",{"key":28,"text":196,"correct":26},"系统的循环压力",{"key":31,"text":198,"correct":26},"系统管径的大小",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":28,"analysis":33},880866,"下列除尘器具有深层过滤作用的是( )。",[203,205,207,209],{"key":20,"text":204,"correct":26},"重力沉降室",{"key":24,"text":206,"correct":26},"旋风除尘器",{"key":28,"text":208,"correct":22},"袋式除尘器",{"key":31,"text":210,"correct":26},"静电除尘器",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":31,"analysis":33},880867,"建筑物全面排风系统吸风口仅用于排除余热和余湿时，吸风口设置妻求哪个是正确的？( )",[215,217,219,221],{"key":20,"text":216,"correct":26},"位置无特殊要求",{"key":24,"text":218,"correct":26},"应设于房间上部",{"key":28,"text":220,"correct":26},"上缘至顶棚平面的距离不大于0.5m",{"key":31,"text":222,"correct":22},"上缘至顶棚平面的距离不大于0.4m",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":28,"analysis":33},880868,"确定管道活动支架最大间距的原则，是取( )。",[227,229,231,233],{"key":20,"text":228,"correct":26},"管道强度计算允许值",{"key":24,"text":230,"correct":26},"管道刚度计算允许值",{"key":28,"text":232,"correct":22},"管道强度计算和刚度计算允许值两者中的较小值",{"key":31,"text":234,"correct":26},"管道强度计算和刚度计算允许值两者中的较大值",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":28,"analysis":33},880869,"关于维持正压房间的空调冷负荷，表述正确的应是下列哪一项？( )",[239,241,243,245],{"key":20,"text":240,"correct":26},"空调房间的夏季冷负荷中包括了新风负荷，故房间的冷负荷比房间得热量大",{"key":24,"text":242,"correct":26},"空调系统的冷负荷就是空调房间的得热量",{"key":28,"text":244,"correct":22},"空调房间的冷负荷最终就是由对流换热量组成的",{"key":31,"text":246,"correct":26},"空调房间的瞬时辐射得热量与对流得热量之和为房间的冷负荷",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":28,"analysis":33},880870,"关于防烟分区的设置，下列说法错误的是( )。",[251,253,255,257],{"key":20,"text":252,"correct":26},"不设排烟设施的房间(包括地下室)和走道，不划分防烟分区",{"key":24,"text":254,"correct":26},"防烟分区不应跨越防火分区",{"key":28,"text":256,"correct":22},"每个防烟分区的面积，对于高层民用建筑和其他建筑(含地下建筑和人防工程)，其建筑面积不宜大于400㎡",{"key":31,"text":258,"correct":26},"对有特殊用途的场所，如地下室、防烟楼梯间、消防电梯、避难层(间)等，应单独划分防烟分区",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":24,"analysis":33},880871,"下列哪类建筑的外墙传热系数限值与其热惰性有关？( )",[263,265,267,269],{"key":20,"text":264,"correct":26},"夏热冬暖地区公共建筑",{"key":24,"text":266,"correct":22},"夏热冬冷地区居住建筑",{"key":28,"text":268,"correct":26},"寒冷地区居住建筑",{"key":31,"text":270,"correct":26},"严寒地区公共建筑",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":20,"analysis":33},880872,"计算平均小时平均秒流量的用途是( )。",[275,277,279,281],{"key":20,"text":276,"correct":22},"确定居住小区配套设施的给水管道直径",{"key":24,"text":278,"correct":26},"确定居住小区",{"key":28,"text":280,"correct":26},"确定生活用水贮水池容积",{"key":31,"text":282,"correct":26},"确定加压给水系统高位水箱容积",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":31,"analysis":33},880873,"地源热泵系统作为一种利用可再生能源的空调冷热源系统，有多种形式。试问下列哪个系统不属于地源热泵系统范畴？",[287,288,289,291],{"key":20,"text":168,"correct":26},{"key":24,"text":170,"correct":26},{"key":28,"text":290,"correct":26},"江水源热泵系统",{"key":31,"text":292,"correct":22},"水环热泵系统",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":24,"analysis":33},880874,"有一两级除尘系统，设计风量为300000m3\u002Fh，烟气温度为140℃，当地大气压力为84.6kPa，重力除尘器入口含尘浓度为30g\u002Fm3，粉尘排放浓度为50mg\u002Fm3(标态)，问除尘系统应达到的除尘总效率是多少？",[297,299,301,303],{"key":20,"text":298,"correct":26},"99.83%",{"key":24,"text":300,"correct":22},"99.91%",{"key":28,"text":302,"correct":26},"99.89%",{"key":31,"text":304,"correct":26},"99.87%",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":28,"analysis":33},880875,"关于溴化锂吸收式机组的说法，下列哪一项是错误的？",[309,311,313,315],{"key":20,"text":310,"correct":26},"制冷量相同时，溴化锂吸收式机组比离心式冷水机组冷却水量大",{"key":24,"text":312,"correct":26},"冷水出口温度上升时，机组热力系数增加",{"key":28,"text":314,"correct":22},"当有足够电力供应时，宜采用专配锅炉为驱动热源的溴化锂吸收式机组",{"key":31,"text":316,"correct":26},"冷却水温度过低时，机组中浓溶液可能产生结晶",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":24,"analysis":33},880876,"关于水力平衡阀的设置和选择，符合规定的是( )。",[321,323,325,327],{"key":20,"text":322,"correct":26},"热力站出口总管上应串联设置自力式流量控制阀",{"key":24,"text":324,"correct":22},"定流量水系统的各热力入口可设置静态水力平衡阀",{"key":28,"text":326,"correct":26},"自力式控制阀的阀权度应保持在0.3～1",{"key":31,"text":328,"correct":26},"变流量水系统的各热力入口可设置自力式控制阀",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":31,"analysis":33},880877,"在风机盘管十新风系统中，新风机组为定风量系统，各房间的设计新风量均相同，各房间的新风支管均无风阀。关于不同的新风接入室内方法的表述中，下列哪一项是错误的？",[333,335,337,339],{"key":20,"text":334,"correct":26},"新风接入风机盘管回风，口处，风机盘管高速运行房间的新风多于低速运行的房间",{"key":24,"text":336,"correct":26},"新风接人风机盘管送风管处，风机盘管停机的房间送入的新风量最大",{"key":28,"text":338,"correct":26},"新风单独接人室内，送入的新风量不随风机盘管的运行与否而改变",{"key":31,"text":340,"correct":22},"三种新风接入方法送入的新风量完全一样",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":28,"analysis":33},880878,"某办公楼集中空调的冷源采用3台电制冷机组并联工作，冷水循环泵和冷水机组为公用集管连接方式，当楼内风机盘管的电动水阀自动关闭较多时，采用停止1台或2台机组进行调节，正确的控制程序应是下列哪一项？( )",[345,347,349,351],{"key":20,"text":346,"correct":26},"仅关闭应停止运行的制冷机的电器开关",{"key":24,"text":348,"correct":26},"关闭应停止运行的制冷机以及对应的冷水循环泵、冷却水泵和冷却塔风机的电路开关",{"key":28,"text":350,"correct":22},"除执行B项外，还关闭停止运行制冷机的进出水路阀门",{"key":31,"text":352,"correct":26},"关闭应停止运行的制冷机以及对应的冷水循环泵、冷却水泵的电路开关",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":28,"analysis":33},880879,"水冷式电动压缩冷水机组，综合部分负荷性能系数(IPI.V)的计算组成中，其最大权重百分比值所对应的负荷百分比应为下列哪一项？",[357,359,361,363],{"key":20,"text":358,"correct":26},"100%",{"key":24,"text":360,"correct":26},"75%",{"key":28,"text":362,"correct":22},"50%",{"key":31,"text":364,"correct":26},"25%",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":20,"analysis":33},880880,"更容易发挥VRV节能效果的空调系统，是下列哪一项？",[369,371,373,375],{"key":20,"text":370,"correct":22},"宾馆连续运行的系统",{"key":24,"text":372,"correct":26},"办公楼间歇运行的系统",{"key":28,"text":374,"correct":26},"频繁启停的系统",{"key":31,"text":376,"correct":26},"需要较长输送距离的大型建筑的空调系统",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":24,"analysis":33},880881,"辐射顶板供冷时，保证辐射顶板正常运行的水温控制，应是下列哪一项？( )",[381,383,385,387],{"key":20,"text":382,"correct":26},"应控制出水温度",{"key":24,"text":384,"correct":22},"应控制进水温度",{"key":28,"text":386,"correct":26},"应控制进出水温差",{"key":31,"text":388,"correct":26},"不控制水温",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":28,"analysis":33},880882,"关于组合式空调机组的表冷器的说法，下列哪一项是错误的？( )",[393,395,397,399],{"key":20,"text":394,"correct":26},"可实现等湿冷却",{"key":24,"text":396,"correct":26},"可实现减湿冷却",{"key":28,"text":398,"correct":22},"干式冷却换热强度高于减湿冷却",{"key":31,"text":400,"correct":26},"冷水进水温度应比空气出口干球温度至少低3.5℃",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":31,"analysis":33},880883,"关于建筑中可再生能源的利用，不符合《绿建标准》规定的是( )。",[405,407,409,411],{"key":20,"text":406,"correct":26},"居住建筑1\u002F4的住户安装太阳能热水器",{"key":24,"text":408,"correct":26},"太阳能光伏板发电量占商场建筑总用电量的2%",{"key":28,"text":410,"correct":26},"酒店建筑中可再生能源产生的热水量不低于建筑生活热水消耗量的10%",{"key":31,"text":412,"correct":22},"居住建筑可再生能源发电量不低于公共区域总用电量的5%",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":31,"analysis":33},880884,"围护结构的热惰性系数，与( )无关。",[417,419,421,423],{"key":20,"text":418,"correct":26},"热导率",{"key":24,"text":420,"correct":26},"厚度",{"key":28,"text":422,"correct":26},"蓄热系数",{"key":31,"text":424,"correct":22},"内外表面传热系数",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":20,"analysis":33},880885,"地源热泵系统存在的主要问题和特点中，下列哪一项是错误的？( )",[429,431,433,435],{"key":20,"text":430,"correct":22},"运行费高",{"key":24,"text":432,"correct":26},"土壤温度场恢复问题",{"key":28,"text":434,"correct":26},"一旦泄漏，维修不便",{"key":31,"text":436,"correct":26},"当土壤λ值小时，地埋管换热器面积大",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":28,"analysis":33},880886,"制冷剂中破坏大气臭氧层的组成原子是( )。",[441,443,445,447],{"key":20,"text":442,"correct":26},"氢",{"key":24,"text":444,"correct":26},"氟",{"key":28,"text":446,"correct":22},"氯",{"key":31,"text":448,"correct":26},"碳",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":20,"analysis":33},880887,"下列关于夏季室内空调温度选取的方法中，错误的是( )。",[453,455,457,459],{"key":20,"text":454,"correct":22},"某部委办公楼夏季空调运行温度设定为25.℃",{"key":24,"text":456,"correct":26},"旅馆客房的夏季空调计算温度按27℃计算",{"key":28,"text":458,"correct":26},"美术馆善本库的夏季空调计算温度按23℃计算",{"key":31,"text":460,"correct":26},"医院病房的夏季空调计算温度按26℃计算",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":20,"analysis":33},880888,"以下关于冰蓄冷的看法，哪一项是错误的？",[465,467,469,471],{"key":20,"text":466,"correct":22},"冰蓄冷系统节能量的计算方法和其他制冷节能技术的计算方法相同",{"key":24,"text":468,"correct":26},"冰蓄冷系统节能量的计算方法和其他制冷节能技术的计‘算方法不同",{"key":28,"text":470,"correct":26},"采用冰蓄冷系统的用户侧的实际用电量会增加",{"key":31,"text":472,"correct":26},"采用冰蓄冷系统能够移峰填谷，可以减少电厂的发电设备增加，同时有发电，一已有发电设备处于高效运行，广义上属于节能减排技术",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":28,"analysis":33},880889,"确定建筑生活热水系统热水加热器的热水设计水温时，应从节能、防结垢、使用管道和设备规格等因素考虑，一般适宜的热水温度应为下列哪一项？( )",[477,479,481,483],{"key":20,"text":478,"correct":26},"30～39℃",{"key":24,"text":480,"correct":26},"40～49℃",{"key":28,"text":482,"correct":22},"50～60℃",{"key":31,"text":484,"correct":26},"61～70℃",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":24,"analysis":33},880890,"围护结构的最小传热阻计算公式，不适用于下列哪一项？( )",[489,491,493,495],{"key":20,"text":490,"correct":26},"外墙",{"key":24,"text":492,"correct":22},"外窗",{"key":28,"text":494,"correct":26},"屋顶",{"key":31,"text":496,"correct":26},"地面",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":24,"analysis":33},880891,"R22，R134a的国际单位制的图或表，一般规定其0℃时饱和液体的比焓h′和比熵s′分别为( )。",[501,502,503,504],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":26},{"key":31,"text":33,"correct":26},{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":28,"analysis":33},880892,"热水供暖系统中的重力作用压头与下列哪一项无关？( )",[509,511,513,515],{"key":20,"text":510,"correct":26},"锅炉安装高度",{"key":24,"text":512,"correct":26},"散热器安装高度",{"key":28,"text":514,"correct":22},"膨胀水箱安装高度",{"key":31,"text":516,"correct":26},"室内干管安装高度",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":28,"analysis":33},880893,"面风速不大的情况下，高效空气过滤器风量为800m3\u002Fh，粗阻力为200Pa，同一过滤器当风量为400m3\u002Fh时，其初阻力近似值应是下列哪一项？",[521,523,525,527],{"key":20,"text":522,"correct":26},"50Pa",{"key":24,"text":524,"correct":26},"80Pa",{"key":28,"text":526,"correct":22},"100Pa",{"key":31,"text":528,"correct":26},"120Pa",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":31,"analysis":33},880894,"对冷库隔热材料的要求中哪项是不准确的？( )",[533,535,537,539],{"key":20,"text":534,"correct":26},"热导率宜小",{"key":24,"text":536,"correct":26},"宜为难燃或不燃材料，且不易变质",{"key":28,"text":538,"correct":26},"易于现场施工",{"key":31,"text":540,"correct":22},"块状材料必须具有防辐射面层",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":20,"analysis":33},880895,"关于袋式除尘器清灰的作用，错误的是( )。",[545,547,549,551],{"key":20,"text":546,"correct":22},"彻底清除滤料上的积灰",{"key":24,"text":548,"correct":26},"减小运行阻力",{"key":28,"text":550,"correct":26},"保证过滤效率",{"key":31,"text":552,"correct":26},"保证处理风量",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":20,"analysis":33},880896,"地源热泵系统根据地热能交换系统形式的不同，分为( )。",[557,559,561,563],{"key":20,"text":558,"correct":22},"地埋管地源热泵系统、地下水地源热泵系统和地表水地源热泵系统",{"key":24,"text":560,"correct":26},"地埋管地源热泵系统、水环式地源热泵系统",{"key":28,"text":562,"correct":26},"地下环路式地源热泵系统、地表水地源热泵系统",{"key":31,"text":564,"correct":26},"地埋管地源热泵系统、地下水地源热泵系统",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":31,"analysis":33},880897,"一般送排风系统和，除尘通风系统的各个并联环路压力损失的相对差额有一定的要求，下列哪一项表述是正确的？，( )",[569,571,573,575],{"key":20,"text":570,"correct":26},"一般送排风系统5%，除尘通风系统10%",{"key":24,"text":572,"correct":26},"一般送排风系统和除尘通风系统均为10%",{"key":28,"text":574,"correct":26},"一般送排风系统10%，除尘通风系统15%",{"key":31,"text":576,"correct":22},"一般送排风系统15%，除尘通风系统10%",{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":20,"analysis":33},880898,"机械循环热水供暖系统的经济平均比摩阻为( )Pa／m。",[581,583,585,587],{"key":20,"text":582,"correct":22},"60～120",{"key":24,"text":584,"correct":26},"50～100",{"key":28,"text":586,"correct":26},"70～130",{"key":31,"text":588,"correct":26},"50～150",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":28,"analysis":33},880899,"氨制冷机房的事故排风量按( )计算。",[593,594,595,596],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":26},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":26},{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":24,"analysis":33},880900,"关于低温热水地面辐射供暖系统的压力试验，下列哪个说法是正确的？( )",[601,603,605,607],{"key":20,"text":602,"correct":26},"稳压时间应为30min",{"key":24,"text":604,"correct":22},"试验压力不应小于0.6MPa",{"key":28,"text":606,"correct":26},"有冻结危险处应进行气压试验",{"key":31,"text":608,"correct":26},"宜进行两次试压",[610,613,616,619,622,625],{"id":15,"name":611,"category":7,"favorite":612},"领导干部任职前廉政法规知识测试题",92,{"id":614,"name":615,"category":7,"favorite":15},595,"建筑结构与设备",{"id":617,"name":618,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":620,"name":621,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":623,"name":624,"category":7,"favorite":8},534,"BIM工程师",{"id":626,"name":624,"category":7,"favorite":8},535]