[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-20":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":620},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,20,50,2054,[13,35,49,61,73,85,97,110,122,134,147,160,172,184,196,208,220,231,243,255,267,279,291,302,314,326,338,350,362,374,386,398,410,422,434,446,458,470,481,493,505,517,529,537,549,561,573,584,596,608],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},880801,2,"多选题","制冷剂含有水分将导致制冷系统出现( )。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","冰塞",true,{"key":24,"text":25,"correct":22},"B","使润滑油呈酸性，破坏电动机绝缘",{"key":27,"text":28,"correct":22},"C","制冷效率降低",{"key":30,"text":31,"correct":32},"D","压缩机回油困难",false,"ABC","",{"id":36,"libraryId":5,"type":37,"typeLabel":38,"stem":39,"options":40,"answer":20,"analysis":34},880802,1,"单选题","采用氨制冷剂的制冷系统，下列说法错误的是( )。",[41,43,45,47],{"key":20,"text":42,"correct":22},"制冷机房可布置在地下室、生产厂房、高层民用建筑的地下层中",{"key":24,"text":44,"correct":32},"作为空调系统冷源时，应采用水-空气间接供冷方式",{"key":27,"text":46,"correct":32},"制冷机房高度不低于4.8m",{"key":30,"text":48,"correct":32},"保冷材料应为不燃或难燃(B1级)材料",{"id":50,"libraryId":5,"type":37,"typeLabel":38,"stem":51,"options":52,"answer":30,"analysis":34},880803,"用皮托管与倾斜式微压计测定管道内气体流动参数，下列哪一项不能直接读得结果？( )",[53,55,57,59],{"key":20,"text":54,"correct":32},"全压",{"key":24,"text":56,"correct":32},"静压",{"key":27,"text":58,"correct":32},"动压",{"key":30,"text":60,"correct":22},"流量",{"id":62,"libraryId":5,"type":37,"typeLabel":38,"stem":63,"options":64,"answer":27,"analysis":34},880804,"对于高压蒸汽系统疏水器后至凝结水箱(或二次蒸发箱)之间的蒸汽凝结水管，以下哪一种概念是错误的？( )",[65,67,69,71],{"key":20,"text":66,"correct":32},"应按照汽水乳状体进行计算",{"key":24,"text":68,"correct":32},"相同管径的凝结水流量，开式系统小于闭式系统",{"key":27,"text":70,"correct":22},"相同管径的凝结水流量，压力越大流量越大",{"key":30,"text":72,"correct":32},"管径相同的凝结水管，流量越大压力损失越大",{"id":74,"libraryId":5,"type":37,"typeLabel":38,"stem":75,"options":76,"answer":20,"analysis":34},880805,"高层建筑中安装在吊顶内的排烟管道隔热层，应选用下列哪一种材料？( )",[77,79,81,83],{"key":20,"text":78,"correct":22},"超细玻璃棉",{"key":24,"text":80,"correct":32},"发泡橡塑",{"key":27,"text":82,"correct":32},"聚苯乙烯塑料板",{"key":30,"text":84,"correct":32},"聚氨酯泡沫塑料",{"id":86,"libraryId":5,"type":15,"typeLabel":16,"stem":87,"options":88,"answer":96,"analysis":34},880806,"某办公建筑选用若干空调制冷设备，下列哪几项表述不符合现行国家标准规定？( )",[89,91,93,95],{"key":20,"text":90,"correct":22},"1台螺杆式空气源热泵冷(热)水机组，名义工况的制冷量为400kW，输入功率为146kW",{"key":24,"text":92,"correct":22},"1台离心式冷水机组，名义工况的制冷量为1250kW，输入功率为250kW",{"key":27,"text":94,"correct":32},"1台风冷式接风管的屋顶式空调机组，能效比(EER)为4级",{"key":30,"text":34,"correct":22},"ABD",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":109,"analysis":34},880807,"封闭空气间层热阻值与下列哪些因素有关？( )",[101,103,105,107],{"key":20,"text":102,"correct":22},"空气间层的位置",{"key":24,"text":104,"correct":22},"空气间层的厚度",{"key":27,"text":106,"correct":22},"间层表面材料的黑度",{"key":30,"text":108,"correct":22},"热流状态","ABCD",{"id":111,"libraryId":5,"type":37,"typeLabel":38,"stem":112,"options":113,"answer":24,"analysis":34},880808,"在进行高层民用建筑室内消火栓布置时，其间距应( )。",[114,116,118,120],{"key":20,"text":115,"correct":32},"不大于25m",{"key":24,"text":117,"correct":22},"按计算确定，且不应大于30m",{"key":27,"text":119,"correct":32},"不大于30m",{"key":30,"text":121,"correct":32},"不大于50m",{"id":123,"libraryId":5,"type":37,"typeLabel":38,"stem":124,"options":125,"answer":27,"analysis":34},880809,"室外给水管道的管顶最小覆土深度( )。",[126,128,130,132],{"key":20,"text":127,"correct":32},"不得小于土壤冰冻深度",{"key":24,"text":129,"correct":32},"不宜小于0.7m",{"key":27,"text":131,"correct":22},"不得小于土壤冰冻线以下0.15m",{"key":30,"text":133,"correct":32},"不宜小于0.85m",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":146,"analysis":34},880810,"某空调冷水系统两根管径不同的管道，当管内流速相同时，关于单位长度管道沿程阻力R的说法错误的应是下列哪几项？",[138,140,142,144],{"key":20,"text":139,"correct":22},"小管径的R值小",{"key":24,"text":141,"correct":32},"大管径的R值小",{"key":27,"text":143,"correct":22},"两种管径的R值相同",{"key":30,"text":145,"correct":32},"小管径的R值大","AC",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":159,"analysis":34},880811,"对自然通风的表述，下列哪几项是正确的？( )",[151,153,155,157],{"key":20,"text":152,"correct":22},"建筑迎风面为正压区，原因在于滞留区的静压高于大气压",{"key":24,"text":154,"correct":32},"建筑物中和界余压为零，中和界以上气流由内向外流动，中和界以下气流由外向内流动",{"key":27,"text":156,"correct":22},"工作区设置机械排风，造成建筑物中和界上移",{"key":30,"text":158,"correct":22},"设置机械送风，造成建筑物中和界下降","ACD",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":96,"analysis":34},880812,"供暖系统干管按照0.003的坡度敷设的应用范围为( )。",[164,166,168,170],{"key":20,"text":165,"correct":22},"热水供暖系统的供水和回水管",{"key":24,"text":167,"correct":22},"汽水同向的蒸汽管",{"key":27,"text":169,"correct":32},"汽水逆向的蒸汽管",{"key":30,"text":171,"correct":22},"蒸汽凝结水管",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":33,"analysis":34},880813,"空调水系统过滤器的说法中，正确的是( )。",[176,178,180,182],{"key":20,"text":177,"correct":22},"空气源热泵式空调冷水机组的定压管应接在水泵入口与过滤器之间",{"key":24,"text":179,"correct":22},"过滤网的有效流通面积应等于接管流通面积的3.5～4倍",{"key":27,"text":181,"correct":22},"水泵前的Y型过滤器的孔径宜为4mm",{"key":30,"text":183,"correct":32},"风机盘管的Y型过滤器的孔径宜为3mm",{"id":185,"libraryId":5,"type":37,"typeLabel":38,"stem":186,"options":187,"answer":30,"analysis":34},880814,"空调冷水系统补水泵的小时流量宜为( )。",[188,190,192,194],{"key":20,"text":189,"correct":32},"冷水循环流量的2%",{"key":24,"text":191,"correct":32},"冷水循环流量的1.5%",{"key":27,"text":193,"correct":32},"冷水循环流量的1%",{"key":30,"text":195,"correct":22},"空调冷水系统水容量的5%～10%",{"id":197,"libraryId":5,"type":37,"typeLabel":38,"stem":198,"options":199,"answer":27,"analysis":34},880815,"为了获取较低的蒸发温度，可采用单一制冷剂的( )，这样可避免因压缩比过高而损坏压缩机。",[200,202,204,206],{"key":20,"text":201,"correct":32},"单级压缩式制冷循环",{"key":24,"text":203,"correct":32},"复叠式制冷循环",{"key":27,"text":205,"correct":22},"双级压缩式制冷循环",{"key":30,"text":207,"correct":32},"回热循环",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":33,"analysis":34},880816,"与排水设计秒流量相关的因素有( )。",[212,214,216,218],{"key":20,"text":213,"correct":22},"计算管段的卫生器具排水当量",{"key":24,"text":215,"correct":22},"计算管段上最大一个卫生器具的排水流量",{"key":27,"text":217,"correct":22},"建筑物的用途",{"key":30,"text":219,"correct":32},"建筑物所在地",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":222,"answer":33,"analysis":34},880817,[223,225,227,229],{"key":20,"text":224,"correct":22},"900",{"key":24,"text":226,"correct":22},"700",{"key":27,"text":228,"correct":22},"600",{"key":30,"text":230,"correct":32},"1400",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":33,"analysis":34},880818,"在公共建筑围护结构热工性能权衡判断的空调能耗模拟计算时，参照建筑的下列哪些参数应与所设计建筑相同？( )",[235,237,239,241],{"key":20,"text":236,"correct":22},"形状",{"key":24,"text":238,"correct":22},"朝向",{"key":27,"text":240,"correct":22},"室内空调参数",{"key":30,"text":242,"correct":32},"窗墙面积比",{"id":244,"libraryId":5,"type":37,"typeLabel":38,"stem":245,"options":246,"answer":30,"analysis":34},880819,"关于冷库隔汽层和隔潮层的构造设置要求与做法，下列哪项是错误的?( )。",[247,249,251,253],{"key":20,"text":248,"correct":32},"库房外墙的隔汽层应与地面隔热层上的隔汽层搭接",{"key":24,"text":250,"correct":32},"楼面、地面的隔热层四周应做防水层或隔汽层",{"key":27,"text":252,"correct":32},"隔墙隔热层底部应做防潮层，且应在其热侧上翻铺0.12m",{"key":30,"text":254,"correct":22},"围护结构两侧设计温差大于5℃时应做隔汽层",{"id":256,"libraryId":5,"type":37,"typeLabel":38,"stem":257,"options":258,"answer":27,"analysis":34},880820,"关于二次泵变流量水系统的说法，下列说法错误的是哪一项？",[259,261,263,265],{"key":20,"text":260,"correct":32},"冷源侧总流量利用旁通管保持流量平衡",{"key":24,"text":262,"correct":32},"用户侧流量利用二次泵调节，保持流量平衡",{"key":27,"text":264,"correct":22},"旁通管管径应该小于总管管径",{"key":30,"text":266,"correct":32},"旁通管上不应该设置阀门",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":33,"analysis":34},880821,"空间较大的公共建筑和室温波动幅度允许超过±1℃的高大厂房，宜采用( )送风。",[271,273,275,277],{"key":20,"text":272,"correct":22},"喷口",{"key":24,"text":274,"correct":22},"旋流风口",{"key":27,"text":276,"correct":22},"送风口下部",{"key":30,"text":278,"correct":32},"散流器",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":109,"analysis":34},880822,"下列情况中，哪些需要单独设置排风系统?( )。",[283,285,287,289],{"key":20,"text":284,"correct":22},"散发铅蒸汽的房间",{"key":24,"text":286,"correct":22},"药品库",{"key":27,"text":288,"correct":22},"有卫生防疫的要求时",{"key":30,"text":290,"correct":22},"放映室",{"id":292,"libraryId":5,"type":37,"typeLabel":38,"stem":34,"options":293,"answer":27,"analysis":34},880823,[294,296,298,300],{"key":20,"text":295,"correct":32},"通过围护结构传人的热量",{"key":24,"text":297,"correct":32},"室内人员的显热量与照明、设备散热量之和",{"key":27,"text":299,"correct":22},"室内的余热量",{"key":30,"text":301,"correct":32},"室内的余热量和新风耗冷量之和",{"id":303,"libraryId":5,"type":37,"typeLabel":38,"stem":304,"options":305,"answer":24,"analysis":34},880824,"按冷库的库温范围和要求，冷库可分为( )。",[306,308,310,312],{"key":20,"text":307,"correct":32},"高温冷库、低温冷库",{"key":24,"text":309,"correct":22},"高温冷库、低温冷库、变温冷库",{"key":27,"text":311,"correct":32},"冷却物冷藏库、冻结物冷藏库",{"key":30,"text":313,"correct":32},"-18℃库、-23℃库",{"id":315,"libraryId":5,"type":37,"typeLabel":38,"stem":316,"options":317,"answer":20,"analysis":34},880825,"在人防工程内，需设置排烟设施的部位，其室内地坪至顶棚的高度不超过6m时，每个防烟分区的建筑面积不应大于下列哪一个数值？( )",[318,320,322,324],{"key":20,"text":319,"correct":22},"500㎡",{"key":24,"text":321,"correct":32},"600㎡",{"key":27,"text":323,"correct":32},"1000㎡",{"key":30,"text":325,"correct":32},"2000㎡",{"id":327,"libraryId":5,"type":37,"typeLabel":38,"stem":328,"options":329,"answer":30,"analysis":34},880826,"使用燃气冷热电三联供系统的年平均综合利用率应大于( )。",[330,332,334,336],{"key":20,"text":331,"correct":32},"85%",{"key":24,"text":333,"correct":32},"80%",{"key":27,"text":335,"correct":32},"75%",{"key":30,"text":337,"correct":22},"70%",{"id":339,"libraryId":5,"type":37,"typeLabel":38,"stem":340,"options":341,"answer":30,"analysis":34},880827,"全空气空调系统夏季采用新风冷却时，通常用来判断新风冷却工况的参数是( )。",[342,344,346,348],{"key":20,"text":343,"correct":32},"新风温度",{"key":24,"text":345,"correct":32},"新风比焓",{"key":27,"text":347,"correct":32},"新风与回风的温差",{"key":30,"text":349,"correct":22},"新风与回风的比焓差",{"id":351,"libraryId":5,"type":37,"typeLabel":38,"stem":352,"options":353,"answer":27,"analysis":34},880828,"在消声设计计算中，对于直风管，当风速小于( )时，可不计算气流再生噪声；风速大于( )时，可不计算噪声自然衰减量。",[354,356,358,360],{"key":20,"text":355,"correct":32},"3m\u002Fs；5m\u002Fs",{"key":24,"text":357,"correct":32},"4m\u002Fs；6m\u002Fs",{"key":27,"text":359,"correct":22},"5m\u002Fs；8m\u002Fs",{"key":30,"text":361,"correct":32},"6m\u002Fs；10m\u002Fs",{"id":363,"libraryId":5,"type":37,"typeLabel":38,"stem":364,"options":365,"answer":24,"analysis":34},880829,"每班运行不足( )的局部排风系统，当排风量可以补偿并不影响室内安全、卫生、环保要求时，可不设机械送风补偿所排出的风量。",[366,368,370,372],{"key":20,"text":367,"correct":32},"1h",{"key":24,"text":369,"correct":22},"2h",{"key":27,"text":371,"correct":32},"3h",{"key":30,"text":373,"correct":32},"4h",{"id":375,"libraryId":5,"type":37,"typeLabel":38,"stem":376,"options":377,"answer":24,"analysis":34},880830,"下列散热器对供暖热水酸碱度的要求，按从强碱性到强酸性的顺序排列是( )。",[378,380,382,384],{"key":20,"text":379,"correct":32},"钢制散热器，铝制散热器，铜制散热器",{"key":24,"text":381,"correct":22},"钢制散热器，铜制散热器，铝制散热器",{"key":27,"text":383,"correct":32},"铜制散热器，铝制散热器，钢制散热器",{"key":30,"text":385,"correct":32},"铜制散热器，钢制散热器，铝制散热器",{"id":387,"libraryId":5,"type":37,"typeLabel":38,"stem":388,"options":389,"answer":30,"analysis":34},880831,"固定床活性炭吸附装置的设计参数选取，下列错误的是( )。",[390,392,394,396],{"key":20,"text":391,"correct":32},"空塔速度一般取0.3～0.5m\u002Fs",{"key":24,"text":393,"correct":32},"吸附剂和气体接触时间取0.5～2.0s以上",{"key":27,"text":395,"correct":32},"吸附层压力损失应小于1kPa",{"key":30,"text":397,"correct":22},"采用热空气再生时，脱附再生温度宜为130～150℃",{"id":399,"libraryId":5,"type":37,"typeLabel":38,"stem":400,"options":401,"answer":30,"analysis":34},880832,"下列哪一项不是涡旋式压缩机的特点？( )",[402,404,406,408],{"key":20,"text":403,"correct":32},"没有进、排气阀，不存在余隙容积，内部泄漏可能性小，容积效率较高",{"key":24,"text":405,"correct":32},"具有内压缩的特点，可实现中间补气，故可以实现带经济器运行",{"key":27,"text":407,"correct":32},"采用轴向和径向的柔性密封，为压缩机吸气喷液冷却创造了条件",{"key":30,"text":409,"correct":22},"采用滑块进行无级调节",{"id":411,"libraryId":5,"type":37,"typeLabel":38,"stem":412,"options":413,"answer":24,"analysis":34},880833,"在焓湿图上，某室内空气状态点的等焓线与100%相对湿度线的交点的温度应为下列哪一项？( )",[414,416,418,420],{"key":20,"text":415,"correct":32},"该空气状态点的干球温度",{"key":24,"text":417,"correct":22},"该空气状态点的湿球温度",{"key":27,"text":419,"correct":32},"该空气状态点的露点温度",{"key":30,"text":421,"correct":32},"该空气状态点的机器露点温度",{"id":423,"libraryId":5,"type":37,"typeLabel":38,"stem":424,"options":425,"answer":30,"analysis":34},880834,"公共建筑围护结构建筑热工设计中，当窗户的传热系数满足节能标准的情况下，下列玻璃窗的选择，哪一项是错误的？",[426,428,430,432],{"key":20,"text":427,"correct":32},"同一窗墙比情况下，在夏热冬冷地区玻璃窗的遮阳系数限值应小于寒冷地区",{"key":24,"text":429,"correct":32},"在严寒地区，应选用遮阳系数大的玻璃",{"key":27,"text":431,"correct":32},"对寒冷地区窗墙比较小的情况，应选遮阳系数大的玻璃",{"key":30,"text":433,"correct":22},"对寒冷地区北向窗户，应选遮阳系数小的玻璃",{"id":435,"libraryId":5,"type":37,"typeLabel":38,"stem":436,"options":437,"answer":20,"analysis":34},880835,"高层民用建筑空调保温材料选择中，不正确的是( )。",[438,440,442,444],{"key":20,"text":439,"correct":22},"管道保温层外侧的保护层可以用难燃材料制作",{"key":24,"text":441,"correct":32},"穿越变形缝的风管的两侧2m以内应采用不燃材料保温",{"key":27,"text":443,"correct":32},"穿越防火墙的水管应采用不燃材料保温",{"key":30,"text":445,"correct":32},"炊事间灶具上方的空调风管应采用不燃保温材料保温",{"id":447,"libraryId":5,"type":37,"typeLabel":38,"stem":448,"options":449,"answer":24,"analysis":34},880836,"下列哪一项采暖建筑的热负荷计算方法是错误的？",[450,452,454,456],{"key":20,"text":451,"correct":32},"风力附加只对不避风的垂直外围护结构基本耗热量上做附加，但对其余也应在垂直投影面的基本耗热量上做附加",{"key":24,"text":453,"correct":22},"工业建筑渗透冷空气耗热量附加率是指占全部围护结构基本耗热量的",{"key":27,"text":455,"correct":32},"多层建筑的渗透冷空气耗热量，当无相关数据时，可按规定的换气次数计算",{"key":30,"text":457,"correct":32},"外门附加率只适用于短时间开启的、无热风幕的外门",{"id":459,"libraryId":5,"type":37,"typeLabel":38,"stem":460,"options":461,"answer":27,"analysis":34},880837,"为使吸收塔中的吸收液有效地净化有害气体，需要确定合适的液气比。影响液气比大小的主要因素中下列哪一项是错误的？( )",[462,464,466,468],{"key":20,"text":463,"correct":32},"气相进口浓度",{"key":24,"text":465,"correct":32},"相平衡常数",{"key":27,"text":467,"correct":22},"吸附剂动活性",{"key":30,"text":469,"correct":32},"液相进口浓度",{"id":471,"libraryId":5,"type":37,"typeLabel":38,"stem":34,"options":472,"answer":30,"analysis":34},880838,[473,475,477,479],{"key":20,"text":474,"correct":32},"0.2～0.3",{"key":24,"text":476,"correct":32},"0.3～0.4",{"key":27,"text":478,"correct":32},"0.4～0.5",{"key":30,"text":480,"correct":22},"0.5～0.6",{"id":482,"libraryId":5,"type":37,"typeLabel":38,"stem":483,"options":484,"answer":20,"analysis":34},880839,"一、两级除尘器，第一级效率为70%，第二级效率为80%，则总的除尘效率为( )。",[485,487,489,491],{"key":20,"text":486,"correct":22},"94%",{"key":24,"text":488,"correct":32},"90%",{"key":27,"text":490,"correct":32},"87%",{"key":30,"text":492,"correct":32},"95%",{"id":494,"libraryId":5,"type":37,"typeLabel":38,"stem":495,"options":496,"answer":30,"analysis":34},880840,"对于矩形风管，采用流量和( )，从图中查风管的单位长度摩擦阻力损失。",[497,499,501,503],{"key":20,"text":498,"correct":32},"管长",{"key":24,"text":500,"correct":32},"流速",{"key":27,"text":502,"correct":32},"流速当量直径",{"key":30,"text":504,"correct":22},"流量当量直径",{"id":506,"libraryId":5,"type":37,"typeLabel":38,"stem":507,"options":508,"answer":24,"analysis":34},880841,"PE-X管按照交联方式的不同，可分为PE-Xa，PE-Xb，PE-Xc，PE-Xd四种管材，四种管材的交联度不同，试问PE-Xc管(辐照交联聚乙烯)的交联度的要求应为下列哪一项？( )",[509,511,513,515],{"key":20,"text":510,"correct":32},"≥55%",{"key":24,"text":512,"correct":22},"≥60%",{"key":27,"text":514,"correct":32},"≥65%",{"key":30,"text":516,"correct":32},"≥70%",{"id":518,"libraryId":5,"type":37,"typeLabel":38,"stem":519,"options":520,"answer":20,"analysis":34},880842,"在吸收式制冷循环的热力计算中，多采用( )图。",[521,523,525,527],{"key":20,"text":522,"correct":22},"比焓-浓度",{"key":24,"text":524,"correct":32},"比焓-压力",{"key":27,"text":526,"correct":32},"温-熵",{"key":30,"text":528,"correct":32},"温度-浓度",{"id":530,"libraryId":5,"type":37,"typeLabel":38,"stem":531,"options":532,"answer":30,"analysis":34},880843,"高层民用建筑的中庭设机械排烟时，下列机械排烟量的计算正确的是( )。",[533,534,535,536],{"key":20,"text":34,"correct":32},{"key":24,"text":34,"correct":32},{"key":27,"text":34,"correct":32},{"key":30,"text":34,"correct":22},{"id":538,"libraryId":5,"type":37,"typeLabel":38,"stem":539,"options":540,"answer":30,"analysis":34},880844,"设计中，下列哪一项离心式制冷机机房的要求是不正确的？( )",[541,543,545,547],{"key":20,"text":542,"correct":32},"应考虑机房设备安装孔与运输设备通道的预留",{"key":24,"text":544,"correct":32},"应设置给水、排水设施",{"key":27,"text":546,"correct":32},"应有良好的室内通风设施",{"key":30,"text":548,"correct":22},"机房的隔墙应为防爆墙",{"id":550,"libraryId":5,"type":37,"typeLabel":38,"stem":551,"options":552,"answer":27,"analysis":34},880845,"热水用水定额表中规定的最高日用水定额，对应于什么水温？( )",[553,555,557,559],{"key":20,"text":554,"correct":32},"40℃",{"key":24,"text":556,"correct":32},"50℃",{"key":27,"text":558,"correct":22},"60℃",{"key":30,"text":560,"correct":32},"按不同用水器具分别确定",{"id":562,"libraryId":5,"type":37,"typeLabel":38,"stem":563,"options":564,"answer":20,"analysis":34},880846,"对于室内空气温度低于室外大气温度的房间，只有热压自然通风时，下列哪项是错误的？( )",[565,567,569,571],{"key":20,"text":566,"correct":22},"上部天窗排风，下部侧窗进风",{"key":24,"text":568,"correct":32},"上部天窗进风，下部侧窗排风",{"key":27,"text":570,"correct":32},"下部侧窗余压为正",{"key":30,"text":572,"correct":32},"中和界在上下窗孔之间",{"id":574,"libraryId":5,"type":37,"typeLabel":38,"stem":34,"options":575,"answer":24,"analysis":34},880847,[576,578,580,582],{"key":20,"text":577,"correct":32},"相同",{"key":24,"text":579,"correct":22},"人工焦炉煤气最大",{"key":27,"text":581,"correct":32},"天然气最大",{"key":30,"text":583,"correct":32},"液化石油气最大",{"id":585,"libraryId":5,"type":37,"typeLabel":38,"stem":586,"options":587,"answer":27,"analysis":34},880848,"《建规》不适用于下列哪一类别的建筑物？( )",[588,590,592,594],{"key":20,"text":589,"correct":32},"多层工业建筑",{"key":24,"text":591,"correct":32},"地下民用建筑",{"key":27,"text":593,"correct":22},"建筑高度超过24m的高层工业建筑",{"key":30,"text":595,"correct":32},"无窗厂房",{"id":597,"libraryId":5,"type":37,"typeLabel":38,"stem":598,"options":599,"answer":24,"analysis":34},880849,"一次节流完全中间冷却的双级压缩制冷循环减少了( )，耗功量少，制冷系数较单级大。",[600,602,604,606],{"key":20,"text":601,"correct":32},"节流损失",{"key":24,"text":603,"correct":22},"过热损失",{"key":27,"text":605,"correct":32},"压缩功",{"key":30,"text":607,"correct":32},"摩擦损失",{"id":609,"libraryId":5,"type":37,"typeLabel":38,"stem":610,"options":611,"answer":20,"analysis":34},880850,"下列关于冷凝器的选择，哪一组是正确的？①在冷却水质较差、水温较高和水量充足的地区，宜采用卧式壳管式冷凝器；②在冷却水质较好、水温较低的地区，宜采用组合式冷凝器；③在水质较差和夏季室外空气湿球温度较低的地区，可采用空冷式冷凝器；④在缺少水源和夏季室外空气湿球温度较低的地区，宜采用蒸发式冷凝器；⑤在缺水或无法供水的场合，可采用淋激式冷凝器。( )。",[612,614,616,618],{"key":20,"text":613,"correct":22},"①②③④",{"key":24,"text":615,"correct":32},"②④",{"key":27,"text":617,"correct":32},"①③⑤",{"key":30,"text":619,"correct":32},"①②③④⑤",[621,624,627,630,633,636],{"id":37,"name":622,"category":7,"favorite":623},"领导干部任职前廉政法规知识测试题",92,{"id":625,"name":626,"category":7,"favorite":37},595,"建筑结构与设备",{"id":628,"name":629,"category":7,"favorite":37},715,"招标采购专业知识与法律法规",{"id":631,"name":632,"category":7,"favorite":37},848,"市政方向-通用基础",{"id":634,"name":635,"category":7,"favorite":8},534,"BIM工程师",{"id":637,"name":635,"category":7,"favorite":8},535]