[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":623},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,2,50,2054,[13,33,47,60,73,86,98,110,122,136,149,161,173,185,197,209,221,233,246,258,270,282,294,306,319,331,343,355,367,379,390,402,414,426,438,449,461,473,485,496,508,520,528,540,552,564,575,587,599,611],{"id":14,"libraryId":5,"type":9,"typeLabel":15,"stem":16,"options":17,"answer":31,"analysis":32},879901,"多选题","重力循环热水供暖系统与机械循环热水供暖系统在下列哪些方面存在差异？( )",[18,22,25,28],{"key":19,"text":20,"correct":21},"A","膨胀水箱与系统的连接位置",true,{"key":23,"text":24,"correct":21},"B","系统循环动力",{"key":26,"text":27,"correct":21},"C","排气方式",{"key":29,"text":30,"correct":21},"D","水平供水干管的坡向和坡度","ABCD","",{"id":34,"libraryId":5,"type":9,"typeLabel":15,"stem":35,"options":36,"answer":46,"analysis":32},879902,"建筑热工设计分区中，夏热冬冷地区的主要分区指标是( )。",[37,40,42,44],{"key":19,"text":38,"correct":39},"日平均温度≥25℃的天数40～110d",false,{"key":23,"text":41,"correct":21},"最热月平均温度25～30℃",{"key":26,"text":43,"correct":39},"日平均温度≤5℃的天数0～90d",{"key":29,"text":45,"correct":21},"最冷月平均温度0～10℃","BD",{"id":48,"libraryId":5,"type":9,"typeLabel":15,"stem":49,"options":50,"answer":59,"analysis":32},879903,"夏热冬暖地区某高层办公楼仅设夏季空调，制冷机房位于地下室，送到空调末端的供回水温度为7℃\u002F12℃，关于标准层空调方式的选择，下列哪几项是错误的？( )",[51,53,55,57],{"key":19,"text":52,"correct":21},"风机盘管加新风空调系统，每层采用一套带喷水室的新风空气处理机组",{"key":23,"text":54,"correct":39},"变风量空调系统，每层采用一套带表冷器的空气处理机组",{"key":26,"text":56,"correct":21},"送风温度9℃的低温送风空调系统",{"key":29,"text":58,"correct":39},"风机盘管加新风空调系统，每层采用一套带表冷器的新风空气处理机组","AC",{"id":61,"libraryId":5,"type":9,"typeLabel":15,"stem":62,"options":63,"answer":72,"analysis":32},879904,"下列几个因素中，哪些与冷却产生的自然作用压力有关？( )",[64,66,68,70],{"key":19,"text":65,"correct":21},"并联环路之间的高差",{"key":23,"text":67,"correct":21},"供回水温差",{"key":26,"text":69,"correct":21},"系统形式",{"key":29,"text":71,"correct":39},"系统供回水的压差","ABC",{"id":74,"libraryId":5,"type":9,"typeLabel":15,"stem":75,"options":76,"answer":85,"analysis":32},879905,"下列说法错误的是( )。",[77,79,81,83],{"key":19,"text":78,"correct":21},"消声器宜布置在机房气流稳定的管段上",{"key":23,"text":80,"correct":21},"当消声器直接布置在机房内时，消声器、检查门及消声后的风管，应具有良好的消声能力",{"key":26,"text":82,"correct":39},"通风、空气调节和制冷机房，应根据邻近房间或建筑物的允许噪声标准，采取必要的隔音措施",{"key":29,"text":84,"correct":21},"管道穿过机房围护结构处，其孔洞四周的缝隙，应填充密实","ABD",{"id":87,"libraryId":5,"type":9,"typeLabel":15,"stem":88,"options":89,"answer":85,"analysis":32},879906,"确定高密度人群建筑的最小新风量时，主要考虑下列哪些因素？( )",[90,92,94,96],{"key":19,"text":91,"correct":21},"按办公建筑标准计算得到的新风冷负荷在空调冷负荷中所占比例较高",{"key":23,"text":93,"correct":21},"人流量变化大，高峰人流量持续时间短",{"key":26,"text":95,"correct":39},"室内空气的污染源主要是建筑物内的材料",{"key":29,"text":97,"correct":21},"大空间建筑内空气污染物浓度增加缓慢",{"id":99,"libraryId":5,"type":9,"typeLabel":15,"stem":100,"options":101,"answer":85,"analysis":32},879907,"下列关于卫生器具的水封，说法正确的是( )。",[102,104,106,108],{"key":19,"text":103,"correct":21},"卫生器具与生活污水管道或其他可能产生有害气体的排水管道直接连接时，必须在排水口以下设水封装置，其水封深度不得小于50mm",{"key":23,"text":105,"correct":21},"卫生器具与生活污水管道或其他可能产生有害气体的排水管道直接连接时，必须在排水口以下设水封装置，其水封深度不得小于30mm",{"key":26,"text":107,"correct":39},"坐便器等内置存水弯的卫生器具，不应在排水口以下再设水封装置",{"key":29,"text":109,"correct":21},"医院、教学、科研单位等有化学试剂排放的排水系统，不在同一房间内的卫生器具不得共用一个水封装置给水方式",{"id":111,"libraryId":5,"type":9,"typeLabel":15,"stem":112,"options":113,"answer":72,"analysis":32},879908,"洁净厂房中易燃易爆气体贮存、使用场所，采取措施正确的应是下列哪几项？( )",[114,116,118,120],{"key":19,"text":115,"correct":21},"设置可燃气体报警装置",{"key":23,"text":117,"correct":21},"应设自动和手动控制的事故排风系统",{"key":26,"text":119,"correct":21},"报警装置应与相应的事故排风机联锁",{"key":29,"text":121,"correct":39},"报警信号接至门卫值班室",{"id":123,"libraryId":5,"type":124,"typeLabel":125,"stem":126,"options":127,"answer":19,"analysis":32},879909,1,"单选题","下列空调系统设置集中监控系统的理由中，错误的是( )。",[128,130,132,134],{"key":19,"text":129,"correct":21},"工艺或使用条件对控制有一定要求",{"key":23,"text":131,"correct":39},"系统规模大、设备台数多",{"key":26,"text":133,"correct":39},"设备要求联锁保护",{"key":29,"text":135,"correct":39},"采用集中控制可合理利用能量，实现节能运行",{"id":137,"libraryId":5,"type":9,"typeLabel":15,"stem":138,"options":139,"answer":148,"analysis":32},879910,"下列哪些空调用水冷式冷水机组的冷却水温度表述是正确的？",[140,142,144,146],{"key":19,"text":141,"correct":39},"机组的冷却水进水温度越高越好",{"key":23,"text":143,"correct":39},"机组的冷却水进出口水温差越小越好",{"key":26,"text":145,"correct":21},"溴化锂吸收式冷水机组的冷却水进口温度最低不宜低于24℃",{"key":29,"text":147,"correct":21},"电动压缩式冷水机组的冷却水进口温度最低不宜低于15.5℃","CD",{"id":150,"libraryId":5,"type":124,"typeLabel":125,"stem":151,"options":152,"answer":23,"analysis":32},879911,"某公共建筑500㎡大堂采用地面辐射，计算热负荷为40kW，但其中200㎡的地面被固定式家具及其他摆设物所覆盖，辐射地面单位面积的有效散热量应为多少？",[153,155,157,159],{"key":19,"text":154,"correct":39},"180W\u002F㎡",{"key":23,"text":156,"correct":21},"133W\u002F㎡",{"key":26,"text":158,"correct":39},"120W\u002F㎡",{"key":29,"text":160,"correct":39},"102W\u002F㎡",{"id":162,"libraryId":5,"type":9,"typeLabel":15,"stem":163,"options":164,"answer":148,"analysis":32},879912,"采暖系统设置平衡阀、控制阀的说法，下列哪几项正确？",[165,167,169,171],{"key":19,"text":166,"correct":39},"自力式压差控制阀特别适合分户计量采暖系统",{"key":23,"text":168,"correct":39},"静态平衡阀应装设在区域采暖锅炉房集水器的干管上",{"key":26,"text":170,"correct":21},"采暖系统宜于回水管上安装平衡阀",{"key":29,"text":172,"correct":21},"管路上安装平衡阀后，不必再安装截止阀",{"id":174,"libraryId":5,"type":9,"typeLabel":15,"stem":175,"options":176,"answer":46,"analysis":32},879913,"以下风管材料选择，正确的是哪几项？",[177,179,181,183],{"key":19,"text":178,"correct":39},"除尘系统进入除尘器前的风管采用镀锌钢板",{"key":23,"text":180,"correct":21},"电镀车间的酸洗槽槽边吸风系统风管采用硬聚乙烯板",{"key":26,"text":182,"correct":39},"排除温度高于500℃气体的风管采用镀锌钢板",{"key":29,"text":184,"correct":21},"卫生间的排风管采用玻镁复合风管",{"id":186,"libraryId":5,"type":124,"typeLabel":125,"stem":187,"options":188,"answer":29,"analysis":32},879914,"设在高层建筑内的自动灭火系统的设备室，通风、空调机房，其隔墙的耐火极限不低于( )。",[189,191,193,195],{"key":19,"text":190,"correct":39},"O.50h",{"key":23,"text":192,"correct":39},"1.00h",{"key":26,"text":194,"correct":39},"1.50h",{"key":29,"text":196,"correct":21},"2.00h",{"id":198,"libraryId":5,"type":124,"typeLabel":125,"stem":199,"options":200,"answer":26,"analysis":32},879915,"关于活性炭特性，下列哪一项叙述是错误的？( )",[201,203,205,207],{"key":19,"text":202,"correct":39},"空气湿度大，吸附量减小",{"key":23,"text":204,"correct":39},"被吸附的物质浓度越高，吸附量也越高",{"key":26,"text":206,"correct":21},"吸附量随温度升高而上升",{"key":29,"text":208,"correct":39},"对环乙烷的吸附效果不如对苯的吸附效果",{"id":210,"libraryId":5,"type":124,"typeLabel":125,"stem":211,"options":212,"answer":23,"analysis":32},879916,"氨吸收式制冷机须设置精馏塔，而溴化锂吸收式制冷机则不需设置，这是因为氨与水的沸点温度接近，为了( )，所以要对溶液进行精馏。",[213,215,217,219],{"key":19,"text":214,"correct":39},"提高氨水溶液的浓度",{"key":23,"text":216,"correct":21},"提高制冷剂氨的纯度",{"key":26,"text":218,"correct":39},"降低制冷剂氨的纯度",{"key":29,"text":220,"correct":39},"获得纯冷剂水",{"id":222,"libraryId":5,"type":124,"typeLabel":125,"stem":223,"options":224,"answer":29,"analysis":32},879917,"从节能角度，水环热泵空调系统最适用于下列哪种情况？( )",[225,227,229,231],{"key":19,"text":226,"correct":39},"内区较大且常年有稳定余热的建筑",{"key":23,"text":228,"correct":39},"有低温余热可利用的情况",{"key":26,"text":230,"correct":39},"有太阳能辅助热源的情况",{"key":29,"text":232,"correct":21},"需要同时供冷和供热的情况",{"id":234,"libraryId":5,"type":9,"typeLabel":15,"stem":235,"options":236,"answer":245,"analysis":32},879918,"保冷(保温)材料应具备下列哪几项特性？",[237,239,241,243],{"key":19,"text":238,"correct":21},"导热系数小",{"key":23,"text":240,"correct":39},"材料中的气孔应为开孔",{"key":26,"text":242,"correct":39},"氧指数大于30",{"key":29,"text":244,"correct":21},"密度较小","AD",{"id":247,"libraryId":5,"type":9,"typeLabel":15,"stem":248,"options":249,"answer":85,"analysis":32},879919,"下列空调冷源设计中，不合理的是( )。",[250,252,254,256],{"key":19,"text":251,"correct":21},"空调冷负荷为500kW时，设置1台离心式冷水机组",{"key":23,"text":253,"correct":21},"要求机组制冷量从100%连续调节到10%的情况，选用2台离心式冷水机组",{"key":26,"text":255,"correct":39},"选择IPLV高的冷水机组",{"key":29,"text":257,"correct":21},"高档办公楼空调系统冷水机组设置3台，两用一备",{"id":259,"libraryId":5,"type":124,"typeLabel":125,"stem":260,"options":261,"answer":29,"analysis":32},879920,"某冷库底层冷间设计温度低于0℃，且地下为砂砾层，地下水位较低，该冷库底层地面( )。",[262,264,266,268],{"key":19,"text":263,"correct":39},"应作架空处理",{"key":23,"text":265,"correct":39},"埋设管道进行通风处理",{"key":26,"text":267,"correct":39},"埋设管道循环乙二醇溶液",{"key":29,"text":269,"correct":21},"只作隔汽防潮和保温处理",{"id":271,"libraryId":5,"type":9,"typeLabel":15,"stem":272,"options":273,"answer":72,"analysis":32},879921,"对于侧壁采用多个面积相同的孔口的均匀送风管道，实现风管均匀送风的基本条件正确的是( )。",[274,276,278,280],{"key":19,"text":275,"correct":21},"保持各测孔静压相等",{"key":23,"text":277,"correct":21},"保持各测孔流量系数相等",{"key":26,"text":279,"correct":21},"管内的静压与动压之比尽量加大",{"key":29,"text":281,"correct":39},"沿送风方向，孔口前后的风管截面平均风速降低",{"id":283,"libraryId":5,"type":124,"typeLabel":125,"stem":284,"options":285,"answer":19,"analysis":32},879922,"用于补偿消除余热、余湿全面排风耗热量时，机械送风的空气加热器应采用下列哪个室外计算温度？",[286,288,290,292],{"key":19,"text":287,"correct":21},"冬季通风",{"key":23,"text":289,"correct":39},"夏季通风",{"key":26,"text":291,"correct":39},"冬季采暖",{"key":29,"text":293,"correct":39},"冬季空调",{"id":295,"libraryId":5,"type":9,"typeLabel":15,"stem":296,"options":297,"answer":85,"analysis":32},879923,"关于氟利昂，下列说法正确的是( )。",[298,300,302,304],{"key":19,"text":299,"correct":21},"氟利昂是一类透明、无味、基本无毒又不易燃烧、爆炸、化学性能稳定的制冷剂",{"key":23,"text":301,"correct":21},"氟利昂能不同程度地溶解润滑油，不易在系统中形成油膜",{"key":26,"text":303,"correct":39},"氟利昂不易腐蚀铜管",{"key":29,"text":305,"correct":21},"氟利昂制冷系统在压缩机排出端应设分油器，以减少润滑油进入系统，安装系统时应考虑能顺利回油",{"id":307,"libraryId":5,"type":9,"typeLabel":15,"stem":308,"options":309,"answer":318,"analysis":32},879924,"有关蒸气压缩循环冷水(热泵)机组的IPLV值的说法，正确的是下列哪几项？",[310,312,314,316],{"key":19,"text":311,"correct":21},"IPLV值是制冷机组在部分负荷下的性能表现",{"key":23,"text":313,"correct":21},"同一地区、同类建筑采用IPLV数值高的机组，有利于节能",{"key":26,"text":315,"correct":39},"同一地区、同类建筑采用IPLV数值高的机组，不利于节能",{"key":29,"text":317,"correct":39},"IPLV值是制冷机组性能与系统负荷动态特性的匹配反映","AB",{"id":320,"libraryId":5,"type":124,"typeLabel":125,"stem":321,"options":322,"answer":26,"analysis":32},879925,"热水采暖系统中的重力作用压头与下列哪一项无关？",[323,325,327,329],{"key":19,"text":324,"correct":39},"锅炉安装高度",{"key":23,"text":326,"correct":39},"散热器安装高度",{"key":26,"text":328,"correct":21},"膨胀水箱安装高度",{"key":29,"text":330,"correct":39},"室内干管安装高度",{"id":332,"libraryId":5,"type":9,"typeLabel":15,"stem":333,"options":334,"answer":148,"analysis":32},879926,"不适合采用区域集中供冷的情况是( )。",[335,337,339,341],{"key":19,"text":336,"correct":39},"场区建筑物集中度较高时",{"key":23,"text":338,"correct":39},"各建筑物同时使用系数很小时",{"key":26,"text":340,"correct":21},"住宅小区",{"key":29,"text":342,"correct":21},"场区建筑物集中度较低时",{"id":344,"libraryId":5,"type":124,"typeLabel":125,"stem":345,"options":346,"answer":23,"analysis":32},879927,"人防地下室平时、战时分设通风系统时，战时通风系统风机按( )选用。",[347,349,351,353],{"key":19,"text":348,"correct":39},"战时滤毒式风量",{"key":23,"text":350,"correct":21},"战时清洁式风量",{"key":26,"text":352,"correct":39},"平时新风量",{"key":29,"text":354,"correct":39},"平时、战时最大新风量",{"id":356,"libraryId":5,"type":9,"typeLabel":15,"stem":357,"options":358,"answer":31,"analysis":32},879928,"高层民用建筑防烟楼梯间及消防电梯的独立前室或合用前室的作用，下述说法正确的是( )。",[359,361,363,365],{"key":19,"text":360,"correct":21},"可作为着火时的临时避难所",{"key":23,"text":362,"correct":21},"阻挡烟气直接进入防烟楼梯间或消防电梯井",{"key":26,"text":364,"correct":21},"作为消防队员达到着火层进行扑救工作的起点和安全区",{"key":29,"text":366,"correct":21},"降低建筑本身由热压差产生的烟囱效应",{"id":368,"libraryId":5,"type":9,"typeLabel":15,"stem":369,"options":370,"answer":148,"analysis":32},879929,"一类高层建筑中必须设置机械排烟设施的部位，应是下列哪几项？( )",[371,373,375,377],{"key":19,"text":372,"correct":39},"不具备自然排烟条件的仿烟楼梯间",{"key":23,"text":374,"correct":39},"设于4层的会议厅，其面积为300㎡、且可开启外窗为10㎡",{"key":26,"text":376,"correct":21},"净空高度为15m的中庭",{"key":29,"text":378,"correct":21},"面积为60㎡且设于地下二层的物业办公室",{"id":380,"libraryId":5,"type":124,"typeLabel":125,"stem":32,"options":381,"answer":26,"analysis":32},879930,[382,384,386,388],{"key":19,"text":383,"correct":39},"质量浓度",{"key":23,"text":385,"correct":39},"计数浓度",{"key":26,"text":387,"correct":21},"粒径颗粒浓度",{"key":29,"text":389,"correct":39},"粒径分布",{"id":391,"libraryId":5,"type":124,"typeLabel":125,"stem":392,"options":393,"answer":26,"analysis":32},879931,"下列对燃油锅炉房贮油罐总容量的阐述正确的是( )。",[394,396,398,400],{"key":19,"text":395,"correct":39},"火车或船舶运输，为15～20d的锅炉房最大计算耗油量",{"key":23,"text":397,"correct":39},"汽车油槽车运输，为3～4d的锅炉房最大计算耗油量",{"key":26,"text":399,"correct":21},"油管输送，为3～5d的锅炉房最大计算耗油量",{"key":29,"text":401,"correct":39},"油管输送，为4～6d的锅炉房最大计算耗油量",{"id":403,"libraryId":5,"type":124,"typeLabel":125,"stem":404,"options":405,"answer":26,"analysis":32},879932,"空调冷冻水系统的补水泵设计小时流量，宜为( )。",[406,408,410,412],{"key":19,"text":407,"correct":39},"冷冻水系统容量的1%",{"key":23,"text":409,"correct":39},"冷冻水系统循环水量的1%",{"key":26,"text":411,"correct":21},"冷冻水系统容量的5%～10%",{"key":29,"text":413,"correct":39},"冷冻水系统循环水量的2%～5%",{"id":415,"libraryId":5,"type":124,"typeLabel":125,"stem":416,"options":417,"answer":26,"analysis":32},879933,"高层建筑空调系统风管材料选择中，正确的是( )。",[418,420,422,424],{"key":19,"text":419,"correct":39},"风管不能采用难燃材料制作",{"key":23,"text":421,"correct":39},"接触腐蚀性气体的风管都可以采用难燃材料制作",{"key":26,"text":423,"correct":21},"柔性接头可以采用难燃材料制作",{"key":29,"text":425,"correct":39},"炊事间灶具上方的空调风管不能采用难燃材料制作",{"id":427,"libraryId":5,"type":124,"typeLabel":125,"stem":428,"options":429,"answer":23,"analysis":32},879934,"当墙体为砖砌结构时，围护结构最小热阻可比按式(2-1-2)计算所得值( )。",[430,432,434,436],{"key":19,"text":431,"correct":39},"小3%",{"key":23,"text":433,"correct":21},"小5%",{"key":26,"text":435,"correct":39},"大1%",{"key":29,"text":437,"correct":39},"大4%",{"id":439,"libraryId":5,"type":124,"typeLabel":125,"stem":440,"options":441,"answer":19,"analysis":32},879935,"以下制冷剂中，属于天然制冷剂的是( )。",[442,443,445,447],{"key":19,"text":32,"correct":21},{"key":23,"text":444,"correct":39},"R22",{"key":26,"text":446,"correct":39},"R134a",{"key":29,"text":448,"correct":39},"R12",{"id":450,"libraryId":5,"type":124,"typeLabel":125,"stem":451,"options":452,"answer":26,"analysis":32},879936,"建筑节能分部工程验收与单位工程竣工验收的顺序，正确的应是下列哪一项？",[453,455,457,459],{"key":19,"text":454,"correct":39},"建筑节能分部工程验收应在单位工程竣工验收合格后进行",{"key":23,"text":456,"correct":39},"单位工程竣工验收应与建筑节能分部工程验收同时进行",{"key":26,"text":458,"correct":21},"单位工程竣工验收应在建筑节能分部工程验收合格后进行",{"key":29,"text":460,"correct":39},"建筑节能分部工程验收与单位工程竣工验收的顺序由验收单位商定",{"id":462,"libraryId":5,"type":124,"typeLabel":125,"stem":463,"options":464,"answer":26,"analysis":32},879937,"某8层酒店建筑采用变制冷剂流量多联式空调(热泵)机组，在制冷工况条件下，对系统制冷能力修正时，不应采用的修正是下列哪一项？( )",[465,467,469,471],{"key":19,"text":466,"correct":39},"室内机额定制冷能力之和与室外机额定制冷能力的比值引起的修正",{"key":23,"text":468,"correct":39},"配管长度引起的修正",{"key":26,"text":470,"correct":21},"融霜引起的修正",{"key":29,"text":472,"correct":39},"室外机所处室外温度引起的修正",{"id":474,"libraryId":5,"type":124,"typeLabel":125,"stem":475,"options":476,"answer":29,"analysis":32},879938,"关于绿色公共建筑对水资源的有效利用，正确的是( )。",[477,479,481,483],{"key":19,"text":478,"correct":39},"必须设置雨水收集系统",{"key":23,"text":480,"correct":39},"必须设置中水处理系统",{"key":26,"text":482,"correct":39},"必须设置直饮水系统",{"key":29,"text":484,"correct":21},"统筹、综合利用各种水源",{"id":486,"libraryId":5,"type":124,"typeLabel":125,"stem":32,"options":487,"answer":29,"analysis":32},879939,[488,490,492,494],{"key":19,"text":489,"correct":39},"1.41",{"key":23,"text":491,"correct":39},"2.98",{"key":26,"text":493,"correct":39},"4",{"key":29,"text":495,"correct":21},"5.91",{"id":497,"libraryId":5,"type":124,"typeLabel":125,"stem":498,"options":499,"answer":29,"analysis":32},879940,"人防地下室滤毒通风时的新风量按( )。",[500,502,504,506],{"key":19,"text":501,"correct":39},"掩蔽人员计算所得新风量",{"key":23,"text":503,"correct":39},"保持室内超压时的漏风量",{"key":26,"text":505,"correct":39},"战时主要出入口最小防毒通道的设计换气次数所需风量",{"key":29,"text":507,"correct":21},"掩蔽人员计算所得新风量与保持室内超压时的漏风量加战时主要出入口最小防毒通道的设计换气次数所需风量之和的较大值",{"id":509,"libraryId":5,"type":124,"typeLabel":125,"stem":510,"options":511,"answer":29,"analysis":32},879941,"表面式空气热湿交换器可进行三种空气处理过程，下列选项正确的是( )。",[512,514,516,518],{"key":19,"text":513,"correct":39},"等湿加热、等湿冷却、绝热加湿",{"key":23,"text":515,"correct":39},"等湿冷却、绝热加湿、减湿冷却",{"key":26,"text":517,"correct":39},"减湿冷却、等湿加热、等湿冷却",{"key":29,"text":519,"correct":21},"减湿冷却、等温减湿、等湿冷却",{"id":521,"libraryId":5,"type":124,"typeLabel":125,"stem":522,"options":523,"answer":23,"analysis":32},879942,"按国家现行卫生标准，商场空调室内人员所需最小新风量，应为( )。",[524,525,526,527],{"key":19,"text":32,"correct":39},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":39},{"key":29,"text":32,"correct":39},{"id":529,"libraryId":5,"type":124,"typeLabel":125,"stem":530,"options":531,"answer":23,"analysis":32},879943,"设计燃气锅炉房，下列做法哪一项正确？",[532,534,536,538],{"key":19,"text":533,"correct":39},"当采用双管供气时，每条管道的通过能力按锅炉房总耗气量的65%计算，，",{"key":23,"text":535,"correct":21},"燃气配管系统适用的阀门选用明杆阀",{"key":26,"text":537,"correct":39},"燃气放散管出口高出屋脊1.5m",{"key":29,"text":539,"correct":39},"燃气管道穿越基础时，有条件时需设置套管",{"id":541,"libraryId":5,"type":124,"typeLabel":125,"stem":542,"options":543,"answer":29,"analysis":32},879944,"热力站内的换热设置，下列哪一项是错误的？( )",[544,546,548,550],{"key":19,"text":545,"correct":39},"换热器可以不设备用",{"key":23,"text":547,"correct":39},"采用2台或2台以上换热器，当其中1台停止运行时，其余换热器宜满足75%总计算负荷的需要",{"key":26,"text":549,"correct":39},"换热器为汽一水加热，当热负荷较小时，可采用汽-水混合加热装置",{"key":29,"text":551,"correct":21},"当加热介质为蒸汽时，不宜采用汽-水换热器和水-水换热器两级串联",{"id":553,"libraryId":5,"type":124,"typeLabel":125,"stem":554,"options":555,"answer":26,"analysis":32},879945,"相邻房间供暖设计温度不同时，哪种情况不需要计算通过隔墙和楼板的传热量？( )",[556,558,560,562],{"key":19,"text":557,"correct":39},"温差小于或等于5℃",{"key":23,"text":559,"correct":39},"温差大于或等于5℃、但传热量不大于高温失热房间供暖负荷的10%",{"key":26,"text":561,"correct":21},"温差小于5℃、且传热量不大于高温失热房间供暖负荷的10%",{"key":29,"text":563,"correct":39},"温差小于5℃、且传热量不大于低温得热房间供暖负荷的10%",{"id":565,"libraryId":5,"type":124,"typeLabel":125,"stem":32,"options":566,"answer":23,"analysis":32},879946,[567,569,571,573],{"key":19,"text":568,"correct":39},"安全阀或泄压阀",{"key":23,"text":570,"correct":21},"压力膨胀罐和安全阀",{"key":26,"text":572,"correct":39},"开式膨胀水箱或膨胀管",{"key":29,"text":574,"correct":39},"高位热水箱",{"id":576,"libraryId":5,"type":124,"typeLabel":125,"stem":577,"options":578,"answer":23,"analysis":32},879947,"排除有爆炸危险的气体、蒸汽和粉尘的局部排风系统，其风量应保证在正常运行和事故情况下，风管内这些物质浓度不大于下列哪一项数值？( )",[579,581,583,585],{"key":19,"text":580,"correct":39},"爆炸下限的90%",{"key":23,"text":582,"correct":21},"爆炸下限的50%",{"key":26,"text":584,"correct":39},"爆炸下限的60%",{"key":29,"text":586,"correct":39},"爆炸下限的70%",{"id":588,"libraryId":5,"type":124,"typeLabel":125,"stem":589,"options":590,"answer":19,"analysis":32},879948,"纯氨对( )几乎无腐蚀作用。",[591,593,595,597],{"key":19,"text":592,"correct":21},"钢铁",{"key":23,"text":594,"correct":39},"铝",{"key":26,"text":596,"correct":39},"铜",{"key":29,"text":598,"correct":39},"铜合金",{"id":600,"libraryId":5,"type":124,"typeLabel":125,"stem":601,"options":602,"answer":19,"analysis":32},879949,"水源热泵机组的性能系数COP的定义，下列哪一项是正确的？( )",[603,605,607,609],{"key":19,"text":604,"correct":21},"根据国家标准GB\u002FT19409-2003的方法实测制热量和实测制热水泵功率之比",{"key":23,"text":606,"correct":39},"根据国家标准GB\u002FT19409-2003的方法实测制热量和实测制冷水泵功率之比",{"key":26,"text":608,"correct":39},"产品铭牌的制热量与额定制热输入功率之比",{"key":29,"text":610,"correct":39},"产品铭牌的制冷量与额定制冷输入功率之比",{"id":612,"libraryId":5,"type":124,"typeLabel":125,"stem":613,"options":614,"answer":19,"analysis":32},879950,"燃油锅炉房输油泵的容量应不小于锅炉房小时最大计算耗油量的( )。",[615,617,619,621],{"key":19,"text":616,"correct":21},"110%",{"key":23,"text":618,"correct":39},"90%",{"key":26,"text":620,"correct":39},"105%",{"key":29,"text":622,"correct":39},"85%",[624,627,630,633,636,639],{"id":124,"name":625,"category":7,"favorite":626},"领导干部任职前廉政法规知识测试题",92,{"id":628,"name":629,"category":7,"favorite":124},595,"建筑结构与设备",{"id":631,"name":632,"category":7,"favorite":124},715,"招标采购专业知识与法律法规",{"id":634,"name":635,"category":7,"favorite":124},848,"市政方向-通用基础",{"id":637,"name":638,"category":7,"favorite":8},534,"BIM工程师",{"id":640,"name":638,"category":7,"favorite":8},535]