[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-19":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":627},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,19,50,2054,[13,35,48,61,73,86,99,111,123,135,147,159,171,183,196,208,221,234,247,259,266,278,290,302,314,326,338,352,364,376,388,400,411,423,435,447,459,471,483,495,507,519,531,543,555,567,579,591,603,615],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},880751,2,"多选题","建筑内电梯井设计时，下列哪几项要求是错误的？",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","电梯井内不宜敷设可燃气体管道",true,{"key":24,"text":25,"correct":26},"B","电梯井内严禁敷设甲、乙类液体管道",false,{"key":28,"text":29,"correct":26},"C","电梯井内严禁敷设甲、乙、丙类液体管道",{"key":31,"text":32,"correct":22},"D","电梯井内严禁敷设电线电缆","AD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},880752,"近年蒸汽压缩式制冷机组采用满液式蒸发器(蒸发管完全浸润在沸腾的制冷剂中)属于节能技术，对它的描述，下列哪几项是正确的?( )。",[39,41,43,45],{"key":20,"text":40,"correct":22},"满液式蒸发器的传热性能优于干式蒸发器",{"key":24,"text":42,"correct":22},"蒸发管外侧的换热系数得到提高",{"key":28,"text":44,"correct":26},"位于蒸发器底部的蒸发管的蒸发压力低于蒸发器上部的蒸发管的蒸发压力",{"key":31,"text":46,"correct":22},"位于蒸发器底部的蒸发管的蒸发压力高于蒸发器上部的蒸发管的蒸发压力","ABD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},880753,"下列哪些因素与排水立管的排水能力有关？( )",[52,54,56,58],{"key":20,"text":53,"correct":22},"通气管系的设置状况",{"key":24,"text":55,"correct":22},"管道材质",{"key":28,"text":57,"correct":22},"立管高度",{"key":31,"text":59,"correct":22},"管径","ABCD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":47,"analysis":34},880754,"在下述通风空调系统中，必须采用防爆型设备的是( )。",[65,67,69,71],{"key":20,"text":66,"correct":22},"直接布置在有甲、乙类物质场所的通风空调设备",{"key":24,"text":68,"correct":22},"排除有甲、乙类物质的通风设备",{"key":28,"text":70,"correct":26},"排除含有燃烧或爆炸危险的粉尘、纤维等丙类物质的通风设备",{"key":31,"text":72,"correct":22},"排除含有燃烧或爆炸危险的粉尘、纤维等丙类物质，其含尘浓度高于或等于其爆炸下限的25%时的设备",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":85,"analysis":34},880755,"对于冬、夏季均采用空调系统供热、供冷的建筑，采用冷却塔供冷，正确的说法应是下列哪几项？( )",[77,79,81,83],{"key":20,"text":78,"correct":22},"当楼层的内区在冬季有一定供冷需求时，可采用冷却塔供冷",{"key":24,"text":80,"correct":26},"采用冷却塔供冷时，末端的供冷能力应根据冷却塔所能提供的空调冷水参数来确定",{"key":28,"text":82,"correct":22},"当采用开式冷却塔时应设置换热器",{"key":31,"text":84,"correct":22},"当采用闭式冷却塔时可直接供水","ACD",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":98,"analysis":34},880756,"高层建筑空调的冷水系统形式的叙述中，正确的是( )。",[90,92,94,96],{"key":20,"text":91,"correct":22},"一般为闭式",{"key":24,"text":93,"correct":26},"一般为开式",{"key":28,"text":95,"correct":22},"可以为开式",{"key":31,"text":97,"correct":26},"不得采用开式","AC",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":110,"analysis":34},880757,"绿色居住建筑采用集中供暖或集中空调系统的住宅，必须采用( )。",[103,105,107,108],{"key":20,"text":104,"correct":22},"室温调节控制器",{"key":24,"text":106,"correct":22},"热量计量设施",{"key":28,"text":34,"correct":26},{"key":31,"text":109,"correct":26},"湿度调节控制器","AB",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":110,"analysis":34},880758,"燃油、燃气锅炉房布置在某多层商场建筑物内时，位置正确的是哪几项？",[115,117,119,121],{"key":20,"text":116,"correct":22},"首层靠外墙部位",{"key":24,"text":118,"correct":22},"地下一层外墙部位",{"key":28,"text":120,"correct":26},"地下二层",{"key":31,"text":122,"correct":26},"屋面层",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":33,"analysis":34},880759,"关于溴化锂吸收式制冷机组，下列哪几项说法是正确的？( )",[127,129,131,133],{"key":20,"text":128,"correct":22},"机组结构的密封性是最重要的技术条件",{"key":24,"text":130,"correct":26},"蒸发器、吸收器和发生器均采用喷淋式换热器",{"key":28,"text":132,"correct":26},"机组工作压力接近大气压力",{"key":31,"text":134,"correct":22},"必须设置抽气装置",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":98,"analysis":34},880760,"从绿色建筑评价标准角度看，下列哪些描述是正确的？( )",[139,141,143,145],{"key":20,"text":140,"correct":22},"酒店建筑房间隔墙可以用石膏板+100轻质陶粒混凝土构造",{"key":24,"text":142,"correct":26},"南方住宅可以设计单层Low-e防辐射玻璃窗",{"key":28,"text":144,"correct":22},"鼓励商场地下车库设计半下沉空间",{"key":31,"text":146,"correct":26},"夏热冬冷地区鼓励设计铺设PEX管的地板辐射制冷、供暖及独立新风的恒温恒湿住宅",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":33,"analysis":34},880761,"供暖负荷计算的高度附加率正确的是( )。",[151,153,155,157],{"key":20,"text":152,"correct":22},"房间高度大于4m时应计算",{"key":24,"text":154,"correct":26},"附加于房间的全部供暖负荷",{"key":28,"text":156,"correct":26},"附加于房间围护结构的传热负荷上",{"key":31,"text":158,"correct":22},"附加于房间围护结构的传热耗热量和其他附加耗热量上",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":47,"analysis":34},880762,"下列关于定压点设置，正确的说法是( )。",[163,165,167,169],{"key":20,"text":164,"correct":22},"两个承压相同水温不同的独立水系统可以采用同一个膨胀水箱定压",{"key":24,"text":166,"correct":22},"屋顶空气源热泵冷水机组的定压点应设置在水泵的入口",{"key":28,"text":168,"correct":26},"定压点不能设置在冷水机组的出口",{"key":31,"text":170,"correct":22},"膨胀水箱膨胀管的长短不影响系统水压分布",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":47,"analysis":34},880763,"关于空气处理过程的说法错误的是( )。",[175,177,179,181],{"key":20,"text":176,"correct":22},"空气处理过程在i-d图上一定是一条连接初始状态和终止状态的直线",{"key":24,"text":178,"correct":22},"由于水在低于0℃的环境下会结冰，因此湿球温度不可能低于0℃",{"key":28,"text":180,"correct":26},"溶液除湿器冬季可以实现加热加湿",{"key":31,"text":182,"correct":22},"由于喷雾加湿节省了汽化潜热，因此它是一种比蒸汽加湿节能的加湿方法",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":195,"analysis":34},880764,"进行某燃气锅炉房的通风设计，下列哪几项符合要求？",[187,189,191,193],{"key":20,"text":188,"correct":26},"通风换气次数3次／h，事故通风换气次数6次\u002Fh",{"key":24,"text":190,"correct":26},"通风换气次数6次\u002Fh，事故通风换气次数10次\u002Fh",{"key":28,"text":192,"correct":22},"通风换气次数6次\u002Fh，事故通风换气次数12次\u002Fh",{"key":31,"text":194,"correct":22},"通风换气次数8次\u002Fh，事故通风换气次数15次\u002Fh","CD",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":33,"analysis":34},880765,"下列哪些地方宜设置热空气幕？( )",[200,202,204,206],{"key":20,"text":201,"correct":22},"严寒地区公共建筑的外门",{"key":24,"text":203,"correct":26},"寒冷地区公共建筑的外门",{"key":28,"text":205,"correct":26},"严寒地区公共建筑不设门斗和前室的主要出入口",{"key":31,"text":207,"correct":22},"寒冷地区公共建筑不设门斗和前室的主要出入口",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":220,"analysis":34},880766,"人防地下室应具备通风换气条件的部位，应是( )。",[212,214,216,218],{"key":20,"text":213,"correct":26},"染毒通道",{"key":24,"text":215,"correct":22},"防毒通道",{"key":28,"text":217,"correct":22},"简易洗消间",{"key":31,"text":219,"correct":22},"人员掩蔽部","BCD",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":233,"analysis":34},880767,"下列属于填料塔优点的是( )。",[225,227,229,231],{"key":20,"text":226,"correct":22},"结构简单",{"key":24,"text":228,"correct":22},"管理方便",{"key":28,"text":230,"correct":22},"阻力较小",{"key":31,"text":232,"correct":26},"可净化含尘量大的气体","ABC",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":246,"analysis":34},880768,"下列有关除尘设备的设计选用原则和相关规定，错误的是( )。",[238,240,242,244],{"key":20,"text":239,"correct":26},"处理有爆炸危险粉尘的除尘器、排风机应与其他普通型的风机、除尘器分开设置",{"key":24,"text":241,"correct":22},"含有燃烧和爆炸危险粉尘的空气，在进入排风机前采用于式或湿式除尘器进行处理",{"key":28,"text":243,"correct":22},"净化有爆炸危险粉尘的干式除尘器，应布置在除尘系统的正压段",{"key":31,"text":245,"correct":26},"水硬性或疏水性粉尘不宜采用湿法除尘","BC",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":246,"analysis":34},880769,"下列有关通风设备和系统设计的要求，错误的是( )。",[251,253,255,257],{"key":20,"text":252,"correct":26},"对有易燃易爆物质房间进行排风的通风机应采用防爆型设备",{"key":24,"text":254,"correct":22},"对有易燃易爆物质房间进行送风的通风机不采用防爆型设备",{"key":28,"text":256,"correct":22},"通风机房不得与要求安静的房间贴临布置",{"key":31,"text":258,"correct":26},"排除有爆炸危险有害气体的风管应采取防静电接地措施",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":261,"answer":85,"analysis":34},880770,[262,263,264,265],{"key":20,"text":34,"correct":22},{"key":24,"text":34,"correct":26},{"key":28,"text":34,"correct":22},{"key":31,"text":34,"correct":22},{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":85,"analysis":34},880771,"改善重力沉降室的捕集效率的设计途径有( )。",[270,272,274,276],{"key":20,"text":271,"correct":22},"降低沉降室内气流速度",{"key":24,"text":273,"correct":26},"增大沉降室高度",{"key":28,"text":275,"correct":22},"增加重力沉降室的长度",{"key":31,"text":277,"correct":22},"增加重力沉降室的过流断面",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":220,"analysis":34},880772,"同一供暖房间如果把散热器面积增加一倍，则( )。",[282,284,286,288],{"key":20,"text":283,"correct":26},"散热量增加一倍",{"key":24,"text":285,"correct":22},"散热器热媒出口温度降低",{"key":28,"text":287,"correct":22},"散热器内热媒平均温度降低",{"key":31,"text":289,"correct":22},"散热器的传热系数减小",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":220,"analysis":34},880773,"在精度要求很高的恒温恒湿空调房间，为了更有效地控制空调房间内温湿度在规定范围内变化，不能采用( )。",[294,296,298,300],{"key":20,"text":295,"correct":26},"在空调风管的支管上加可调的电加热器",{"key":24,"text":297,"correct":22},"在空调箱加设可调的电加热器",{"key":28,"text":299,"correct":22},"在总风管上加加湿器",{"key":31,"text":301,"correct":22},"在空调箱内加设蒸汽加湿器",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":60,"analysis":34},880774,"下列对排水管管径说法，正确的是( )。",[306,308,310,312],{"key":20,"text":307,"correct":22},"公共浴室的排水管，管径应适当放大，一般不宜小于100mm",{"key":24,"text":309,"correct":22},"医院污物洗涤盆(池)和污水盆(池)的排水管径不得小于75mm",{"key":28,"text":311,"correct":22},"小便槽或连接3个以上小便器的排水支管管径不宜小于75mm",{"key":31,"text":313,"correct":22},"使用塑料螺旋管时，排水立管底部和排出管应比立管放大一号管径",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":195,"analysis":34},880775,"-类高层建筑中必须设置机械排烟设施的部位，应是下列哪些项？",[318,320,322,324],{"key":20,"text":319,"correct":26},"不具备自然排烟条件的防烟楼梯间",{"key":24,"text":321,"correct":26},"设于4层的会议厅，其面积为300㎡、且可开启外窗为10㎡",{"key":28,"text":323,"correct":22},"净空高度为15m的中庭",{"key":31,"text":325,"correct":22},"面积为60㎡且设于地下二层的物业办公室",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":220,"analysis":34},880776,"某办公楼采用风机盘管+新风的空调设计方案，冬夏兼用，在房间冬季空调热负荷中可以不考虑( )。",[330,332,334,336],{"key":20,"text":331,"correct":26},"外围护结构的传热负荷",{"key":24,"text":333,"correct":22},"门窗冷风渗透热负荷",{"key":28,"text":335,"correct":22},"室内人员的显热负荷",{"key":31,"text":337,"correct":22},"室内人员的潜热负荷",{"id":339,"libraryId":5,"type":340,"typeLabel":341,"stem":342,"options":343,"answer":24,"analysis":34},880777,1,"单选题","下列选项中不是供热管道保温的主要目的的是( )。",[344,346,348,350],{"key":20,"text":345,"correct":26},"减少热媒输送过程中的能量损失",{"key":24,"text":347,"correct":22},"保护供热管道防腐蚀",{"key":28,"text":349,"correct":26},"保证各热用户的热媒参数",{"key":31,"text":351,"correct":26},"保证操作人员安全，防止热力管道烫伤人",{"id":353,"libraryId":5,"type":340,"typeLabel":341,"stem":354,"options":355,"answer":20,"analysis":34},880778,"对同时散发热量和有害物质的车间，在夏季，应尽量采用( )；在冬季，当室外空气直接进入室内不致形成雾气和在围护结构内表面不致产生凝结水时，应考虑采用( )。",[356,358,360,362],{"key":20,"text":357,"correct":22},"自然通风；自然通风",{"key":24,"text":359,"correct":26},"自然通风和机械排风；自然通风",{"key":28,"text":361,"correct":26},"机械排风；机械通风",{"key":31,"text":363,"correct":26},"自然通风；机械通风",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":110,"analysis":34},880779,"热量表的设计安装，做法错误的是( )。",[368,370,372,374],{"key":20,"text":369,"correct":22},"热量表根据管道直径直接选用",{"key":24,"text":371,"correct":22},"热量表的流量传感器宜安装在供水管上",{"key":28,"text":373,"correct":26},"热量表和直管段之间不应设置变径",{"key":31,"text":375,"correct":26},"热量表调试时应设置存储参数和周期",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":246,"analysis":34},880780,"就锅炉房设置备用锅炉，下列哪几项做法是错误的？( )",[380,382,384,386],{"key":20,"text":381,"correct":26},"住宅小区供暖锅炉房可不设备用锅炉",{"key":24,"text":383,"correct":22},"机械加工车间供暖锅炉房应设备用锅炉",{"key":28,"text":385,"correct":22},"以生产负荷为主的锅炉房，当非供暖期至少能停用1台锅炉进行检修时，应设备用锅炉",{"key":31,"text":387,"correct":26},"药厂发酵车间供发酵使用的应设备用锅炉",{"id":389,"libraryId":5,"type":340,"typeLabel":341,"stem":390,"options":391,"answer":20,"analysis":34},880781,"在连接( )的大便器的塑料排水横管上宜设置清扫口。",[392,394,396,398],{"key":20,"text":393,"correct":22},"2个及2个以上",{"key":24,"text":395,"correct":26},"3个及3个以上",{"key":28,"text":397,"correct":26},"4个及4个以上",{"key":31,"text":399,"correct":26},"以上皆不是",{"id":401,"libraryId":5,"type":340,"typeLabel":341,"stem":34,"options":402,"answer":24,"analysis":34},880782,[403,405,407,409],{"key":20,"text":404,"correct":26},"系统的总阻抗减小，总流量增加",{"key":24,"text":406,"correct":22},"各用户的流量均增加",{"key":28,"text":408,"correct":26},"用户2的流量增加，用户1，3的流量减小",{"key":31,"text":410,"correct":26},"用户2的室温升高，用户1，3的室温降低",{"id":412,"libraryId":5,"type":340,"typeLabel":341,"stem":413,"options":414,"answer":20,"analysis":34},880783,"下列哪种设计方法对提高热网的水力稳定性有利？( )",[415,417,419,421],{"key":20,"text":416,"correct":22},"室外管网取较小的比摩阻，用户管网取较大的比摩阻",{"key":24,"text":418,"correct":26},"室外管网取较大的比摩阻，用户管网取较小的比摩阻",{"key":28,"text":420,"correct":26},"室外管网和用户管网均取较大的比摩阻",{"key":31,"text":422,"correct":26},"室外管网和用户管网均取较小的比摩阻",{"id":424,"libraryId":5,"type":340,"typeLabel":341,"stem":425,"options":426,"answer":20,"analysis":34},880784,"风机盘管的额定性能参数是什么状况下的？( )",[427,429,431,433],{"key":20,"text":428,"correct":22},"高速挡",{"key":24,"text":430,"correct":26},"中速挡",{"key":28,"text":432,"correct":26},"低速挡",{"key":31,"text":434,"correct":26},"其他特定状态",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":33,"analysis":34},880785,"有关空调系统风口的做法，下列哪几项是不合理的？",[439,441,443,445],{"key":20,"text":440,"correct":22},"某大型展厅60m跨度，设置射程为30m的喷口两侧对吹",{"key":24,"text":442,"correct":26},"某会议室净高3.3m，采用旋流送风口下送风",{"key":28,"text":444,"correct":26},"某剧场观众厅采用座椅送风口",{"key":31,"text":446,"correct":22},"某净高4m的车间(20℃)采用孔板送风",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":195,"analysis":34},880786,"关于冰蓄冷十低温送风系统的优点，说法正确的应是下列哪几项？",[451,453,455,457],{"key":20,"text":452,"correct":26},"比采用常规电制冷系统十常规全空气空调系统初投资要节约",{"key":24,"text":454,"correct":26},"比采用常规电制冷系统十常规全空气空调系统运行能耗节约",{"key":28,"text":456,"correct":22},"适用于电力增容受到限制和风管安装空间受到限制的工程",{"key":31,"text":458,"correct":22},"比采用常规全空气空调系统，空调风系统的风机和风管尺寸减小",{"id":460,"libraryId":5,"type":340,"typeLabel":341,"stem":461,"options":462,"answer":28,"analysis":34},880787,"在北京市某办公楼空调冷水系统循环水泵扬程选择计算中，不正确的是( )。",[463,465,467,469],{"key":20,"text":464,"correct":26},"循环水泵扬程取10%的安全系数",{"key":24,"text":466,"correct":26},"按夏季工况进行系统阻力计算",{"key":28,"text":468,"correct":22},"应考虑阀门调节状态对阻力的影响",{"key":31,"text":470,"correct":26},"按最不利环路进行阻力计算",{"id":472,"libraryId":5,"type":340,"typeLabel":341,"stem":473,"options":474,"answer":28,"analysis":34},880788,"设计某洁净室，经计算，保证空气洁净度所需风量为5万m3\u002Fh，保持室内正压为1万m3\u002Fh，供给工作人员的新风量为1.5万m3\u002Fh，室内排风量为2万m3\u002Fh，试问需要想室内补充的新风量为下列哪一项？",[475,477,479,481],{"key":20,"text":476,"correct":26},"2万m3\u002Fh",{"key":24,"text":478,"correct":26},"2.5万m3\u002Fh",{"key":28,"text":480,"correct":22},"3万m3\u002Fh",{"key":31,"text":482,"correct":26},"5万m3\u002Fh",{"id":484,"libraryId":5,"type":340,"typeLabel":341,"stem":485,"options":486,"answer":20,"analysis":34},880789,"关于空气源热泵的说法，下列哪一项是错误的？",[487,489,491,493],{"key":20,"text":488,"correct":22},"空气源热泵可在-20℃的外界环境下制取地板辐射采暖所需的30℃的热水",{"key":24,"text":490,"correct":26},"制取同样参数和数量的热水，空气源热泵消耗的电能多于水源热泵消耗的电能",{"key":28,"text":492,"correct":26},"空气源热泵的室外换热器有沙尘覆盖时会降低制热效率",{"key":31,"text":494,"correct":26},"空气源热泵工作的室外温度越低，结霜不一定越严重",{"id":496,"libraryId":5,"type":340,"typeLabel":341,"stem":497,"options":498,"answer":31,"analysis":34},880790,"为保证建筑的自然通风效果，建筑的主要进风面一般应与夏季主导风向呈( )角，不宜( )角。",[499,501,503,505],{"key":20,"text":500,"correct":26},"45°，大于60°～90°",{"key":24,"text":502,"correct":26},"45°，小于60°～90°",{"key":28,"text":504,"correct":26},"60°～90°，大于45°",{"key":31,"text":506,"correct":22},"60°～90°，小于45°",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":98,"analysis":34},880791,"关于制冷剂R410 A，下列哪几种说法是正确的？( )",[511,513,515,517],{"key":20,"text":512,"correct":22},"与R22相比，需要提高设备耐压强度",{"key":24,"text":514,"correct":26},"与R22相比，可以减小设备耐压强度",{"key":28,"text":516,"correct":22},"与R22相比，制冷效率可以提高",{"key":31,"text":518,"correct":26},"与R22相比，制冷效率降低",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":220,"analysis":34},880792,"洁净室的排风系统设计中，为防止室外空气倒灌措施可采用( )。",[523,525,527,529],{"key":20,"text":524,"correct":26},"调节阀",{"key":24,"text":526,"correct":22},"止回阀",{"key":28,"text":528,"correct":22},"密闭阀",{"key":31,"text":530,"correct":22},"中效过滤器",{"id":532,"libraryId":5,"type":340,"typeLabel":341,"stem":533,"options":534,"answer":31,"analysis":34},880793,"燃气锅炉房内燃气管道的放散管出口应高出屋脊( )。",[535,537,539,541],{"key":20,"text":536,"correct":26},"5m以上",{"key":24,"text":538,"correct":26},"4m以上",{"key":28,"text":540,"correct":26},"3m以上",{"key":31,"text":542,"correct":22},"2m以上",{"id":544,"libraryId":5,"type":340,"typeLabel":341,"stem":545,"options":546,"answer":20,"analysis":34},880794,"下列哪种元件属于小型氟利昂制冷系统所必需的？( )",[547,549,551,553],{"key":20,"text":548,"correct":22},"干燥过滤器",{"key":24,"text":550,"correct":26},"气液分离器",{"key":28,"text":552,"correct":26},"溶液泵",{"key":31,"text":554,"correct":26},"油压表",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":195,"analysis":34},880795,"冰蓄冷的制冷机组选型，不能采用的机组是下列哪几项？",[559,561,563,565],{"key":20,"text":560,"correct":26},"螺杆式制冷压缩机组",{"key":24,"text":562,"correct":26},"离心式制冷压缩机组",{"key":28,"text":564,"correct":22},"单效溴化锂吸收式制冷机组",{"key":31,"text":566,"correct":22},"双效溴化锂吸收式制冷机组",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":85,"analysis":34},880796,"围护结构的内表面温度应( )。",[571,573,575,577],{"key":20,"text":572,"correct":22},"能满足使用要求和卫生要求",{"key":24,"text":574,"correct":26},"内表面不结露",{"key":28,"text":576,"correct":22},"室内空气温度与围护结构内表面温度的差值不能过大",{"key":31,"text":578,"correct":22},"内表面不结露(相对湿度过大的房间除外)",{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":98,"analysis":34},880797,"《地源热泵系统工程技术规范(2009年版)》GB50036进行了重要修订的是下列哪几项？",[583,585,587,589],{"key":20,"text":584,"correct":22},"统一规范岩土热响应试验方法",{"key":24,"text":586,"correct":26},"明确提出对于利用地埋管地源热源系统的建筑，当应用建筑面积大于式等于3000㎡时，应进行热响应试验",{"key":28,"text":588,"correct":22},"明确提出岩土热响应试验应符合附录C的规定",{"key":31,"text":590,"correct":26},"提出地埋管换热器计算时，环路集管不应包括在地埋管换热器长度内",{"id":592,"libraryId":5,"type":340,"typeLabel":341,"stem":593,"options":594,"answer":24,"analysis":34},880798,"燃气冷热电三联供系统中，哪种发电装置获得的高温余热量最大？( )",[595,597,599,601],{"key":20,"text":596,"correct":26},"内燃机型发电机组",{"key":24,"text":598,"correct":22},"燃气轮机型发电机组",{"key":28,"text":600,"correct":26},"微燃气轮机型发电机组",{"key":31,"text":602,"correct":26},"都差不多",{"id":604,"libraryId":5,"type":340,"typeLabel":341,"stem":605,"options":606,"answer":31,"analysis":34},880799,"计算空调系统冷负荷时，除了房间空调冷负荷以外，还需考虑附加冷负荷，下列附加冷负荷选项哪一项是不对的？( )",[607,609,611,613],{"key":20,"text":608,"correct":26},"新风冷负荷",{"key":24,"text":610,"correct":26},"空调风管温升引起的冷负荷",{"key":28,"text":612,"correct":26},"风机、水泵温升引起的冷负荷",{"key":31,"text":614,"correct":22},"室内照明发热引起的冷负荷",{"id":616,"libraryId":5,"type":15,"typeLabel":16,"stem":617,"options":618,"answer":233,"analysis":34},880800,"计算自动喷水灭火系统的设计流量时，应注意的是( )。",[619,621,623,625],{"key":20,"text":620,"correct":22},"保证任意作用面积内的平均喷水强度不低于规范中的规定值",{"key":24,"text":622,"correct":22},"设置货架内喷头的仓库，顶板下喷头与货架内喷头应分别计算设计流量，并按其设计流量之和确定系统的设计流量",{"key":28,"text":624,"correct":22},"一层以上的机械式立体汽车库、复式汽车库可暂按每增加一层增加2个开放喷头数确定系统设计流量",{"key":31,"text":626,"correct":26},"最不利点处作用面积内任意4只喷头围合范围内的平均喷水强度，轻、中危险级不应低于规定值的80%",[628,631,634,637,640,643],{"id":340,"name":629,"category":7,"favorite":630},"领导干部任职前廉政法规知识测试题",92,{"id":632,"name":633,"category":7,"favorite":340},595,"建筑结构与设备",{"id":635,"name":636,"category":7,"favorite":340},715,"招标采购专业知识与法律法规",{"id":638,"name":639,"category":7,"favorite":340},848,"市政方向-通用基础",{"id":641,"name":642,"category":7,"favorite":8},534,"BIM工程师",{"id":644,"name":642,"category":7,"favorite":8},535]