[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-18":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":632},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,18,50,2054,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,193,206,218,229,242,255,268,281,294,306,317,329,342,354,366,378,390,402,414,426,438,450,462,474,487,499,511,523,536,548,560,572,584,596,608,620],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},880701,1,"单选题","冷藏库建筑墙体围护结构的组成，由室外到库内的排列顺序，下列哪一项是正确的？( )",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","墙体，隔热层，隔汽层，面层",false,{"key":24,"text":25,"correct":22},"B","墙体，隔热层，防潮层，面层",{"key":27,"text":28,"correct":29},"C","墙体，隔汽层，隔热层，面层",true,{"key":31,"text":32,"correct":22},"D","面层，隔热层，墙体，隔汽层，面层","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},880702,"对于散发热、湿或有害物的车间(或房间)在设计时应首先考虑采用( )的方式。",[38,40,42,44],{"key":20,"text":39,"correct":22},"全面通风",{"key":24,"text":41,"correct":29},"局部通风",{"key":27,"text":43,"correct":22},"以全面通风为主",{"key":31,"text":45,"correct":22},"以局部通风为主",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},880703,"选择低温送风口时，送风口的表面温度应( )。",[50,52,54,56],{"key":20,"text":51,"correct":22},"等于室内空气露点温度即可",{"key":24,"text":53,"correct":29},"高于室内空气露点温度1～2℃",{"key":27,"text":55,"correct":22},"高于室内空气露点温度0.5～1℃",{"key":31,"text":57,"correct":22},"低于室内温度即可",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},880704,"某除尘系统设计排风量L=30000m3\u002Fh，空气温度t=180℃，入口含尘浓度yl=2.0g\u002Fm3，除尘效率η=95%。试问下列哪一项是错误的？",[62,64,66,68],{"key":20,"text":63,"correct":29},"排风浓度为10mg\u002Fm3(标准状态)",{"key":24,"text":65,"correct":22},"排尘量为3kg\u002Fh",{"key":27,"text":67,"correct":22},"设计工况空气密度约0.78kg\u002Fm3",{"key":31,"text":69,"correct":22},"标准工况下排风量约为18100m3\u002Fh(标准状态)",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},880705,"某地区室外冬季空调计算温度为-12℃，在该气温下，一台空气源热泵冷热水机组的制热量为100kW，输入功率为60kW，在60kW。工况下，制冷量为150kW，输入功率为60kW。下列说法中正确的是( )。",[74,76,78,80],{"key":20,"text":75,"correct":22},"该机组适合于该地区中、小型公共建筑的冬、夏季空调",{"key":24,"text":77,"correct":22},"该机组适合于该地区中、小型公共建筑的冬季空调",{"key":27,"text":79,"correct":22},"该机组适合于该地区中、小型公共建筑的夏季空调",{"key":31,"text":81,"correct":29},"该机组不适合于该地区公共建筑的冬、夏季空调",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},880706,"全年运行的空调制冷系统，对冷水机组冷却水最低进水温度进行控制(限制)的原因是什么?( )。",[86,88,90,92],{"key":20,"text":87,"correct":29},"该水温低于最低限值时，会导致冷水机组的制冷系统运行不稳定",{"key":24,"text":89,"correct":22},"该水温低于最低限值时，会导致冷水机组的COP降低",{"key":27,"text":91,"correct":22},"该水温低于最低限值时，会导致冷水机组的制冷量下降",{"key":31,"text":93,"correct":22},"该水温低于最低限值时，会导致冷却塔无法工作",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},880707,"除尘系统风管设计的做法，下列哪一项是错误的？",[98,100,102,104],{"key":20,"text":99,"correct":22},"风管采用垂直敷设",{"key":24,"text":101,"correct":29},"风管采用倾斜敷设时，与水平面的夹角应为30°",{"key":27,"text":103,"correct":22},"三通的夹角采用30°",{"key":31,"text":105,"correct":22},"支管从主管的侧面连接",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},880708,"热力站内热交换器的设置，下列哪一项是错误的？",[110,112,114,116],{"key":20,"text":111,"correct":22},"当一次热源稳定性差时，换热器的换热面积应乘以1.1～1.2的系数",{"key":24,"text":113,"correct":29},"采用两台或两台以上换热器时，当其中一台停止运行时，其余换热器应满足70%系统负荷的需求",{"key":27,"text":115,"correct":22},"换热器为汽一水加热时，当热负荷较小，可采用汽一水混合加热装置",{"key":31,"text":117,"correct":22},"采用汽水换热器和热水换热器两级串联时，水一水换热器排出的凝结水温度不宜超过80℃",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},880709,"下列关于保障防空地下室战时功能的通风，说法正确的是哪项?( )。",[122,124,126,128],{"key":20,"text":123,"correct":22},"包括清洁通风、滤毒通风、超压排风三种",{"key":24,"text":125,"correct":22},"包括清洁通风、隔绝通风、超压排风三种",{"key":27,"text":127,"correct":22},"包括清洁通风、滤毒通风、平时排风三种",{"key":31,"text":129,"correct":29},"包括清洁通风、滤毒通风、隔绝排风三种",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":27,"analysis":33},880710,"集中热水室内供暖系统计算，采用变温降法或等温降法的下列概念中，哪一项是错误的？( )",[134,136,138,140],{"key":20,"text":135,"correct":22},"变温降法的计算结果，更符合实际运行过程",{"key":24,"text":137,"correct":22},"如果并联环路之间的水力平衡度符合规范要求，采用等温降法的计算结果，可以比较接近实际运行过程",{"key":27,"text":139,"correct":29},"采用变温降法或等温降法计算，同一房间的散热器数量都是相同的",{"key":31,"text":141,"correct":22},"采用变温降法或等温降法计算，都应该保证满足计算环路所需要的流量范围",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":27,"analysis":33},880711,"某住宅小区中的一栋3层会馆采用重力循环热水供暖系统，每层的散热器均并联在供回水立管间，热水直接被分配到各层散热器，冷却后的水由回水支、立管及干管回流至锅炉。该系统形式属于( )。",[146,148,150,152],{"key":20,"text":147,"correct":22},"单管下供上回跨越式系统",{"key":24,"text":149,"correct":22},"单管上供下回系统",{"key":27,"text":151,"correct":29},"双管上供下回系统",{"key":31,"text":153,"correct":22},"水平跨越式系统",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":20,"analysis":33},880712,"室内消火栓在布置时，一般不能采用双出口的消火栓代替两支水枪，但在( )普通住宅中，可以只设一条双出口的消火栓。",[158,160,162,164],{"key":20,"text":159,"correct":29},"18层及18层以下，每层不超过8户，建筑面积不超过650㎡",{"key":24,"text":161,"correct":22},"18层及18层以下，每层不超过10户，建筑面积不超过850㎡",{"key":27,"text":163,"correct":22},"18层及18层以下，每层不超过6户，建筑面积不超过500㎡",{"key":31,"text":165,"correct":22},"16层及16层以下，每层不超过6户，建筑面积不超过500㎡",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},880713,"关于风帽的选用说法，下列哪一项是错误的？",[170,172,174,176],{"key":20,"text":171,"correct":22},"筒形风帽适用自然通风系统",{"key":24,"text":173,"correct":29},"避风风帽适用在室外空气正压区内的自然排风口上安装",{"key":27,"text":175,"correct":22},"锥形风帽适用于除尘系统",{"key":31,"text":177,"correct":22},"圆伞形风帽适用于一般的机械通风系统",{"id":179,"libraryId":5,"type":180,"typeLabel":181,"stem":182,"options":183,"answer":192,"analysis":33},880714,2,"多选题","安装制冷系统制冷剂管路时，管路应保持一定坡度。下列哪几项说法是正确的？( )",[184,186,188,190],{"key":20,"text":185,"correct":29},"氨压缩机至油分离器的排气管，应坡向油分离器",{"key":24,"text":187,"correct":29},"氟利昂压缩机吸气管应坡向压缩机",{"key":27,"text":189,"correct":22},"液体分配站至蒸发器(排管)的供液管，应坡向蒸发器(排管)",{"key":31,"text":191,"correct":22},"氟利昂蒸发器(排管)至回气管，应坡向蒸发器(排管)","AB",{"id":194,"libraryId":5,"type":180,"typeLabel":181,"stem":195,"options":196,"answer":205,"analysis":33},880715,"关于通风机的能效和节能评价，下列哪几项表述是错误的？( )",[197,199,201,203],{"key":20,"text":198,"correct":22},"能效限定值是在标准规定测试条件下允许通风机的效率最低保证值",{"key":24,"text":200,"correct":22},"能效等级是在标准规定测试条件下节能型通风机效率应达到的最低保证值",{"key":27,"text":202,"correct":29},"能效等级共分为3级，其中3级能效最高",{"key":31,"text":204,"correct":29},"对使用进气箱的离心风机，其各级能效规定的效率可下降3%","CD",{"id":207,"libraryId":5,"type":180,"typeLabel":181,"stem":208,"options":209,"answer":205,"analysis":33},880716,"热泵机组宜采用封闭式压缩机的主要原因是( )。",[210,212,214,216],{"key":20,"text":211,"correct":22},"蒸发温度变化范围大，冷凝温度高",{"key":24,"text":213,"correct":22},"因为封闭式压缩机都设气液分离器",{"key":27,"text":215,"correct":29},"由吸气冷却带走内置电动机的热量可以转移为热泵的制热量",{"key":31,"text":217,"correct":29},"有利于避免湿蒸气进入气缸",{"id":219,"libraryId":5,"type":180,"typeLabel":181,"stem":33,"options":220,"answer":228,"analysis":33},880717,[221,223,225,226],{"key":20,"text":222,"correct":29},"能满足使用要求和卫生要求",{"key":24,"text":224,"correct":22},"内表面不结露",{"key":27,"text":33,"correct":29},{"key":31,"text":227,"correct":29},"内表面不结露(相对湿度过大的房间除外)","ACD",{"id":230,"libraryId":5,"type":180,"typeLabel":181,"stem":231,"options":232,"answer":241,"analysis":33},880718,"下列关于空调系统调试的说法中，正确的是( )。",[233,235,237,239],{"key":20,"text":234,"correct":22},"由建设单位总负责，施工单位负责操作、设计单位负责技术指导、监理单位负责监督检查",{"key":24,"text":236,"correct":29},"空调系统带冷(热)源的正常联合试运行不应少于8h",{"key":27,"text":238,"correct":29},"风机和水泵连续运转不少于2h",{"key":31,"text":240,"correct":29},"冷水机组连续运转不少于8h","BCD",{"id":243,"libraryId":5,"type":180,"typeLabel":181,"stem":244,"options":245,"answer":254,"analysis":33},880719,"洁净空调系统除风管应采用不燃材料外，允许采用难燃材料的应是下列哪几项？( )",[246,248,250,252],{"key":20,"text":247,"correct":29},"保温材料",{"key":24,"text":249,"correct":29},"消声材料",{"key":27,"text":251,"correct":29},"粘结剂",{"key":31,"text":253,"correct":29},"各类附件","ABCD",{"id":256,"libraryId":5,"type":180,"typeLabel":181,"stem":257,"options":258,"answer":267,"analysis":33},880720,"下列措施中，可以降低声源噪声的是( )。",[259,261,263,265],{"key":20,"text":260,"correct":29},"尽量选用高效率、低噪声通风机和水泵",{"key":24,"text":262,"correct":22},"设计较大的系统风量和阻力",{"key":27,"text":264,"correct":22},"通风机进出口处的管道宜急剧转弯",{"key":31,"text":266,"correct":29},"弯头和三通支管等处宜装设导流叶片","AD",{"id":269,"libraryId":5,"type":180,"typeLabel":181,"stem":270,"options":271,"answer":280,"analysis":33},880721,"根据《公建节能》，下列哪几项是正确的？( )",[272,274,276,278],{"key":20,"text":273,"correct":29},"当窗墙面积比小于0.40时，玻璃(或其他透明材料)的可见光透射比不应小于0.40",{"key":24,"text":275,"correct":29},"屋顶透明部分的面积不应大于屋顶总面积的20%",{"key":27,"text":277,"correct":29},"夏热冬暖地区屋面传热系数应≤0.90W\u002F(㎡·K)",{"key":31,"text":279,"correct":22},"夏热冬冷地区建筑的体形系数应小于或等于0.40","ABC",{"id":282,"libraryId":5,"type":180,"typeLabel":181,"stem":283,"options":284,"answer":293,"analysis":33},880722,"设备布置间距的要求有( )。",[285,287,289,291],{"key":20,"text":286,"correct":29},"主要通道和操作走道宽度不小于1.5m",{"key":24,"text":288,"correct":29},"非主要通道不小于0.8m",{"key":27,"text":290,"correct":22},"压缩机凸出部分与配电盘之间不小于1.2m",{"key":31,"text":292,"correct":29},"压缩机侧面凸出部分不小于1.0m","ABD",{"id":295,"libraryId":5,"type":180,"typeLabel":181,"stem":296,"options":297,"answer":254,"analysis":33},880723,"冷库外围护结构隔热材料厚度的计算与下列哪几项有关？( )",[298,300,302,304],{"key":20,"text":299,"correct":29},"室内外温差",{"key":24,"text":301,"correct":29},"围护结构的总热阻",{"key":27,"text":303,"correct":29},"围护结构隔热层外各层材料的厚度",{"key":31,"text":305,"correct":29},"隔热材料的导热系数",{"id":307,"libraryId":5,"type":180,"typeLabel":181,"stem":33,"options":308,"answer":192,"analysis":33},880724,[309,311,313,315],{"key":20,"text":310,"correct":29},"5-6-10-9-5",{"key":24,"text":312,"correct":29},"4-7-6-4",{"key":27,"text":314,"correct":22},"4-5-6-7-4",{"key":31,"text":316,"correct":22},"5-6-7-11-10-9-5",{"id":318,"libraryId":5,"type":180,"typeLabel":181,"stem":319,"options":320,"answer":205,"analysis":33},880725,"下列哪几项不宜采用低温送风空气调节系统？( )",[321,323,325,327],{"key":20,"text":322,"correct":22},"采用冰蓄冷空调冷源",{"key":24,"text":324,"correct":22},"有低温冷源",{"key":27,"text":326,"correct":29},"需要较大换气量",{"key":31,"text":328,"correct":29},"需要保持较高空气湿度",{"id":330,"libraryId":5,"type":180,"typeLabel":181,"stem":331,"options":332,"answer":341,"analysis":33},880726,"机械循环热水供暖系统中通过某一环路的实际流量是由( )决定的。",[333,335,337,339],{"key":20,"text":334,"correct":22},"该系统的实际负荷",{"key":24,"text":336,"correct":29},"资用压差",{"key":27,"text":338,"correct":22},"该系统的供回水温差",{"key":31,"text":340,"correct":29},"该系统的阻抗","BD",{"id":343,"libraryId":5,"type":180,"typeLabel":181,"stem":344,"options":345,"answer":228,"analysis":33},880727,"除了围护结构传热量、人员和照明散热量外，夏季空调区得热量还包括( )。",[346,348,350,352],{"key":20,"text":347,"correct":29},"设备、器具、管道的散热量",{"key":24,"text":349,"correct":22},"室内湿衣服水分蒸发带给空气的潜热量",{"key":27,"text":351,"correct":29},"渗透空气带入的热量",{"key":31,"text":353,"correct":29},"食品或物料的散热量",{"id":355,"libraryId":5,"type":180,"typeLabel":181,"stem":356,"options":357,"answer":228,"analysis":33},880728,"关于下送风方式的说法中，不正确的是( )。",[358,360,362,364],{"key":20,"text":359,"correct":29},"下送风方式的送风温差减小、风量增加、因此其风系统的能耗增加",{"key":24,"text":361,"correct":22},"地板送风方式直接将新鲜的空气送入人员工作区，因此空气品质好",{"key":27,"text":363,"correct":29},"下送风方式可以实现分层空调，使系统能耗减少",{"key":31,"text":365,"correct":29},"下送风方式可能使系统能耗增加",{"id":367,"libraryId":5,"type":180,"typeLabel":181,"stem":368,"options":369,"answer":241,"analysis":33},880729,"多层公共建筑的通风、空调风管上所用的防火阀动作温度不应是( )。",[370,372,374,376],{"key":20,"text":371,"correct":22},"70℃",{"key":24,"text":373,"correct":29},"80℃",{"key":27,"text":375,"correct":29},"150℃",{"key":31,"text":377,"correct":29},"280℃",{"id":379,"libraryId":5,"type":180,"typeLabel":181,"stem":380,"options":381,"answer":192,"analysis":33},880730,"关于空调冷却水系统节能设计的观点，下列哪几项是不正确的？",[382,384,386,388],{"key":20,"text":383,"correct":29},"电动压缩制冷设备的冷却水系统应设计为变流量系统",{"key":24,"text":385,"correct":29},"冷却塔供冷可采用开式冷却塔直接供水",{"key":27,"text":387,"correct":22},"冷却塔应优先选用有布水压力要求的节能型产品",{"key":31,"text":389,"correct":22},"采暖室外计算温度在O℃以下的地区，冬季利用冷却塔供冷，应采用必要的防冻、保温措施",{"id":391,"libraryId":5,"type":180,"typeLabel":181,"stem":392,"options":393,"answer":254,"analysis":33},880731,"吸收式制冷系统主要设备有( )。",[394,396,398,400],{"key":20,"text":395,"correct":29},"冷凝器",{"key":24,"text":397,"correct":29},"蒸发器",{"key":27,"text":399,"correct":29},"吸收器",{"key":31,"text":401,"correct":29},"发生器",{"id":403,"libraryId":5,"type":180,"typeLabel":181,"stem":404,"options":405,"answer":254,"analysis":33},880732,"热水锅炉系统中，循环水泵的扬程应包括( )。",[406,408,410,412],{"key":20,"text":407,"correct":29},"热水锅炉水流压力下降",{"key":24,"text":409,"correct":29},"锅炉房内循环水管道系统的压力损失",{"key":27,"text":411,"correct":29},"锅炉房至最不利用户供回水管的压力损失",{"key":31,"text":413,"correct":29},"最不利用户内部系统的压力损失",{"id":415,"libraryId":5,"type":180,"typeLabel":181,"stem":416,"options":417,"answer":280,"analysis":33},880733,"计算冷风渗透耗热量常用的方法有( )。",[418,420,422,424],{"key":20,"text":419,"correct":29},"缝隙法",{"key":24,"text":421,"correct":29},"换气次数法",{"key":27,"text":423,"correct":29},"百分数法",{"key":31,"text":425,"correct":22},"外窗附加率法",{"id":427,"libraryId":5,"type":180,"typeLabel":181,"stem":428,"options":429,"answer":280,"analysis":33},880734,"选择和设置地漏时，下列措施正确的是( )。",[430,432,434,436],{"key":20,"text":431,"correct":29},"食堂、厨房和公共浴室等排水宜设置网框式地漏",{"key":24,"text":433,"correct":29},"地漏应设在易溅水的器具附近地面的最低处",{"key":27,"text":435,"correct":29},"地漏篦子顶面应低于最低地面5～10mm",{"key":31,"text":437,"correct":22},"直通式地漏下可以不设存水弯",{"id":439,"libraryId":5,"type":180,"typeLabel":181,"stem":440,"options":441,"answer":280,"analysis":33},880735,"对于同一个湿空气状态点，下列说法正确的是( )。",[442,444,446,448],{"key":20,"text":443,"correct":29},"湿球温度不可能高于干球温度",{"key":24,"text":445,"correct":29},"露点温度不可能高于湿球温度",{"key":27,"text":447,"correct":29},"露点温度不可能高于干球温度",{"key":31,"text":449,"correct":22},"湿球温度不可能低于0℃",{"id":451,"libraryId":5,"type":180,"typeLabel":181,"stem":452,"options":453,"answer":293,"analysis":33},880736,"关于水阀的选择，下列表述错误的是( )。",[454,456,458,460],{"key":20,"text":455,"correct":29},"可以采用调节阀代替开关阀",{"key":24,"text":457,"correct":29},"二通调节阀宜采用线性特性的",{"key":27,"text":459,"correct":22},"三通调节阀宜采用抛物线特性的",{"key":31,"text":461,"correct":29},"为了提高调节性能，阀门尺寸通常宜比管道管径小一号",{"id":463,"libraryId":5,"type":180,"typeLabel":181,"stem":464,"options":465,"answer":293,"analysis":33},880737,"下列隔振方法中，正确的是( )。",[466,468,470,472],{"key":20,"text":467,"correct":29},"水泵出口的止回阀，宜采用消锤式止回阀",{"key":24,"text":469,"correct":29},"设备运转的频率与弹性减振器垂直方向上的固有频率之比应不小于2.5",{"key":27,"text":471,"correct":22},"设备运转的频率与橡胶减振器垂直方向上的固有频率之比宜为2～3",{"key":31,"text":473,"correct":29},"受设备振动影响的管道应采用弹性支吊架",{"id":475,"libraryId":5,"type":180,"typeLabel":181,"stem":476,"options":477,"answer":486,"analysis":33},880738,"关于避风风帽，下列说法正确的是( )。",[478,480,482,484],{"key":20,"text":479,"correct":29},"避风风帽安装在自然排风系统的出口",{"key":24,"text":481,"correct":22},"避风风帽安装在自然排风系统的入口",{"key":27,"text":483,"correct":29},"它是利用风力造成的负压，加强排风能力的一种装置",{"key":31,"text":485,"correct":22},"它是利用风力造成的正压，加强排风能力的一种装置","AC",{"id":488,"libraryId":5,"type":180,"typeLabel":181,"stem":489,"options":490,"answer":205,"analysis":33},880739,"GB1355492中规定，下列哪几类高效过滤器出厂前进行检漏试验？",[491,493,495,497],{"key":20,"text":492,"correct":22},"A类过滤器",{"key":24,"text":494,"correct":22},"B类过滤器",{"key":27,"text":496,"correct":29},"C类过滤器",{"key":31,"text":498,"correct":29},"D类过滤器",{"id":500,"libraryId":5,"type":180,"typeLabel":181,"stem":501,"options":502,"answer":267,"analysis":33},880740,"末端均采用风机盘管加新风的空调方式，区域供冷集中空调与独栋楼集中空调方案相比，通常可以减少( )。",[503,505,507,509],{"key":20,"text":504,"correct":29},"制冷机房面积",{"key":24,"text":506,"correct":22},"夏季空调运行能耗",{"key":27,"text":508,"correct":22},"空调系统一次投资",{"key":31,"text":510,"correct":29},"空调设备的装机电量",{"id":512,"libraryId":5,"type":180,"typeLabel":181,"stem":513,"options":514,"answer":241,"analysis":33},880741,"室内干球温度和相对湿度一定，大气压力降低，下列表述中正确的是( )。",[515,517,519,521],{"key":20,"text":516,"correct":22},"湿球温度上升",{"key":24,"text":518,"correct":29},"含湿量增加",{"key":27,"text":520,"correct":29},"露点温度基本不变",{"key":31,"text":522,"correct":29},"比焓增加",{"id":524,"libraryId":5,"type":180,"typeLabel":181,"stem":525,"options":526,"answer":535,"analysis":33},880742,"居住建筑供暖设计计算建筑物内部得热时，下列哪几项是正确的？( )",[527,529,531,533],{"key":20,"text":528,"correct":22},"从建筑热负荷中扣除",{"key":24,"text":530,"correct":29},"不从建筑热负荷中扣除",{"key":27,"text":532,"correct":29},"对严寒、寒冷地区的住宅，应从建筑耗热量中扣除",{"key":31,"text":534,"correct":22},"均不从建筑耗热量中扣除","BC",{"id":537,"libraryId":5,"type":180,"typeLabel":181,"stem":538,"options":539,"answer":241,"analysis":33},880743,"关于中和面，下列说法正确的是( )。",[540,542,544,546],{"key":20,"text":541,"correct":22},"中和面的位置可任意选择",{"key":24,"text":543,"correct":29},"中和面上移，排风窗孔面积增大，进风窗孔面积减少",{"key":27,"text":545,"correct":29},"中和面下移，排风窗孔面积增大，进风窗孔面积减少",{"key":31,"text":547,"correct":29},"中和面上的余压为零",{"id":549,"libraryId":5,"type":180,"typeLabel":181,"stem":550,"options":551,"answer":192,"analysis":33},880744,"防烟楼梯间的加压送风系统，下列哪些做法是正确的？( )",[552,554,556,558],{"key":20,"text":553,"correct":29},"防烟楼梯间的余压值应为40～50Pa",{"key":24,"text":555,"correct":29},"防烟楼梯间宜每隔2～3层设置一个加压送风口",{"key":27,"text":557,"correct":22},"剪刀楼梯间应各自分别设置风道",{"key":31,"text":559,"correct":22},"防烟楼梯间及其前室如果都没有自然排烟条件，应分别设置加压送风口",{"id":561,"libraryId":5,"type":180,"typeLabel":181,"stem":562,"options":563,"answer":228,"analysis":33},880745,"关于冷热源及空调水系统的监测与控制，下列哪几项是正确的？",[564,566,568,570],{"key":20,"text":565,"correct":29},"冷热源机组的能量调节一般由机组自身的控制系统完成",{"key":24,"text":567,"correct":22},"冷水系统采用冷量来控制冷水机组及其对应的水泵、冷却塔的运行和运行台数",{"key":27,"text":569,"correct":29},"冷却塔风机的运行台数由冷却塔出水温度控制",{"key":31,"text":571,"correct":29},"变水量系统控制中，采用压差旁通控制，或是采用水泵变频控制，都应以水泵运行台数控制为优先",{"id":573,"libraryId":5,"type":180,"typeLabel":181,"stem":574,"options":575,"answer":267,"analysis":33},880746,"在设计冷库制冷系统时，需计算各种负荷，下列说法正确的是( )。",[576,578,580,582],{"key":20,"text":577,"correct":29},"计算冷间冷却设备负荷是为了选用或设计冷间内蒸发器容量",{"key":24,"text":579,"correct":22},"计算冷间机械负荷是为了选用或设计冷间内蒸发器容量",{"key":27,"text":581,"correct":22},"计算冷间冷却设备负荷是为了选用制冷压缩机",{"key":31,"text":583,"correct":29},"计算冷间机械负荷是为了选用制冷压缩机",{"id":585,"libraryId":5,"type":180,"typeLabel":181,"stem":586,"options":587,"answer":293,"analysis":33},880747,"关于卫生器具的水封说法，正确的是( )。",[588,590,592,594],{"key":20,"text":589,"correct":29},"卫生器具与生活污水管道或其他可能产生有害气体的排水管道直接连接时，必须在排水口以下设水封装置，其水封深度不得小于50mm",{"key":24,"text":591,"correct":29},"卫生器具与生活污水管道或其他可能产生有害气体的排水管道直接连接时，必须在排水口以下设水封装置，其水封深度不得小于30mm",{"key":27,"text":593,"correct":22},"坐便器等内置存水弯的卫生器具，不应在排水口以下再设水封装置",{"key":31,"text":595,"correct":29},"医院、教学、科研单位等有化学试剂排放的排水系统，不在同一房间内的卫生器具不得共用一个水封装置给水方式",{"id":597,"libraryId":5,"type":180,"typeLabel":181,"stem":598,"options":599,"answer":535,"analysis":33},880748,"下列( )制冷剂宜采用一次节流、不完全中间冷却的双级压缩制冷循环。",[600,602,604,606],{"key":20,"text":601,"correct":22},"R717",{"key":24,"text":603,"correct":29},"R22",{"key":27,"text":605,"correct":29},"R134a",{"key":31,"text":607,"correct":22},"R717和R22",{"id":609,"libraryId":5,"type":180,"typeLabel":181,"stem":610,"options":611,"answer":228,"analysis":33},880749,"在防止冬季围护结构内表面结露的下列措施中哪些是有效的？( )",[612,614,616,618],{"key":20,"text":613,"correct":29},"增加围护结构的传热阻",{"key":24,"text":615,"correct":22},"增加围护结构内表面的换热阻",{"key":27,"text":617,"correct":29},"降低室内空气的含湿量",{"key":31,"text":619,"correct":29},"提高室内温度",{"id":621,"libraryId":5,"type":180,"typeLabel":181,"stem":622,"options":623,"answer":486,"analysis":33},880750,"在溴化锂吸收式冷水机组的安全保护装置中，不应设置的是下列哪几项？",[624,626,628,630],{"key":20,"text":625,"correct":29},"吸气低压保护",{"key":24,"text":627,"correct":22},"冷水低温保护",{"key":27,"text":629,"correct":29},"压缩机过流保护",{"key":31,"text":631,"correct":22},"防结晶保护",[633,636,639,642,645,648],{"id":15,"name":634,"category":7,"favorite":635},"领导干部任职前廉政法规知识测试题",92,{"id":637,"name":638,"category":7,"favorite":15},595,"建筑结构与设备",{"id":640,"name":641,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":643,"name":644,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":646,"name":647,"category":7,"favorite":8},534,"BIM工程师",{"id":649,"name":647,"category":7,"favorite":8},535]