[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-17":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":608},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,17,50,2054,[13,34,46,58,70,82,93,105,117,129,141,153,162,174,186,198,210,222,234,246,258,270,282,294,306,318,330,338,350,362,374,386,398,410,422,434,446,456,467,479,490,502,514,526,538,550,562,573,584,596],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},880651,1,"单选题","人体所处热环境在其他条件不变的情况下，下列因素改变，不能增加人体冷热感的应是哪一项？( )",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","室内空气温度降低",false,{"key":24,"text":25,"correct":22},"B","围护结构内表面温度降低",{"key":27,"text":28,"correct":29},"C","增大新风量",true,{"key":31,"text":32,"correct":22},"D","夏季高温时减小室内相对湿度","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},880652,"供暖散热器的构造因素中，对散热器的散热效果无影响的应是下列哪一项？( )",[38,40,42,44],{"key":20,"text":39,"correct":22},"散热器的材料性质",{"key":24,"text":41,"correct":22},"散热器的外形尺寸",{"key":27,"text":43,"correct":22},"散热器的表面装饰",{"key":31,"text":45,"correct":29},"散热器的承压大小",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},880653,"对空气进行舒适性调节，有外墙时地面传热形成的冷负荷应( )。",[50,52,54,56],{"key":20,"text":51,"correct":29},"不必计算",{"key":24,"text":53,"correct":22},"计算距墙2m以内的地面传热形成的冷负荷",{"key":27,"text":55,"correct":22},"按照地带法计算",{"key":31,"text":57,"correct":22},"计算距墙4m以内的地面传热形成的冷负荷",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},880654,"导致贮藏果蔬干耗的因素是( )。",[62,64,66,68],{"key":20,"text":63,"correct":22},"呼吸作用和空气湿度",{"key":24,"text":65,"correct":22},"空气的温度和湿度",{"key":27,"text":67,"correct":22},"空气的流速和果蔬的包装",{"key":31,"text":69,"correct":29},"呼吸作用和贮藏环境条件",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},880655,"设置集中采暖的建筑物中，安装在有冻结危险的楼梯间的散热器，下列哪一项是正确的连接方式？",[74,76,78,80],{"key":20,"text":75,"correct":22},"由散热器前设置调节阀的单独立、支管采暖",{"key":24,"text":77,"correct":29},"由散热器前不设置调节阀的单独立、支管采暖",{"key":27,"text":79,"correct":22},"楼梯间与相邻房间公用立管、支管，立管、支管均设置调节阀",{"key":31,"text":81,"correct":22},"楼梯间与相邻房间公用立管，仅相邻房间的支管设置调节阀",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":84,"answer":24,"analysis":33},880656,[85,87,89,91],{"key":20,"text":86,"correct":22},"严重污染区",{"key":24,"text":88,"correct":29},"工业区",{"key":27,"text":90,"correct":22},"城市郊区",{"key":31,"text":92,"correct":22},"清洁区",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":31,"analysis":33},880657,"采用气压给水设备的供水系统，加压水泵在气压罐平均压力点的流量应按( )确定。",[97,99,101,103],{"key":20,"text":98,"correct":22},"不应小于平均小时用水量",{"key":24,"text":100,"correct":22},"不应小于最大小时用水量",{"key":27,"text":102,"correct":22},"不应小于设计秒流量",{"key":31,"text":104,"correct":29},"不应小于最大小时用水量的1.2倍",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":31,"analysis":33},880658,"关于机械全面通风的计算方法，下列哪一项正确？",[109,111,113,115],{"key":20,"text":110,"correct":22},"当数种溶剂(苯及同系物或醇类或醋酸类)的蒸气同时在室内散发时，全面通风量应取其各项所需通风量的最大值",{"key":24,"text":112,"correct":22},"计算风量平衡时应采用体积流量",{"key":27,"text":114,"correct":22},"利用无组织进风，可让清洁要求高的房间保持正压",{"key":31,"text":116,"correct":29},"同时放散热、蒸汽和有害气体的工业建筑，除局部排风外，宜从上部区域全面排风，当房间高度大于6m时，排风量可按6m3\u002F(h·㎡)计算",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":20,"analysis":33},880659,"载冷剂是( )。",[121,123,125,127],{"key":20,"text":122,"correct":29},"间接制冷系统中传递热量的物质",{"key":24,"text":124,"correct":22},"在冷凝器中被冷却",{"key":27,"text":126,"correct":22},"制冷系统中直接传递热量的物质",{"key":31,"text":128,"correct":22},"在蒸发器中被加热",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":27,"analysis":33},880660,"根据建筑节能工程施工质量验收的有关规定，进行系统风量平衡调试时风口风量与设计风量的允许偏差( )。",[133,135,137,139],{"key":20,"text":134,"correct":22},"不大于5%",{"key":24,"text":136,"correct":22},"不大于10%",{"key":27,"text":138,"correct":29},"不大于15%",{"key":31,"text":140,"correct":22},"不大于20%",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":31,"analysis":33},880661,"通风柜的排风方式，下列哪一项是错误的？( )",[145,147,149,151],{"key":20,"text":146,"correct":22},"冷过程用下部排风",{"key":24,"text":148,"correct":22},"热过程用上部排风",{"key":27,"text":150,"correct":22},"发热量不稳定过程，上下设排风口",{"key":31,"text":152,"correct":29},"排除热的有害气体时，排风口应设在下部",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":31,"analysis":33},880662,"某住宅楼地下车库面积1750㎡，高4m，按相关规范要求，下列哪一项是正确的？( )",[157,158,159,160],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":31,"text":161,"correct":29},"可不设机械排烟",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":24,"analysis":33},880663,"层高超过4m的建筑物或房间计算天窗的耗热量时，冬季室内计算温度应采用( )。",[166,168,170,172],{"key":20,"text":167,"correct":22},"工作地点的温度",{"key":24,"text":169,"correct":29},"屋顶下的温度",{"key":27,"text":171,"correct":22},"室内平均温度",{"key":31,"text":173,"correct":22},"天窗处的温度",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":24,"analysis":33},880664,"地埋管地源热泵空调系统设计应进行全年供暖空调动态负荷计算，最小计算周期宜为( )。",[178,180,182,184],{"key":20,"text":179,"correct":22},"0.5a",{"key":24,"text":181,"correct":29},"1a",{"key":27,"text":183,"correct":22},"2a",{"key":31,"text":185,"correct":22},"3a",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":24,"analysis":33},880665,"在计算住宅分户热计量系统的基本热负荷时，其室内温度应( )。",[190,192,194,196],{"key":20,"text":191,"correct":22},"按相应设计标准提高1℃",{"key":24,"text":193,"correct":29},"按相应设计标准提高2℃",{"key":27,"text":195,"correct":22},"和原有设计标准相同",{"key":31,"text":197,"correct":22},"按相应设计标准降低1℃",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":27,"analysis":33},880666,"对于二类高层建筑，有500㎡的区域设有自动喷水灭火系统，包含此区域的防火分区的最大允许建筑面积为( )。",[202,204,206,208],{"key":20,"text":203,"correct":22},"1000㎡",{"key":24,"text":205,"correct":22},"1500㎡",{"key":27,"text":207,"correct":29},"2000㎡",{"key":31,"text":209,"correct":22},"3000㎡",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":24,"analysis":33},880667,"位于严寒地区的某车间采用集中送热风供暖，并且不设置值班供暖散热器，则( )。",[214,216,218,220],{"key":20,"text":215,"correct":22},"送风温度不得超过80℃",{"key":24,"text":217,"correct":29},"热风供暖系统不宜少于两个",{"key":27,"text":219,"correct":22},"气流组织应保证距外窗2m以内工作岗位温度",{"key":31,"text":221,"correct":22},"送风射流宜直接到达工作区",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":24,"analysis":33},880668,"冰蓄冷与水蓄冷是蓄能空调的两种主要形式。水蓄冷与冰蓄冷相比，水蓄冷的优势为下列哪一项？",[226,228,230,232],{"key":20,"text":227,"correct":22},"蓄冷密度更大",{"key":24,"text":229,"correct":29},"维护费用更低",{"key":27,"text":231,"correct":22},"冷损耗更小",{"key":31,"text":233,"correct":22},"冷冻水温度更低",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":20,"analysis":33},880669,"装配式冷库按使用场所不同，分为( )。",[238,240,242,244],{"key":20,"text":239,"correct":29},"室内型和室外型",{"key":24,"text":241,"correct":22},"高温型和低温型",{"key":27,"text":243,"correct":22},"冷藏型和冻结型",{"key":31,"text":245,"correct":22},"单间型和分隔型",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":20,"analysis":33},880670,"根据消防设计规范，以下关于机械排烟系统排烟风机设置的叙述，哪一项是正确的？",[250,252,254,256],{"key":20,"text":251,"correct":29},"排烟风机的全压应满足排烟系统最不利环路的要求",{"key":24,"text":253,"correct":22},"排烟风机的风量应考虑25%的漏风量",{"key":27,"text":255,"correct":22},"排烟风机必须采用钢制离心风机",{"key":31,"text":257,"correct":22},"排烟风机应设在风机房内",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":27,"analysis":33},880671,"多联式空调机组室外机与室内机接管长度为20m，其他条件与额定工况相同，下列说法中正确的是( )。",[262,264,266,268],{"key":20,"text":263,"correct":22},"实际能效比大于额定能效比",{"key":24,"text":265,"correct":22},"实际能效比等于额定能效比",{"key":27,"text":267,"correct":29},"实际能效比小于额定能效比",{"key":31,"text":269,"correct":22},"无法判断",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":31,"analysis":33},880672,"当冷水机组蒸发器侧和冷凝器侧的水侧污垢系数均为0.13㎡·℃\u002FkW时，与该机组的名义工况相比较，下列表述中哪一项错误？",[274,276,278,280],{"key":20,"text":275,"correct":22},"机组蒸发温度下降",{"key":24,"text":277,"correct":22},"机组制冷量下降",{"key":27,"text":279,"correct":22},"机组性能系数下降",{"key":31,"text":281,"correct":29},"机组冷凝温度下降",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":31,"analysis":33},880673,"下列空调节能设计措施中，不一定合适的是( )。",[286,288,290,292],{"key":20,"text":287,"correct":22},"合理确定室内设计参数",{"key":24,"text":289,"correct":22},"进行空调系统方案的优化选择",{"key":27,"text":291,"correct":22},"进行设备台数的合理配置",{"key":31,"text":293,"correct":29},"按额定能效比最高来选择空调设备",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":27,"analysis":33},880674,"关于吊顶辐射空调方式，下列说法中正确的是( )。",[298,300,302,304],{"key":20,"text":299,"correct":22},"夏季水温提高冷却能力急剧降低，因此夏季供水温度应尽可能降低",{"key":24,"text":301,"correct":22},"冬季辐射吊顶通过辐射方式直接将热量传给人体，使人感到舒适",{"key":27,"text":303,"correct":29},"吊顶辐射空调不适用于热湿负荷较大的情况",{"key":31,"text":305,"correct":22},"室内辐射吊顶可以负担室内全部空调冷负荷",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":24,"analysis":33},880675,"某大型超市采用接风管的屋顶式风冷空调(热泵)机组，机组的名义制冷量为200kW。对该机组的要求，不符合国家有关标准的应是下列哪一项？( )",[310,312,314,316],{"key":20,"text":311,"correct":22},"机组能效比(EER)的等级应不低于4级",{"key":24,"text":313,"correct":29},"机组的最小机外静压值应不低于500Pa",{"key":27,"text":315,"correct":22},"机组的噪声值由制造厂确定，并在产品样本中提供",{"key":31,"text":317,"correct":22},"机组在名义工况下，其制冷量、制热量不小于名义规定值的95%",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":31,"analysis":33},880676,"某房间机械送风量为1800m3\u002Fh，机械排风量为2000m3\u002Fh，说法正确的是哪一项？",[322,324,326,328],{"key":20,"text":323,"correct":22},"房间形成正压，自然排风量为200m3\u002Fh",{"key":24,"text":325,"correct":22},"房间形成负压，自然进风量为200m3\u002Fh",{"key":27,"text":327,"correct":22},"房间形成正压，自然进风量为200m3\u002Fh",{"key":31,"text":329,"correct":29},"条件不明确，正负压及相应的自然通风量无法确定",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":31,"analysis":33},880677,"在锅炉房的油泵间设置机械通风装置，其换气次数应是下列哪一项？( )",[334,335,336,337],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":31,"text":33,"correct":29},{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":20,"analysis":33},880678,"下列关于蒸汽采暖系统中疏水器作用的说法正确的是( )。",[342,344,346,348],{"key":20,"text":343,"correct":29},"排出用热设备及管道中的凝结水，阻止蒸汽和空气通过",{"key":24,"text":345,"correct":22},"排出用热设备及管道中的蒸汽和空气，阻止凝结水通过",{"key":27,"text":347,"correct":22},"排出用热设备及管道中的空气，阻止蒸汽和凝结水通过",{"key":31,"text":349,"correct":22},"排出用热设备及管道中的凝结水和空气，阻止蒸汽通过",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":27,"analysis":33},880679,"独立水喷雾灭火系统，包括加压水泵、报警阀组、配水管网和水雾喷头，可不在此系统中设置的组件是下列哪一项？( )",[354,356,358,360],{"key":20,"text":355,"correct":22},"信号阀",{"key":24,"text":357,"correct":22},"压力开关",{"key":27,"text":359,"correct":29},"水流指示器",{"key":31,"text":361,"correct":22},"水力警铃",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":27,"analysis":33},880680,"消防机械加压系统的室外进风口、室外排烟补风口、室外排烟口的布置要求是( )。",[366,368,370,372],{"key":20,"text":367,"correct":22},"机械加压系统的室外进风口和排烟补风口应布置在排烟口的上方，高差不宜小于3m，水平布置时距离不宜小于10m",{"key":24,"text":369,"correct":22},"机械加压系统的室外进风口应布置在排烟补风口和排烟口的上方，高差不宜小于5m，水平布置时距离不宜小于12m",{"key":27,"text":371,"correct":29},"机械加压系统的室外进风口应布置在排烟补风口和排烟口的下方，高差不宜小于3m，水平布置时距离不宜小于10m",{"key":31,"text":373,"correct":22},"机械加压系统的室外进风口和排烟口应布置在排烟补风口的下方，高差不宜小于5m，水平布置时距离不宜小于12m",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":27,"analysis":33},880681,"以采暖系统为主要用热的工厂厂区，采用热媒时，下列选项的哪一个为宜？",[378,380,382,384],{"key":20,"text":379,"correct":22},"60～50℃",{"key":24,"text":381,"correct":22},"95～70℃",{"key":27,"text":383,"correct":29},"130～80℃",{"key":31,"text":385,"correct":22},"蒸汽",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":27,"analysis":33},880682,"下列关于溴化锂吸收式制冷机的热力系数的表达不正确的是( )。",[390,392,394,396],{"key":20,"text":391,"correct":22},"热力系数是制冷机经济性的评价指标",{"key":24,"text":393,"correct":22},"热力系数是制冷机获得的冷量与消耗的热量之比",{"key":27,"text":395,"correct":29},"热力系数随热媒温度升高而增大",{"key":31,"text":397,"correct":22},"和压缩式制冷机中卡诺循环的制冷系数是理论上最大的制冷系数相对应，热力系数也有理论上最大热力系数的概念",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":20,"analysis":33},880683,"下列空调系统的加湿方法，哪一种不属于等焓加湿？( )",[402,404,406,408],{"key":20,"text":403,"correct":29},"电极式加湿器加湿",{"key":24,"text":405,"correct":22},"高压喷雾加湿器加湿",{"key":27,"text":407,"correct":22},"超声波加湿器加湿",{"key":31,"text":409,"correct":22},"湿膜加湿器加湿",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":31,"analysis":33},880684,"两个热水供暖的并联环路(不包括共同段)，根据各个环路压力损失大小需要采取平衡措施的应是下列哪一项？( )",[414,416,418,420],{"key":20,"text":415,"correct":22},"18kPa和16.5kPa",{"key":24,"text":417,"correct":22},"18kPa和17.5kPa",{"key":27,"text":419,"correct":22},"18kPa和20.5kPa",{"key":31,"text":421,"correct":29},"18kPa和21.5kPa",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":27,"analysis":33},880685,"当空气达到饱和状态时，下列哪一项是错误的？( )",[426,428,430,432],{"key":20,"text":427,"correct":22},"空气的干球温度等于其湿球温度",{"key":24,"text":429,"correct":22},"空气的湿球温度等于其露点温度",{"key":27,"text":431,"correct":29},"空气的干球温度高于其露点温度",{"key":31,"text":433,"correct":22},"空气的相对湿度达到100%",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":20,"analysis":33},880686,"闭式喷水灭火系统应在( )设置末端试水装置。",[438,440,442,444],{"key":20,"text":439,"correct":29},"每个防火分区的最不利点喷头处",{"key":24,"text":441,"correct":22},"每层最不利点喷头处",{"key":27,"text":443,"correct":22},"每个报警阀组控制的最不利点喷头处",{"key":31,"text":445,"correct":22},"喷水灭火系统的最高处",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":27,"analysis":33},880687,"利用天窗排风的工业建筑，应设置避风天窗的是( )。",[450,452,453,454],{"key":20,"text":451,"correct":22},"夏季室外平均风速小于1m\u002Fs的工业建筑",{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":29},{"key":31,"text":455,"correct":22},"多跨厂房处于动力阴影区的厂房天窗",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":458,"answer":31,"analysis":33},880688,[459,461,463,465],{"key":20,"text":460,"correct":22},"a，b，c，d",{"key":24,"text":462,"correct":22},"a，b，c",{"key":27,"text":464,"correct":22},"b，c，a",{"key":31,"text":466,"correct":29},"c，d",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":27,"analysis":33},880689,"设置集中采暖且有排风的建筑，进行热平衡计算时，下列哪一项是不正确的？",[471,473,475,477],{"key":20,"text":472,"correct":22},"对于稀释有害物质的全面通风的进风，采用冬季采暖室外计算温度",{"key":24,"text":474,"correct":22},"对于消除余热余湿的全面通风，采用冬季通风室外计算温度",{"key":27,"text":476,"correct":29},"对于局部排风的补风，采用冬季通风计算温度",{"key":31,"text":478,"correct":22},"对于局部排风的补风，采用冬季采暖计算温度",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":481,"answer":31,"analysis":33},880690,[482,484,486,488],{"key":20,"text":483,"correct":22},"排水管直径太小",{"key":24,"text":485,"correct":22},"排水口位置偏高",{"key":27,"text":487,"correct":22},"风机的负压偏小",{"key":31,"text":489,"correct":29},"机组的排水管管口直通机房",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":27,"analysis":33},880691,"按照建筑范围划分，通风方式可分为( )。",[494,496,498,500],{"key":20,"text":495,"correct":22},"自然通风和机械通风",{"key":24,"text":497,"correct":22},"工业通风和民用通风",{"key":27,"text":499,"correct":29},"全面通风和局部通风",{"key":31,"text":501,"correct":22},"净化通风和除尘",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":31,"analysis":33},880692,"高压蒸汽最不利环路供汽管的压力损失，不应大于起始压力的( )。",[506,508,510,512],{"key":20,"text":507,"correct":22},"10%",{"key":24,"text":509,"correct":22},"15%",{"key":27,"text":511,"correct":22},"20%",{"key":31,"text":513,"correct":29},"25%",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":20,"analysis":33},880693,"溴化锂吸收式制冷机中，设置抽气装置的主要目的是( )。",[518,520,522,524],{"key":20,"text":519,"correct":29},"抽除不凝性气体",{"key":24,"text":521,"correct":22},"抽除水蒸气",{"key":27,"text":523,"correct":22},"防止结晶",{"key":31,"text":525,"correct":22},"提高系统真空度",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":24,"analysis":33},880694,"氟利昂制冷系统(如R22系统)的制冷剂管道应采用( )。",[530,532,534,536],{"key":20,"text":531,"correct":22},"紫铜管或焊接钢管",{"key":24,"text":533,"correct":29},"紫铜管或无缝钢管",{"key":27,"text":535,"correct":22},"无缝钢管或焊接钢管",{"key":31,"text":537,"correct":22},"紫铜管或镀锌钢管",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":20,"analysis":33},880695,"视为比空气轻的气体，是指相对密度要小于或等于下列哪一项数值？( )",[542,544,546,548],{"key":20,"text":543,"correct":29},"0.75",{"key":24,"text":545,"correct":22},"0.80",{"key":27,"text":547,"correct":22},"1.10",{"key":31,"text":549,"correct":22},"1.20",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":20,"analysis":33},880696,"吸收制冷循环倍率是指( )之比。",[554,556,558,560],{"key":20,"text":555,"correct":29},"制冷剂十吸收剂质量流量与制冷剂质量流量",{"key":24,"text":557,"correct":22},"吸收剂质量流量与制冷剂质量流量",{"key":27,"text":559,"correct":22},"制冷剂质量流量与制冷剂十吸收剂质量流量",{"key":31,"text":561,"correct":22},"制冷剂质量流量与吸收剂质量流量",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":564,"answer":20,"analysis":33},880697,[565,567,569,571],{"key":20,"text":566,"correct":29},"静态压力为26m，用户2采用分区连接，低区直接连接，高区双水箱连接，其他用户直接连接",{"key":24,"text":568,"correct":22},"静态压力为26m，用户2采用分区连接，低区直接连接，高区间接连接，其他用户直接连接",{"key":27,"text":570,"correct":22},"静态压力为38m，所有用户直接连接",{"key":31,"text":572,"correct":22},"静态压力为26m，用户2采用分区连接，低区直接连接，高区间接连接，其他用户间接连接",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":575,"answer":24,"analysis":33},880698,[576,578,580,582],{"key":20,"text":577,"correct":22},"相同",{"key":24,"text":579,"correct":29},"人工焦炉煤气最大",{"key":27,"text":581,"correct":22},"天然气最大",{"key":31,"text":583,"correct":22},"液化石油气最大",{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":31,"analysis":33},880699,"因制冷剂R22与润滑油有一定相溶性，在设计制冷管路系统时应注意下列哪一项问题？( )",[588,590,592,594],{"key":20,"text":589,"correct":22},"不考虑润滑油问题",{"key":24,"text":591,"correct":22},"应考虑满液式蒸发器回油和压缩机出口润滑油分离问题",{"key":27,"text":593,"correct":22},"应考虑压缩机吸气管回油问题",{"key":31,"text":595,"correct":29},"应考虑蒸发器、压缩机吸气管回油和压缩机出口润滑油分离问题",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":20,"analysis":33},880700,"排烟风机应保证在280℃时能连续工作( )。",[600,602,604,606],{"key":20,"text":601,"correct":29},"30min",{"key":24,"text":603,"correct":22},"1h",{"key":27,"text":605,"correct":22},"1.5h",{"key":31,"text":607,"correct":22},"2h",[609,612,615,618,621,624],{"id":15,"name":610,"category":7,"favorite":611},"领导干部任职前廉政法规知识测试题",92,{"id":613,"name":614,"category":7,"favorite":15},595,"建筑结构与设备",{"id":616,"name":617,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":619,"name":620,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":622,"name":623,"category":7,"favorite":8},534,"BIM工程师",{"id":625,"name":623,"category":7,"favorite":8},535]