[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-16":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":619},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,16,50,2054,[13,35,48,61,74,88,100,112,124,137,149,161,174,186,198,210,222,234,246,258,271,284,296,308,320,332,344,356,367,379,391,403,415,427,435,447,459,467,479,491,503,515,526,538,550,559,571,583,595,607],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},880601,2,"多选题","关于制冷剂R134a，下列哪几种说法是正确的？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","与R12相比，在蒸发器和冷凝器中的放热系数较高",true,{"key":24,"text":25,"correct":26},"B","配用的润滑油与R12相同",false,{"key":28,"text":29,"correct":22},"C","对系统干燥和清洁度要求比R12高",{"key":31,"text":32,"correct":26},"D","对环境无危害","AC","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},880602,"某建筑采暖系统热用户与热水外网采用间接连接的原因，可能是下列哪几项？",[39,41,43,45],{"key":20,"text":40,"correct":22},"用户入口处压力超过该用户散热器承压",{"key":24,"text":42,"correct":22},"多层建筑群中的高层建筑",{"key":28,"text":44,"correct":26},"间接连接比直接连接费用低",{"key":31,"text":46,"correct":22},"外网水质不满足用户要求","ABD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},880603,"对外墙外保温技术和内保温技术在同等条件下进行比较，说法正确的应是下列哪几项？( )",[52,54,56,58],{"key":20,"text":53,"correct":26},"内保温更易避免热桥",{"key":24,"text":55,"correct":22},"外保温更易提高室内的热稳定性",{"key":28,"text":57,"correct":26},"外保温的隔热效果更佳",{"key":31,"text":59,"correct":22},"主体结构和保温材料相同时，外保温与内保温的外墙平均传热系数相同","BD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},880604,"确定气流组织形式时，下列因素中应考虑( )。",[65,67,69,71],{"key":20,"text":66,"correct":22},"空调冷源情况",{"key":24,"text":68,"correct":22},"照明散热情况",{"key":28,"text":70,"correct":22},"人员活动情况",{"key":31,"text":72,"correct":26},"风系统的阻力情况","ABC",{"id":75,"libraryId":5,"type":76,"typeLabel":77,"stem":78,"options":79,"answer":28,"analysis":34},880605,1,"单选题","在设计某办公楼机械循环热水供暖系统时，下列何项措施符合节能要求?( )。",[80,82,84,86],{"key":20,"text":81,"correct":26},"系统南北分环布置，采用单管系统并加设恒温阀",{"key":24,"text":83,"correct":26},"系统南北分环布置，采用单管系统并加跨越管",{"key":28,"text":85,"correct":22},"系统南北分环布置，采用双管系统并加恒温阀",{"key":31,"text":87,"correct":26},"系统南北分环布置，根据水力平衡要求在分环回水支管上设置水力平衡阀",{"id":89,"libraryId":5,"type":76,"typeLabel":77,"stem":90,"options":91,"answer":28,"analysis":34},880606,"排水塑料立管宜每( )设检查口。",[92,94,96,98],{"key":20,"text":93,"correct":26},"3层",{"key":24,"text":95,"correct":26},"4层",{"key":28,"text":97,"correct":22},"5层",{"key":31,"text":99,"correct":26},"6层",{"id":101,"libraryId":5,"type":76,"typeLabel":77,"stem":102,"options":103,"answer":28,"analysis":34},880607,"下列哪一项原因不会导致某空调系统用冷却塔的出水温度过高？",[104,106,108,110],{"key":20,"text":105,"correct":26},"循环水量过大",{"key":24,"text":107,"correct":26},"冷却塔风机风量不足",{"key":28,"text":109,"correct":22},"室外空气的湿球温度过低",{"key":31,"text":111,"correct":26},"布水不均匀",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":47,"analysis":34},880608,"下列关于不同类型空调系统的表述，哪几项是正确的？",[116,118,120,122],{"key":20,"text":117,"correct":22},"承担多房间的定风量全空气系统(无末端再热)，各个房间热湿负荷不同步变化时，难于同时保障各个房间要求的温度和湿度",{"key":24,"text":119,"correct":22},"无末端再热的变风量箱可通过调节风量保障承担区域的温度，但难于同时保证承担区域的湿度",{"key":28,"text":121,"correct":26},"既有内区又有外区房间的同一楼层采用风机盘管十新风空调系统时，内区房间与外区房间的新风机组分设，共用供水立管，该方案可保证冬季内区房间不过热",{"key":31,"text":123,"correct":22},"采用多联机的建筑，其直接膨胀式新风机组不宜与室内机共用室外机",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":136,"analysis":34},880609,"下列关于置换通风的说法，正确的是哪几项?( )。",[128,130,132,134],{"key":20,"text":129,"correct":22},"置换通风不适用在冬季有大量热负荷需要的建筑物外区",{"key":24,"text":131,"correct":26},"置换通风计算，只针对主要影响室内热舒适的温度进行计算",{"key":28,"text":133,"correct":26},"夏季置换通风送风温度不宜低于16℃",{"key":31,"text":135,"correct":22},"设计中，要避免置换通风与其他气流组织应用于同一空调区","AD",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":47,"analysis":34},880610,"在计算夏季空调房间的热湿比时，应该包括在计算之列的为下列哪几项？( )",[141,143,145,147],{"key":20,"text":142,"correct":22},"室内人员散湿",{"key":24,"text":144,"correct":22},"室内人员的潜热",{"key":28,"text":146,"correct":26},"新风带入的显热",{"key":31,"text":148,"correct":22},"与非空调区相邻隔墙传热",{"id":150,"libraryId":5,"type":76,"typeLabel":77,"stem":151,"options":152,"answer":31,"analysis":34},880611,"制造厂家提供的风冷冷水(热泵)机组产品噪声值，一般是在( )处的噪声值。",[153,155,157,159],{"key":20,"text":154,"correct":26},"距机组1.5m、距地面1.5m",{"key":24,"text":156,"correct":26},"距机组1m、距地面1m",{"key":28,"text":158,"correct":26},"距机组1.5m、距地面1m",{"key":31,"text":160,"correct":22},"距机组1m、距地面1.5m",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":173,"analysis":34},880612,"下列哪些蓄冰方式属于动态蓄冰？( )",[165,167,169,171],{"key":20,"text":166,"correct":26},"封装冰",{"key":24,"text":168,"correct":26},"冰盘管",{"key":28,"text":170,"correct":22},"冰片滑落式",{"key":31,"text":172,"correct":22},"冰晶式","CD",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":47,"analysis":34},880613,"对于制冷剂的要求，下列说法正确的是( )。",[178,180,182,184],{"key":20,"text":179,"correct":22},"对大气臭氧层没有破坏作用，对人体无害，无燃烧和爆炸危险，使用安全",{"key":24,"text":181,"correct":22},"通常要求制冷剂的单位容积制冷量要大，这样可以缩小压缩机的尺寸",{"key":28,"text":183,"correct":26},"制冷剂的密度应尽可能大，以减少压缩机尺寸",{"key":31,"text":185,"correct":22},"热导率要大，可以提高热交换设备的传热系数，减少传热面积，使热交换器耗用的金属材料减少",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":173,"analysis":34},880614,"一高精度空调系统，其送风支管上设置了1kW的电加热器。风管采用橡塑材料保温，沿气流方向，电加热器的前后一定长度范围内的风管上则采用铝箔离心玻璃棉保温。根据现行消防设计规范，该长度范围正确的应是下列哪几项？( )",[190,192,194,196],{"key":20,"text":191,"correct":26},"前0.8m，后0.5m",{"key":24,"text":193,"correct":26},"前0.5m，后0.8m",{"key":28,"text":195,"correct":22},"前0.8m，后0.8m",{"key":31,"text":197,"correct":22},"前0.8m，后1.0m",{"id":199,"libraryId":5,"type":76,"typeLabel":77,"stem":200,"options":201,"answer":20,"analysis":34},880615,"外墙与屋面的热桥部位的内表面温度不低于( )。",[202,204,206,208],{"key":20,"text":203,"correct":22},"室内空气露点温度",{"key":24,"text":205,"correct":26},"室外综合温度",{"key":28,"text":207,"correct":26},"室内湿球温度",{"key":31,"text":209,"correct":26},"室内干球温度",{"id":211,"libraryId":5,"type":76,"typeLabel":77,"stem":212,"options":213,"answer":20,"analysis":34},880616,"室内空气温度梯度大小与采用的供暖系统有关，温度梯度由大变小的为下列哪一项？( )",[214,216,218,220],{"key":20,"text":215,"correct":22},"热风供暖.散热器供暖.顶板辐射.地板辐射",{"key":24,"text":217,"correct":26},"顶板辐射.地板辐射.热风供暖.散热器供暖",{"key":28,"text":219,"correct":26},"散热器供暖.热风供暖.顶板辐射.地板辐射",{"key":31,"text":221,"correct":26},"地板辐射.散热器供暖.顶板辐射.热风供暖",{"id":223,"libraryId":5,"type":76,"typeLabel":77,"stem":224,"options":225,"answer":28,"analysis":34},880617,"在额定工况下进行风机盘管的性能测试，根据下列测试结果，可以判断哪一项是合格的？( )",[226,228,230,232],{"key":20,"text":227,"correct":26},"风量为额定值的94%",{"key":24,"text":229,"correct":26},"水阻力为额定值的120%",{"key":28,"text":231,"correct":22},"供冷量为额定值的95%",{"key":31,"text":233,"correct":26},"工作压力为0.6MPa，按0.9MPa进行盘管的气压浸水试验，保持5min不渗漏",{"id":235,"libraryId":5,"type":76,"typeLabel":77,"stem":236,"options":237,"answer":24,"analysis":34},880618,"燃油锅炉的燃料输送系统一般由( )组成。",[238,240,242,244],{"key":20,"text":239,"correct":26},"日用油箱、油泵、油罐、油流动驱动设备等",{"key":24,"text":241,"correct":22},"油泵、油罐、油管、过滤器、日用油箱等",{"key":28,"text":243,"correct":26},"提升机、油罐、油泵等",{"key":31,"text":245,"correct":26},"油罐、过滤器、提升机、日用油箱",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":73,"analysis":34},880619,"在防火阀和排烟阀(口)选择应用中，下列哪几项是正确的？( )",[250,252,254,256],{"key":20,"text":251,"correct":22},"防烟防火阀为70℃常开",{"key":24,"text":253,"correct":22},"排烟防火阀为280℃常闭",{"key":28,"text":255,"correct":22},"防火风口为70℃常开",{"key":31,"text":257,"correct":26},"排烟阀(口)为280℃常闭",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":270,"analysis":34},880620,"下列哪几项设计阶段不参评？( )",[262,264,266,268],{"key":20,"text":263,"correct":26},"新建的公共建筑，冷热源、输配系统和照明等各部分能耗进行独立分项计量",{"key":24,"text":265,"correct":22},"施工现场500km以内生产的建筑材料重量占建筑材料总重量的60%以上",{"key":28,"text":267,"correct":22},"室内游离甲醛、苯、氨、氡和TVOC等空气污染物浓度符合GB50325-2001《民用建筑工程室内环境污染控制规范》中的有关规定",{"key":31,"text":269,"correct":22},"办公、商场类建筑耗电、冷热量等实行计量收费","BCD",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":283,"analysis":34},880621,"不透明围护结构内的空气间层由“密闭”改为“通风”时，会使( )。",[275,277,279,281],{"key":20,"text":276,"correct":26},"冬季供暖负荷减少",{"key":24,"text":278,"correct":22},"夏季供冷负荷减少",{"key":28,"text":280,"correct":22},"冬季供暖负荷增加",{"key":31,"text":282,"correct":26},"夏季供冷负荷增加","BC",{"id":285,"libraryId":5,"type":76,"typeLabel":77,"stem":286,"options":287,"answer":31,"analysis":34},880622,"制冷剂的GWP值是制冷剂安全、环境特性的指标之一，GWP的正确描述为下列哪一项？",[288,290,292,294],{"key":20,"text":289,"correct":26},"GWP的大小表示制冷剂对大气臭氧层破坏的大小",{"key":24,"text":291,"correct":26},"GWP的大小表示制冷剂毒性的大小",{"key":28,"text":293,"correct":26},"GWP的大小表示制冷剂在大气中存留时间的长短",{"key":31,"text":295,"correct":22},"GWP的大小表示制冷剂对全球气候变暖程度影响的大小",{"id":297,"libraryId":5,"type":76,"typeLabel":77,"stem":298,"options":299,"answer":24,"analysis":34},880623,"关于单跨热车间自然通风进、排风窗(局部阻力系数相等)面积与中和界位置，下列哪一项正确？( )",[300,302,304,306],{"key":20,"text":301,"correct":26},"进风窗面积越大，中和界越靠近排风口",{"key":24,"text":303,"correct":22},"进风窗面积越大，中和界越靠近进风口",{"key":28,"text":305,"correct":26},"排风口面积越大，中和界越靠近进风口",{"key":31,"text":307,"correct":26},"进、排风口增加同样的面积，中和界位置不变",{"id":309,"libraryId":5,"type":76,"typeLabel":77,"stem":310,"options":311,"answer":24,"analysis":34},880624,"垂直双管式散热器热水供暖系统连接散热器的支管设计，以下哪种方法有利于水力平衡？( )",[312,314,316,318],{"key":20,"text":313,"correct":26},"选择较小的管径，配置低阻调节阀",{"key":24,"text":315,"correct":22},"选择较小的管径，配置高阻调节阀",{"key":28,"text":317,"correct":26},"选择较大的管径，配置高阻调节阀",{"key":31,"text":319,"correct":26},"选择较大的管径，配置低阻调节阀",{"id":321,"libraryId":5,"type":76,"typeLabel":77,"stem":322,"options":323,"answer":20,"analysis":34},880625,"果蔬的呼吸热与( )有关。",[324,326,328,330],{"key":20,"text":325,"correct":22},"贮藏温度",{"key":24,"text":327,"correct":26},"含水量",{"key":28,"text":329,"correct":26},"密度",{"key":31,"text":331,"correct":26},"导热系数",{"id":333,"libraryId":5,"type":76,"typeLabel":77,"stem":334,"options":335,"answer":20,"analysis":34},880626,"冷却塔的性能与( )关系很密切。",[336,338,340,342],{"key":20,"text":337,"correct":22},"空气湿球温度，冷却水的进、出口温度",{"key":24,"text":339,"correct":26},"空气干球温度，冷却水的进、出口温度",{"key":28,"text":341,"correct":26},"空气湿球温度，压缩机的蒸发温度",{"key":31,"text":343,"correct":26},"空气干球温度，压缩机的蒸发温度",{"id":345,"libraryId":5,"type":76,"typeLabel":77,"stem":346,"options":347,"answer":20,"analysis":34},880627,"全面通风又称为( )。",[348,350,352,354],{"key":20,"text":349,"correct":22},"稀释通风",{"key":24,"text":351,"correct":26},"诱导通风",{"key":28,"text":353,"correct":26},"置换通风",{"key":31,"text":355,"correct":26},"自然通风和局部通风",{"id":357,"libraryId":5,"type":76,"typeLabel":77,"stem":358,"options":359,"answer":20,"analysis":34},880628,"锅炉房燃油系统的设计，下列说法正确的是( )。",[360,362,364,366],{"key":20,"text":361,"correct":22},"室内油箱应采用闭式油箱",{"key":24,"text":363,"correct":26},"贮油罐的总容量为10天的锅炉房最大计算耗油量",{"key":28,"text":365,"correct":26},"输油泵的容量不应小于锅炉房小时最大计算耗油量的120%",{"key":31,"text":34,"correct":26},{"id":368,"libraryId":5,"type":76,"typeLabel":77,"stem":369,"options":370,"answer":24,"analysis":34},880629,"当静电除尘器进口含浓度高时，会产生下列哪一种现象？",[371,373,375,377],{"key":20,"text":372,"correct":26},"反电晕放电",{"key":24,"text":374,"correct":22},"电晕闭塞",{"key":28,"text":376,"correct":26},"扩散荷电速度大于碰撞荷电速度",{"key":31,"text":378,"correct":26},"二次飞扬现象加剧，使除尘效率下降",{"id":380,"libraryId":5,"type":76,"typeLabel":77,"stem":381,"options":382,"answer":20,"analysis":34},880630,"当各房间的热湿负荷变化情况相似，采用集中控制各房间的温湿度波动在允许范围之内时，宜采用( )系统。",[383,385,387,389],{"key":20,"text":384,"correct":22},"全空气定风量",{"key":24,"text":386,"correct":26},"风机盘管",{"key":28,"text":388,"correct":26},"全空气变风量",{"key":31,"text":390,"correct":26},"局部空调机组",{"id":392,"libraryId":5,"type":76,"typeLabel":77,"stem":393,"options":394,"answer":28,"analysis":34},880631,"采用直燃型溴化锂吸收式冷(温)水机组，下列说法正确的是( )。",[395,397,399,401],{"key":20,"text":396,"correct":26},"为保证安全，机房不能设在建筑物地下层",{"key":24,"text":398,"correct":26},"因轻柴油不需要加热输送，加热热源应优先选用轻柴油",{"key":28,"text":400,"correct":22},"应按冷负荷选型",{"key":31,"text":402,"correct":26},"当热负荷大于机组供热量时，应加大机型以增加供热量",{"id":404,"libraryId":5,"type":76,"typeLabel":77,"stem":405,"options":406,"answer":31,"analysis":34},880632,"毛细管网辐射供暖系统供水温度的选取，下列哪个说法是正确的？( )",[407,409,411,413],{"key":20,"text":408,"correct":26},"宜采用25～35℃",{"key":24,"text":410,"correct":26},"应采用35～45℃",{"key":28,"text":412,"correct":26},"宜采用30～40℃",{"key":31,"text":414,"correct":22},"与毛细管网设置位置有关",{"id":416,"libraryId":5,"type":76,"typeLabel":77,"stem":417,"options":418,"answer":31,"analysis":34},880633,"单管异程式热水供暖系统立管的压力损失与计算环路总压力损失的比值不宜小于下列哪个值？( )",[419,421,423,425],{"key":20,"text":420,"correct":26},"10%",{"key":24,"text":422,"correct":26},"15%",{"key":28,"text":424,"correct":26},"50%",{"key":31,"text":426,"correct":22},"70%",{"id":428,"libraryId":5,"type":76,"typeLabel":77,"stem":429,"options":430,"answer":20,"analysis":34},880634,"某高层建筑的封闭避难层需设置加压送风系统，避难层的净面积为800㎡，设计的加压送风量下列哪一项不符合要求？( )",[431,432,433,434],{"key":20,"text":34,"correct":22},{"key":24,"text":34,"correct":26},{"key":28,"text":34,"correct":26},{"key":31,"text":34,"correct":26},{"id":436,"libraryId":5,"type":76,"typeLabel":77,"stem":437,"options":438,"answer":28,"analysis":34},880635,"现场组装的除尘器壳体应做漏风量检测，在设计工作压力下离心式除尘器允许的最大漏风率，应为下列哪一项？",[439,441,443,445],{"key":20,"text":440,"correct":26},"5%",{"key":24,"text":442,"correct":26},"4%",{"key":28,"text":444,"correct":22},"3%",{"key":31,"text":446,"correct":26},"2%",{"id":448,"libraryId":5,"type":76,"typeLabel":77,"stem":449,"options":450,"answer":24,"analysis":34},880636,"采用集中热风供暖时，送风温度不得高于( )。",[451,453,455,457],{"key":20,"text":452,"correct":26},"60℃",{"key":24,"text":454,"correct":22},"70℃",{"key":28,"text":456,"correct":26},"室内设计温度10℃",{"key":31,"text":458,"correct":26},"根据送风口高度确定",{"id":460,"libraryId":5,"type":76,"typeLabel":77,"stem":461,"options":462,"answer":31,"analysis":34},880637,"要求设置在建筑物内首层的燃气锅炉房事故排风时换气次数不应小于( )。",[463,464,465,466],{"key":20,"text":34,"correct":26},{"key":24,"text":34,"correct":26},{"key":28,"text":34,"correct":26},{"key":31,"text":34,"correct":22},{"id":468,"libraryId":5,"type":76,"typeLabel":77,"stem":469,"options":470,"answer":31,"analysis":34},880638,"按照《公建节能》，在舒适性空调建筑的热工设计时，可以不考虑的因素是( )。",[471,473,475,477],{"key":20,"text":472,"correct":26},"当地气象条件",{"key":24,"text":474,"correct":26},"建筑窗墙面积比",{"key":28,"text":476,"correct":26},"建筑体形系数",{"key":31,"text":478,"correct":22},"空调室内设计参数",{"id":480,"libraryId":5,"type":76,"typeLabel":77,"stem":481,"options":482,"answer":20,"analysis":34},880639,"高温型活塞式压缩机的压缩比不能大于( )。",[483,485,487,489],{"key":20,"text":484,"correct":22},"6",{"key":24,"text":486,"correct":26},"10",{"key":28,"text":488,"correct":26},"12",{"key":31,"text":490,"correct":26},"16",{"id":492,"libraryId":5,"type":76,"typeLabel":77,"stem":493,"options":494,"answer":28,"analysis":34},880640,"丁类厂房中任一层建筑面积大于( )时应设置排烟设施。",[495,497,499,501],{"key":20,"text":496,"correct":26},"3000㎡",{"key":24,"text":498,"correct":26},"4000㎡",{"key":28,"text":500,"correct":22},"5000㎡",{"key":31,"text":502,"correct":26},"6000㎡",{"id":504,"libraryId":5,"type":76,"typeLabel":77,"stem":505,"options":506,"answer":24,"analysis":34},880641,"某六层住宅建筑，设计热水集中采暖系统时，正确的做法是下列哪一项？",[507,509,511,513],{"key":20,"text":508,"correct":26},"采暖系统的总热负荷应计入向邻户传热引起的耗热量附加",{"key":24,"text":510,"correct":22},"计算户内管道时，应计入向邻户传热引起的耗热量附加",{"key":28,"text":512,"correct":26},"户用热量表的流量传感器应安装在回水管上，热量表前应设置过滤器",{"key":31,"text":514,"correct":26},"户内系统应为垂直单管串联式系统，热力入口设置流量调节阀",{"id":516,"libraryId":5,"type":76,"typeLabel":77,"stem":517,"options":518,"answer":31,"analysis":34},880642,"构成围护结构热惰性指标的参数中，不包括下列哪一个参数？( )",[519,520,522,524],{"key":20,"text":331,"correct":26},{"key":24,"text":521,"correct":26},"围护结构厚度",{"key":28,"text":523,"correct":26},"材料蓄热系数",{"key":31,"text":525,"correct":22},"内外表面换热系数",{"id":527,"libraryId":5,"type":76,"typeLabel":77,"stem":528,"options":529,"answer":20,"analysis":34},880643,"饱和温度140℃的高压蒸汽用作暖风机的热媒，其疏水器的设计排水量应大于理论排水量的倍率宜取( )。",[530,532,534,536],{"key":20,"text":531,"correct":22},"2",{"key":24,"text":533,"correct":26},"2～3",{"key":28,"text":535,"correct":26},"3",{"key":31,"text":537,"correct":26},"4",{"id":539,"libraryId":5,"type":76,"typeLabel":77,"stem":540,"options":541,"answer":20,"analysis":34},880644,"选择余热利用设备时，当电负荷与冷负荷不同步时，或发电余热不能满足用户设计冷、热负荷时，宜选用( )。",[542,544,546,548],{"key":20,"text":543,"correct":22},"余热补燃型",{"key":24,"text":545,"correct":26},"余热型+直燃型",{"key":28,"text":547,"correct":26},"余热型",{"key":31,"text":549,"correct":26},"以上均可",{"id":551,"libraryId":5,"type":76,"typeLabel":77,"stem":552,"options":553,"answer":24,"analysis":34},880645,"采用吸附法去除有害气体，错误的选择应是下列哪一项？( )",[554,555,557,558],{"key":20,"text":34,"correct":26},{"key":24,"text":556,"correct":22},"用活性炭吸附苯、沥青烟",{"key":28,"text":34,"correct":26},{"key":31,"text":34,"correct":26},{"id":560,"libraryId":5,"type":76,"typeLabel":77,"stem":561,"options":562,"answer":24,"analysis":34},880646,"某办公建筑(吊顶高3.6m)设计空调系统时，于吊顶上布置送风口，合理的设计选项应是下列哪一项？( )",[563,565,567,569],{"key":20,"text":564,"correct":26},"采用方形散流器送风口，送风温差为15℃",{"key":24,"text":566,"correct":22},"采用方形散流器送风口，送风温差为10℃",{"key":28,"text":568,"correct":26},"采用旋流送风口，送风温差为15℃",{"key":31,"text":570,"correct":26},"采用旋流送风口，送风温差为10℃",{"id":572,"libraryId":5,"type":76,"typeLabel":77,"stem":573,"options":574,"answer":24,"analysis":34},880647,"采用内表面光滑的非金属风管进行机械排烟时，现行国家标准规定的最高排烟风速为下列哪一项？( )",[575,577,579,581],{"key":20,"text":576,"correct":26},"10m\u002Fs",{"key":24,"text":578,"correct":22},"15m\u002Fs",{"key":28,"text":580,"correct":26},"18m\u002Fs",{"key":31,"text":582,"correct":26},"20m\u002Fs",{"id":584,"libraryId":5,"type":76,"typeLabel":77,"stem":585,"options":586,"answer":24,"analysis":34},880648,"油库火灾属于( )。",[587,589,591,593],{"key":20,"text":588,"correct":26},"A类火灾",{"key":24,"text":590,"correct":22},"B类火灾",{"key":28,"text":592,"correct":26},"C类火灾",{"key":31,"text":594,"correct":26},"D类火灾",{"id":596,"libraryId":5,"type":76,"typeLabel":77,"stem":597,"options":598,"answer":31,"analysis":34},880649,"民用建筑供暖系统适宜采用下列哪种热媒？( )",[599,601,603,605],{"key":20,"text":600,"correct":26},"低压蒸汽",{"key":24,"text":602,"correct":26},"高压蒸汽",{"key":28,"text":604,"correct":26},"温度不超超过100℃的热水",{"key":31,"text":606,"correct":22},"温度不超过85℃的热水",{"id":608,"libraryId":5,"type":76,"typeLabel":77,"stem":609,"options":610,"answer":24,"analysis":34},880650,"燃气热值大小排序为( )。",[611,613,615,617],{"key":20,"text":612,"correct":26},"人工燃气热值＞天然气热值＞液化石油气热值",{"key":24,"text":614,"correct":22},"人工燃气热值＜天然气热值＜液化石油气热值",{"key":28,"text":616,"correct":26},"天然气热值＜人工燃气热值＜液化石油气热值",{"key":31,"text":618,"correct":26},"液化石油气热值＜人工燃气热值＜天然气热值",[620,623,626,629,632,635],{"id":76,"name":621,"category":7,"favorite":622},"领导干部任职前廉政法规知识测试题",92,{"id":624,"name":625,"category":7,"favorite":76},595,"建筑结构与设备",{"id":627,"name":628,"category":7,"favorite":76},715,"招标采购专业知识与法律法规",{"id":630,"name":631,"category":7,"favorite":76},848,"市政方向-通用基础",{"id":633,"name":634,"category":7,"favorite":8},534,"BIM工程师",{"id":636,"name":634,"category":7,"favorite":8},535]