[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-15":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":618},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,15,50,2054,[13,35,48,62,74,86,98,110,118,131,144,156,168,176,189,201,213,225,237,249,261,273,286,298,310,322,334,346,358,371,383,395,407,419,431,443,456,468,480,492,503,514,526,538,550,562,574,586,598,606],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},880551,2,"多选题","关于组合式空调机组的设计原则，错误的有( )。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","组合式空调机组的制冷量和制热量应按产品样本中的额定值选取",true,{"key":24,"text":25,"correct":22},"B","高压喷雾加湿器出口紧接着设置过滤器",{"key":27,"text":28,"correct":29},"C","对于温度控制精度要求较高的工艺性空调，空气加热器应设置在表冷器的出口",false,{"key":31,"text":32,"correct":22},"D","消声器应尽量由组合式空调机组配带，避免在风管上设置消声器","ABD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},880552,"关于中国标准规定的D类高效过滤器，下列哪些是错误的？",[39,41,43,45],{"key":20,"text":40,"correct":22},"规定无隔板高效过滤器的额定风量对应的面风速为0.45～0.75m\u002Fs",{"key":24,"text":42,"correct":29},"按规定产品出厂前应检漏",{"key":27,"text":44,"correct":29},"对粒径大于等于O.lμm微粒的计数透过率不高于0.001%",{"key":31,"text":46,"correct":22},"过滤器全部材料应是不燃或难燃性的","AD",{"id":49,"libraryId":5,"type":50,"typeLabel":51,"stem":52,"options":53,"answer":31,"analysis":34},880553,1,"单选题","水泵的电动机(联轴器连接)实际运行耗用功率过大，导致能源浪费加剧，引起问题发生的原因，下列哪项是错误的？",[54,56,58,60],{"key":20,"text":55,"correct":29},"电动机转速过高",{"key":24,"text":57,"correct":29},"水泵的填料压得过紧",{"key":27,"text":59,"correct":29},"水泵叶轮与蜗壳发生摩擦",{"key":31,"text":61,"correct":22},"水泵与电动机的轴处于同心",{"id":63,"libraryId":5,"type":50,"typeLabel":51,"stem":64,"options":65,"answer":27,"analysis":34},880554,"全面通风效果取决于( )。",[66,68,70,72],{"key":20,"text":67,"correct":29},"通风量",{"key":24,"text":69,"correct":29},"气流组织",{"key":27,"text":71,"correct":22},"通风量和气流组织",{"key":31,"text":73,"correct":29},"换气次数",{"id":75,"libraryId":5,"type":50,"typeLabel":51,"stem":76,"options":77,"answer":24,"analysis":34},880555,"由于风的作用，在建筑物表面所形成的空气( )变化称为风压。",[78,80,82,84],{"key":20,"text":79,"correct":29},"动压",{"key":24,"text":81,"correct":22},"静压",{"key":27,"text":83,"correct":29},"全压",{"key":31,"text":85,"correct":29},"不同情况不同",{"id":87,"libraryId":5,"type":50,"typeLabel":51,"stem":88,"options":89,"answer":24,"analysis":34},880556,"影响围护结构热稳定性的最主要因素是下列哪一项？",[90,92,94,96],{"key":20,"text":91,"correct":29},"传热系数",{"key":24,"text":93,"correct":22},"热惰性指标",{"key":27,"text":95,"correct":29},"衰减倍数",{"key":31,"text":97,"correct":29},"延迟时间",{"id":99,"libraryId":5,"type":50,"typeLabel":51,"stem":100,"options":101,"answer":31,"analysis":34},880557,"下面几组空气状态参数中，在焓湿图不能唯一地确定状态点的是( )。",[102,104,106,108],{"key":20,"text":103,"correct":29},"干球温度和相对湿度",{"key":24,"text":105,"correct":29},"湿球温度和相对湿度",{"key":27,"text":107,"correct":29},"干球温度和露点温度",{"key":31,"text":109,"correct":22},"比焓和湿球温度",{"id":111,"libraryId":5,"type":50,"typeLabel":51,"stem":112,"options":113,"answer":24,"analysis":34},880558,"要求设置在建筑物内首层的燃油锅炉房事故排风时换气次数不应小于( )。",[114,115,116,117],{"key":20,"text":34,"correct":29},{"key":24,"text":34,"correct":22},{"key":27,"text":34,"correct":29},{"key":31,"text":34,"correct":29},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":130,"analysis":34},880559,"冬季建筑物外墙内表面温度的最低限值与下列哪些因素有关？( )",[122,124,126,128],{"key":20,"text":123,"correct":29},"室外空气温度",{"key":24,"text":125,"correct":22},"室内空气温度",{"key":27,"text":127,"correct":22},"室内空气露点温度",{"key":31,"text":129,"correct":22},"室内空气温度与内表面温度的允许温差","BCD",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":143,"analysis":34},880560,"采暖系统的阀门强度和严密性试验，正确的做法应是下列选项中的哪几项？",[135,137,139,141],{"key":20,"text":136,"correct":29},"安装在主干管上的阀门，应逐个进行试验",{"key":24,"text":138,"correct":29},"阀门的强度试验压力为公称压力的1.2倍",{"key":27,"text":140,"correct":22},"阀门的严密性试验压力为公称压力的1.1倍",{"key":31,"text":142,"correct":22},"最短试验持续时间，随阀门公称直径的增大而延长","CD",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":33,"analysis":34},880561,"进行建筑物围护结构热工设计时，做法正确的是( )。",[148,150,152,154],{"key":20,"text":149,"correct":22},"沈阳某办公楼体形系数为0.3，外墙传热系数为0.4W\u002F(㎡·K)",{"key":24,"text":151,"correct":22},"兰州某办公楼体形系数为0.5，进行权衡判断",{"key":27,"text":153,"correct":29},"南京某写字楼体形系数为0.45，进行权衡判断",{"key":31,"text":155,"correct":22},"福州某写字楼窗墙面积比为0.8，进行权衡判断",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":167,"analysis":34},880562,"关于人民防空地下室通风与空调的设计，正确的是( )。",[160,162,164,166],{"key":20,"text":161,"correct":22},"室外空气计算参数应按照《民用暖规》中有关条文执行",{"key":24,"text":163,"correct":29},"与上部建筑的通风与空调系统最好分开设置",{"key":27,"text":165,"correct":22},"战时物资库是否设置滤毒通风可根据实际情况确定",{"key":31,"text":34,"correct":22},"ACD",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":130,"analysis":34},880563,"某装配车间有28名工人同时工作，设有全面机械通风系统，以保证工人对新风量的需求。试问，该车间符合卫生设计标准的全面换气量的合理数值可选下列哪几个？( )",[172,173,174,175],{"key":20,"text":34,"correct":29},{"key":24,"text":34,"correct":22},{"key":27,"text":34,"correct":22},{"key":31,"text":34,"correct":22},{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":188,"analysis":34},880564,"冷却塔采用生活饮用水系统和中水系统双水源补水时，以下哪些连接方式是错误的？( )",[180,182,184,186],{"key":20,"text":181,"correct":22},"两种管道连接处，在城市给水管道上设置倒流防止器",{"key":24,"text":183,"correct":22},"两种管道连接处，均设置倒流防止器",{"key":27,"text":185,"correct":22},"严禁双水源补水",{"key":31,"text":187,"correct":29},"两种管道分别接人冷却塔底盘水池，进水管口的最低点高出水池溢流边缘不小于进水管口径的2.5倍","ABC",{"id":190,"libraryId":5,"type":50,"typeLabel":51,"stem":191,"options":192,"answer":31,"analysis":34},880565,"计算低温热水地面辐射采暖的热负荷时，下列哪一项是错误的？",[193,195,197,199],{"key":20,"text":194,"correct":29},"比对流采暖系统的室内计算温度低2℃",{"key":24,"text":196,"correct":29},"对寒冷地区，取对流采暖系统计算总负荷的0.9",{"key":27,"text":198,"correct":29},"可以不考虑高度附加",{"key":31,"text":200,"correct":22},"局部地区辐射采暖的面积为房间总面积的70%，则需要计入附加系数",{"id":202,"libraryId":5,"type":50,"typeLabel":51,"stem":203,"options":204,"answer":24,"analysis":34},880566,"关于空调水系统的形式，正确的表述是( )。①同程系统中水流经各用户回路的管路长度相等(接近)②同程式管路的特点是各回路长度相近，阻力容易平衡，耗管材少③异程系统是指系统水流经每一用户回路的管路长度不相等④在实际工程中，应优先考虑设计异程系统⑤设计异程系统时，工程中各并联回路间的阻力差宜控制在15%以内",[205,207,209,211],{"key":20,"text":206,"correct":29},"②④",{"key":24,"text":208,"correct":22},"①③⑤",{"key":27,"text":210,"correct":29},"①②③④",{"key":31,"text":212,"correct":29},"①②③④⑤",{"id":214,"libraryId":5,"type":50,"typeLabel":51,"stem":215,"options":216,"answer":24,"analysis":34},880567,"采用集中热风送暖时，送风温度宜采用30～50℃，但不得高于( )℃。",[217,219,221,223],{"key":20,"text":218,"correct":29},"60",{"key":24,"text":220,"correct":22},"70",{"key":27,"text":222,"correct":29},"80",{"key":31,"text":224,"correct":29},"90",{"id":226,"libraryId":5,"type":50,"typeLabel":51,"stem":227,"options":228,"answer":27,"analysis":34},880568,"设计采暖系统时，下列说法错误的是( )。",[229,231,233,235],{"key":20,"text":230,"correct":29},"热水系统水质的溶解氧应小于或等于0.1mg\u002FL",{"key":24,"text":232,"correct":29},"蒸汽采暖系统中不得采用钢制散热器",{"key":27,"text":234,"correct":22},"在同一采暖系统中，钢制散热器和铝质散热器可同时使用",{"key":31,"text":236,"correct":29},"热水管道内流速不小于0.25m／s时，可无坡设置",{"id":238,"libraryId":5,"type":50,"typeLabel":51,"stem":239,"options":240,"answer":31,"analysis":34},880569,"某严寒地区城市集中采暖，以热电厂作为冬季采暖基本热负荷，区域锅炉房作为调峰采暖，热电厂采用热能利用效率最高的汽轮机应是下列哪一项？",[241,243,245,247],{"key":20,"text":242,"correct":29},"凝汽式汽轮机改装为供热汽轮机",{"key":24,"text":244,"correct":29},"单抽汽式供热汽轮机",{"key":27,"text":246,"correct":29},"双抽式供热汽轮机",{"key":31,"text":248,"correct":22},"背压式供热汽轮机",{"id":250,"libraryId":5,"type":50,"typeLabel":51,"stem":251,"options":252,"answer":31,"analysis":34},880570,"关于热泵机组，下列表述正确的是哪一项？",[253,255,257,259],{"key":20,"text":254,"correct":29},"国家标准《冷水机组能效限定值及能源效率等级》GB19577-2004的相关规定只适合冷水机组，不适合热泵机组",{"key":24,"text":256,"correct":29},"用于评价热泵机组制冷性能的名义工况与冷水机组的名义工况不同",{"key":27,"text":258,"correct":29},"水源热泵机组名义工况时的蒸发器、冷凝器水侧污垢系数均为0.08㎡·℃\u002FkW",{"key":31,"text":260,"correct":22},"具有两个以上独立制冷循环的风冷热泵机组，各独立循环融霜时间的总和不应超过各独立循环总运转时间的20%",{"id":262,"libraryId":5,"type":50,"typeLabel":51,"stem":263,"options":264,"answer":31,"analysis":34},880571,"工艺性空调房间，当室温允许波动值为±0.5℃时，其围护结构的热工参数应选( )。",[265,267,269,271],{"key":20,"text":266,"correct":29},"外墙传热系数K值为1.0W／(㎡？K)，热惰性指标D值为4；顶棚传热系数K值为0.8W／(㎡？K)，热惰性指标D值为4",{"key":24,"text":268,"correct":29},"外墙传热系数K值为0.7W／(㎡？K)，热惰性指标D值为5；顶棚传热系数K值为0.7W／(㎡？K)，热惰性指标D值为4",{"key":27,"text":270,"correct":29},"外墙传热系数K值为0.7W／(㎡？K)，热惰性指标D值为3；顶棚传热系数K值为0.8W／(㎡？K)，热惰性指标D值为4",{"key":31,"text":272,"correct":22},"外墙传热系数K值为0.8W／(㎡？K)，热惰性指标D值为3；顶棚传热系数K值为0.8W／(㎡？K)，热惰性指标D值为3",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":285,"analysis":34},880572,"公共建筑暖通专业施工图的设备表中，需注明所选用风机性能参数的应是下列哪几项？( )",[277,279,281,283],{"key":20,"text":278,"correct":22},"风机全压",{"key":24,"text":280,"correct":22},"风机最低总效率",{"key":27,"text":282,"correct":22},"风机风量",{"key":31,"text":284,"correct":22},"风机的配套电动机功率","ABCD",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":188,"analysis":34},880573,"关于室外空气温度的选择，下列说法正确的是哪几项?( )。",[290,292,294,296],{"key":20,"text":291,"correct":22},"冬季使用的局部送风的室外进风温度采用采暖室外计算温度",{"key":24,"text":293,"correct":22},"夏季使用的局部送风的室外进风温度采用通风室外计算温度",{"key":27,"text":295,"correct":22},"夏季使用的消除有害物质的全面通风的室外进风温度采用通风室外计算温度",{"key":31,"text":297,"correct":29},"冬季使用的消除有害气体的全面通风的室外进风温度采用通风室外计算温度",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":47,"analysis":34},880574,"水环热泵空调系统比较适用于下列哪种场所？( )",[302,304,306,308],{"key":20,"text":303,"correct":22},"北方供暖区、内区较大且常年有稳定的一定量余热的建筑",{"key":24,"text":305,"correct":29},"夏热冬暖地区、有低温余热可利用的场所",{"key":27,"text":307,"correct":29},"有太阳能辅助热源的场所",{"key":31,"text":309,"correct":22},"需要同时供冷和供热的建筑",{"id":311,"libraryId":5,"type":50,"typeLabel":51,"stem":312,"options":313,"answer":31,"analysis":34},880575,"以下变风量空调系统主要节能机理的描述中，哪一项是正确的？",[314,316,318,320],{"key":20,"text":315,"correct":29},"房间负荷变小后，房间需冷量减小，只有采用变风量系统才能够节省冷源设备的能耗",{"key":24,"text":317,"correct":29},"房间负荷变小后，需要冷水流量减小，因此采用变风量系统能够节省水泵的能耗",{"key":27,"text":319,"correct":29},"房间负荷变小后，送风温度可提高，因此采用变风量系统能够节省空气处理的能耗",{"key":31,"text":321,"correct":22},"房间负荷变小后，送风量可降低，因此采用变风量系统能够节省空气输送的能耗",{"id":323,"libraryId":5,"type":50,"typeLabel":51,"stem":324,"options":325,"answer":27,"analysis":34},880576,"供暖设计热负荷附加耗热量的确定，下列哪一项是错误的？( )",[326,328,330,332],{"key":20,"text":327,"correct":29},"阳台门不考虑外门附加",{"key":24,"text":329,"correct":29},"公共建筑房间若有两面外墙，则外墙、窗、门的基本耗热量增加5%",{"key":27,"text":331,"correct":22},"窗墙面积10%过0.5时，对窗的基本耗热量附加10%",{"key":31,"text":333,"correct":29},"仅白天供暖的办公楼应对围护结构基本耗热量进行20%的间歇附加",{"id":335,"libraryId":5,"type":50,"typeLabel":51,"stem":336,"options":337,"answer":20,"analysis":34},880577,"螺杆式压缩机的容积效率较高，是因为( )。",[338,340,342,344],{"key":20,"text":339,"correct":22},"气缸内无余隙容积和吸、排气阀片",{"key":24,"text":341,"correct":29},"转速较高",{"key":27,"text":343,"correct":29},"压缩机的压缩腔内喷油，起到良好的密封、润滑和冷却作用",{"key":31,"text":345,"correct":29},"气缸的适当位置开设补气口，与经济器连接，组成带经济器的制冷循环",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":33,"analysis":34},880578,"建筑高度为70m的高层塔式住宅，其剪刀楼梯间每层各有可开启外窗面积1.㎡，但需要共用同一个防烟楼梯间前室，下列哪些防排烟设计做法是错误的？( )",[350,352,354,356],{"key":20,"text":351,"correct":22},"如果前室也具有自然排烟条件，楼梯间和前室都可以采用自然排烟",{"key":24,"text":353,"correct":22},"如果前室不具有自然排烟条件，对前室和两个楼梯间分别设置加压送风系统",{"key":27,"text":355,"correct":29},"如果前室不具有自然排烟条件，仅对两个楼梯间分别设置加压送风系统",{"key":31,"text":357,"correct":22},"如果前室不具有自然排烟条件，仅对前室加压送风",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":370,"analysis":34},880579,"风机盘管额定风量和额定供冷量的说法中，正确的是( )。",[362,364,366,368],{"key":20,"text":363,"correct":22},"额定风量是高速挡的风量",{"key":24,"text":365,"correct":29},"额定风量是中速挡的风量",{"key":27,"text":367,"correct":22},"额定供冷量是高速挡的供冷量",{"key":31,"text":369,"correct":29},"额定供冷量是中速挡的供冷量","AC",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":188,"analysis":34},880580,"下列关于氨的性质，说法正确的是( )。",[375,377,379,381],{"key":20,"text":376,"correct":22},"氨是应用较广的中温制冷剂，标准沸点为-33.3℃，凝固点为-77.9℃",{"key":24,"text":378,"correct":22},"氨单位容积制冷量大，黏性小，流动阻力小，比热容大，传热性能好",{"key":27,"text":380,"correct":22},"车间内的工作区里，氨蒸气的含量不得超过0.22mg\u002FL",{"key":31,"text":382,"correct":29},"由于氨中的含水量不得超过0.2%，因此氨系统里一般设置干燥器",{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":143,"analysis":34},880581,"在下列哪几种情况下，制冷压缩机的性能系数会下降？( )",[387,389,391,393],{"key":20,"text":388,"correct":29},"蒸发温度一定而冷凝温度下降",{"key":24,"text":390,"correct":29},"冷凝温度一定而蒸发温度上升",{"key":27,"text":392,"correct":22},"蒸发温度一定而冷凝温度上升",{"key":31,"text":394,"correct":22},"冷凝温度一定而蒸发温度下降",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":188,"analysis":34},880582,"下列关于冷水机组的说法，正确的是( )。",[399,401,403,405],{"key":20,"text":400,"correct":22},"常见的有活塞式、螺杆式和离心式冷水机组",{"key":24,"text":402,"correct":22},"离心式冷水机组适用于制冷量较大的场合",{"key":27,"text":404,"correct":22},"活塞式冷水机组适用于中、小制冷量场合",{"key":31,"text":406,"correct":29},"离心式冷水机组适用于中、小制冷量场合",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":285,"analysis":34},880583,"关于空气过滤器的容尘量，下列正确的说法是( )。",[411,413,415,417],{"key":20,"text":412,"correct":22},"当过滤器的沾尘量超过容尘量后，过滤器阻力会变大，过滤效率会下降",{"key":24,"text":414,"correct":22},"空气过滤器的容尘量表示了过滤器容纳尘埃量的能力",{"key":27,"text":416,"correct":22},"要测定容尘量，首先要确定其试验尘和使用期限",{"key":31,"text":418,"correct":22},"容尘量与其所处理的气溶胶的分散度(或微粒群的粒径分布)有关联",{"id":420,"libraryId":5,"type":50,"typeLabel":51,"stem":421,"options":422,"answer":20,"analysis":34},880584,"以下有关袋式除尘器性能的描述，哪一项是错误的？",[423,425,427,429],{"key":20,"text":424,"correct":22},"袋式除尘器的阻力和进口空气的密度成正比",{"key":24,"text":426,"correct":29},"袋式除尘器过滤层的阻力与过滤风速成正比",{"key":27,"text":428,"correct":29},"对于1弘m以上的粉尘，袋式除尘器的除尘效率一般可达到99.5%",{"key":31,"text":430,"correct":29},"袋式除尘器的漏风率小于5%，表明产品该项性能合格",{"id":432,"libraryId":5,"type":50,"typeLabel":51,"stem":433,"options":434,"answer":31,"analysis":34},880585,"为增大散热器的有效散热量，下列措施哪一项是错误的？( )",[435,437,439,441],{"key":20,"text":436,"correct":29},"散热器外表面涂瓷漆",{"key":24,"text":438,"correct":29},"散热器背面外墙部位增加保温层",{"key":27,"text":440,"correct":29},"散热器背面外墙部位贴铝箔",{"key":31,"text":442,"correct":22},"散热器装在罩内",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":455,"analysis":34},880586,"下列属于近共沸混合制冷剂的是( )。",[447,449,451,453],{"key":20,"text":448,"correct":22},"R404A",{"key":24,"text":450,"correct":22},"R410A",{"key":27,"text":452,"correct":29},"R507A",{"key":31,"text":454,"correct":29},"R407C","AB",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":47,"analysis":34},880587,"在地埋管地源热泵空调系统设计时，地埋管换热器的长度算法中正确的是( )。",[460,462,464,466],{"key":20,"text":461,"correct":22},"应分别按供冷和供热工况进行计算",{"key":24,"text":463,"correct":29},"取其计算长度的最大值作为地埋管的长度",{"key":27,"text":465,"correct":29},"取其计算长度的平均值作为地埋管的长度",{"key":31,"text":467,"correct":22},"当地埋管系统的最大释热量和最大吸热量相差较大时，宜取其计算长度的最小值作为地埋管的长度",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":143,"analysis":34},880588,"关于蒸汽压缩式制冷设备的表述，下列哪几项是正确的？",[472,474,476,478],{"key":20,"text":473,"correct":29},"被处理空气经过蒸发器降温除湿后又被冷凝器加热，则空气温度不变，含湿量降低",{"key":24,"text":475,"correct":29},"活塞式压缩机和涡旋式压缩机的容积效率均受到余隙容积的影响",{"key":27,"text":477,"correct":22},"热泵循环采用蒸汽旁通除霜时，会导致室内供热量不足",{"key":31,"text":479,"correct":22},"微通道换热器可强化制冷剂的冷凝换热效果，减小冷凝器的体积",{"id":481,"libraryId":5,"type":50,"typeLabel":51,"stem":482,"options":483,"answer":31,"analysis":34},880589,"关于通风系统的设计，下列哪一项是错误的？( )",[484,486,488,490],{"key":20,"text":485,"correct":29},"通风机的风量除满足计算风量外，还应附加设备和风管的漏风量",{"key":24,"text":487,"correct":29},"一般送风系统的风管漏风附加率为5%～10%",{"key":27,"text":489,"correct":29},"一般排风系统的风管漏风附加率为5%～10%",{"key":31,"text":491,"correct":22},"管网计算中应考虑管道的漏风量",{"id":493,"libraryId":5,"type":50,"typeLabel":51,"stem":494,"options":495,"answer":31,"analysis":34},880590,"与空调新风量调控相关性最小的参数是( )。",[496,497,499,501],{"key":20,"text":34,"correct":29},{"key":24,"text":498,"correct":29},"室内外比焓差",{"key":27,"text":500,"correct":29},"室外温度",{"key":31,"text":502,"correct":22},"室内温度",{"id":504,"libraryId":5,"type":50,"typeLabel":51,"stem":505,"options":506,"answer":27,"analysis":34},880591,"设计供暖系统时，下列哪一项是错误的？( )",[507,508,510,512],{"key":20,"text":230,"correct":29},{"key":24,"text":509,"correct":29},"蒸汽供暖系统中不应采用钢制散热器",{"key":27,"text":511,"correct":22},"在同一热水系统中，钢制和铝制散热器可同时使用",{"key":31,"text":513,"correct":29},"热水系统管道内水速不小于0.25m\u002Fs时，可无坡度敷设",{"id":515,"libraryId":5,"type":50,"typeLabel":51,"stem":516,"options":517,"answer":20,"analysis":34},880592,"表征某一系统阻抗S值的单位是( )。",[518,520,522,524],{"key":20,"text":519,"correct":22},"阻力\u002F流量的平方",{"key":24,"text":521,"correct":29},"阻力\u002F流量",{"key":27,"text":523,"correct":29},"流量的平方\u002F阻力",{"key":31,"text":525,"correct":29},"流量\u002F阻力",{"id":527,"libraryId":5,"type":50,"typeLabel":51,"stem":528,"options":529,"answer":24,"analysis":34},880593,"大中型和多层冷藏库多采用下列哪一项制冷系统？",[530,532,534,536],{"key":20,"text":531,"correct":29},"盐水供冷系统",{"key":24,"text":533,"correct":22},"液泵供液系统",{"key":27,"text":535,"correct":29},"直接膨胀式供液系统",{"key":31,"text":537,"correct":29},"重力式供液系统",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":455,"analysis":34},880594,"接受式排风罩与外部吸气罩的关键不同点在于( )。",[542,544,546,548],{"key":20,"text":543,"correct":22},"罩口外污染气流流动的动力不同",{"key":24,"text":545,"correct":22},"排风量的计算原理不同",{"key":27,"text":547,"correct":29},"形状不同",{"key":31,"text":549,"correct":29},"距污染源的距离不同",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":188,"analysis":34},880595,"空气的含尘浓度系指单位体积空气中所含的灰尘量，其表示法有( )。",[554,556,558,560],{"key":20,"text":555,"correct":22},"质量浓度",{"key":24,"text":557,"correct":22},"计数浓度",{"key":27,"text":559,"correct":22},"粒径颗粒浓度",{"key":31,"text":561,"correct":29},"粒径分布",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":33,"analysis":34},880596,"关于变制冷剂流量(VRV)空调系统的特点，下列表述中错误的是( )。",[566,568,570,572],{"key":20,"text":567,"correct":22},"VRV热泵式空调系统不能在低于-5℃的低温环境中工作",{"key":24,"text":569,"correct":22},"VRV空调系统可用于产生电磁波和高频波的环境",{"key":27,"text":571,"correct":29},"在VRV空调系统制冷量计算时，应对制冷剂配管长度进行修正",{"key":31,"text":573,"correct":22},"VRV空调系统的室内机连接率可以达到130%，因此它是节能的",{"id":575,"libraryId":5,"type":50,"typeLabel":51,"stem":576,"options":577,"answer":24,"analysis":34},880597,"蒸汽压缩循环(热泵)机组制热名义工况时的参数，下列哪一项不符合国家标准？",[578,580,582,584],{"key":20,"text":579,"correct":29},"使用侧制热，进出口水温度为40\u002F45℃",{"key":24,"text":581,"correct":22},"热源侧水冷式(制热)，进出口水温度为12／7℃",{"key":27,"text":583,"correct":29},"热源侧风冷式(制热)，空气干球温度为7℃",{"key":31,"text":585,"correct":29},"热源侧风冷式(制热)，空气湿球温度为6℃",{"id":587,"libraryId":5,"type":50,"typeLabel":51,"stem":588,"options":589,"answer":20,"analysis":34},880598,"采用大温差冷水时，冰蓄冷系统宜采用( )。",[590,592,594,596],{"key":20,"text":591,"correct":22},"“制冷机上游”串联系统",{"key":24,"text":593,"correct":29},"“制冷机下游”串联系统",{"key":27,"text":595,"correct":29},"并联系统",{"key":31,"text":597,"correct":29},"以上方式没有差别",{"id":599,"libraryId":5,"type":50,"typeLabel":51,"stem":600,"options":601,"answer":27,"analysis":34},880599,"某95℃热水供热系统，下图中哪一种膨胀水箱与系统形式不宜采用？( )",[602,603,604,605],{"key":20,"text":34,"correct":29},{"key":24,"text":34,"correct":29},{"key":27,"text":34,"correct":22},{"key":31,"text":34,"correct":29},{"id":607,"libraryId":5,"type":15,"typeLabel":16,"stem":608,"options":609,"answer":33,"analysis":34},880600,"空调冷负荷的计算，下列哪些说法是正确的？( )",[610,612,614,616],{"key":20,"text":611,"correct":22},"方案设计可使用冷负荷指标估算",{"key":24,"text":613,"correct":22},"初步设计可使用冷负荷估算",{"key":27,"text":615,"correct":29},"施工图设计可使用冷负荷指标估算，但需要考虑同时使用系数",{"key":31,"text":617,"correct":22},"施工图设计应逐项逐时计算",[619,622,625,628,631,634],{"id":50,"name":620,"category":7,"favorite":621},"领导干部任职前廉政法规知识测试题",92,{"id":623,"name":624,"category":7,"favorite":50},595,"建筑结构与设备",{"id":626,"name":627,"category":7,"favorite":50},715,"招标采购专业知识与法律法规",{"id":629,"name":630,"category":7,"favorite":50},848,"市政方向-通用基础",{"id":632,"name":633,"category":7,"favorite":8},534,"BIM工程师",{"id":635,"name":633,"category":7,"favorite":8},535]