[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":624},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,14,50,2054,[13,35,48,61,74,86,99,112,125,137,149,161,174,186,198,211,223,232,244,256,268,280,292,304,316,328,340,347,359,371,384,396,408,420,432,444,456,468,480,492,504,516,525,538,550,562,574,588,600,612],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},880501,2,"多选题","可采用热风采暖的场合是( )。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","能与机械送风系统相合并的场合",true,{"key":24,"text":25,"correct":22},"B","可以利用循环空气的场合",{"key":27,"text":28,"correct":29},"C","空气中含有病原体的车间",false,{"key":31,"text":32,"correct":29},"D","产生粉尘的车间","AB","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},880502,"夏热冬暖地区的居住建筑，当采用“对比评定法”对其节能设计进行综合评价时，“参照建筑”是指( )。",[39,41,43,45],{"key":20,"text":40,"correct":29},"与所设计建筑规模相近和层数相同的其他节能居住建筑",{"key":24,"text":42,"correct":22},"形状、大小、朝向与所设计建筑完全一致的假想建筑",{"key":27,"text":44,"correct":29},"作为比较能耗的基础的20世纪80年代建造的居住建筑",{"key":31,"text":46,"correct":22},"每面外墙均应按比例缩小、每个窗户和屋顶透明部分的面积均应按比例缩小，使建筑的体形系数、窗墙面积比和屋顶透明部分的面积符合本标准的建筑计算模型","BD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},880503,"下列哪几组参数可以在焓湿图上确定空气状态点？( )",[52,54,56,58],{"key":20,"text":53,"correct":22},"含湿量，干球温度",{"key":24,"text":55,"correct":22},"湿球温度，露点温度",{"key":27,"text":57,"correct":29},"含湿量，水蒸气分压力",{"key":31,"text":59,"correct":22},"水蒸气分压力，比焓","ABD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},880504,"下列关于空调冷热源能源的选择原则，错误的表述是( )。",[65,67,69,71],{"key":20,"text":66,"correct":22},"由于电力空调方便、清洁、高效、可靠，因此应尽可能采用电力空调",{"key":24,"text":68,"correct":22},"采用燃气空调可以大幅度减少电耗，因此在电力紧张的地区应大力推广应用",{"key":27,"text":70,"correct":22},"燃煤锅炉污染大，作为空调热源应逐步实现“煤改气”",{"key":31,"text":72,"correct":29},"应考虑当地的具体情况，包括建筑物规模、建筑规划情况等因素，通过综合技术经济性比较来确定","ABC",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":60,"analysis":34},880505,"通风机房布置原则，正确的是( )。",[78,80,82,84],{"key":20,"text":79,"correct":22},"用于甲、乙类场所的通风、空调和热风供暖送风设备不应与排风设备布置在同一通风机房内",{"key":24,"text":81,"correct":22},"用于排除甲、乙类物质的排风设备不应与其他系统的通风设备布置在同一通风机房内",{"key":27,"text":83,"correct":29},"用于甲、乙类场所的送风设备不应与其他系统的送风设备布置在同一通风机房内",{"key":31,"text":85,"correct":22},"甲、乙类厂房的全面和局部送排风设备不应布置在地下室内",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":98,"analysis":34},880506,"下列关于湿空气参数与处理过程的说法，哪几项是错误的？",[90,92,94,96],{"key":20,"text":91,"correct":29},"闭式冷却塔夏季工作时的出风温度一定高于进塔的风温",{"key":24,"text":93,"correct":22},"高温热水对空气进行喷淋处理可以实现任意热湿比线的加热升温过程",{"key":27,"text":95,"correct":22},"游泳池对底部进行加热，则稳定时表面水温应不高于上部空气温度",{"key":31,"text":97,"correct":22},"间接蒸发冷却不仅可以产生低于湿球温度的冷水，也可产生低于湿球温度的风","BCD",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":111,"analysis":34},880507,"下列情况中，适合采用蓄冷空调系统的基本条件是( )。",[103,105,107,109],{"key":20,"text":104,"correct":22},"实行峰谷电价的地区",{"key":24,"text":106,"correct":29},"居住建筑",{"key":27,"text":108,"correct":22},"综合技术经济性比较合理",{"key":31,"text":110,"correct":22},"空调负荷高峰和电网负荷高峰重合，且在用电低谷段空调负荷较小","ACD",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":124,"analysis":34},880508,"地势平坦区域中的高层民用建筑，其制冷设备机房设于地下室时的正确作法，应是下列哪几项？( )",[116,118,120,122],{"key":20,"text":117,"correct":22},"在设计时应考虑设备运输与就位的通道",{"key":24,"text":119,"correct":29},"预留垂直的设备吊装孔",{"key":27,"text":121,"correct":29},"避免设备或材料荷载集中到楼板上",{"key":31,"text":123,"correct":22},"利用梁柱起吊设备时，必须复核梁柱的强度","AD",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":73,"analysis":34},880509,"某居住建筑设置独立的散热器热水采暖系统，采用哪些措施能够实现运行节能？",[129,131,133,135],{"key":20,"text":130,"correct":22},"采用水泵变频装置",{"key":24,"text":132,"correct":22},"采用散热器的温控阀",{"key":27,"text":134,"correct":22},"采用热计量装置",{"key":31,"text":136,"correct":29},"采用自动排气装置",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":60,"analysis":34},880510,"就对大气臭氧层的破坏程度而言，下列( )的说法是不正确的。",[141,143,145,147],{"key":20,"text":142,"correct":22},"CFCs＜HCFCs＜HFCs",{"key":24,"text":144,"correct":22},"HCFCs＜CFCs＜HFCs",{"key":27,"text":146,"correct":29},"HFCs＜HCFCs＜CFCs",{"key":31,"text":148,"correct":22},"HFCs＜CFCs＜HCFCs",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":98,"analysis":34},880511,"下列消声设计计算法中，正确的是( )。",[153,155,157,159],{"key":20,"text":154,"correct":29},"空调设备噪声源的声功率级数据应采用产品样本中的计算分析数据",{"key":24,"text":156,"correct":22},"对于直管段，当风速小于5m\u002Fs时，可不计算气流再生噪声",{"key":27,"text":158,"correct":22},"对于直管段，当风速大于8m\u002Fs时，可不计算噪声自然衰减量",{"key":31,"text":160,"correct":22},"系统所需的消声量，应通过计算确定",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":173,"analysis":34},880512,"《公建节能》对集中供暖系统确定耗电输热比(EHR)的允许值与下列因素的关系，哪些是错误的？( )",[165,167,169,171],{"key":20,"text":166,"correct":29},"与室外供暖主管线的长度成正比",{"key":24,"text":168,"correct":29},"与设计供回水温差成反比",{"key":27,"text":170,"correct":22},"与管网的实际比摩阻成正比",{"key":31,"text":172,"correct":22},"与循环水泵的传动效率成反比","CD",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":111,"analysis":34},880513,"适合采用变风量空调系统的条件包括( )。",[178,180,182,184],{"key":20,"text":179,"correct":22},"需要分别调节各房间的室温",{"key":24,"text":181,"correct":29},"室温控制精度要求较高",{"key":27,"text":183,"correct":22},"采用全空气空调系统",{"key":31,"text":185,"correct":22},"同一个空调系统的各房间负荷变化较大、长期低负荷运行",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":98,"analysis":34},880514,"下列确定水表口径的原财，哪些是正确的？( )",[190,192,194,196],{"key":20,"text":191,"correct":29},"必须与管道接口管径一致",{"key":24,"text":193,"correct":22},"密集型用水系统应以设计秒流量选定水表的常用流量",{"key":27,"text":195,"correct":22},"住宅用水系统应以设计秒流量选定水表的过载流量",{"key":31,"text":197,"correct":22},"需要通过消防用水的系统(如小区合用管网)，应以生活用水的设计秒流量叠加消防用水量，不应大于水表的过载流量",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":210,"analysis":34},880515,"设计建筑室内排水系统时，设置通气系统的主要作用应是下列哪几项？( )",[202,204,206,208],{"key":20,"text":203,"correct":22},"保护存水弯的水封",{"key":24,"text":205,"correct":29},"排水管堵塞时清通的通道",{"key":27,"text":207,"correct":22},"排除污水产生的有害气体",{"key":31,"text":209,"correct":29},"建筑火灾时的安全措施","AC",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":111,"analysis":34},880516,"溴化锂水溶液的主要特征是( )。",[215,217,219,221],{"key":20,"text":216,"correct":22},"溴化锂水溶液的水蒸气分压力小，它比同温度下纯水的饱和蒸汽压力要小得多，所以具有较强的吸湿性",{"key":24,"text":218,"correct":29},"溴化锂水溶液的饱和温度与压力和浓度有关，在一定压力下，其饱和温度随浓度变化，浓度越大相应的饱和温度越低",{"key":27,"text":220,"correct":22},"溴化锂水溶液的温度过低或过高，均容易发生结晶",{"key":31,"text":222,"correct":22},"溴化锂水溶液对一般金属材料具有很强的腐蚀性，并且腐蚀产生的不凝性气体对制冷机的影响很大",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":111,"analysis":34},880517,"下列情况中，宜采用分层空调系统的是( )。",[227,229,230,231],{"key":20,"text":228,"correct":22},"建筑空间高度大于10m的飞机总装车间",{"key":24,"text":34,"correct":29},{"key":27,"text":34,"correct":22},{"key":31,"text":34,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":73,"analysis":34},880518,"下列关于空调风管的说法中，正确的是( )。",[236,238,240,242],{"key":20,"text":237,"correct":22},"风管的强度应能满足在1.5倍工作压力下接缝处无开裂",{"key":24,"text":239,"correct":22},"低压和中压圆形金属风管的允许漏风量为矩形风管的50%",{"key":27,"text":241,"correct":22},"低温送风系统风管的允许漏风量按中压系统风管的规定执行",{"key":31,"text":243,"correct":29},"净化空调系统风管的允许漏风量按高压系统风管的规定执行",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":111,"analysis":34},880519,"有关地板送风系统，下列说法正确的是哪些项?( )。",[248,250,252,254],{"key":20,"text":249,"correct":22},"地板送风的送风温度较置换通风低，系统所负担的冷负荷也大于置换通风",{"key":24,"text":251,"correct":29},"分层空调无论用于冬季还是夏季均有好的节能效果",{"key":27,"text":253,"correct":22},"地板送风应避免与其他气流组织形式应用于统一空调区",{"key":31,"text":255,"correct":22},"地板送风设计时应将热分层高度维持在室内人员活动区",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":73,"analysis":34},880520,"下列关于外部吸气罩控制风速的论述中，正确的是( )。",[260,262,264,266],{"key":20,"text":261,"correct":22},"控制风速是由外部吸气罩的抽吸作用造成的",{"key":24,"text":263,"correct":22},"外部吸气罩造成的实际控制风速随控制距离增加而迅速衰减",{"key":27,"text":265,"correct":22},"控制风速的选取应考虑有害物的毒性、散发状况及干扰气流大小等多种因素",{"key":31,"text":267,"correct":29},"需控制的粉尘粒径越大，相应的控制风速越高",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":33,"analysis":34},880521,"多层建筑中经常有人停留的地下室内4个面积不同的房间( )可不设排烟设施。",[272,274,276,278],{"key":20,"text":273,"correct":22},"35㎡",{"key":24,"text":275,"correct":22},"48㎡",{"key":27,"text":277,"correct":29},"52㎡",{"key":31,"text":279,"correct":29},"65㎡",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":210,"analysis":34},880522,"在分户采暖中，对于建筑物热力人口装置的说法不正确的是( )。",[284,286,288,290],{"key":20,"text":285,"correct":22},"户内采暖为单管跨越式定流量系统时，热力入口应设自力式压差控制阀",{"key":24,"text":287,"correct":29},"室内采暖为双管变流量时，热力入口应设自力式压差控制阀",{"key":27,"text":289,"correct":22},"热力入口供水管上应设三级过滤器",{"key":31,"text":291,"correct":29},"供回水管上应设必要的压力表或压力表管口",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":98,"analysis":34},880523,"按照《公建节能》的规定，在哪种情况下必须进行围护结构热工性能的权衡判断？( )",[296,298,300,302],{"key":20,"text":297,"correct":29},"体形系数小于或等于0.40",{"key":24,"text":299,"correct":22},"围护结构的热工性能指标不符合规定",{"key":27,"text":301,"correct":22},"个别朝向的窗墙面积比大于0.70",{"key":31,"text":303,"correct":22},"屋顶透明部分的面积大于屋顶总面积的20%",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":98,"analysis":34},880524,"各种排风系统排风口风帽的选择，不宜采用( )。",[308,310,312,314],{"key":20,"text":309,"correct":29},"利用热压和风压联合作用的自然通风系统--筒形风帽",{"key":24,"text":311,"correct":22},"一般的机械排风系统——筒形风帽",{"key":27,"text":313,"correct":22},"除尘系统——伞形风帽",{"key":31,"text":315,"correct":22},"排除有害气体的通风系统——锥形风帽",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":33,"analysis":34},880525,"空调水系统的变频水泵，在系统其他条件不变的情况下，减小其运行频率时，可能产生的变化是( )。",[320,322,324,326],{"key":20,"text":321,"correct":22},"扬程不变，流量减少",{"key":24,"text":323,"correct":22},"扬程减小，流量减少",{"key":27,"text":325,"correct":29},"扬程不变，流量增加",{"key":31,"text":327,"correct":29},"扬程减小，流量增加",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":111,"analysis":34},880526,"关于空调水管材料的选择表述中，正确的是( )。",[332,334,336,338],{"key":20,"text":333,"correct":22},"铜管比较光滑，与钢管相比，其流动阻力损失较小，因此水泵能耗较小",{"key":24,"text":335,"correct":29},"由于废钢管可以回收，而塑料水管不能回收，因此从环保的角度来说，空调水管不应采用塑料管",{"key":27,"text":337,"correct":22},"钢管的流动能耗比塑料水管大，因此采用塑料水管代替钢管是今后的发展方向",{"key":31,"text":339,"correct":22},"由于PVC管的导热性能差，因此冷凝水管宜采用PVC管取代镀锌钢管",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":342,"answer":60,"analysis":34},880527,[343,344,345,346],{"key":20,"text":34,"correct":22},{"key":24,"text":34,"correct":22},{"key":27,"text":34,"correct":29},{"key":31,"text":34,"correct":22},{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":173,"analysis":34},880528,"一制冷循环采用膨胀机代替膨胀阀，下列哪些说法是正确的？( )",[351,353,355,357],{"key":20,"text":352,"correct":29},"膨胀机和膨胀阀中的热力过程均为等焓过程",{"key":24,"text":354,"correct":29},"制冷剂在膨胀机中完成热力过程后，其状态为饱和液态",{"key":27,"text":356,"correct":22},"膨胀机中的理想热力过程为等熵膨胀过程",{"key":31,"text":358,"correct":22},"循环的制冷系数增大",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":210,"analysis":34},880529,"关于排风热回收装置的说法中，正确的是( )。",[363,365,367,369],{"key":20,"text":364,"correct":22},"寒冷地区空调系统排风热回收装置的夏季节能效果通常不如冬季",{"key":24,"text":366,"correct":29},"全热回收装置的热回收效率高，因此排风热回收都应采用全热回收装置",{"key":27,"text":368,"correct":22},"严寒地区空调排风热回收装置应采取防冻措施",{"key":31,"text":370,"correct":29},"排风热回收装置没有必要设置旁通风道",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":383,"analysis":34},880530,"下列哪些压缩机属于容积型回转式压缩机？( )",[375,377,379,381],{"key":20,"text":376,"correct":29},"活塞式压缩机",{"key":24,"text":378,"correct":22},"螺杆式压缩机",{"key":27,"text":380,"correct":22},"转子式压缩机",{"key":31,"text":382,"correct":29},"离心式压缩机","BC",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":73,"analysis":34},880531,"对于多层建筑物中的可燃气体管道，下列规定( )是正确的。",[388,390,392,394],{"key":20,"text":389,"correct":22},"不应穿过通风机房",{"key":24,"text":391,"correct":22},"不应穿过通风管道",{"key":27,"text":393,"correct":22},"不应紧贴通风管道外壁敷设",{"key":31,"text":395,"correct":29},"不宜紧贴通风管道外壁敷设",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":33,"analysis":34},880532,"对于R407C制冷剂，下列哪些说法是正确的？( )",[400,402,404,406],{"key":20,"text":401,"correct":22},"不破坏臭氧层",{"key":24,"text":403,"correct":22},"非共沸混合物、存在较大温度滑移",{"key":27,"text":405,"correct":29},"与R22相比具有较高的性能系数",{"key":31,"text":407,"correct":29},"不需要更换润滑油",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":60,"analysis":34},880533,"关于除尘器的效率，正确的是( )。",[412,414,416,418],{"key":20,"text":413,"correct":22},"效率是指除尘器除下的粉尘与进入除尘器的粉尘质量之比",{"key":24,"text":415,"correct":22},"分级效率是除尘器的重要性能指标之一",{"key":27,"text":417,"correct":29},"对一定型号的除尘器，其分级效率是不变的",{"key":31,"text":419,"correct":22},"除尘器的全效率与其分级效率和人口粉尘的粒径分布有关",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":98,"analysis":34},880534,"有关重力式循环系统的说法，正确的应是下列哪几项？",[424,426,428,430],{"key":20,"text":425,"correct":29},"重力循环系统采用双管系统比采用单管系统更易克服垂直水力失调现象",{"key":24,"text":427,"correct":22},"楼层散热器相对于热水锅炉的高度减小，提供的循环作用压力相应减小",{"key":27,"text":429,"correct":22},"重力循环系统是以不同温度的水的密度差为动力进行循环的系统",{"key":31,"text":431,"correct":22},"重力循环系统作用半径不宜超过50m",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":383,"analysis":34},880535,"对锅炉房设置备用锅炉，下列哪几项做法是错误的？",[436,438,440,442],{"key":20,"text":437,"correct":29},"住宅小区采暖锅炉房可不设备用锅炉",{"key":24,"text":439,"correct":22},"机械加工车间采暖锅炉房应设备用锅炉",{"key":27,"text":441,"correct":22},"以生产负荷为主的锅炉房，当非采暖期至少能停用一台锅炉进行检修时，应设备用锅炉",{"key":31,"text":443,"correct":29},"药厂发酵车间供发酵使用的应设备用锅炉",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":111,"analysis":34},880536,"下列措施有助于降低风机功耗的是( )。",[448,450,452,454],{"key":20,"text":449,"correct":22},"降低温差",{"key":24,"text":451,"correct":29},"降低流速",{"key":27,"text":453,"correct":22},"提高载能介质输送效率",{"key":31,"text":455,"correct":22},"提高设备部分负荷性能",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":98,"analysis":34},880537,"电子工业洁净厂房的机械排烟系统设计的要求是( )。",[460,462,464,466],{"key":20,"text":461,"correct":29},"厂房内各区域均设置机械排烟系统",{"key":24,"text":463,"correct":22},"洁净厂房中的疏散走廊应设置机械排烟系统",{"key":27,"text":465,"correct":22},"机械排烟系统宜与通风、净化空调系统分开设置；当合用时应采取防火安全措施，并应符合《建规》有关规定",{"key":31,"text":467,"correct":22},"同一防火分区的丙类洁净室(区)，人员密度小于0.02人\u002F㎡，且安全疏散距离小于80m时，洁净室(区)可不设机械排烟设施",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":33,"analysis":34},880538,"全面通风就是对整个房间进行通风换气。其目的在于( )。",[472,474,476,478],{"key":20,"text":473,"correct":22},"稀释室内有害物浓度",{"key":24,"text":475,"correct":22},"消除余热、余湿",{"key":27,"text":477,"correct":29},"防止烟气侵入作为疏散道路的走廊、楼梯间前室、楼梯间",{"key":31,"text":479,"correct":29},"保护建筑室内人员从有害的烟气环境中安全疏散",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":73,"analysis":34},880539,"供热系统中安全阀正确安装方式是下列哪几项？",[484,486,488,490],{"key":20,"text":485,"correct":22},"蒸汽管道和设备上的安全阀应有通向室外排气管",{"key":24,"text":487,"correct":22},"热力管道和设备上的安全阀应有接到安全地点排水管",{"key":27,"text":489,"correct":22},"在排水管和排气管上不得设置阀门",{"key":31,"text":491,"correct":29},"安全阀必须垂直安装",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":73,"analysis":34},880540,"提高蒸汽压缩螺杆式制冷机组的制冷能效比有若干措施，下列正确的应是哪几项？",[496,498,500,502],{"key":20,"text":497,"correct":22},"增大进入膨胀阀前的液体制冷剂的过冷度",{"key":24,"text":499,"correct":22},"减少冷凝器和蒸发器的传热温差",{"key":27,"text":501,"correct":22},"设置节能器",{"key":31,"text":503,"correct":29},"提高压缩比",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":111,"analysis":34},880541,"常用的空气处理系统中，可视为等焓加湿方式的应是下列哪几项？( )",[508,510,512,514],{"key":20,"text":509,"correct":22},"水喷雾加湿",{"key":24,"text":511,"correct":29},"喷干蒸汽加湿",{"key":27,"text":513,"correct":22},"循环水喷淋加湿",{"key":31,"text":515,"correct":22},"湿膜加湿",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":73,"analysis":34},880542,"采用单级制冷循环制取很低的蒸发温度时，会产生( )等有害因素。",[520,522,523,524],{"key":20,"text":521,"correct":22},"压缩机排气温度很高",{"key":24,"text":34,"correct":22},{"key":27,"text":34,"correct":22},{"key":31,"text":34,"correct":29},{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":537,"analysis":34},880543,"下列关于设备选择和布置的要求，正确的是( )。",[529,531,533,535],{"key":20,"text":530,"correct":22},"对于一般送排风系统，通风机附加5%～10%的风管与设备漏风量",{"key":24,"text":532,"correct":22},"对排烟兼排风系统，通风机附加10%～20%的风管与设备漏风量",{"key":27,"text":534,"correct":22},"选择空气加热器时也要考虑附加风管与设备的漏风量",{"key":31,"text":536,"correct":22},"排风系统的风机应尽量靠近室外布置","ABCD",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":98,"analysis":34},880544,"多层建筑中经常有人停留的地下室总面积大于( )时应设排烟设施。",[542,544,546,548],{"key":20,"text":543,"correct":29},"150㎡",{"key":24,"text":545,"correct":22},"200㎡",{"key":27,"text":547,"correct":22},"250㎡",{"key":31,"text":549,"correct":22},"300㎡",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":537,"analysis":34},880545,"关于风压、热压共同作用下的自然通风，下列说法正确的是( )。",[554,556,558,560],{"key":20,"text":555,"correct":22},"建筑物受风压和热压共同作用时，外围护结构各窗孔的内外压差等于风压、热压单独作用时窗孔内外压差之和",{"key":24,"text":557,"correct":22},"高层建筑在冬季，即使室外风速很大，上层迎风面房间仍然是排风，热压起了主导作用",{"key":27,"text":559,"correct":22},"低层建筑，较低的风速受周围建筑物或障碍物的影响很大，因此也影响了风压对建筑物的作用",{"key":31,"text":561,"correct":22},"实际工程设计计算时，仅考虑热压的作用，风压一般不予考虑",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":60,"analysis":34},880546,"居民燃气采暖装置的设置应( )。",[566,568,570,572],{"key":20,"text":567,"correct":22},"安装在通风良好的独立房间或厨房、阳台等非居住房间内",{"key":24,"text":569,"correct":22},"采暖装置应有熄火保护装置和排烟设施",{"key":27,"text":571,"correct":29},"容积式热水采暖炉应设置在通风良好的走廊或其他非居住房间内，与对面墙壁之间应有不小于1.5m的通道",{"key":31,"text":573,"correct":22},"采暖装置设置在可燃或易燃的地板上时，应采取有效的防火隔热措施",{"id":575,"libraryId":5,"type":576,"typeLabel":577,"stem":578,"options":579,"answer":24,"analysis":34},880547,1,"单选题","供暖系统采用适合于输送热介质的塑料管时，在计算条件中的温度因素应( )。",[580,582,584,586],{"key":20,"text":581,"correct":29},"按照热媒温度在任何情况下都不能超过70℃考虑",{"key":24,"text":583,"correct":22},"按照在要求的使用寿命期内，不同热媒温度的累计热作用考虑",{"key":27,"text":585,"correct":29},"按照热媒可能出现的最高温度考虑",{"key":31,"text":587,"correct":29},"按照热媒在正常条件下的平均温度考虑",{"id":589,"libraryId":5,"type":576,"typeLabel":577,"stem":590,"options":591,"answer":31,"analysis":34},880548,"下列哪一项不能实现燃气锅炉的节能？( )",[592,594,596,598],{"key":20,"text":593,"correct":29},"装设烟气热回收装置",{"key":24,"text":595,"correct":29},"采用比例控制的燃烧器",{"key":27,"text":597,"correct":29},"采用自动排污，减少锅炉排污量",{"key":31,"text":599,"correct":22},"提高排烟温度",{"id":601,"libraryId":5,"type":576,"typeLabel":577,"stem":602,"options":603,"answer":31,"analysis":34},880549,"关于居住建筑共用立管的分户独立的集中热水供暖系统，下列做法错误的是( )。",[604,606,608,610],{"key":20,"text":605,"correct":29},"每组共用立管连接户数一般不宜超过40户",{"key":24,"text":607,"correct":29},"共用立管的设计流速为1.20m\u002Fs",{"key":27,"text":609,"correct":29},"共用立管的比摩阻宜保持在30～60Pa\u002Fm",{"key":31,"text":611,"correct":22},"户内系统的计算压力损失(包括调节阀、户用热量表)不大于20kPa",{"id":613,"libraryId":5,"type":15,"typeLabel":16,"stem":614,"options":615,"answer":33,"analysis":34},880550,"居住商业混合区夜间环境A声级噪声值为( )是允许的。",[616,618,620,622],{"key":20,"text":617,"correct":22},"40dB",{"key":24,"text":619,"correct":22},"50dB",{"key":27,"text":621,"correct":29},"60dB",{"key":31,"text":623,"correct":29},"70dB",[625,628,631,634,637,640],{"id":576,"name":626,"category":7,"favorite":627},"领导干部任职前廉政法规知识测试题",92,{"id":629,"name":630,"category":7,"favorite":576},595,"建筑结构与设备",{"id":632,"name":633,"category":7,"favorite":576},715,"招标采购专业知识与法律法规",{"id":635,"name":636,"category":7,"favorite":576},848,"市政方向-通用基础",{"id":638,"name":639,"category":7,"favorite":8},534,"BIM工程师",{"id":641,"name":639,"category":7,"favorite":8},535]