[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":628},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,13,50,2054,[13,30,41,53,68,80,93,105,118,130,142,155,167,180,192,204,217,230,243,255,268,280,292,304,316,328,340,352,364,376,388,400,412,424,436,448,460,472,484,496,508,520,532,544,556,568,580,592,604,616],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":21},880451,1,"单选题","某住宅空调设计采用按户独立的多联机系统，无集中新风系统，其夏季空调冷负荷计算时，新风换气次数宜取下列何项?( )。",[19,23,26,28],{"key":20,"text":21,"correct":22},"A","",false,{"key":24,"text":21,"correct":25},"B",true,{"key":27,"text":21,"correct":22},"C",{"key":29,"text":21,"correct":22},"D",{"id":31,"libraryId":5,"type":15,"typeLabel":16,"stem":32,"options":33,"answer":27,"analysis":21},880452,"下列空调节能技术措施中不正确的是( )。",[34,36,37,39],{"key":20,"text":35,"correct":22},"过渡季节排风热回收装置应旁通",{"key":24,"text":21,"correct":22},{"key":27,"text":38,"correct":25},"住宅采用集中空调方案取代分体空调方案",{"key":29,"text":40,"correct":22},"减少水系统串联阀门的数量",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":29,"analysis":21},880453,"关于防空地下室防护通风的设计，下列哪一项正确？",[45,47,49,51],{"key":20,"text":46,"correct":22},"穿墙通风管，应采取可靠的防护密闭措施",{"key":24,"text":48,"correct":22},"战时为物资库的防空地下室，应在值班室设置测压装置",{"key":27,"text":50,"correct":22},"防爆波活门的额定风量不应小于战时隔绝式通风量",{"key":29,"text":52,"correct":25},"过滤吸收器的额定风量必须大于滤毒通风时的进风量",{"id":54,"libraryId":5,"type":55,"typeLabel":56,"stem":57,"options":58,"answer":67,"analysis":21},880454,2,"多选题","工业建筑物内有害物质产生与控制等说法，正确的是下列哪些项？",[59,61,63,65],{"key":20,"text":60,"correct":22},"有害物质产生由生产工艺决定，生产工艺可以通过实行清洁生产方式，以根本解决污染物问题",{"key":24,"text":62,"correct":22},"粉尘依靠自身的能量可以长期悬浮在车间的空气中",{"key":27,"text":64,"correct":25},"控制污染物扩散最有效的措施就是控制气流组织",{"key":29,"text":66,"correct":25},"排风系统抽吸的污染物越多，排风量越大，废气处理的代价就越大","CD",{"id":69,"libraryId":5,"type":55,"typeLabel":56,"stem":70,"options":71,"answer":79,"analysis":21},880455,"对袋式除尘器的过滤风速的论述，下列哪几项是正确的？( )",[72,74,76,78],{"key":20,"text":73,"correct":22},"袋式除尘器的过滤风速是指气体通过滤袋的风速，常用单位是m\u002Fs",{"key":24,"text":75,"correct":25},"袋式除尘器的过滤风速是指气体通过滤料面的平均风速，常用单位是m\u002Fmin",{"key":27,"text":77,"correct":22},"袋式除尘器的过滤风速是指气体通过袋式除尘器的断面风速，常用单位是m\u002Fmin",{"key":29,"text":21,"correct":25},"BD",{"id":81,"libraryId":5,"type":55,"typeLabel":56,"stem":82,"options":83,"answer":92,"analysis":21},880456,"为了有效控制洁净室内的污染浓度，一般可以采用的措施是( )。",[84,86,88,90],{"key":20,"text":85,"correct":25},"控制污染源，减少污染发生量",{"key":24,"text":87,"correct":25},"迅速有效地排除室内已经发生的污染",{"key":27,"text":89,"correct":25},"有效阻止室外的污染侵入室内",{"key":29,"text":91,"correct":22},"计算机控制","ABC",{"id":94,"libraryId":5,"type":55,"typeLabel":56,"stem":95,"options":96,"answer":92,"analysis":21},880457,"工业企业生产用气设备的燃气总阀门燃烧器阀门之间设置放散管的目的，应为下列哪几项？",[97,99,101,103],{"key":20,"text":98,"correct":25},"用气设备首次使用时，用来吹扫积存在燃气管道中的空气",{"key":24,"text":100,"correct":25},"用气设备长时间不用再次使用时，用来吹扫积存在燃气管道中的空气",{"key":27,"text":102,"correct":25},"用气设备停用时，利用放散管放出因总阀门关闭不严漏出的燃气",{"key":29,"text":104,"correct":22},"用于防止供应的燃气超压引起的安全隐患发生",{"id":106,"libraryId":5,"type":55,"typeLabel":56,"stem":107,"options":108,"answer":117,"analysis":21},880458,"关于空调制冷机房的设备布置，正确的是( )。",[109,111,113,115],{"key":20,"text":110,"correct":25},"机组与墙之间的净距离不小于1m，与配电柜的距离不小于1.5m",{"key":24,"text":112,"correct":25},"机组与机组或其他设备之间的净距离不小于1.2m",{"key":27,"text":114,"correct":22},"留有0.8倍蒸发器或冷凝器长度的维修距离",{"key":29,"text":116,"correct":25},"机房主要通道的宽度不小于1.5m","ABD",{"id":119,"libraryId":5,"type":55,"typeLabel":56,"stem":120,"options":121,"answer":67,"analysis":21},880459,"公共建筑内的空调区域设排风热回收装置的说法，下列哪些是正确的？",[122,124,126,128],{"key":20,"text":123,"correct":22},"显热回收装置应用于对室内空气品质要求很高的场所",{"key":24,"text":125,"correct":22},"夏热冬冷地区宜选用显热回收装置",{"key":27,"text":127,"correct":25},"寒冷地区宜选用显热回收装置",{"key":29,"text":129,"correct":25},"夏热冬冷地区宜选用全热回收装置",{"id":131,"libraryId":5,"type":55,"typeLabel":56,"stem":132,"options":133,"answer":92,"analysis":21},880460,"室内天然气管道如果需要时，可以和下列哪些其他管道共用一个管道竖井？( )",[134,136,138,140],{"key":20,"text":135,"correct":25},"给水管道",{"key":24,"text":137,"correct":25},"排水管道",{"key":27,"text":139,"correct":25},"暖气管道",{"key":29,"text":141,"correct":22},"排风管道",{"id":143,"libraryId":5,"type":55,"typeLabel":56,"stem":144,"options":145,"answer":154,"analysis":21},880461,"下列情况中不宜采用多联机空调方案的是( )。",[146,148,150,152],{"key":20,"text":147,"correct":22},"当采用空气源多联机供热时，冬季平均运行性能系数低于1.8",{"key":24,"text":149,"correct":25},"油污蒸气较多的场所",{"key":27,"text":151,"correct":25},"产生电磁波或高频波的场所",{"key":29,"text":153,"correct":25},"振动较大的场所","BCD",{"id":156,"libraryId":5,"type":55,"typeLabel":56,"stem":157,"options":158,"answer":79,"analysis":21},880462,"带节能器的二次吸气制冷循环可增加制冷量、减少功耗和提高制冷系数，试问下列哪几种制冷压缩机易于实现该种制冷循环？( )",[159,161,163,165],{"key":20,"text":160,"correct":22},"离心式制冷压缩机",{"key":24,"text":162,"correct":25},"涡旋式制冷压缩机",{"key":27,"text":164,"correct":22},"活塞式制冷压缩机",{"key":29,"text":166,"correct":25},"螺杆式制冷压缩机",{"id":168,"libraryId":5,"type":55,"typeLabel":56,"stem":169,"options":170,"answer":179,"analysis":21},880463,"下列空调冷凝水管的说法中，正确的是( )。",[171,173,175,177],{"key":20,"text":172,"correct":22},"坡度不小于0.005",{"key":24,"text":174,"correct":25},"采用排水塑料管或热镀锌钢管",{"key":27,"text":176,"correct":25},"应采取防结露措施",{"key":29,"text":178,"correct":22},"应直接接人排水系统","BC",{"id":181,"libraryId":5,"type":55,"typeLabel":56,"stem":182,"options":183,"answer":67,"analysis":21},880464,"某吸收式制冷机房的事故排风口与机械送风系统的进风口的水平距离为14m，事故排风口设置正确的是( )。",[184,186,188,190],{"key":20,"text":185,"correct":22},"事故排风口与进风口等高",{"key":24,"text":187,"correct":22},"事故排风口高于进风口5m",{"key":27,"text":189,"correct":25},"事故排风口高于进风口6m",{"key":29,"text":191,"correct":25},"事故排风口高于进风口8m",{"id":193,"libraryId":5,"type":55,"typeLabel":56,"stem":194,"options":195,"answer":154,"analysis":21},880465,"下列空气过滤器的检测方法，我国采用的有( )。",[196,198,200,202],{"key":20,"text":197,"correct":22},"比色法",{"key":24,"text":199,"correct":25},"质量法",{"key":27,"text":201,"correct":25},"钠焰法",{"key":29,"text":203,"correct":25},"油雾法",{"id":205,"libraryId":5,"type":55,"typeLabel":56,"stem":206,"options":207,"answer":216,"analysis":21},880466,"绿色建筑提倡利用可再生能源，属于可再生能源的是( )。",[208,210,212,214],{"key":20,"text":209,"correct":25},"太阳能",{"key":24,"text":211,"correct":25},"地热能",{"key":27,"text":213,"correct":25},"余热",{"key":29,"text":215,"correct":25},"废热","ABCD",{"id":218,"libraryId":5,"type":55,"typeLabel":56,"stem":219,"options":220,"answer":229,"analysis":21},880467,"某栋6层住宅建筑，设计热水集中供暖系统，错误的做法是( )。",[221,223,225,227],{"key":20,"text":222,"correct":25},"为保证户内双管系统的流量，热力入口设置定流量调节阀",{"key":24,"text":224,"correct":25},"为保证供暖系统的供暖能力，供暖系统的供回水干管计算，计入向邻户传热引起的耗热量",{"key":27,"text":226,"correct":22},"为延长热计量表使用寿命，将户用热计量表安装在回水管上",{"key":29,"text":228,"correct":22},"为保证热计量表不被堵塞，户用热计量表前设置过滤器","AB",{"id":231,"libraryId":5,"type":55,"typeLabel":56,"stem":232,"options":233,"answer":242,"analysis":21},880468,"蒸汽采暖系统中疏水器的作用，下列哪几项是正确的？",[234,236,238,240],{"key":20,"text":235,"correct":25},"阻止蒸汽遗漏",{"key":24,"text":237,"correct":22},"定压",{"key":27,"text":239,"correct":25},"排出设备管道中凝结水",{"key":29,"text":241,"correct":25},"排出空气","ACD",{"id":244,"libraryId":5,"type":55,"typeLabel":56,"stem":245,"options":246,"answer":92,"analysis":21},880469,"关于空调水系统循环水泵设置原则的表述，错误的是( )。",[247,249,251,253],{"key":20,"text":248,"correct":25},"二次泵系统一定比一次泵系统节能",{"key":24,"text":250,"correct":25},"管道局部阻力和水泵扬程均取10%的安全因数",{"key":27,"text":252,"correct":25},"由.于冬季和夏季的水流量和水温不同，因此采暖和空调水泵应分开设置",{"key":29,"text":254,"correct":22},"3台水泵并联工作时，可以不设备用水泵",{"id":256,"libraryId":5,"type":55,"typeLabel":56,"stem":257,"options":258,"answer":267,"analysis":21},880470,"下列关于高层建筑加压送风系统的设计要求，正确的是( )。",[259,261,263,265],{"key":20,"text":260,"correct":25},"防烟楼梯间正压为40～50Pa，加压风口宜每隔2～3层设置1个",{"key":24,"text":262,"correct":22},"一个剪刀楼梯间应分别设置2个加压送风系统",{"key":27,"text":264,"correct":25},"层数超过32层的防烟楼梯间，其送风系统和送风量应分段设计",{"key":29,"text":266,"correct":22},"设加压送风的防烟楼梯间，无外窗的前室应设加压送风系统","AC",{"id":269,"libraryId":5,"type":55,"typeLabel":56,"stem":270,"options":271,"answer":242,"analysis":21},880471,"关于压缩比太大所带来的问题，下列说法正确的是( )。",[272,274,276,278],{"key":20,"text":273,"correct":25},"过热损失与节流损失大，导致制冷系数减少",{"key":24,"text":275,"correct":22},"单位容积制冷量增大，势必要求较大的压缩机",{"key":27,"text":277,"correct":25},"排气温度升高，导致压缩机润滑油黏度下降，润滑效果下降，功率消耗增加",{"key":29,"text":279,"correct":25},"导致压缩机容积效率减少，当压缩比达到20左右时，往复式压缩机的容积效率接近于零",{"id":281,"libraryId":5,"type":55,"typeLabel":56,"stem":282,"options":283,"answer":154,"analysis":21},880472,"关于粉尘的粒径分布，正确的是( )。",[284,286,288,290],{"key":20,"text":285,"correct":22},"粒径分布是指粉尘粒径所分布的范围",{"key":24,"text":287,"correct":25},"粒径分布是指粉尘群中各种不同粒径尘粒所占的百分数",{"key":27,"text":289,"correct":25},"有质量粒径分布和计数粒径分布等不同表示方式",{"key":29,"text":291,"correct":25},"粒径分布与除尘器的实际除尘效率密切相关",{"id":293,"libraryId":5,"type":55,"typeLabel":56,"stem":294,"options":295,"answer":242,"analysis":21},880473,"下列哪些制冷剂可作为R22的替代制冷剂？( )",[296,298,300,302],{"key":20,"text":297,"correct":25},"R404A",{"key":24,"text":299,"correct":22},"R134a",{"key":27,"text":301,"correct":25},"R410A",{"key":29,"text":303,"correct":25},"R32",{"id":305,"libraryId":5,"type":55,"typeLabel":56,"stem":306,"options":307,"answer":92,"analysis":21},880474,"给水系统设置止回阀的部位和目的是( )。",[308,310,312,314],{"key":20,"text":309,"correct":25},"水泵出水管上，防止停泵时水倒流",{"key":24,"text":311,"correct":25},"密闭的水加热系统的给水管上，防止热水进入给水系统",{"key":27,"text":313,"correct":25},"高位水箱当进出水管为同一条时安装在出水管上，保证出水管的正确流向",{"key":29,"text":315,"correct":22},"便器冲洗管处，防止污水倒流污染给水系统",{"id":317,"libraryId":5,"type":55,"typeLabel":56,"stem":318,"options":319,"answer":242,"analysis":21},880475,"对于一个现有的空调水系统，分别采用节流调节和变频调节方式将系统流量下调到额定流量的80%，下列说法中不正确的是( )。",[320,322,324,326],{"key":20,"text":321,"correct":25},"变频调节方式可使水泵效率提高",{"key":24,"text":323,"correct":22},"节流调节时水泵扬程增加",{"key":27,"text":325,"correct":25},"节流调节比变频调节更节能",{"key":29,"text":327,"correct":25},"节流调节会使水泵能耗增加",{"id":329,"libraryId":5,"type":55,"typeLabel":56,"stem":330,"options":331,"answer":67,"analysis":21},880476,"某建筑面积为5000㎡的办公楼采用变制冷剂流量多联分体式空气调节系统，其新风供应方案选择正确的是哪几项？",[332,334,336,338],{"key":20,"text":333,"correct":22},"开窗获取新风",{"key":24,"text":335,"correct":22},"风机直接进入新风到室内机的回风处",{"key":27,"text":337,"correct":25},"设置新风机组",{"key":29,"text":339,"correct":25},"采用全热交换装置",{"id":341,"libraryId":5,"type":55,"typeLabel":56,"stem":342,"options":343,"answer":92,"analysis":21},880477,"下列确定空调系统最小新风量的因素中，应考虑( )。",[344,346,348,350],{"key":20,"text":345,"correct":25},"人员呼吸对新风量的要求",{"key":24,"text":347,"correct":25},"保持室内正压对新风量的要求",{"key":27,"text":349,"correct":25},"稀释和排除有害气体对新风量的要求",{"key":29,"text":351,"correct":22},"排除余热和余湿对新风量的要求",{"id":353,"libraryId":5,"type":55,"typeLabel":56,"stem":354,"options":355,"answer":242,"analysis":21},880478,"有一建筑高度小于50m的一类公共建筑，裙房以上部分的防烟楼梯间及合用前室具有可开启外窗，具备自然排烟条件。裙房以内部分无外窗，不具备自然排烟条件，其防排烟设施按( )设置是不符合通常做法的。",[356,358,360,362],{"key":20,"text":357,"correct":25},"不考虑裙房以上部分具备自然排烟条件，对整个防烟楼梯间及合用前室设置机械加压送风设施",{"key":24,"text":359,"correct":22},"对裙房部分设置局部机械加压送风设施，裙房以上部分采用自然排烟",{"key":27,"text":361,"correct":25},"裙房以上部分采用自然排烟，裙房部分设置局部机械排烟设施",{"key":29,"text":363,"correct":25},"裙房以上部分采用自然排烟，裙房部分不设置防排烟设施",{"id":365,"libraryId":5,"type":55,"typeLabel":56,"stem":366,"options":367,"answer":79,"analysis":21},880479,"《公建节能》提出的节能50%是指( )。",[368,370,372,374],{"key":20,"text":369,"correct":22},"以《寒冷标准》规定的节能30%为比较基础",{"key":24,"text":371,"correct":25},"对20世纪80年代初期建造的公共建筑能耗作为比较基础",{"key":27,"text":373,"correct":22},"由改善围护结构的热工性能和提高空调供暖设备的效率来实现",{"key":29,"text":375,"correct":25},"由改善围护结构的热工性能、提高空调供暖设备和照明设备的效率来实现",{"id":377,"libraryId":5,"type":55,"typeLabel":56,"stem":378,"options":379,"answer":117,"analysis":21},880480,"关于吊顶辐射空调方式，下列说法中错误的是( )。",[380,382,384,386],{"key":20,"text":381,"correct":25},"夏季水温提高冷却能力急剧降低，因此夏季供水温度应尽可能降低",{"key":24,"text":383,"correct":25},"冬季辐射吊顶通过辐射方式直接将热量传给人体，使人感到舒适",{"key":27,"text":385,"correct":22},"吊顶辐射空调不适用于热湿负荷较大的场合",{"key":29,"text":387,"correct":25},"室内辐射吊顶可以负担室内全部空调冷负荷",{"id":389,"libraryId":5,"type":55,"typeLabel":56,"stem":390,"options":391,"answer":79,"analysis":21},880481,"寒冷地区公共建筑外窗传热系数的限值，与哪些因素有关？( )",[392,394,396,398],{"key":20,"text":393,"correct":22},"窗的朝向",{"key":24,"text":395,"correct":25},"窗墙面积比",{"key":27,"text":397,"correct":22},"建筑高度",{"key":29,"text":399,"correct":25},"建筑物的体形系数",{"id":401,"libraryId":5,"type":55,"typeLabel":56,"stem":402,"options":403,"answer":79,"analysis":21},880482,"蓄冷系统的供冷负荷计算基数和设计依据是( )。",[404,406,408,410],{"key":20,"text":405,"correct":22},"设计日的最大小时负荷",{"key":24,"text":407,"correct":25},"设计日的日负荷",{"key":27,"text":409,"correct":22},"设计日的平均负荷",{"key":29,"text":411,"correct":25},"设计日逐时负荷分布图",{"id":413,"libraryId":5,"type":55,"typeLabel":56,"stem":414,"options":415,"answer":423,"analysis":21},880483,"下列关于自然通风的叙述中，正确的是( )。",[416,418,420,421],{"key":20,"text":417,"correct":25},"排除建筑内余热余湿的通风系统应优先采用自然通风",{"key":24,"text":419,"correct":22},"民用建筑的卧室和起居室应采用自然通风",{"key":27,"text":21,"correct":22},{"key":29,"text":422,"correct":25},"对进风有净化或温湿度要求时，不得采用自然进风","AD",{"id":425,"libraryId":5,"type":55,"typeLabel":56,"stem":426,"options":427,"answer":179,"analysis":21},880484,"下列哪些场所可以推广采用蓄冷技术？( )",[428,430,432,434],{"key":20,"text":429,"correct":22},"电信机房",{"key":24,"text":431,"correct":25},"影剧院、体育馆",{"key":27,"text":433,"correct":25},"空调逐时负荷峰谷差悬殊的工厂",{"key":29,"text":435,"correct":22},"部队营房",{"id":437,"libraryId":5,"type":55,"typeLabel":56,"stem":438,"options":439,"answer":229,"analysis":21},880485,"在进行冬季全面通风换气的热风平衡计算时，下列论述正确的是( )。",[440,442,444,446],{"key":20,"text":441,"correct":25},"在允许范围内适当提高集中送风的送风温度",{"key":24,"text":443,"correct":25},"对于允许短时过冷的室内可不考虑热和空气平衡",{"key":27,"text":445,"correct":22},"用于选择机械送风系统加热器的冬季室外温度应采用冬季通风室外计算温度",{"key":29,"text":447,"correct":22},"用于消除余热、余湿的全面通风耗热量的冬季室外温度应采用冬季供暖室外计算温度",{"id":449,"libraryId":5,"type":55,"typeLabel":56,"stem":450,"options":451,"answer":229,"analysis":21},880486,"关于风机盘管+新风空调系统热水温度的选取中，合理的是( )。",[452,454,456,458],{"key":20,"text":453,"correct":25},"夏热冬冷地区供回水温度为60℃\u002F50℃",{"key":24,"text":455,"correct":25},"寒冷地区供回水温度为70℃\u002F55℃",{"key":27,"text":457,"correct":22},"严寒地区供回水温度为75℃\u002F50℃",{"key":29,"text":459,"correct":22},"严寒地区供回水温度为80℃\u002F60℃",{"id":461,"libraryId":5,"type":55,"typeLabel":56,"stem":462,"options":463,"answer":117,"analysis":21},880487,"关于人防工程的通风设计，过滤吸收器的额定风量的确定，哪几项是错误的？",[464,466,468,470],{"key":20,"text":465,"correct":25},"不小于最大的计算新风量",{"key":24,"text":467,"correct":25},"不小于战时清洁通风的计算新风量",{"key":27,"text":469,"correct":22},"不小于战时滤毒通风的计算新风量",{"key":29,"text":471,"correct":25},"不小于战时要求的隔绝通风量",{"id":473,"libraryId":5,"type":55,"typeLabel":56,"stem":474,"options":475,"answer":216,"analysis":21},880488,"低温热水辐射供暖地板表面平均温度与下列哪些因素有关？( )",[476,478,480,482],{"key":20,"text":477,"correct":25},"单位地面面积散热量",{"key":24,"text":479,"correct":25},"室内计算温度",{"key":27,"text":481,"correct":25},"供水温度",{"key":29,"text":483,"correct":25},"加热管间距",{"id":485,"libraryId":5,"type":55,"typeLabel":56,"stem":486,"options":487,"answer":92,"analysis":21},880489,"下列关于办公建筑空调新风问题的说法中，正确的是( )。",[488,490,492,494],{"key":20,"text":489,"correct":25},"没有设置排风会造成室内新风量不足",{"key":24,"text":491,"correct":25},"适当开窗是解决室内通风换气问题的一种简易方法",{"key":27,"text":493,"correct":25},"辐射空调夏季不能开窗通风",{"key":29,"text":495,"correct":22},"开窗会使空调能耗增大，因此外窗应按不可开启设计，以杜绝开窗现象",{"id":497,"libraryId":5,"type":55,"typeLabel":56,"stem":498,"options":499,"answer":92,"analysis":21},880490,"采用热风供暖的条件是( )。",[500,502,504,506],{"key":20,"text":501,"correct":25},"能与机械送风合并",{"key":24,"text":503,"correct":25},"利用循环空气供暖技术经济合理",{"key":27,"text":505,"correct":25},"由于卫生等要求需要全新风时的供暖",{"key":29,"text":507,"correct":22},"有易燃、易爆、有毒气体",{"id":509,"libraryId":5,"type":55,"typeLabel":56,"stem":510,"options":511,"answer":92,"analysis":21},880491,"下列关于高压蒸汽采暖系统凝结水管的设计，正确的是( )。",[512,514,516,518],{"key":20,"text":513,"correct":25},"疏水器前凝结水管不应向上抬升",{"key":24,"text":515,"correct":25},"疏水器后的凝结水管向上抬升的高度应当计算确定",{"key":27,"text":517,"correct":25},"本身无止回功能的疏水器后的凝水管上抬时，应设置止回阀",{"key":29,"text":519,"correct":22},"凝结水管必须设在散热设备下部",{"id":521,"libraryId":5,"type":55,"typeLabel":56,"stem":522,"options":523,"answer":216,"analysis":21},880492,"下列哪些说法符合冷热电三联供系统的设计原则？( )",[524,526,528,530],{"key":20,"text":525,"correct":25},"应优化系统配置",{"key":24,"text":527,"correct":25},"满足能源梯级利用的要求",{"key":27,"text":529,"correct":25},"最大限度地利用能量",{"key":29,"text":531,"correct":25},"将输送环节损耗降至最低",{"id":533,"libraryId":5,"type":55,"typeLabel":56,"stem":534,"options":535,"answer":92,"analysis":21},880493,"关于洁净室空气过滤器，下列哪些说法是正确的？",[536,538,540,542],{"key":20,"text":537,"correct":25},"空气过滤器按效率可以分为粗效、中效(高中效)、亚高效、高效",{"key":24,"text":539,"correct":25},"空气过滤器的效率有计重效率、计数效率、比色效率",{"key":27,"text":541,"correct":25},"两个效率为90%的过滤器串联使用后的效率为99%",{"key":29,"text":543,"correct":22},"实测受检高效空气过滤器的穿透率，不应大于出厂合格穿透率的3倍",{"id":545,"libraryId":5,"type":55,"typeLabel":56,"stem":546,"options":547,"answer":154,"analysis":21},880494,"确定热水供暖散热器的传热系数或散热量的温度因素有( )。",[548,550,552,554],{"key":20,"text":549,"correct":22},"供暖室外计算温度",{"key":24,"text":551,"correct":25},"散热器的供水温度",{"key":27,"text":553,"correct":25},"散热器的回水温度",{"key":29,"text":555,"correct":25},"供暖房间计算温度",{"id":557,"libraryId":5,"type":55,"typeLabel":56,"stem":558,"options":559,"answer":229,"analysis":21},880495,"防止冷库地面冻胀的措施为( )。",[560,562,564,566],{"key":20,"text":561,"correct":25},"架空地坪",{"key":24,"text":563,"correct":25},"电加热地坪",{"key":27,"text":565,"correct":22},"地坪设隔热层",{"key":29,"text":567,"correct":22},"地坪设隔汽、防潮层",{"id":569,"libraryId":5,"type":55,"typeLabel":56,"stem":570,"options":571,"answer":216,"analysis":21},880496,"某安装柜式空调机组(配有变频调速装置)的空调系统，在供电频率为50Hz时，测得机组出口风量为20000m3／h、余压500Pa，当供电频率调至40Hz时，下列哪几项是正确的？",[572,574,576,578],{"key":20,"text":573,"correct":25},"出口风量约16000m3\u002Fh",{"key":24,"text":575,"correct":25},"出口余压约320Pa",{"key":27,"text":577,"correct":25},"系统的阻力约下降了36%",{"key":29,"text":579,"correct":25},"机组风机的轴功率约下降了48.8%",{"id":581,"libraryId":5,"type":55,"typeLabel":56,"stem":582,"options":583,"answer":92,"analysis":21},880497,"关于疏水器，下列说法正确的是( )。",[584,586,588,590],{"key":20,"text":585,"correct":25},"疏水器后有背压或凝结水管有抬高时，应在疏水器后装止回阀",{"key":24,"text":587,"correct":25},"疏水器前应设过滤器",{"key":27,"text":589,"correct":25},"高压蒸汽系统疏水器前应有伸缩器",{"key":29,"text":591,"correct":22},"蒸汽量小于200kg\u002Fh的凝水系统的疏水器应设置旁通管",{"id":593,"libraryId":5,"type":55,"typeLabel":56,"stem":594,"options":595,"answer":179,"analysis":21},880498,"下列关于消火栓栓口压力的说法，正确的是( )。",[596,598,600,602],{"key":20,"text":597,"correct":22},"消火栓栓口最高静水压力不应超过0.7MPa",{"key":24,"text":599,"correct":25},"消火栓栓口出水压力不应超过0.5MPa",{"key":27,"text":601,"correct":25},"消火栓栓口最高静水压力不应超过0.8MPa",{"key":29,"text":603,"correct":22},"消火栓栓口出水压力不应超过0.4MPa",{"id":605,"libraryId":5,"type":55,"typeLabel":56,"stem":606,"options":607,"answer":117,"analysis":21},880499,"关于热力完善度下列说法正确的是( )。",[608,610,612,614],{"key":20,"text":609,"correct":25},"热力完善度是工作于相同温度间的实际循环的制冷系数与逆卡诺循环制冷系数之比",{"key":24,"text":611,"correct":25},"热力完善度数值越大，说明制冷循环的不可逆损失越小",{"key":27,"text":613,"correct":22},"热力完善度数值越小，说明制冷循环的不可逆损失越小",{"key":29,"text":615,"correct":25},"热力完善度同时考虑了能力转换的数量关系和实际循环之不可逆的影响",{"id":617,"libraryId":5,"type":55,"typeLabel":56,"stem":618,"options":619,"answer":117,"analysis":21},880500,"大型计算机房使用普通柜式商用空调机可能会有缺陷。下列哪几项是正确的？( )",[620,622,624,626],{"key":20,"text":621,"correct":25},"风量不足且过滤效果差",{"key":24,"text":623,"correct":25},"机房湿度过低，造成有破坏性的静电",{"key":27,"text":625,"correct":22},"机房湿度过高，造成计算机元件无法正常工作",{"key":29,"text":627,"correct":25},"局部环境可能过热，导致电子设备突然关机",[629,632,635,638,641,644],{"id":15,"name":630,"category":7,"favorite":631},"领导干部任职前廉政法规知识测试题",92,{"id":633,"name":634,"category":7,"favorite":15},595,"建筑结构与设备",{"id":636,"name":637,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":639,"name":640,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":642,"name":643,"category":7,"favorite":8},534,"BIM工程师",{"id":645,"name":643,"category":7,"favorite":8},535]