[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-12":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":595},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,12,50,2054,[13,33,45,57,69,81,93,105,117,129,137,149,160,168,180,192,200,212,224,236,248,260,272,284,292,304,315,327,339,351,363,375,387,399,411,419,431,443,455,467,479,491,503,515,527,539,551,559,571,583],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":17},880401,1,"单选题","",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","9，不多于6次\u002Fh",false,{"key":24,"text":25,"correct":22},"B","9，不少于6次\u002Fh",{"key":27,"text":28,"correct":29},"C","9，不少于7次\u002Fh",true,{"key":31,"text":32,"correct":22},"D","9，不多于7次\u002Fh",{"id":34,"libraryId":5,"type":15,"typeLabel":16,"stem":35,"options":36,"answer":27,"analysis":17},880402,"热水供热管网与热用户采用混水泵的直接连接方式，主要是因为( )。",[37,39,41,43],{"key":20,"text":38,"correct":22},"供热管网的供回水压差不能满足热用户系统的循环要求",{"key":24,"text":40,"correct":22},"供热管网的压力与热用户系统的压力要求不相适应",{"key":27,"text":42,"correct":29},"供热管网的水温与热用户系统的水温要求不相适应",{"key":31,"text":44,"correct":22},"供热管网的压力和水温与热用户系统的要求均不相适应",{"id":46,"libraryId":5,"type":15,"typeLabel":16,"stem":47,"options":48,"answer":31,"analysis":17},880403,"对于上海地区精装修住宅，开发商明确送空调供暖设备，下列哪项不属于《绿建标准》规定要求？( )",[49,51,53,55],{"key":20,"text":50,"correct":22},"分体空调选用《单元式空气调节机能效限定值及能源效率等级》规定的第2级节能型产品",{"key":24,"text":52,"correct":22},"空气源热泵机组冬季COP不小于1.8",{"key":27,"text":54,"correct":22},"户式壁挂燃气炉的额定热效率不低于89%，部分负荷下的热效率不低于85%",{"key":31,"text":56,"correct":29},"需采用CFC制冷剂",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":24,"analysis":17},880404,"在设计采暖系统时，正确布置散热设备与选择附件的做法是下列哪一项？",[61,63,65,67],{"key":20,"text":62,"correct":22},"采用活塞式减压阀，减压后的压力0.08MPa",{"key":24,"text":64,"correct":29},"某蒸汽系统的安全阀通向室外的排气管管径为4.5cm",{"key":27,"text":66,"correct":22},"为了缓冲空气直接进入室内，在门斗处设置散热器",{"key":31,"text":68,"correct":22},"采用气压罐定压时，系统补水量可取总容水量的2%",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":27,"analysis":17},880405,"下列不是计算集中供热中供暖设计热负荷方法的是( )。",[73,75,77,79],{"key":20,"text":74,"correct":22},"体积热指标法",{"key":24,"text":76,"correct":22},"面积热指标法",{"key":27,"text":78,"correct":29},"百分率法",{"key":31,"text":80,"correct":22},"城市规划指标法",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":31,"analysis":17},880406,"新建住宅的热水集中供暖系统设计的下列要点中，哪一项是错误的？( )",[85,87,89,91],{"key":20,"text":86,"correct":22},"应设置分户热计量和室温控制装置",{"key":24,"text":88,"correct":22},"住宅内的公共用房和公共空间，应单独设置供暖系统",{"key":27,"text":90,"correct":22},"应在建筑物热力人口处设置热量表",{"key":31,"text":92,"correct":29},"应计算向邻户传热因素引起的负荷，并计入热源系统的总负荷内",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":20,"analysis":17},880407,"不同级别的洁净室以及洁净区与非洁净区的压差、洁净区与室外的压差分别不小于( )。",[97,99,101,103],{"key":20,"text":98,"correct":29},"5Pa，10Pa",{"key":24,"text":100,"correct":22},"10Pa，15Pa",{"key":27,"text":102,"correct":22},"15Pa，20Pa",{"key":31,"text":104,"correct":22},"25Pa，30Pa",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":31,"analysis":17},880408,"湍球塔的空塔速度一般为( )m\u002Fs。",[109,111,113,115],{"key":20,"text":110,"correct":22},"2～6",{"key":24,"text":112,"correct":22},"1～4",{"key":27,"text":114,"correct":22},"3～6",{"key":31,"text":116,"correct":29},"2～5",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":24,"analysis":17},880409,"一台本身不带隔振装置的设备，转数为1200r\u002Fmin，在隔振方面应选用( )。",[121,123,125,127],{"key":20,"text":122,"correct":22},"橡胶隔振器",{"key":24,"text":124,"correct":29},"弹簧隔振器",{"key":27,"text":126,"correct":22},"橡胶隔振垫",{"key":31,"text":128,"correct":22},"不需隔振",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":20,"analysis":17},880410,"如下所示，下列楼梯间的加压送风口的设置何项是正确的？其中A为防烟楼梯间，B为防烟楼梯间，C为消防电梯前室，D为消防电梯前室。( )。",[133,134,135,136],{"key":20,"text":17,"correct":29},{"key":24,"text":17,"correct":22},{"key":27,"text":17,"correct":22},{"key":31,"text":17,"correct":22},{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":31,"analysis":17},880411,"某城市一公路隧道封闭段长度为480m，准许各种机动车辆通行，满足设计防火规范规定，设计隧道的经济通风方式应是下列哪一项？",[141,143,145,147],{"key":20,"text":142,"correct":22},"自然通风",{"key":24,"text":144,"correct":22},"半横向通风",{"key":27,"text":146,"correct":22},"横向通风",{"key":31,"text":148,"correct":29},"纵向通风",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":151,"answer":31,"analysis":17},880412,[152,154,156,158],{"key":20,"text":153,"correct":22},"70kPa",{"key":24,"text":155,"correct":22},"80kPa",{"key":27,"text":157,"correct":22},"90kPa",{"key":31,"text":159,"correct":29},"100kPa",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":24,"analysis":17},880413,"某工厂一车间采暖热媒为高压蒸汽，蒸汽压力为0.7MPa，温度为200℃，中哪一项管道连接布置方式不会产生严重水击现象？",[164,165,166,167],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":29},{"key":27,"text":17,"correct":22},{"key":31,"text":17,"correct":22},{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":20,"analysis":17},880414,"非单向流洁净室的室内A声级噪声级(空态)不应大于下列哪一项？( )",[172,174,176,178],{"key":20,"text":173,"correct":29},"60dB",{"key":24,"text":175,"correct":22},"62dB",{"key":27,"text":177,"correct":22},"65dB",{"key":31,"text":179,"correct":22},"70dB",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":20,"analysis":17},880415,"关于空调冷热源的说法中，错误的是( )。",[184,186,188,190],{"key":20,"text":185,"correct":29},"直燃式冷水机组比螺杆式冷水机组节能，因此燃气空调对环境的影响较小",{"key":24,"text":187,"correct":22},"在相同的设计条件下，地下水地源热泵冷热水机组的能耗可能比空气源热泵冷热水机组大",{"key":27,"text":189,"correct":22},"夏季冷负荷和冬季热负荷相差较大的建筑，不宜采用地源热泵空调系统",{"key":31,"text":191,"correct":22},"电蓄热锅炉的一次能源消耗量比燃煤锅炉大",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":27,"analysis":17},880416,"对下列锅炉房进行通风设计时，( )项要求是不合理的。",[196,197,198,199],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":22},{"key":27,"text":17,"correct":29},{"key":31,"text":17,"correct":22},{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":27,"analysis":17},880417,"空调系统风机选择原则中，不正确的是( )。",[204,206,208,210],{"key":20,"text":205,"correct":22},"从节能的角度，应尽可能选择离心风机",{"key":24,"text":207,"correct":22},"风机的风量应考虑1.1的安全系数",{"key":27,"text":209,"correct":29},"从降低噪声的角度，应选择轴流风机",{"key":31,"text":211,"correct":22},"空调系统的风机宜采用离心风机",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":20,"analysis":17},880418,"测定风机的静压、动压和全压，下列说法错误的是哪一项？",[216,218,220,222],{"key":20,"text":217,"correct":29},"风机的入口静压一定是负值",{"key":24,"text":219,"correct":22},"风机的入口全压可能是正值，也可能是负值",{"key":27,"text":221,"correct":22},"风机的人口动压一定是正值",{"key":31,"text":223,"correct":22},"风机出口的全压、动压、静压一定都是正值",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":27,"analysis":17},880419,"洁净室内风管与管道的绝热材料可采用下列哪一项？( )",[228,230,232,234],{"key":20,"text":229,"correct":22},"玻璃棉",{"key":24,"text":231,"correct":22},"岩棉",{"key":27,"text":233,"correct":29},"闭孔橡塑泡沫",{"key":31,"text":235,"correct":22},"硅酸铝棉",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":31,"analysis":17},880420,"下列热泵机组的说法，错误的是( )。",[240,242,244,246],{"key":20,"text":241,"correct":22},"地埋管热泵机组的地埋管换热系统宜采用变流量设计",{"key":24,"text":243,"correct":22},"地埋管热泵机组的地埋管换热系统，夏季是向土壤释热",{"key":27,"text":245,"correct":22},"热泵热水机所供应的热水温度越高，机组制热能效比越低",{"key":31,"text":247,"correct":29},"热泵机组空调系统的节能效果与效益大小仅取决于低区气候特性的因素",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":31,"analysis":17},880421,"Igp-h(压-焓)图在制冷循环的热力计算上得到广泛应用，是因为( )。",[252,254,256,258],{"key":20,"text":253,"correct":22},"在图上容易绘出制冷循环",{"key":24,"text":255,"correct":22},"其吸、放热量可用画积表示",{"key":27,"text":257,"correct":22},"查取有关热力参数容易",{"key":31,"text":259,"correct":29},"吸、放热量和耗功量均可利用过程初、终状态的比焓差计算",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":27,"analysis":17},880422,"地面辐射供暖系统细石混凝土填充层进行膨胀补偿时，错误的做法是( )。",[264,266,268,270],{"key":20,"text":265,"correct":22},"地板面积为35㎡，每隔5m填充层留5mm宽的伸缩缝",{"key":24,"text":267,"correct":22},"地面长边7m，每隔6m填充层留10mm宽的伸缩缝",{"key":27,"text":269,"correct":29},"盘管穿越伸缩缝时，应设刚性套管",{"key":31,"text":271,"correct":22},"墙与地交接处的填充层留有5mm宽的伸缩缝",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":31,"analysis":17},880423,"下列对风管系统的设计要求哪项是错误的？( )",[276,278,280,282],{"key":20,"text":277,"correct":22},"各并联环路的压力损失相对差额不宜超过15%",{"key":24,"text":279,"correct":22},"并联运行的多台通风机应在各自的管路上设置可分别关断的装置",{"key":27,"text":281,"correct":22},"应在主干支管的适当部位设置可开启的检查和清扫用孔口",{"key":31,"text":283,"correct":29},"高温烟气管道宜考虑热补偿措施",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":31,"analysis":17},880424,"高层民用建筑中的封闭避难层净面积为500㎡，应怎样进行防排烟设计？( )",[288,289,290,291],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":22},{"key":27,"text":17,"correct":22},{"key":31,"text":17,"correct":29},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":24,"analysis":17},880425,"直燃溴化锂吸收式冷热水机组属于低压容器，在设计机房时应考虑下列哪一项？( )",[296,298,300,302],{"key":20,"text":297,"correct":22},"不需要考虑安全、防火问题",{"key":24,"text":299,"correct":29},"需要考虑安全、防火问题",{"key":27,"text":301,"correct":22},"虽有安全、防火问题，但无规范可循，无法考虑",{"key":31,"text":303,"correct":22},"安全、防火问题不太重要，可以不考虑",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":306,"answer":24,"analysis":17},880426,[307,309,311,313],{"key":20,"text":308,"correct":22},"其他4个用户的水力失调度相等",{"key":24,"text":310,"correct":29},"用户4，5的水力失调度相等",{"key":27,"text":312,"correct":22},"用户1，2的水力失调度相等",{"key":31,"text":314,"correct":22},"用户1，2的水力失调度大于用户4，5的水力失调度",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":24,"analysis":17},880427,"就暖通空调领域常出现的噪声而言，NR噪声评价曲线的噪声值比A声级计测量值一般低( )。",[319,321,323,325],{"key":20,"text":320,"correct":22},"3dB",{"key":24,"text":322,"correct":29},"5dB",{"key":27,"text":324,"correct":22},"8dB",{"key":31,"text":326,"correct":22},"10dB",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":24,"analysis":17},880428,"难以实现带节能器的二次吸气制冷循环的压缩机为( )。",[331,333,335,337],{"key":20,"text":332,"correct":22},"涡旋式压缩机",{"key":24,"text":334,"correct":29},"活塞式压缩机",{"key":27,"text":336,"correct":22},"螺杆式压缩机",{"key":31,"text":338,"correct":22},"离心式压缩机",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":31,"analysis":17},880429,"下列变风量空调系统主要节能机理的描述中，哪一项是正确的？( )",[343,345,347,349],{"key":20,"text":344,"correct":22},"房间负荷变小后，房间需冷量减小，只有采用变风量系统能减少冷源设备的能耗",{"key":24,"text":346,"correct":22},"房间负荷变小后，需要冷水流量减小，因此采用变风量系统能减少水泵的能耗",{"key":27,"text":348,"correct":22},"房间负荷变小后，送风温度可提高，因此采用变风量系统能减少空气处理的能耗",{"key":31,"text":350,"correct":29},"房间负荷变小后，送风量可降低，因此采用变风量系统能减少空气输送的能耗",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":31,"analysis":17},880430,"高层民用建筑防烟楼梯间的加压送风机的全压，除计算最不利环路管道压力损失外，尚应有( )余压。",[355,357,359,361],{"key":20,"text":356,"correct":22},"30Pa",{"key":24,"text":358,"correct":22},"40Pa",{"key":27,"text":360,"correct":22},"50Pa",{"key":31,"text":362,"correct":29},"40～50Pa",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":20,"analysis":17},880431,"在考虑建筑物热工性能时，民用建筑窗墙比应为( )。",[367,369,371,373],{"key":20,"text":368,"correct":29},"建筑物外部窗户采用单层窗时，窗墙比不宜超过0.30；采用双层窗或者单框双层玻璃时，窗墙比不宜超过0.40",{"key":24,"text":370,"correct":22},"建筑物外部窗户采用单层窗时，窗墙比不宜超过0.20；采用双层窗或者单框双层玻璃时，窗墙比不宜超过0.40",{"key":27,"text":372,"correct":22},"建筑物外部窗户采用单层窗时，窗墙比不宜超过0.30；采用双层窗或者单框双层玻璃时，窗墙比不宜超过0.35",{"key":31,"text":374,"correct":22},"建筑物外部窗户采用单层窗时，窗墙比不宜超过0.20；采用双层窗或者单框双层玻璃时，窗墙比不宜超过0.30",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":24,"analysis":17},880432,"关于压缩机，以下正确的说法是( )。",[379,381,383,385],{"key":20,"text":380,"correct":22},"对于单级蒸气压缩制冷循环，采用活塞式压缩机可获得比螺杆式压缩机更低的蒸发温度",{"key":24,"text":382,"correct":29},"与螺杆式压缩机不同，离心式压缩机可设多个节能器",{"key":27,"text":384,"correct":22},"离心式压缩机的节能器数目一般与压缩级数相同",{"key":31,"text":386,"correct":22},"采用节能器可减少压缩机耗功，但对制冷量没有影响",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":24,"analysis":17},880433,"大中型冷库多采用( )系统。",[391,393,395,397],{"key":20,"text":392,"correct":22},"氟利昂直接膨胀供液制冷",{"key":24,"text":394,"correct":29},"氨泵供液制冷",{"key":27,"text":396,"correct":22},"氨重力供液制冷",{"key":31,"text":398,"correct":22},"氨直接膨胀供液制冷",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":24,"analysis":17},880434,"通风管道上设在防火分区隔墙两侧的防火阀距墙表面不应大于( )。",[403,405,407,409],{"key":20,"text":404,"correct":22},"150mm",{"key":24,"text":406,"correct":29},"200mm",{"key":27,"text":408,"correct":22},"250mm",{"key":31,"text":410,"correct":22},"300mm",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":31,"analysis":17},880435,"冷却间的冷风机可按每瓦耗冷量配( )风量。",[415,416,417,418],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":22},{"key":27,"text":17,"correct":22},{"key":31,"text":17,"correct":29},{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":31,"analysis":17},880436,"医院病房楼，建筑高度为55m，防烟楼梯间每层各有可开启外窗面积1.5㎡，前室无外窗。应采取的防排烟措施为( )。",[423,425,427,429],{"key":20,"text":424,"correct":22},"可以通过防烟楼梯间自然排烟，前室不需排烟",{"key":24,"text":426,"correct":22},"防烟楼梯间自然排烟，前室加压送风",{"key":27,"text":428,"correct":22},"防烟楼梯间和前室分别加压送风",{"key":31,"text":430,"correct":29},"防烟楼梯间加压送风，前室不送风",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":27,"analysis":17},880437,"下列哪一项小区锅炉房的设计方案是错误的？( )",[435,437,439,441],{"key":20,"text":436,"correct":22},"热水系统的循环水泵进口干管上装设高于系统静压的泄压放气管",{"key":24,"text":438,"correct":22},"补水泵的扬程不应小于补水点压力加35～50kPa富余量",{"key":27,"text":440,"correct":29},"高位膨胀水箱与热水系统连接的位置宜设在循环水泵进口干管处；高位膨胀水箱的最低水位应高于热水系统最高点1m以上",{"key":31,"text":442,"correct":22},"补水泵不宜少于2台，其中1台备用",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":27,"analysis":17},880438,"包装间、分隔间、产品整理间等人员较多的房间，对制冷系统的要求是( )。",[447,449,451,453],{"key":20,"text":448,"correct":22},"宜采用氟系统",{"key":24,"text":450,"correct":22},"应采用氟系统",{"key":27,"text":452,"correct":29},"严禁采用氨直接蒸发系统",{"key":31,"text":454,"correct":22},"严禁采用氨系统",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":27,"analysis":17},880439,"热力站加热器在选择设计时，对列管式、板式加热器传热系数的计算应乘以污垢修正系数( )。",[459,461,463,465],{"key":20,"text":460,"correct":22},"0.6～0.8",{"key":24,"text":462,"correct":22},"0.7～0.9",{"key":27,"text":464,"correct":29},"0.6～0.85",{"key":31,"text":466,"correct":22},"0.5～0.7",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":24,"analysis":17},880440,"高位水箱供水系统的加压水泵流量，应按( )确定。",[471,473,475,477],{"key":20,"text":472,"correct":22},"不应小于平均小时用水量",{"key":24,"text":474,"correct":29},"不应小于最大小时用水量",{"key":27,"text":476,"correct":22},"不应小于设计秒流量",{"key":31,"text":478,"correct":22},"不应小于最大小时用水量的1.2倍",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":31,"analysis":17},880441,"某高层建筑，采用闭式空调水循环系统，水泵、制冷机、膨胀水箱均设置在同一标高的屋面上，调试时，水泵和管道剧烈振动，且噪声很大，以至无法正常运行，试问产生该问题的原因可能是下列何项？",[483,485,487,489],{"key":20,"text":484,"correct":22},"水泵的压头过大",{"key":24,"text":486,"correct":22},"水泵的水量过大",{"key":27,"text":488,"correct":22},"膨胀水箱的底部与系统最高点的高差过大",{"key":31,"text":490,"correct":29},"膨胀水箱的底部与系统最高点的高差不够",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":20,"analysis":17},880442,"对于吸附剂中吸附气体分压力极低的气体进行再生时，应采用( )。",[495,497,499,501],{"key":20,"text":496,"correct":29},"惰性气体再生法",{"key":24,"text":498,"correct":22},"水蒸气再生法",{"key":27,"text":500,"correct":22},"热空气再生法",{"key":31,"text":502,"correct":22},"热力再生法",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":24,"analysis":17},880443,"多联机空调系统冷媒管等效长度不宜超过( )。",[507,509,511,513],{"key":20,"text":508,"correct":22},"60m",{"key":24,"text":510,"correct":29},"70m",{"key":27,"text":512,"correct":22},"80m",{"key":31,"text":514,"correct":22},"90m",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":24,"analysis":17},880444,"下列哪项不是工业卫生标准关于化学有害因素职业接触限值所采用的浓度？( )",[519,521,523,525],{"key":20,"text":520,"correct":22},"时间加权平均容许浓度",{"key":24,"text":522,"correct":29},"长时间接触容许浓度",{"key":27,"text":524,"correct":22},"短时间接触容许浓度",{"key":31,"text":526,"correct":22},"最高容许浓度",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":31,"analysis":17},880445,"在下列因素中，与室内气流组织设计相关性最小的是( )。",[531,533,535,537],{"key":20,"text":532,"correct":22},"室内温湿度要求",{"key":24,"text":534,"correct":22},"允许风速",{"key":27,"text":536,"correct":22},"室内温度梯度要求",{"key":31,"text":538,"correct":29},"气候条件",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":31,"analysis":17},880446,"下列哪种住宅建筑应设置室内消火栓系统？",[543,545,547,549],{"key":20,"text":544,"correct":22},"居住人数超过500人的两层住宅",{"key":24,"text":546,"correct":22},"居住人数超过500人的两层及两层以上住宅",{"key":27,"text":548,"correct":22},"六层及六层以上的住宅",{"key":31,"text":550,"correct":29},"七层以上的住宅",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":31,"analysis":17},880447,"下图所示低温热水地面辐射供暖加热管布置最不合理的是( )。",[555,556,557,558],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":22},{"key":27,"text":17,"correct":22},{"key":31,"text":17,"correct":29},{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":20,"analysis":17},880448,"热水采暖系统设计中有关水的自然作用压力的表述，下列哪一项是错误的？",[563,565,567,569],{"key":20,"text":564,"correct":29},"分层布置的水平单管系统，可忽略水在管道中的冷却而产生的自然作用压力影响",{"key":24,"text":566,"correct":22},"机械循环双管系统，对水在散热器中冷却而产生的自然作用压力的影响，应采取相应的技术措施",{"key":27,"text":568,"correct":22},"机械循环双管系统，对水在管道中冷却而产生的自然作用压力的影响，应采取相应的技术措施",{"key":31,"text":570,"correct":22},"机械循环单管系统，如建筑物各部分层数不同，则各立管产生的自然作用压力应计算",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":20,"analysis":17},880449,"下列关于空调设备能效比的说法中，正确的是哪一项?( )。",[575,577,579,581],{"key":20,"text":576,"correct":29},"风冷空调机组的额定制冷量增大，其COP可能会减小",{"key":24,"text":578,"correct":22},"冷水机组的额定制冷量越大，其COP越高，因此减少冷水机组台数可以达到节能效果",{"key":27,"text":580,"correct":22},"室外气温降低，会使冷水机组偏离额定工况，因此会使其COP下降",{"key":31,"text":582,"correct":22},"空调负荷率越低，冷水机组的COP越低",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":27,"analysis":17},880450,"关于围护结构附加耗热量的各种修正，下列哪一项是错误的？( )",[587,589,591,593],{"key":20,"text":588,"correct":22},"朝向修正：考虑日射影响，针对垂直外围护结构基本耗热量的修正率",{"key":24,"text":590,"correct":22},"风力附加：考虑风速变化，针对垂直外围护结构基本耗热量的修正率",{"key":27,"text":592,"correct":29},"高度附加：考虑房屋高度影响，针对垂直外围护结构基本耗热量的修正率",{"key":31,"text":594,"correct":22},"冷风渗透：考虑风压、热压作用，外门、外窗渗透风量确定后，根据室内外空气的温度差计算的耗热量",[596,599,602,605,608,611],{"id":15,"name":597,"category":7,"favorite":598},"领导干部任职前廉政法规知识测试题",92,{"id":600,"name":601,"category":7,"favorite":15},595,"建筑结构与设备",{"id":603,"name":604,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":606,"name":607,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":609,"name":610,"category":7,"favorite":8},534,"BIM工程师",{"id":612,"name":610,"category":7,"favorite":8},535]