[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-11":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":606},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,11,50,2054,[13,34,46,58,70,82,90,102,114,126,138,150,162,174,186,196,208,220,232,244,256,268,280,288,300,312,324,336,348,360,372,384,396,408,420,432,444,456,463,475,487,499,511,523,535,547,558,570,582,594],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},880351,1,"单选题","汽车库、修车库的耐火等级分为( )级。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","—",false,{"key":24,"text":25,"correct":22},"B","二",{"key":27,"text":28,"correct":29},"C","三",true,{"key":31,"text":32,"correct":22},"D","四","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},880352,"用于净化空调系统的空调机组，应具备良好的气密性，机组内静压为1kPa时，漏风率不得大于( )。",[38,40,42,44],{"key":20,"text":39,"correct":22},"0.5%",{"key":24,"text":41,"correct":29},"1%",{"key":27,"text":43,"correct":22},"1.5%",{"key":31,"text":45,"correct":22},"2%",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},880353,"一类高层民用建筑和建筑高度超过32m的二类高层建筑中经常有人停留或可燃物较多的房间，按规范要求应设机械排烟的是( )。",[50,52,54,56],{"key":20,"text":51,"correct":29},"面积超过50㎡且无法利用窗口开窗进行自然排烟的地下房间",{"key":24,"text":53,"correct":22},"面积超过50㎡的地上房间",{"key":27,"text":55,"correct":22},"面积超过100㎡的地上房间",{"key":31,"text":57,"correct":22},"面积超过50㎡的地上无窗或设固定窗的房间",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},880354,"洁净厂房疏散走廊，应设置机械防排烟设施。排烟系统的风管应采用不燃材料，其耐火极限应大于( )。",[62,64,66,68],{"key":20,"text":63,"correct":22},"0.4h",{"key":24,"text":65,"correct":29},"0.5h",{"key":27,"text":67,"correct":22},"0.6h",{"key":31,"text":69,"correct":22},"1.0h",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},880355,"当室外空气状态参数发生变化时，一次回风空调系统在冬夏季室内状态点不一样时，可以分( )区来调节。",[74,76,78,80],{"key":20,"text":75,"correct":22},"两个",{"key":24,"text":77,"correct":29},"五个",{"key":27,"text":79,"correct":22},"四个",{"key":31,"text":81,"correct":22},"三个",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},880356,"空调系统的温度调节器采用比例积分调节器时，定性描述其输出变量与时间变量的图形，以下哪一项是正确的？",[86,87,88,89],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":31,"text":33,"correct":29},{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":24,"analysis":33},880357,"立式机组中，若无设置挡水板的空间，应将高压喷雾加湿器的喷头设置为( )。",[94,96,98,100],{"key":20,"text":95,"correct":22},"顺气流方向喷射",{"key":24,"text":97,"correct":29},"逆气流方向喷射",{"key":27,"text":99,"correct":22},"垂直气流方向喷射",{"key":31,"text":101,"correct":22},"无所谓",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":20,"analysis":33},880358,"热水供暖系统正常工况下循环水泵2台并联运行，当其中1台水泵停止运行后，另1台水泵可能出现下列哪种情况？( )",[106,108,110,112],{"key":20,"text":107,"correct":29},"过载",{"key":24,"text":109,"correct":22},"流量减小，扬程增加",{"key":27,"text":111,"correct":22},"流量和扬程均增加",{"key":31,"text":113,"correct":22},"流量和扬程均减小",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":24,"analysis":33},880359,"某住宅小区设置热力站与城市集中供热管网间接连接，集中供热管网进行水力计算时，主干线的经济比摩阻建议值为( )。",[118,120,122,124],{"key":20,"text":119,"correct":22},"40～80Pa\u002Fm",{"key":24,"text":121,"correct":29},"30～70Pa\u002Fm",{"key":27,"text":123,"correct":22},"60～120Pa\u002Fm",{"key":31,"text":125,"correct":22},"60～100Pa\u002Fm",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":24,"analysis":33},880360,"设置机械排烟的地下室，应同时设送风系统，且送风量不宜小于排烟量的( )。",[130,132,134,136],{"key":20,"text":131,"correct":22},"30%",{"key":24,"text":133,"correct":29},"50%",{"key":27,"text":135,"correct":22},"60%",{"key":31,"text":137,"correct":22},"80%",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":24,"analysis":33},880361,"在采用风冷热泵冷热水机组应考虑的主要因素是下列哪一项？",[142,144,146,148],{"key":20,"text":143,"correct":22},"冬夏季室外温度和所需冷热量的大小",{"key":24,"text":145,"correct":29},"夏季室外温度、冬季室外温湿度和所需冷热量的大小",{"key":27,"text":147,"correct":22},"冬夏季室外温度和价格",{"key":31,"text":149,"correct":22},"所需冷热量的大小",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":24,"analysis":33},880362,"氨制冷系统中，通过管路与( )连接，将不凝性气体引入到空气分离器。",[154,156,158,160],{"key":20,"text":155,"correct":22},"压缩机排气侧",{"key":24,"text":157,"correct":29},"高压储液桶和冷凝器",{"key":27,"text":159,"correct":22},"压缩机吸气侧",{"key":31,"text":161,"correct":22},"低压储液桶和蒸发器",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":20,"analysis":33},880363,"洁净度等级涉及( )。",[166,168,170,172],{"key":20,"text":167,"correct":29},"悬浮粒子浓度",{"key":24,"text":169,"correct":22},"悬浮粒子物理性",{"key":27,"text":171,"correct":22},"悬浮粒子化学性",{"key":31,"text":173,"correct":22},"悬浮粒子粒径",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":24,"analysis":33},880364,"雨水管道设计采用的“设计降雨强度”( )。",[178,180,182,184],{"key":20,"text":179,"correct":22},"与重现期的长短成反比，与降雨历时的长短成正比",{"key":24,"text":181,"correct":29},"与重现期的长短成正比，与降雨历时的长短成反比",{"key":27,"text":183,"correct":22},"与重现期和降雨历时的长短均成反比",{"key":31,"text":185,"correct":22},"与重现期和降雨历时的长短均成正比",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":27,"analysis":33},880365,"关于静电除尘器的说法，正确的应是下列哪一项？",[190,192,194,195],{"key":20,"text":191,"correct":22},"粉尘比电阻与通过粉尘层的电流成正比",{"key":24,"text":193,"correct":22},"静电除尘器的效率大于98%时，除尘器的长高比应大于2.0",{"key":27,"text":33,"correct":29},{"key":31,"text":33,"correct":22},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":24,"analysis":33},880366,"洁净度等级为5级应采用( )的气流流型。",[200,202,204,206],{"key":20,"text":201,"correct":22},"垂直单向流",{"key":24,"text":203,"correct":29},"垂直或水平单向流",{"key":27,"text":205,"correct":22},"非单向流",{"key":31,"text":207,"correct":22},"混合流",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":27,"analysis":33},880367,"计算蒸汽采暖系统散热器的散热面积时，下列关于散热器内热媒平均温度的说法正确的是( )。",[212,214,216,218],{"key":20,"text":213,"correct":22},"p＞30kPa(绝对压力)时，取散热器进口蒸汽压力对应的饱和温度",{"key":24,"text":215,"correct":22},"取为100℃",{"key":27,"text":217,"correct":29},"p＞30kPa(表压)时，取散热器进口蒸汽压力对应的饱和温度",{"key":31,"text":219,"correct":22},"p＜30kPa时，取为100℃",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":27,"analysis":33},880368,"散热器表面涂料采用瓷漆与银粉漆比较，对提高散热量由大到小的次序是( )。",[224,226,228,230],{"key":20,"text":225,"correct":22},"钢制闭式散热器、钢制板型散热器、铸铁柱型散热器",{"key":24,"text":227,"correct":22},"钢制板型散热器、钢制闭式散热器、铸铁柱型散热器",{"key":27,"text":229,"correct":29},"钢制板型散热器、铸铁柱型散热器、钢制闭式散热器",{"key":31,"text":231,"correct":22},"铸铁柱型散热器、钢制闭式散热器、钢制板型散热器",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":31,"analysis":33},880369,"在下列蓄冷方式中，制冷机蓄冷工况的COP值最高的是( )。",[236,238,240,242],{"key":20,"text":237,"correct":22},"冰片滑落式蓄冷",{"key":24,"text":239,"correct":22},"封装冰蓄冷",{"key":27,"text":241,"correct":22},"内融冰式蓄冷",{"key":31,"text":243,"correct":29},"共晶盐蓄冷",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":31,"analysis":33},880370,"为保证热水管网水力平衡，所用平衡阀的安装及使用要求，下列哪一项是错误的？( )",[248,250,252,254],{"key":20,"text":249,"correct":22},"建议安装在建筑物人口的回水管道上",{"key":24,"text":251,"correct":22},"室内供暖系统环路间也可安装",{"key":27,"text":253,"correct":22},"不必再安装截止阀",{"key":31,"text":255,"correct":29},"可随意变动平衡阀的开度",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":24,"analysis":33},880371,"下列情况中不宜采用变风量空调系统的是( )。",[260,262,264,266],{"key":20,"text":261,"correct":22},"需要分别调节各房间的室内温度时",{"key":24,"text":263,"correct":29},"控制精度要求较高时",{"key":27,"text":265,"correct":22},"建设方不许可",{"key":31,"text":267,"correct":22},"同一个空调系统的各房间负荷变化较大、长期低负荷运行",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":27,"analysis":33},880372,"空调冷冻水管道敷设时，管道支架常用防腐木制瓦型管套支垫，其主要作用是下列哪一项？",[272,274,276,278],{"key":20,"text":273,"correct":22},"减弱振动的传递",{"key":24,"text":275,"correct":22},"减少管道在支吊架处的磨损",{"key":27,"text":277,"correct":29},"减少管道在支吊架处的冷桥效应",{"key":31,"text":279,"correct":22},"有利管道涨缩时，在支吊架处的位移",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":27,"analysis":33},880373,"某95℃的热水供热系统，下图中哪一种膨胀水箱与系统形式不宜采用？",[284,285,286,287],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":29},{"key":31,"text":33,"correct":22},{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":31,"analysis":33},880374,"计算低温热水地板辐射采暖热负荷时，下列哪一项是错误的？",[292,294,296,298],{"key":20,"text":293,"correct":22},"按正常热负荷乘以0.9～0.95或将室内计算温度取值降低2℃",{"key":24,"text":295,"correct":22},"房间接触土壤设地板辐射采暖时，不计入地板热损失",{"key":27,"text":297,"correct":22},"局部地面辐射采暖面积为房间总面积的70%时，需计入附加系数",{"key":31,"text":299,"correct":29},"采用分户计量地板辐射采暖时，其负荷计算可不计算户与户之间的传热负荷",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":24,"analysis":33},880375,"关于地埋管地源热泵的表述，下列哪一项是正确的？",[304,306,308,310],{"key":20,"text":305,"correct":22},"只要所承担建筑冬季的热负荷与夏季的冷负荷基本平衡，地源热泵就能保持全年总吸热量和总释热量的平衡",{"key":24,"text":307,"correct":29},"地源热泵的吸热强度过大时，即使全年总吸热量和总释热量平衡，也会出现冬季吸热量不够的情况",{"key":27,"text":309,"correct":22},"在我国夏热冬冷地区采用带辅助冷却塔的地源热泵时，运行过程不用考虑全年的总吸热量和总释热量平衡",{"key":31,"text":311,"correct":22},"在我国北方地下水流动性好的城市，大规模使用土壤源热泵不用担心全年总吸热量和总释热量平衡",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":27,"analysis":33},880376,"新建居住建筑的集中供暖系统中，目前不必做的是下列哪一项？",[316,318,320,322],{"key":20,"text":317,"correct":22},"建筑物热力人口设热量表和调节装置",{"key":24,"text":319,"correct":22},"每个房间设室温控制装置",{"key":27,"text":321,"correct":29},"每户安装分户热计量表",{"key":31,"text":323,"correct":22},"住宅的公用房间和公用空间应单独设置供暖系统",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":31,"analysis":33},880377,"甲、乙类生产厂房中下列哪一种空气循环方式是正确的？",[328,330,332,334],{"key":20,"text":329,"correct":22},"允许20%空气量循环",{"key":24,"text":331,"correct":22},"允许40%空气量循环",{"key":27,"text":333,"correct":22},"允许100%空气量循环",{"key":31,"text":335,"correct":29},"不应采用循环空气",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":24,"analysis":33},880378,"平时为汽车库，战时为人员掩蔽所的防空地下室，其通风系统做法，下列何项是错误的?( )。",[340,342,344,346],{"key":20,"text":341,"correct":22},"应设置清洁通风、滤毒通风和隔绝通风",{"key":24,"text":343,"correct":29},"应设置清洁通风和隔绝防护",{"key":27,"text":345,"correct":22},"战时应按防护单元设置独立的通风空调系统",{"key":31,"text":347,"correct":22},"穿过防护单元隔墙的通风管道，必须在规定的临战转换时限内形成隔断。",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":31,"analysis":33},880379,"在组合式空调机组各功能段的排列方式中，能充分发挥出加湿器的加湿能力的是( )。",[352,354,356,358],{"key":20,"text":353,"correct":22},"喷雾加湿器出口设置中效过滤器",{"key":24,"text":355,"correct":22},"喷雾加湿器出口设置表冷器",{"key":27,"text":357,"correct":22},"喷雾加湿器出口设置加热器",{"key":31,"text":359,"correct":29},"喷雾加湿器入口设置加热器",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":31,"analysis":33},880380,"为保证工业厂房自然通风的通风效果，下列哪项设计原则是正确的？( )",[364,366,368,370],{"key":20,"text":365,"correct":22},"按照风压作用设计",{"key":24,"text":367,"correct":22},"按照热压作用设计",{"key":27,"text":369,"correct":22},"同时考虑风压和热压",{"key":31,"text":371,"correct":29},"按照热压作用设计，并考虑避免风压可能造成的不利",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":20,"analysis":33},880381,"计算住宅给水设计秒流量的卫生器具给水当量的同时出流概率，下列哪一个概念是错误的？( )",[376,378,380,382],{"key":20,"text":377,"correct":29},"按户为单位计算确定",{"key":24,"text":379,"correct":22},"按计算管段分别确定",{"key":27,"text":381,"correct":22},"与最高日用水定额有关",{"key":31,"text":383,"correct":22},"与卫生器具给水当量有关",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":31,"analysis":33},880382,"计算围护结构传热系数时，表面换热阻的单位是( )。",[388,390,392,394],{"key":20,"text":389,"correct":22},"W\u002F(m·K)",{"key":24,"text":391,"correct":22},"W\u002F(㎡·K)",{"key":27,"text":393,"correct":22},"m·K\u002FW",{"key":31,"text":395,"correct":29},"㎡·K\u002FW",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":20,"analysis":33},880383,"下列不是事故通风系统设计准则的是( )。",[400,402,404,406],{"key":20,"text":401,"correct":29},"事故通风系统的通风量应按有害物散发量计算",{"key":24,"text":403,"correct":22},"通风量可由事故通风系统和日常通风系统共同保证",{"key":27,"text":405,"correct":22},"事故通风二般不考虑进风",{"key":31,"text":407,"correct":22},"事故排风一般不设净化措施",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":24,"analysis":33},880384,"洁净室维持正压的原理是( )。",[412,414,416,418],{"key":20,"text":413,"correct":22},"送风量大于回风量",{"key":24,"text":415,"correct":29},"送风量大于回风量和排风量之和",{"key":27,"text":417,"correct":22},"送风量大于排风量与渗透风量之和",{"key":31,"text":419,"correct":22},"送风量大于回风量、排风量和渗透风量之和",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":24,"analysis":33},880385,"空调系统冬季设计热负荷与供暖设计热负荷的关系表述中，正确的是( )。",[424,426,428,430],{"key":20,"text":425,"correct":22},"空调设计热负荷与供暖设计热负荷相等",{"key":24,"text":427,"correct":29},"空调设计热负荷大于供暖设计热负荷",{"key":27,"text":429,"correct":22},"空调设计热负荷小于供暖设计热负荷",{"key":31,"text":431,"correct":22},"不确定",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":31,"analysis":33},880386,"如果采用多孔材料(如泡沫混凝土、水泥膨胀珍珠岩等)铺设在密闭屋面中，计算传热系数时，导热系数需要乘以修正系数，是因为( )。",[436,438,440,442],{"key":20,"text":437,"correct":22},"压缩、灰浆渗入",{"key":24,"text":439,"correct":22},"灰浆渗入、吸湿",{"key":27,"text":441,"correct":22},"压缩、吸湿",{"key":31,"text":443,"correct":29},"干燥缓慢",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":31,"analysis":33},880387,"热泵系统的总吸热量是指( )。",[448,450,452,454],{"key":20,"text":449,"correct":22},"用户系统的总用冷量和热泵机组压缩机总耗功、循环水在输送过程中失去的热量并扣除水泵释放到循环水中的热量",{"key":24,"text":451,"correct":22},"用户系统的总用热量并扣除热泵机组压缩机的总耗功、循环水在输送过程中得到的热量和水泵释放到循环水中的热量",{"key":27,"text":453,"correct":22},"用户系统的总用冷量和热泵机组压缩机总耗功、循环水在输送过程中得到的热量和水泵释放到循环水中的热量",{"key":31,"text":455,"correct":29},"用户系统的总用热量并扣除热泵机组压缩机的总耗功、循环水在输送过程中失去的热量并扣除水泵释放到循环水中的热量",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":458,"answer":24,"analysis":33},880388,[459,460,461,462],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":29},{"key":27,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":20,"analysis":33},880389,"一般情况下，在建筑物的迎风面形成正压区时，风向与该平面的夹角大于( )。",[467,469,471,473],{"key":20,"text":468,"correct":29},"300",{"key":24,"text":470,"correct":22},"450",{"key":27,"text":472,"correct":22},"600",{"key":31,"text":474,"correct":22},"900",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":24,"analysis":33},880390,"有关除尘器效率、阻力的变化规律的关系，下列哪一项是错误的？( )",[479,481,483,485],{"key":20,"text":480,"correct":22},"除尘器的全效率越大，其穿透率就越小",{"key":24,"text":482,"correct":29},"旋风除尘器的效率随粉尘的分割粒径增大而提高",{"key":27,"text":484,"correct":22},"袋式除尘器的阻力随处理风量的增加而增大",{"key":31,"text":486,"correct":22},"粉尘的比电阻过大或过小，都会降低电除尘器的效率",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":20,"analysis":33},880391,"高压离心通风机，其压力范围在( )kPa。",[491,493,495,497],{"key":20,"text":492,"correct":29},"2.94～14.7",{"key":24,"text":494,"correct":22},"5～15.7",{"key":27,"text":496,"correct":22},"10～15.7",{"key":31,"text":498,"correct":22},"12～20.7",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":31,"analysis":33},880392,"暖通空调常用风机选择，下列哪一项是不正确的？( )",[503,505,507,509],{"key":20,"text":504,"correct":22},"输送有爆炸危险性的气体时，应选用防爆风机",{"key":24,"text":506,"correct":22},"机翼型叶片的离心风机效率高，适用于大型系统",{"key":27,"text":508,"correct":22},"前弯叶片离心风机构造轻，运行速度低，多用于低压系统",{"key":31,"text":510,"correct":29},"对大流量、低压头的通风系统，不宜采用轴流风机",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":20,"analysis":33},880393,"房间的热容量越小，其空调冷负荷的峰值与得热量的I峰值差( )。",[515,517,519,521],{"key":20,"text":516,"correct":29},"越小",{"key":24,"text":518,"correct":22},"越大",{"key":27,"text":520,"correct":22},"基本不变",{"key":31,"text":522,"correct":22},"不一定",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":20,"analysis":33},880394,"进行低温热水地面辐射供暖系统加热盘管水力计算时，塑料管道的当量粗糙度为( )。",[527,529,531,533],{"key":20,"text":528,"correct":29},"0.01mm",{"key":24,"text":530,"correct":22},"0.05mm",{"key":27,"text":532,"correct":22},"0.1mm",{"key":31,"text":534,"correct":22},"0.2mm",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":24,"analysis":33},880395,"机械循环热水供暖系统中的补水定压点，宜设置在循环水泵吸入端的主要原因是( )。",[539,541,543,545],{"key":20,"text":540,"correct":22},"使系统内任意点的工作压力不大于系统静压",{"key":24,"text":542,"correct":29},"使系统内任意点的工作压力不小于系统静压",{"key":27,"text":544,"correct":22},"可以降低系统的工作压力",{"key":31,"text":546,"correct":22},"可以降低补水泵的扬程",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":31,"analysis":33},880396,"关于分层空调适用条件的说法中，正确的是( )。",[551,553,554,556],{"key":20,"text":552,"correct":22},"建筑空调空间高度高于10m",{"key":24,"text":33,"correct":22},{"key":27,"text":555,"correct":22},"建筑空间仅下部区域有空调要求",{"key":31,"text":557,"correct":29},"高大空间且仅下部区域有空调要求",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":27,"analysis":33},880397,"防烟楼梯间设置的加压送风口宜( )设置一个。",[562,564,566,568],{"key":20,"text":563,"correct":22},"每层",{"key":24,"text":565,"correct":22},"每隔1～2层",{"key":27,"text":567,"correct":29},"每隔2～3层",{"key":31,"text":569,"correct":22},"每隔3层",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":20,"analysis":33},880398,"热风供暖房间长50m，宽30m，高10m，采用平行送风方式，在房间一侧墙上布置的射流数量应是( )。",[574,576,578,580],{"key":20,"text":575,"correct":29},"1股",{"key":24,"text":577,"correct":22},"2股",{"key":27,"text":579,"correct":22},"3股",{"key":31,"text":581,"correct":22},"无法确定",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":27,"analysis":33},880399,"关于通风和空调系统的矩形钢板风管截面尺寸的规定，应为下列哪一项？( )",[586,588,590,592],{"key":20,"text":587,"correct":22},"风管长、短边之比不宜大于3，最大长、短边之比不应超过6",{"key":24,"text":589,"correct":22},"风管长、短边之比不宜大于4，最大长、短边之比不应超过8",{"key":27,"text":591,"correct":29},"风管长、短边之比不宜大于4，最大长、短边之比不应超过10",{"key":31,"text":593,"correct":22},"风管长、短边之比不宜大于5，最大长、短边之比不应超过10",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":24,"analysis":33},880400,"减少局部排风罩设计排风量的方法，下列哪一项是错误的？",[598,600,602,604],{"key":20,"text":599,"correct":22},"外部吸气罩的四周加法兰",{"key":24,"text":601,"correct":29},"冷过程通风柜将吸风口设在上部",{"key":27,"text":603,"correct":22},"条缝式槽边罩将低矮截面改成高截面",{"key":31,"text":605,"correct":22},"条缝式槽边罩将等高条缝改成楔形条缝",[607,610,613,616,619,622],{"id":15,"name":608,"category":7,"favorite":609},"领导干部任职前廉政法规知识测试题",92,{"id":611,"name":612,"category":7,"favorite":15},595,"建筑结构与设备",{"id":614,"name":615,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":617,"name":618,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":620,"name":621,"category":7,"favorite":8},534,"BIM工程师",{"id":623,"name":621,"category":7,"favorite":8},535]