[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-10":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":618},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,10,50,2054,[13,34,49,62,74,82,94,106,119,132,144,156,168,180,192,205,216,228,241,253,265,277,289,301,310,322,334,346,358,369,381,393,405,417,429,438,450,462,474,486,498,510,522,534,546,558,570,582,594,606],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},880301,1,"单选题","以下关于冰蓄冷的看法，何项是错误的?( )。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","冰蓄冷系统节能量的计算方法和其他制冷节能技术的计算方法相同",true,{"key":24,"text":25,"correct":26},"B","冰蓄冷系统节能量的计算方法和其他制冷节能技术的计算方法不同",false,{"key":28,"text":29,"correct":26},"C","采用冰蓄冷系统的用户侧的实际用电量会增加",{"key":31,"text":32,"correct":26},"D","采用冰蓄冷系统能够移峰填谷，可以减少电厂的发电设备增加，同时有发电厂已有发电设备处于高效运行，广义上属于节能减排技术","",{"id":35,"libraryId":5,"type":36,"typeLabel":37,"stem":38,"options":39,"answer":48,"analysis":33},880302,2,"多选题","对于R22制冷剂，采用回热循环后，其优点有( )。",[40,42,44,46],{"key":20,"text":41,"correct":26},"制冷系数ε增加",{"key":24,"text":43,"correct":22},"保证了干压缩，有利于安全运行",{"key":28,"text":45,"correct":22},"有较大过冷度，使节流阀前液体不气化，保证热力膨胀阀的稳定工作",{"key":31,"text":47,"correct":22},"压缩机排气温度不太高","BCD",{"id":50,"libraryId":5,"type":36,"typeLabel":37,"stem":51,"options":52,"answer":61,"analysis":33},880303,"在江水源热泵空调系统设计时，正确的是( )。",[53,55,57,59],{"key":20,"text":54,"correct":22},"应进行环境影响评价",{"key":24,"text":56,"correct":22},"应通过水务和航运部门的审批",{"key":28,"text":58,"correct":22},"取水口的设置应考虑丰水期和枯水期的水位差",{"key":31,"text":60,"correct":26},"取水口应设在排水口的下游，并有一定距离","ABC",{"id":63,"libraryId":5,"type":15,"typeLabel":16,"stem":64,"options":65,"answer":20,"analysis":33},880304,"在氟利昂管道系统中，为了避免在节流孔口处产生冰塞现象，应在系统供液管上装设( )。",[66,68,70,72],{"key":20,"text":67,"correct":22},"干燥器",{"key":24,"text":69,"correct":26},"过滤器",{"key":28,"text":71,"correct":26},"贮液器",{"key":31,"text":73,"correct":26},"电磁阀",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":31,"analysis":33},880305,"下面所示氨制冷压缩机组的吸气管、排气管与总管的正确连接设计，应是哪一项？",[78,79,80,81],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":26},{"key":28,"text":33,"correct":26},{"key":31,"text":33,"correct":22},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},880306,"下列( )卫生器具不得在放水处设十字栅栏，以防粗大污物进入排水管道、引起堵塞。",[86,88,90,92],{"key":20,"text":87,"correct":26},"面盆",{"key":24,"text":89,"correct":26},"大便器",{"key":28,"text":91,"correct":26},"浴盆",{"key":31,"text":93,"correct":22},"洗手盆",{"id":95,"libraryId":5,"type":36,"typeLabel":37,"stem":96,"options":97,"answer":61,"analysis":33},880307,"下列哪些设备是冷热电三联供系统的设备？( )",[98,100,102,104],{"key":20,"text":99,"correct":22},"燃气机组",{"key":24,"text":101,"correct":22},"发电机组",{"key":28,"text":103,"correct":22},"余热锅炉",{"key":31,"text":105,"correct":26},"太阳能发电装置",{"id":107,"libraryId":5,"type":36,"typeLabel":37,"stem":108,"options":109,"answer":118,"analysis":33},880308,"下列关于R134a的性质说法正确的是( )。",[110,112,114,116],{"key":20,"text":111,"correct":22},"R134a的临界压力比R12略低，为4067kPa",{"key":24,"text":113,"correct":22},"R134a标准蒸发温度略高于R12，为-26～16℃",{"key":28,"text":115,"correct":26},"一般情况下，R134a的压力比要略小于R12，但它的排气温度比R12高",{"key":31,"text":117,"correct":22},"R134a的毒性非常低，在空气中不可燃烧，是很安全的制冷工质","ABD",{"id":120,"libraryId":5,"type":36,"typeLabel":37,"stem":121,"options":122,"answer":131,"analysis":33},880309,"某空调系统的冷水机组采用大温差工况运行，设计的供回水温度为6\u002F14℃(△t=8℃)，与常规的设计供回水温差△t=5℃(7\u002F12℃)相比，下列哪几项说法是正确的？",[123,125,127,129],{"key":20,"text":124,"correct":22},"整个系统能耗不一定低于常规温差工况运行的能耗",{"key":24,"text":126,"correct":26},"冷水机组能耗一定低于常规温差工况运行的能耗",{"key":28,"text":128,"correct":22},"采用大温差工况运行的冷水泵能耗一定低于常规温差工况运行的能耗",{"key":31,"text":130,"correct":26},"采用大温差工况运行的空调末端风机能耗一定低于常规温差工况运行的能耗","AC",{"id":133,"libraryId":5,"type":15,"typeLabel":16,"stem":134,"options":135,"answer":20,"analysis":33},880310,"热水供暖系统设1台循环水泵，若某用户开大阀门，则水泵的流量和扬程的变化为下列哪一项？( )",[136,138,140,142],{"key":20,"text":137,"correct":22},"流量增加，扬程减小",{"key":24,"text":139,"correct":26},"流量增加，扬程不变",{"key":28,"text":141,"correct":26},"流量减小，扬程增加",{"key":31,"text":143,"correct":26},"流量和扬程均增加",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":24,"analysis":33},880311,"通风系统验收时系统的总风量与设计风量允许偏差不应大于( )。",[148,150,152,154],{"key":20,"text":149,"correct":26},"8%",{"key":24,"text":151,"correct":22},"10%",{"key":28,"text":153,"correct":26},"12%",{"key":31,"text":155,"correct":26},"15%",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":31,"analysis":33},880312,"以下关闭阀门的动作温度的表述，哪一项是错误的？",[160,162,164,166],{"key":20,"text":161,"correct":26},"厨房排油烟管上的防火阀的关阀动作温度为150℃",{"key":24,"text":163,"correct":26},"卫生间排风支管上的防火阀的关阀动作温度为70℃",{"key":28,"text":165,"correct":26},"消防排烟系统中的排烟防火阀的关阀动作温度为280℃",{"key":31,"text":167,"correct":22},"正压送风系统中的加压送风阀的关阀动作温度为70℃",{"id":169,"libraryId":5,"type":36,"typeLabel":37,"stem":170,"options":171,"answer":48,"analysis":33},880313,"某建筑高度为130m的超高层民用建筑自动喷水灭火湿式系统报警阀组的配置，下列做法中哪些是错误的？( )",[172,174,176,178],{"key":20,"text":173,"correct":26},"一个报警阀组控制的喷头数不宜超过800只",{"key":24,"text":175,"correct":22},"计算一个报警阀组控制的喷头数量时，同时用作保护吊顶下方和上方空间的喷头应叠加",{"key":28,"text":177,"correct":22},"只要不超过一个报警阀组控制喷头的规定数量，同一个报警阀组所控制的楼层数可以不限",{"key":31,"text":179,"correct":22},"所有的报警阀组可以集中设置于消防给水泵房内",{"id":181,"libraryId":5,"type":36,"typeLabel":37,"stem":182,"options":183,"answer":48,"analysis":33},880314,"大量余热散发的某车间设置了全面通风系统，其吸风口的上缘离顶棚平面距离为下列哪几项时是错误的？",[184,186,188,190],{"key":20,"text":185,"correct":26},"＜0.4m",{"key":24,"text":187,"correct":22},"＜0.5rn",{"key":28,"text":189,"correct":22},"＜0.6m",{"key":31,"text":191,"correct":22},"＜0.8m",{"id":193,"libraryId":5,"type":36,"typeLabel":37,"stem":194,"options":195,"answer":204,"analysis":33},880315,"关于下进上出式氨泵供液系统，下列说法正确的是( )。",[196,198,200,202],{"key":20,"text":197,"correct":26},"充液量比上进下出式少",{"key":24,"text":199,"correct":22},"由于氨液通过氨泵输送，即使在并联支路较多的情况下也容易做到均匀配液",{"key":28,"text":201,"correct":22},"库房温度达到设定值停止供液后，由于排管中的液体不能自行排出，残留的氨液仍要继续汽化吸热，使库温继续下降，因此给准确控制库温带来一定的困难",{"key":31,"text":203,"correct":26},"在停止供液后排管中的氨液立即自行流至低压循环桶，不存在残留氨液继续汽化吸热降温的问题，因此可以较准确地控制库温，易于实现自动控制","BC",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":207,"answer":20,"analysis":33},880316,[208,210,212,214],{"key":20,"text":209,"correct":22},"2个或2个以上",{"key":24,"text":211,"correct":26},"3个或3个以上",{"key":28,"text":213,"correct":26},"3个以上",{"key":31,"text":215,"correct":26},"4个以上",{"id":217,"libraryId":5,"type":36,"typeLabel":37,"stem":218,"options":219,"answer":118,"analysis":33},880317,"与水蓄冷相比，冰蓄冷的优势是( )。",[220,222,224,226],{"key":20,"text":221,"correct":22},"蓄冷密度大",{"key":24,"text":223,"correct":22},"供水温度稳定",{"key":28,"text":225,"correct":26},"冷量损耗大",{"key":31,"text":227,"correct":22},"送风温度低",{"id":229,"libraryId":5,"type":36,"typeLabel":37,"stem":230,"options":231,"answer":240,"analysis":33},880318,"各消防给水系统一般包括( )。",[232,234,236,238],{"key":20,"text":233,"correct":22},"室外消火栓系统",{"key":24,"text":235,"correct":22},"室内消火栓系统",{"key":28,"text":237,"correct":22},"自动喷水灭火系统",{"key":31,"text":239,"correct":22},"水幕系统","ABCD",{"id":242,"libraryId":5,"type":36,"typeLabel":37,"stem":243,"options":244,"answer":118,"analysis":33},880319,"进行通风机的选择时，应遵循的原则是( )。",[245,247,249,251],{"key":20,"text":246,"correct":22},"根据通风机排送空气的性质(如清洁空气或含易燃、易爆、腐蚀性气体或粉尘等)，选用符合用途和要求的通风机类型",{"key":24,"text":248,"correct":22},"通风机的风量在通风系统风量的基础上考虑0～10%的富余系数",{"key":28,"text":250,"correct":26},"通风机的全压，应为系统管网总压损失，并取管网总压损失的15%作为附加值",{"key":31,"text":252,"correct":22},"选择通风机时，风量、风压裕量不宜过大",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":28,"analysis":33},880320,"下列哪一项旋风除尘器的结构机理及特性的论述是错误的？( )",[257,259,261,263],{"key":20,"text":258,"correct":26},"把传统的单进口改为多进口，可改进旋转气流偏心",{"key":24,"text":260,"correct":26},"旋风除尘器可适用于温度或压力较高含尘气体的除尘",{"key":28,"text":262,"correct":22},"同一型号旋风除尘器的几何尺寸，作相似放大时，除尘效率随之提高",{"key":31,"text":264,"correct":26},"随入口含尘浓度的增高，其压力损失明显下降",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":31,"analysis":33},880321,"工业场合的职业接触极限，下列哪项定义是正确的？( )",[269,271,273,275],{"key":20,"text":270,"correct":26},"劳动者在工作过程中长期反复接触，对接触者的健康不引起有害作用的容许接触水平",{"key":24,"text":272,"correct":26},"劳动者在工作过程中长期反复接触，对接触者不产生感官不适的容许接触水平",{"key":28,"text":274,"correct":26},"劳动者在工作过程中，对绝大多数接触者的健康不引起有害作用的容许接触水平",{"key":31,"text":276,"correct":22},"劳动者在工作过程中长期反复接触，对绝大多数接触者的健康不引起有害作用的容许接触水平",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":20,"analysis":33},880322,"设在地下层的直燃机房，泄爆(压)面积不得小于( )，且泄压口应避开人员密集场所。",[281,283,285,287],{"key":20,"text":282,"correct":22},"直燃机组占地(含机组前、后、左、右检修场地1m)面积的10%",{"key":24,"text":284,"correct":26},"直燃机组占地(不含机组前、后、左、右检修场地1m)面积的10%",{"key":28,"text":286,"correct":26},"直燃机组占地(含机组前、后、左、右检修场地1m)面积的15%",{"key":31,"text":288,"correct":26},"直燃机组占地(不含机组前、后、左、右检修场地1m)面积的15%",{"id":290,"libraryId":5,"type":36,"typeLabel":37,"stem":291,"options":292,"answer":61,"analysis":33},880323,"自动喷水灭火系统的设计流量同( )因素有关。",[293,295,297,299],{"key":20,"text":294,"correct":22},"喷水强度",{"key":24,"text":296,"correct":22},"建筑物性质",{"key":28,"text":298,"correct":22},"作用面积",{"key":31,"text":300,"correct":26},"喷头的形式",{"id":302,"libraryId":5,"type":36,"typeLabel":37,"stem":303,"options":304,"answer":309,"analysis":33},880324,"某排烟系统工作压力为450Pa，采用矩形排风管，下列哪几项风管漏风量值是错误的？( )",[305,306,307,308],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":26},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},"ACD",{"id":311,"libraryId":5,"type":36,"typeLabel":37,"stem":312,"options":313,"answer":61,"analysis":33},880325,"绿色建筑运营管理应建立哪些制度？( )",[314,316,318,320],{"key":20,"text":315,"correct":22},"建筑节能制度",{"key":24,"text":317,"correct":22},"节水制度",{"key":28,"text":319,"correct":22},"绿化管理制度",{"key":31,"text":321,"correct":26},"人员进出建筑(或居住小区)制度",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":20,"analysis":33},880326,"决定吸收式制冷热力过程外部条件的是3个温度，它们分别是( )。",[326,328,330,332],{"key":20,"text":327,"correct":22},"热源温度，冷却介质温度，被冷却介质温度",{"key":24,"text":329,"correct":26},"热源温度，冷却介质温度，蒸发温度",{"key":28,"text":331,"correct":26},"热源温度，冷凝温度，被冷却介质温度",{"key":31,"text":333,"correct":26},"溶液沸腾温度，冷却介质温度，被冷却介质温度",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":20,"analysis":33},880327,"前室的加压送风口应( )设一个。",[338,340,342,344],{"key":20,"text":339,"correct":22},"每层",{"key":24,"text":341,"correct":26},"每隔1～2层",{"key":28,"text":343,"correct":26},"每隔2～3层",{"key":31,"text":345,"correct":26},"每隔3层",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":28,"analysis":33},880328,"当利用管道的自然弯曲来吸收热力管道的温度变形时，自然补偿每段最大臂长的合理数值，应是下列哪一项？( )",[350,352,354,356],{"key":20,"text":351,"correct":26},"10～15m",{"key":24,"text":353,"correct":26},"15～20m",{"key":28,"text":355,"correct":22},"20～30m",{"key":31,"text":357,"correct":26},"30～40m",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":360,"answer":28,"analysis":33},880329,[361,363,365,367],{"key":20,"text":362,"correct":26},"流量和扬程均大于水泵铭牌参数",{"key":24,"text":364,"correct":26},"流量和扬程均小于水泵铭牌参数",{"key":28,"text":366,"correct":22},"流量大于、扬程小于水泵铭牌参数",{"key":31,"text":368,"correct":26},"流量小于、扬程大于水泵铭牌参数",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":24,"analysis":33},880330,"关于冷水机组的说法，下列哪一项是错误的？( )",[373,375,377,379],{"key":20,"text":374,"correct":26},"我国标准规定的蒸发冷却冷水机组额定工况的湿球温度为24℃，干球温度不限制",{"key":24,"text":376,"correct":22},"根据《冷水机组》的规定，容量为1500kW的水冷式冷水机组COP=6，此产品能源效率为1级",{"key":28,"text":378,"correct":26},"选择冷水机组时不仅要考虑额定工况下的性能，更要考虑使用频率高的时段内机组的性能",{"key":31,"text":380,"correct":26},"COP完全相同的冷水机组，当蒸发器和冷凝器的阻力不同时，供冷期系统的运行能耗也会不同",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":24,"analysis":33},880331,"建筑给水系统为使用和检修要求设置阀门，下列选项设置错误的是( )。",[385,387,389,391],{"key":20,"text":386,"correct":26},"入户管起始端",{"key":24,"text":388,"correct":22},"各种设备的配水管上",{"key":28,"text":390,"correct":26},"各立管的起始端",{"key":31,"text":392,"correct":26},"配水点大于8个的配水支管",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":24,"analysis":33},880332,"三个声源，其声压级分别是40d B、40dB和55d B，则叠加后的声压级为( )dB。",[397,399,401,403],{"key":20,"text":398,"correct":26},"45",{"key":24,"text":400,"correct":22},"55",{"key":28,"text":402,"correct":26},"50",{"key":31,"text":404,"correct":26},"100",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":31,"analysis":33},880333,"冷库选用的围护结构的总热阻Ro(㎡·℃／W)中，正确的是下列哪一项？",[409,411,413,415],{"key":20,"text":410,"correct":26},"-层为冻结物冷藏间，设计温度为-18℃；二层为冷却物冷藏间，设计温度为O℃；选楼板Ro=3.31",{"key":24,"text":412,"correct":26},"-层冷却物冷藏间，设计温度为0℃，地面隔热层采用炉渣，选地面R。=1.72",{"key":28,"text":414,"correct":26},"冻结物冷藏间，设计温度为-18℃，外墙热惰性指标D≤4，冷库所在地夏季空调室外计算干球温度为33.6℃，面积热流量为11W\u002F㎡，得外墙Ro=6.09",{"key":31,"text":416,"correct":22},"冷结物冷藏间，设计温度为-18℃，地面设在架空层上，选地面Ro=3.44",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":28,"analysis":33},880334,"当选择地下水水源热泵作为居住区的冷热源时，水源热泵系统必须确保的要求，应是下列何项?( )。",[421,423,425,427],{"key":20,"text":422,"correct":26},"回灌水的水温不高于室外空气平均温度",{"key":24,"text":424,"correct":26},"回灌水的流量等于抽水量",{"key":28,"text":426,"correct":22},"回灌水不破坏不污染所使用的水资源",{"key":31,"text":428,"correct":26},"能效比不小于分体空调机的能效比",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":31,"analysis":33},880335,"需要设置事故排风的场所，工艺不能提供有关计算资料时其事故排风量( )。",[433,435,436,437],{"key":20,"text":434,"correct":26},"无法确定",{"key":24,"text":33,"correct":26},{"key":28,"text":33,"correct":26},{"key":31,"text":33,"correct":22},{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":28,"analysis":33},880336,"某建筑物高度为80m，集中热水散热器供暖系统需要进行竖向分区设置时，以下几种方法中，哪一种是正确的？( )",[442,444,446,448],{"key":20,"text":443,"correct":26},"共用锅炉和循环水泵，在竖向各个分区环路供水管上设置减压稳压阀",{"key":24,"text":445,"correct":26},"共用锅炉，按竖向各个分区环路分别设置循环水泵",{"key":28,"text":447,"correct":22},"共用锅炉和一次循环水泵，通过换热器划分出不同压力分区的二次水循环系统",{"key":31,"text":449,"correct":26},"共用锅炉和循环水泵，设置分、集水器按竖向各个分区划分环路",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":31,"analysis":33},880337,"当烟气温度超过( )℃时，排烟防火阀应能自动关闭。",[454,456,458,460],{"key":20,"text":455,"correct":26},"300",{"key":24,"text":457,"correct":26},"250",{"key":28,"text":459,"correct":26},"200",{"key":31,"text":461,"correct":22},"280",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":28,"analysis":33},880338,"冻结白条肉的冻结间，冷却设备应采用( )。",[466,468,470,472],{"key":20,"text":467,"correct":26},"顶排管",{"key":24,"text":469,"correct":26},"墙排管",{"key":28,"text":471,"correct":22},"空气冷却器",{"key":31,"text":473,"correct":26},"搁架式冻结设备",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":24,"analysis":33},880339,"低压(450Pa)系统矩形金属风道的最大允许漏风量为5.6m3\u002F(㎡·h)，下列哪一种风道在450Pa时允许漏风量是错误的？",[478,480,482,484],{"key":20,"text":479,"correct":26},"圆形金属风道：2.8m3\u002F(㎡·h)",{"key":24,"text":481,"correct":22},"砖混凝土风道：10.2m3\u002F(n12·h)",{"key":28,"text":483,"correct":26},"复合材料风道：2.8m3\u002F(㎡·h)",{"key":31,"text":485,"correct":26},"非法兰形式的非金属风道：2.8m3\u002F(㎡·h)",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":20,"analysis":33},880340,"气调贮藏的特定气体环境是控制各种气体的含量，最普遍使用的是( )。",[490,492,494,496],{"key":20,"text":491,"correct":22},"降氧和升高二氧化碳",{"key":24,"text":493,"correct":26},"降氧和降低二氧化碳",{"key":28,"text":495,"correct":26},"升高氧和降低二氧化碳",{"key":31,"text":497,"correct":26},"降氮和升高二氧化碳",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":24,"analysis":33},880341,"布置在民用建筑内的地下室、半地下室、第一层或顶层的热水锅炉房，其额定出口热水温度不应大于下列哪一项？",[502,504,506,508],{"key":20,"text":503,"correct":26},"80℃",{"key":24,"text":505,"correct":22},"95℃",{"key":28,"text":507,"correct":26},"110℃",{"key":31,"text":509,"correct":26},"120℃",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":24,"analysis":33},880342,"某办公楼采用低温送风的空调方式，要求有良好的气流组织，且风口不能结露，但不考虑采用低温送风口，应选用下列哪一种空调系统？( )",[514,516,518,520],{"key":20,"text":515,"correct":26},"内外区为单冷型单风道变风量系统，外区加设风机盘管",{"key":24,"text":517,"correct":22},"串联式风机动力型变风量系统(内区为单冷串联式风机动力型末端，外区为再热串联式风机动力型末端)",{"key":28,"text":519,"correct":26},"并联式风机动力型变风量系统(内区为单冷型单风道末端、外区为再热并联式风机动力型末端)",{"key":31,"text":521,"correct":26},"内外区均为风机盘管",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":31,"analysis":33},880343,"居住建筑供暖系统设计时，下列哪一个计算方法是错误的？( )",[526,528,530,532],{"key":20,"text":527,"correct":26},"户内供暖设备容量计入向邻室传热引起的耗热量",{"key":24,"text":529,"correct":26},"计算户内管道时，计入向邻室传热引起的耗热量",{"key":28,"text":531,"correct":26},"计算供暖系统总管道时，不计入向邻室传热引起的耗热量",{"key":31,"text":533,"correct":22},"供暖系统总热负荷计入向邻室传热引起的耗热量",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":28,"analysis":33},880344,"燃气冷热电三联供系统，燃气轮发电机的总容量为( )。",[538,540,542,544],{"key":20,"text":539,"correct":26},"小于等于10MW",{"key":24,"text":541,"correct":26},"小于等于12MW",{"key":28,"text":543,"correct":22},"小于等于15MW",{"key":31,"text":545,"correct":26},"小于等于18MW",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":24,"analysis":33},880345,"关于辐射采暖，下列说法正确的是( )。",[550,552,554,556],{"key":20,"text":551,"correct":26},"低温辐射采暖的表面温度低于70℃",{"key":24,"text":553,"correct":22},"热水作为热媒时，温度不宜高于130℃，不宜低于110℃",{"key":28,"text":555,"correct":26},"蒸汽作为热媒时，压力不应低于300kPa",{"key":31,"text":557,"correct":26},"中温辐射采暖辐射板表面平均温度为100～150℃",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":31,"analysis":33},880346,"下列压缩式制冷机组膨胀阀的感温包安装位置，正确的是( )。",[562,564,566,568],{"key":20,"text":563,"correct":26},"冷凝器进口的制冷剂管路上",{"key":24,"text":565,"correct":26},"冷凝器出口的制冷剂管路上",{"key":28,"text":567,"correct":26},"蒸发器进口的制冷剂管路上",{"key":31,"text":569,"correct":22},"蒸发器出口的制冷剂管路上",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":28,"analysis":33},880347,"排烟系统风管钢板厚度可按风管系统类别中的( )确定。",[574,576,578,580],{"key":20,"text":575,"correct":26},"中压系统",{"key":24,"text":577,"correct":26},"低压系统",{"key":28,"text":579,"correct":22},"高压系统",{"key":31,"text":581,"correct":26},"除尘系统",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":24,"analysis":33},880348,"下列因素中，与确定建筑物内给水的最高日用水量有关的是( )。",[586,588,590,592],{"key":20,"text":587,"correct":26},"给水管网的工作压力",{"key":24,"text":589,"correct":22},"最高日用水定额",{"key":28,"text":591,"correct":26},"用水小时变化系数",{"key":31,"text":593,"correct":26},"每日用水时间",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":20,"analysis":33},880349,"哪一项参数不是确定疏水器凝结水排水量的依据？( )",[598,600,602,604],{"key":20,"text":599,"correct":22},"蒸汽系统入口的工作压力",{"key":24,"text":601,"correct":26},"疏水器前后的压差",{"key":28,"text":603,"correct":26},"疏水器选择倍率",{"key":31,"text":605,"correct":26},"需要疏水器提供的背压",{"id":607,"libraryId":5,"type":15,"typeLabel":16,"stem":608,"options":609,"answer":31,"analysis":33},880350,"某住宅小区自建燃气锅炉房供暖，设计供回水温度为85℃\u002F60℃，小区供热管网主干线的经济比摩阻宜取( )。",[610,612,614,616],{"key":20,"text":611,"correct":26},"60～120Pa\u002Fm",{"key":24,"text":613,"correct":26},"30～70Pa\u002Fm",{"key":28,"text":615,"correct":26},"100～400Pa\u002Fm",{"key":31,"text":617,"correct":22},"60～100Pa\u002Fm",[619,622,625,628,631,634],{"id":15,"name":620,"category":7,"favorite":621},"领导干部任职前廉政法规知识测试题",92,{"id":623,"name":624,"category":7,"favorite":15},595,"建筑结构与设备",{"id":626,"name":627,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":629,"name":630,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":632,"name":633,"category":7,"favorite":8},534,"BIM工程师",{"id":635,"name":633,"category":7,"favorite":8},535]