[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-1":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":614},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,1,50,2054,[13,33,45,57,69,81,93,105,113,125,137,149,161,173,185,195,207,219,231,243,255,267,279,291,303,315,327,339,351,358,370,382,394,401,416,429,442,455,467,480,493,505,516,528,540,552,564,577,590,602],{"id":14,"libraryId":5,"type":9,"typeLabel":15,"stem":16,"options":17,"answer":26,"analysis":32},879851,"单选题","不需采用乙烯乙二醇水溶液等中间冷媒的冰蓄冷方式是( )。",[18,22,25,29],{"key":19,"text":20,"correct":21},"A","冰晶式",false,{"key":23,"text":24,"correct":21},"B","盘管外结冰式",{"key":26,"text":27,"correct":28},"C","冰片滑落式",true,{"key":30,"text":31,"correct":21},"D","封装冰式","",{"id":34,"libraryId":5,"type":9,"typeLabel":15,"stem":35,"options":36,"answer":26,"analysis":32},879852,"带水封的地漏水封深度不得小于( )mm。",[37,39,41,43],{"key":19,"text":38,"correct":21},"30",{"key":23,"text":40,"correct":21},"40",{"key":26,"text":42,"correct":28},"50",{"key":30,"text":44,"correct":21},"60",{"id":46,"libraryId":5,"type":9,"typeLabel":15,"stem":47,"options":48,"answer":30,"analysis":32},879853,"冬季车间机械送风系统设置空气加热器，在热负荷计算中，下列哪一项做法正确？",[49,51,53,55],{"key":19,"text":50,"correct":21},"车间设局部排风系统每班运行时间不超过1h，可不计算其热损失",{"key":23,"text":52,"correct":21},"车间设全面通风系统稀释有害气体，采用冬季通风室外计算温度",{"key":26,"text":54,"correct":21},"车间设全面通风系统排除余湿，采用冬季采暖室外计算温度",{"key":30,"text":56,"correct":28},"车间设全面通风系统稀释低毒性有害物质，冬季采用通风室外计算温度",{"id":58,"libraryId":5,"type":9,"typeLabel":15,"stem":59,"options":60,"answer":26,"analysis":32},879854,"多层建筑内设置防烟分区的面积不宜超过( )。",[61,63,65,67],{"key":19,"text":62,"correct":21},"300㎡",{"key":23,"text":64,"correct":21},"400㎡",{"key":26,"text":66,"correct":28},"500㎡",{"key":30,"text":68,"correct":21},"600㎡",{"id":70,"libraryId":5,"type":9,"typeLabel":15,"stem":71,"options":72,"answer":19,"analysis":32},879855,"房间高度10m，跨度18m的单跨工业厂房，采用集中热风采暖系统，在厂房长度方向设一喷嘴送风，为一般平行射流，其射流的作用半径为以下哪一项？",[73,75,77,79],{"key":19,"text":74,"correct":28},"80m",{"key":23,"text":76,"correct":21},"10m",{"key":26,"text":78,"correct":21},"110m",{"key":30,"text":80,"correct":21},"120m",{"id":82,"libraryId":5,"type":9,"typeLabel":15,"stem":83,"options":84,"answer":19,"analysis":32},879856,"空调水系统设计中，下列哪一项是错误的？( )",[85,87,89,91],{"key":19,"text":86,"correct":28},"循环水泵出口管道增加平衡阀",{"key":23,"text":88,"correct":21},"主要设备与控制阀门前安装过滤器",{"key":26,"text":90,"correct":21},"并联工作的冷却塔加装平衡管",{"key":30,"text":92,"correct":21},"设置必要的固定点与补偿装置",{"id":94,"libraryId":5,"type":9,"typeLabel":15,"stem":95,"options":96,"answer":30,"analysis":32},879857,"关于制冷剂的描述，正确的是下列哪一项？",[97,99,101,103],{"key":19,"text":98,"correct":21},"天然制冷剂属于有机化合物类",{"key":23,"text":100,"correct":21},"空气不能用作制冷剂",{"key":26,"text":102,"correct":21},"制冷剂的绝热指数越低，其压缩排气温度就越高",{"key":30,"text":104,"correct":28},"制冷剂在相同工况下，一般情况是：标准沸点越低，单位容积制冷量越大",{"id":106,"libraryId":5,"type":9,"typeLabel":15,"stem":107,"options":108,"answer":23,"analysis":32},879858,"采用燃气红外线辐射供暖的厂房，燃气燃烧时耗用厂房内的空气。试问该燃烧器耗用空气量(若以厂房的换气次数计)超过下列哪一项时，就应该从室外补充供应空气？( )",[109,110,111,112],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":28},{"key":26,"text":32,"correct":21},{"key":30,"text":32,"correct":21},{"id":114,"libraryId":5,"type":9,"typeLabel":15,"stem":115,"options":116,"answer":30,"analysis":32},879859,"人防地下室平战合用一个通风系统时，粗效过滤器按( )选用。",[117,119,121,123],{"key":19,"text":118,"correct":21},"战时清洁式风量",{"key":23,"text":120,"correct":21},"战时滤毒式风量",{"key":26,"text":122,"correct":21},"平时新风量",{"key":30,"text":124,"correct":28},"最大计算新风量",{"id":126,"libraryId":5,"type":9,"typeLabel":15,"stem":127,"options":128,"answer":26,"analysis":32},879860,"下列哪项不是制冷系统中回热器的作用？( )",[129,131,133,135],{"key":19,"text":130,"correct":21},"使制冷剂在节流阀前进一步过冷",{"key":23,"text":132,"correct":21},"使制冷剂在蒸发器后进一步过热",{"key":26,"text":134,"correct":28},"可降低制冷系统的压缩比",{"key":30,"text":136,"correct":21},"可防止压缩机液击",{"id":138,"libraryId":5,"type":9,"typeLabel":15,"stem":139,"options":140,"answer":19,"analysis":32},879861,"通风系统各类防火阀的共性是( )。",[141,143,145,147],{"key":19,"text":142,"correct":28},"70℃关闭.",{"key":23,"text":144,"correct":21},"多挡风量调节",{"key":26,"text":146,"correct":21},"输出电信号",{"key":30,"text":148,"correct":21},"手拉阀索关闭",{"id":150,"libraryId":5,"type":9,"typeLabel":15,"stem":151,"options":152,"answer":23,"analysis":32},879862,"以下哪一种燃气管道不能敷设于设备层？( )",[153,155,157,159],{"key":19,"text":154,"correct":21},"天然气",{"key":23,"text":156,"correct":28},"液化石油气",{"key":26,"text":158,"correct":21},"固体燃料干馏煤气",{"key":30,"text":160,"correct":21},"固体燃料气化煤气",{"id":162,"libraryId":5,"type":9,"typeLabel":15,"stem":163,"options":164,"answer":19,"analysis":32},879863,"影响建筑物内生活用水量的最重要因素是( )。",[165,167,169,171],{"key":19,"text":166,"correct":28},"卫生设备的完善程度",{"key":23,"text":168,"correct":21},"气候条件",{"key":26,"text":170,"correct":21},"生活习惯",{"key":30,"text":172,"correct":21},"投资大小",{"id":174,"libraryId":5,"type":9,"typeLabel":15,"stem":175,"options":176,"answer":30,"analysis":32},879864,"气调保鲜间气体成分控制，一般情况下02含量为( )。",[177,179,181,183],{"key":19,"text":178,"correct":21},"0～4%",{"key":23,"text":180,"correct":21},"0～5%",{"key":26,"text":182,"correct":21},"2%～4%",{"key":30,"text":184,"correct":28},"2%～5%",{"id":186,"libraryId":5,"type":9,"typeLabel":15,"stem":187,"options":188,"answer":26,"analysis":32},879865,"每套分集水器环路(自分水器总进水管控制阀起，至集水器总出水管控制阀止)的总压力损失不宜超过( )kPa。",[189,191,193,194],{"key":19,"text":190,"correct":21},"20",{"key":23,"text":192,"correct":21},"10",{"key":26,"text":38,"correct":28},{"key":30,"text":40,"correct":21},{"id":196,"libraryId":5,"type":9,"typeLabel":15,"stem":197,"options":198,"answer":19,"analysis":32},879866,"溴化锂吸收式制冷机的性能与( )无关。",[199,201,203,205],{"key":19,"text":200,"correct":28},"蒸汽压力",{"key":23,"text":202,"correct":21},"冷却水进口温度",{"key":26,"text":204,"correct":21},"稀溶液循环量",{"key":30,"text":206,"correct":21},"系统真空度",{"id":208,"libraryId":5,"type":9,"typeLabel":15,"stem":209,"options":210,"answer":30,"analysis":32},879867,"夏季空气处理机组采用表冷器冷却空气时，“机器露点”通常选择相对湿度为90%～95%，而不是100%，试问其原因是下列哪一项？( )",[211,213,215,217],{"key":19,"text":212,"correct":21},"空气冷却到90%以上时就会发生结露",{"key":23,"text":214,"correct":21},"空调系统只需处理到90%～95%",{"key":26,"text":216,"correct":21},"采用90%～95%比采用100%更加节能",{"key":30,"text":218,"correct":28},"受表冷器接触因数的影响，无法达到100%",{"id":220,"libraryId":5,"type":9,"typeLabel":15,"stem":221,"options":222,"answer":30,"analysis":32},879868,"同时散发有害物质、余热和余湿的生产车间，其全面通风系统风量应按( )。",[223,225,227,229],{"key":19,"text":224,"correct":21},"排出有害物所需风量计算",{"key":23,"text":226,"correct":21},"排出余热和余湿所需风量计算",{"key":26,"text":228,"correct":21},"排出有害物、余热和余湿所需风量计算",{"key":30,"text":230,"correct":28},"排出有害物、余热、余湿所需风量最大值计算",{"id":232,"libraryId":5,"type":9,"typeLabel":15,"stem":233,"options":234,"answer":30,"analysis":32},879869,"提高热水网路水力稳定性的主要方法，应为下列哪一项？( )",[235,237,239,241],{"key":19,"text":236,"correct":21},"保证管网在并联节点处压降相等",{"key":23,"text":238,"correct":21},"在各热用户人口处设置静态压差平衡阀",{"key":26,"text":240,"correct":21},"相对增大网路干管压降或相对增大用户系统压降",{"key":30,"text":242,"correct":28},"相对减小网路干管压降或相对增大用户系统压降",{"id":244,"libraryId":5,"type":9,"typeLabel":15,"stem":245,"options":246,"answer":30,"analysis":32},879870,"多层住宅建筑设计时确定设置室内消防给水的原则是下列哪一项？",[247,249,251,253],{"key":19,"text":248,"correct":21},"住宅楼密度较大",{"key":23,"text":250,"correct":21},"住宅装修复杂、标准高",{"key":26,"text":252,"correct":21},"根据住宅楼的层高",{"key":30,"text":254,"correct":28},"根据住宅楼的层数",{"id":256,"libraryId":5,"type":9,"typeLabel":15,"stem":257,"options":258,"answer":26,"analysis":32},879871,"关于冰蓄冷空调系统，以下哪种说法是正确的？( )",[259,261,263,265],{"key":19,"text":260,"correct":21},"对电力移峰填谷，减少系统初投资",{"key":23,"text":262,"correct":21},"对电力移峰填谷和节能",{"key":26,"text":264,"correct":28},"对电力移峰减少系统运行电费",{"key":30,"text":266,"correct":21},"对电力移峰填谷，节能并减少运行电费",{"id":268,"libraryId":5,"type":9,"typeLabel":15,"stem":269,"options":270,"answer":23,"analysis":32},879872,"在可逆的吸收式制冷循环中，其最大热力系数等于( )。",[271,273,275,277],{"key":19,"text":272,"correct":21},"制冷量与耗热量之比",{"key":23,"text":274,"correct":28},"工作在热媒温度与环境温度之间的卡诺循环的热力效率与工作在低温热媒温度和环境温度之间的逆卡诺循环的制冷系数之积",{"key":26,"text":276,"correct":21},"工作在热媒温度与环境温度之间的卡诺循环的热力效率",{"key":30,"text":278,"correct":21},"工作在低温热媒和环境温度之间的逆卡诺循环的制冷系数",{"id":280,"libraryId":5,"type":9,"typeLabel":15,"stem":281,"options":282,"answer":30,"analysis":32},879873,"制冷循环维持一定过热度的原因是( )。",[283,285,287,289],{"key":19,"text":284,"correct":21},"提高制冷量",{"key":23,"text":286,"correct":21},"提高制冷系数",{"key":26,"text":288,"correct":21},"增大吸气比体积",{"key":30,"text":290,"correct":28},"实现压缩机的干压缩",{"id":292,"libraryId":5,"type":9,"typeLabel":15,"stem":293,"options":294,"answer":26,"analysis":32},879874,"下列关于舒适性空调送风温差的说法中，正确的是( )。",[295,297,299,301],{"key":19,"text":296,"correct":21},"送风温差越大，风机能耗越小，因此送风温差越大越好",{"key":23,"text":298,"correct":21},"送风高度小于5m时，从舒适性角度考虑，送风温差不宜大于5℃",{"key":26,"text":300,"correct":28},"采用置换通风时，送风温差不能太大",{"key":30,"text":302,"correct":21},"送风高度大于5m时，送风温差不宜小于8℃",{"id":304,"libraryId":5,"type":9,"typeLabel":15,"stem":305,"options":306,"answer":23,"analysis":32},879875,"随着入口含尘浓度的增高，旋风除尘器压力损失( )。",[307,309,311,313],{"key":19,"text":308,"correct":21},"增大",{"key":23,"text":310,"correct":28},"减小",{"key":26,"text":312,"correct":21},"基本不变",{"key":30,"text":314,"correct":21},"不一定",{"id":316,"libraryId":5,"type":9,"typeLabel":15,"stem":317,"options":318,"answer":26,"analysis":32},879876,"关于机械送风系统进风口的地点，( )是正确的。",[319,321,323,325],{"key":19,"text":320,"correct":21},"设在室外",{"key":23,"text":322,"correct":21},"设在有外窗的机房内",{"key":26,"text":324,"correct":28},"直接设在室外空气较清洁的地点，且低于排风口",{"key":30,"text":326,"correct":21},"设在屋顶上",{"id":328,"libraryId":5,"type":9,"typeLabel":15,"stem":329,"options":330,"answer":23,"analysis":32},879877,"夏热冬暖地区的办公楼采用双层中空镀膜玻璃，下列关于Low-e镀膜位置的选项中最合理的是( )。",[331,333,335,337],{"key":19,"text":332,"correct":21},"外层玻璃的外侧",{"key":23,"text":334,"correct":28},"外层玻璃的内侧",{"key":26,"text":336,"correct":21},"内层玻璃的内侧",{"key":30,"text":338,"correct":21},"内层玻璃的外侧",{"id":340,"libraryId":5,"type":9,"typeLabel":15,"stem":341,"options":342,"answer":19,"analysis":32},879878,"对现有一级泵空调水系统进行节能改造，增加变频调节功能，下列说法中错误的是( )。",[343,345,347,349],{"key":19,"text":344,"correct":28},"多台相同型号的水泵并联运行时，只要一台水泵加变频器即可",{"key":23,"text":346,"correct":21},"增加变频功能可能造成空调水系统的水力失调",{"key":26,"text":348,"correct":21},"末端装置应设置温控阀",{"key":30,"text":350,"correct":21},"仍需设置旁通管和压差控制装置",{"id":352,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":353,"answer":30,"analysis":32},879879,[354,355,356,357],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":30,"text":32,"correct":28},{"id":359,"libraryId":5,"type":9,"typeLabel":15,"stem":360,"options":361,"answer":26,"analysis":32},879880,"热网的热水供热参数为95\u002F70℃，某建筑物热力入口处热网供水管的静压高度为60m，建筑物热力入口处的供回水压差大于室内采暖系统的压力损失，该建筑物顶层供水干管相对于热力人口热网供水管的高差为58m，下列哪一项连接方式是正确的？",[362,364,366,368],{"key":19,"text":363,"correct":21},"直接连接",{"key":23,"text":365,"correct":21},"混水泵连接",{"key":26,"text":367,"correct":28},"采用板式换热器连接",{"key":30,"text":369,"correct":21},"采用减压阀连接",{"id":371,"libraryId":5,"type":9,"typeLabel":15,"stem":372,"options":373,"answer":30,"analysis":32},879881,"公共建筑节能设计时，以下哪项是进行“节能设计权衡判断”的必要条件?( )。",[374,376,378,380],{"key":19,"text":375,"correct":21},"各朝向窗墙比均为70%",{"key":23,"text":377,"correct":21},"严寒地区，建筑体型系数等于0.4",{"key":26,"text":379,"correct":21},"屋顶透明部分的面积等于屋顶总面积的20%",{"key":30,"text":381,"correct":28},"夏热冬暖地区，建筑屋面的传热系数等于1.0W／(㎡？K)",{"id":383,"libraryId":5,"type":9,"typeLabel":15,"stem":384,"options":385,"answer":30,"analysis":32},879882,"洁净室事故排风系统的手动开关设置位置最正确的是下列哪一项？( )",[386,388,390,392],{"key":19,"text":387,"correct":21},"控制室内",{"key":23,"text":389,"correct":21},"洁净室内任一位置",{"key":26,"text":391,"correct":21},"洁净室外任一位置",{"key":30,"text":393,"correct":28},"洁净室内及室外便于操作处",{"id":395,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":396,"answer":30,"analysis":32},879883,[397,398,399,400],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":30,"text":32,"correct":28},{"id":402,"libraryId":5,"type":403,"typeLabel":404,"stem":405,"options":406,"answer":415,"analysis":32},879884,2,"多选题","下列关于铝箔复合酚醛泡沫保温风管适用场合的说法中，错误的是( )。",[407,409,411,413],{"key":19,"text":408,"correct":28},"适用于大尺寸风管",{"key":23,"text":410,"correct":28},"适用于排烟风管",{"key":26,"text":412,"correct":28},"适用于洁净空调送风管",{"key":30,"text":414,"correct":21},"适用于新风送风管","ABC",{"id":417,"libraryId":5,"type":403,"typeLabel":404,"stem":418,"options":419,"answer":428,"analysis":32},879885,"载冷剂要求具有以下特性( )。",[420,422,424,426],{"key":19,"text":421,"correct":21},"比热容小，温度变化不大",{"key":23,"text":423,"correct":28},"导热系数大，在使用范围内不凝固、不气化",{"key":26,"text":425,"correct":28},"密度小，黏度低",{"key":30,"text":427,"correct":28},"无臭、无毒、不燃烧、不爆炸、化学稳定性好","BCD",{"id":430,"libraryId":5,"type":403,"typeLabel":404,"stem":431,"options":432,"answer":441,"analysis":32},879886,"制冷装置冷凝器工作时进出温差偏小，而冷凝温度与水的温差大，其原因是下列哪几项？( )",[433,435,437,439],{"key":19,"text":434,"correct":28},"冷却水流量太大",{"key":23,"text":436,"correct":21},"冷却水流量太小",{"key":26,"text":438,"correct":28},"传热效果差",{"key":30,"text":440,"correct":21},"传热效果好","AC",{"id":443,"libraryId":5,"type":403,"typeLabel":404,"stem":444,"options":445,"answer":454,"analysis":32},879887,"采用乙烯乙二醇水溶液作载冷剂时，与用水作载冷剂相比，下列变化正确的是( )。",[446,448,450,452],{"key":19,"text":447,"correct":28},"系统流量变大",{"key":23,"text":449,"correct":28},"载冷剂泵的功耗变大",{"key":26,"text":451,"correct":21},"流动阻力会减小",{"key":30,"text":453,"correct":28},"换热器内的换热面积增大","ABD",{"id":456,"libraryId":5,"type":403,"typeLabel":404,"stem":457,"options":458,"answer":415,"analysis":32},879888,"建筑热工设计时，下列哪些做法是正确的？( )",[459,461,463,465],{"key":19,"text":460,"correct":28},"北京某办公楼外墙传热系数为0.5W\u002F(㎡·K)，窗户传热系数为2.0W\u002F(㎡·K)",{"key":23,"text":462,"correct":28},"上海某办公楼外墙传热系数为1.0W\u002F(㎡·K)，南向遮阳系数为0.4",{"key":26,"text":464,"correct":28},"长春某18层住宅楼体形系数为0.25，外墙传热系数为0.5W\u002F(㎡·K)",{"key":30,"text":466,"correct":21},"南京某10层住宅楼体形系数为0.5，外墙传热系数为1.5W\u002F(㎡·K)",{"id":468,"libraryId":5,"type":403,"typeLabel":404,"stem":469,"options":470,"answer":479,"analysis":32},879889,"为保证蒸气压缩式制冷系统经济运行，应采取下列哪些做法？( )",[471,473,475,477],{"key":19,"text":472,"correct":28},"选用部分负荷条件下调节性能优异的制冷机组",{"key":23,"text":474,"correct":28},"对于制冷剂中的干燥处理，应保持有效处理",{"key":26,"text":476,"correct":21},"应采用电子膨胀阀作为节流装置",{"key":30,"text":478,"correct":21},"自动控制系统应有联锁控制功能","AB",{"id":481,"libraryId":5,"type":403,"typeLabel":404,"stem":482,"options":483,"answer":492,"analysis":32},879890,"室外供热管网管材的选择，下列哪些项是正确的？( )",[484,486,488,490],{"key":19,"text":485,"correct":28},"管径80mm，使用焊接钢管",{"key":23,"text":487,"correct":21},"管径40mm，使用无缝钢管",{"key":26,"text":489,"correct":28},"管径250mm，使用螺旋焊接钢管",{"key":30,"text":491,"correct":28},"管径150mm，使用无缝钢管","ACD",{"id":494,"libraryId":5,"type":403,"typeLabel":404,"stem":495,"options":496,"answer":415,"analysis":32},879891,"民用建筑和工业企业辅助建筑(楼梯间除外)的高度附加率，其附加于下列哪几项上是错误的？( )",[497,499,501,503],{"key":19,"text":498,"correct":28},"附加于建筑总耗热量上",{"key":23,"text":500,"correct":28},"附加于冷风渗透耗热量上",{"key":26,"text":502,"correct":28},"附加于围护结构耗热量上",{"key":30,"text":504,"correct":21},"附加于围护结构的基本耗热量和其他附加耗热量上",{"id":506,"libraryId":5,"type":403,"typeLabel":404,"stem":507,"options":508,"answer":492,"analysis":32},879892,"新风系统设计时，下列理念和做法中，哪几项是错误的？",[509,511,512,514],{"key":19,"text":510,"correct":28},"在商场空调系统中采用新风需求控制，设置定风量排风系统",{"key":23,"text":32,"correct":21},{"key":26,"text":513,"correct":28},"对办公室空调系统，必须采用新风需求控制",{"key":30,"text":515,"correct":28},"过渡季节利用新风作为空调的自然冷源，“过渡季”是指一年中的春、秋季节",{"id":517,"libraryId":5,"type":403,"typeLabel":404,"stem":518,"options":519,"answer":492,"analysis":32},879893,"关于库房的隔热，下列说法正确的是( )。",[520,522,524,526],{"key":19,"text":521,"correct":28},"冷库底层冷间设计温度低于0℃时，地面应采用防止冻胀的措施",{"key":23,"text":523,"correct":21},"冷库底层冷间设计温度等于或高于0℃时，地面可不设置隔热层",{"key":26,"text":525,"correct":28},"相邻同温冻结物冷藏间的隔墙可不设隔热层",{"key":30,"text":527,"correct":28},"冷库围护结构热惰性指标不大于4时，其隔热层外侧宜设通风层",{"id":529,"libraryId":5,"type":403,"typeLabel":404,"stem":530,"options":531,"answer":454,"analysis":32},879894,"建筑物门窗缝隙两侧的实际有效热压差与( )因素有关。",[532,534,536,538],{"key":19,"text":533,"correct":28},"中和面距地面的高度",{"key":23,"text":535,"correct":28},"形成热压的室内竖直通道内空气的密度",{"key":26,"text":537,"correct":21},"室内计算温度下空气的密度",{"key":30,"text":539,"correct":28},"建筑物内部通道的阻力状况",{"id":541,"libraryId":5,"type":403,"typeLabel":404,"stem":542,"options":543,"answer":428,"analysis":32},879895,"离心式暖风机应按下列( )原则布置。",[544,546,548,550],{"key":19,"text":545,"correct":21},"沿房间宽度方向布置，出风口距侧墙不宜小于4m",{"key":23,"text":547,"correct":28},"暖风机不应布置在房间大门附近",{"key":26,"text":549,"correct":28},"集中送风温度一般采用30～50℃，但不能高于70℃",{"key":30,"text":551,"correct":28},"送风口的出口风速一般可采用5～15m／s",{"id":553,"libraryId":5,"type":403,"typeLabel":404,"stem":554,"options":555,"answer":492,"analysis":32},879896,"采用硅胶处理湿空气，关于处理后的空气状态参数变化叙述正确的是( )。",[556,558,560,562],{"key":19,"text":557,"correct":28},"空气温度升高",{"key":23,"text":559,"correct":21},"空气温度降低",{"key":26,"text":561,"correct":28},"比焓基本不变",{"key":30,"text":563,"correct":28},"含湿量减小",{"id":565,"libraryId":5,"type":403,"typeLabel":404,"stem":566,"options":567,"answer":576,"analysis":32},879897,"下列关于空调舒适性的说法，正确的是( )。",[568,570,572,574],{"key":19,"text":569,"correct":21},"舒适性空调的目的就是使人舒适",{"key":23,"text":571,"correct":28},"夏天空凋房间室内温度降低，人体舒适度不一定提高",{"key":26,"text":573,"correct":21},"室内新风量越大越好",{"key":30,"text":575,"correct":28},"长期生活在舒适的室内环境中对人体健康不利","BD",{"id":578,"libraryId":5,"type":403,"typeLabel":404,"stem":579,"options":580,"answer":589,"analysis":32},879898,"制冷压缩机运行时，引起排气压力过高的原因，正确的是下列哪几项?( )。",[581,583,585,587],{"key":19,"text":582,"correct":28},"水冷冷凝器冷却水量不足或风冷冷凝器冷却风量不足",{"key":23,"text":584,"correct":28},"冷凝器管束表面污垢过多",{"key":26,"text":586,"correct":28},"制冷剂灌注量过多",{"key":30,"text":588,"correct":28},"制冷剂系统内有空气","ABCD",{"id":591,"libraryId":5,"type":403,"typeLabel":404,"stem":592,"options":593,"answer":428,"analysis":32},879899,"下列说法中正确的是( )。",[594,596,598,600],{"key":19,"text":595,"correct":21},"空调冷水机组不得采用氨制冷剂",{"key":23,"text":597,"correct":28},"组合式空调机组的直接蒸发制冷器不得采用氨制冷剂",{"key":26,"text":599,"correct":28},"冷库的直接蒸发制冷器可以采用氨制冷剂",{"key":30,"text":601,"correct":28},"分体空调器不得采用氨制冷剂",{"id":603,"libraryId":5,"type":403,"typeLabel":404,"stem":604,"options":605,"answer":441,"analysis":32},879900,"选择热网的管道设备附件，正确的是下列哪几项？",[606,608,610,612],{"key":19,"text":607,"correct":28},"热力网蒸汽管道应采用钢制阀门及附件",{"key":23,"text":609,"correct":21},"室外采暖计算温度低于-10℃地区热水管道地下敷设，其检查室设备附件不得采用灰铸铁制品",{"key":26,"text":611,"correct":28},"热力管道连接应采用焊接",{"key":30,"text":613,"correct":21},"热力管道公称直径不应小于32mm",[615,618,621,624,627,630],{"id":9,"name":616,"category":7,"favorite":617},"领导干部任职前廉政法规知识测试题",92,{"id":619,"name":620,"category":7,"favorite":9},595,"建筑结构与设备",{"id":622,"name":623,"category":7,"favorite":9},715,"招标采购专业知识与法律法规",{"id":625,"name":626,"category":7,"favorite":9},848,"市政方向-通用基础",{"id":628,"name":629,"category":7,"favorite":8},534,"BIM工程师",{"id":631,"name":629,"category":7,"favorite":8},535]