[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-881854":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},881854,569,2,"多选题","下列关于选择空气源热泵机组的说法，正确的是哪几项?( )。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","严寒地区，不宜作为冬季供暖采用",true,{"key":16,"text":17,"correct":18},"B","对于夏热冬冷和夏热冬暖地区，应根据冬季热负荷选型，不足冷量可由冷水机组提供",false,{"key":20,"text":21,"correct":14},"C","融霜时间总和不应超过运行周期时间的20%",{"key":23,"text":24,"correct":18},"D","供暖时的允许最低室外温度，应与冬季供暖室外计算干球温度相适应","AC","选项A正确，严寒地区冬季温度低，机组效率低；选项B错误，夏热冬冷和夏热冬暖地区空调冷负荷大于热负荷。应以冷负荷选型；根据暖规，选项C正确；选项D错误，不仅与干球温度有关、相对湿度、湿球温度等也相关。",{"id":6,"name":28,"category":29,"favorite":30},"专业知识（暖通空调专业）","建筑工程",0]