[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-880415":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},880415,569,1,"单选题","关于空调冷热源的说法中，错误的是( )。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","直燃式冷水机组比螺杆式冷水机组节能，因此燃气空调对环境的影响较小",true,{"key":16,"text":17,"correct":18},"B","在相同的设计条件下，地下水地源热泵冷热水机组的能耗可能比空气源热泵冷热水机组大",false,{"key":20,"text":21,"correct":18},"C","夏季冷负荷和冬季热负荷相差较大的建筑，不宜采用地源热泵空调系统",{"key":23,"text":24,"correct":18},"D","电蓄热锅炉的一次能源消耗量比燃煤锅炉大","直燃式冷热水机组的一次能耗通常比螺杆式冷水机组大；在地下水位很低的情况下，抽水泵的能耗大大增加，这种情况下地下水地源热泵冷热水机组的能耗有可能比风冷热泵冷热水机组大；地源热泵空调系统要求冷负荷和热负荷相差不大，否则会产生热(或冷)蓄积效应，使系统无法长期稳定运行；电锅炉的一次能源消耗比燃煤锅炉大得多，采用蓄热方式的能耗还要增加。",{"id":6,"name":27,"category":28,"favorite":29},"专业知识（暖通空调专业）","建筑工程",0]