[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-880410":3},{"question":4,"library":23},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":22},880410,569,1,"单选题","如下所示，下列楼梯间的加压送风口的设置何项是正确的？其中A为防烟楼梯间，B为防烟楼梯间，C为消防电梯前室，D为消防电梯前室。( )。",[11,15,18,20],{"key":12,"text":13,"correct":14},"A","",true,{"key":16,"text":13,"correct":17},"B",false,{"key":19,"text":13,"correct":17},"C",{"key":21,"text":13,"correct":17},"D","(1)《建规》第9.3.1条：下列场所应设置机械加压送风防烟设施：①不具备自然排烟条件的防烟楼梯间；②不具备自然排烟条件的消防电梯间前室或合用前室；③设置自然排烟设施的防烟楼梯间，其不具备自然排烟条件的前室。(2)《高规》第8.3.1条：下列部位应设置独立的机械加压送风的防烟设施：①不具备自然排烟条件的防烟楼梯间、消防电梯间前室或合用前室；②采用自然排烟措施的防烟楼梯间，其不具备自然排烟条件的前室；③封闭避难层(间)。(3)除上所述，选项B消防楼梯间不满足《建规》第9.3.1.1条和《高规》第8.3.1.1条；选项C消防电梯间前室不满足《建规》第9.3.1.2条和《高规》第8.3.1.2条；选项D电梯间不满足《建规》第9.3.1.2条和《高规》第8.3.1.2条。",{"id":6,"name":24,"category":25,"favorite":26},"专业知识（暖通空调专业）","建筑工程",0]