[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-880309":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},880309,569,2,"多选题","某空调系统的冷水机组采用大温差工况运行，设计的供回水温度为6\u002F14℃(△t=8℃)，与常规的设计供回水温差△t=5℃(7\u002F12℃)相比，下列哪几项说法是正确的？",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","整个系统能耗不一定低于常规温差工况运行的能耗",true,{"key":16,"text":17,"correct":18},"B","冷水机组能耗一定低于常规温差工况运行的能耗",false,{"key":20,"text":21,"correct":14},"C","采用大温差工况运行的冷水泵能耗一定低于常规温差工况运行的能耗",{"key":23,"text":24,"correct":18},"D","采用大温差工况运行的空调末端风机能耗一定低于常规温差工况运行的能耗","AC","",{"id":6,"name":28,"category":29,"favorite":30},"专业知识（暖通空调专业）","建筑工程",0]