[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-880020":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},880020,569,2,"多选题","对于自动控制用的两通电动调节阀，下列哪几项是正确的？( )",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","控制空气湿度时，表冷器通常应配置理想特性为等百分比的阀门",true,{"key":16,"text":17,"correct":14},"B","变流量空调水系统供回水总管之间的压差控制阀应配置理想特性为等百分比的阀门",{"key":19,"text":20,"correct":14},"C","表冷器所配置的阀门口径与表冷器的设计阻力及设计流量有关",{"key":22,"text":23,"correct":24},"D","理想的等百分比特性的阀门含义是：阀门流量与阀门开度成正比",false,"ABC","用于空调水系统压差控制的旁通阀，除了两侧有阻力较大的器件或者压差控制器的测压点就设置在旁通阀两端时，可采用直线特性的阀门以外，应选用等百分比的阀门。调节阀的口径应根据使用对象要求的流通能力，通过计算选择确定。等百分比特性的阀门流量与阀门开度不成正比。",{"id":6,"name":28,"category":29,"favorite":30},"专业知识（暖通空调专业）","建筑工程",0]