[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-879980":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},879980,569,2,"多选题","建筑高度为70m的高层塔式住宅，其剪刀楼梯间每层各有可开启外窗面积1.5㎡，但需要共用与消防电梯合用的前室，下列哪些防排烟设计做法是错误的？( )",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","如果合用前室也具有自然排烟条件，楼梯间和合用前室都可以采用自然排烟",true,{"key":16,"text":17,"correct":18},"B","如果合用前室不具有自然排烟条件，对前室和两个楼梯间分别设置加压送风系统",false,{"key":20,"text":21,"correct":14},"C","如果合用前室不具有自然排烟条件，仅对两个楼梯间分别设置机械加压送风系统",{"key":23,"text":24,"correct":14},"D","如果合用前室不具有自然排烟条件，仅对前室加压送风","ACD","“剪刀楼梯间应分别设置前室。塔式住宅确有困难时可设置一个前室，但两座楼梯应分别设置加压送风系统”。而如果与消防电梯合用的前室不具有自然排烟条件，应对与消防电梯合用的前室和楼梯间分别设置加压送风系统。",{"id":6,"name":28,"category":29,"favorite":30},"专业知识（暖通空调专业）","建筑工程",0]