[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-568-9":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":602},{"id":5,"name":6,"category":7,"favorite":8},568,"专业知识（给排水）","建筑工程",0,9,50,1213,[13,34,46,53,65,72,84,96,108,120,132,144,156,168,180,192,204,216,228,236,247,259,271,283,295,306,318,330,342,354,366,378,390,402,414,426,438,450,462,474,486,498,510,522,533,544,555,566,578,590],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},879036,1,"单选题","下述热水供应系统和管道直饮水系统管材的选择中，哪项不符合要求？( )",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","管道直饮水系统应优选薄壁不锈钢管",false,{"key":24,"text":25,"correct":22},"B","热水供应系统应优选薄壁不锈钢管",{"key":27,"text":28,"correct":29},"C","定时供应热水系统应优选塑料热水管",true,{"key":31,"text":32,"correct":22},"D","开水管道应选用许可工作温度大于100℃的金属管","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},879037,"下列关于建筑室外消防给水系统设计的叙述中，哪项错误？( )",[38,40,42,44],{"key":20,"text":39,"correct":29},"多层建筑与高层建筑的室外消火栓设置要求相同",{"key":24,"text":41,"correct":22},"多层建筑与高层建筑采用的室外消火栓规格、型号相同",{"key":27,"text":43,"correct":22},"多层建筑与高层建筑的室外消火栓均可采用低压给水系统",{"key":31,"text":45,"correct":22},"多层建筑与高层建筑的室外消防给水系统均可与生产、生活共用给水管道",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":48,"answer":24,"analysis":33},879038,[49,50,51,52],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":29},{"key":27,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":27,"analysis":33},879039,"某建筑生活给水系统供水方式为：市政供水管→贮水池→变频供水设备→系统用水点。下列关于该建筑生活给水系统设计流量计算的叙述中，哪项错误？( )",[57,59,61,63],{"key":20,"text":58,"correct":22},"贮水池进水管设计流量可按该建筑最高日最大时用水量计算",{"key":24,"text":60,"correct":22},"贮水池进水管设计流量可按该建筑最高日平均时用水量计算",{"key":27,"text":62,"correct":29},"变频供水设备的设计流量应按该建筑最高日最大时用水量计算",{"key":31,"text":64,"correct":22},"变频供水设备的设计流量应按该建筑生活给水系统设计秒流量计算",{"id":66,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":67,"answer":20,"analysis":33},879040,[68,69,70,71],{"key":20,"text":33,"correct":29},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":73,"libraryId":5,"type":15,"typeLabel":16,"stem":74,"options":75,"answer":27,"analysis":33},879041,"建筑排水系统中设有通气管系的塑料排水立管，其底部管径宜放大一号的主要原因是下面哪一项？( )",[76,78,80,82],{"key":20,"text":77,"correct":22},"防止管道堵塞",{"key":24,"text":79,"correct":22},"便于与横干管连接",{"key":27,"text":81,"correct":29},"缓解底部过高的压力",{"key":31,"text":83,"correct":22},"减小温度变化对管道的影响",{"id":85,"libraryId":5,"type":15,"typeLabel":16,"stem":86,"options":87,"answer":27,"analysis":33},879042,"下列关于建筑生活排水系统通气管的说法，哪项错误？( )",[88,90,92,94],{"key":20,"text":89,"correct":22},"伸顶通气管管径不应小于排水立管管径",{"key":24,"text":91,"correct":22},"通气管可平衡排水管道中的正压和负压",{"key":27,"text":93,"correct":29},"通气管最小管径不应小于DN40",{"key":31,"text":95,"correct":22},"吸气阀不能代替通气管",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":24,"analysis":33},879043,"建筑生活排水立管气压最大值标准应为下列哪项？( )",[100,102,104,106],{"key":20,"text":101,"correct":22},"±300Pa",{"key":24,"text":103,"correct":29},"±400Pa",{"key":27,"text":105,"correct":22},"±450Pa",{"key":31,"text":107,"correct":22},"±500Pa",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":24,"analysis":33},879044,"下列排水方式中，哪项错误？( )",[112,114,116,118],{"key":20,"text":113,"correct":22},"某办公楼1～12层的卫生间设环形通气排水系统，首层卫生间排水接入排水立管",{"key":24,"text":115,"correct":29},"生活饮用水二次供水贮水池设于首层，水池溢流管(DN150)接入室外排水检查井，其管内底高于检查井设计水位300mm",{"key":27,"text":117,"correct":22},"住宅的厨房设置专用排水立管，各层厨房洗涤盆排水支管与排水立管相连接",{"key":31,"text":119,"correct":22},"办公楼职工餐厅厨房地面设排水明沟，洗碗机、洗肉池的排水排入该明沟",{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":20,"analysis":33},879045,"我国把消火栓人工灭火系统而不是自动喷水灭火系统作为高层民用建筑最基本的灭火设备，其主要理由为下列哪项？( )",[124,126,128,130],{"key":20,"text":125,"correct":29},"消火栓灭火系统工程造价较低",{"key":24,"text":127,"correct":22},"人工灭火比自动灭火可减少人员伤亡",{"key":27,"text":129,"correct":22},"人工灭火系统的日常维护费用比自动灭火系统的低",{"key":31,"text":131,"correct":22},"消火栓系统的灭火、控火效果比自动喷水灭火系统好",{"id":133,"libraryId":5,"type":15,"typeLabel":16,"stem":134,"options":135,"answer":20,"analysis":33},879046,"湿式报警阀在自动喷水灭火系统中的作用，是下列哪项？( )",[136,138,140,142],{"key":20,"text":137,"correct":29},"接通或关断报警水流和防止水倒流",{"key":24,"text":139,"correct":22},"接通或关断向配水管道供水",{"key":27,"text":141,"correct":22},"检测自动报警系统的可靠性",{"key":31,"text":143,"correct":22},"控制喷头数",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":24,"analysis":33},879047,"下列关于建筑卫生器具排水当量的说法中，哪项正确？( )",[148,150,152,154],{"key":20,"text":149,"correct":22},"一个排水当量的排水流量相当于一个给水当量额定流量",{"key":24,"text":151,"correct":29},"一个排水当量的排水流量相当于一个给水当量额定流量的1.65倍",{"key":27,"text":153,"correct":22},"一个排水当量的排水流量相当于一个给水当量额定流量的2.4倍",{"key":31,"text":155,"correct":22},"卫生器具排水当量的排水流量不能折算为其给水当量的额定流量",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":20,"analysis":33},879048,"下列对水加热设备选择的叙述何项是错误的？( )",[160,162,164,166],{"key":20,"text":161,"correct":29},"用水较均匀、热媒供应充足时，一般可选用贮热容积大的导流型容积式水加热器",{"key":24,"text":163,"correct":22},"医院建筑不得采用有滞水区的容积式水加热器",{"key":27,"text":165,"correct":22},"需同时供给多个卫生器具热水时，宜选用带贮热容积的水加热设备",{"key":31,"text":167,"correct":22},"采用配容积式或半容积式水加热器的热水机组，当设置在建筑物的地下室时，可利用冷水系统压力，无须另设热水加压系统",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":27,"analysis":33},879049,"下列关于屋面雨水排水系统设计的叙述中，哪项不正确？( )",[172,174,176,178],{"key":20,"text":173,"correct":22},"满管压力流悬吊管的设计流速一般大于重力流的设计流速",{"key":24,"text":175,"correct":22},"满管压力流埋地排出管的设计流速一般低于其立管的设计流速",{"key":27,"text":177,"correct":29},"立管的管径不应小于上游横管管径",{"key":31,"text":179,"correct":22},"重力流埋地管可按满流设计",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":20,"analysis":33},879050,"下列关于自动喷水灭火系统设置的叙述中，哪项不正确？( )",[184,186,188,190],{"key":20,"text":185,"correct":29},"配水干管必须环状布置",{"key":24,"text":187,"correct":22},"减压阀不应设在报警阀下游",{"key":27,"text":189,"correct":22},"高位消防水箱的消防出水管上应设止回阀",{"key":31,"text":191,"correct":22},"局部应用系统在一定条件下可与室内消火栓竖管连接",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":31,"analysis":33},879051,"关于热媒耗量，下列哪项是正确的？( )",[196,198,200,202],{"key":20,"text":197,"correct":22},"热媒耗量是确定热水配水管网管径的依据",{"key":24,"text":199,"correct":22},"热媒耗量与设计小时耗热量数值大小无关",{"key":27,"text":201,"correct":22},"热媒管道热损失附加系数与系统耗热量有关",{"key":31,"text":203,"correct":29},"燃油机组热媒耗量与加热设备效率有关",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":24,"analysis":33},879052,"下列有关建筑重力流排水系统的立管、横管通过不同流量管内流态变化的叙述中，哪一项是不正确的？( )",[208,210,212,214],{"key":20,"text":209,"correct":22},"通过立管的流量小于该管的设计流量时，管内呈非满流状态",{"key":24,"text":211,"correct":29},"进过立管的流量等于该管的设计流量时，管内呈满流状态",{"key":27,"text":213,"correct":22},"通过横干管的流量小于该管的设计流量时，管内呈非满流状态",{"key":31,"text":215,"correct":22},"通过横干管的流量等于该管的设计流量时，管内仍呈非满流状态",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":24,"analysis":33},879053,"海南某温泉度假酒店，采用城市自来水供应酒店集中生活热水。需加热至55℃供水。当地无城市热力管网，电力供应有保证。本着节能、环保、安全的原则合理选择热源。下列可作为优选项热源是哪一项？( )",[220,222,224,226],{"key":20,"text":221,"correct":22},"电",{"key":24,"text":223,"correct":29},"太阳能",{"key":27,"text":225,"correct":22},"自备燃油锅炉",{"key":31,"text":227,"correct":22},"空气源热泵",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":20,"analysis":33},879054,"下列关于高层建筑生活热水供应系统减压阀设置的图示中，哪个是错误的？( )",[232,233,234,235],{"key":20,"text":33,"correct":29},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":20,"analysis":33},879055,"某五星级宾馆集中生活热水供应系统的热水水质如下，哪项不符合要求？( )",[240,242,244,246],{"key":20,"text":241,"correct":29},"铝离子的浓度不超过0.3mg\u002FL",{"key":24,"text":243,"correct":22},"甲醛的浓度为0.75mg\u002FL",{"key":27,"text":245,"correct":22},"溶解氧的浓度为3mg\u002FL",{"key":31,"text":33,"correct":22},{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":24,"analysis":33},879056,"下列有关生活热水供应系统热水水温的叙述中，何项是错误的？( )",[251,253,255,257],{"key":20,"text":252,"correct":22},"水加热器的出水温度与配水点最低水温的温度差不得大于10℃",{"key":24,"text":254,"correct":29},"冷热水混合时，应以系统最高供应热水水温、冷水水温和混合后使用水温求出冷、热水量的比例",{"key":27,"text":256,"correct":22},"在控制加热设备出口最高水温的前提下，适当提高其出水水温可达到增大蓄热量、减少热水供应量的效果",{"key":31,"text":258,"correct":22},"降低加热设备出水与配水点的水温差，能起到减缓腐蚀和延缓结垢的作用",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":27,"analysis":33},879057,"下列关于自动喷水灭火系统设计原则的叙述中，哪项错误？( )",[263,265,267,269],{"key":20,"text":264,"correct":22},"雨淋系统中雨淋阀自动启动后，该阀所控制的喷头全部喷水",{"key":24,"text":266,"correct":22},"湿式系统中的喷头要能有效地探测初期火灾",{"key":27,"text":268,"correct":29},"预作用系统应在开放一只喷头后自动启动",{"key":31,"text":270,"correct":22},"在灭火进程中，作用面积内开放的喷头，应在规定的时间内按设计选定的喷水强度持续喷水",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":27,"analysis":33},879058,"下列有关建筑物内生活排水系统设计的说法中，哪项错误？( )",[275,277,279,281],{"key":20,"text":276,"correct":22},"排水立管应设置通气设施",{"key":24,"text":278,"correct":22},"重力流排出管最小管径为DN50",{"key":27,"text":280,"correct":29},"住宅卫生间采用同层排水方式时，卫生间应降板",{"key":31,"text":282,"correct":22},"阳台雨水地漏采用无水封(且不设存水弯)地漏",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":24,"analysis":33},879059,"下述关于高层建筑热水供应系统采用减压阀分区供水时，减压阀的管径及设置要求中，哪项不正确？( )",[287,289,291,293],{"key":20,"text":288,"correct":22},"高、低两区各有独立的加热设备及循环泵时，减压阀可设在高、低区的热水供水立管或配水支管上",{"key":24,"text":290,"correct":29},"高、低两区使用同一热水加热设备及循环泵时，减压阀可设在低区的热水供水立管上",{"key":27,"text":292,"correct":22},"高、低两区使用同一热水加热设备及循环泵，当只考虑热水干管和热水立管循环时，减压阀应设在各区的配水支管上",{"key":31,"text":294,"correct":22},"减压阀的公称直径宜与管道管径相同",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":297,"answer":31,"analysis":33},879060,[298,300,302,304],{"key":20,"text":299,"correct":22},"Q",{"key":24,"text":301,"correct":22},"85%Q",{"key":27,"text":303,"correct":22},"90%Q",{"key":31,"text":305,"correct":29},"95%Q",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":24,"analysis":33},879061,"某建筑高度为45m的办公楼设有2层地下室(作为停车库和设备机房)。则该地下室车库部位手提式灭火器的保护距离不应超过下列哪项数值？( )",[310,312,314,316],{"key":20,"text":311,"correct":22},"9m",{"key":24,"text":313,"correct":29},"12m",{"key":27,"text":315,"correct":22},"15m",{"key":31,"text":317,"correct":22},"20m",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":31,"analysis":33},879062,"下列有关小区绿地喷灌的建筑雨水供水系统设计要求的叙述中，哪项错误？( )",[322,324,326,328],{"key":20,"text":323,"correct":22},"供水管道上应装设水表计量",{"key":24,"text":325,"correct":22},"供水管道上不得装设取水龙头",{"key":27,"text":327,"correct":22},"供水管材不得采用非镀锌钢管",{"key":31,"text":329,"correct":29},"自来水补水管口进入雨水蓄水池内补水时，应采取空气隔断措施",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":20,"analysis":33},879063,"下列关于建筑排水系统检查口设置的做法中，哪项不正确？( )",[334,336,338,340],{"key":20,"text":335,"correct":29},"某6层建筑(每层设有卫生器具)的排水立管分别在1、3、5层设置了检查口",{"key":24,"text":337,"correct":22},"排水立管的偏转处设有乙字弯",{"key":27,"text":339,"correct":22},"在水流偏转角为60。的排水横管上设置了检查口",{"key":31,"text":341,"correct":22},"排水立管上检查口距所在楼面1.0m以上，并高于该层卫生器具上边缘0.15m",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":24,"analysis":33},879064,"以下有关中水水源的叙述中，哪项是不正确的？( )",[346,348,350,352],{"key":20,"text":347,"correct":22},"优质杂排水、杂排水、生活排水均可作为中水水源",{"key":24,"text":349,"correct":29},"杂排水即为民用建筑中除粪便污水、厨房排水外的各种排水",{"key":27,"text":351,"correct":22},"优质杂排水即为杂排水中污染程度较低的排水",{"key":31,"text":353,"correct":22},"生活排水中的有机物和悬浮物的浓度高于杂排水",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":27,"analysis":33},879065,"某建筑顶层有5根排水立管的通气管需汇合后伸到屋顶，排水立管分别是2根75mm和3根100mm。汇合通气管的最小公称管径应为下列哪项？( )",[358,360,362,364],{"key":20,"text":359,"correct":22},"100mm",{"key":24,"text":361,"correct":22},"125mm",{"key":27,"text":363,"correct":29},"150mm",{"key":31,"text":365,"correct":22},"200mm",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":27,"analysis":33},879066,"下列有关热水供应方式的叙述中哪项是错误的？( )",[370,372,374,376],{"key":20,"text":371,"correct":22},"干管循环方式是指仅热水干管设置循环管道，保持热水循环",{"key":24,"text":373,"correct":22},"开式热水供水方式是在所有配水点关闭后，系统内的水仍与大气相通",{"key":27,"text":375,"correct":29},"机械循环方式是通过循环水泵的工作在热水管网内补充一定的循环流量以保证系统热水供应",{"key":31,"text":377,"correct":22},"闭式热水供应方式供水的水压稳定性和安全可靠性较差",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":24,"analysis":33},879067,"下列哪项车间的生产火灾危险性属丙类？( )",[382,384,386,388],{"key":20,"text":383,"correct":22},"金属烧焊车间",{"key":24,"text":385,"correct":29},"塑料制品车间",{"key":27,"text":387,"correct":22},"水泥制品车间",{"key":31,"text":389,"correct":22},"燃气热水炉间",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":20,"analysis":33},879068,"某建筑同一场所按C类火灾配置的下列两种类型灭火器，哪项不正确？( )",[394,396,398,400],{"key":20,"text":395,"correct":29},"磷酸铵盐干粉与碳酸氢钠干粉型灭火器",{"key":24,"text":397,"correct":22},"碳酸氢钠干粉与二氧化碳灭火器",{"key":27,"text":399,"correct":22},"碳酸氢钠干粉与卤代烷灭火器",{"key":31,"text":401,"correct":22},"二氧化碳与卤代烷灭火器",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":24,"analysis":33},879069,"住宅集中生活热水供应系统配水点最低水温(℃)不应低于下列哪项？( )",[406,408,410,412],{"key":20,"text":407,"correct":22},"40",{"key":24,"text":409,"correct":29},"45",{"key":27,"text":411,"correct":22},"50",{"key":31,"text":413,"correct":22},"55",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":31,"analysis":33},879070,"某净空高度10.8m的自选商场，货物堆放高度为4.5m。设计自动喷水灭火系统时，其作用面积应采用下列哪项？( )",[418,420,422,424],{"key":20,"text":419,"correct":22},"160㎡",{"key":24,"text":421,"correct":22},"200㎡",{"key":27,"text":423,"correct":22},"260㎡",{"key":31,"text":425,"correct":29},"300㎡",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":31,"analysis":33},879071,"末端试水装置在自动喷水灭火系统中的作用是下列哪种？( )",[430,432,434,436],{"key":20,"text":431,"correct":22},"用于系统调试",{"key":24,"text":433,"correct":22},"用于系统供水",{"key":27,"text":435,"correct":22},"用于检测最不利喷头的流量",{"key":31,"text":437,"correct":29},"用于检测自动喷水灭火系统的可靠性",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":24,"analysis":33},879072,"某小区占地面积为12000㎡，其中混凝土路面2400㎡，绿地7200㎡，块石路面1200㎡，非铺砌路面1200㎡，则该小区地面综合径流系数应为下列哪项？( )",[442,444,446,448],{"key":20,"text":443,"correct":22},"0.15",{"key":24,"text":445,"correct":29},"0.36",{"key":27,"text":447,"correct":22},"0.49",{"key":31,"text":449,"correct":22},"0.90",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":27,"analysis":33},879073,"一座单层摄影棚，净空高度为7.8m，建筑面积10400㎡，其中自动喷水灭火湿式系统保护面积为2600㎡，布置闭式洒水喷头300个；雨淋系统保护面积为7800㎡，布置开式洒水喷头890个，则按规定应设置多少组雨淋阀？( )",[454,456,458,460],{"key":20,"text":455,"correct":22},"2组",{"key":24,"text":457,"correct":22},"3组",{"key":27,"text":459,"correct":29},"30组",{"key":31,"text":461,"correct":22},"40组",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":27,"analysis":33},879074,"下列关于高层建筑热水供应系统设计的叙述中，有几项是错误的？①高层建筑的集中热水供应系统应竖向分区供水②高层建筑的集中热水供应系统不应采用塑料给水管③高层建筑的热水用水定额应高于多层建筑的用水定额④建筑高度超过100m的高层建筑的集中热水供应系统宜采用垂直串联供水方式( )",[466,468,470,472],{"key":20,"text":467,"correct":22},"1项",{"key":24,"text":469,"correct":22},"2项",{"key":27,"text":471,"correct":29},"3项",{"key":31,"text":473,"correct":22},"4项",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":24,"analysis":33},879075,"某病房楼采用蒸汽制备生活热水，热水制备能力按最大小时用水量60℃配置。经计算，所需要的热水调节容积为最大小时用水量的50%。则下列水加热器(两台，型号、规格相同)的设置中，哪项正确(注：下列水加热器的贮热量为单台的容量)？( )",[478,480,482,484],{"key":20,"text":479,"correct":22},"选用导流型容积式水加热器，贮热量为30min最大小时耗热量",{"key":24,"text":481,"correct":29},"选用半容积式水加热器，贮热量为20min最大小时耗热量",{"key":27,"text":483,"correct":22},"选用容积式水加热器，贮热量为45min最大小时耗热量",{"key":31,"text":485,"correct":22},"选用半即热式水加热器，贮热量为10min最大小时耗热量",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":31,"analysis":33},879076,"关于自动喷水灭火系统湿式和干式两种报警阀功能的叙述中，何项是错误的？( )",[490,492,494,496],{"key":20,"text":491,"correct":22},"均具有喷头动作后报警水流驱动水力警铃和压力开关报警的功能",{"key":24,"text":493,"correct":22},"均具有防止系统水流倒流至水源的止回功能",{"key":27,"text":495,"correct":22},"均具有接通或关断报警水流的功能",{"key":31,"text":497,"correct":29},"均具有延迟误报警的功能",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":27,"analysis":33},879077,"以下关于热源，热媒的叙述中，哪项不正确？( )",[502,504,506,508],{"key":20,"text":503,"correct":22},"城市热力管网的热媒温度当冬季高夏季低时，要按夏季温度计算换热器的换热面积(冷水采用地下水)",{"key":24,"text":505,"correct":22},"如果城市供热的热力管网每年有约半个月的检修期中断运行，则该热力管网不能作为热源",{"key":27,"text":507,"correct":29},"当热交换器设于超高层建筑的避难层时，城市热力管网热媒一般需要换热，换热产生的水再作为热媒供向避难层换热间",{"key":31,"text":509,"correct":22},"空气源热泵用作生活热水的热源适用于夏热冬暖地区",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":27,"analysis":33},879078,"用蒸汽作热媒阀间接加热的水加热器，下列关于疏水器安装的叙述，哪项是错误的？( )",[514,516,518,520],{"key":20,"text":515,"correct":22},"蒸汽立管最低处宜设疏水管",{"key":24,"text":517,"correct":22},"蒸汽管下凹处的下部宜设疏水器",{"key":27,"text":519,"correct":29},"多台水加热器可在凝结水回水总管上统一设置疏水器",{"key":31,"text":521,"correct":22},"当水加热器的换热能保证凝结水回水温度小于等于80℃，其凝结水回水管上可不装疏水器",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":524,"answer":20,"analysis":33},879079,[525,527,529,531],{"key":20,"text":526,"correct":29},"高压系统",{"key":24,"text":528,"correct":22},"临时高压系统",{"key":27,"text":530,"correct":22},"低压系统",{"key":31,"text":532,"correct":22},"临时低压系统",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":535,"answer":27,"analysis":33},879080,[536,538,540,542],{"key":20,"text":537,"correct":22},"31587kW",{"key":24,"text":539,"correct":22},"31754kW",{"key":27,"text":541,"correct":29},"32033kW",{"key":31,"text":543,"correct":22},"32300kW",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":546,"answer":31,"analysis":33},879081,[547,549,551,553],{"key":20,"text":548,"correct":22},"甲50mm，乙50mm",{"key":24,"text":550,"correct":22},"甲25mm，乙40mm",{"key":27,"text":552,"correct":22},"甲33mm，乙50mm",{"key":31,"text":554,"correct":29},"甲32mm，乙50mm",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":557,"answer":27,"analysis":33},879082,[558,560,562,564],{"key":20,"text":559,"correct":22},"1110000kJ\u002Fh",{"key":24,"text":561,"correct":22},"2910000kJ\u002Fh",{"key":27,"text":563,"correct":29},"2970000kJ\u002Fh",{"key":31,"text":565,"correct":22},"3140000kJ\u002Fh",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":27,"analysis":33},879083,"下述哪一项论述不符合饮用净水的设计要求？( )",[570,572,574,576],{"key":20,"text":571,"correct":22},"饮用净水水嘴用软管连接且水嘴不固定时，应设置防回流阀",{"key":24,"text":573,"correct":22},"饮用净水水嘴在满足使用要求的前提下，应选用额定流量小的专用水嘴",{"key":27,"text":575,"correct":29},"计算饮用净水贮水池(箱)容积时，调节水量、调节系数取值均应偏大些，以保证供水安全",{"key":31,"text":577,"correct":22},"循环回水须经过消毒处理回流至净水箱",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":24,"analysis":33},879084,"室内消火栓管网的设计，下列哪条不符合现行《消防给水及消火栓系统技术规范》的要求？( )",[582,584,586,588],{"key":20,"text":583,"correct":22},"与供水横干管连接的每根立管上设置阀门",{"key":24,"text":585,"correct":29},"多高层公共建筑各层均可按照关闭同层不超过5个消火栓设置管道和阀门",{"key":27,"text":587,"correct":22},"立管的最小流量10L\u002FS，经计算立管管径DN80即可，实际取DN100",{"key":31,"text":589,"correct":22},"除特殊情况外，室内消火栓系统管网均应布置成环形",{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":20,"analysis":33},879085,"下述有关热水供应系统的选择及设置要求中，哪项是不正确的？( )",[594,596,598,600],{"key":20,"text":595,"correct":29},"汽～水混合加热设备宜用于闭式热水供应系统",{"key":24,"text":597,"correct":22},"设置淋浴器的公共浴室宜采用开式热水供应系统",{"key":27,"text":599,"correct":22},"公共浴池的热水供应系统应设置循环水处理和消毒设备",{"key":31,"text":601,"correct":22},"单管热水供应系统应设置水温稳定的技术措施",[603,606,609,612,615,618],{"id":15,"name":604,"category":7,"favorite":605},"领导干部任职前廉政法规知识测试题",92,{"id":607,"name":608,"category":7,"favorite":15},595,"建筑结构与设备",{"id":610,"name":611,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":613,"name":614,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":616,"name":617,"category":7,"favorite":8},534,"BIM工程师",{"id":619,"name":617,"category":7,"favorite":8},535]