[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-568-8":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":595},{"id":5,"name":6,"category":7,"favorite":8},568,"专业知识（给排水）","建筑工程",0,8,50,1213,[13,34,46,53,65,77,89,101,113,120,132,144,156,168,180,192,204,216,228,240,252,264,275,287,299,311,323,335,347,355,367,379,391,403,410,421,433,445,457,469,480,492,504,516,528,540,552,559,571,583],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},878985,1,"单选题","下述某工程卫生间先用的给水管及其敷设方式中，哪一项是正确合理的？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","选用PP-R聚丙烯管，热熔连接，敷设在结构板内",false,{"key":24,"text":25,"correct":26},"B","选用PP-R聚丙烯管，热熔连接，敷设在地面找平层内",true,{"key":28,"text":29,"correct":22},"C","选用PP-R聚丙烯管，热熔连接，靠墙、顶板明设",{"key":31,"text":32,"correct":22},"D","选用薄壁不锈钢管，卡环式连接，敷设在找平层内","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},878986,"给水管道的下列哪个部位可不设置阀门？( )",[38,40,42,44],{"key":20,"text":39,"correct":22},"居住小区给水管道从市政给水管道的引入管段上",{"key":24,"text":41,"correct":22},"人户管、水表前",{"key":28,"text":43,"correct":22},"从小区给水干管上接出的接户管起端",{"key":31,"text":45,"correct":26},"配水点在3个及3个以上的配水支管上",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":48,"answer":31,"analysis":33},878987,[49,50,51,52],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":26},{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":20,"analysis":33},878988,"下列关于通气管和水封的叙述中，哪项错误？( )",[57,59,61,63],{"key":20,"text":58,"correct":26},"虹吸式坐便器利用自虹吸排除污水，因此自虹吸不会破坏水封",{"key":24,"text":60,"correct":22},"结合通气管宜每层与排水立管和专用通气立管连接",{"key":28,"text":62,"correct":22},"活动机械密封会产生漏气，不能替代水封",{"key":31,"text":64,"correct":22},"通气管道不能确保存水弯水封安全",{"id":66,"libraryId":5,"type":15,"typeLabel":16,"stem":67,"options":68,"answer":28,"analysis":33},878989,"下列关于通气管设计的说法中，哪项错误？( )",[69,71,73,75],{"key":20,"text":70,"correct":22},"结合通气管与排水立管和通气立管应采用斜三通连接",{"key":24,"text":72,"correct":22},"环形通气管水平段应按不小于1%的上升坡度与副通气立管相接",{"key":28,"text":74,"correct":26},"当污、废排水立管合用一根通气立管时，应全部采用H管件替代结合通气管",{"key":31,"text":76,"correct":22},"当两根排水立管合用一根通气立管(长度＞50m)时，通气立管管径应与管径最大的排水立管相同",{"id":78,"libraryId":5,"type":15,"typeLabel":16,"stem":79,"options":80,"answer":20,"analysis":33},878990,"某公共建筑，在用水高峰时，市政管网的水压不满足其生活给水系统用水要求，但在夜间或用水低峰时，市政管网的水压、水量均可满足其用水要求，则该建筑生活给水系统设置下列哪项设施既较为节能又能满足其用水要求？( )",[81,83,85,87],{"key":20,"text":82,"correct":26},"高位调节水箱",{"key":24,"text":84,"correct":22},"变频加压供水设备",{"key":28,"text":86,"correct":22},"低位调节水箱+变频加压供水设备",{"key":31,"text":88,"correct":22},"低位调节水箱+增压泵+高位调节水箱",{"id":90,"libraryId":5,"type":15,"typeLabel":16,"stem":91,"options":92,"answer":24,"analysis":33},878991,"下列关于建筑生活排水处理及其设施的叙述中，哪项正确？( )",[93,95,97,99],{"key":20,"text":94,"correct":22},"住宅厨房含油污水应经过除油处理后方允许排入室外污水管道",{"key":24,"text":96,"correct":26},"温度高于40℃的污水应降温处理",{"key":28,"text":98,"correct":22},"粪便污水应经化粪池处理后方可排入市政污水管道",{"key":31,"text":100,"correct":22},"双格化粪池第一格的容量宜占总容量的60%",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":24,"analysis":33},878992,"下列有关集中热水供应系统加热设备的叙述中，哪项不正确？( )",[105,107,109,111],{"key":20,"text":106,"correct":22},"导流型容积式水加热器罐体容积的利用率高于容积式水加热器",{"key":24,"text":108,"correct":26},"医院集中热水供应系统宜采用供水可靠性较高的导流型容积式水加热器",{"key":28,"text":110,"correct":22},"半容积式水加热器有灵敏、可靠的温控装置时，可不考虑贮热容积",{"key":31,"text":112,"correct":22},"快速式水加热器在被加热水压力不稳定时，出水温度波动大",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":115,"answer":20,"analysis":33},878993,[116,117,118,119],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":20,"analysis":33},878994,"某卫生间采用外径De=32mm的塑料管暗敷在结构楼板和找平层内，经卡套式连接配件向各用水器具供水，地面有管道走向标识。以上给水管道布置的说明中有几处错误？( )",[124,126,128,130],{"key":20,"text":125,"correct":26},"3处",{"key":24,"text":127,"correct":22},"2处",{"key":28,"text":129,"correct":22},"1处",{"key":31,"text":131,"correct":22},"无错",{"id":133,"libraryId":5,"type":15,"typeLabel":16,"stem":134,"options":135,"answer":31,"analysis":33},878995,"关于建筑生活排水立管内的流动规律，以下哪项描述正确？( )",[136,138,140,142],{"key":20,"text":137,"correct":22},"由于排水设计流量的影响，立管内水流状态从附壁流、水膜流和水塞流变化",{"key":24,"text":139,"correct":22},"立管瞬时大流量排水时底部可能出现负压抽吸，导致底层卫生器具存水弯水封被破坏",{"key":28,"text":141,"correct":22},"随着排水量增大，当立管内充满度超过1\u002F3后最终会形成稳定的水塞流",{"key":31,"text":143,"correct":26},"在进行生活排水管道水力计算时，光壁排水立管设计流量所对应的流动状态不是水塞流",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":20,"analysis":33},878996,"以下有关雨水溢流设施的设置要求中，何项是正确的？( )",[148,150,152,154],{"key":20,"text":149,"correct":26},"建筑采用压力流雨水排水系统时，应设置屋面雨水溢流设施",{"key":24,"text":151,"correct":22},"重要公共建筑压力流雨水排水系统与溢流设施的排水量之和不应小于10年重现期的雨水量",{"key":28,"text":153,"correct":22},"建筑采用重力流雨水排水系统且各汇水面积内设有两根或两根以上排水立管时，可不设雨水溢流设施",{"key":31,"text":155,"correct":22},"建筑采用重力流雨水排水系统各汇水面积内仅有一根排水立管时，应设雨水溢流设施，其排水量等同于雨水立管的设计流量",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":31,"analysis":33},878997,"下列哪项因素是规范不推荐高层建筑给水立管采用塑料管的主要原因？( )",[160,162,164,166],{"key":20,"text":161,"correct":22},"塑料给水管的承压较低",{"key":24,"text":163,"correct":22},"塑料给水管易燃",{"key":28,"text":165,"correct":22},"塑料给水管容易老化",{"key":31,"text":167,"correct":26},"塑料给水管容易断裂漏水",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":24,"analysis":33},878998,"某办公建筑的生活给水系统采用市政管网的水压直接供水，其生活给水管的设计流量与下列哪项因素无关？( )",[172,174,176,178],{"key":20,"text":173,"correct":22},"设计使用人数",{"key":24,"text":175,"correct":26},"市政管网供水压力",{"key":28,"text":177,"correct":22},"卫生器具给水当量",{"key":31,"text":179,"correct":22},"卫生器具额定流量",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":24,"analysis":33},878999,"以下有关确定通气管管径的叙述中，哪项正确？( )",[184,186,188,190],{"key":20,"text":185,"correct":22},"排水管管径为DN100，其专用通气立管的最小管径为DN75",{"key":24,"text":187,"correct":26},"9根DN100通气立管的汇合通气总管管径为DN200",{"key":28,"text":189,"correct":22},"与排水立管管径为DN100连接的自循环通气立管的最小管径为DN75",{"key":31,"text":191,"correct":22},"通气立管管径为DN75，其与排水立管相连的结合通气管管径为DN50",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":20,"analysis":33},879000,"以下有关水处理工艺及其处理效果的叙述，哪一项是不正确的？( )",[196,198,200,202],{"key":20,"text":197,"correct":26},"中水处理的主处理工艺包括：混凝、沉淀、过滤、消毒和活性污泥曝气等",{"key":24,"text":199,"correct":22},"毛管渗透系统在去除生物需氧量的同时，还能去除氮磷",{"key":28,"text":201,"correct":22},"在处理水质变化较大的原水时，宜采用较长的工艺流程，以提高处理设施的缓冲能力",{"key":31,"text":203,"correct":22},"消毒处理过程中，消毒剂的化学氧化作用对去除水中耗氧物质有一定的作用",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":24,"analysis":33},879001,"下列关于建筑小区生活排水管道及其检查井的叙述中，哪项不正确？( )",[208,210,212,214],{"key":20,"text":209,"correct":22},"排水管道在管径改变处设检查井",{"key":24,"text":211,"correct":26},"排出管的管顶标高不得高于室外接户管的管顶标高",{"key":28,"text":213,"correct":22},"检查井应优先选用塑料排水检查井",{"key":31,"text":215,"correct":22},"检查井内应做导流槽",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":31,"analysis":33},879002,"以下有关排水系统专用通气管作用的叙述中，哪一项是错误的？( )",[220,222,224,226],{"key":20,"text":221,"correct":22},"污水管道中的有害气体可以通过通气管排至屋顶释放",{"key":24,"text":223,"correct":22},"可提高排水立管的排水能力",{"key":28,"text":225,"correct":22},"可平衡室内排水管道中的压力波动，防止水封破坏",{"key":31,"text":227,"correct":26},"可替代排水系统中的伸顶通气管",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":31,"analysis":33},879003,"下列关于重力流及满管压力流屋面雨水排水系统设计的说法中，哪项正确？( )",[232,234,236,238],{"key":20,"text":233,"correct":22},"重力流屋面雨水排水系统的悬吊管内设计流速不宜小于0.6m\u002Fs",{"key":24,"text":235,"correct":22},"满管压力流屋面雨水排水系统的悬吊管内设计流速不宜小于0.75m\u002Fs",{"key":28,"text":237,"correct":22},"重力流屋面雨水排水系统，其下游排水管管径可小于上游排水管管径",{"key":31,"text":239,"correct":26},"满管压力流屋面雨水排水系统，其下游排水管管径可小于上游排水管管径",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":20,"analysis":33},879004,"以下居住小区的给水系统的水量要求和建筑给水方式的叙述中，哪项是错误的？( )",[244,246,248,250],{"key":20,"text":245,"correct":26},"居住小区的室外给水系统，其水量只需满足居住小区内全部生活用水的要求",{"key":24,"text":247,"correct":22},"居住小区的室外给水系统，其水量应满足居住小区内全部用水的要求",{"key":28,"text":249,"correct":22},"当市政给水管网的水压力不足，但水量满足要求时，可采用设置吸水井和加压设备的给水方式",{"key":31,"text":251,"correct":22},"室外给水管网压力周期性变化，高时满足要求，低时不能满足要求时，其室内给水可采用单设高位水箱的给水方式",{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":28,"analysis":33},879005,"下列根据不同用途选择的雨水处理工艺流程中，不合理的是哪项？( )",[256,258,260,262],{"key":20,"text":257,"correct":22},"屋面雨水→初期径流弃流→排放景观水体",{"key":24,"text":259,"correct":22},"屋面雨水→初期径流弃流→雨水蓄水池沉淀→消毒→雨水清水池→冲洗地面",{"key":28,"text":261,"correct":26},"屋面雨水→初期径流弃流→雨水蓄水池沉淀→过滤→消毒→雨水清水池→补充空调循环冷却水",{"key":31,"text":263,"correct":22},"屋面雨水→初期径流弃流→雨水蓄水池沉淀→处理设备→中水清水池补水",{"id":265,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":266,"answer":28,"analysis":33},879006,[267,269,271,273],{"key":20,"text":268,"correct":22},"排气阀",{"key":24,"text":270,"correct":22},"调速泵",{"key":28,"text":272,"correct":26},"消毒器",{"key":31,"text":274,"correct":22},"循环回水流量控制阀",{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":31,"analysis":33},879007,"下列有关建筑生活给水系统供水方式的说法中，哪项最准确？( )",[279,281,283,285],{"key":20,"text":280,"correct":22},"多层建筑没必要采用分区供水方式",{"key":24,"text":282,"correct":22},"多层建筑没必要采用加压供水方式",{"key":28,"text":284,"correct":22},"高层建筑可不采用分区供水方式",{"key":31,"text":286,"correct":26},"超高层建筑可采用串联供水方式",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":28,"analysis":33},879008,"下列关于建筑排水管道设计，哪项正确？( )",[291,293,295,297],{"key":20,"text":292,"correct":22},"排水立管的排出管径应放大一号",{"key":24,"text":294,"correct":22},"蒸发式冷却器的排水管与污、废水管道系统直接连接",{"key":28,"text":296,"correct":26},"塑料排水管连接采用橡胶密封配件时可不设伸缩节",{"key":31,"text":298,"correct":22},"直径大于50mm的排水管，其间接排水口最小空气间隙应不小于100mm",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":28,"analysis":33},879009,"某建筑内二根长50m，直径分别为DN100mm、DN75mm的排水立管共用一根通气立管，则该通气立管的管径应为下列哪一项？( )",[303,305,307,309],{"key":20,"text":304,"correct":22},"50mm",{"key":24,"text":306,"correct":22},"75mm",{"key":28,"text":308,"correct":26},"100mm",{"key":31,"text":310,"correct":22},"125mm",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":28,"analysis":33},879010,"下列有关结合通气管的连接与替代的叙述中，哪一项是不正确的？( )",[315,317,319,321],{"key":20,"text":316,"correct":22},"用结合通气管连接排水立管和专用通气立管",{"key":24,"text":318,"correct":22},"用结合通气管连接排水立管和主通气立管",{"key":28,"text":320,"correct":26},"用结合通气管连接排水立管和副通气立管",{"key":31,"text":322,"correct":22},"用H管替代结合通气管",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":28,"analysis":33},879011,"某建筑集中热水供应系统，其循环水泵采用温度控制自动运行方式，该循环水泵按配水管网5℃温降散热量设计，在管网实际运行中，下述哪项说法是错误的？( )",[327,329,331,333],{"key":20,"text":328,"correct":22},"管内水温越高，管道散热量相对变大",{"key":24,"text":330,"correct":22},"管内流量越大，供配水管道温降越小",{"key":28,"text":332,"correct":26},"供配水管网的温降基本不受用水量变化的影响",{"key":31,"text":334,"correct":22},"管道保温层厚度越大，管道散热量相对变小",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":28,"analysis":33},879012,"多层住宅室内消火栓系统干式消防竖管的最小管径应为以下哪一项？( )",[339,341,343,345],{"key":20,"text":340,"correct":22},"DN100",{"key":24,"text":342,"correct":22},"DN80",{"key":28,"text":344,"correct":26},"DN65",{"key":31,"text":346,"correct":22},"DN50",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":349,"answer":31,"analysis":33},879013,[350,351,352,353],{"key":20,"text":129,"correct":22},{"key":24,"text":127,"correct":22},{"key":28,"text":125,"correct":22},{"key":31,"text":354,"correct":26},"4处",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":28,"analysis":33},879014,"下列关于建筑给水管材设计选型及管道布置、敷设的叙述中，哪项错误？( )",[359,361,363,365],{"key":20,"text":360,"correct":22},"管材、管件的公称压力应不小于其管道系统的工作压力",{"key":24,"text":362,"correct":22},"需进入维修的管井，其维修通道净宽不宜小于0.6m",{"key":28,"text":364,"correct":26},"卫生器具与冷、热水管连接时，其冷水连接管可设在热水连接管的左侧",{"key":31,"text":366,"correct":22},"高层建筑给水立管不宜采用塑料给水管",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":28,"analysis":33},879015,"下述关于建筑供水系统的供水用途中，哪项是不正确的？( )",[371,373,375,377],{"key":20,"text":372,"correct":22},"生活饮用水系统供烹饪、洗涤、冲厕和沐浴用水",{"key":24,"text":374,"correct":22},"管道直饮水系统供人们直接饮用和烹饪用水",{"key":28,"text":376,"correct":26},"生活给水系统供人们饮用、清洗地面和经营性商业用水",{"key":31,"text":378,"correct":22},"杂用水系统供人们冲洗便器和灌溉花草",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":20,"analysis":33},879016,"下面有关热水供应系统供水方式的叙述哪一项是不正确的？( )",[383,385,387,389],{"key":20,"text":384,"correct":26},"全天循环方式是指热水管网系统保持热水循环，打开各配水龙头随时都能提供符合设计水温要求的热水",{"key":24,"text":386,"correct":22},"开式热水供应方式一般在管网顶部设有高位冷水箱和膨胀管或高位开式加热水箱",{"key":28,"text":388,"correct":22},"闭式热水供应方式的水质不易受到外界污染，但供水水压稳定性和安全可靠性较差",{"key":31,"text":390,"correct":22},"无循环供水方式可用于坡度较小、使用要求不高的定时热水供应系统",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":28,"analysis":33},879017,"高层民用建筑按规范要求设有室内消火栓系统和自动喷水灭火系统，以下设计技术条件中，哪一项是错误的？( )",[395,397,399,401],{"key":20,"text":396,"correct":22},"室内消火栓系统和自动喷水灭火系统可合用高位消防水箱",{"key":24,"text":398,"correct":22},"室内消火栓系统和自动喷水灭火系统可合用消防给水泵",{"key":28,"text":400,"correct":26},"室内消火栓系统和自动喷水灭火系统可合用水泵接合器",{"key":31,"text":402,"correct":22},"室内消火栓系统和自动喷水灭火系统可合用增压设施的气压罐",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":405,"answer":20,"analysis":33},879018,[406,407,408,409],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":412,"answer":28,"analysis":33},879019,[413,415,417,419],{"key":20,"text":414,"correct":22},"3.2L\u002Fs",{"key":24,"text":416,"correct":22},"4.0L\u002F8",{"key":28,"text":418,"correct":26},"4.4L\u002Fs",{"key":31,"text":420,"correct":22},"5.5L\u002Fs",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":20,"analysis":33},879020,"住宅集中热水供应系统配水点的最低水温应为下列哪项？( )",[425,427,429,431],{"key":20,"text":426,"correct":26},"45℃",{"key":24,"text":428,"correct":22},"50℃",{"key":28,"text":430,"correct":22},"55℃",{"key":31,"text":432,"correct":22},"60℃",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":31,"analysis":33},879021,"某住宅建筑供水系统贮水罐的容积以居民的平均日用水量定额计算，应采用下列哪种方法确定定额？( )",[437,439,441,443],{"key":20,"text":438,"correct":22},"规范中日用水定额的下限值",{"key":24,"text":440,"correct":22},"规范中日用水定额除以时变化系数",{"key":28,"text":442,"correct":22},"规范中日用水定额的上、下限中值",{"key":31,"text":444,"correct":26},"规范中日用水定额除以日变化系数",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":31,"analysis":33},879022,"下列有关建筑生活给水系统设计的说法中，哪项正确？( )",[449,451,453,455],{"key":20,"text":450,"correct":22},"当生活给水系统采用分区供水时，每区应分别设置增压供水设备",{"key":24,"text":452,"correct":22},"当利用市政管网水压直接供水时，生活给水系统不必采用分区供水",{"key":28,"text":454,"correct":22},"当生活给水系统采用增压供水时，应设置低位调节构筑物如水箱(池)",{"key":31,"text":456,"correct":26},"当生活给水系统要求水压稳定时，应设置高位调节构筑物如水箱(池)",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":31,"analysis":33},879023,"关于建筑生活排水系统组成，下列哪项正确？( )",[461,463,465,467],{"key":20,"text":462,"correct":22},"高层建筑生活排水系统均应设排水管、通气管、清通设备和污废水提升设施",{"key":24,"text":464,"correct":22},"与生活排水管道相连的卫生器具排水支管上均应设置存水弯",{"key":28,"text":466,"correct":22},"承接公共卫生间的污水立管不允许接地漏排水",{"key":31,"text":468,"correct":26},"各类卫生器具属于建筑生活排水系统的组成部分",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":471,"answer":28,"analysis":33},879024,[472,474,476,478],{"key":20,"text":473,"correct":22},"15L\u002Fs",{"key":24,"text":475,"correct":22},"21L\u002Fs",{"key":28,"text":477,"correct":26},"30L\u002Fs",{"key":31,"text":479,"correct":22},"33L\u002Fs",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":28,"analysis":33},879025,"下列关于建筑叠压供水系统的说法中，哪项不正确？( )",[484,486,488,490],{"key":20,"text":485,"correct":22},"叠压供水工程不会产生二次污染",{"key":24,"text":487,"correct":22},"水压波动过大的给水管网，不得采用叠压供水方式",{"key":28,"text":489,"correct":26},"由叠压供水设备直接给水管网供水时，应按给水设计秒流量选泵",{"key":31,"text":491,"correct":22},"当叠压供水配置气压给水设备时，应符合气压给水设备的设计要求",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":24,"analysis":33},879026,"某建筑物一层为营业餐厅及厨房，二至三层为大型公共浴室，四至十层为宾馆客房，则该建筑排水应至少分几种水质分类推出？( )",[496,498,500,502],{"key":20,"text":497,"correct":22},"1种",{"key":24,"text":499,"correct":26},"2种",{"key":28,"text":501,"correct":22},"3种",{"key":31,"text":503,"correct":22},"4种",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":31,"analysis":33},879027,"以下热水及直饮水供应系统管材选用的叙述中，哪一项是错误的？( )",[508,510,512,514],{"key":20,"text":509,"correct":22},"开水管道应选用许用工作温度大于100℃的金属管材",{"key":24,"text":511,"correct":22},"热水供应设备机房内的管道不应采用塑料热水管",{"key":28,"text":513,"correct":22},"管道直饮水系统当选用铜管时，应限制管内流速在允许范围内",{"key":31,"text":515,"correct":26},"管道直饮水系统应优先选用优质给水塑料管",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":20,"analysis":33},879028,"下列关于建筑生活给水系统配水管网水力计算的说法中，哪项正确？( )",[520,522,524,526],{"key":20,"text":521,"correct":26},"采用分水器配水时，局部水头损失最小",{"key":24,"text":523,"correct":22},"室内配水管道的局部水头损失小于其沿程水头损失",{"key":28,"text":525,"correct":22},"沿程水头损失与管材有关，局部水头损失与管(配)件形式无关",{"key":31,"text":527,"correct":22},"管件内径大于管道内径的局部水头损失小于管件为凹口螺纹的局部水头损失",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":530,"options":531,"answer":28,"analysis":33},879029,"以下有关建筑给水系统分类的叙述中，哪一项是正确的？( )",[532,534,536,538],{"key":20,"text":533,"correct":22},"基本系统为：生活给水系统、生产给水系统、消火栓给水系统",{"key":24,"text":535,"correct":22},"基本系统为：生活给水系统、杂用水给水系统、消防给水系统",{"key":28,"text":537,"correct":26},"基本系统为：生活给水系统、生产给水系统、消防给水系统",{"key":31,"text":539,"correct":22},"基本系统为：生活给水系统、杂用水给水系统、生产给水系统、消防给水系统",{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":24,"analysis":33},879030,"为保证管道直饮水用户端水质，下列哪项措施正确？( )",[544,546,548,550],{"key":20,"text":545,"correct":22},"直饮水配水管宜布置为环状",{"key":24,"text":547,"correct":26},"设循环管道，供、回水管道采用同程布置",{"key":28,"text":549,"correct":22},"循环支管的长度不宜大于3m",{"key":31,"text":551,"correct":22},"直饮水配水立管上装设限流阀",{"id":553,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":554,"answer":20,"analysis":33},879031,[555,556,557,558],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":28,"analysis":33},879032,"下列建筑屋面雨水管道的设计流态中，哪一项是不正确的？( )",[563,565,567,569],{"key":20,"text":564,"correct":22},"檐沟外排水宣按重力流设计",{"key":24,"text":566,"correct":22},"高层建筑屋面雨水排水宜按压力流设计",{"key":28,"text":568,"correct":26},"长天沟外排水宜按压力流设计",{"key":31,"text":570,"correct":22},"大型屋面雨水排水宜按压力流设计",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":24,"analysis":33},879033,"某小区从市政给水管道引入2根给水管，在引入管上加设倒流防止器，并在小区形成室外给水环管，以下哪些做法是正确的？①从小区室外给水环管上接出DN100给水管，设置阀门和倒流防止器后供水至小区低区集中水加热器；②从小区室外给水环管上接出室外消火栓的管道上不设置倒流防止器；③从小区室外给水管网上接出绿化用自动升降式绿地喷灌系统给水管上不设置防倒流污染装置；④从小区室外给水环管接至地下消防水池补水管，其进水口最低点高于溢流边缘的空气间隙为200mm。( )",[575,577,579,581],{"key":20,"text":576,"correct":22},"①③",{"key":24,"text":578,"correct":26},"②④",{"key":28,"text":580,"correct":22},"①④",{"key":31,"text":582,"correct":22},"②③",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":24,"analysis":33},879035,"某建筑生活给水系统采用加压供水方式，下列关于其加压水泵设计扬程计算的说法中，哪项错误？( )",[587,589,591,593],{"key":20,"text":588,"correct":22},"加压水泵扬程与其生活给水系统的设计流量有关",{"key":24,"text":590,"correct":26},"加压水泵扬程与其卫生器具给水配件的配置无关",{"key":28,"text":592,"correct":22},"加压水泵扬程与其生活给水系统采用的管材有关",{"key":31,"text":594,"correct":22},"加压水泵扬程与设计选用的水泵品牌无关",[596,599,602,605,608,611],{"id":15,"name":597,"category":7,"favorite":598},"领导干部任职前廉政法规知识测试题",92,{"id":600,"name":601,"category":7,"favorite":15},595,"建筑结构与设备",{"id":603,"name":604,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":606,"name":607,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":609,"name":610,"category":7,"favorite":8},534,"BIM工程师",{"id":612,"name":610,"category":7,"favorite":8},535]