[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-568-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":604},{"id":5,"name":6,"category":7,"favorite":8},568,"专业知识（给排水）","建筑工程",0,7,50,1213,[13,34,46,58,70,82,94,105,117,129,140,152,164,176,188,200,207,219,231,243,255,267,279,290,302,314,326,338,350,362,374,385,397,409,421,433,444,456,468,480,492,504,516,528,540,552,560,572,580,592],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},878935,1,"单选题","下列关于建筑室内消火栓给水系统设计的叙述中，哪项错误？( )",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","高层建筑的室内消火栓给水管道应布置成环状",false,{"key":24,"text":25,"correct":22},"B","单层、多层建筑的室内消火栓给水管道不一定要布置成环状",{"key":27,"text":28,"correct":29},"C","建筑高度≤100m的高层建筑的室内消火栓水枪的充实水柱不应小于10m",true,{"key":31,"text":32,"correct":22},"D","建筑高度为23.80m的7层办公楼的室内消火栓水枪的充实水柱不应小于10m","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},878936,"下列哪项建筑物的室内消防给水系统可不设置消防水泵接合器？( )",[38,40,42,44],{"key":20,"text":39,"correct":22},"只有一条市政进水管的高层住宅室内消火栓给水系统",{"key":24,"text":41,"correct":22},"多层办公楼的自动喷水灭火系统(轻危险级)",{"key":27,"text":43,"correct":22},"高层仓库的室内消火栓给水系统",{"key":31,"text":45,"correct":29},"5层旅馆的室内消火栓给水系统",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},878937,"某建筑物室(建筑高度小于24m)外消防用水量大于15L\u002Fs，当其室内设置消火栓数量不超过下列何值时，其室内消火栓管网可采用枝状管网的布置形式？( )",[50,52,54,56],{"key":20,"text":51,"correct":22},"5个",{"key":24,"text":53,"correct":22},"8个",{"key":27,"text":55,"correct":29},"10个",{"key":31,"text":57,"correct":22},"12个",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},878938,"某电缆隧道设有水喷雾灭火系统，其水雾喷头的工作压力不应小于下列哪项？( )",[62,64,66,68],{"key":20,"text":63,"correct":22},"0.20MPa",{"key":24,"text":65,"correct":29},"0.35MPa",{"key":27,"text":67,"correct":22},"0.60MPa",{"key":31,"text":69,"correct":22},"0.90MPa",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},878939,"下列有关热水供应系统设计参数的叙述中，哪项不正确？( )",[74,76,78,80],{"key":20,"text":75,"correct":22},"设计小时耗热量是使用热水的用水设备、器具用水量最大时段内小时耗热量",{"key":24,"text":77,"correct":29},"同一建筑不论采用全日或定时热水供应系统，其设计小时耗热量是相同的",{"key":27,"text":79,"correct":22},"设计小时供热量是加热设备供水最大时段内的小时产热量",{"key":31,"text":81,"correct":22},"同一建筑的集中热水供应系统选用不同加热设备时，其设计小时供热量是不同的",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},878940,"以下有关建筑排水系统组成的要求中，哪项是不合理的？( )",[86,88,90,92],{"key":20,"text":87,"correct":22},"系统中均应设置清通设备",{"key":24,"text":89,"correct":29},"与生活污水管井相连的各类卫生器具的排水口下均须设置存水弯",{"key":27,"text":91,"correct":22},"建筑标准要求高的高层建筑的生活污水立管宜设置专用通气立管",{"key":31,"text":93,"correct":22},"生活污水不符合直接排入市政管网的要求时，系统中应设局部处理构筑物",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},878941,"下列哪项建筑物不必设置室内消火栓给水系统？( )",[98,100,101,103],{"key":20,"text":99,"correct":22},"建筑面积500㎡的戊类厂房",{"key":24,"text":33,"correct":29},{"key":27,"text":102,"correct":22},"建筑面积360㎡的油浸变压器室",{"key":31,"text":104,"correct":22},"首层为商业网点的6层普通公寓",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":24,"analysis":33},878942,"某博物馆珍宝库长×宽×高=30m×25m×6m，拟设置七氟丙烷气体灭火系统，下列系统设置中，哪项正确合理？( )",[109,111,113,115],{"key":20,"text":110,"correct":22},"采用管网灭火系统，设一个防护区",{"key":24,"text":112,"correct":29},"采用管网灭火系统，设两个防护区",{"key":27,"text":114,"correct":22},"采用预制灭火系统，设两个防护区，每区设一台预制气体灭火系统装置",{"key":31,"text":116,"correct":22},"采用预制灭火系统，设两个防护区，每区设两台预制气体灭火系统装置",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":31,"analysis":33},878943,"下列关于管道直饮水系统设计流量计算的叙述中，哪项正确？( )",[121,123,125,127],{"key":20,"text":122,"correct":22},"管道直饮水系统的设计秒流量与建筑物性质无关",{"key":24,"text":124,"correct":22},"管道直饮水系统的设计秒流量与饮水定额无关",{"key":27,"text":126,"correct":22},"管道直饮水系统的设计秒流量与饮水人数无关",{"key":31,"text":128,"correct":29},"管道直饮水系统的设计秒流量与饮水系统供水方式无关",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":131,"answer":31,"analysis":33},878944,[132,134,136,138],{"key":20,"text":133,"correct":22},"无错误",{"key":24,"text":135,"correct":22},"1处",{"key":27,"text":137,"correct":22},"2处",{"key":31,"text":139,"correct":29},"3处",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":31,"analysis":33},878945,"下列关于建筑灭火器配置设计的叙述中，哪项不准确？( )",[144,146,148,150],{"key":20,"text":145,"correct":22},"甲、乙类物品生产厂房灭火器应按严重危险配置",{"key":24,"text":147,"correct":22},"同一场所存在两种类型火灾，可配置同一类型通用型灭火器",{"key":27,"text":149,"correct":22},"灭火器箱可悬挂在墙壁或柱子上，但箱顶离地(楼)面的距离不应大于1.5m",{"key":31,"text":151,"correct":29},"对于危险等级相同的同一楼层或防火区分，可将其作为一个计算单元配置灭火器",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":31,"analysis":33},878946,"下列关于建筑中水处理工艺设计的叙述中，哪项错误？( )",[156,158,160,162],{"key":20,"text":157,"correct":22},"当采用生活污水水源时，宜设置二段生物处理",{"key":24,"text":159,"correct":22},"当采用优质杂排水水源时，可采用物化处理工艺",{"key":27,"text":161,"correct":22},"当中水处理规模很小时，其产生的污泥可排入化粪池处理",{"key":31,"text":163,"correct":29},"当中水仅用于景观用水和浇洒道路时，其消毒工艺可只设置紫外线消毒",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":31,"analysis":33},878947,"下述水喷雾灭火系统的组件和控制方式中，哪项是错误的？( )",[168,170,172,174],{"key":20,"text":169,"correct":22},"水喷雾灭火系统应设有自动控制、手动控制和应急操作三种控制方式",{"key":24,"text":171,"correct":22},"水喷雾灭火系统的雨淋阀可由电控信号、传动管液动信号或传动管气动信号进行开启",{"key":27,"text":173,"correct":22},"水喷雾灭火系统的火灾探测器可采用缆式线型定温型、空气管式感温形或闭式喷头",{"key":31,"text":175,"correct":29},"水喷雾灭火系统由水源、供水泵、管道、过滤器、水雾喷头组成",{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":24,"analysis":33},878948,"对于采用蒸汽直接通入水中的加热方式，为防止加热水箱内的水倒流至蒸汽管，拟采取下列措施：①设置限流阀；②设置止回装置；③设置温控阀；④设置消声器；⑤抬高热水管标高；⑥抬高蒸汽管标高；⑦抬高冷水箱标高。上述措施中有几项正确？( )",[180,182,184,186],{"key":20,"text":181,"correct":22},"1项正确，正确项为②",{"key":24,"text":183,"correct":29},"2项正确，正确项为②、⑥",{"key":27,"text":185,"correct":22},"3项正确，正确项为②、⑤、⑥",{"key":31,"text":187,"correct":22},"4项正确，正确项为②、⑤、⑥、⑦",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":31,"analysis":33},878949,"湿式自动喷水灭火系统由下列哪种方式自动启动？( )",[192,194,196,198],{"key":20,"text":193,"correct":22},"由温感探测器动作自动启动",{"key":24,"text":195,"correct":22},"由烟感探测器动作自动启动",{"key":27,"text":197,"correct":22},"由温感和烟感两路探测器同时动作自动启动",{"key":31,"text":199,"correct":29},"由闭式喷头动作自动启动",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":202,"answer":31,"analysis":33},878950,[203,204,205,206],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":31,"text":33,"correct":29},{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":24,"analysis":33},878951,"根据各类建筑排水(作为中水原水)水质，下列其中水处理难度、费用排序中(处理难度由难至易，费用由高至低)，哪项正确？( )",[211,213,215,217],{"key":20,"text":212,"correct":22},"宾馆＞营业餐厅＞住宅＞办公楼",{"key":24,"text":214,"correct":29},"营业餐厅＞住宅＞办公楼＞宾馆",{"key":27,"text":216,"correct":22},"住宅＞宾馆＞办公楼＞营业餐厅",{"key":31,"text":218,"correct":22},"办公楼＞营业餐厅＞宾馆＞住宅",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":31,"analysis":33},878952,"下列关于建筑灭火器选型设计的说明，哪项错误？( )",[223,225,227,229],{"key":20,"text":224,"correct":22},"汽油库可选择碳酸氢钠干粉灭火器",{"key":24,"text":226,"correct":22},"液化石油气储库可选择磷酸铵盐干粉灭火器",{"key":27,"text":228,"correct":22},"铝粉生产车间应配置专用灭火器",{"key":31,"text":230,"correct":29},"变配电房配置泡沫灭火器",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":24,"analysis":33},878953,"下列关于建筑热水供应系统和方式的选择，哪项正确？( )",[235,237,239,241],{"key":20,"text":236,"correct":22},"由区域热水供应的建筑群，应采用局部热水供应系统",{"key":24,"text":238,"correct":29},"设有5个淋浴器的车间公共浴室，应采用集中热水供应系统",{"key":27,"text":240,"correct":22},"对于大型公共建筑，应采用全日制集中热水供应系统",{"key":31,"text":242,"correct":22},"在热水用量小或用水点分散时，宜采用局部热水供应系统",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":27,"analysis":33},878954,"有关热水供应系统和供水方式的选择，下列哪项正确？( )",[247,249,251,253],{"key":20,"text":248,"correct":22},"太阳能加热系统不适宜用于冷、热水压力平衡要求较高的建筑中",{"key":24,"text":250,"correct":22},"蒸汽间接加热方式不适宜用于冷、热水压力平衡要求较高的建筑中",{"key":27,"text":252,"correct":29},"另设热水加压泵的方式不适宜用于冷、热水压力平衡要求较高的建筑中",{"key":31,"text":254,"correct":22},"水源热泵加热系统不适宜适用于冷、热水压力平衡要求较高的建筑中",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":20,"analysis":33},878955,"关于建筑排水设计流量计算，以下哪项正确？( )",[259,261,263,265],{"key":20,"text":260,"correct":29},"用水时段较为集中的建筑物，排水设计秒流量采用同时排水百分数法",{"key":24,"text":262,"correct":22},"公共建筑物内的大便器同时排水百分数，与同时给水百分数相同",{"key":27,"text":264,"correct":22},"公共建筑物生活排水小时变化系数，与生活给水用水小时变化系数不相同",{"key":31,"text":266,"correct":22},"住宅的生活排水设计秒流量，直接与当地气候条件和生活习惯有关",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":24,"analysis":33},878956,"雨水供水系统的补水流量应以下列哪项为依据进行计算？( )",[271,273,275,277],{"key":20,"text":272,"correct":22},"不大于管网系统最大时用水量",{"key":24,"text":274,"correct":29},"不小于管网系统最大时用水量",{"key":27,"text":276,"correct":22},"管网系统最高日用水量",{"key":31,"text":278,"correct":22},"管网系统平均时用水量",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":281,"answer":27,"analysis":33},878957,[282,284,286,288],{"key":20,"text":283,"correct":22},"20L\u002Fs",{"key":24,"text":285,"correct":22},"35L\u002Fs",{"key":27,"text":287,"correct":29},"45L\u002Fs",{"key":31,"text":289,"correct":22},"50L\u002Fs",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":31,"analysis":33},878958,"对于游泳池的净化处理工艺，下列哪种说法不正确？( )",[294,296,298,300],{"key":20,"text":295,"correct":22},"硅藻土过滤器的过滤精度优于石英砂过滤",{"key":24,"text":297,"correct":22},"游泳池可利用市政自来水进行反冲洗",{"key":27,"text":299,"correct":22},"利用游泳池水进行反冲洗有利于改善游泳池水质",{"key":31,"text":301,"correct":29},"过滤器反冲洗水泵应设置备用泵",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":31,"analysis":33},878959,"以下关于室内消火栓用水量设计的叙述中，哪一项是错误的？( )",[306,308,310,312],{"key":20,"text":307,"correct":22},"住宅中设置干式消防竖管的DN65消火栓的用水量，不计入室内消防用水量",{"key":24,"text":309,"correct":22},"消防软管卷盘的用水量，设计时不计入室内消防用水量",{"key":27,"text":311,"correct":22},"平屋顶上设置的试验和检查用消火栓用水量，设计时不计入室内消防用水量",{"key":31,"text":313,"correct":29},"冷库内设置在常温穿堂的消火栓用水量，设计时不计入室内消防用水量",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":31,"analysis":33},878960,"露天游泳池一般适合采用下列哪种消毒剂？( )",[318,320,322,324],{"key":20,"text":319,"correct":22},"液氯",{"key":24,"text":321,"correct":22},"次氯酸钠",{"key":27,"text":323,"correct":22},"臭氧",{"key":31,"text":325,"correct":29},"二氯尿氰酸钠",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":24,"analysis":33},878961,"下列关于游泳池过滤器的设计要求中，何项是错误的？( )",[330,332,334,336],{"key":20,"text":331,"correct":22},"竞赛池、训练池、公共池的过滤器应分开设置，不能共用",{"key":24,"text":333,"correct":29},"过滤器的数量不宜少于2台，且应考虑备用",{"key":27,"text":335,"correct":22},"压力过滤器应设置布水、集水均匀的布、集水装置",{"key":31,"text":337,"correct":22},"为提高压力过滤器的反洗效果，节省反洗水量，可设气、水组合反冲洗装置",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":27,"analysis":33},878962,"下列有关水喷雾灭火系统水雾喷头布置要求的叙述中，哪项错误？( )",[342,344,346,348],{"key":20,"text":343,"correct":22},"当水喷雾保护输送机皮带时，喷头喷雾应完全包围输送机的机头、机尾和上、下行皮带",{"key":24,"text":345,"correct":22},"当水喷雾保护电缆时，喷头喷雾应完全包围电缆",{"key":27,"text":347,"correct":29},"当水喷雾保护液体储罐时，水雾喷头与保护液面之间的距离不应大于0.7m",{"key":31,"text":349,"correct":22},"当水喷雾保护油浸电力变压器时，水喷雾布置的垂直和水平间距应满足水雾锥相交的要求",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":24,"analysis":33},878963,"下列关于建筑中水水源选择的叙述中，哪项正确？( )",[354,356,358,360],{"key":20,"text":355,"correct":22},"综合医院污水作为中水水源，经消毒后可用于洗车",{"key":24,"text":357,"correct":29},"以厨房废水作为中水水源时，应经隔油处理后方可进入中水原水系统",{"key":27,"text":359,"correct":22},"比较某校区的教学楼、公共浴室作为中水水源，在平均日排水量相同的情况下，宜优先选择教学楼",{"key":31,"text":361,"correct":22},"传染病医院雨水作为中水水源，经消毒后达成城市绿化水质标准时，可用于绿化浇洒",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":24,"analysis":33},878964,"设计居住小区的生活排水调节池时，其调节池有效容积应按不大于下列哪项计算？( )",[366,368,370,372],{"key":20,"text":367,"correct":22},"其最大时的生活污水量",{"key":24,"text":369,"correct":29},"其平均时6小时的生活污水量",{"key":27,"text":371,"correct":22},"其平均时12小时的生活污水量",{"key":31,"text":373,"correct":22},"其24小时的生活污水量",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":376,"answer":20,"analysis":33},878965,[377,379,381,383],{"key":20,"text":378,"correct":29},"3640；26",{"key":24,"text":380,"correct":22},"9490；26",{"key":27,"text":382,"correct":22},"3640；10",{"key":31,"text":384,"correct":22},"3640；13",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":24,"analysis":33},878966,"以下有关集中热水供应系统热源选择的叙述中哪一项是错误的？( )",[389,391,393,395],{"key":20,"text":390,"correct":22},"采用汽锤用汽设备排出废汽作为热媒加热时，应设除油器除去废汽中的废油",{"key":24,"text":392,"correct":29},"在太阳能资源较丰富的地区，利用太阳能为热源时，不需设辅助加热装置",{"key":27,"text":394,"correct":22},"经技术经济比较，可选择电蓄热设备为集中热水供应系统的热源",{"key":31,"text":396,"correct":22},"采用蒸汽直接通入水箱中加热时，应采取防止热水倒流至蒸汽管道的措施",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":24,"analysis":33},878967,"以下关于居住小区跟公共建筑生活排水定额及小时变化系数的叙述，何项正确？( )",[401,403,405,407],{"key":20,"text":402,"correct":22},"居住小区生活排水定额与其相应的生活给水系统用水定额不同，故二者的小时变化系数也不相同",{"key":24,"text":404,"correct":29},"居住小区生活排水定额小于其相应的生活给水系统用水定额，故二者的小时变化系数相同",{"key":27,"text":406,"correct":22},"公共建筑生活排水定额等于其相应的生活给水系统用水定额，故二者的小时变化系数不相同",{"key":31,"text":408,"correct":22},"公共建筑生活排水定额小于其相应的生活给水系统用水定额，故二者的小时变化系数也不相同",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":27,"analysis":33},878968,"下列关于工业区的消防灭火系统设计的叙述中，哪项错误？( )",[413,415,417,419],{"key":20,"text":414,"correct":22},"工厂、仓库的室外消防用水量应按同一时间内的火灾起数和一起火灾灭火所需室外消防用水量确定",{"key":24,"text":416,"correct":22},"丙类可燃液体储罐区的室外消防用水量应为灭火用水量和冷却用水量之和",{"key":27,"text":418,"correct":29},"厂房、仓库设有自动喷水灭火系统时，可不再另外设置灭火器",{"key":31,"text":420,"correct":22},"埋地的液化石油气储罐可不设置固定喷水冷却装置",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":20,"analysis":33},878969,"某全日制循环的管道直饮水系统，拟将变频调速供水泵兼做循环泵，则水泵设计流量应根据下列哪项流量确定？( )",[425,427,429,431],{"key":20,"text":426,"correct":29},"瞬时高峰流量(或设计秒流量)",{"key":24,"text":428,"correct":22},"最大小时流量",{"key":27,"text":430,"correct":22},"瞬时高峰流量+循环流量",{"key":31,"text":432,"correct":22},"最大小时流量+循环流量",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":435,"answer":24,"analysis":33},878970,[436,438,440,442],{"key":20,"text":437,"correct":22},"2860kW",{"key":24,"text":439,"correct":29},"1945kW",{"key":27,"text":441,"correct":22},"1692kW",{"key":31,"text":443,"correct":22},"895kW",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":20,"analysis":33},878971,"某别墅住宅小区共20户(每户4人)，最高日生活用水定额为250L\u002F(人·d)，每户庭院绿化面积30㎡，小车停车位2个(每天一次微水冲洗1辆)，则每户日用水量最多不应大于下列哪项？( )",[448,450,452,454],{"key":20,"text":449,"correct":29},"1000L\u002Fd",{"key":24,"text":451,"correct":22},"1090L\u002Fd",{"key":27,"text":453,"correct":22},"1105L\u002Fd",{"key":31,"text":455,"correct":22},"1120L\u002Fd",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":27,"analysis":33},878972,"以下有关热水供应系统第二循环管网循环水泵的叙述中，哪项正确？( )",[460,462,464,466],{"key":20,"text":461,"correct":22},"循环水泵的扬程应满足最不利配水点最低工作压力的要求",{"key":24,"text":463,"correct":22},"循环水泵的壳体所承受的工作压力应以水泵的扬程计",{"key":27,"text":465,"correct":29},"全日制或定时热水供应系统中，循环水泵流量的计算方法不同",{"key":31,"text":467,"correct":22},"全日制热水供应系统中，控制循环水泵启闭的为最不利配水点的使用水温",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":27,"analysis":33},878973,"下列关于中水处理和其水质要求的说法中，哪项正确？( )",[472,474,476,478],{"key":20,"text":473,"correct":22},"中水用于景观水体时可不进行消毒以免伤害水中鱼类等生物",{"key":24,"text":475,"correct":22},"当住宅区内的中水用于植物滴灌时，可不做消毒处理",{"key":27,"text":477,"correct":29},"当中水用于冲厕时，其水质应符合有关国家标准的规定",{"key":31,"text":479,"correct":22},"中水用于多种用途时，处理工艺可按用水量最大者的水质要求确定",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":27,"analysis":33},878974,"下列有关建筑生活给水系统组成的说法中，哪项最准确？( )",[484,486,488,490],{"key":20,"text":485,"correct":22},"采用加压供水时，必须设置调节构筑物如水箱(池)",{"key":24,"text":487,"correct":22},"利用市政供水压力直接供水时，没必要设置调节构筑物如水箱(池)",{"key":27,"text":489,"correct":29},"当市政供水量不满足高峰用水量要求时，必须设置调节构筑物如水箱(池)",{"key":31,"text":491,"correct":22},"当市政供水压力在高峰期不满足设计水压要求时，必须设置加压供水设备",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":31,"analysis":33},878975,"卫生器具给水配件承受的最大工作压力(MPa)，为下列哪项？( )",[496,498,500,502],{"key":20,"text":497,"correct":22},"0.35",{"key":24,"text":499,"correct":22},"0.45",{"key":27,"text":501,"correct":22},"0.55",{"key":31,"text":503,"correct":29},"0.60",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":24,"analysis":33},878976,"在多、高层住宅的给水系统中，下列哪项不允许设在户内？( )",[508,510,512,514],{"key":20,"text":509,"correct":22},"住户水表",{"key":24,"text":511,"correct":29},"立管上的阀门",{"key":27,"text":513,"correct":22},"支管上的减压阀",{"key":31,"text":515,"correct":22},"卡压式接头",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":24,"analysis":33},878977,"关于建筑屋面雨水管系设计，以下表述中哪项正确？( )",[520,522,524,526],{"key":20,"text":521,"correct":22},"重力流屋面雨水排水管系的埋地管，按满管压力流设计",{"key":24,"text":523,"correct":29},"降低压力流屋面雨水排水管内流速，会增大管系中的动压",{"key":27,"text":525,"correct":22},"大型厂房屋面雨水排水管系的总水头损失，应按海增-威廉公式计算",{"key":31,"text":527,"correct":22},"压力流屋面雨水悬吊管末端的负压绝对值越大，排水作用压力越小",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":530,"options":531,"answer":27,"analysis":33},878978,"下列关于高层建筑热水供应系统设计的叙述中，哪项错误？( )",[532,534,536,538],{"key":20,"text":533,"correct":22},"热水供应系统分区应与冷水给水系统一致",{"key":24,"text":535,"correct":22},"热水供应系统采用的减压阀，其材质与冷水系统不同",{"key":27,"text":537,"correct":29},"采用减压阀分区的热水供应系统可共用第二循环泵",{"key":31,"text":539,"correct":22},"减压阀分区的热水供应系统不节能",{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":20,"analysis":33},878979,"水喷雾灭火系统广泛用于石油化工、电力、冶金等行业，但不适用于下列哪种？( )",[544,546,548,550],{"key":20,"text":545,"correct":29},"高温密闭空间内的火灾",{"key":24,"text":547,"correct":22},"饮料、酒火灾",{"key":27,"text":549,"correct":22},"高压电极产生的火灾",{"key":31,"text":551,"correct":22},"固体物质火灾",{"id":553,"libraryId":5,"type":15,"typeLabel":16,"stem":554,"options":555,"answer":27,"analysis":33},878980,"某集体宿舍共320人，设有冷热水供应系统，最高日生活用水定额以150L\u002F天·人计，最高日热水定额以70L\u002F天·人计，则该宿舍最高日用水量应为下列何项？( )",[556,557,558,559],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":29},{"key":31,"text":33,"correct":22},{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":24,"analysis":33},878981,"下列哪种灭火系统不能自动启动？( )",[564,566,568,570],{"key":20,"text":565,"correct":22},"水喷雾灭火系统",{"key":24,"text":567,"correct":29},"临时高压消火栓系统",{"key":27,"text":569,"correct":22},"雨淋系统",{"key":31,"text":571,"correct":22},"组合式气体灭火系统",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":574,"answer":31,"analysis":33},878982,[575,576,577,578],{"key":20,"text":135,"correct":22},{"key":24,"text":137,"correct":22},{"key":27,"text":139,"correct":22},{"key":31,"text":579,"correct":29},"≥4处",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":31,"analysis":33},878983,"高层民用建筑消火栓给水系统在运行时的最高压力不应超过下列哪项？( )",[584,586,588,590],{"key":20,"text":585,"correct":22},"1.2MPa",{"key":24,"text":587,"correct":22},"1.6MPa",{"key":27,"text":589,"correct":22},"2.0MPa",{"key":31,"text":591,"correct":29},"2.4MPa",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":27,"analysis":33},878984,"水表一般有以下几种特性流量，某生产车间内的公共浴室用水单独设置水表计算，按给水设计流量选定水表，应以水表的哪种流量判定？( )",[596,598,600,602],{"key":20,"text":597,"correct":22},"分界流量",{"key":24,"text":599,"correct":22},"过载流量",{"key":27,"text":601,"correct":29},"常用流量",{"key":31,"text":603,"correct":22},"始动流量",[605,608,611,614,617,620],{"id":15,"name":606,"category":7,"favorite":607},"领导干部任职前廉政法规知识测试题",92,{"id":609,"name":610,"category":7,"favorite":15},595,"建筑结构与设备",{"id":612,"name":613,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":615,"name":616,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":618,"name":619,"category":7,"favorite":8},534,"BIM工程师",{"id":621,"name":619,"category":7,"favorite":8},535]