[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-568-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":602},{"id":5,"name":6,"category":7,"favorite":8},568,"专业知识（给排水）","建筑工程",0,6,50,1213,[13,34,41,53,65,77,89,101,113,125,137,149,161,173,185,197,209,220,232,242,254,266,278,290,297,304,316,327,339,350,362,374,386,398,410,422,434,446,458,470,482,494,506,518,530,542,554,566,578,590],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},878883,1,"单选题","工程设计需采用局部应用气体灭火系统时，应选择下列哪种系统？( )",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","七氟丙烷灭火系统",false,{"key":24,"text":25,"correct":22},"B","IG541混合气体灭火系统",{"key":27,"text":28,"correct":22},"C","热气溶胶预制灭火系统",{"key":30,"text":31,"correct":32},"D","二氧化碳灭火系统",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":36,"answer":27,"analysis":33},878884,[37,38,39,40],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":32},{"key":30,"text":33,"correct":22},{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":33},878885,"某高层住宅室内消火栓给水系统采用临时高压系统，平时用高位水箱稳压，消防水泵设在地下室。该消火栓给水系统在下列哪项条件下应采用分区供水？( )",[45,47,49,51],{"key":20,"text":46,"correct":32},"高位水箱的内底面与最低处消火栓栓口的高差为100m",{"key":24,"text":48,"correct":22},"高位水箱的最高水位与最低处消火栓栓口的高差为100m",{"key":27,"text":50,"correct":22},"消火栓给水泵的设计扬程为1.0MPa",{"key":30,"text":52,"correct":22},"消火栓给水泵出口的水压为1.0MPa",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":27,"analysis":33},878886,"某建筑设置的七氟丙烷管网灭火系统，其储存容器的增压压力为4.2MPa，下列关于该系统的设计，哪项不正确？( )",[57,59,61,63],{"key":20,"text":58,"correct":22},"储存容器采用焊接容器",{"key":24,"text":60,"correct":22},"该系统的设计喷放时间为8s",{"key":27,"text":62,"correct":32},"该系统共设置8个选择阀防护9个房间",{"key":30,"text":64,"correct":22},"管网计算结果：喷头处的工作压力为0.6MPa(绝对压力)",{"id":66,"libraryId":5,"type":15,"typeLabel":16,"stem":67,"options":68,"answer":24,"analysis":33},878887,"某住宅和宾馆各设有一套连续运行的中水处理设施，其原水为各自的综合排水。两者处理能力、处理工艺及出水水质完全相同。则下列两套设施接触氧化池气水比的叙述中正确的是哪项？( )",[69,71,73,75],{"key":20,"text":70,"correct":22},"两套设施中接触氧化池所要求的气水比相同",{"key":24,"text":72,"correct":32},"设在宾馆的接触氧化池所要求的气水比较小",{"key":27,"text":74,"correct":22},"设在住宅的接触氧化池所要求的气水比较小",{"key":30,"text":76,"correct":22},"气水比应根据接触氧化池所采用的水力停留时间确定",{"id":78,"libraryId":5,"type":15,"typeLabel":16,"stem":79,"options":80,"answer":27,"analysis":33},878888,"下列高层建筑消防系统设置的叙述中，哪项是正确的？( )",[81,83,85,87],{"key":20,"text":82,"correct":22},"高层建筑必须设置室内消火栓给水系统，宜设置室外消火栓给水系统",{"key":24,"text":84,"correct":22},"高层建筑宜设置室内、室外消火栓给水系统",{"key":27,"text":86,"correct":32},"高层建筑必须设置室内、室外消火栓给水系统",{"key":30,"text":88,"correct":22},"高层建筑必须设置室内、室外消火栓给水系统和自动喷水灭火系统",{"id":90,"libraryId":5,"type":15,"typeLabel":16,"stem":91,"options":92,"answer":20,"analysis":33},878889,"下列关于气体灭火系统设计的叙述中，哪项错误？( )",[93,95,97,99],{"key":20,"text":94,"correct":32},"气体灭火系统适用于扑救可燃固体物质的深位火灾",{"key":24,"text":96,"correct":22},"气体灭火系统适用于扑救电气火灾",{"key":27,"text":98,"correct":22},"气体灭火系统适用于扑救液体火灾",{"key":30,"text":100,"correct":22},"防护区的最低环境温度不应低于-10℃",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":30,"analysis":33},878890,"某省级电力调度大楼的通信指挥中心机房宜优先配置下列哪种灭火器？( )",[105,107,109,111],{"key":20,"text":106,"correct":22},"泡沫灭火器",{"key":24,"text":108,"correct":22},"二氧化碳灭火器",{"key":27,"text":110,"correct":22},"水型灭火器",{"key":30,"text":112,"correct":32},"磷酸铵盐干粉灭火器",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":115,"options":116,"answer":24,"analysis":33},878891,"预作用系统准工作状态时，报警阀后配水管道不充水，开启报警阀后使配水管道充水转换为湿式系统。《自动喷水灭火系统设计规范》规定采用的是下列哪一种自动控制方式？( )",[117,119,121,123],{"key":20,"text":118,"correct":22},"气动连锁系统",{"key":24,"text":120,"correct":32},"电气连锁系统",{"key":27,"text":122,"correct":22},"无连锁系统",{"key":30,"text":124,"correct":22},"双连锁系统",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":24,"analysis":33},878892,"某绿化广场下的单层独立地下车库建筑面积为3850㎡，车位110个，设有湿式自动喷水灭火系统。该自动喷水灭火系统中可不设置下列哪项组件？( )",[129,131,133,135],{"key":20,"text":130,"correct":22},"报警阀组",{"key":24,"text":132,"correct":32},"水流指示器",{"key":27,"text":134,"correct":22},"压力开关",{"key":30,"text":136,"correct":22},"末端试水装置",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":27,"analysis":33},878893,"某多层酒店，地下一层为汽车库，该建筑自动喷水灭火系统设计参数按哪种危险等级取值？( )",[141,143,145,147],{"key":20,"text":142,"correct":22},"轻危险级",{"key":24,"text":144,"correct":22},"中危险工级",{"key":27,"text":146,"correct":32},"中危险Ⅱ级",{"key":30,"text":148,"correct":22},"严重危险级",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":27,"analysis":33},878894,"某汽车库拟配置手提式磷酸铵盐干粉灭火器，按灭火器最低配置基准应选用下列哪种型号灭火器(汽车库场所主要存在B类及A类火灾)？( )",[153,155,157,159],{"key":20,"text":154,"correct":22},"MF\u002FABC2",{"key":24,"text":156,"correct":22},"MF\u002FABC3",{"key":27,"text":158,"correct":32},"MF\u002FABC4",{"key":30,"text":160,"correct":22},"以上灭火器型号均不能选用",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":24,"analysis":33},878895,"某数据处理控制中心设有七氟丙烷气体灭火系统，系统启动灭火时，防护区实际使用浓度不应大于下列哪项？( )",[165,167,169,171],{"key":20,"text":166,"correct":22},"灭火设计浓度",{"key":24,"text":168,"correct":32},"有毒性反应浓度",{"key":27,"text":170,"correct":22},"惰化设计浓度",{"key":30,"text":172,"correct":22},"无毒性反应浓度",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":27,"analysis":33},878896,"下列为某医院建筑(建筑高度为30m)的地下室空调机房自动灭火系统设计方案，哪项设计方案最合理？( )",[177,179,181,183],{"key":20,"text":178,"correct":22},"设置气体灭火系统",{"key":24,"text":180,"correct":22},"设置水喷雾灭火系统",{"key":27,"text":182,"correct":32},"设置湿式自动喷水灭火系统",{"key":30,"text":184,"correct":22},"不设自动灭火系统",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":27,"analysis":33},878897,"下列有关建筑消防设计的说法中，哪项错误？( )",[189,191,193,195],{"key":20,"text":190,"correct":22},"专用电子计算机房应按严重危险级配置灭火器",{"key":24,"text":192,"correct":22},"木材加工车间的火灾危险性为丙类",{"key":27,"text":194,"correct":32},"医院氮气储存间的火灾危险性为丁类",{"key":30,"text":196,"correct":22},"大、中型地下停车场应按中危Ⅱ级设计自动喷水灭火系统",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":27,"analysis":33},878900,"下列关于高层建筑消火栓给水系统设计的叙述中，哪项不正确？( )",[201,203,205,207],{"key":20,"text":202,"correct":22},"采用高压消防给水系统时，可不设高位消防水箱",{"key":24,"text":204,"correct":22},"建筑高度超过100m的民用建筑，室内消火栓系统应采用分区供水方式",{"key":27,"text":206,"correct":32},"高层建筑电梯间应设置室内消火栓",{"key":30,"text":208,"correct":22},"高层建筑室内外消火栓栓口处的水压不应小于0.10MPa",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":211,"answer":24,"analysis":33},878901,[212,214,216,218],{"key":20,"text":213,"correct":22},"高区消防泵先启动，低区消防泵联动启动",{"key":24,"text":215,"correct":32},"低区消防泵先启动，高区消防泵联动启动",{"key":27,"text":217,"correct":22},"高、低区消防泵同时启动",{"key":30,"text":219,"correct":22},"无论哪区消防泵先启动，只要高区消防泵能及时启动就可以",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":27,"analysis":33},878902,"下列关于建筑给水系统加压设施设计的说法中，哪项正确？( )",[224,226,228,230],{"key":20,"text":225,"correct":22},"当两台水泵为一用一备时，其出水管上共用止回阀和阀门",{"key":24,"text":227,"correct":22},"当水泵从水箱(池)自灌式直接吸水加压时，其吸水管口未设置喇叭口",{"key":27,"text":229,"correct":32},"当由高位水箱供水且其内底板面高度满足最高层用水要求时，未设增压设施",{"key":30,"text":231,"correct":22},"当高位水箱采用水泵加压补水时，采用直接作用式浮球阀控制水箱水位",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":27,"analysis":33},878903,"下列关于公共建筑用水情况以及其设计流量计算的说法中，哪项不正确？( )",[236,237,238,240],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":239,"correct":32},"航站楼、影剧院建筑属于用水分散型建筑",{"key":30,"text":241,"correct":22},"中学学生宿舍属于用水集中型建筑",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":24,"analysis":33},878904,"选择游泳池循环给水方式的叙述中，哪项是错误的？( )",[246,248,250,252],{"key":20,"text":247,"correct":22},"顺流式循环给水方式不再适用于竞赛游泳池",{"key":24,"text":249,"correct":32},"游泳池采用混流式循环给水方式时，宜设置平衡水池",{"key":27,"text":251,"correct":22},"游泳池宜按池水连续24h循环进行设计",{"key":30,"text":253,"correct":22},"游乐池池水水面标高不同的多个池子共用一个循环净化系统时，各池进水管上应设控制阀门。",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":27,"analysis":33},878905,"下列建筑排水管最小管径的要求中，哪一项是正确的？( )",[258,260,262,264],{"key":20,"text":259,"correct":22},"建筑内排出管最小管径不得小于75mm",{"key":24,"text":261,"correct":22},"公共食堂厨房污水排水支管管径不得小于100mm",{"key":27,"text":263,"correct":32},"医院污水盆排水管管径不得小于75mm",{"key":30,"text":265,"correct":22},"小便槽的排水支管管径不得小于100mm",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":24,"analysis":33},878906,"当天沟水深完全淹没雨水斗时，单斗雨水系统内出现最大负压值(-)与最大正压值(+)的部位应为下列哪一项？( )",[270,272,274,276],{"key":20,"text":271,"correct":22},"(-)：立管与埋地管连接处；(+)：悬吊管与立管连接处",{"key":24,"text":273,"correct":32},"(-)：悬吊管与立管连接处；(+)：立管与埋地管连接处；",{"key":27,"text":275,"correct":22},"(-)：雨水斗入口处；(+)：立管与埋地管连接处；",{"key":30,"text":277,"correct":22},"(-)：雨水斗入口处；(+)：连接管与悬吊管连接处；",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":30,"analysis":33},878907,"下列关于建筑屋面压力流雨水排水系统Ⅰ和重力流雨水排水系统Ⅱ二者异、同的叙述中，哪一项是不确切的？( )",[282,284,286,288],{"key":20,"text":283,"correct":22},"Ⅰ悬吊管可水平敷设，而Ⅱ悬吊管应有坡度",{"key":24,"text":285,"correct":22},"Ⅰ立管管径可小于悬吊管管径，而Ⅱ立管管径不得小于悬吊管管径",{"key":27,"text":287,"correct":22},"在有埋地排出管时，Ⅰ和Ⅱ的雨水立管底部均应设清扫口",{"key":30,"text":289,"correct":32},"多层建筑Ⅰ和Ⅱ的管材均应采用承压塑料排水管",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":292,"answer":27,"analysis":33},878908,[293,294,295,296],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":32},{"key":30,"text":33,"correct":22},{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":299,"answer":27,"analysis":33},878909,[300,301,302,303],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":32},{"key":30,"text":33,"correct":22},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":27,"analysis":33},878910,"二氧化碳灭火器的使用温度范围是下列哪项？( )",[308,310,312,314],{"key":20,"text":309,"correct":22},"5～55℃",{"key":24,"text":311,"correct":22},"0～55℃",{"key":27,"text":313,"correct":32},"-10～55℃",{"key":30,"text":315,"correct":22},"-20～55℃",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":318,"answer":30,"analysis":33},878911,[319,321,323,325],{"key":20,"text":320,"correct":22},"a、b合一循环系统，c、d设独立循环系统",{"key":24,"text":322,"correct":22},"a、b、c合一循环系统，d设独立循环系统",{"key":27,"text":324,"correct":22},"b、c合一循环系统，a、d设独立循环系统",{"key":30,"text":326,"correct":32},"a、b、c、d均设独立循环系统",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":20,"analysis":33},878912,"下列关于开水和热水管材的选用要求中，何项是不正确的？( )",[331,333,335,337],{"key":20,"text":332,"correct":32},"开水管道应选择许用工作温度大于100℃的塑料管材",{"key":24,"text":334,"correct":22},"定时供应热水系统不宜选用塑料热水管",{"key":27,"text":336,"correct":22},"热水供应系统中设备机房内的管道不应采用塑料热水管",{"key":30,"text":338,"correct":22},"热水管道可采用薄壁钢管、薄壁不锈钢管、塑料与金属的复合热水管",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":341,"answer":30,"analysis":33},878913,[342,344,346,348],{"key":20,"text":343,"correct":22},"容积式水加热器",{"key":24,"text":345,"correct":22},"半容积式水加热器",{"key":27,"text":347,"correct":22},"导流型容积式水加热器",{"key":30,"text":349,"correct":32},"半即热式水加热器",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":24,"analysis":33},878914,"某建筑高度为49m的二类建筑商业楼设有室内外消火栓及自动喷水灭火系统，其中自动喷水灭火系统的用水量为30L\u002Fs，该建筑室内、室外消火栓用水量应为下列何项？( )",[354,356,358,360],{"key":20,"text":355,"correct":22},"室内、室外消火栓均为15L\u002Fs",{"key":24,"text":357,"correct":32},"室内、室外消火栓均为20L\u002Fs",{"key":27,"text":359,"correct":22},"室内消火栓为15L\u002Fs，室外消火栓为20L\u002Fs",{"key":30,"text":361,"correct":22},"室内消火栓为20L\u002Fs，室外消火栓为15L\u002Fs",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":30,"analysis":33},878915,"选择建筑排水系统时，下列哪项必须考虑？( )",[366,368,370,372],{"key":20,"text":367,"correct":22},"建筑功能",{"key":24,"text":369,"correct":22},"卫生器具",{"key":27,"text":371,"correct":22},"排水出路",{"key":30,"text":373,"correct":32},"排水水质",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":27,"analysis":33},878916,"以下有关全日制集中热水供应系统管道流速、流量、和循环流量的叙述中，哪项不正确？( )",[378,380,382,384],{"key":20,"text":379,"correct":22},"生活热水管道中流速的控制应小于同管径生活给水管道的流速",{"key":24,"text":381,"correct":22},"热水供水管网中循环流量循环的作用是补偿热水配水管的热损失",{"key":27,"text":383,"correct":32},"热水供水管网中循环流量循环的作用是补偿热水配水管和回水管的热损失",{"key":30,"text":385,"correct":22},"建筑生活热水配水管和生活给水管设计秒流量的计算方法相同",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":24,"analysis":33},878917,"下列有关建筑中水系统水量平衡措施的描述，哪项错误？( )",[390,392,394,396],{"key":20,"text":391,"correct":22},"原水调节池是用来调节原水量与处理量之间水量平衡的",{"key":24,"text":393,"correct":32},"溢流会造成水的浪费，故选择水量平衡措施时不得采用溢流的方式",{"key":27,"text":395,"correct":22},"通过自动控制合理调整处理设备的运行时间是水量平衡措施之一",{"key":30,"text":397,"correct":22},"中水贮水池设置自来水补水管也是水量平衡措施之一",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":24,"analysis":33},878918,"下列哪项游泳池宜采用全流量半程式臭氧辅以氯的消毒系统？( )",[402,404,406,408],{"key":20,"text":403,"correct":22},"训练游泳池",{"key":24,"text":405,"correct":32},"竞赛游泳池",{"key":27,"text":407,"correct":22},"会员制游泳池",{"key":30,"text":409,"correct":22},"私人游泳池",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":30,"analysis":33},878919,"水喷雾灭火系统采用的报警阀，应是下列哪种类型？( )",[414,416,418,420],{"key":20,"text":415,"correct":22},"湿式报警阀",{"key":24,"text":417,"correct":22},"干式报警阀",{"key":27,"text":419,"correct":22},"预作用报警阀",{"key":30,"text":421,"correct":32},"雨淋报警阀",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":24,"analysis":33},878920,"关于灭火设施设置场所火灾危险等级分类、分级的叙述中，何项不正确？( )",[426,428,430,432],{"key":20,"text":427,"correct":22},"工业厂房应根据生产中使用或产生的物质性质及其数量等因素，分为甲、乙、丙、丁、戊类",{"key":24,"text":429,"correct":32},"多层民用建筑应根据使用性质、火灾危险性、疏散及扑救难度分为一类和二类",{"key":27,"text":431,"correct":22},"自动喷水灭火系统设置场所分为轻危险级、中危险级、严重危险级和仓库危险级",{"key":30,"text":433,"correct":22},"民用建筑灭火器配置场所分为轻危险级、中危险级和严重危险级",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":20,"analysis":33},878921,"饮用水制备一般不推荐采用反渗透处理工艺，下列关于其原因的叙述中，哪项说法错误？( )",[438,440,442,444],{"key":20,"text":439,"correct":32},"设备价格高",{"key":24,"text":441,"correct":22},"水的回收率低",{"key":27,"text":443,"correct":22},"工作压力大，能耗大",{"key":30,"text":445,"correct":22},"截留有益于健康的物质",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":27,"analysis":33},878922,"某宾馆公共游泳池分为成人区和儿童区，每日开放10h，下列关于该游泳池池水循环净水系统的设计，哪项正确？( )",[450,452,454,456],{"key":20,"text":451,"correct":22},"游泳池成人区、儿童区共用循环系统，每天循环次数为7次",{"key":24,"text":453,"correct":22},"游泳池成人区、儿童区共用循环系统，每天循环次数为5次",{"key":27,"text":455,"correct":32},"游泳池成人区、儿童区分设循环系统，每天循环次数分别为2次、5次",{"key":30,"text":457,"correct":22},"游泳池成人区、儿童区分设循环系统，每天循环次数分别为1次、5次",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":24,"analysis":33},878923,"消火栓、消防水炮、自动喷水系统灭火机理主要是下列哪项？( )",[462,464,466,468],{"key":20,"text":463,"correct":22},"窒息",{"key":24,"text":465,"correct":32},"冷却",{"key":27,"text":467,"correct":22},"乳化",{"key":30,"text":469,"correct":22},"稀释",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":20,"analysis":33},878924,"下列关于建筑生活排水系统的表述，哪项正确？( )",[474,476,478,480],{"key":20,"text":475,"correct":32},"居住小区生活排水定额小于其生活给水定额",{"key":24,"text":477,"correct":22},"是否适当放大排水管径，应通过排水水力计算确定",{"key":27,"text":479,"correct":22},"塑料排水横支管的标准坡度由管道中的水流速度决定",{"key":30,"text":481,"correct":22},"小区生活排水系统小时变化系数小于其相应的生活给水系统小时变化系数",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":30,"analysis":33},878925,"有关建筑排水定额，小时变化系数和小时排水量的叙述中，错误的是何项？( )",[486,488,490,492],{"key":20,"text":487,"correct":22},"建筑内部生活排水定额和小时变化系数与其相应的建筑给水相同",{"key":24,"text":489,"correct":22},"建筑内部生活排水平均时和最大时排水量的计算方法与建筑给水相同",{"key":27,"text":491,"correct":22},"公共建筑生活排水定额和小时变化系数与公共建筑生活用水定额和小时变化系数相同",{"key":30,"text":493,"correct":32},"居住小区生活排水系统的排水定额和小时定额系数是其相应生活给水系数的给水定额和小时变化系数的85%～95%",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":20,"analysis":33},878926,"下列高层建筑消火栓系统竖管设置的技术要求中，哪一项是正确的？( )",[498,500,502,504],{"key":20,"text":499,"correct":32},"消防竖管最小管径不应小于100mm是基于利用水泵接合器补充室内消防用水的需要",{"key":24,"text":501,"correct":22},"消防竖管布置应保证同层两个消火栓水枪的充实水柱同时到达被保护范围内的任何部位",{"key":27,"text":503,"correct":22},"消防竖管检修时应保证关闭停用的竖管不超过1根，当竖管超过4根时可关闭2根",{"key":30,"text":505,"correct":22},"当设2根消防竖管有困难时，可设1根竖管，但必须采用双阀双出口型消火栓",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":27,"analysis":33},878927,"下列关于灭火器配置设计的叙述中，哪项不正确？( )",[510,512,514,516],{"key":20,"text":511,"correct":22},"9层及以下的住宅建筑可不配置灭火器",{"key":24,"text":513,"correct":22},"选择灭火器时应考虑其使用人员的体能",{"key":27,"text":515,"correct":32},"同一防火分区内，灭火器的配置设计计算应相同",{"key":30,"text":517,"correct":22},"原木库房灭火器配置场所的危险等级不属于中危险级和严重危险级",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":30,"analysis":33},878928,"下列有关建筑生活排水局部处理设施的说法中，哪项不正确或欠合理？( )",[522,524,526,528],{"key":20,"text":523,"correct":22},"当建筑物内采用生活污，废分流制排水系统时，可减小化粪池的容积",{"key":24,"text":525,"correct":22},"化粪池沉淀部分的构造尺寸理论上可参考平流式沉淀池的计算",{"key":27,"text":527,"correct":22},"采用人工清油的隔油池内存油部分的容积应大于该池有效容积的25%",{"key":30,"text":529,"correct":32},"锅炉房废热水采用降温池处理时，其冷却水最好就近采用锅炉房的自来水",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":24,"analysis":33},878929,"下列关于水喷雾灭火系统喷头选择的说明中，哪项不正确？( )",[534,536,538,540],{"key":20,"text":535,"correct":22},"扑灭电缆火灾的水雾喷头应采用高速喷头",{"key":24,"text":537,"correct":32},"扑灭电缆火灾的水雾喷头应采用工作压力≥0.30MPa的中速喷头",{"key":27,"text":539,"correct":22},"扑灭电气火灾的水雾喷头应采用离心雾化喷头",{"key":30,"text":541,"correct":22},"用于储油罐防护冷却用的水雾喷头宜采用中速型喷头",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":27,"analysis":33},878930,"某大型机场航站楼屋面雨水排水工程与溢流设施的总排水能力不应小于多少年暴雨设计重现期的雨水量？( )",[546,548,550,552],{"key":20,"text":547,"correct":22},"10年",{"key":24,"text":549,"correct":22},"20年",{"key":27,"text":551,"correct":32},"50年",{"key":30,"text":553,"correct":22},"100年",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":30,"analysis":33},878931,"下列关于雨水利用系统选型，哪项错误？( )",[558,560,562,564],{"key":20,"text":559,"correct":22},"地面雨水宜采用雨水入渗",{"key":24,"text":561,"correct":22},"屋面雨水用于景观水体补水时，雨水经初期径流弃流后可不加水质处理而进入水体",{"key":27,"text":563,"correct":22},"大型屋面的公共建筑，屋面雨水宜采用收集回用系统",{"key":30,"text":565,"correct":32},"雨水调蓄排放可削减小区外排雨水径流总量",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":20,"analysis":33},878932,"下列关于建筑生活热水供应系统的说法中，哪项不正确？( )",[570,572,574,576],{"key":20,"text":571,"correct":32},"设计小时供热量=设计小时耗热量",{"key":24,"text":573,"correct":22},"一般情况下，冷热水温差越大，设计小时耗热量越大",{"key":27,"text":575,"correct":22},"容积式水加热器贮热容积越大，所需设计小时供热量越小",{"key":30,"text":577,"correct":22},"无储热容积的水加热器，其设计小时供热量为设计秒流量所需耗热量",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":30,"analysis":33},878933,"下列有关建筑热水供应系统的说法中，哪项错误？( )",[582,584,586,588],{"key":20,"text":583,"correct":22},"局部热水供应系统是供给单个或数个配水点所需热水的热水供应系统",{"key":24,"text":585,"correct":22},"集中热水供应系统是供给单栋(不含别墅)或数栋建筑所需热水的热水供应系统",{"key":27,"text":587,"correct":22},"区域热水供应系统是供给数个居民区或工业企业等所需热水的热水供应系统",{"key":30,"text":589,"correct":32},"上述热水供应系统均须设置热水循环管道",{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":24,"analysis":33},878934,"《建筑设计防火规范》规定室内消防竖管直径不应小于DN100，下述哪一项作为特殊情况，其消防竖管直径可以小于DN100？( )",[594,596,598,600],{"key":20,"text":595,"correct":22},"设置DN65消火栓的多层住宅的湿式消防竖管",{"key":24,"text":597,"correct":32},"设置DN65消火栓的多层住宅的干式消防竖管",{"key":27,"text":599,"correct":22},"室内消火栓用水量为5L\u002Fs的多层厂房的消防竖管",{"key":30,"text":601,"correct":22},"室内消火栓用水量为5L\u002Fs的多层仓库的消防竖管",[603,606,609,612,615,618],{"id":15,"name":604,"category":7,"favorite":605},"领导干部任职前廉政法规知识测试题",92,{"id":607,"name":608,"category":7,"favorite":15},595,"建筑结构与设备",{"id":610,"name":611,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":613,"name":614,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":616,"name":617,"category":7,"favorite":8},534,"BIM工程师",{"id":619,"name":617,"category":7,"favorite":8},535]