[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-568-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":616},{"id":5,"name":6,"category":7,"favorite":8},568,"专业知识（给排水）","建筑工程",0,5,50,1213,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,334,344,356,367,379,391,403,415,427,439,451,463,474,486,498,510,522,534,546,558,570,581,592,604],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},878833,1,"单选题","下列关于平流沉淀池中雷诺数Re、弗劳德数Fr的大小对沉淀影响的叙述中，哪项正确？( )",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","雷诺数Re较大的水流可以促使絮凝体颗粒相互碰撞凝结，故认为沉淀池中水流的雷诺数Re越大越好",false,{"key":24,"text":25,"correct":22},"B","弗劳德数Fr较小的水流流速较慢，沉淀时间增长，杂质去除率高，故认为沉淀池中水流的弗劳德数Fr越小越好",{"key":27,"text":28,"correct":22},"C","增大过水断面湿周，可同时增大雷诺数，减小弗劳德数，有利于提高杂质沉淀去除效果",{"key":30,"text":31,"correct":32},"D","增大水平流速有助于减小水温差、密度差异重流的影响",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},878834,"下列哪项不属于给水系统或给水系统的组成部分？( )",[38,40,42,44],{"key":20,"text":39,"correct":32},"泉水",{"key":24,"text":41,"correct":22},"泉水泵房",{"key":27,"text":43,"correct":22},"泉室",{"key":30,"text":45,"correct":22},"南水北调工程",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},878835,"下列关于城市用水量变化曲线的说法中，哪项正确？( )",[50,52,54,56],{"key":20,"text":51,"correct":32},"每一天都有一条用水量变化曲线",{"key":24,"text":53,"correct":22},"用水量变化曲线的变化幅度与当地气候无关",{"key":27,"text":55,"correct":22},"城市越大，用水量变化曲线的变化幅度越大",{"key":30,"text":57,"correct":22},"水厂清水池调节容积应根据二级泵站供水曲线与用水量变化曲线确定",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},878836,"城镇供水的两条平行输水管线之前的连通管的根数以及输水干管的管径，应按照输水干管任何一段发生故障时，仍能通过设计水量的一定比例计算确定，下列哪项比例(%)正确？( )",[62,64,66,68],{"key":20,"text":63,"correct":22},"50",{"key":24,"text":65,"correct":22},"60",{"key":27,"text":67,"correct":32},"70",{"key":30,"text":69,"correct":22},"80",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},878837,"下列有关输水干管设计的叙述中，哪项正确？( )",[74,76,78,80],{"key":20,"text":75,"correct":22},"输水干管必须设计两根及两根以上",{"key":24,"text":77,"correct":22},"输水干管发生事故时，该干管必须满足设计水量的70%",{"key":27,"text":79,"correct":32},"两条输水干管连通管越多，事故时供水保证率越高",{"key":30,"text":81,"correct":22},"重力输水的输水管穿越河道必须采用从河底穿越方式",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},878838,"下述一般情况下，地下水与地表水相比所具有的特点中，哪一项是错误的？( )",[86,88,90,92],{"key":20,"text":87,"correct":22},"矿化度比地表水高",{"key":24,"text":89,"correct":32},"水温比地表水低",{"key":27,"text":91,"correct":22},"水量季节性变化比地表水小",{"key":30,"text":93,"correct":22},"净水工艺较地表水简单",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},878839,"在合理开发和利用水源所采取的主要措施方面，下列哪项表述不正确？( )",[98,100,102,104],{"key":20,"text":99,"correct":22},"当某地区同时可取用地表和地下水源时，地下水源应优先考虑用于生活饮用水源",{"key":24,"text":101,"correct":32},"承压地下水其上覆盖有不透水层，可防渗透污染，水质稳定且卫生条件较好，应首先确定用于给水水源",{"key":27,"text":103,"correct":22},"在工业用水中，应尽量采用循环给水系统，以提水的重复利用率",{"key":30,"text":105,"correct":22},"采用人工回灌技术，利用地表水补充地下水，可保持地下水源开采和补给水量的平衡",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},878840,"天然胶体中，胶体颗粒能长期处于聚集稳定状态，其主要原因是颗粒间下述哪种力的作用？( )",[110,112,114,116],{"key":20,"text":111,"correct":22},"范德华引力",{"key":24,"text":113,"correct":32},"静电斥力",{"key":27,"text":115,"correct":22},"重力",{"key":30,"text":117,"correct":22},"浮力",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":30,"analysis":33},878841,"某农村地下水质含铁7.0mg\u002FL、含锰2.0mg\u002FL，无试验条件验证除铁除锰工艺，此时采用下列哪项除铁除锰工艺比较可靠？( )",[122,124,126,128],{"key":20,"text":123,"correct":22},"一级自然氧化过滤",{"key":24,"text":125,"correct":22},"一级催化氧化过滤",{"key":27,"text":127,"correct":22},"两级曝气一级过滤",{"key":30,"text":129,"correct":32},"一级曝气两级过滤",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},878842,"下列有关空气湿球温度τ，干球温度θ对水冷却的影响叙述中，哪项错误？( )",[134,136,138,140],{"key":20,"text":135,"correct":22},"干球温度θ代表水表面上空气的温度",{"key":24,"text":137,"correct":32},"湿球温度τ代表水面上空气中水蒸气的温度",{"key":27,"text":139,"correct":22},"当水的温度等于干球温度θ时，只能发生蒸发传热冷却",{"key":30,"text":141,"correct":22},"当水的温度等于湿球温度τ时，水不再冷却",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},878843,"在湿式冷却塔内的任一部位，空气与水之间热量交换的推动力为下列哪项？( )",[146,148,150,152],{"key":20,"text":147,"correct":22},"水与气的温差值",{"key":24,"text":149,"correct":32},"饱和空气焓与空气焓差值",{"key":27,"text":151,"correct":22},"水的饱和蒸汽与空气的水蒸气的压差值",{"key":30,"text":153,"correct":22},"饱和空气与空气的压差值",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},878844,"某大型工业循环冷却水的菌藻处理采用以加液氯为主，则辅助投加的杀菌灭藻剂宜采用以下哪种？( )",[158,160,162,164],{"key":20,"text":159,"correct":22},"臭氧",{"key":24,"text":161,"correct":32},"硫酸铜",{"key":27,"text":163,"correct":22},"次氯酸钠",{"key":30,"text":165,"correct":22},"二氧化氯",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":30,"analysis":33},878845,"某24h连续运行的以湖泊为水源的城镇给水系统的流程为：原水→水厂→供水输水管→网前高地水池→配水总管→管网，上述组成中设计流量最大的是下列哪项？( )",[170,172,174,176],{"key":20,"text":171,"correct":22},"原水输水管",{"key":24,"text":173,"correct":22},"水厂二级泵房",{"key":27,"text":175,"correct":22},"清水输水管",{"key":30,"text":177,"correct":32},"配水总管",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":24,"analysis":33},878846,"下列有关完整式大口井的描述，哪项不准确？( )",[182,184,186,188],{"key":20,"text":183,"correct":22},"为减少施工时井壁下沉时阻力，可采用阶梯圆形井筒",{"key":24,"text":185,"correct":32},"可采用井底进水方式",{"key":27,"text":187,"correct":22},"出水量可采用同条件下的管井出水量计算公式",{"key":30,"text":189,"correct":22},"适用于含水层厚度5m左右",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":24,"analysis":33},878847,"在给水系统中，下列哪项不属于调节构筑物？( )",[194,196,198,200],{"key":20,"text":195,"correct":22},"清水池",{"key":24,"text":197,"correct":32},"二级泵站吸水井",{"key":27,"text":199,"correct":22},"网前水塔",{"key":30,"text":201,"correct":22},"与管网连接的高位水池",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":27,"analysis":33},878848,"下列关于生活饮用水地下水源的卫生防护措施中，哪项不恰当？( )",[206,208,210,212],{"key":20,"text":207,"correct":22},"在取水井的影响半径范围内，不得使用生活污水灌溉",{"key":24,"text":209,"correct":22},"在取水井的影响半径范围内，不得使用有剧毒的农药",{"key":27,"text":211,"correct":32},"在取水井的影响半径范围内，不得修建厕所和铺设污水管道",{"key":30,"text":213,"correct":22},"在取水井的影响半径范围内，不得堆放垃圾、粪便和废渣",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":20,"analysis":33},878849,"下列有关山区浅水河流取水构筑物的形式和设计要求中，正确的是何项？( )",[218,220,222,224],{"key":20,"text":219,"correct":32},"取水构筑物的形式可以有低坝式、底栏栅式、大口井和渗渠",{"key":24,"text":221,"correct":22},"底栏栅式取水构筑物宜建在河流出口以下冲积扇河段上",{"key":27,"text":223,"correct":22},"底栏栅式取水构筑物的栏栅间隙宽度取决于河道比降、洪水流量等因素",{"key":30,"text":225,"correct":22},"低坝式取水构筑物的坝高应满足设计对枯水流量的要求",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":24,"analysis":33},878850,"某养老院建筑内部的某排水横管上接纳了1个洗脸盆和1个淋浴器，则该排水横管的设计秒流量(L\u002Fs)为以下哪项？( )",[230,232,234,236],{"key":20,"text":231,"correct":22},"0.45",{"key":24,"text":233,"correct":32},"0.40",{"key":27,"text":235,"correct":22},"0.35",{"key":30,"text":237,"correct":22},"0.20",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":24,"analysis":33},878851,"下面关于建筑屋面雨水排水系统设计的说法中，哪项错误？( )",[242,244,246,248],{"key":20,"text":243,"correct":22},"屋面雨水排水工程应设置溢流设施",{"key":24,"text":245,"correct":32},"采用重力流的屋面雨水排水系统应按满流设计",{"key":27,"text":247,"correct":22},"采用满管压力流的屋面雨水排水系统，在雨水初期按重力流排水复核计算",{"key":30,"text":249,"correct":22},"对同一建筑屋面，其屋面雨水可分别采用重力流和满管压力流雨水排水系统",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":30,"analysis":33},878852,"某办公楼的4～10层采用二次加压供水系统，加压泵前设贮水设施，由环状市政供水管接管补水，市政给水补水满足加压供水管网设计秒流量的供水要求，则贮水设施的有效容积按下列哪项确定是正确合理的？( )",[254,256,258,260],{"key":20,"text":255,"correct":22},"按最高日用水量的20%计算",{"key":24,"text":257,"correct":22},"按最高日用水量的25%计算",{"key":27,"text":259,"correct":22},"按最高日用水量的50%计算",{"key":30,"text":261,"correct":32},"按5min水泵设计秒流量计算",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":27,"analysis":33},878853,"计算集中热水供应系统的贮热容积时，采用哪种水加热器或贮水器可不计算附加容积？( )",[266,268,270,272],{"key":20,"text":267,"correct":22},"水源热泵热水系统的贮热水箱",{"key":24,"text":269,"correct":22},"导流型容积式水加热器",{"key":27,"text":271,"correct":32},"半容积式水加热器",{"key":30,"text":273,"correct":22},"空气源热泵热水系统的贮热水罐",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":27,"analysis":33},878854,"某二层乙类厂房(层高6.6m)设有室内消火栓给水系统，则其消火栓水枪的充实水柱长度不应小于下列哪项？( )",[278,280,282,284],{"key":20,"text":279,"correct":22},"7m",{"key":24,"text":281,"correct":22},"13m",{"key":27,"text":283,"correct":32},"10m",{"key":30,"text":285,"correct":22},"8m",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":24,"analysis":33},878855,"某小区的车行道、绿地下均敷设给水管道.地坪标高均按-3.0m计，土壤冰冻深度为0.5m。则下列哪项错误？( )",[290,292,294,296],{"key":20,"text":291,"correct":22},"车行道下给水管的管顶标高不得高于-3.65m",{"key":24,"text":293,"correct":32},"车行道下给水管的管顶覆土厚度不得小于0.70m",{"key":27,"text":295,"correct":22},"绿地下给水管的管顶标高不得高于-3.65m",{"key":30,"text":297,"correct":22},"绿地下给水管的管顶覆土厚度不得小于0.65m",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":20,"analysis":33},878856,"下列建筑给水系统设计，哪项可行？( )",[302,304,306,308],{"key":20,"text":303,"correct":32},"住宅小区支状生活给水管网的引入管上未设置倒流防止器",{"key":24,"text":305,"correct":22},"水池侧壁进水的生活饮用水进水管口最低点高于水池最高设计水位",{"key":27,"text":307,"correct":22},"利用市政水压叠压供水时，仅在水泵的出水管上设置止回阀",{"key":30,"text":309,"correct":22},"游泳池淹没补水管上设置倒流防止器",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":30,"analysis":33},878857,"采用半即热式水加热器的机械循环热水供应系统中，循环水泵的扬程依据下列何项确定？( )",[314,316,318,320],{"key":20,"text":315,"correct":22},"满足热水供应系统最不利配水点最低工作压力的需求",{"key":24,"text":317,"correct":22},"循环流量通过配水管网的水头损失",{"key":27,"text":319,"correct":22},"循环流量通过配水、回水管网的水头损失",{"key":30,"text":321,"correct":32},"循环流量通过配水、回水管网和加热设备的水头损失",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":30,"analysis":33},878858,"下列关于小区埋地给水管道的设置要求中，哪项不正确？( )",[326,328,330,332],{"key":20,"text":327,"correct":22},"小区给水管道与污水管道交叉时应敷设在污水管道上方，否则应设钢套管且套管两端用防水材料封闭",{"key":24,"text":329,"correct":22},"小区生活给水管道的覆土深度不得小于冰冻线以下0.15m，否则应做保温处理",{"key":27,"text":331,"correct":22},"给水管道敷设在绿地下且无防冻要求时，覆土深度可小于0.5m",{"key":30,"text":333,"correct":32},"小区给水管道距污水管的水平净距不得小于0.8m",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":20,"analysis":33},878859,"下列何项不符合集中热水供应系统的设计要求？( )",[338,339,340,342],{"key":20,"text":33,"correct":32},{"key":24,"text":33,"correct":22},{"key":27,"text":341,"correct":22},"可采用按比例将部分软化热水与部分未软化热水均匀混合达到系统水质要求后使用",{"key":30,"text":343,"correct":22},"为减轻对热水管道和设备的腐蚀，可对溶解氧和二氧化碳超标的原水采取除气措施",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":20,"analysis":33},878860,"下列原水水质均符合要求的集中热水供应系统中，加热设备热水出水温度f的选择，哪项是不合理的？( )",[348,350,352,354],{"key":20,"text":349,"correct":32},"浴室供沐浴用热水系统t=40℃",{"key":24,"text":351,"correct":22},"饭店专供洗涤用热水系统t=75℃",{"key":27,"text":353,"correct":22},"住宅生活热水系统t=60℃",{"key":30,"text":355,"correct":22},"招待所供盥洗用热水系统t=55℃",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":20,"analysis":33},878861,"某热水供应系统采用间接加热，热媒供应能力为235600kJ\u002Fh。该建筑的热水设计小时用水量为1200L\u002Fh(热水温度60℃)，配水管网设计秒流量为2.3L\u002Fs。则水加热器宜选用以下哪种型式(冷水温度10℃)？( )",[360,362,363,365],{"key":20,"text":361,"correct":32},"容积式水加热器",{"key":24,"text":271,"correct":22},{"key":27,"text":364,"correct":22},"半即热式水加热器",{"key":30,"text":366,"correct":22},"快速式水加热器",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":27,"analysis":33},878862,"下列有关自动喷水灭火系统操作与控制的叙述中，哪项错误？( )",[371,373,375,377],{"key":20,"text":372,"correct":22},"雨淋阀采用充水传动管自动控制时，闭式喷头和雨淋阀之间的高差应限制",{"key":24,"text":374,"correct":22},"雨淋阀采用充气传动管自动控制时，闭式喷头和雨淋阀之间的高差不受限制",{"key":27,"text":376,"correct":32},"预作用系统自动控制是采用在消防控制室设手动远控方式",{"key":30,"text":378,"correct":22},"闭式系统在喷头动作后，应立即自动启动供水泵向配水管网供水",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":30,"analysis":33},878863,"下列哪项建筑物应设置室内自动喷水灭火系统？( )",[383,385,387,389],{"key":20,"text":384,"correct":22},"高层民用建筑",{"key":24,"text":386,"correct":22},"高层工业建筑",{"key":27,"text":388,"correct":22},"1470座位的普通剧院",{"key":30,"text":390,"correct":32},"建筑面积3200㎡的单层商店",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":20,"analysis":33},878864,"下述浴室热水供应系统的设计中，哪项不符合要求？( )",[395,397,399,401],{"key":20,"text":396,"correct":32},"淋浴器数量较多的公共浴室，应采用单管热水供应系统",{"key":24,"text":398,"correct":22},"单管热水供应系统应有保证热水温度稳定的技术措施",{"key":27,"text":400,"correct":22},"公共浴室宜采用开式热水供应系统以便调节混合水嘴出水温度",{"key":30,"text":402,"correct":22},"连接多个淋浴器的配水管宜连成环状，且其管径应大于20mm",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":20,"analysis":33},878865,"居住小区生活排水流量应按下列哪种方法计算？( )",[407,409,411,413],{"key":20,"text":408,"correct":32},"住宅生活排水最大小时流量+公共建筑生活排水最大小时流量",{"key":24,"text":410,"correct":22},"住宅生活排水设计秒流量+公共建筑生活排水设计秒流量",{"key":27,"text":412,"correct":22},"住宅生活排水平均小时流量+公共建筑生活排水平均小时流量",{"key":30,"text":414,"correct":22},"住宅生活排水最高日平均秒流量+公共建筑生活排水最高日平均秒流量",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":30,"analysis":33},878866,"下列关于中水水质的分析与比较中，哪项不正确？( )",[419,421,423,425],{"key":20,"text":420,"correct":22},"沐浴废水有机物的污染程度：住宅＞宾馆＞公共浴室",{"key":24,"text":422,"correct":22},"同一类建筑生活污废水有机物的污染程度：厨房＞洗衣＞沐浴",{"key":27,"text":424,"correct":22},"综合污水SS的污染程度：营业餐厅＞住宅＞宾馆",{"key":30,"text":426,"correct":32},"生活污水的可生化程度：洗衣＞沐浴＞厨房",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":27,"analysis":33},878867,"下列关于自动喷水灭火系统水平配管上敷设减压孔板的叙述中，哪项正确？( )",[431,433,435,437],{"key":20,"text":432,"correct":22},"在管径DN40mm的配水管上设孔口直径40mm的不锈钢孔板",{"key":24,"text":434,"correct":22},"在管径DN150mm的配水管上设孔口直径40mm的不锈钢孔板",{"key":27,"text":436,"correct":32},"在管径DN100mm的配水管上设孔口直径32mm的不锈钢孔板",{"key":30,"text":438,"correct":22},"在管径DN100mm的配水管上设孔口直径32mm的碳钢孔板",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":30,"analysis":33},878868,"下列关于建筑灭火器配置设计的叙述中，哪项错误？( )",[443,445,447,449],{"key":20,"text":444,"correct":22},"灭火器可布置在楼梯间内",{"key":24,"text":446,"correct":22},"同一场所可配置两种以上类型灭火器，但其灭火剂应相容",{"key":27,"text":448,"correct":22},"灭火器的保护距离是指设置点到最不利点的直线行走距离",{"key":30,"text":450,"correct":32},"轻危险级场所应保证每个计算单元至少有一具灭火器保护",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":30,"analysis":33},878869,"油浸电力变压器采用水喷雾灭火时，下列哪项不起作用？( )",[455,457,459,461],{"key":20,"text":456,"correct":22},"表面冷却",{"key":24,"text":458,"correct":22},"窒息",{"key":27,"text":460,"correct":22},"乳化",{"key":30,"text":462,"correct":32},"稀释",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":465,"answer":30,"analysis":33},878870,[466,468,470,472],{"key":20,"text":467,"correct":22},"喷头公称动作温度取68℃",{"key":24,"text":469,"correct":22},"消火栓水枪的充实水柱不小于13m",{"key":27,"text":471,"correct":22},"计算室内消防用水量时，消火栓系统用水量不小于10L\u002Fs",{"key":30,"text":473,"correct":32},"自动喷水灭火系统的作用面积和喷水强度分别不小于160㎡和6L\u002F(min·㎡)",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":30,"analysis":33},878871,"某锅炉房设置水喷雾灭火系统进行灭火，其喷头的工作压力应采用下列哪项数值？( )",[478,480,482,484],{"key":20,"text":479,"correct":22},"0.1MPa",{"key":24,"text":481,"correct":22},"0.2MPa",{"key":27,"text":483,"correct":22},"0.3MPa",{"key":30,"text":485,"correct":32},"0.4MPa",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":20,"analysis":33},878872,"请判断油浸电力变压器设置水喷雾灭火系统时，下述各项设计技术要求中哪一项是错误的？( )",[490,492,494,496],{"key":20,"text":491,"correct":32},"系统应采用撞击型水雾喷头，其工作压力应不小于0.35MPa",{"key":24,"text":493,"correct":22},"水雾喷头应布置在变压器的周围，不宜布置在变压器顶部",{"key":27,"text":495,"correct":22},"系统应设置自动控制、手动控制和应急操作三种控制方式",{"key":30,"text":497,"correct":22},"系统应采用雨淋阀，阀前管道应设置过滤器",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":24,"analysis":33},878873,"以下哪项不宜作为建筑物中水系统的水源？( )",[502,504,506,508],{"key":20,"text":503,"correct":22},"盥洗排水",{"key":24,"text":505,"correct":32},"室外雨水",{"key":27,"text":507,"correct":22},"游泳池排水",{"key":30,"text":509,"correct":22},"空调冷却系统排水",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":24,"analysis":33},878874,"某净空高度为8m的自选商场，设有集中采暖空调系统，选择下述哪种自动喷水灭火系统类型为正确合理？( )",[514,516,518,520],{"key":20,"text":515,"correct":22},"预作用系统",{"key":24,"text":517,"correct":32},"湿式系统",{"key":27,"text":519,"correct":22},"雨淋系统",{"key":30,"text":521,"correct":22},"干式系统",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":24,"analysis":33},878875,"以下哪项不是游泳池循环水工艺所必要的净化处理？( )",[526,528,530,532],{"key":20,"text":527,"correct":22},"过滤",{"key":24,"text":529,"correct":32},"加热",{"key":27,"text":531,"correct":22},"消毒",{"key":30,"text":533,"correct":22},"加药",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":30,"analysis":33},878876,"下列关于游泳池池水循环净化工艺的说法中，哪项不正确？( )",[538,540,542,544],{"key":20,"text":539,"correct":22},"硅藻土过滤为低速过滤",{"key":24,"text":541,"correct":22},"硅藻土过滤可免投混凝剂",{"key":27,"text":543,"correct":22},"儿童游泳池的循环周期不应大于2h",{"key":30,"text":545,"correct":32},"石英砂过滤器宜采用气、水组合反冲洗",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":30,"analysis":33},878877,"下列关于自动喷水灭火系统局部应用的说明中，哪一项是错误的？( )",[550,552,554,556],{"key":20,"text":551,"correct":22},"采用K=80的喷头且其总数为20只时，可不设报警阀组",{"key":24,"text":553,"correct":22},"采用K=115的喷头且其总数为10只时，可不设报警阀组",{"key":27,"text":555,"correct":22},"在采取防止污染生活用水的措施后可由城市供水管直接供水",{"key":30,"text":557,"correct":32},"当采用加压供水时，可按二级负荷供电，且可不设备用泵",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":24,"analysis":33},878878,"一个计算单元内配置的灭火器数量不应少于几具？( )",[562,564,566,568],{"key":20,"text":563,"correct":22},"1具",{"key":24,"text":565,"correct":32},"2具",{"key":27,"text":567,"correct":22},"3具",{"key":30,"text":569,"correct":22},"4具",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":572,"answer":27,"analysis":33},878879,[573,575,577,579],{"key":20,"text":574,"correct":22},"系统的平均时用水量",{"key":24,"text":576,"correct":22},"系统的最高日用水量",{"key":27,"text":578,"correct":32},"系统的最大时用水量",{"key":30,"text":580,"correct":22},"系统的设计秒流量",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":27,"analysis":33},878880,"中药材库房配置手提式灭火器，它的最大保护距离为以下何值？( )",[585,586,588,590],{"key":20,"text":283,"correct":22},{"key":24,"text":587,"correct":22},"15m",{"key":27,"text":589,"correct":32},"20m",{"key":30,"text":591,"correct":22},"25m",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":30,"analysis":33},878881,"下列有关建筑中水的叙述中，哪项错误？( )",[596,598,600,602],{"key":20,"text":597,"correct":22},"中水的水量平衡是针对平均日用水量进行计算",{"key":24,"text":599,"correct":22},"中水供应设施的水池(箱)调节容积应按最高日用水量设计",{"key":27,"text":601,"correct":22},"中水供水系统和中水设施的自来水补水管道上均应设计量装置",{"key":30,"text":603,"correct":32},"中水原水和处理设施出水满足系统最高日用水量时可不设补水设施",{"id":605,"libraryId":5,"type":15,"typeLabel":16,"stem":606,"options":607,"answer":30,"analysis":33},878882,"以下关于室内消火栓设置的叙述中，哪项不准确？( )",[608,610,612,614],{"key":20,"text":609,"correct":22},"消防电梯前室应设消火栓",{"key":24,"text":611,"correct":22},"消火栓应设置在明显且易于操作的部位",{"key":27,"text":613,"correct":22},"消火栓栓口处的出水压力大于0.5MPa时，应设置减压设施",{"key":30,"text":615,"correct":32},"采用临时高压给水方式的室内每个消火栓处均应设置消防启动按钮",[617,620,623,626,629,632],{"id":15,"name":618,"category":7,"favorite":619},"领导干部任职前廉政法规知识测试题",92,{"id":621,"name":622,"category":7,"favorite":15},595,"建筑结构与设备",{"id":624,"name":625,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":627,"name":628,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":630,"name":631,"category":7,"favorite":8},534,"BIM工程师",{"id":633,"name":631,"category":7,"favorite":8},535]