[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-568-4":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":615},{"id":5,"name":6,"category":7,"favorite":8},568,"专业知识（给排水）","建筑工程",0,4,50,1213,[13,34,46,54,65,77,89,101,113,125,137,149,160,172,184,196,208,220,232,244,256,268,279,291,303,315,327,339,351,363,375,387,399,411,423,435,447,459,471,483,495,507,519,531,543,555,567,579,591,603],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},878783,1,"单选题","下列有关斜管沉淀池构造特点和设计要求的叙述中，哪项正确？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","斜管沉淀池中斜管有很大的投影面积，进水水质可不受限制",false,{"key":24,"text":25,"correct":26},"B","上向流斜管沉淀池斜管中水流稳定，设计长宽比例尺寸可不受限制",true,{"key":28,"text":29,"correct":22},"C","斜管沉淀池中多边形斜管内径大小和沉淀效果无关",{"key":31,"text":32,"correct":22},"D","斜管沉淀池清水采用集水槽(渠)集水，出水是否均匀和沉淀池底部配水区高度有关","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},878784,"两条同管径、平等敷设的输水管，中间等距离设置连通管，当某段管道发生事故时，其事故水量保证率与下列哪项因素有关？( )",[38,40,42,44],{"key":20,"text":39,"correct":22},"输水管管径",{"key":24,"text":41,"correct":22},"输水管线总长度",{"key":28,"text":43,"correct":22},"输水管工作压力",{"key":31,"text":45,"correct":26},"连通管根数",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":48,"answer":20,"analysis":33},878785,[49,50,51,52],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":22},{"key":31,"text":53,"correct":22},"不能确定",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":31,"analysis":33},878786,"下列关于平流式沉淀池的构造和设计说明中，正确的是哪项？( )",[58,60,62,63],{"key":20,"text":59,"correct":22},"平流式沉淀池长宽比大于4，表示纵向水平流速和横向水平流速之比大于4",{"key":24,"text":61,"correct":22},"平流式沉淀池的宽度大时，可在中间加设隔墙，主要是改变水平流速大小，增加水体稳定性",{"key":28,"text":33,"correct":22},{"key":31,"text":64,"correct":26},"为防止扰动池底积泥，沉淀池进水花墙应在池底积泥泥面上0.30m以上开孔",{"id":66,"libraryId":5,"type":15,"typeLabel":16,"stem":67,"options":68,"answer":28,"analysis":33},878787,"某小镇设有一座自来水、一套给水管网和一座网后水塔。下列对其二级泵房设计流量的叙述中，哪项正确？( )",[69,71,73,75],{"key":20,"text":70,"correct":22},"应大于给水系统最高日最大时设计流量",{"key":24,"text":72,"correct":22},"应等于给水系统最高日最大时设计流量",{"key":28,"text":74,"correct":26},"小于给水系统最高日最大时设计流量",{"key":31,"text":76,"correct":22},"应等于给水系统最高日平均时设计流量",{"id":78,"libraryId":5,"type":15,"typeLabel":16,"stem":79,"options":80,"answer":28,"analysis":33},878788,"胶体颗粒表面的ξ电位在胶体的稳定与凝聚中起着重要作用，下面关于ξ电位值的叙述何项是正确的？( )",[81,83,85,87],{"key":20,"text":82,"correct":22},"胶体表面的ξ电位在数值上等于胶核表面的总电位",{"key":24,"text":84,"correct":22},"胶体表面的ξ电位在数值上等于吸附层中电荷离子所带电荷总和",{"key":28,"text":86,"correct":26},"胶体表面的ξ电位在数值上等于胶团扩散层中电荷离子所带电荷总和",{"key":31,"text":88,"correct":22},"胶体表面的ξ电位在数值上等于吸附层、扩散层中电荷离子所带电荷总和",{"id":90,"libraryId":5,"type":15,"typeLabel":16,"stem":91,"options":92,"answer":31,"analysis":33},878789,"在正常情况下，为保证城市生活给水管网供给用户所需水量，布置管网时，下列哪项正确？( )",[93,95,97,99],{"key":20,"text":94,"correct":22},"必须按压分区供水",{"key":24,"text":96,"correct":22},"供水水质必须符合生活饮用水卫生标准",{"key":28,"text":98,"correct":22},"必须布置成枝状管网",{"key":31,"text":100,"correct":26},"必须保证管网有足够的水压",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":28,"analysis":33},878790,"下列多水源供水方案中，哪项供水方案最可能保障城市用水量和水质安全？( )",[105,107,109,111],{"key":20,"text":106,"correct":22},"从同一个河流不同位置取水的双水厂供水方案",{"key":24,"text":108,"correct":22},"从同一河流同一位置取水的双水厂供水方案",{"key":28,"text":110,"correct":26},"从不同河流(水质差异小)取水的双水厂供水方案",{"key":31,"text":112,"correct":22},"从不同河流(水质差异较大)取水的双水厂供水方案",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":115,"options":116,"answer":20,"analysis":33},878791,"管网漏损率与下列哪项无关？( )",[117,119,121,123],{"key":20,"text":118,"correct":26},"供水规模",{"key":24,"text":120,"correct":22},"供水压力",{"key":28,"text":122,"correct":22},"供水管材",{"key":31,"text":124,"correct":22},"供水管径",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":31,"analysis":33},878792,"在下列哪种情况下，城镇配水管网设计可考虑增大管网漏损率？( )",[129,131,133,135],{"key":20,"text":130,"correct":22},"供水规模较大时",{"key":24,"text":132,"correct":22},"供水压力较低时",{"key":28,"text":134,"correct":22},"管材材质较好时",{"key":31,"text":136,"correct":26},"单位管长供水量较小时",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":28,"analysis":33},878793,"一座虹吸滤池分为多格，下述对其运行工艺特点的叙述中，哪项正确？( )",[141,143,145,147],{"key":20,"text":142,"correct":22},"正常运行时，各格滤池的滤速不同",{"key":24,"text":144,"correct":22},"正常运行时，各格滤池的进水流量不同",{"key":28,"text":146,"correct":26},"正常运行时，各格滤池的水头损失不同",{"key":31,"text":148,"correct":22},"-格冲洗时，其他几格滤池的滤速变化不同",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":151,"answer":28,"analysis":33},878794,[152,154,156,158],{"key":20,"text":153,"correct":22},"Na离子交换器之后，H离子交换器之前",{"key":24,"text":155,"correct":22},"H和Na离子交换器之后",{"key":28,"text":157,"correct":26},"H离子交换器之后，Na离子交换器之前",{"key":31,"text":159,"correct":22},"H和Na离子交换器之前",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":24,"analysis":33},878795,"下列有关输水管设计流量的叙述中，哪项正确？( )",[164,166,168,170],{"key":20,"text":165,"correct":22},"从净水厂至城市管网的清水输水管设计流量等于最高日最大时供水量和输水干管漏损水量之和",{"key":24,"text":167,"correct":26},"从水源至净水厂的原水输水管设计流量等于水处理构筑物设计水量和原水输水管漏损水量之和",{"key":28,"text":169,"correct":22},"从净水厂至城市管网中高位水池的清水输水管设计流量等于向高位水池输水流量和高位水池向管网供水量之和",{"key":31,"text":171,"correct":22},"从水厂滤池至清水池的输水管设计流量等于最高日最大时供水量和水厂自用水量之和",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":24,"analysis":33},878796,"在进行管道经济比较时常用到“年折算费用”的概念，以下关于“年折算费用”的概念论述中，哪项错误？( )",[176,178,180,182],{"key":20,"text":177,"correct":22},"“年折算费用”综合考虑了管道造价和管理费用的因素",{"key":24,"text":179,"correct":26},"“年折算费用”不能用作不同管材之间的经济比较",{"key":28,"text":181,"correct":22},"“年折算费用”最小的管道流速即为经济流速",{"key":31,"text":183,"correct":22},"“年折算费用”的大小与投资偿还期有关",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":31,"analysis":33},878797,"给水供水泵站水泵选择及相关要求中，哪一项是正确的？( )",[188,190,192,194],{"key":20,"text":189,"correct":22},"供水量变化较大且台数较少时，应考虑大、小泵搭配，并各设备用泵。",{"key":24,"text":191,"correct":22},"给水系统最高日最高时供水量时，水泵应处于最高效率",{"key":28,"text":193,"correct":22},"采用自灌充水的大型水泵，启动时间不宜超过5min",{"key":31,"text":195,"correct":26},"供水量和水压变化较大时，可改变水泵特性使水泵在高效区运行",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":20,"analysis":33},878798,"在设计远距离、沿途无出流的压力输水系统时，常对是否采用水泵加压方式做定性分析，下述其优、缺点表述错误的是哪一项？( )",[200,202,204,206],{"key":20,"text":201,"correct":26},"减少了起端输水压力，因而能减少运行能耗",{"key":24,"text":203,"correct":22},"降低了系统工作压力，因而能减少漏损水量",{"key":28,"text":205,"correct":22},"增加了中途增压泵房，因而会增加管理费用",{"key":31,"text":207,"correct":22},"增加了中途增压泵房，因而会增加运行能耗",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":20,"analysis":33},878799,"对于设置于河流宽度不大且有航运要求的河流的河床式取水构筑物，不宜采用下列哪项取水方式？( )",[212,214,216,218],{"key":20,"text":213,"correct":26},"桥墩式取水",{"key":24,"text":215,"correct":22},"自流式取水",{"key":28,"text":217,"correct":22},"虹吸式取水",{"key":31,"text":219,"correct":22},"水泵直接取水",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":24,"analysis":33},878800,"当采用常规处理工艺处理受污染地表水时，为减少氯化消毒副产物三卤甲烷等的产物，不建议采用的是以下哪一项？( )",[224,226,228,230],{"key":20,"text":225,"correct":22},"加强常规处理工艺的措施",{"key":24,"text":227,"correct":26},"先加氯后加氨的氯胺消毒法",{"key":28,"text":229,"correct":22},"氯和氨同时加注的氯胺消毒法",{"key":31,"text":231,"correct":22},"二氧化氯消毒法",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":24,"analysis":33},878801,"在管网进行优化设计时，下列何项因素不影响优化的比较？( )",[236,238,240,242],{"key":20,"text":237,"correct":22},"管网的敷设费用",{"key":24,"text":239,"correct":26},"节点的流量分配",{"key":28,"text":241,"correct":22},"管网中调节水池容积",{"key":31,"text":243,"correct":22},"事故时水量保证率",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":24,"analysis":33},878802,"某小镇地形平坦，给水系统设置水塔，水塔或设在网中，或设在网后，若设在网中或网后的水塔高度、容积和水深均相同，在转输最大转输流量时，对于水厂二级泵站的实际扬程，以下哪种说法正确？( )",[248,250,252,254],{"key":20,"text":249,"correct":22},"网中水塔与网后水塔相同",{"key":24,"text":251,"correct":26},"网中水塔小于网后水塔",{"key":28,"text":253,"correct":22},"网中水塔大于网后水塔",{"key":31,"text":255,"correct":22},"当最大转输时供水流量小于最高日最大时供水量时，总比最大时的实际扬程低",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":28,"analysis":33},878803,"下列有关城镇生活、消防用水合并的管网的布置要求叙述中，哪几项正确？( )",[260,262,264,266],{"key":20,"text":261,"correct":22},"必须布置成环状管网",{"key":24,"text":263,"correct":22},"应布置成枝状管网",{"key":28,"text":265,"correct":26},"消防给水管道直径不应小于100mm",{"key":31,"text":267,"correct":22},"室外消火栓间距不应小于120m",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":270,"answer":31,"analysis":33},878804,[271,273,275,277],{"key":20,"text":272,"correct":22},"大口井",{"key":24,"text":274,"correct":22},"管井",{"key":28,"text":276,"correct":22},"复合井",{"key":31,"text":278,"correct":26},"辐射井",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":28,"analysis":33},878805,"某厂(在非多风地区)选用多个同规格的双侧进风逆流式机械通风冷却塔，其每格进风口高1.5m，由于地形限制，采用长轴不在同一直线的三排平面布置。下列表述错误的是哪项？( )",[283,285,287,289],{"key":20,"text":284,"correct":22},"塔的进风面宜平行于夏季主导风向",{"key":24,"text":286,"correct":22},"不同排冷却塔进风口之间的距离不小于6m",{"key":28,"text":288,"correct":26},"进风口宜设百叶窗式导风装置",{"key":31,"text":290,"correct":22},"冷却塔填料底部至集水池之间宜设挡风隔板",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":31,"analysis":33},878806,"下列关于冷却构筑物特点叙述中，正确的是哪项？( )",[295,297,299,301],{"key":20,"text":296,"correct":22},"冷却循环水的水库和建造的冷却喷水池都属于水面冷却构筑物",{"key":24,"text":298,"correct":22},"自然通风冷却利用自然进入的冷空气带出热量，属于敞开式冷却构筑物",{"key":28,"text":300,"correct":22},"机械通风冷却塔因机械强制抽风鼓风，需要建造一定高度的风筒，属于闭式冷却构筑物",{"key":31,"text":302,"correct":26},"利用江河、湖泊、水库冷却循环热水时，应将热水和冷水水体相互混合，尽快降温",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":31,"analysis":33},878807,"水源情况是一个城市给水系统布置的主要影响因素之一，下列关于这种影响的叙述中，哪项错误？( )",[307,309,311,313],{"key":20,"text":308,"correct":22},"水源种类和水质条件将直接影响水处理工艺流程",{"key":24,"text":310,"correct":22},"水源地平面位置将直接影响输水管渠的工程量",{"key":28,"text":312,"correct":22},"水源地的地形将直接影响取水工程的布置",{"key":31,"text":314,"correct":26},"水源地的高程将直接影响水处理工艺选择",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":24,"analysis":33},878808,"某工厂将设备冷却排水不经处理直接用作工艺用水。该系统为何种给水系统？( )",[319,321,323,325],{"key":20,"text":320,"correct":22},"直流给水系统",{"key":24,"text":322,"correct":26},"复用给水系统",{"key":28,"text":324,"correct":22},"分质给水系统",{"key":31,"text":326,"correct":22},"循环给水系统",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":20,"analysis":33},878809,"对于设有调节水池的配水管网，下列提法中何项是错误的？( )",[331,333,335,337],{"key":20,"text":332,"correct":26},"二级泵房至管网的最大流量为最高日最高时用户用水量",{"key":24,"text":334,"correct":22},"夜间转输时二级泵至管网的流量大于用户用水量",{"key":28,"text":336,"correct":22},"配水管网节点流量与调节水池容积无关",{"key":31,"text":338,"correct":22},"非转输时二级泵房供水范围分界线与调节水池容积有关",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":24,"analysis":33},878810,"在进行枝状网计算时，当控制点合理选定以后，枝状网支线的管径确定方法是下列哪项？( )",[343,345,347,349],{"key":20,"text":344,"correct":22},"按经济流速，由支线的流量确定",{"key":24,"text":346,"correct":26},"根据支线起点与终点的水压标高之差，结合支线的流量计算确定",{"key":28,"text":348,"correct":22},"根据能量方程计算确定",{"key":31,"text":350,"correct":22},"根据连续性方程计算确定",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":28,"analysis":33},878811,"下列有关配水管的描述中，哪项正确？( )",[355,357,359,361],{"key":20,"text":356,"correct":22},"包括输水管以及供水区域内各用户的管道",{"key":24,"text":358,"correct":22},"除管道以外，还包括增压泵站和调节设施",{"key":28,"text":360,"correct":26},"是指将清水配送至供水区域内各用户的管道",{"key":31,"text":362,"correct":22},"由向供水区域内各用户供水的支管构成",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":24,"analysis":33},878812,"在混凝过程中，影响水中憎水胶体颗粒相互聚结的主要因素是下列哪一项？( )",[367,369,371,373],{"key":20,"text":368,"correct":22},"胶体表面水化膜的阻碍作用",{"key":24,"text":370,"correct":26},"胶体表面电荷的排斥作用",{"key":28,"text":372,"correct":22},"胶体表面细菌菌落的阻碍作用",{"key":31,"text":374,"correct":22},"水中溶解杂质的布朗作用",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":24,"analysis":33},878813,"在一定条件下组成城镇生活用水给水系统时，下列何项工程设施可不设置？( )",[379,381,383,385],{"key":20,"text":380,"correct":22},"管网",{"key":24,"text":382,"correct":26},"泵站",{"key":28,"text":384,"correct":22},"取水构筑物",{"key":31,"text":386,"correct":22},"水处理设施",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":28,"analysis":33},878814,"以下关于用水点的服务水头的描述，哪项正确？( )",[391,393,395,397],{"key":20,"text":392,"correct":22},"从供水区域内统一的基准水平面算起，量测该用水点的测压管水柱所达到的高度",{"key":24,"text":394,"correct":22},"从该用水点接管处的管中心算起，量测该用水点的测压管水柱所达到的高度",{"key":28,"text":396,"correct":26},"从该用水点接管处的地面上算起，量测该用水点的测压管水柱所达到的高度",{"key":31,"text":398,"correct":22},"从该用水点接管处的管内顶算起，量测该用水点的测压管水柱所达到的高度",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":28,"analysis":33},878815,"设计山区浅水河流取水构筑物时，下列观点中错误的是何项？( )",[403,405,407,409],{"key":20,"text":404,"correct":22},"推移质不多的山区河流可采用低坝取水",{"key":24,"text":406,"correct":22},"固定式低坝取水构筑物主要有拦河低坝、冲砂闸、进水闸组成",{"key":28,"text":408,"correct":26},"大颗粒推移质不多的山区河流宜采用底栏栅取水",{"key":31,"text":410,"correct":22},"底栏栅取水构筑物应避开山洪影响较大的区域",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":31,"analysis":33},878816,"为防止絮凝体破碎，从絮凝池通过穿孔花墙进入沉淀池的流速一般不大于絮凝池末端流速，该流速大小与下列何项因素有关？( )",[415,417,419,421],{"key":20,"text":416,"correct":22},"穿孔花墙过水孔淹没高度",{"key":24,"text":418,"correct":22},"穿孔花墙过水孔开孔形状",{"key":28,"text":420,"correct":22},"穿孔花墙过水孔开孔个数",{"key":31,"text":422,"correct":26},"穿孔花墙过水孔面积大小",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":20,"analysis":33},878817,"某循环冷却水系统在生产工艺改造后，其循环冷却水量减小10%，若系统浓缩倍数和冷却系统进出水温度不变，则该系统的补充水量应按下列哪项调整？( )",[427,429,431,433],{"key":20,"text":428,"correct":26},"减小10%",{"key":24,"text":430,"correct":22},"减小5%",{"key":28,"text":432,"correct":22},"不变",{"key":31,"text":434,"correct":22},"无法确定",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":24,"analysis":33},878818,"在环状管网平差时，当相邻二环的闭合差方向一致时，其公共管段的校正流量应为下列何项？( )",[439,441,443,445],{"key":20,"text":440,"correct":22},"相邻二环校正流量绝对值之和",{"key":24,"text":442,"correct":26},"相邻二环校正流量绝对值之差",{"key":28,"text":444,"correct":22},"相邻二环校正流量绝对值之和的一半",{"key":31,"text":446,"correct":22},"相邻二环校正流量绝对值之差的一半",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":28,"analysis":33},878819,"在湖泊、水库边修建取水构筑物时，下列说法中错误的是哪项？( )",[451,453,455,457],{"key":20,"text":452,"correct":22},"浅水湖的夏季主风向的向风面的凹岸处水质较差",{"key":24,"text":454,"correct":22},"水深较大的水库内设置分层取水可取得水质较好的水",{"key":28,"text":456,"correct":26},"湖泊中浮游生物湖中心比近岸处少，深水处比浅水处多",{"key":31,"text":458,"correct":22},"河床式水库具有河流水文特征，泥砂运动接近天然河流",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":20,"analysis":33},878820,"根据“理想沉淀池”基本假定条件，分析平流式沉淀池的实际沉淀过程得出的如下判断中，不正确的是哪一项？( )",[463,465,467,469],{"key":20,"text":464,"correct":26},"随着实际沉淀池深度增加，颗粒不易沉到池底，总去除率低于“理想沉淀池”去除率",{"key":24,"text":466,"correct":22},"在水平方向的流速不相等，出现短流，部分颗粒带出池外，总去除率低于“理想沉淀池”去除率",{"key":28,"text":468,"correct":22},"由于出口水流扰动，部分颗粒带出池外，总去除率低于“理想沉淀池”去除率",{"key":31,"text":470,"correct":22},"沉到池底的颗粒因扰动会返回水中随水流带出池外，总去除率低于“理想沉淀池”去除率",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":24,"analysis":33},878821,"下列哪个城镇选用的生活用水定额不在现行规范推荐范围内？( )",[475,477,479,481],{"key":20,"text":476,"correct":22},"位于青海省的某城镇，规划人口20万人，最高日居民生活用水定额取110L\u002F(人·d)",{"key":24,"text":478,"correct":26},"位于广东省的某城镇，规划人口30万人，最高日居民生活用水定额取130L\u002F(人·d)",{"key":28,"text":480,"correct":22},"位于吉林省的某城镇，规划人口40万人，最高日综合生活用水定额取230L\u002F(人·d)",{"key":31,"text":482,"correct":22},"位于江苏省的某城镇，规划人口40万人，最高日综合生活用水定额取300L\u002F(人·d)",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":31,"analysis":33},878822,"远距离重力输水管从A点经B点向C点输水且无集中出流，现需在B点设一开敞减压水池，则下列哪项表述不准确？( )",[487,489,491,493],{"key":20,"text":488,"correct":22},"B点设开敞水池后可降低爆管概率",{"key":24,"text":490,"correct":22},"B点池底的自由水压即为水池的水深",{"key":28,"text":492,"correct":22},"A点水压标高大于其下游管段上任意一点的水压标高",{"key":31,"text":494,"correct":26},"A-B管段管径不得小于B-C管段管径",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":20,"analysis":33},878823,"判断循环冷却水系统中循环水水质稳定性的指标是下列何项？( )",[499,501,503,505],{"key":20,"text":500,"correct":26},"饱和指数",{"key":24,"text":502,"correct":22},"污垢热",{"key":28,"text":504,"correct":22},"缓蚀率",{"key":31,"text":506,"correct":22},"浊度",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":28,"analysis":33},878824,"以地表水为水源的城镇供水系统流程为：水源→一泵房→水厂处理构筑物→清水池→二泵房→管网，指出上述流程中输配水管道设计流量最小的为下列哪项？( )",[511,513,515,517],{"key":20,"text":512,"correct":22},"一泵房→水厂处理构筑物输配水管道设计流量",{"key":24,"text":514,"correct":22},"水厂处理构筑物→清水池输配水管道设计流量",{"key":28,"text":516,"correct":26},"清水池→二泵房输配水管道设计流量",{"key":31,"text":518,"correct":22},"二泵房→管网输配水管道设计流量",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":24,"analysis":33},878825,"对于进、出水水位固定的两条并行敷设、直径和材质完全相同的输水管线，影响其事故水量保证率的因素除了连通管的根数外，主要还与下列何项因素有关？( )",[523,525,527,529],{"key":20,"text":524,"correct":22},"输水管线长度",{"key":24,"text":526,"correct":26},"连通管设置位置",{"key":28,"text":528,"correct":22},"输水管直径",{"key":31,"text":530,"correct":22},"输水管线水力坡降",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":20,"analysis":33},878826,"下列关于原水输水管道设计的要求中，错误的是哪一项？( )",[535,537,539,541],{"key":20,"text":536,"correct":26},"必须采用双管或多管输水",{"key":24,"text":538,"correct":22},"尽量沿现有或规划道路敷设",{"key":28,"text":540,"correct":22},"埋设在测压管水头线以下",{"key":31,"text":542,"correct":22},"长距离输水应检测流量",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":28,"analysis":33},878827,"供水管网进行平差的目的是下列哪项？( )",[547,549,551,553],{"key":20,"text":548,"correct":22},"保证管网节点流量的平衡",{"key":24,"text":550,"correct":22},"保证管网中各管段的水头损失相同",{"key":28,"text":552,"correct":26},"为了确定管段直径，水头损失以及水泵扬程等",{"key":31,"text":554,"correct":22},"消除管网中管段高程的闭合差",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":28,"analysis":33},878828,"下列有关城市给水管网的表述中，哪项不正确？( )",[559,561,563,565],{"key":20,"text":560,"correct":22},"当输水干管采用两条时，也应进行事故时管网供水量的核算",{"key":24,"text":562,"correct":22},"管网布置成环状网时，干管间距可采用500～800m",{"key":28,"text":564,"correct":26},"与枝状网相比，管网布置成环状网时，供水安全性提高主要是其抗水锤能力强",{"key":31,"text":566,"correct":22},"对同一城市，与枝状网相比，管网布置成环状网时投资要高",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":28,"analysis":33},878829,"当给水管网中无水量调节设施时，水厂二级泵房供水泵宜按下列哪项选型？( )",[571,573,575,577],{"key":20,"text":572,"correct":22},"根据水泵效率曲线选择最高效率点",{"key":24,"text":574,"correct":22},"选择最高效率点一侧效率曲线上升区段间的点，并位于高效区",{"key":28,"text":576,"correct":26},"选择最高效率点一侧效率曲线下降区段间的点，并位于高效区",{"key":31,"text":578,"correct":22},"处于高效区即可",{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":31,"analysis":33},878830,"下述冷却水量、冷幅宽和冷幅高都相同的单座逆流式冷却塔与横流式冷却塔的差别中，不正确的是何项？( )",[583,585,587,589],{"key":20,"text":584,"correct":22},"逆流式冷却塔的风阻大",{"key":24,"text":586,"correct":22},"逆流式冷却塔热交换效率高",{"key":28,"text":588,"correct":22},"逆流式冷却塔填料容积少",{"key":31,"text":590,"correct":26},"逆流式冷却塔风机排气回流较大",{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":20,"analysis":33},878831,"埋地给水管与下列哪项管道的允许最小水平净距值最小？( )",[595,597,599,601],{"key":20,"text":596,"correct":26},"低压燃气管",{"key":24,"text":598,"correct":22},"雨水管",{"key":28,"text":600,"correct":22},"污水管",{"key":31,"text":602,"correct":22},"热水管",{"id":604,"libraryId":5,"type":15,"typeLabel":16,"stem":605,"options":606,"answer":24,"analysis":33},878832,"在管径选择中，进行经济管径计算的目的是下列何项？( )",[607,609,611,613],{"key":20,"text":608,"correct":22},"使一次投资的管道造价最低",{"key":24,"text":610,"correct":26},"使年折算费用最低",{"key":28,"text":612,"correct":22},"使投资偿还期内电费最低",{"key":31,"text":614,"correct":22},"使管道造价与年管理费用之和最低",[616,619,622,625,628,631],{"id":15,"name":617,"category":7,"favorite":618},"领导干部任职前廉政法规知识测试题",92,{"id":620,"name":621,"category":7,"favorite":15},595,"建筑结构与设备",{"id":623,"name":624,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":626,"name":627,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":629,"name":630,"category":7,"favorite":8},534,"BIM工程师",{"id":632,"name":630,"category":7,"favorite":8},535]