[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-568-21":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":617},{"id":5,"name":6,"category":7,"favorite":8},568,"专业知识（给排水）","建筑工程",0,21,50,1213,[13,35,48,61,74,87,99,112,124,137,149,161,174,186,197,209,221,233,245,257,269,276,288,300,313,325,337,345,357,369,381,393,405,417,429,441,453,465,477,489,501,513,521,533,546,557,569,581,593,605],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},879636,2,"多选题","以下有关建筑屋面雨水溢流设施的叙述中，哪几项是错误的？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","屋面雨水排水工程应设置溢流设施",false,{"key":24,"text":25,"correct":26},"B","当屋面各汇水面积内有两根或两根以上雨水立管时，可不设雨水溢流设施",true,{"key":28,"text":29,"correct":26},"C","雨水溢流设施主要是排除雨水管道堵塞时的设计雨水量",{"key":31,"text":32,"correct":26},"D","当屋面雨水管系按设计降雨重现期P对应的降雨强度为依据正确设计时，则P年内该雨水排水系统不会产生溢流现象","BCD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},879637,"下列关于室内给水管道设置要求的叙述中，哪几项不正确？( )",[39,41,43,45],{"key":20,"text":40,"correct":26},"塑料给水管道均应采取伸缩补偿措施",{"key":24,"text":42,"correct":22},"给水管道不得直接敷设在楼板结构层内",{"key":28,"text":44,"correct":22},"办公室墙角明设的给水立管穿楼板时应采取防水措施",{"key":31,"text":46,"correct":26},"室内、外埋地给水管与污水管交叉时的敷设要求相同","AD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},879638,"以下哪些是住宅建筑给水系统的必要组成部分？( )",[52,54,56,58],{"key":20,"text":53,"correct":26},"水表",{"key":24,"text":55,"correct":26},"给水管道",{"key":28,"text":57,"correct":22},"紫外线消毒器",{"key":31,"text":59,"correct":26},"水嘴","ABD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},879639,"某13层教学楼地下室层高2.4m，1～13层公共卫生间均采用异层排水方式，排水立管的排出管从地下室排出，公共厕所采用伸顶通气管排水系统。下列该教学大楼的公共卫生间排水系统设计中，哪几项不正确？( )",[65,67,69,71],{"key":20,"text":66,"correct":26},"首层卫生间的排水支管接至排水立管的排出管上，其连接点距排水立管底部下游水平距离为1.5m",{"key":24,"text":68,"correct":22},"首层卫生间的排水支管可排入排水立管",{"key":28,"text":70,"correct":26},"首层卫生间的排水支管单独排至室外检查井",{"key":31,"text":72,"correct":22},"首层卫生间的排水管单独排出是为了提高排水能力","AC",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":86,"analysis":34},879640,"下列高层建筑室内临时高压消火栓给水系统的消防主泵房启、停控制方式中，哪几项是不正确的？( )",[78,80,82,84],{"key":20,"text":79,"correct":22},"每个消火栓处应能直接启动消防主泵",{"key":24,"text":81,"correct":26},"消防控制中心应能手动启、停消防主泵",{"key":28,"text":83,"correct":22},"消防水泵房应能强制启、停消防主泵",{"key":31,"text":85,"correct":26},"消防水池最低水位应能自动停止消防水泵","BD",{"id":88,"libraryId":5,"type":15,"typeLabel":16,"stem":89,"options":90,"answer":33,"analysis":34},879641,"下列某液化气罐装间水喷雾灭火系统设计方案，哪几项正确？( )",[91,93,95,97],{"key":20,"text":92,"correct":22},"水喷雾的工作压力不应小于0.35MPa",{"key":24,"text":94,"correct":26},"系统保护面积按罐装间建筑使用面积确定",{"key":28,"text":96,"correct":26},"系统管道采用均衡布置时可减少系统设计流量",{"key":31,"text":98,"correct":26},"因保护面积较大，设置多台雨淋阀，并利用雨淋阀控制同时喷雾的水喷雾喷头数量",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":111,"analysis":34},879642,"以下有关热水供应系统热源选择的叙述中，那几项不符合要求？( )",[103,105,107,109],{"key":20,"text":104,"correct":26},"选择太阳能为热源的全日制集中热水供应系统时，应设置辅助加热装置",{"key":24,"text":106,"correct":26},"因电能制备热水的成本较高，故不能作为集中热水供应系统的热源",{"key":28,"text":108,"correct":26},"若地热水的水量、水压满足供水要求，可直接用于热水供应",{"key":31,"text":110,"correct":22},"利用烟气为热源时，加热设备应采取防腐措施","ABC",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":60,"analysis":34},879643,"下列排水管间接排水口的最小空气间隙中，哪几项是正确的？( )",[116,118,120,122],{"key":20,"text":117,"correct":26},"热水器排水管管径25mm，最小空气间隙为50mm",{"key":24,"text":119,"correct":26},"热水器排水管管径50mm，最小空气间隙为100mm",{"key":28,"text":121,"correct":22},"饮料用水贮水箱灌水管管径50mm，最小空气间隙为125mm",{"key":31,"text":123,"correct":26},"生活饮用水贮水箱泄水管管径80mm，最小空气间隙为150mm",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":136,"analysis":34},879644,"下列关于屋面雨水排水系统设计的叙述中，哪几项不正确？( )",[128,130,132,134],{"key":20,"text":129,"correct":26},"满管压力流管系中最大负压出现在雨水斗与悬吊管连接处",{"key":24,"text":131,"correct":22},"满管压力流管系中最大压力源自管系进口与出口的高差",{"key":28,"text":133,"correct":26},"为保证满管压力流的形成应增加管系的水头损失",{"key":31,"text":135,"correct":26},"满管压力流管系的管路等效长度是指最不利计算管路的设计管长","ACD",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":60,"analysis":34},879645,"下述哪几种灭火系统的灭火机理属于物理灭火过程？( )",[141,143,145,147],{"key":20,"text":142,"correct":26},"二氧化碳灭火系统",{"key":24,"text":144,"correct":26},"消火栓灭火系统",{"key":28,"text":146,"correct":22},"七氟丙烷灭火系统",{"key":31,"text":148,"correct":26},"固定消防水炮灭火系统",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":86,"analysis":34},879646,"拟将收集的屋面雨水用于绿化、冲厕，采用哪几项处理工艺相对适宜？( )",[153,155,157,159],{"key":20,"text":154,"correct":22},"采用曝气生物处理",{"key":24,"text":156,"correct":26},"采用沉淀、过滤处理",{"key":28,"text":158,"correct":22},"采用反渗透膜处理",{"key":31,"text":160,"correct":26},"采用自然沉淀处理",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":173,"analysis":34},879647,"下列关于集中生活热水供应系统热源的选择，哪几项不正确？( )",[165,167,169,171],{"key":20,"text":166,"correct":22},"有工业余热、废热时，宜首先利用",{"key":24,"text":168,"correct":26},"电能是高品质能源，不应用于加热生活热水",{"key":28,"text":170,"correct":26},"在太阳能丰富地区采用太阳能作为热源时，可不再设置其他热源",{"key":31,"text":172,"correct":22},"冷却水升温后如果满足《生活饮用水卫生标准》GB5749-2006，可用作生活热水","BC",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":173,"analysis":34},879648,"下列关于气体灭火系统设计的叙述中，哪几项正确？( )",[178,180,182,184],{"key":20,"text":179,"correct":22},"灭火系统的灭火剂储存量，应为最大防护区的灭火设计用量",{"key":24,"text":181,"correct":26},"设计管网上不应采用四通管件进行分流",{"key":28,"text":183,"correct":26},"灭火系统的设计温度，应采用20℃",{"key":31,"text":185,"correct":22},"扑灭气体类火灾的防护区，必须采用惰化设计浓度",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":188,"answer":86,"analysis":34},879649,[189,191,193,195],{"key":20,"text":190,"correct":22},"管段1-A的设计秒流量为管段A-2、A-3的设计秒流量之和",{"key":24,"text":192,"correct":26},"流入A点流量等于流离A点流量",{"key":28,"text":194,"correct":22},"A点上游各管段的管内压力必不小于下游管段的管内压力",{"key":31,"text":196,"correct":26},"A点上游干管段的直径必不小于下游管段的管径",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":60,"analysis":34},879650,"下列关于医院污水处理设计，哪几项正确？( )",[201,203,205,207],{"key":20,"text":202,"correct":26},"化粪池作为医院污水消毒前的预处理时其容积大于用于一般的生活污水处理的化粪池",{"key":24,"text":204,"correct":26},"传染病房污水应单独消毒后再与普通病房污水合并进行处理",{"key":28,"text":206,"correct":22},"医院污水排入城市下水道时，宜采用一级处理",{"key":31,"text":208,"correct":26},"医院污水消毒处理宜采用氯消毒法",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":73,"analysis":34},879651,"消火栓系统竖向分区供水的条件与下列哪几项有关？( )",[213,215,217,219],{"key":20,"text":214,"correct":26},"系统工作压力大于2.4MPa时",{"key":24,"text":216,"correct":22},"消火栓栓口动压大于0.7MPa时",{"key":28,"text":218,"correct":26},"消火栓栓口静压大于1.0MPa时",{"key":31,"text":220,"correct":22},"消火栓栓口充实水柱大于13m时",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":111,"analysis":34},879652,"下列关于雨水利用系统降雨设计重现期取值的叙述中，哪几项正确？( )",[225,227,229,231],{"key":20,"text":226,"correct":26},"雨水利用设施集水管渠的设计重现期，不应小于该类设施的雨水利用设计重现期",{"key":24,"text":228,"correct":26},"雨水外排管渠的设计重现期，应大于雨水利用设施的设计重现期",{"key":28,"text":230,"correct":26},"调蓄设施的设计重现期宜取2年",{"key":31,"text":232,"correct":22},"雨水利用系统的设计重现期按10年确定",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":136,"analysis":34},879653,"下列有关建筑消防系统灭火设施选择的说法中，哪几项错误？( )",[237,239,241,243],{"key":20,"text":238,"correct":26},"同一建筑物内配置统一规格、型号的灭火器",{"key":24,"text":240,"correct":22},"同一建筑物内应采用统一规格的消火栓及其水枪和水带",{"key":28,"text":242,"correct":26},"设有湿式喷淋系统的同一建筑物内应采用统一规格、型号的闭式喷头",{"key":31,"text":244,"correct":26},"当需要设置气体灭火系统时，应采用统一规格、型号的预制式灭火装置",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":47,"analysis":34},879654,"下列关于小区及建筑生活给水系统的说法，哪些是正确的？( )",[249,251,253,255],{"key":20,"text":250,"correct":26},"小区室外给水系统用水量应满足小区内部全部用水的要求",{"key":24,"text":252,"correct":22},"采用二次加压供水时，应设置生活用水调节设施，如生活用水低位贮水池",{"key":28,"text":254,"correct":22},"市政水压在晚上高峰用水不满足设计水压的要求时，应设置加压设备供水",{"key":31,"text":256,"correct":26},"建筑高度不超过100m的高层建筑宜采用垂直分区并联供水系统",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":73,"analysis":34},879655,"下列关于管道直饮水系统的设置要求中，哪几项错误？( )",[261,263,265,267],{"key":20,"text":262,"correct":26},"直饮水净化处理是在保留有益健康的物质前提下，去除有害物质",{"key":24,"text":264,"correct":22},"直饮水净化处理应去除有害物质，保障水质卫生安全",{"key":28,"text":266,"correct":26},"管道直饮水的循环系统可采用自然循环或机械循环",{"key":31,"text":268,"correct":22},"管道直饮水系统宜采用变频调速泵供水",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":271,"answer":86,"analysis":34},879656,[272,273,274,275],{"key":20,"text":34,"correct":22},{"key":24,"text":34,"correct":26},{"key":28,"text":34,"correct":22},{"key":31,"text":34,"correct":26},{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":136,"analysis":34},879657,"现行《建筑给水排水设计规范》办公楼热水用水定额为每天每班5～10L(60℃)，下列关于该热水用水定额的叙述中，哪几项正确？( )",[280,282,284,286],{"key":20,"text":281,"correct":26},"该定额范围内任何一个值都是最高日的用水定额",{"key":24,"text":283,"correct":22},"5L是平均日的用水定额",{"key":28,"text":285,"correct":26},"缺水地区一般选用较低的值",{"key":31,"text":287,"correct":26},"该定额水量主要用于洗手",{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":136,"analysis":34},879658,"下列关于开式集中热水供应系统的设置中，哪几项正确？( )",[292,294,296,298],{"key":20,"text":293,"correct":26},"系统中不需设置膨胀罐",{"key":24,"text":295,"correct":22},"半容积式热交换罐上可不设安全阀",{"key":28,"text":297,"correct":26},"下行上给式配水系统可不设排气装置",{"key":31,"text":299,"correct":26},"管网系统应设热水循环管道",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":312,"analysis":34},879659,"下列叙述哪几项是不正确的？( )",[304,306,308,310],{"key":20,"text":305,"correct":26},"建筑排水横管起端的清扫口与其端部垂直墙面间的距离最少不应小于0.4m",{"key":24,"text":307,"correct":26},"建筑排水系统每根排出管均宜与室外接户管管顶平接",{"key":28,"text":309,"correct":22},"清扫口可用其相同作用的其他配件替代",{"key":31,"text":311,"correct":22},"当排水立管连接DN100的排出管，其底部至室外检查井的距离大于15m时，应在排出管上设置清扫口","AB",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":73,"analysis":34},879660,"以下对于水喷雾系统的叙述，哪几项错误？( )",[317,319,321,323],{"key":20,"text":318,"correct":26},"水喷雾与高压细水雾的灭火机理相同，喷头所需工作压力也基本相同",{"key":24,"text":320,"correct":22},"水喷雾灭火系统可用于扑救固定物质火灾外，还可适用于扑救丙类液体火灾、电气火灾等不宜用水灭火的场所",{"key":28,"text":322,"correct":26},"水喷雾系统属于闭式系统",{"key":31,"text":324,"correct":22},"水喷雾系统的供水控制阀，可采用雨淋报警阀、电动控制阀或气动控制阀等。但响应时间不大于120s的系统，应采用雨淋报警阀",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":47,"analysis":34},879661,"下列关于建筑生活排水系统通气管的设计，哪几项正确？( )",[329,331,333,335],{"key":20,"text":330,"correct":26},"设有器具通气管时应设环形通气管",{"key":24,"text":332,"correct":22},"通气立管管径应与排水立管管径相同",{"key":28,"text":334,"correct":22},"特殊情况下，屋面专用雨水排水立管可以作为辅助通气管",{"key":31,"text":336,"correct":26},"连接单根排水立管的结合通气管管径不宜小于与其连接的通气立管管径",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":339,"answer":33,"analysis":34},879662,[340,342,343,344],{"key":20,"text":341,"correct":22},"该给水系统设可调式减压阀分区不妥，应设比例式减压阀",{"key":24,"text":34,"correct":26},{"key":28,"text":34,"correct":26},{"key":31,"text":34,"correct":26},{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":86,"analysis":34},879663,"下列关于饮水制备方法和水质要求的叙述中，哪几项是正确的？( )",[349,351,353,355],{"key":20,"text":350,"correct":22},"饮用温水是把自来水加热至接近人体温度的饮水",{"key":24,"text":352,"correct":26},"管道直饮水水质应符合《饮用净水水质标准》",{"key":28,"text":354,"correct":22},"冷饮水水质应符合《生活饮用水卫生标准》",{"key":31,"text":356,"correct":26},"集中制各并用管道输送的开水系统，要求用水加热器加热且其出水温度不小于105℃",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":312,"analysis":34},879664,"某15层宾馆6～15层设有240间客房(共390床，每间客房设卫生间，卫生间设带水箱坐便器以及洗脸盆和浴盆)。其6～15层的生活给水系统拟采用如下增压供水方案：方案一：市政自来水→低位生活水箱→变频供水设备→高区生活给水系统；方案二：市政自来水→低位生活水箱→气压供水设备→高区生活给水系统。下列关于上述两方案比选的说法中，哪几项正确？( )",[361,363,365,367],{"key":20,"text":362,"correct":26},"方案一与方案二系统，配水管网设计流量相同",{"key":24,"text":364,"correct":26},"方案一的增压水泵设计流量大于方案二",{"key":28,"text":366,"correct":22},"方案一的增压水泵设计流量小于方案二",{"key":31,"text":368,"correct":22},"方案一与方案二的增压水泵设计流量相同",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":111,"analysis":34},879665,"下列哪些建筑用房的地面排水应采用间接排水？( )",[373,375,377,379],{"key":20,"text":374,"correct":26},"储存瓶装饮料的冷藏库房的地面排水",{"key":24,"text":376,"correct":26},"储存罐装食品的冷藏库房的地面排水",{"key":28,"text":378,"correct":26},"医院无菌手术室的地面排水",{"key":31,"text":380,"correct":22},"生活饮用水水箱间的地面排水",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":312,"analysis":34},879666,"以下有关生活给水管网水力计算的叙述中，哪几项是错误的？( )",[385,387,389,391],{"key":20,"text":386,"correct":26},"住宅人户管管径应按计算确定，但公称直径不得小于25mm",{"key":24,"text":388,"correct":26},"生活给水管道当其设计流量相同时，可采用同-i值(单位长度水头损失)计算管道沿程水头损失",{"key":28,"text":390,"correct":22},"计算给水管道上比例式减压阀的水头损失时，阀后动水压宜按阀后静水压力的80%～90%采用",{"key":31,"text":392,"correct":22},"生活给水管道配水管的局部水头损失，宜按管道的连接方式，采用管(配)件当量长度法计算",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":173,"analysis":34},879667,"生活饮用水池的防污染措施，以下哪几项做法可行且可靠？( )",[397,399,401,403],{"key":20,"text":398,"correct":22},"由水池顶部进水",{"key":24,"text":400,"correct":26},"水池采用独立结构形式",{"key":28,"text":402,"correct":26},"采用密闭人孔",{"key":31,"text":404,"correct":22},"水泵吸水管上安装过滤器",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":111,"analysis":34},879668,"某七氟丙烷管网灭火系统下列设计中，哪几项错误？( )",[409,411,413,415],{"key":20,"text":410,"correct":26},"设置自动控制和手动控制两种启动方式",{"key":24,"text":412,"correct":26},"在防护区入口处设置手动与自动控制的转换开关",{"key":28,"text":414,"correct":26},"管道在进入各防护区处，设置选择阀",{"key":31,"text":416,"correct":22},"各喷头上标识有型号和规格",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":136,"analysis":34},879669,"下列哪几项与高层建筑热水供应系统的设计要求不完全符合？( )",[421,423,425,427],{"key":20,"text":422,"correct":26},"热水供应系统竖向分区供水方式，可解决循环水泵扬程过大的问题",{"key":24,"text":424,"correct":22},"热水供应系统采用减压阀分区时，减压阀的设置位置不应影响各分区系统热水的循环",{"key":28,"text":426,"correct":26},"热水供应系统竖向分区范围超过5层时，为使各配水点随时得到设计要求的水温，应采用干、立管循环方式",{"key":31,"text":428,"correct":26},"热水供应系统与冷水系统竖向分区必须一致，否则不能保证冷水和热水回水压力平衡",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":86,"analysis":34},879670,"某小区从城市给水环网东西两侧干管分别连接引入管，小区内室外给水干管与市政管网连接成环，引入管上水表前供水压力为0.25MPa(从地面算起)，若不计水表及小区内管网水头损失，则下述小区住宅供水方案中哪几项是正确合理的？( )",[433,435,437,439],{"key":20,"text":434,"correct":22},"利用市政供水压力直接供至5层，6层及6层以上采用变频加压供水",{"key":24,"text":436,"correct":26},"利用市政供水压力直接供至4层，5层及5层以上采用变频加压供水",{"key":28,"text":438,"correct":22},"利用市政供水压力直接供至3层，4层及4层以上采用变频加压供水",{"key":31,"text":440,"correct":26},"利用市政供水压力直接供至4层，5层及5层以上采用水泵加高位水箱供水",{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":47,"analysis":34},879671,"以下关于建筑给水的几种基本给水系统的论述哪几项是正确的？( )",[445,447,449,451],{"key":20,"text":446,"correct":26},"生活给水系统、生产给水系统、消防给水系统",{"key":24,"text":448,"correct":22},"生活给水系统、生产给水系统、消防给水系统、组合给水系统",{"key":28,"text":450,"correct":22},"生活给水系统、生产给水系统、组合给水系统",{"key":31,"text":452,"correct":26},"生活给水系统、生产给水系统、消防给水系统。而生活、生产、消防又可组成组合给水系统",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":33,"analysis":34},879672,"下列有关建筑给水系统分类及其水质要求的说法中，哪几项错误？( )",[457,459,461,463],{"key":20,"text":458,"correct":22},"供绿化和冲洗道路的中水给水系统属于生活给水系统",{"key":24,"text":460,"correct":26},"生产给水系统对水质的要求高于生活杂用水，但低于生活饮用水",{"key":28,"text":462,"correct":26},"车间内卫生间、浴室的给水系统属于生产给水系统",{"key":31,"text":464,"correct":26},"建筑给水系统中管道直饮水水质标准要求最高",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":60,"analysis":34},879673,"下述消火栓给水系统消防水泵房的设计要求中，哪几项不符合《建筑设计防火规范》的要求？( )",[469,471,473,475],{"key":20,"text":470,"correct":26},"附设在民用建筑中的消防水泵房应采用防火墙与其他部位隔开",{"key":24,"text":472,"correct":26},"附设在民用建筑中的消防水泵房不应贴邻人员密集场所",{"key":28,"text":474,"correct":22},"消防水泵房内设置水泵的房间，应设排水设施",{"key":31,"text":476,"correct":26},"消防水泵房应采用乙级防火门",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":111,"analysis":34},879674,"下列建筑生活排水系统清扫口与检查口设计的叙述中，哪几项错误？( )",[481,483,485,487],{"key":20,"text":482,"correct":26},"偏转角不大于45°的排水横管，可不设清扫口或检查口",{"key":24,"text":484,"correct":26},"塑料排水立管上宜每隔六层设置排水检查口",{"key":28,"text":486,"correct":26},"排水管道上的清扫口，应采用与管道同材质的清扫口",{"key":31,"text":488,"correct":22},"排水管起端可采用堵头代替清扫口",{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":136,"analysis":34},879675,"以下有关热水供水系统管网水力计算要求的叙述中，哪几项是不正确的？( )",[493,495,497,499],{"key":20,"text":494,"correct":26},"热水循环供应系统的热水回水管管径，应按管路剩余回流量经水力计算确定",{"key":24,"text":496,"correct":22},"定时循环热水供应系统在供应热水时，不考虑热水循环",{"key":28,"text":498,"correct":26},"定时循环热水供应系统在供应热水时，应考虑热水循环",{"key":31,"text":500,"correct":26},"居住小区设有集中热水供应系统的建筑，其热水引入管管径按该建筑物相应热水供应系统的总干管设计流量确定",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":136,"analysis":34},879676,"居住小区生活排水系统的排水定额为其相应给水定额的85%～95%，在确定排水定额时，该百分数的取值应遵循下列哪几项原则？( )",[505,507,509,511],{"key":20,"text":506,"correct":26},"地下水位高时取高值",{"key":24,"text":508,"correct":22},"地下水位低时取高值",{"key":28,"text":510,"correct":26},"大城市的小区取高值",{"key":31,"text":512,"correct":26},"埋地管采用排水塑料管时取高值",{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":86,"analysis":34},879677,"某住宅居住人数300人，每户设有大便器、洗脸盆、洗衣机、沐浴用电热水器。则下列哪几项的q值在该住宅最高日生活用水量的合理取值范围内？( )",[517,518,519,520],{"key":20,"text":34,"correct":22},{"key":24,"text":34,"correct":26},{"key":28,"text":34,"correct":22},{"key":31,"text":34,"correct":26},{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":86,"analysis":34},879678,"以下关于生活排水立管中水气流动规律的叙述中，哪几项正确？( )",[525,527,529,531],{"key":20,"text":526,"correct":22},"排水立管水膜流时的通水能力不能作为排水立管最大排水流量的依据",{"key":24,"text":528,"correct":26},"终限长度是从排水横支管水流入口处至终限流速形成处的高度",{"key":28,"text":530,"correct":22},"在水膜流阶段，立管内的充水率在1\u002F4～2\u002F3之间",{"key":31,"text":532,"correct":26},"当水膜的下降速度和水膜厚度不再变化时，水流在立管中匀速下降",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":545,"analysis":34},879679,"下列有关热泵热水供应系统热源的叙述中，哪几项不符合要求？( )",[537,539,541,543],{"key":20,"text":538,"correct":22},"环境低温热能为热泵热水供应系统的热源",{"key":24,"text":540,"correct":22},"最冷月平均气温不低于10℃的地区，宜采用空气做热源",{"key":28,"text":542,"correct":26},"空气源热泵热水供应系统均不需设辅助热源",{"key":31,"text":544,"correct":26},"水温、水质符合要求的地热水，均可直接用作水源热泵的热源","CD",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":548,"answer":136,"analysis":34},879680,[549,551,553,555],{"key":20,"text":550,"correct":26},"两格水池大小相差太大",{"key":24,"text":552,"correct":22},"左池溢、泄水管可取消，共用右池溢、泄水管",{"key":28,"text":554,"correct":26},"进出水管同侧",{"key":31,"text":556,"correct":26},"水池后侧距墙500mm，距离太小",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":47,"analysis":34},879681,"下列哪几项符合热水供应系统的设计要求？( )",[561,563,565,567],{"key":20,"text":562,"correct":26},"集中热水供应系统应设热水回水管道，并保证干管和立管中的热水循环",{"key":24,"text":564,"correct":22},"公共浴室成组淋浴器各段配水管的管径应按设计流量确定",{"key":28,"text":566,"correct":22},"给水管道的水压变化较大，且用水点要求水压稳定时，不应采用减压稳压阀热水供应系统，只能采用开式热水供应系统",{"key":31,"text":568,"correct":26},"单管热水供应系统应有自动调节冷热水水量比的技术措施，以保证热水水温的稳定",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":86,"analysis":34},879682,"某座商店建筑，总建筑面积3900㎡，地上两层，建筑面积2900㎡，地下一层，建筑面积1000㎡，建筑高度8m，以下关于消防灭火设施的设置，哪几项是错误的？( )",[573,575,577,579],{"key":20,"text":574,"correct":22},"该建筑应设置自动喷水灭火系统、室内外消火栓系统，并配置灭火器",{"key":24,"text":576,"correct":26},"自动喷水灭火系统的设计参数按中危险工级取值",{"key":28,"text":578,"correct":22},"按中危险级场所配置灭火器",{"key":31,"text":580,"correct":26},"室内消火栓系统设计流量为15L\u002Fs",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":73,"analysis":34},879683,"对60℃以上(闪点低于28℃)的白酒库，不宜选用水喷雾灭火系统，主要原因是灭火时，有些不能产生综合效应，指出是下列哪几项？( )",[585,587,589,591],{"key":20,"text":586,"correct":26},"表面冷却作用",{"key":24,"text":588,"correct":22},"窒息作用",{"key":28,"text":590,"correct":26},"乳化作用",{"key":31,"text":592,"correct":22},"稀释作用",{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":86,"analysis":34},879684,"下列有关建筑排水系统通气管、清扫口的管径选择，哪几项是正确的？( )",[597,599,601,603],{"key":20,"text":598,"correct":22},"排水管道上设置的清扫口，其尺寸应与排水管道同径",{"key":24,"text":600,"correct":26},"排水横管连接清扫口的连接管径应与清扫口同径",{"key":28,"text":602,"correct":22},"通气立管的管径应与排水立管同径",{"key":31,"text":604,"correct":26},"非寒冷地区伸顶通气管的管径宜与排水立管同径",{"id":606,"libraryId":5,"type":15,"typeLabel":16,"stem":607,"options":608,"answer":86,"analysis":34},879685,"下列关于雨水回用系统处理工艺设计的叙述中。哪几项正确？( )",[609,611,613,615],{"key":20,"text":610,"correct":22},"雨水回用系统处理工艺应设置消毒工艺",{"key":24,"text":612,"correct":26},"雨水蓄水池兼做沉淀池时，可按平流式沉淀池设计",{"key":28,"text":614,"correct":22},"雨水回用系统处理能力应为雨水日回用量除以处理设施日运行时间",{"key":31,"text":616,"correct":26},"同时设有雨水回用系统和中水系统时，处理系统宜分设，供水系统可合用",[618,622,625,628,631,634],{"id":619,"name":620,"category":7,"favorite":621},1,"领导干部任职前廉政法规知识测试题",92,{"id":623,"name":624,"category":7,"favorite":619},595,"建筑结构与设备",{"id":626,"name":627,"category":7,"favorite":619},715,"招标采购专业知识与法律法规",{"id":629,"name":630,"category":7,"favorite":619},848,"市政方向-通用基础",{"id":632,"name":633,"category":7,"favorite":8},534,"BIM工程师",{"id":635,"name":633,"category":7,"favorite":8},535]