[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-568-20":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":619},{"id":5,"name":6,"category":7,"favorite":8},568,"专业知识（给排水）","建筑工程",0,20,50,1213,[13,35,48,57,69,82,95,105,118,131,143,155,167,179,191,202,214,226,238,250,263,274,286,299,311,323,335,348,360,372,384,396,408,420,431,443,455,467,479,491,503,515,527,539,551,563,571,583,595,607],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},879586,2,"多选题","下列关于专用通气管的作用的叙述中，哪几项不正确？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","专用通气立管有利于平衡排水横支管的正负压",true,{"key":24,"text":25,"correct":26},"B","环形通气管可改善排水横支管的水流状况",false,{"key":28,"text":29,"correct":26},"C","设置结合通气管可影响排水立管的通水能力",{"key":31,"text":32,"correct":22},"D","专用通气立管有利于增大最低横支管与排水立管连接处至立管管底的垂直距离","AD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},879587,"下列关于气体灭火系统设计技术条件的叙述中，哪几项错误？( )",[39,41,43,45],{"key":20,"text":40,"correct":26},"某库房存放75%数量的可燃物品的设计灭火浓度为5.1%，其余可燃物品的设计灭火浓度为7.1%，则库房按设计灭火浓度7.1%确定",{"key":24,"text":42,"correct":22},"一个组合分配系统保护9个防护区，灭火剂储存量按最大防护区确定",{"key":28,"text":44,"correct":26},"某较大防护区采用两套管网设计，其喷头流量均应按同一灭火浓度同一喷放时间设计",{"key":31,"text":46,"correct":22},"系统因超过72小时才能恢复工作，其灭火剂储存量应按灭火剂用量、管网内剩余量之和确定","BD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":56,"analysis":34},879588,"下列生活给水水箱的配管及附件设置示意图中，哪几个图不符合要求？( )",[52,53,54,55],{"key":20,"text":34,"correct":22},{"key":24,"text":34,"correct":26},{"key":28,"text":34,"correct":22},{"key":31,"text":34,"correct":26},"AC",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":47,"analysis":34},879589,"在公共建筑内设置饮水器时，下列哪些叙述是正确的？( )",[61,63,65,67],{"key":20,"text":62,"correct":26},"饮水器的喷嘴应垂直安装并设防护装置",{"key":24,"text":64,"correct":22},"同组喷嘴的压力应一致",{"key":28,"text":66,"correct":26},"饮水器应采用与饮水管道相同的材质，其表面应光洁易于清洗",{"key":31,"text":68,"correct":22},"应设循环管道，循环回水应经消毒处理",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":81,"analysis":34},879590,"下列有关建筑中水处理系统设计要求的描述中，哪几项错误？( )",[73,75,77,79],{"key":20,"text":74,"correct":22},"原水为优质杂排水时，可不设格栅",{"key":24,"text":76,"correct":22},"原水为生活污水时，一般应设一道格栅",{"key":28,"text":78,"correct":26},"原水为杂排水时，设置原水调节池后可不再设初次沉淀池",{"key":31,"text":80,"correct":22},"原水为洗浴排水时，污水泵吸水管上设置毛发聚集器后，处理系统可取消格栅","ABD",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":94,"analysis":34},879591,"建筑排水可分为建筑生活排水系统、工业废水排水系统和屋面雨水排水系统。下列关于上述排水系统的说法中，哪几项正确？( )",[86,88,90,92],{"key":20,"text":87,"correct":22},"工业废水排水包括生产废水和生活污水",{"key":24,"text":89,"correct":22},"生活排水包括工业建筑及其管理用房等的生活废水和生活污水",{"key":28,"text":91,"correct":26},"厂房、车间的生产废水、生产污水排水流量应根据生产工艺确定",{"key":31,"text":93,"correct":26},"工业建筑与民用建筑屋面雨水流量及其雨水排水系统计算方法不同","AB",{"id":96,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":97,"answer":47,"analysis":34},879592,[98,100,101,103],{"key":20,"text":99,"correct":26},"污水设计流量采用10L\u002Fs",{"key":24,"text":34,"correct":22},{"key":28,"text":102,"correct":26},"隔油池的过流断面积最小为2㎡",{"key":31,"text":104,"correct":22},"过流断面采用正方形，有效水深最小为0.6m",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":117,"analysis":34},879593,"以下高层建筑热水供应系统设计方案说明中，哪几项技术是不合理的？( )",[109,111,113,115],{"key":20,"text":110,"correct":26},"热水供应系统分区与给水系统分区相一致，为确保出水温度恒定，根据业主要求增设恒温式水龙头",{"key":24,"text":112,"correct":22},"建筑高度140m，热水供应系统分四个区，各区自成系统，加热设备、循环水泵集中设在地下室，以便于运行中的统一管理",{"key":28,"text":114,"correct":22},"建筑层数24层，热水供应系统按层数均分为四个区，每个分区设置6根立管组成上行下给式管网，采用干管循环方式",{"key":31,"text":116,"correct":26},"为提高供水安全可靠性，考虑循环管路的双向供水，可放大回水管管径，使其与配水管管径接近","BC",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":130,"analysis":34},879594,"以下关于干式室内消火栓系统的叙述中，哪几项是正确的？( )",[122,124,126,128],{"key":20,"text":123,"correct":26},"室内环境温度低于4℃时，为防止管内结冰，必须采用干式消火栓系统",{"key":24,"text":125,"correct":22},"由电动阀控制的干式消火栓灭火系统启动时，其开启时间不应超过30s",{"key":28,"text":127,"correct":22},"为使干式系统快速充水转换成湿式系统，在系统管道的最高处应设置快速排气阀",{"key":31,"text":129,"correct":22},"干式系统的管网充水时间不应大于5min","BCD",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":56,"analysis":34},879595,"某小区的城市自来水引入管上设置了倒流防止器，建筑内的下列给水设施中，哪几种情况下还应采取防回流污染的措施？( )",[135,137,139,141],{"key":20,"text":136,"correct":22},"高位生活水箱的淹没进水管",{"key":24,"text":138,"correct":26},"生活热水热交换器的进水管",{"key":28,"text":140,"correct":22},"从建筑引入管上直接抽水的消防泵吸水管上",{"key":31,"text":142,"correct":26},"从建筑引入管上直接抽水的生活泵吸水管上",{"id":144,"libraryId":5,"type":15,"typeLabel":16,"stem":145,"options":146,"answer":94,"analysis":34},879596,"下列关于建筑生活热水供应系统的说法中，哪几项不正确？( )",[147,149,151,153],{"key":20,"text":148,"correct":22},"闭式热水供应系统必须设置膨胀罐",{"key":24,"text":150,"correct":22},"单管热水供应系统是指不设循环管道的热水供应系统",{"key":28,"text":152,"correct":26},"营业时间段不间断供应热水，即可称作全日制热水供应系统",{"key":31,"text":154,"correct":26},"开式热水供应系统适用于对冷热水压力平衡要求较高的建筑",{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":56,"analysis":34},879597,"下列关于建筑排水系统的叙述中，哪几项正确？( )",[159,161,163,165],{"key":20,"text":160,"correct":22},"排水分流制是指生活污水与生活废水或生产污水与生产废水设置独立的排水系统",{"key":24,"text":162,"correct":26},"工厂的生活污水与生产废水应采用分流制排水系统",{"key":28,"text":164,"correct":22},"生活排水采用分流制排水可减少化粪池容积",{"key":31,"text":166,"correct":26},"医院污水应采用分流制排水系统",{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":94,"analysis":34},879598,"下列关于建筑生活给水系统管道布置、敷设及附件选用的叙述中，哪几项正确？( )",[171,173,175,177],{"key":20,"text":172,"correct":22},"敷设在管井内的给水立管与其他立管之间的净距应满足维修要求",{"key":24,"text":174,"correct":22},"要求塑料给水管道在室内采用暗设，主要是因为塑料管被撞击后易损坏",{"key":28,"text":176,"correct":26},"宾馆引入管上设置的水表宜按其给水系统设计秒流量选用水表的常用流量",{"key":31,"text":178,"correct":26},"速闭消声止回阀可安装在水平管上，也可安装在水流方向自下而上的立管上",{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":181,"options":182,"answer":47,"analysis":34},879599,"关于游泳池循环水的净化处理工艺设计，下列哪几项正确？( )",[183,185,187,189],{"key":20,"text":184,"correct":26},"过滤器罐体承受压力不宜小于0.8MPa",{"key":24,"text":186,"correct":22},"单层石英砂滤料过滤器宜采用气、水组合反冲洗",{"key":28,"text":188,"correct":26},"过滤器应根据游泳池池水水质的实时监测结果确定其每天所需的运行时间",{"key":31,"text":190,"correct":22},"与双层或三层滤料过滤相比，单层石英砂滤料压力过滤器所需的反冲洗强度较低",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":193,"answer":81,"analysis":34},879600,[194,196,198,200],{"key":20,"text":195,"correct":22},"每根消防竖管的管径均不应小于150mm",{"key":24,"text":197,"correct":22},"每台水泵出水管的流量不应小于30L\u002Fs",{"key":28,"text":199,"correct":26},"消防水箱的最低有效水位应保证最不利点处消火栓栓口的静水压力≥0.10MPa",{"key":31,"text":201,"correct":22},"环状管网中的所有阀门必须设信号阀",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":47,"analysis":34},879601,"在A类火灾场所，不适合选用的灭火器类型是下述哪几项？( )",[206,208,210,212],{"key":20,"text":207,"correct":26},"磷酸铵盐干粉灭火器",{"key":24,"text":209,"correct":22},"碳酸氢铵干粉灭火器",{"key":28,"text":211,"correct":26},"泡沫灭火器",{"key":31,"text":213,"correct":22},"二氧化碳灭火器",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":56,"analysis":34},879602,"以下关于生活热水用水定额的叙述中，哪几项不符合要求？( )",[218,220,222,224],{"key":20,"text":219,"correct":22},"建筑热水用水定额的计算温度即为该建筑热水系统的供水温度",{"key":24,"text":221,"correct":26},"卫生器具小时用水定额的计算温度即为该卫生器具的使用温度",{"key":28,"text":223,"correct":22},"同一建筑内生活用水的冷水和热水用水定额相同",{"key":31,"text":225,"correct":26},"同类宿舍不论采用全日或定时热水供应方式，其最高日用水定额相同",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":117,"analysis":34},879603,"某电子计算机房分成三个防护区，采用七氟丙烷气体组合分配灭火系统，下列该系统灭火剂储存量的说明中，哪几项是正确的？( )",[230,232,234,236],{"key":20,"text":231,"correct":26},"按三个防护区所需总储存量计算",{"key":24,"text":233,"correct":22},"按三个防护区中储存量最大的一个防护区所需储存量计算",{"key":28,"text":235,"correct":22},"灭火剂储存量应为最大防护区的灭火剂设计用量、储存容器及管网内灭火剂剩余量之和",{"key":31,"text":237,"correct":26},"灭火剂储存量均应按系统原储存量的100%设置备用量",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":94,"analysis":34},879604,"某盥洗室排水横支管的设计秒流量为0.41L\u002Fs，选用DN50排水铸铁管，下列哪几项的i值不能作为确定其坡度的依据？( )",[242,244,246,248],{"key":20,"text":243,"correct":22},"1-0.01",{"key":24,"text":245,"correct":22},"1=0.015",{"key":28,"text":247,"correct":26},"1-0.025",{"key":31,"text":249,"correct":26},"1-0.035",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":262,"analysis":34},879605,"下述有关游泳池水消毒的设计要求中，哪几项是正确的？( )",[254,256,258,260],{"key":20,"text":255,"correct":26},"采用成品次氯酸钠溶液时，应避光贮、运，贮存时间不宜超过10d",{"key":24,"text":257,"correct":26},"采用瓶装氯气消毒时，投加量为1～3mg\u002FL，严禁将氯直接注入泳池内，加氯机组可根据泳池运行要求设置或不设置备用机组",{"key":28,"text":259,"correct":22},"采用紫外线消毒时，应辅以氯消毒",{"key":31,"text":261,"correct":22},"宾馆游泳池宜采用臭氧消毒，并应辅以氯消毒","CD",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":265,"answer":81,"analysis":34},879606,[266,268,270,272],{"key":20,"text":267,"correct":22},"系统灭火剂设计用量按指挥中心设计用量确定",{"key":24,"text":269,"correct":22},"指挥中心的主机房、活动地板及吊顶内分别设一套管网",{"key":28,"text":271,"correct":26},"系统共设置5组启动钢瓶(其中，指挥中心设置3组启动钢瓶)",{"key":31,"text":273,"correct":22},"通向配电房、指挥中心、数据处理机房的主管道上分别设置选择阀、压力讯号器",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":33,"analysis":34},879607,"下列关于中水水质的叙述中，哪几项不符合我国现行中水水质标准要求？( )",[278,280,282,284],{"key":20,"text":279,"correct":22},"城市杂用水和景观环境用水的再生水水质指标中对总氮无要求",{"key":24,"text":281,"correct":26},"中水用于消防、建筑施工时，其水质应按消防用水水质要求确定",{"key":28,"text":283,"correct":26},"城市杂用水水质指标中对水的含油量无要求",{"key":31,"text":285,"correct":22},"与城市杂用水其他用途相比，冲厕用水对阴离子表面活性剂的要求最严格",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":298,"analysis":34},879608,"以下有关同一建筑集中热水供应系统设计小时热媒耗量的叙述中，哪几项不正确？( )",[290,292,294,296],{"key":20,"text":291,"correct":22},"以蒸汽为热媒时，不论采用间接或直接加热方式，其热媒耗量相同",{"key":24,"text":293,"correct":22},"以高温热水为热媒间接加热时，热媒的初温和终温差值大则热媒耗量大(热媒管网热损失附加系数为定值)",{"key":28,"text":295,"correct":22},"采用容积式水加热器加热时，其容积大的较容积小的热媒耗量大",{"key":31,"text":297,"correct":26},"采用半即热式水加热器加热时，其热媒耗量较采用导流型容积式水加热器大","ABC",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":262,"analysis":34},879609,"某建筑生活给水系统采用“水泵—高位水箱—配水点”的供水方式。下列关于该系统高位水箱配管管径的叙述中，哪几项正确？( )",[303,305,307,309],{"key":20,"text":304,"correct":26},"高位水箱出水管管径按水泵设计出水量计算确定",{"key":24,"text":306,"correct":26},"高位水箱泄水管管径与水箱容积有关",{"key":28,"text":308,"correct":22},"高位水箱进水管管径按水泵设计出水量计算确定",{"key":31,"text":310,"correct":22},"高位水箱溢流管管径可按比水箱进水管管径大一级确定",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":81,"analysis":34},879610,"规定游泳池进水口流速的目的，主要是基于下列哪几项原因？( )",[315,317,319,321],{"key":20,"text":316,"correct":22},"保证循环流量",{"key":24,"text":318,"correct":22},"保证池水表面平稳",{"key":28,"text":320,"correct":26},"保证余氯投加均匀",{"key":31,"text":322,"correct":22},"保证游泳者的安全",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":81,"analysis":34},879611,"一栋设有地下室的9层住宅，卫生间采用De110塑料排水立管，厨房采用De75塑料排水立管，立管均明设。下列哪几项排水设计正确？( )",[327,329,331,333],{"key":20,"text":328,"correct":22},"卫生间排水立管穿楼板可不设防火套管",{"key":24,"text":330,"correct":22},"排水立管在地下室与排出管的连接处设支墩",{"key":28,"text":332,"correct":26},"阳台的雨水排入厨房排水立管中",{"key":31,"text":334,"correct":22},"排水立管管段连接采用橡胶密封圈，立管上可不不设伸缩节",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":347,"analysis":34},879612,"下列有关建筑生活排水局部处理设施设计选型、设计参数及设置要求等的说法中，哪几项正确？( )",[339,341,343,345],{"key":20,"text":340,"correct":22},"当降温池冷却水采用城市自来水时，应采取防回流污染措施",{"key":24,"text":342,"correct":26},"当隔油池或隔油器设在室内时，应设置通向室外的通气管",{"key":28,"text":344,"correct":22},"医院生活污水在化粪池中的停留时间宜大于住宅生活污水的停留时间",{"key":31,"text":346,"correct":22},"无论采用两格或三格化粪池，其第一格(沿水流方向)的容积均最大","ACD",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":347,"analysis":34},879613,"关于建筑排水管道的布置与敷设，下面哪些项是正确的？( )",[352,354,356,358],{"key":20,"text":353,"correct":22},"阳台地漏同时接纳雨水和洗衣机排水时应接至生活排水管道系统",{"key":24,"text":355,"correct":26},"医院无菌手术室的地面排水应采取间接排水方式",{"key":28,"text":357,"correct":22},"饮食业厨房及备餐的上方不得布置排水横管",{"key":31,"text":359,"correct":22},"集体宿舍盥洗室及淋浴间内应设置地漏",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":347,"analysis":34},879614,"下列关于建筑热水开式系统的说法中，哪几项不正确？( )",[364,366,368,370],{"key":20,"text":365,"correct":22},"开式系统的热水供水压力取决于冷水系统的供水压力",{"key":24,"text":367,"correct":26},"开式系统的热水供水压力不受室外给水供水压力的影响",{"key":28,"text":369,"correct":22},"开式系统中应设置膨胀罐或高位冷水箱",{"key":31,"text":371,"correct":22},"开式系统中膨胀管是适用于补偿设备和管道内水容积的膨胀量",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":347,"analysis":34},879615,"下列关于管道直饮水处理的说法中，哪几项正确？( )",[376,378,380,382],{"key":20,"text":377,"correct":22},"用于管道直饮水消毒的方法有臭氧、紫外线、氯消毒等",{"key":24,"text":379,"correct":26},"采用氯消毒时，产品水中氯残留浓度不应大于0.01mg\u002FL",{"key":28,"text":381,"correct":22},"膜技术是用于深度净化直饮水的一种主要方法",{"key":31,"text":383,"correct":22},"常用的管道直饮水处理工艺流程是：预处理一膜处理一后处理",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":130,"analysis":34},879616,"下列关于建筑屋面雨水排水系统设计的叙述中，哪几项正确？( )",[388,390,392,394],{"key":20,"text":389,"correct":26},"高层建筑屋面雨水排水宜按满管压力流设计",{"key":24,"text":391,"correct":22},"重力流雨水悬吊管管径(公称直径)不应小于100mm",{"key":28,"text":393,"correct":22},"多层建筑重力流雨水排水系统宜采用建筑排水塑料管",{"key":31,"text":395,"correct":22},"屋面雨水排水管道设计降雨历时应按5min计算",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":33,"analysis":34},879617,"下列关于建筑灭火器配置设计的说法中，哪几项不正确？( )",[400,402,404,406],{"key":20,"text":401,"correct":22},"灭火剂不应采用卤代烷灭火剂",{"key":24,"text":403,"correct":26},"最不利点处应至少在1具灭火器的保护范围内",{"key":28,"text":405,"correct":26},"灭火器可设置在室外，但应采用相应的保护措施",{"key":31,"text":407,"correct":22},"灭火器配置场所的危险等级与其自动喷水灭火系统设置场所的危险等级相同",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":56,"analysis":34},879618,"以下关于灭火器选型和配置的叙述，正确的是哪几项？( )",[412,414,416,418],{"key":20,"text":413,"correct":22},"磷酸铵盐干粉和碳酸氢钾干粉灭火器，不可用于同一配置场所",{"key":24,"text":415,"correct":26},"当同一灭火器配置场所，存在不同火灾种类时，不应选用通用型灭火器",{"key":28,"text":417,"correct":22},"有条件时，也可在同一场所内同时选配手提式灭火器和推车式灭火器",{"key":31,"text":419,"correct":26},"卤代烷灭火器已淘汰，所有场所均不得选配",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":422,"answer":56,"analysis":34},879619,[423,425,427,429],{"key":20,"text":424,"correct":22},"P1～P2管段：DN100mm，i=0.012",{"key":24,"text":426,"correct":26},"P3～P4管段：DN150mm，i=0.007",{"key":28,"text":428,"correct":22},"P6～P7管段：DN300mm，i=0.003",{"key":31,"text":430,"correct":26},"P7～P8管段：DN300mm，i=0.003",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":117,"analysis":34},879620,"以下有关水加热设备选择的叙述中，哪几项是错误的？( )",[435,437,439,441],{"key":20,"text":436,"correct":26},"容积式水加热设备被加热水侧的压力损失宜≤0.01MPa",{"key":24,"text":438,"correct":22},"医院热水供应系统设置2台不加热设备时，为确保手术室热水供水安全，一台检修时，另一台的供热能力不得小于设计小时耗热量",{"key":28,"text":440,"correct":22},"局部热水供应设备同时给多个卫生器具供热水时，因瞬时负荷不大，宜采用即热式加热设备",{"key":31,"text":442,"correct":26},"热水用水较均匀，热媒供应能力充足，可选用半容积式水加热器",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":347,"analysis":34},879621,"游泳池可采用石英砂过滤器或硅藻土过滤器对池水进行循环净化处理，关于石英砂过滤器、硅藻土过滤器特点的叙述中，哪几项正确？( )",[447,449,451,453],{"key":20,"text":448,"correct":22},"当采用硅藻土过滤器时，可不投加絮凝剂",{"key":24,"text":450,"correct":26},"对于石英砂过滤器，只要其进、出口压差小于0.06MPa就可不进行反冲洗",{"key":28,"text":452,"correct":22},"对于板框式硅藻土过滤器，其进、出口压差小于0.07MPa时不需进行反冲洗",{"key":31,"text":454,"correct":22},"当采用石英砂过滤器时，既可采用压力过滤方式，也可采用重力过滤方式",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":298,"analysis":34},879622,"七氟丙烷及IG541混合气体灭火系统进行一次灭火的设计灭火剂储存量，应按下列哪几项之和进行确定？( )",[459,461,463,465],{"key":20,"text":460,"correct":22},"防护区的灭火设计用量",{"key":24,"text":462,"correct":22},"储存容器内的灭火剂剩余量",{"key":28,"text":464,"correct":22},"管网内的灭火剂剩余量",{"key":31,"text":466,"correct":26},"按系统储存要求设置的备用量",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":347,"analysis":34},879623,"某宾馆(350床)高区生活给水系统拟采用如下供水方案：方案一：市政供水管→低位贮水池→变频增压设备→配水点。方案二：市政供水管→低位贮水池→增压水泵→高位水箱→配水点。下列关于上述方案一、方案二比较的叙述中，哪几项正确？( )",[471,473,475,477],{"key":20,"text":472,"correct":22},"方案一、方案二的市政进水管设计流量可相同",{"key":24,"text":474,"correct":26},"方案一、方案二的增压供水设备设计流量可相同",{"key":28,"text":476,"correct":22},"方案一、方案二的低位贮水池设计有效容积可相同",{"key":31,"text":478,"correct":22},"方案一、方案二的生活给水系统配水管网设计流量可相同",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":56,"analysis":34},879624,"以下作为节点流量计入居住小区的室外生活给水管道设计流量的表述哪几项正确？( )",[483,485,487,489],{"key":20,"text":484,"correct":22},"居住小区内的绿化用水、道路洒水以平均时用水量计算节点流量",{"key":24,"text":486,"correct":26},"居住小区内的幼儿园、物业管理以最大时用水量计算节点流量",{"key":28,"text":488,"correct":22},"居住小区内配套的健身中心、商铺按设计秒流量还是按最大时用水量计算节点流量是由居住小区内服务人数决定的",{"key":31,"text":490,"correct":26},"居住小区内住宅应按设计秒流量计算节点流量",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":347,"analysis":34},879625,"以下哪几项不能作为计算居住小区给水设计用水量的依据？( )",[495,497,499,501],{"key":20,"text":496,"correct":22},"居住小区给水设计最高日用水量应包括消防用水量",{"key":24,"text":498,"correct":26},"居住小区给水设计最高日用水量包括居住小区内的公共建筑用水量",{"key":28,"text":500,"correct":22},"居住小区给水的未预见水量按最高日用水量的10%～15%计",{"key":31,"text":502,"correct":22},"居住小区内重大公用设施的用水量应由某管理部门提出",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":81,"analysis":34},879626,"下列有关中水处理工艺的叙述中，哪几项是正确的？( )",[507,509,511,513],{"key":20,"text":508,"correct":22},"通常生物处理为中水处理的主体工艺",{"key":24,"text":510,"correct":22},"无论何种中水处理工艺，流程中均需设置消毒设施",{"key":28,"text":512,"correct":26},"中水处理工艺可分为预处理和主处理两大部分",{"key":31,"text":514,"correct":22},"当原水为杂排水时，设置调节池后，可不再设初次沉淀池",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":298,"analysis":34},879627,"以下各类污废水的排放要求中，哪几项是不正确的？( )",[519,521,523,525],{"key":20,"text":520,"correct":22},"生产废水均不能排入生产厂房的雨水排水系统",{"key":24,"text":522,"correct":22},"洗车台的冲洗水可与建筑小区雨水排水系统合流排出",{"key":28,"text":524,"correct":22},"工业企业中除屋面雨水外的其他污废水均可通过生产废水排水系统排出",{"key":31,"text":526,"correct":26},"用作中水水源的生活排水应单独排出",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":298,"analysis":34},879628,"下列中水处理工艺流程中，哪几项是不完善、不合理的？( )",[531,533,535,537],{"key":20,"text":532,"correct":22},"优质杂排水→格栅→调节池→生物处理→过滤→中水",{"key":24,"text":534,"correct":22},"优质杂排水→调节池→絮凝沉淀→过滤→消毒→中水",{"key":28,"text":536,"correct":22},"生活污水→格栅→渗滤场→消毒→中水",{"key":31,"text":538,"correct":26},"污水厂二级处理出水→调节池→气浮→过滤→消毒→中水",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":117,"analysis":34},879629,"下列哪几种消防设施更适于建筑内部人员使用扑救初期火灾而自救逃生？( )",[543,545,547,549],{"key":20,"text":544,"correct":26},"消火栓",{"key":24,"text":546,"correct":22},"手提式灭火器",{"key":28,"text":548,"correct":22},"消防卷盘",{"key":31,"text":550,"correct":26},"火灾报警器",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":81,"analysis":34},879630,"建筑小区室外绿化和景观采用同一水源，以下哪些水源可以利用？( )",[555,557,559,561],{"key":20,"text":556,"correct":22},"市政中水",{"key":24,"text":558,"correct":22},"收集小区的雨水",{"key":28,"text":560,"correct":26},"小区自备地下井水",{"key":31,"text":562,"correct":22},"收集建筑内的空调系统冷凝水",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":117,"analysis":34},879631,"某小区室外给水管采用内衬水泥的铸铁管，管径200mm，管道计算内径202mm，与单体建筑引入管采用三通连接，管件内径与管道内径一致，其沿程与局部水头损失∑i的合理取值应选哪几个计算式(式中Qg为给水设计流量)？( )",[567,568,569,570],{"key":20,"text":34,"correct":26},{"key":24,"text":34,"correct":22},{"key":28,"text":34,"correct":22},{"key":31,"text":34,"correct":26},{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":47,"analysis":34},879632,"计算全日制机械循环热水系统的循环流量时，与之有关的是下列哪几项？( )",[575,577,579,581],{"key":20,"text":576,"correct":26},"热水系统的热水供水量",{"key":24,"text":578,"correct":22},"热水配水管道的热损失",{"key":28,"text":580,"correct":26},"热水回水管道的热损失",{"key":31,"text":582,"correct":22},"热水配水管道中水的温度差",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":117,"analysis":34},879633,"判断下列说法中，哪几项正确？( )",[587,589,591,593],{"key":20,"text":588,"correct":26},"管道直饮水满足《生活饮用水卫生标准》GB5749-2006的要求即可",{"key":24,"text":590,"correct":22},"建筑中水可用于厕所冲洗",{"key":28,"text":592,"correct":22},"生活饮用水可用于洗车",{"key":31,"text":594,"correct":26},"消防用水对水质没有要求",{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":56,"analysis":34},879634,"建筑排水系统采用硬聚氯乙烯排水管，下列关于其伸缩节设置要求中，哪几项是错误的？( )",[599,601,603,605],{"key":20,"text":600,"correct":22},"排水横管上的伸缩节应设于水流汇合管件的下游端",{"key":24,"text":602,"correct":26},"埋地排水管道上可不设伸缩节",{"key":28,"text":604,"correct":22},"排水立管穿越楼层处为固定支承时，伸缩节应同时固定",{"key":31,"text":606,"correct":26},"伸缩节插口应顺水流方向",{"id":608,"libraryId":5,"type":15,"typeLabel":16,"stem":609,"options":610,"answer":33,"analysis":34},879635,"以下有关高层建筑生活给水系统的叙述中，哪几项不准确？( )",[611,613,615,617],{"key":20,"text":612,"correct":22},"高层建筑生活给水系统应采用水泵加压供水",{"key":24,"text":614,"correct":26},"高层建筑生活给水系统可不设高位水箱",{"key":28,"text":616,"correct":26},"高层建筑的划分标准并不依给水系统的特性确定",{"key":31,"text":618,"correct":22},"高层建筑生活给水系统的配水管网应设成环状",[620,624,627,630,633,636],{"id":621,"name":622,"category":7,"favorite":623},1,"领导干部任职前廉政法规知识测试题",92,{"id":625,"name":626,"category":7,"favorite":621},595,"建筑结构与设备",{"id":628,"name":629,"category":7,"favorite":621},715,"招标采购专业知识与法律法规",{"id":631,"name":632,"category":7,"favorite":621},848,"市政方向-通用基础",{"id":634,"name":635,"category":7,"favorite":8},534,"BIM工程师",{"id":637,"name":635,"category":7,"favorite":8},535]