[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-568-19":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":620},{"id":5,"name":6,"category":7,"favorite":8},568,"专业知识（给排水）","建筑工程",0,19,50,1213,[13,35,48,61,74,86,99,111,123,135,147,159,171,184,196,208,221,234,245,257,269,281,294,306,318,330,342,355,367,379,390,402,410,422,434,446,458,470,482,494,506,518,530,542,554,562,574,585,596,608],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},879536,2,"多选题","下列哪几项是排水通气管的主要作用？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","保护卫生器具水封",true,{"key":24,"text":25,"correct":26},"B","增加立管内水流速度",false,{"key":28,"text":29,"correct":26},"C","为室内卫生间透气",{"key":31,"text":32,"correct":22},"D","增加排水立管的排水能力","AD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},879537,"下述高层建筑生活给水系统水压的要求中，哪几项符合规定？( )",[39,41,43,45],{"key":20,"text":40,"correct":22},"系统各分区最低卫生器具配水点处静水压力不宜大于0.45MPa",{"key":24,"text":42,"correct":26},"静水压力大于0.35MPa的人户管应设减压措施",{"key":28,"text":44,"correct":22},"卫生器具给水配件承受的最大工作压力不得大于0.6MPa",{"key":31,"text":46,"correct":26},"竖向分区的最大水压应是卫生器具正常使用的最佳水压","AC",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},879538,"关于直饮水制备及水质防护措施，下列哪几项不正确？( )",[52,54,56,58],{"key":20,"text":53,"correct":26},"集中式直饮水系统供回水管网循环周期不应超过12h",{"key":24,"text":55,"correct":22},"直饮水管道系统中可选用与管道材料不同的管件",{"key":28,"text":57,"correct":26},"集中式直饮水处理站处理出水的余氯浓度为0.01mg\u002FL",{"key":31,"text":59,"correct":22},"集中式直饮水处理站处理出水的臭氧浓度不得大于0.01mg\u002FL","BD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},879539,"某建筑高区生活给水系统拟采用以下三种供水方案：方案①：市政供水管→叠压供水设备→系统用水点；方案②：市政供水管→调节水池→变频供水设备→系统用水点；方案③：市政供水管→调节水池→水泵→高位水箱→系统用水点；下列关于上述供水设计方案比选的叙述中，哪几项正确？( )",[65,67,69,71],{"key":20,"text":66,"correct":22},"供水水量可靠、水压稳定性：③＞②＞①",{"key":24,"text":68,"correct":22},"供水水质保证程度：①＞②＞③",{"key":28,"text":70,"correct":22},"系统控制复杂程度，方案①、②相同，但均比方案③复杂",{"key":31,"text":72,"correct":26},"配水管网的设计供水量：方案①、②相同，但均比方案③高","ABC",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":47,"analysis":34},879540,"要求防火分隔水幕形成密集喷洒的水墙时，该水幕系统应选用以下何种喷头？( )",[78,80,82,84],{"key":20,"text":79,"correct":22},"水幕喷头",{"key":24,"text":81,"correct":26},"水雾喷头",{"key":28,"text":83,"correct":22},"开式洒水喷头",{"key":31,"text":85,"correct":26},"闭式洒水喷头",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":98,"analysis":34},879541,"高层建筑室内明设排水系统采用硬聚氯乙烯排水管道设置阻火圈，下列设置要求中哪几项是正确的？( )",[90,92,94,96],{"key":20,"text":91,"correct":26},"设置阻火圈的硬聚氯乙烯排水管外径大于等于90mm",{"key":24,"text":93,"correct":26},"排水横管穿越防火墙时，应在其一侧设置防火圈",{"key":28,"text":95,"correct":22},"排水立管穿越楼板时，应在其下方设置防火圈",{"key":31,"text":97,"correct":22},"排水支管接入排水立管穿越管道井壁(管井隔层设防火封堵)时，应在井壁处设置防火圈","CD",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":60,"analysis":34},879542,"某高层住宅排水系统按下列要求设计，哪几项错误？( )",[103,105,107,109],{"key":20,"text":104,"correct":26},"厨房专用排水立管可不设置通气立管",{"key":24,"text":106,"correct":22},"厨房排水排入隔壁卫生间的洗浴废水立管",{"key":28,"text":108,"correct":26},"厨房排水可不经隔油处理直接排入室外污水管网",{"key":31,"text":110,"correct":22},"厨房应设置地漏",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":60,"analysis":34},879543,"下列有关建筑给水系统设计的说法中，哪几项正确？( )",[115,117,119,121],{"key":20,"text":116,"correct":26},"生活给水干管局部水头损失可按沿程水头损失的百分数取值",{"key":24,"text":118,"correct":22},"给水设计秒流量与生活给水系统管网的压力大小无关",{"key":28,"text":120,"correct":26},"住宅建筑生活给水设计秒流量与卫生器具给水当量有关，与使用人数无关",{"key":31,"text":122,"correct":22},"室外生活、消防合用给水管，其管径不得小于100mm",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":60,"analysis":34},879544,"关于通气管管径，以下设计计算哪些项正确？( )",[127,129,131,133],{"key":20,"text":128,"correct":26},"连接1根DN00mm污水立管和1根DN75mm废水立管的专用通气立管，其最小管径应为DN100mm",{"key":24,"text":130,"correct":22},"排水横支管管径为DN100mm，其环形通气管的最小管径可取DN50mm",{"key":28,"text":132,"correct":26},"连接1根DN125mm排水立管的自循环通气立管，其管径取100mm",{"key":31,"text":134,"correct":22},"高档酒店卫生间浴盆排水管上设器具通气管，其最小管径可取DN32mm",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":33,"analysis":34},879545,"下列关于排水当量的叙述中，哪几项错误？( )",[139,141,143,145],{"key":20,"text":140,"correct":22},"大便器冲洗阀的排水当量受给水压力影响",{"key":24,"text":142,"correct":26},"6个排水当量的累加流量等于2.0L\u002Fs",{"key":28,"text":144,"correct":26},"浴盆的排水当量比大便器的排水当量小",{"key":31,"text":146,"correct":22},"淋浴器的排水当量对应的流量与其给水当量对应的流量相同",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":73,"analysis":34},879546,"中水处理系统由下列哪几部分组成？( )",[151,153,155,157],{"key":20,"text":152,"correct":22},"预处理",{"key":24,"text":154,"correct":22},"主处理",{"key":28,"text":156,"correct":22},"后处理",{"key":31,"text":158,"correct":26},"回用系统",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":60,"analysis":34},879547,"下列关于建筑生活给水系统防止水质污染设计中，哪几项错误？( )",[163,165,167,169],{"key":20,"text":164,"correct":26},"在生活饮用水贮水池内设置导流隔墙",{"key":24,"text":166,"correct":22},"地下生活饮用水贮水池的底板、池壁共用地下室的底板、外墙",{"key":28,"text":168,"correct":26},"由建筑高位水箱向其热水机组注水的进水管上不设倒流防止器",{"key":31,"text":170,"correct":22},"高位生活饮用水贮水池溢流管和放空管的合用排出管与雨水排水管连接",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":183,"analysis":34},879548,"环形通气管与通气立管应在卫生器具上边缘以上不少于0.15m处按不小于0.01的上升坡度与通气立管相连，其主要原因为下列哪几项？( )",[175,177,179,181],{"key":20,"text":176,"correct":26},"便于管道的施工维护",{"key":24,"text":178,"correct":22},"便于发现管道堵塞",{"key":28,"text":180,"correct":22},"利于防止污水进入通气管",{"key":31,"text":182,"correct":26},"利于立管横向支管补气","BC",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":73,"analysis":34},879549,"以下关于环形通气管、器具通气管、主通气立管、副通气立管、专用通气立管作用和确定其管径的叙述中，哪几项正确？( )",[188,190,192,194],{"key":20,"text":189,"correct":22},"上述通气管均可改善其服务排水管的水流状态",{"key":24,"text":191,"correct":22},"上述通气管均能起到保护卫生器具水封的作用",{"key":28,"text":193,"correct":22},"上述通气管管径均与其服务的排水管管径无关",{"key":31,"text":195,"correct":26},"上述通气管管径均与其服务的建筑物建筑高度无关",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":183,"analysis":34},879550,"下列关于高层建筑消火栓系统的高位消防水箱设置高度的说明中，哪几项错误？( )",[200,202,204,206],{"key":20,"text":201,"correct":26},"某高层办公楼从室外地面到檐口的高度为100m，其高位消防水箱最低水位与最不利消火栓口高度≥7m",{"key":24,"text":203,"correct":22},"某高层住宅从室内地面到檐口的高度为100m，其高位消防水箱的设置高度应保证最不利消火栓处静水压≥7m",{"key":28,"text":205,"correct":22},"某建筑高度为120m的旅馆，其高位消防水箱最高水位至最不利消火栓口高度应≥15m",{"key":31,"text":207,"correct":26},"某建筑高度为120m的旅馆，其高位消防水箱最低水位至最不利消火栓栓口距离仅为10m，应设增压装置",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":220,"analysis":34},879551,"关于建筑排水系统选择，以下哪些项不正确？( )",[212,214,216,218],{"key":20,"text":213,"correct":22},"当小区不设雨水利用设施时，建筑雨水排水系统可不单独设置",{"key":24,"text":215,"correct":22},"机械自动洗车台排水含有大量泥沙，应先经预处理后排至化粪池",{"key":28,"text":217,"correct":26},"大学学生食堂的厨房排水，应排至除油池进行预处理",{"key":31,"text":219,"correct":22},"环保要求生活污水经化粪池预处理时，生活废水应单独直排市政排水管网","ABD",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":233,"analysis":34},879552,"下列关于雨水收集回用系统处理工艺设计的描述中，哪几项错误？( )",[225,227,229,231],{"key":20,"text":226,"correct":26},"雨水蓄水池可兼做沉淀池",{"key":24,"text":228,"correct":22},"应结合雨水可生化性好的特征合理选择处理工艺",{"key":28,"text":230,"correct":22},"雨水用作景观水体的补水时应设置消毒工艺",{"key":31,"text":232,"correct":22},"非种植屋面雨水可不设置初期径流雨水弃流设施","BCD",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":236,"answer":220,"analysis":34},879553,[237,239,241,243],{"key":20,"text":238,"correct":22},"排出管管径可减小至DN100",{"key":24,"text":240,"correct":22},"排水立管与排出管采用两个45°弯头连接",{"key":28,"text":242,"correct":26},"一层横支管排入PL-2可行，但二层横支管不能排入PL-1",{"key":31,"text":244,"correct":22},"排水横支管与排水立管可采用90°顺水三通或45°斜三通连接",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":233,"analysis":34},879554,"以下关于游泳池设施的描述中，哪些是正确的？( )",[249,251,253,255],{"key":20,"text":250,"correct":26},"室内游泳馆设有成人池、儿童池以及幼儿戏水池，其中儿童池和幼儿戏水池共用一套池水循环净化设备，净化后的池水经分水器分别接至儿童池及幼儿戏水池",{"key":24,"text":252,"correct":22},"水上游乐池滑道润滑系统的循环水泵，设置两台，一用一备",{"key":28,"text":254,"correct":22},"混合流式循环给水方式的游泳池应设置均衡水池",{"key":31,"text":256,"correct":22},"某游泳池给水口沿25m长的两侧壁等距布置，共设置18个给水口",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":98,"analysis":34},879555,"下列关于水喷雾灭火系统的叙述中，哪几项错误？( )",[261,263,265,267],{"key":20,"text":262,"correct":26},"水喷雾灭火系统可采用闭式喷头探测火灾",{"key":24,"text":264,"correct":26},"水喷雾灭火系统可用于保护油浸式电力变压器",{"key":28,"text":266,"correct":22},"水喷雾灭火系统采用组合分配系统时，防护区数量不应超过8个",{"key":31,"text":268,"correct":22},"水喷雾喷头可采用开式喷头或闭式喷头灭火",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":33,"analysis":34},879556,"以下有关机械循环集中热水供应系统管网计算的叙述中，哪几项是错误的？( )",[273,275,277,279],{"key":20,"text":274,"correct":22},"定时热水供应系统的循环流量应按供水时段内循环管网中的水循环2～4次计算",{"key":24,"text":276,"correct":26},"居住小区集中热水供应系统室外热水干管设计流量的计算，与居住小区室外给水管道设计流量的计算方法相同",{"key":28,"text":278,"correct":26},"计算导流型容积式水加热器循环水泵扬程时，可不计加热器的水头损失",{"key":31,"text":280,"correct":22},"选择循环水泵时，其水泵壳体承受的工作压力应以水泵扬程确定",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":293,"analysis":34},879557,"干式自动喷水系统的配水管道充有压气体的目的，是下列哪几项？( )",[285,287,289,291],{"key":20,"text":286,"correct":22},"将有压气体作为传递火警信号的介质",{"key":24,"text":288,"correct":22},"防止干式报警阀误动作",{"key":28,"text":290,"correct":26},"检测管道的严密性",{"key":31,"text":292,"correct":26},"快速启动系统","AB",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":73,"analysis":34},879558,"为防止建筑生活热水供应系统中被热水烫伤事故的发生，下列哪几项措施正确？( )",[298,300,302,304],{"key":20,"text":299,"correct":22},"控制水加热设备出水温度与最不利配水点温差≤10℃",{"key":24,"text":301,"correct":22},"保证混合龙头用水点处冷、热水压力的平衡与稳定",{"key":28,"text":303,"correct":22},"在用水终端装设安全可靠的调控阀件",{"key":31,"text":305,"correct":26},"热水供、回水管道采用同程布置",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":220,"analysis":34},879559,"以下有关中水水质和水源要求的叙述中，哪几项是正确的？( )",[310,312,314,316],{"key":20,"text":311,"correct":22},"中水的用途不同，其水质要求也不相同",{"key":24,"text":313,"correct":22},"水质满足洗车要求的中水，也可用于冲洗厕所",{"key":28,"text":315,"correct":26},"医院污水不能作为中水水源",{"key":31,"text":317,"correct":22},"屋面雨水可作为中水水源",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":73,"analysis":34},879560,"某高层建筑消火栓给水系统拟采用下列防超压措施，哪几项正确？( )",[322,324,326,328],{"key":20,"text":323,"correct":22},"提高管道和附件的承压能力",{"key":24,"text":325,"correct":22},"在消防水泵出水管上设置泄压阀",{"key":28,"text":327,"correct":22},"在消火栓给水系统管道上设置安全阀",{"key":31,"text":329,"correct":26},"选用流量扬程曲线较陡的消防水泵",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":33,"analysis":34},879561,"下列有关地漏设置的叙述中，哪几项错误？( )",[334,336,338,340],{"key":20,"text":335,"correct":22},"住宅建筑的厨房地面上应设地漏",{"key":24,"text":337,"correct":26},"多通道地漏可将同一卫生间浴盆和洗脸盆的排水一并接入",{"key":28,"text":339,"correct":26},"住宅卫生间地面设置地漏时应选用密闭地漏",{"key":31,"text":341,"correct":22},"住宅阳台上放置洗衣机时，允许只设雨水地漏与洗衣机排水合并排放雨水系统",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":354,"analysis":34},879562,"下列消防用水水源的叙述中，不正确的是哪几项？( )",[346,348,350,352],{"key":20,"text":347,"correct":22},"消防用水只能由城市给水管网、消防水池供给",{"key":24,"text":349,"correct":26},"消防用水可由保证率≥97%，且设有可靠取水设施的天然水源供给",{"key":28,"text":351,"correct":22},"消防用水采用季节性天然水源供给时，其保证率不得小于90%，且天然水源处设可靠取水设施",{"key":31,"text":353,"correct":22},"消防用水不能由天然水源供给","ACD",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":354,"analysis":34},879563,"以下关于室内排水管、通气管管材的选用的叙述中，哪几项正确？( )",[359,361,363,365],{"key":20,"text":360,"correct":22},"压力排水管道可采用耐压塑料管、金属管或钢塑复合管",{"key":24,"text":362,"correct":26},"排水管道设置的清扫口应与管道相同材质",{"key":28,"text":364,"correct":22},"通气管管材可采用塑料管，柔性接口机制排水铸铁管",{"key":31,"text":366,"correct":22},"连续排水温度大于40℃时，应采用金属排水管或耐热塑料排水管",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":73,"analysis":34},879564,"下列关于水泵接合器和室外消火栓设计的叙述中，哪几项错误？( )",[371,373,375,377],{"key":20,"text":372,"correct":22},"墙壁消防水泵接合器距其墙面上的窗的净距为1.5m",{"key":24,"text":374,"correct":22},"十层住宅当设有室内消火栓时可不设室外消火栓",{"key":28,"text":376,"correct":22},"水泵接合器的数量应按室内外消防用水量之和计算确定",{"key":31,"text":378,"correct":26},"建筑室外消火栓的数量根据室外消火栓设计流量和保护半径计算确定",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":381,"answer":354,"analysis":34},879565,[382,384,386,388],{"key":20,"text":383,"correct":22},"采用重力流的屋面雨水排水管系中的埋地排出横管",{"key":24,"text":385,"correct":26},"采用压力流的屋面雨水排水管系中的埋地排出横管",{"key":28,"text":387,"correct":22},"小区雨水排水管系中的埋地横管",{"key":31,"text":389,"correct":22},"小区生活排水管系中的埋地横管",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":354,"analysis":34},879566,"下列哪些排水管不能与污废水管道系统直接连接？( )",[394,396,398,400],{"key":20,"text":395,"correct":22},"食品库房地面排水管",{"key":24,"text":397,"correct":26},"锅炉房地面排水管",{"key":28,"text":399,"correct":22},"热水器排水管",{"key":31,"text":401,"correct":22},"阳台雨水排水管",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":60,"analysis":34},879567,"依据图中文字说明判别下列哪些自动喷水灭火系统是错误的？( )",[406,407,408,409],{"key":20,"text":34,"correct":26},{"key":24,"text":34,"correct":22},{"key":28,"text":34,"correct":26},{"key":31,"text":34,"correct":22},{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":354,"analysis":34},879568,"下列哪些情况不适用直接加热开式太阳能热水供应系统？( )",[414,416,418,420],{"key":20,"text":415,"correct":22},"冷水供水硬度大于150mg\u002FL",{"key":24,"text":417,"correct":26},"公共浴室",{"key":28,"text":419,"correct":22},"冰冻地区",{"key":31,"text":421,"correct":22},"宾馆客房、医院病房的卫生间淋浴",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":183,"analysis":34},879569,"下列关于热水供应系统的热源选择说法中，哪几项错误？( )",[426,428,430,432],{"key":20,"text":427,"correct":26},"集中热水供应系统利用工业废热时，废气、烟气温度不宜低于400℃",{"key":24,"text":429,"correct":22},"北方冬季采暖地区，当无条件利用工业余热、废热、地热或太阳能等热源时，宜优先采用热力管网",{"key":28,"text":431,"correct":22},"日照时数大于1400h\u002F年且年太阳辐射量大于4200MJ\u002Fm的地区宜优先采用太阳能",{"key":31,"text":433,"correct":26},"局部热水供应系统宜采用太阳能、电能等",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":293,"analysis":34},879570,"某水上游乐中心建有：a-比赛池；b-形状不规则，分浅深水区的公共游泳池；c-儿童池。以下各类池子所选池水循环方式哪几项是正确合理的？( )",[438,440,442,444],{"key":20,"text":439,"correct":22},"a～逆流式，b～顺流式，c～直流式",{"key":24,"text":441,"correct":22},"a～混流式，b～顺流式，c～直流式",{"key":28,"text":443,"correct":26},"a～顺流式，b～逆流式，c～混流式",{"key":31,"text":445,"correct":26},"a～逆流式，b～逆流式，c～顺流式",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":354,"analysis":34},879571,"以下关于自动喷水灭火系统喷头选型设计的叙述中，哪几项正确？( )",[450,452,454,456],{"key":20,"text":451,"correct":22},"吊顶下布置的喷头，应采用下垂型喷头或吊顶型喷头",{"key":24,"text":453,"correct":26},"预作用系统必须采用直立型喷头",{"key":28,"text":455,"correct":22},"自动喷水一泡沫联用系统应采用洒水喷头",{"key":31,"text":457,"correct":22},"雨淋系统的防护区内，应采用相同的喷头",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":233,"analysis":34},879572,"下列雨水利用供水系统的设计要求中，哪几项是正确合理的？( )",[462,464,466,468],{"key":20,"text":463,"correct":26},"雨水供水管与生活饮用水管的连接管上必须设置倒流防止器",{"key":24,"text":465,"correct":22},"雨水供水系统中应设有自动补水设施",{"key":28,"text":467,"correct":22},"采用再生水作雨水供水系统补水时，其水质不能低于雨水供水水质",{"key":31,"text":469,"correct":22},"雨水供水管道上不得装设取水龙头",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":33,"analysis":34},879573,"下列关于饮用净水的设计要求中，哪几项是正确的？( )",[474,476,478,480],{"key":20,"text":475,"correct":22},"优先选用无高位水箱的供水系统",{"key":24,"text":477,"correct":26},"高层建筑饮用供水系统采用减压阀分区时，阀前应设置截污器",{"key":28,"text":479,"correct":26},"从配水立管接至配水龙头的管道长度不宜超过4m",{"key":31,"text":481,"correct":22},"管网最高处设置带有滤菌、防尘装置的排气阀",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":60,"analysis":34},879574,"居住区公用绿地浇洒采用中水时，下列哪些污水可作为中水水源？( )",[486,488,490,492],{"key":20,"text":487,"correct":26},"结核病防治所污水",{"key":24,"text":489,"correct":22},"营业餐厅的厨房污水",{"key":28,"text":491,"correct":26},"经消毒的综合医院污水",{"key":31,"text":493,"correct":22},"办公楼粪便污水",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":233,"analysis":34},879575,"下列关于小区雨水利用系统的说法中，哪几项不正确？( )",[498,500,502,504],{"key":20,"text":499,"correct":26},"雨水收集回用系统可削减小区外排雨水径流总量",{"key":24,"text":501,"correct":22},"雨水调蓄排放系统可削减小区外排雨水径流总量",{"key":28,"text":503,"correct":22},"设有景观水体的小区雨水利用应优先考虑用于景观水体的补充",{"key":31,"text":505,"correct":22},"小区雨水收集回用系统宜用于年平均降雨量小于400mm的地区",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":220,"analysis":34},879576,"下列关于建筑生活给水系统节水设计措施或说法中，哪几项措施欠合理或说法不正确？( )",[510,512,514,516],{"key":20,"text":511,"correct":22},"自闭式水嘴、脚踏开关、球阀均属于节水型给水器材",{"key":24,"text":513,"correct":22},"给水设备、器材如水泵、水表等的使用年限一般在10～15a",{"key":28,"text":515,"correct":26},"对采用节水器具的建筑生活给水系统，可适当降低其生活用水定额",{"key":31,"text":517,"correct":22},"在高位水箱供水立管上沿水流方向串联设置中、低区给水系统减压阀",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":233,"analysis":34},879577,"下列哪些水不能接入屋面雨水立管？( )",[522,524,526,528],{"key":20,"text":523,"correct":26},"屋面雨水",{"key":24,"text":525,"correct":22},"阳台雨水",{"key":28,"text":527,"correct":22},"建筑污水",{"key":31,"text":529,"correct":22},"建筑废水",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":73,"analysis":34},879578,"下列关于水喷雾灭火系统的表述中，哪几项正确？( )",[534,536,538,540],{"key":20,"text":535,"correct":22},"水喷雾灭火系统是雨淋系统的一种形式",{"key":24,"text":537,"correct":22},"水喷雾灭火系统可扑救电器火灾",{"key":28,"text":539,"correct":22},"水喷雾灭火系统可设置为局部灭火系统",{"key":31,"text":541,"correct":26},"水喷雾灭火系统应配置加压水泵",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":47,"analysis":34},879579,"某高层住宅高区生活给水系统拟采用如下供水方式：方案一：地下贮水池→恒压变频供水设备→高区用水点；方案二：地下贮水池→水泵→高位水箱→高区用水点。下列关于上述供水设计方案比选的叙述中，哪几项正确？( )",[546,548,550,552],{"key":20,"text":547,"correct":22},"方案一加压供水设备总功率大于方案二",{"key":24,"text":549,"correct":26},"方案一加压供水设备总功率小于方案二",{"key":28,"text":551,"correct":22},"方案一加压供水设备设计流量大于方案二",{"key":31,"text":553,"correct":26},"方案一加压供水设备设计流量小于方案二",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":293,"analysis":34},879580,"某车间生产设备不允许间断供水，其给水系统采用市政水源及自备水源双水源供水，下列哪些设计方案图是可行的？( )",[558,559,560,561],{"key":20,"text":34,"correct":22},{"key":24,"text":34,"correct":22},{"key":28,"text":34,"correct":26},{"key":31,"text":34,"correct":26},{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":60,"analysis":34},879581,"下列关于建筑生活排水管道的布置及管材、附件选用的叙述中，哪几项正确？( )",[566,568,570,572],{"key":20,"text":567,"correct":26},"建筑内部排水管管材的选用应根据排水水质确定",{"key":24,"text":569,"correct":22},"建筑内部的排水立管和排水横管均应考虑设置伸缩节",{"key":28,"text":571,"correct":26},"建筑内部排水管道附件如检查口、清扫口等材质应与其排水管道同材质",{"key":31,"text":573,"correct":22},"当厨房烹调或备餐间的上方设有卫生间时，其卫生间应采用同层排水方式",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":183,"analysis":34},879582,"下列有关集中热水供应系统水加热设备设计小时供热量计算的叙述中，哪几项是错误的？( )",[578,580,582,583],{"key":20,"text":579,"correct":26},"半即热式水加热器，当供热量按设计秒流量供应，并设有可靠的温度自控装置时，可不设贮热水箱",{"key":24,"text":581,"correct":22},"热水机组直接供热时，供热量按设计小时耗热量计算",{"key":28,"text":34,"correct":22},{"key":31,"text":584,"correct":26},"半容积式水加热器的供热量按设计小时耗热量计算",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":98,"analysis":34},879583,"当加热设备间断排放热废水时，下列有关降温池容积计算的叙述中，哪几项不正确？( )",[589,591,593,595],{"key":20,"text":590,"correct":26},"承压锅炉排放热废水时，其降温池有效容积应至少是热废水排放量与冷却水量容积之和，并考虑混合不均匀系数",{"key":24,"text":592,"correct":26},"热废水的蒸发量与热废水的热焓有关",{"key":28,"text":594,"correct":22},"承受锅炉的工作压力越大，热废水的蒸发量越小",{"key":31,"text":34,"correct":22},{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":33,"analysis":34},879584,"某20层办公楼，层高3.0m，分高、中、低三层供水，低区为-2～4层，中区5～12层，高区13～20层，分区后各区最低层卫生器具配水点静水压力均小于350kPA以下叙述哪几项是正确的？( )",[600,602,604,606],{"key":20,"text":601,"correct":22},"该楼各区最低层卫生器具配水点静水压力符合分区要求",{"key":24,"text":603,"correct":26},"该楼各区最低层卫生器具配水点静水压力不符合分区要求",{"key":28,"text":605,"correct":26},"分区后能满足各层卫生器具配水点最佳使用压力要求",{"key":31,"text":607,"correct":22},"分区后不能满足各层卫生器具配水点最佳使用压力要求",{"id":609,"libraryId":5,"type":15,"typeLabel":16,"stem":610,"options":611,"answer":47,"analysis":34},879585,"以下关于屋顶消防水箱设置的叙述中，哪几项不准确？( )",[612,614,616,618],{"key":20,"text":613,"correct":22},"高层建筑必须设置屋顶消防水箱",{"key":24,"text":615,"correct":26},"对仅设置室内消火栓系统的高层工业厂房，当必须设置屋顶消防水箱时，消防水箱设置在该厂房的最高部位",{"key":28,"text":617,"correct":22},"屋顶消防水箱的设置高度应满足室内最不利点处消火栓灭火时的计算压力",{"key":31,"text":619,"correct":26},"屋顶消防水箱的主要作用是提供初期火灾时的消防用水水量",[621,625,628,631,634,637],{"id":622,"name":623,"category":7,"favorite":624},1,"领导干部任职前廉政法规知识测试题",92,{"id":626,"name":627,"category":7,"favorite":622},595,"建筑结构与设备",{"id":629,"name":630,"category":7,"favorite":622},715,"招标采购专业知识与法律法规",{"id":632,"name":633,"category":7,"favorite":622},848,"市政方向-通用基础",{"id":635,"name":636,"category":7,"favorite":8},534,"BIM工程师",{"id":638,"name":636,"category":7,"favorite":8},535]