[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-568-18":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":618},{"id":5,"name":6,"category":7,"favorite":8},568,"专业知识（给排水）","建筑工程",0,18,50,1213,[13,35,47,60,73,85,98,110,123,135,147,159,172,185,197,209,222,234,247,259,271,283,295,307,318,330,341,352,364,376,383,395,402,414,426,438,450,462,474,486,498,510,522,534,546,558,570,582,594,606],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},879486,2,"多选题","某城市源水输水管线路中途有一高地，其高程正好与最大输水流量时的水力坡降线标高相同，为保证在各种工况下管道不出现负压，可采取以下哪几种措施？( )",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","开凿隧洞通过高地，降低管道埋设标高",true,{"key":24,"text":25,"correct":22},"B","减少输送流量，降低水头损失",{"key":27,"text":28,"correct":22},"C","管线绕道通过高地，总水头损失不增加",{"key":30,"text":31,"correct":32},"D","加大高地至净水厂管道管径",false,"ABC","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":33,"analysis":34},879487,"下列有关生活热水水质的叙述中，哪几项是不正确的？( )",[39,41,43,45],{"key":20,"text":40,"correct":22},"洗衣房和浴室所供热水总硬度的控制值应相同",{"key":24,"text":42,"correct":22},"当生活热水的硬度下降至75mg\u002FL(以碳酸钙计)以下时，更利于热水的使用",{"key":27,"text":44,"correct":22},"当生活热水的硬度下降至75mg\u002FL(以碳酸钙计)以下时，更利于管道的维护",{"key":30,"text":46,"correct":32},"为控制热水硬度，设计中也可按比例将部分软化水与非软化水混合使用",{"id":48,"libraryId":5,"type":15,"typeLabel":16,"stem":49,"options":50,"answer":59,"analysis":34},879488,"下列关于管道直饮水系统的叙述，正确的是哪几项？( )",[51,53,55,57],{"key":20,"text":52,"correct":22},"管道直饮水应对原水进行深度净化处理",{"key":24,"text":54,"correct":22},"管道直饮水系统必须独立设置",{"key":27,"text":56,"correct":32},"管道直饮水系统必须采用调速泵组直接供水",{"key":30,"text":58,"correct":22},"管道直饮水系统应设循环管道，其供回水管网应同程布置","ABD",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":72,"analysis":34},879489,"下列关于设计小时耗热量的说法中，哪几项正确？( )",[64,66,68,70],{"key":20,"text":65,"correct":22},"热水用水定额低、使用人数少时，小时变化系数取高值",{"key":24,"text":67,"correct":32},"热水供应系统热水量的小时变化系数大于给水系统的小时变化系数",{"key":27,"text":69,"correct":22},"全日与定时热水供应系统的设计小时耗热量，其计算方法不同",{"key":30,"text":71,"correct":32},"某办公楼热水使用时间为8h，设计小时耗热量应按定时供应系统计算","AC",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":59,"analysis":34},879490,"下列关于加(贮)热设备的布置，哪几项不正确？( )",[77,79,81,83],{"key":20,"text":78,"correct":22},"空气源热泵机组的风机噪声大，应置于密闭的设有隔离材料的房间内",{"key":24,"text":80,"correct":22},"开式系统中冷水补给水箱最高设计水位应高于热水箱的最高设计水位",{"key":27,"text":82,"correct":32},"太阳能集热器的布置应保证每天4h的日照时间",{"key":30,"text":84,"correct":22},"热水机组一般露天布置，以使气流条件良好",{"id":86,"libraryId":5,"type":15,"typeLabel":16,"stem":87,"options":88,"answer":97,"analysis":34},879491,"下列建筑和居住小区排水体制的选择中，哪几项是不正确的？( )",[89,91,93,95],{"key":20,"text":90,"correct":32},"新建居住小区室外有市政排水管道时，应采用分流制排水系统",{"key":24,"text":92,"correct":22},"新建居住小区室外暂无市政排水管道时，应采用合流制排水系统",{"key":27,"text":94,"correct":22},"居住小区内建筑的排水体制应与小区排水体制相一致",{"key":30,"text":96,"correct":32},"生活污水需初步处理后才允许排入市政管道时，建筑排水系统应采用分流制排水系统","BC",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":59,"analysis":34},879492,"下列关于建筑热水供应系统的说法中，哪几项错误？( )",[102,104,106,108],{"key":20,"text":103,"correct":22},"闭式热水供应系统应设泄压阀",{"key":24,"text":105,"correct":22},"闭式热水供应系统中，膨胀罐的总容积与冷热水温度无关",{"key":27,"text":107,"correct":32},"开式热水供应系统中，膨胀管的设置高度与热水系统的大小无关",{"key":30,"text":109,"correct":22},"热水系统由生活冷水高位水箱补水时，可将其膨胀管引至其高位水箱上空",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":122,"analysis":34},879493,"在饮用净水系统中，下列哪几项措施可起到水质防护作用？( )",[114,116,118,120],{"key":20,"text":115,"correct":32},"各配水点均采用额定流量为0.04L\u002Fs的专用水嘴",{"key":24,"text":117,"correct":22},"采用变频给水机组直接供水",{"key":27,"text":119,"correct":22},"饮水系统设置循环管道",{"key":30,"text":121,"correct":22},"控制饮水在管道内的停留时间不超过5h","BCD",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":59,"analysis":34},879494,"关于耗热量与加热设备供热量，下列哪几项错误？( )",[127,129,131,133],{"key":20,"text":128,"correct":22},"半容积式水加热器的设计小时供热量应不大于设计小时耗热量",{"key":24,"text":130,"correct":22},"快速式水加热器的设计小时供热量按设计小时耗热量取值",{"key":27,"text":132,"correct":32},"导流型容积式水加热器的设计小时供热量不应小于平均小时耗热量",{"key":30,"text":134,"correct":22},"水源热泵设计小时供热量与设计小时耗热量无关",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":33,"analysis":34},879495,"下列有关高层建筑群共用消防水池、水箱的设计要求中，哪几项是正确的？( )",[139,141,143,145],{"key":20,"text":140,"correct":22},"共用消防水池、水箱的高层建筑群，同一时间内只考虑一次火灾",{"key":24,"text":142,"correct":22},"共用消防水池的容积应按该建筑群中用水量最大一幢建筑的消防用水量计算确定",{"key":27,"text":144,"correct":22},"确定消防水池水深时，应考虑建设场地的海拔高度",{"key":30,"text":146,"correct":32},"共用消防水池贮存室外消防用水量时，其取水口距被保护建筑外墙的距离不宜小于6m",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":72,"analysis":34},879496,"判断下列哪些系统应按现行《自动喷水灭火系统设计规范》设计？( )",[151,153,155,157],{"key":20,"text":152,"correct":22},"雨淋灭火系统",{"key":24,"text":154,"correct":32},"水喷雾灭火系统",{"key":27,"text":156,"correct":22},"防火分隔水幕系统",{"key":30,"text":158,"correct":32},"自动水炮灭火系统",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":171,"analysis":34},879497,"某单位一幢多层普通办公楼拟配置灭火器，下列哪几种灭火器适用于该建筑？( )",[163,165,167,169],{"key":20,"text":164,"correct":32},"二氧化碳灭火器",{"key":24,"text":166,"correct":22},"泡沫灭火器",{"key":27,"text":168,"correct":32},"碳酸氢钠干粉灭火器",{"key":30,"text":170,"correct":22},"磷酸铵盐干粉灭火器","BD",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":184,"analysis":34},879498,"某单层棉花仓库，占地面积800㎡，建筑高度4m，以下关于该建筑消防灭火设施的设置，叙述正确的是哪几项？( )",[176,178,180,182],{"key":20,"text":177,"correct":22},"应设置室内外消火栓系统，可不设置自动喷水灭火系统",{"key":24,"text":179,"correct":22},"室内、外消火栓设计流量分别为15L\u002Fs、25L\u002Fs",{"key":27,"text":181,"correct":32},"室内消火栓系统必须设置水泵接合器",{"key":30,"text":183,"correct":32},"消火栓系统加压泵不应设置备用泵","AB",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":33,"analysis":34},879499,"下列自动喷水灭火系统组件与设施的连接管中，管径不应小于DN25的是哪几项？( )",[189,191,193,195],{"key":20,"text":190,"correct":22},"与DN15直立型喷头连接的短立管",{"key":24,"text":192,"correct":22},"与DN15下垂型喷头连接的短立管",{"key":27,"text":194,"correct":22},"末端试水装置的连接管",{"key":30,"text":196,"correct":32},"水力警铃与报警阀间的连接管",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":72,"analysis":34},879500,"自动喷水灭火系统报警阀器控制喷头数的主要原因是下列哪几项？( )",[201,203,205,207],{"key":20,"text":202,"correct":22},"提高系统的可靠性",{"key":24,"text":204,"correct":32},"控制系统设计流量不致过大",{"key":27,"text":206,"correct":22},"避免系统维修时的关停部分不致过大",{"key":30,"text":208,"correct":32},"避免喷头布置时与防火分区面积相差过大",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":221,"analysis":34},879501,"关于游泳池的消毒，下列哪几项做法不符合要求？( )",[213,215,217,219],{"key":20,"text":214,"correct":32},"游泳池必须设置池水消毒工艺",{"key":24,"text":216,"correct":32},"消毒设备的投加系统应能自动控制",{"key":27,"text":218,"correct":22},"采用臭氧消毒应设置活性炭吸附罐",{"key":30,"text":220,"correct":22},"输送臭氧气体的管道、阀门、附件应采用306L或316L不锈钢材质","CD",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":97,"analysis":34},879502,"下列关于水喷雾灭火系统水雾喷头选型设计的叙述中，哪几项不正确？( )",[226,228,230,232],{"key":20,"text":227,"correct":32},"扑救电气火灾应选用离心雾化型水雾喷头",{"key":24,"text":229,"correct":22},"用于扑救闪点高于60℃的液体火灾选用中速喷头",{"key":27,"text":231,"correct":22},"用于防护冷却容器的选用高速喷头",{"key":30,"text":233,"correct":32},"有粉尘场所设置的水雾喷头应设有防尘罩",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":246,"analysis":34},879503,"下列某二类高层建筑写字楼按A类火灾场所设置灭火器的选择中，哪几项是正确的？( )",[238,240,242,244],{"key":20,"text":239,"correct":22},"设灭火级别为2A的手提式磷酸铵盐干粉灭火器，保护距离为20m",{"key":24,"text":241,"correct":32},"设灭火级别为1A的手提式磷酸铵盐干粉灭火器，保护距离为15m",{"key":27,"text":243,"correct":32},"设灭火级别为2A的手提式磷酸铵盐干粉灭火器，保护距离为40m",{"key":30,"text":245,"correct":22},"设灭火级别为2A的手提式磷酸铵盐干粉灭火器，保护距离为15m","AD",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":221,"analysis":34},879504,"下列关于自动喷水灭火系统的叙述中，哪几项不正确？( )",[251,253,255,257],{"key":20,"text":252,"correct":32},"雨淋报警阀不只限用于雨淋灭火系统",{"key":24,"text":254,"correct":32},"设有自动喷水灭火系统的房间，其吊顶内有时可不设喷头",{"key":27,"text":256,"correct":22},"预作用系统应在灭火喷头开启后立即自动向配水管道供水",{"key":30,"text":258,"correct":22},"配水管道的公称压力不应大于1.20MPa，并不应设置其他用水设施",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":171,"analysis":34},879505,"某地级市政府办公大楼的第3层由办公室(配有电脑、复印机等办公设备)、一个小型会议室和一个中型会议室(分设在走道两端)及走道组成，大楼设有集中空调，下列该楼层的灭火器配置设计中，哪几项正确？( )",[263,265,267,269],{"key":20,"text":264,"correct":32},"该楼层均按中危险级配置灭火器",{"key":24,"text":266,"correct":22},"办公室、走道按中危险级配置灭火器",{"key":27,"text":268,"correct":32},"将该楼层作为1个计算单元设计灭火器",{"key":30,"text":270,"correct":22},"应将该楼层分为3个计算单元设计灭火器",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":221,"analysis":34},879506,"某地下空间与城市交通隧道一体化建设，交通隧道总长度为1500m，可双向通行非危险品机动车。以下有关交通隧道内消防设施的设置，叙述错误的是哪几项？( )",[275,277,279,281],{"key":20,"text":276,"correct":32},"交通隧道内应设置消防给水系统",{"key":24,"text":278,"correct":32},"隧道内宜设置独立的消防给水系统；条件不允许时，可与地下空间设置共同的消防给水系统",{"key":27,"text":280,"correct":22},"隧道内消火栓系统设计流量不应小于10L\u002Fs",{"key":30,"text":282,"correct":22},"室内消火栓应设在隧道两侧墙的相同位置，且每侧墙的消火栓间距不大于50m",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":33,"analysis":34},879507,"下述有关游泳池池水及泄水管安装的要求中，哪几项是正确的？( )",[287,289,291,293],{"key":20,"text":288,"correct":22},"竞赛游泳池初次充水时间不超过48h",{"key":24,"text":290,"correct":22},"游泳池初次加热池水的时间不超过48h",{"key":27,"text":292,"correct":22},"游泳池泄水口重力泄水时，泄水管不得与排水管道连接",{"key":30,"text":294,"correct":32},"游泳池最小补充水量应以保证15d内池水全部更新一次计算",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":97,"analysis":34},879508,"某医院的配电机房内采用预制式七氟丙烷气体灭火系统，在机房对角各设置一套预制式七氟丙烷气体灭火系统装置，以下关于该装置的设计，哪几项错误？( )",[299,301,303,305],{"key":20,"text":300,"correct":32},"设自动控制和手动控制两种启动方式",{"key":24,"text":302,"correct":22},"每套装置上设置的气体喷头数量相同",{"key":27,"text":304,"correct":22},"每套装置的充压压力为4.2MPa",{"key":30,"text":306,"correct":32},"各装置能自行探测火灾并自动启动",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":309,"answer":184,"analysis":34},879509,[310,312,314,316],{"key":20,"text":311,"correct":22},"a=1.6m，b=3.6m",{"key":24,"text":313,"correct":22},"a=1.8m，b=3.6m",{"key":27,"text":315,"correct":32},"a=1.6m，b=3.7m",{"key":30,"text":317,"correct":32},"a=1.9m，b=3.4m",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":97,"analysis":34},879510,"某场所拟配置两种类型灭火器，下列哪几项配置错误？( )",[322,324,326,328],{"key":20,"text":323,"correct":32},"二氧化碳与卤代烷灭火器",{"key":24,"text":325,"correct":22},"碳酸氢钠与磷酸铵盐灭火器",{"key":27,"text":327,"correct":22},"蛋白泡沫与碳酸氢钠灭火器",{"key":30,"text":329,"correct":32},"水型灭火剂与水成膜泡沫灭火器",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":171,"analysis":34},879511,"下列关于室内消防给水管道和消火栓布置的说法中，哪几项正确？( )",[334,336,338,340],{"key":20,"text":335,"correct":32},"室内消防竖管直径不应小于DN100",{"key":24,"text":337,"correct":22},"消防电梯间前室内应设置消火栓",{"key":27,"text":339,"correct":32},"冷库内可不设置消火栓",{"key":30,"text":34,"correct":22},{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":351,"analysis":34},879512,"当市政给水管道为支状或只有一条进水管时，下列哪些建筑可不设消防水池？( )",[345,347,349,350],{"key":20,"text":346,"correct":22},"18层住宅楼",{"key":24,"text":348,"correct":32},"1650个座位的剧院",{"key":27,"text":34,"correct":22},{"key":30,"text":34,"correct":22},"ACD",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":72,"analysis":34},879513,"下列高层建筑消防给水系统竖向分区原则及水压的要求中，哪几项是正确的？( )",[356,358,360,362],{"key":20,"text":357,"correct":22},"室内消火栓栓口的静水压力不应超过1.0MPa",{"key":24,"text":359,"correct":32},"室内消火栓栓口的进水压力不应超过0.5MPa",{"key":27,"text":361,"correct":22},"自动喷水灭火系统报警阀出口压力不应超过1.2MPa",{"key":30,"text":363,"correct":32},"自动喷水灭火系统轻、中危险级场所配水管道入口压力不应超过0.4MPa",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":72,"analysis":34},879514,"游泳池循环水采用臭氧消毒时，下列哪几项说法不正确？( )",[368,370,372,374],{"key":20,"text":369,"correct":22},"臭氧投加量应按池水容积确定",{"key":24,"text":371,"correct":32},"臭氧消毒系统应设剩余臭氧吸附装置",{"key":27,"text":373,"correct":22},"由于臭氧的半衰期较长，宜辅以氯消毒",{"key":30,"text":375,"correct":32},"采用臭氧消毒时，应设臭氧一水混合器",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":378,"answer":221,"analysis":34},879515,[379,380,381,382],{"key":20,"text":34,"correct":32},{"key":24,"text":34,"correct":32},{"key":27,"text":34,"correct":22},{"key":30,"text":34,"correct":22},{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":97,"analysis":34},879516,"关于生活给水系统增压泵的描述，哪些是正确的？( )",[387,389,391,393],{"key":20,"text":388,"correct":32},"生活加压给水系统的水泵机组应设备用泵，备用泵的供水能力不应小于泵组的供水能力",{"key":24,"text":390,"correct":22},"建筑物内采用高位水箱调节的生活给水系统时，水泵的最大出水量不应小于最大小时用水量",{"key":27,"text":392,"correct":22},"生活给水系统采用调速泵组供水时，应按系统最大设计流量选泵",{"key":30,"text":394,"correct":32},"对水泵Q至H特性曲线存在上升段的水泵，任何情况下均不可采用",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":397,"answer":72,"analysis":34},879517,[398,399,400,401],{"key":20,"text":34,"correct":22},{"key":24,"text":34,"correct":32},{"key":27,"text":34,"correct":22},{"key":30,"text":34,"correct":32},{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":351,"analysis":34},879518,"下列关于建筑灭火器设置要求的叙述中，哪几项正确？( )",[406,408,410,412],{"key":20,"text":407,"correct":22},"一个计算单元内配置的灭火器数量不应少于2具",{"key":24,"text":409,"correct":32},"住宅建筑每层的公共部位应设置至少1具手提式灭火器",{"key":27,"text":411,"correct":22},"在A类火灾中危险级场所，单具Ms\u002F09型清水灭火器保护面积可达150㎡",{"key":30,"text":413,"correct":22},"E类火灾场所灭火器最低配置标准不应低于该场所内A类火灾的配置标准",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":59,"analysis":34},879519,"下列关于游泳池循环净化系统设计的叙述中，哪几项正确？( )",[418,420,422,424],{"key":20,"text":419,"correct":22},"池水采用逆流式循环时，应设置均衡水池",{"key":24,"text":421,"correct":22},"池水采用顺流式循环时，一般设置平衡水池",{"key":27,"text":423,"correct":32},"比赛或训练用游泳池池水只能采用混合式循环方式",{"key":30,"text":425,"correct":22},"池水采用混合式循环时，应设置均衡水池，符合一定条件下可设平衡水池",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":33,"analysis":34},879520,"下列有关自动喷水灭火系统设计的说法中，哪几项正确？( )",[430,432,434,436],{"key":20,"text":431,"correct":22},"宾馆客房可采用边墙型喷头",{"key":24,"text":433,"correct":22},"预作用系统可替代干式系统",{"key":27,"text":435,"correct":22},"无报警阀组的局部应用系统，其配水管可直接与室内消火栓给水立管连接",{"key":30,"text":437,"correct":32},"当仓库顶板下及货架内均设有喷头时，系统设计流量按两者之间的最大值确定",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":171,"analysis":34},879521,"下列关于建筑中水处理工艺设计的叙述中，哪几项错误？( )",[442,444,446,448],{"key":20,"text":443,"correct":32},"不论采用哪种中水处理工艺，均应设置原水调节构筑物",{"key":24,"text":445,"correct":22},"中水处理产生的污泥，当污泥量较大时，可直接排至化粪池处理",{"key":27,"text":447,"correct":32},"当原水为优质杂排水时，设置调节池后可不再设初次沉淀池",{"key":30,"text":449,"correct":22},"建筑物内部的小型中水处理站，宜优先采用液氯消毒",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":171,"analysis":34},879522,"建筑内部生活排水采用分流制的作用，包括以下哪几项？( )",[454,456,458,460],{"key":20,"text":455,"correct":32},"可减轻对小区室外雨水管道系统的污染",{"key":24,"text":457,"correct":22},"可减轻建筑内部生活污水处理设施的设计规模",{"key":27,"text":459,"correct":32},"可增加中水水源的可收集水量",{"key":30,"text":461,"correct":22},"可防止大便器排水造成的水封破坏",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":351,"analysis":34},879523,"为使高层建筑集中热水供应系统中生活热水和冷水给水系统的压力相近，可采取以下哪几项措施？( )",[466,468,470,472],{"key":20,"text":467,"correct":22},"使生活热水和冷水给水系统竖向分区供水的范围一致",{"key":24,"text":469,"correct":32},"热水供水管网采用同程布置方式",{"key":27,"text":471,"correct":22},"热水供水系统选用阻力损失较小的加热设备",{"key":30,"text":473,"correct":22},"系统配水点采用优质的冷、热水混合水嘴",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":33,"analysis":34},879524,"以下关于游泳池补水的叙述中，哪几项正确？( )",[478,480,482,484],{"key":20,"text":479,"correct":22},"大型公共游泳池采用生活饮用水向布水口直接补水时，其补水管上应设置倒流防止器",{"key":24,"text":481,"correct":22},"游泳池的充水管和补水管的管道上应分别设置独立的水量计量仪表",{"key":27,"text":483,"correct":22},"休闲游泳池的初次充水时间可以超过48h",{"key":30,"text":485,"correct":32},"游泳池运行中的补充水量根据蒸发量和过滤设备反冲洗消耗的水量确定",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":122,"analysis":34},879525,"某建筑内部生活排水管道设计，下列哪几项不正确？( )",[490,492,494,496],{"key":20,"text":491,"correct":32},"首层的排水沟不允许直接与室外排水管道连通",{"key":24,"text":493,"correct":22},"室内生活排水不可采用室内排水沟",{"key":27,"text":495,"correct":22},"排水横管与排水立管宜采用90°三通连接",{"key":30,"text":497,"correct":22},"塑料排水管道在穿越楼板处应设置伸缩节",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":351,"analysis":34},879526,"下列关于加热设备设计小时供热量与热水供应系统设计小时耗热量的叙述中，哪几项不正确？( )",[502,504,506,508],{"key":20,"text":503,"correct":22},"加热设备设计小时供热量是热水供应系统设计小时耗热量的计算依据",{"key":24,"text":505,"correct":32},"容积式水加热器的设计小时供热量小于热水供应系统设计小时耗热量",{"key":27,"text":507,"correct":22},"水源热泵机组的设计小时供热量与热水供应系统设计小时耗热量相同",{"key":30,"text":509,"correct":22},"太阳能热水供应系统的辅助热源设计小时供热量小于设计小时耗热量",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":72,"analysis":34},879527,"下列关于建筑热水系统管道布置、敷设和附件设置的叙述中，哪几项正确？( )",[514,516,518,520],{"key":20,"text":515,"correct":22},"热水立管与横管应采用乙字弯的连接方式",{"key":24,"text":517,"correct":32},"热水管道穿楼板加套管关键是为了保护管道",{"key":27,"text":519,"correct":22},"下行上给式热水系统配水干管上可不设排气阀",{"key":30,"text":521,"correct":32},"热水管道可直埋于楼板找平层内(但不应有接头)",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":171,"analysis":34},879528,"以下关于小区雨水排水系统的说法中，哪几项错误？( )",[526,528,530,532],{"key":20,"text":527,"correct":32},"小区雨水排水管道排水宜按满管重力流设计",{"key":24,"text":529,"correct":22},"小区雨水排水管道最小管径不宜小于DN300",{"key":27,"text":531,"correct":32},"小区雨水排水管道排水设计重现期宜为1～3a",{"key":30,"text":533,"correct":22},"小区重力流雨水排水管道满流时，其过水流量最大",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":122,"analysis":34},879529,"下列哪几项措施对防止污废水进入建筑排水系统通气管是有效的？( )",[538,540,542,544],{"key":20,"text":539,"correct":32},"将环形通气管在排水横支管始端的两个卫生器具间水平向接出",{"key":24,"text":541,"correct":22},"将环形通气管在排水横支管中心线以上垂直接出",{"key":27,"text":543,"correct":22},"将H管与通气立管的连接点置于卫生器具上边缘以上不小于0.15m处",{"key":30,"text":545,"correct":22},"控制伸顶通气管高出屋面的距离不小于0.3m且大于当地积雪厚度",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":59,"analysis":34},879530,"下列不同场所地漏的选用中，哪几项是正确合理的？( )",[550,552,554,556],{"key":20,"text":551,"correct":22},"地下通道选用防倒流地漏",{"key":24,"text":553,"correct":22},"公共食堂选用网框式地漏",{"key":27,"text":555,"correct":32},"地面不经常排水的场所选用直通式地漏",{"key":30,"text":557,"correct":22},"卫生标准要求高的场所选用密闭式地漏",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":221,"analysis":34},879531,"下列关于建筑中水处理设计，哪几项正确？( )",[562,564,566,568],{"key":20,"text":563,"correct":32},"建筑中水处理应在前段设置化粪池进行预处理",{"key":24,"text":565,"correct":32},"优质原水调节池可以代替二次沉淀池",{"key":27,"text":567,"correct":22},"小规模建筑中水处理系统产生的污泥允许排入化粪池处理",{"key":30,"text":569,"correct":22},"建筑中水处理可采用土地处理和曝气生物滤池处理",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":97,"analysis":34},879532,"关于在热水管网的管段上装设止回阀的部位，以下叙述正确的是哪几项？( )",[574,576,578,580],{"key":20,"text":575,"correct":32},"室内热水管道向公共卫生间接出的配水管的起端",{"key":24,"text":577,"correct":22},"水加热器或贮水罐的冷水供水管上",{"key":27,"text":579,"correct":22},"机械循环的第二循环系统回水管上",{"key":30,"text":581,"correct":32},"与配水、回水干管连接的分干管上",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":97,"analysis":34},879533,"下列关于建筑中水水源选择的叙述中，哪几项正确？( )",[586,588,590,592],{"key":20,"text":587,"correct":32},"医院排放的生活排水均可作为中水水源",{"key":24,"text":589,"correct":22},"以生活污水作为中水水源时，应经化粪池处理后方可进入中水原水系统",{"key":27,"text":591,"correct":22},"以厨房废水作为中水水源时，应经隔油池处理后方可进入中水原水系统",{"key":30,"text":593,"correct":32},"采用城镇污水厂二级处理后的出水作为中水水源时，不需要再处理而直接用于道路浇洒和绿地喷灌",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":33,"analysis":34},879534,"以下关于室内给水管道的布置叙述中，哪几项是错误或不合理的？( )",[598,600,602,604],{"key":20,"text":599,"correct":22},"室内给水管道宜成环状布置，以保证安全供水",{"key":24,"text":601,"correct":22},"室内冷、热水管布置时，冷水管应位于热水管的下方或左侧",{"key":27,"text":603,"correct":22},"给水管不得敷设在电梯井内、排水沟内，且不宜穿越风道、橱窗和橱柜",{"key":30,"text":605,"correct":32},"给水管不宜穿越伸缩缝、沉降缝或变形缝",{"id":607,"libraryId":5,"type":15,"typeLabel":16,"stem":608,"options":609,"answer":221,"analysis":34},879535,"下列有关中水系统水源选择的叙述中，哪几项是错误的？( )",[610,612,614,616],{"key":20,"text":611,"correct":32},"建筑屋面雨水可作为中水水源",{"key":24,"text":613,"correct":32},"小区雨水不宜引入室内作为建筑中水水源",{"key":27,"text":615,"correct":22},"城市污水处理厂的出水作为小区中水水源时，均可接入小区中水管道直接使用",{"key":30,"text":617,"correct":22},"以综合医院消毒处理后的污水为原水的中水系统，产出的中水可冲洗汽车",[619,623,626,629,632,635],{"id":620,"name":621,"category":7,"favorite":622},1,"领导干部任职前廉政法规知识测试题",92,{"id":624,"name":625,"category":7,"favorite":620},595,"建筑结构与设备",{"id":627,"name":628,"category":7,"favorite":620},715,"招标采购专业知识与法律法规",{"id":630,"name":631,"category":7,"favorite":620},848,"市政方向-通用基础",{"id":633,"name":634,"category":7,"favorite":8},534,"BIM工程师",{"id":636,"name":634,"category":7,"favorite":8},535]