[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-568-16":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":628},{"id":5,"name":6,"category":7,"favorite":8},568,"专业知识（给排水）","建筑工程",0,16,50,1213,[13,35,47,60,73,86,99,111,123,136,149,161,173,184,196,209,221,233,246,258,268,280,292,303,315,327,340,352,364,375,387,399,411,424,436,448,460,472,484,496,508,520,532,544,556,568,580,592,604,616],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},879386,2,"多选题","下列关于冷却塔特性数的表达中，哪几项正确？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","是个无量纲数",true,{"key":24,"text":25,"correct":26},"B","与冷却水量有关，与通入空气量无关",false,{"key":28,"text":29,"correct":22},"C","与淋水填料有关，与冷却塔构造有关",{"key":31,"text":32,"correct":26},"D","对同一冷却塔，当其淋水填料和冷却水量增、减相同的比例时，其冷却塔特性数不变","AC","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":33,"analysis":34},879387,"下述上向流斜管沉淀池底部配水区不宜小于1.5m的原因中，哪几项是正确的？( )",[39,41,43,45],{"key":20,"text":40,"correct":22},"进入的水流流速减少，可减少对斜管下滑沉泥的干扰影响",{"key":24,"text":42,"correct":26},"有利于减少斜管内的轴向流速，增大斜管内沉淀时间，提高悬浮物去除率",{"key":28,"text":44,"correct":22},"进入的水流流速减小，配水区末端恢复水头减少，压力平衡，使上升水流均匀",{"key":31,"text":46,"correct":26},"不易受外界风吹、温度变化影响，不使悬浮颗粒带出池外",{"id":48,"libraryId":5,"type":15,"typeLabel":16,"stem":49,"options":50,"answer":59,"analysis":34},879388,"下列关于各种形式地下水取水构筑物进水部分的描述中，哪些是正确的？( )",[51,53,55,57],{"key":20,"text":52,"correct":22},"完整式和非完整式管井都只通过过滤器进水",{"key":24,"text":54,"correct":26},"非完整式管井的进水部分包括其过滤器和井底的反滤层",{"key":28,"text":56,"correct":26},"完整式大口井的进水部分包括井壁进水孔和井底反滤层",{"key":31,"text":58,"correct":22},"渗渠的进水部分可以是穿孔管，也可以是带缝隙的暗渠","AD",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":72,"analysis":34},879389,"向设置网后水塔的配水管网供水的二级泵房，具有下列哪几项特点？( )",[64,66,68,70],{"key":20,"text":65,"correct":26},"供水量最高时，二级泵房扬程较高",{"key":24,"text":67,"correct":22},"晚间低峰(转输)时，二级泵房扬程较高",{"key":28,"text":69,"correct":22},"供水量最高时，二级泵房扬程较低",{"key":31,"text":71,"correct":26},"晚间低峰(转输)时，二级泵房扬程较低","BC",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":85,"analysis":34},879390,"冷却塔冷却数N与下列哪几项因素有关？( )",[77,79,81,83],{"key":20,"text":78,"correct":22},"水冷却前后的水温",{"key":24,"text":80,"correct":22},"冷却水量与风量",{"key":28,"text":82,"correct":26},"填料特性",{"key":31,"text":84,"correct":22},"气象条件","ABD",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":98,"analysis":34},879391,"以下几类城市给水管道中，哪几项不需要做内衬水泥砂浆防腐处理？( )",[90,92,94,96],{"key":20,"text":91,"correct":26},"无缝钢管",{"key":24,"text":93,"correct":22},"球墨铸铁管",{"key":28,"text":95,"correct":22},"自应力钢筋混凝土管",{"key":31,"text":97,"correct":22},"预应力钢筋混凝土管","BCD",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":59,"analysis":34},879392,"在湿式冷却塔理论计算的各项参数中，下列对湿球温度的理解，哪几项错误？( )",[103,105,107,109],{"key":20,"text":104,"correct":22},"如果冷却塔进水温度不变，湿球温度越低，进、出水温度差越小",{"key":24,"text":106,"correct":26},"当水温与空气的湿球温度相同且低于空气湿度时，水温停止下降",{"key":28,"text":108,"correct":26},"冷却塔出水温度只能在理论上接近湿球温度",{"key":31,"text":110,"correct":22},"冷却塔设计所采用的湿球温度值，应选取t年中整个夏季3个月的平均值",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":72,"analysis":34},879393,"在循环冷却水系统改造工程中，仅对机械通风逆流式冷却塔填料进行更换，若更换前后的填料类型不同，下列哪几项冷却工艺参数会发生变化？( )",[115,117,119,121],{"key":20,"text":116,"correct":26},"淋水密度",{"key":24,"text":118,"correct":22},"汽水比",{"key":28,"text":120,"correct":22},"冷却塔特性数N′",{"key":31,"text":122,"correct":26},"冷却数N",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":135,"analysis":34},879394,"一座滤池分为多格，采用等水头变速过滤，以下有关变速过滤工艺特点的叙述中，哪几项正确？( )",[127,129,131,133],{"key":20,"text":128,"correct":26},"过滤时的滤速指的是水流经过滤料缝隙中的滤速",{"key":24,"text":130,"correct":26},"多格滤池过滤时，每格进水流量相同",{"key":28,"text":132,"correct":22},"多格滤池过滤时，每格水头损失相同",{"key":31,"text":134,"correct":22},"一格冲洗时，其他几格滤池水头损失增加相同","CD",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":148,"analysis":34},879395,"下列有关过滤时杂质在滤层中分布和滤料选择的叙述中，哪几项正确？( )",[140,142,144,146],{"key":20,"text":141,"correct":22},"在设计滤速范围内，较大粒径滤料层中污泥容易分布到下层",{"key":24,"text":143,"correct":22},"双层滤料之间的密度差越大，越不容易混杂，冲洗效果越好",{"key":28,"text":145,"correct":26},"双层滤料之间的粒径度差越大，越不容易混杂，冲洗效果越好",{"key":31,"text":147,"correct":26},"附着污泥的滤料层再截留的杂质容易分布在上层","AB",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":33,"analysis":34},879396,"混凝剂投入水中后须迅速混合，不同的混合方法具有不同的特点，下列混合特点的叙述中，哪些是正确的？( )",[153,155,157,159],{"key":20,"text":154,"correct":22},"水泵混合迅速均匀，不必另行增加能源",{"key":24,"text":156,"correct":26},"管式静态混合是管道阻流部件扰动水体发生湍流的混合，不耗用能量",{"key":28,"text":158,"correct":22},"机械搅拌混合迅速均匀，需要另行增加设备，耗用能量",{"key":31,"text":160,"correct":26},"水力混合池利用水流跌落或改变水流速度、方向产生湍流混合，不耗用能量",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":85,"analysis":34},879397,"对采用常规处理工艺的自来水厂的排泥水处理系统，下列有关其排水池和排泥池的设计表述中，哪几项正确？( )",[165,167,169,171],{"key":20,"text":166,"correct":22},"排泥池和排水池分别接纳、调节沉淀池排泥水和滤池反冲洗废水",{"key":24,"text":168,"correct":22},"无论在厂内、外处理，当废水回收且处理规模较大时，排水池和排泥池均宜分建",{"key":28,"text":170,"correct":26},"综合排泥池均质和均量的主要对象为沉淀池的排泥水",{"key":31,"text":172,"correct":22},"排水池和排泥池的个数或分格数均不宜少于可单独运行的2个",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":175,"answer":33,"analysis":34},879398,[176,178,180,182],{"key":20,"text":177,"correct":22},"非碳酸盐硬度为5.10mmol\u002FL",{"key":24,"text":179,"correct":26},"重碳酸镁含量0mmol\u002FL",{"key":28,"text":181,"correct":22},"总硬度为2.50mmol\u002FL",{"key":31,"text":183,"correct":26},"总碱度为2.50mmol\u002FL",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":33,"analysis":34},879399,"虹吸滤池具有下列哪几项特点？( )",[188,190,192,194],{"key":20,"text":189,"correct":22},"采用小阻力配水系统",{"key":24,"text":191,"correct":26},"采用大阻力配水系统",{"key":28,"text":193,"correct":22},"等速过滤方式运行",{"key":31,"text":195,"correct":26},"减速过滤方式运行",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":208,"analysis":34},879400,"一座平流式沉淀池沉淀面积为 A，水深为 H，如果在H\u002F2处再加设一道平板，从沉淀理论上分析得出的如下判断中，哪几项是正确的？( )",[200,202,204,206],{"key":20,"text":201,"correct":22},"当进水流量不变时，沉淀池表面负荷一定是原来的1\u002F2",{"key":24,"text":203,"correct":26},"当进水流量不变时，对悬浮物的总去除率一定是原来的2倍",{"key":28,"text":205,"correct":22},"当对悬浮物的总去除率不变时，进水流量可增加一倍",{"key":31,"text":207,"correct":22},"当进水流量和对悬浮物的总去除率不变时，沉淀池的长度或宽度可减少一半","ACD",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":208,"analysis":34},879401,"以下关于给水处理中絮凝过程的论述，错误的是哪几项？( )",[213,215,217,219],{"key":20,"text":214,"correct":22},"絮凝过程颗粒逐步增大，为达到有效碰撞，搅拌强度应逐步增大",{"key":24,"text":216,"correct":26},"完善的絮凝不仅与搅拌强度有关，还与絮凝时间有关",{"key":28,"text":218,"correct":22},"由于水体流动促使颗粒相互碰撞絮凝称为“异向絮凝”",{"key":31,"text":220,"correct":22},"用于衡量异向絮凝强度的指标为速度梯度",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":33,"analysis":34},879402,"下列有关滤池滤料性能的叙述中，哪几项正确？( )",[225,227,229,231],{"key":20,"text":226,"correct":22},"单层石英砂滤料层中，总是粒径尺寸小的滤砂分布在上层，截流的杂质较多",{"key":24,"text":228,"correct":26},"多层滤料滤池的滤料层中，总是石英砂滤料分布在最下层，截流杂质较少",{"key":28,"text":230,"correct":22},"在过滤过程中，滤料层中的杂质穿透深度越大，滤料层含污量越大",{"key":31,"text":232,"correct":26},"滤料层反冲洗时较大的冲洗强度可把大粒径滤料冲到表面，发挥反粒度过滤效应",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":245,"analysis":34},879403,"下列关于冷却塔热力计算的规定和表述中，正确的有哪几项？( )",[237,239,241,243],{"key":20,"text":238,"correct":26},"冷却塔热力计算的设计任务就是冷却塔面积计算",{"key":24,"text":240,"correct":22},"冷却塔的热力计算宜采用焓差法或经验方法",{"key":28,"text":242,"correct":26},"计算冷却塔的最高冷却水温的气象资料，应采用近期连续不少于5年，每年最热时期3个月的月平均值。",{"key":31,"text":244,"correct":22},"计算冷却塔的各月的月平均冷却水温时，应采用近期连续不少于5年的相应各月的月平均气象条件","BD",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":85,"analysis":34},879404,"下列关于工业循环冷却水处理设计的叙述中，哪几项错误？( )",[250,252,254,256],{"key":20,"text":251,"correct":22},"流量较小的循环冷却水可作直流水使用",{"key":24,"text":253,"correct":22},"循环冷却水系统均应设置旁流水处理设施",{"key":28,"text":255,"correct":26},"再生水作为补充水时，循环冷却水的浓缩倍数不应低于2.5",{"key":31,"text":257,"correct":22},"补充水水质应以逐年水质分析数据的平均值作为设计和校核设备能力的依据",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":260,"answer":33,"analysis":34},879405,[261,263,264,266],{"key":20,"text":262,"correct":22},"经过一定接触时间后水中余氯为有效自由性氯",{"key":24,"text":34,"correct":26},{"key":28,"text":265,"correct":22},"采用化合氯消毒，与水接触2小时后出厂水中自由氯总量应不低于0.5mg\u002FL",{"key":31,"text":267,"correct":26},"在折点加氯消毒法中，发生在折点以前的水中余氯均为化合性氯",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":98,"analysis":34},879406,"当水的pH值大于5.5时，自然氧化法除铁，pH值对二价铁氧化速度的影响，以下哪几项说法正确？( )",[272,274,276,278],{"key":20,"text":273,"correct":26},"水的pH值降低，二价铁的氧化速度加快",{"key":24,"text":275,"correct":22},"水的pH值在碱性范围内比在酸性范围内，二价铁的氧化速度快",{"key":28,"text":277,"correct":22},"水的pH值每提高1个单位，二价铁的氧化速度增大100倍",{"key":31,"text":279,"correct":22},"脱除水中二氧化碳，可以提高二价铁的氧化速度",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":148,"analysis":34},879407,"采用活性炭深度处理饮用水时，有关影响活性炭吸附的下列表述中，哪些项是不正确的？( )",[284,286,288,290],{"key":20,"text":285,"correct":22},"对水中具有较强极性的吸附质，活性炭对其的吸附性能较强",{"key":24,"text":287,"correct":22},"在依靠生物作用降解有机物的生物活性炭处理阶段，活性炭不再具有吸附性能",{"key":28,"text":289,"correct":26},"易被活性炭吸附的水中吸附质，其分子量有一定的适宜范围",{"key":31,"text":291,"correct":26},"活性炭对三氯甲烷具有吸附作用",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":245,"analysis":34},879408,"下列有关自来水厂投加液氯消毒的表述中，哪几项不正确？( )",[296,298,300,301],{"key":20,"text":297,"correct":26},"相对来说，水的浊度越低，消毒的效果越好",{"key":24,"text":299,"correct":22},"水的pH值越高，消毒能力越强",{"key":28,"text":34,"correct":26},{"key":31,"text":302,"correct":22},"CT值中的C是消毒剂浓度(mg\u002FL)，指的是液氯投加量和处理水量的比值",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":148,"analysis":34},879409,"下列对过滤时截留水中悬浮颗粒原理的叙述中，哪几项正确？( )",[307,309,311,313],{"key":20,"text":308,"correct":22},"石英砂滤料表层形成泥膜后具有筛滤、拦截作用",{"key":24,"text":310,"correct":22},"石英砂滤料深层中的泥膜对细小颗粒具有筛滤、拦截作用",{"key":28,"text":312,"correct":26},"石英砂滤料层中的泥膜对细小颗粒具有黏附作用",{"key":31,"text":314,"correct":26},"不经混凝的胶体颗粒不具有相互黏附性能，不能用任何过滤方法去除",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":33,"analysis":34},879410,"以下关于冷却构筑物类型的叙述中，不正确的是哪几项？( )",[319,321,323,325],{"key":20,"text":320,"correct":22},"冷却构筑物可分为敞开式，密闭式和混合式三类",{"key":24,"text":322,"correct":26},"水面冷却物可分为水面面积有限的水体和水面面积很大的水体两类",{"key":28,"text":324,"correct":22},"混合通风横流式冷却塔可分为点滴式，薄膜式和点滴薄膜式三类",{"key":31,"text":326,"correct":26},"喷水冷却池与喷流式冷却塔都属于自然通风的冷却构筑物",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":339,"analysis":34},879411,"组成一个敞开式循环冷却水系统必不可少的设备有哪些？( )",[331,333,335,337],{"key":20,"text":332,"correct":22},"水泵",{"key":24,"text":334,"correct":22},"冷却构筑物",{"key":28,"text":336,"correct":22},"冷却水用水设备",{"key":31,"text":338,"correct":22},"水质稳定处理设备","ABCD",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":98,"analysis":34},879412,"膜分离法脱盐通常采用反渗透膜、纳滤膜和离子交换膜，这三种膜的驱动力有所不同，下列的各种说法，哪几项正确？( )",[344,346,348,350],{"key":20,"text":345,"correct":26},"离子交换膜脱盐的驱动力是浓度差",{"key":24,"text":347,"correct":22},"纳滤膜脱盐的驱动力是压力差",{"key":28,"text":349,"correct":22},"反渗透膜脱盐的驱动力是压力差",{"key":31,"text":351,"correct":22},"离子交换膜脱盐的驱动力是的电位差",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":72,"analysis":34},879413,"关于采用电子水处理器、静电水处理器和内磁水处理器对循环冷却水进行处理的叙述中，正确的是下列哪几项？( )",[356,358,360,362],{"key":20,"text":357,"correct":26},"电子、静电、内磁水处理器分别利用高压、低压静电场及磁场进行水处理",{"key":24,"text":359,"correct":22},"均具有除垢、杀菌及灭藻功用，但处理效果不如化学药剂法明显、稳定",{"key":28,"text":361,"correct":22},"均适合在小水量、水质以结垢型为主、浓缩倍数小的条件下采用",{"key":31,"text":363,"correct":26},"主要适用于结垢成分是硅酸盐型水，结垢成分是碳酸盐时不宜使用",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":245,"analysis":34},879414,"下列哪几项水质指标不代表具体成分，但能反映水质的某方面的特征？( )",[368,370,371,373],{"key":20,"text":369,"correct":26},"溶解氧",{"key":24,"text":34,"correct":22},{"key":28,"text":372,"correct":26},"氯化物",{"key":31,"text":374,"correct":22},"碱度",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":98,"analysis":34},879415,"供水管道沿程水头损失的计算，管道不同，采用的计算公式也不同，一般而言，下述说法哪几项正确？( )",[379,381,383,385],{"key":20,"text":380,"correct":26},"钢管、铸铁管沿程水头损失的计算不宜使用海曾一威廉公式",{"key":24,"text":382,"correct":22},"混凝土管(渠)及水泥砂浆内衬的金属管道，沿程水头损失宜采用舍齐公式计算",{"key":28,"text":384,"correct":22},"塑料管道的沿程水头损失计算宜采用维斯巴赫一达西公式计算",{"key":31,"text":386,"correct":22},"配水管网水力平差的水头损失计算宜使用海曾一威廉公式",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":59,"analysis":34},879416,"针对微污染水源，越来越多的自来水厂采用臭氧活性炭深度处理工艺，关于臭氧活性炭深度处理工艺，下列哪几项说法正确？( )",[391,393,395,397],{"key":20,"text":392,"correct":22},"当原水溴化物含量高时，臭氧—活性炭工艺出水中的溴酸盐浓度有超标风险",{"key":24,"text":394,"correct":26},"臭氧—活性炭工艺可以提高出厂水的生物安全性",{"key":28,"text":396,"correct":26},"臭氧—活性炭工艺不能去除水中的臭味",{"key":31,"text":398,"correct":22},"臭氧—活性炭工艺出水的耗氧量较常规处理工艺低",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":85,"analysis":34},879417,"经勘查，某地区地下水含水层厚度4.80m，底板埋藏深度12m，含水层透水性良好，适宜采用下列哪几项地下水取水构筑物？( )",[403,405,407,409],{"key":20,"text":404,"correct":22},"管井",{"key":24,"text":406,"correct":22},"完整式大口井",{"key":28,"text":408,"correct":26},"非完整式大口井",{"key":31,"text":410,"correct":22},"集水井井底封闭的辐射井",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":423,"analysis":34},879418,"在确定城镇给水系统时，以下叙述中哪几项是错误的？( )",[415,417,419,421],{"key":20,"text":416,"correct":22},"当水源地与供水区域有地形高差可利用时，必须采用重力输配水系统",{"key":24,"text":418,"correct":22},"多水源供水的给水系统，无论何时都应保持各水源的给水系统相互独立运行",{"key":28,"text":420,"correct":22},"当供水水质不能满足生活饮用水卫生标准时，可对饮水部分采用直饮水分质供水系统",{"key":31,"text":422,"correct":26},"城镇统一供水管网不得与自备水源供水系统直接连接","ABC",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":59,"analysis":34},879419,"以下哪些因素不影响地下水取水构筑物形式的选择？( )",[428,430,432,434],{"key":20,"text":429,"correct":22},"地下水矿化度大小",{"key":24,"text":431,"correct":26},"地下水埋藏深度",{"key":28,"text":433,"correct":26},"含水层岩性",{"key":31,"text":435,"correct":22},"距主要用水区距离",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":85,"analysis":34},879420,"关于平流式沉淀池穿孔墙的设计，下列哪几项正确？( )",[440,442,444,446],{"key":20,"text":441,"correct":22},"穿孔墙孔流速选择应考虑穿孔墙布水的均匀性",{"key":24,"text":443,"correct":22},"穿孔墙孔流速选择应考虑对絮凝体破碎的影响",{"key":28,"text":445,"correct":26},"穿孔墙孔应在池水面以下和池底板0.10m以上区域进行均匀和等孔布置",{"key":31,"text":447,"correct":22},"穿孔墙最上排孔宜在池内水位以下",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":148,"analysis":34},879421,"以下关于分区供水的叙述中，哪几项正确？( )",[452,454,456,458],{"key":20,"text":453,"correct":22},"山区城市的供水方向地形上升显著，宜采用串联供水",{"key":24,"text":455,"correct":22},"由同一泵站供水的分区供水为并联供水",{"key":28,"text":457,"correct":26},"采用分区供水一定可以降低给水系统造价",{"key":31,"text":459,"correct":26},"对于重力流供水的城市，不能采用分区供水",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":208,"analysis":34},879422,"某新规划建设的县级市，市政给水管网服务区内未设置水量调节构筑物。则下列哪几项有关该县级市给水管网设计的表述不准确？( )",[464,466,468,470],{"key":20,"text":465,"correct":22},"因城市较小，管网宜设计成枝状网",{"key":24,"text":467,"correct":26},"为节约投资，生活用水和消防用水共用同一管网",{"key":28,"text":469,"correct":22},"该市管网设计成环状时，应按消防时、最大转输时和最不利管段事故时三种工况进行校核",{"key":31,"text":471,"correct":22},"由于连接管网控制点的管网末梢管段流量较小，为提高流速，保证水质，该处管道管径从100mm改为更小的管径",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":245,"analysis":34},879423,"下列关于单层细砂滤料滤池单水冲洗使滤料处于流化态后，再增加冲洗强度的分析中，哪几项是正确的？( )",[476,478,480,482],{"key":20,"text":477,"correct":26},"冲洗水头损失增加，滤层膨胀率增大",{"key":24,"text":479,"correct":22},"冲洗水头损失不变，滤层膨胀率增大",{"key":28,"text":481,"correct":26},"冲洗水头损失增加，滤料摩擦作用增大",{"key":31,"text":483,"correct":22},"冲洗水头损失不变，滤料摩擦作用减弱",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":59,"analysis":34},879424,"在冷却水循环过程中，系统补充水和循环水含盐量比例确定后，蒸发、风吹、排污损失水量之间存在如下关系，哪几项正确？( )",[488,490,492,494],{"key":20,"text":489,"correct":22},"蒸发散失水量越多，需要排放污水水量越多",{"key":24,"text":491,"correct":26},"蒸发散失水量越多，需要排放污水水量越少",{"key":28,"text":493,"correct":26},"风吹散失水量越多，需要排放污水水量越多",{"key":31,"text":495,"correct":22},"风吹散失水量越多，需要排放污水水量减少",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":245,"analysis":34},879425,"下列关于全日制运行的给水系统各构筑物设计流量大小的叙述中，哪几项正确？( )",[500,502,504,506],{"key":20,"text":501,"correct":26},"水厂所有构筑物中，二级泵站的设计流量总是最大",{"key":24,"text":503,"correct":22},"地表水取水构筑物的设计流量总比水厂内水处理构筑物的设计流量大",{"key":28,"text":505,"correct":26},"地表水给水系统中原水输水管道的设计流量总比清水输水管道的设计流量小",{"key":31,"text":507,"correct":22},"采用管井取水给水系统中，原水总输水管道的设计流量比各个管井的设计取水量之和小",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":85,"analysis":34},879426,"不同的混凝剂(电解质)投加到水中发生混凝作用时，会出现哪些现象？( )",[512,514,516,518],{"key":20,"text":513,"correct":22},"分子量不同的两种电解质同时投入到水中，分子量大的先被吸附在胶体颗粒表面",{"key":24,"text":515,"correct":22},"吸附在胶体颗粒表面分子量小的电解质会被分子量大的电解质置换出来",{"key":28,"text":517,"correct":26},"吸附在胶体颗粒表面分子量大的电解质会被多个分子量小的电解质置换出来",{"key":31,"text":519,"correct":22},"投加较多的电解质时，胶体颗粒表面的ζ电位可能反逆",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":135,"analysis":34},879427,"下列关于大口井设计要求的叙述中，哪几项是正确的？( )",[524,526,528,530],{"key":20,"text":525,"correct":26},"大口井的深度不宜超过10m，直径不宜大于15m",{"key":24,"text":527,"correct":26},"大口井都要采用井底进水方式",{"key":28,"text":529,"correct":22},"井口周围应设宽度1.5m不透水的散水坡",{"key":31,"text":531,"correct":22},"井底进水宜铺设锅底形反滤层，反滤层滤料的粒径自下而上逐渐增大",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":85,"analysis":34},879428,"下列关于生活饮用水地表水源卫生防护的叙述中，哪几项正确？( )",[536,538,540,542],{"key":20,"text":537,"correct":22},"一级保护区的水质适用国家《地面水环境质量标准》Ⅱ类标准",{"key":24,"text":539,"correct":22},"二级保护区的水质适用国家《地面水环境质量标准》Ⅲ类标准",{"key":28,"text":541,"correct":26},"取水点上游1000m至下游100m水域内严格控制污染物排放量",{"key":31,"text":543,"correct":22},"取水点周围半径100m水域内，严禁从事可能污染水源的任何活动",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":423,"analysis":34},879429,"以下关于输配水管线布置原则的叙述中哪几项是错误的？( )",[548,550,552,554],{"key":20,"text":549,"correct":22},"为确保安全，当水源地有安全贮水池时，输水管可采用一根",{"key":24,"text":551,"correct":22},"生活饮用水管道严禁在毒物污染及腐蚀性地段穿越",{"key":28,"text":553,"correct":22},"原水输送必须采用管道或暗渠(隧洞)，不得采用明渠",{"key":31,"text":555,"correct":26},"允许间断供水的配水管网可采用枝状，但应考虑今后连成环状的可能",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":59,"analysis":34},879430,"输水干管不宜少于两条，并应加设连通管，不过，有时可修建一条输水管，下列哪几项正确？( )",[560,562,564,566],{"key":20,"text":561,"correct":22},"当设有安全贮水池时，安全贮水池之前，可修建一条输水管",{"key":24,"text":563,"correct":26},"当输水管道距离较长，建两条输水管道投资较大时，也可修建一条输水管",{"key":28,"text":565,"correct":26},"当设有安全贮水池时，安全贮水池的前、后均可修建一条输水管",{"key":31,"text":567,"correct":22},"当采用多水源供水时，可修建一条输水管",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":135,"analysis":34},879431,"当管网中无集中用水量时，节点流量和沿线流量的关系可以表述为下列哪几项？( )",[572,574,576,578],{"key":20,"text":573,"correct":26},"某管段起点和终点节点流量之和等于该管段的沿线流量",{"key":24,"text":575,"correct":26},"某点的节点流量的数值等于与该点相连所有管段沿线流量的总和",{"key":28,"text":577,"correct":22},"管网内所有节点流量的总和与所有沿线流量的总和相等",{"key":31,"text":579,"correct":22},"某点的节点流量的数值等于与该点相连所有管段沿线流量总和的一半",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":33,"analysis":34},879432,"下列地下水取水构筑物适用条件的叙述中，哪几项是错误的？( )",[584,586,588,590],{"key":20,"text":585,"correct":22},"渗渠只适用于取河床渗透水",{"key":24,"text":587,"correct":26},"管井既适用于取承压或无压含水层的水，也适用于取潜水",{"key":28,"text":589,"correct":22},"大口井只适用于取潜水和无压含水层的水",{"key":31,"text":591,"correct":26},"大口井既适用于取潜水，也适用于取承压或无压含水层的水",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":72,"analysis":34},879433,"下列关于冷却塔工艺构造设计说明中，正确的是哪几项？( )",[596,598,600,602],{"key":20,"text":597,"correct":26},"机械通风冷却塔设有配水系统和通风空气分配系统，而自然通风冷却塔不设通风空气分配系统",{"key":24,"text":599,"correct":22},"当冷却水中悬浮物含量大于50mg\u002FL且含有泥沙，应首先考虑选用槽式配水系统",{"key":28,"text":601,"correct":22},"无论何种冷却塔，都是进风口越大，冷却效果越好",{"key":31,"text":603,"correct":26},"冷却塔除水器通常安装在填料区之下集水池之上的进风口处",{"id":605,"libraryId":5,"type":15,"typeLabel":16,"stem":606,"options":607,"answer":72,"analysis":34},879434,"为保证普通快滤池反冲洗过程中配水均匀，在设计冲洗系统时正确的措施是下列哪几项？( )",[608,610,612,614],{"key":20,"text":609,"correct":26},"采用水塔供水反冲洗时，应尽量降低冲洗水塔的设计高度",{"key":24,"text":611,"correct":22},"采用高位水箱供水反冲洗时，应尽量降低冲洗水箱的设计水深",{"key":28,"text":613,"correct":22},"采用大流量水泵直接反冲洗时，应尽量减小吸水池水位变化",{"key":31,"text":615,"correct":26},"采用水泵直接反冲洗时，应尽量降低冲洗水泵安装高度",{"id":617,"libraryId":5,"type":15,"typeLabel":16,"stem":618,"options":619,"answer":245,"analysis":34},879435,"在冲洗水量满足要求的前提下，下述哪些因素影响滤池反冲洗过程水量的均匀性？( )",[620,622,624,626],{"key":20,"text":621,"correct":26},"采用水泵冲洗时，吸水井设置的高低",{"key":24,"text":623,"correct":22},"采用水泵冲洗时，吸水井水位变化幅度大小",{"key":28,"text":625,"correct":26},"采用高位水箱冲洗时，冲洗水箱容积的大小",{"key":31,"text":627,"correct":22},"采用高位水箱冲洗时，冲洗水箱水深的大小",[629,633,636,639,642,645],{"id":630,"name":631,"category":7,"favorite":632},1,"领导干部任职前廉政法规知识测试题",92,{"id":634,"name":635,"category":7,"favorite":630},595,"建筑结构与设备",{"id":637,"name":638,"category":7,"favorite":630},715,"招标采购专业知识与法律法规",{"id":640,"name":641,"category":7,"favorite":630},848,"市政方向-通用基础",{"id":643,"name":644,"category":7,"favorite":8},534,"BIM工程师",{"id":646,"name":644,"category":7,"favorite":8},535]