[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-568-15":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":620},{"id":5,"name":6,"category":7,"favorite":8},568,"专业知识（给排水）","建筑工程",0,15,50,1213,[13,35,48,60,73,86,99,112,125,135,147,159,171,183,195,208,219,231,243,255,267,280,292,300,310,322,334,346,358,370,382,394,405,417,428,440,452,464,476,488,500,512,524,536,548,560,572,584,596,608],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},879336,2,"多选题","下列关于冷却塔内空气焓的概念叙述中，不正确的是哪几项？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","温度为0℃的空气的焓等于湿空气含热量和所含水汽的汽化热量之和",false,{"key":24,"text":25,"correct":26},"B","温度为0℃的空气的焓等于干空气含热量和所含水汽的汽化热量之和",true,{"key":28,"text":29,"correct":22},"C","排出冷却塔饱和空气的焓等于饱和的湿空气含热量和所含水汽的汽化热量之和",{"key":31,"text":32,"correct":26},"D","排出冷却塔饱和空气的焓等于干空气含热量和冷却水的含热量之和","BD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},879337,"某地形高差较大城市采用高低两区供水，且每区均设网后高位水池，高区供水泵从低区高位水池中取水，计算低区高位水池调节容积时，必须掌握以下哪些资料？( )",[39,41,43,45],{"key":20,"text":40,"correct":26},"最高日低区用水量变化曲线",{"key":24,"text":42,"correct":22},"最高日高区用水量变化曲线",{"key":28,"text":44,"correct":26},"最高日水厂二级泵站供水曲线",{"key":31,"text":46,"correct":26},"最高日高区供水泵站供水曲线","ACD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":33,"analysis":34},879338,"在湖泊、水库内设计取水构筑物，下列叙述中哪些是正确的？( )",[52,54,56,58],{"key":20,"text":53,"correct":22},"由于水体是静止的，因此可不考虑泥砂影响的问题",{"key":24,"text":55,"correct":26},"在湖泊中取水口不要设置在夏季主风向向风面的凹岸处",{"key":28,"text":57,"correct":22},"由于水位变化幅度都较小，而风浪较大，因此不能采用移动式取水构筑物",{"key":31,"text":59,"correct":26},"在深水湖泊、水库中，宜考虑分层取水",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":72,"analysis":34},879339,"不能在给水管网中起到水量调节作用的是以下哪几项？( )",[64,66,68,70],{"key":20,"text":65,"correct":26},"增压泵站",{"key":24,"text":67,"correct":22},"高位水池",{"key":28,"text":69,"correct":26},"水厂清水池",{"key":31,"text":71,"correct":22},"调蓄泵站","AC",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":85,"analysis":34},879340,"为解决某城镇的生活给水管网供水量有时不能满足城镇用水量的要求，采取下列哪几项措施是可行的？( )",[77,79,81,83],{"key":20,"text":78,"correct":26},"从邻近有足够富余供水量的城镇生活给水管网接管引水",{"key":24,"text":80,"correct":26},"新建或扩建水厂",{"key":28,"text":82,"correct":22},"从本城镇有自备水源的某工厂的内部供水管网接管引水",{"key":31,"text":84,"correct":26},"要求本城的用水企业通过技术改造节约用水，减少用水量","ABD",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":98,"analysis":34},879341,"进行环状管网平差的基本原理是下列哪几项？( )",[90,92,94,96],{"key":20,"text":91,"correct":22},"确定节点流量",{"key":24,"text":93,"correct":22},"确定管段管径",{"key":28,"text":95,"correct":26},"满足节点连续方程",{"key":31,"text":97,"correct":26},"满足环网的连续方程","CD",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":111,"analysis":34},879342,"在计算城市配水管网的比流量时，应扣除的因素是哪几项？( )",[103,105,107,109],{"key":20,"text":104,"correct":26},"穿越无建筑物区的长度",{"key":24,"text":106,"correct":22},"穿越无居民居住的管线长度",{"key":28,"text":108,"correct":22},"无集中流量流出的管线长度",{"key":31,"text":110,"correct":26},"大用户的集中用水量","AD",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":124,"analysis":34},879343,"若城镇水厂取水构筑物采用虹吸管输水，试选出描述正确的几项。( )",[116,118,120,122],{"key":20,"text":117,"correct":26},"虹吸管设计流速不宜小于0.6m\u002Fs",{"key":24,"text":119,"correct":26},"当一条原水输水管停止工作时，其余管道的通过流量应不小于最高日平均时用水量与输水管漏损水量和水厂自用水量三项总和的70%",{"key":28,"text":121,"correct":26},"河面封冻时，取水头部进水孔上缘距冰层下缘不宜小于0.5m",{"key":31,"text":123,"correct":22},"虹吸管必须采用钢管","ABC",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":72,"analysis":34},879344,"以下关于敞开式循环冷却水系统的水质处理方法的叙述中，哪几项正确？( )",[129,130,131,133],{"key":20,"text":34,"correct":26},{"key":24,"text":34,"correct":22},{"key":28,"text":132,"correct":26},"为防止细菌、藻类繁殖产生代谢物形成黏性污垢，可投加氯气等氧化剂消毒杀菌",{"key":31,"text":134,"correct":22},"防止循环冷却水腐蚀的有效方法之一是输水管、换热器等采用非金属材质",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":124,"analysis":34},879345,"以下关于湿式冷却塔类型及构造的叙述中，不正确的是哪几项？( )",[139,141,143,145],{"key":20,"text":140,"correct":26},"湿式冷却塔构造中淋水填料是必不可少的",{"key":24,"text":142,"correct":26},"湿式冷却塔中只有喷流式冷却塔是无风孔的",{"key":28,"text":144,"correct":26},"湿式混合通风冷却塔按气水接触方向可分为逆流式和横流式两类",{"key":31,"text":146,"correct":22},"喷雾式冷却塔的主要缺点是对水质、水压要求高",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":85,"analysis":34},879346,"经过混凝、沉淀后进入滤池正向过滤时，水中悬浮物颗粒穿透滤层深度和下列哪些因素有关？( )",[151,153,155,157],{"key":20,"text":152,"correct":26},"滤料的粒径大小",{"key":24,"text":154,"correct":26},"过滤时的滤速大小",{"key":28,"text":156,"correct":22},"水的pH值高低",{"key":31,"text":158,"correct":26},"滤料层的厚度",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":170,"analysis":34},879347,"下列计算离心泵水泵安装高度的表述中，哪几项不正确？( )",[163,165,167,168],{"key":20,"text":164,"correct":26},"当水泵定型后，其允许的吸上真空高度为一固定值",{"key":24,"text":166,"correct":26},"水泵安装高度可等于水泵最大吸上真空高度",{"key":28,"text":34,"correct":22},{"key":31,"text":169,"correct":22},"水泵容许最大吸上真空高度修正所涉及的因素是当地的海拔高度和水温","AB",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":72,"analysis":34},879348,"下列关于石英砂滤料滤池冲洗原理叙述中，正确的是哪几项？( )",[175,177,179,181],{"key":20,"text":176,"correct":26},"高速水流冲洗时，上升水流把滤层托起，使滤料相互摩擦、滤料表层污泥脱落随水流排出池外",{"key":24,"text":178,"correct":22},"气、水冲洗时，上升的水流和空气一并作用把滤层托起，呈流态化状态，使之相互摩擦、滤料表层污泥脱落随水流排出池外",{"key":28,"text":180,"correct":26},"气、水同时冲洗时滤层摩擦效果比单水冲洗滤层膨胀摩擦效果好",{"key":31,"text":182,"correct":22},"滤池冲洗时滤层膨胀率越大，摩擦作用越大，滤料表层污泥越容易脱落",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":111,"analysis":34},879349,"下列关于在河流取水构筑物的表述，哪几项正确？( )",[187,189,191,193],{"key":20,"text":188,"correct":26},"取水构筑物处的水深一般要求不小于2.5m",{"key":24,"text":190,"correct":22},"取水构筑物应设置在桥梁前或桥梁后1km以外的地方",{"key":28,"text":192,"correct":22},"取水构筑物淹没进水孔上缘距设计最低水位深度最小取0.5m",{"key":31,"text":194,"correct":26},"取水构筑物顶面进水孔下缘距河床的高度不得小于1.0m",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":207,"analysis":34},879350,"某开式循环冷却水系统，冷却塔设在屋面上(底盘标高为+10m)，而设置的供水设施及用水设备均在地下一层(地坪标高为-5m)。用水设备的冷却水进口水压要求不低于0.25MPa，管道水头损失忽略不计。下列各系统流程中设置不当或不宜采用的有哪几项？( )",[199,201,203,205],{"key":20,"text":200,"correct":22},"冷却塔—集水池循环水泵—用水设备冷却塔",{"key":24,"text":202,"correct":26},"冷却塔循环水泵—用水设备冷却塔",{"key":28,"text":204,"correct":26},"冷却塔—用水设备—集水池循环水泵—冷却塔",{"key":31,"text":206,"correct":26},"冷却塔—用水设备循环水泵—冷却塔","BCD",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":210,"answer":98,"analysis":34},879351,[211,213,215,217],{"key":20,"text":212,"correct":22},"B点处压力满足要求",{"key":24,"text":214,"correct":22},"C点处压力满足要求",{"key":28,"text":216,"correct":26},"B点处压力不满足要求",{"key":31,"text":218,"correct":26},"C点处压力不满足要求",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":170,"analysis":34},879352,"在混凝过程中，为了提高混凝效果，有时需要投加助凝剂，下面有关助凝剂作用的叙述中，哪些是正确的？( )",[223,225,227,229],{"key":20,"text":224,"correct":26},"聚丙烯酰胺助凝剂既有助凝作用又有混凝作用",{"key":24,"text":226,"correct":26},"石灰、氢氧化钠主要促进混凝剂水解聚合，没有混凝作用",{"key":28,"text":228,"correct":22},"投加氯气破坏有机物干扰，既有助凝作用又有混凝作用",{"key":31,"text":230,"correct":22},"投加黏土提高颗粒碰撞速率，增加混凝剂水解产物凝结中心，既有助凝作用又有混凝作用",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":98,"analysis":34},879353,"当斜板沉淀池液面负荷一定时，斜板的设计尺寸与去除悬浮物的效率密切相关。在下列叙述中哪几项是正确的？( )",[235,237,239,241],{"key":20,"text":236,"correct":22},"斜板的间距越大，板间流速越小，去除悬浮物的效率越高",{"key":24,"text":238,"correct":22},"斜板的宽度越大，斜板投影面积越大，去除悬浮物的效率越高",{"key":28,"text":240,"correct":26},"斜板的长度越大，斜板投影面积越大，去除悬浮物的效率越高",{"key":31,"text":242,"correct":26},"斜板倾斜角度越小，斜板投影面积越大，去除悬浮物的效率越高",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":33,"analysis":34},879354,"有关给水输水管的表述，哪几项正确？( )",[247,249,251,253],{"key":20,"text":248,"correct":22},"从水源输水到水厂、从水厂输水到配水管网和从配水管网通过枝状管送水到用户的管道称为输水管",{"key":24,"text":250,"correct":26},"从水厂到管网的输水管应保证用户所需的水量和水压，并保证不间断供水",{"key":28,"text":252,"correct":22},"对设置有前置大型高位贮水池的管网，其从水厂到管网的输水管应按两根设置",{"key":31,"text":254,"correct":26},"对于长度小于1km且竖向布置平缓的输水管，其间可不设透气设施",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":170,"analysis":34},879355,"下列关于球形颗粒在静水中自由沉淀受力分析中，正确的是哪几项？( )",[259,261,263,265],{"key":20,"text":260,"correct":26},"单颗粒在静水中自由沉淀时，在水中的重力大小不变",{"key":24,"text":262,"correct":26},"单颗粒在静水中自由沉淀等速下沉时，受到的绕流阻力大小不变",{"key":28,"text":264,"correct":22},"球形颗粒在水中静止时，该颗粒在水中的重力等于沉淀绕流阻力",{"key":31,"text":266,"correct":22},"球形颗粒在水中等速上浮时，该颗粒在水中的重力小于沉淀绕流阻力",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":279,"analysis":34},879356,"关于水源的选择对城市给水系统布置的影响，下列叙述中哪几项是错误的？( )",[271,273,275,277],{"key":20,"text":272,"correct":22},"水源地的位置将影响到城市给水系统的供水方式",{"key":24,"text":274,"correct":26},"水源的类型将决定城市给水系统的供水水质目标",{"key":28,"text":276,"correct":26},"水源地的位置将影响到城市给水系统的设计规模",{"key":31,"text":278,"correct":22},"水源的类型将影响到城市给水系统的净水工艺","BC",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":111,"analysis":34},879357,"进行环状管网水力计算一般是在初步的管段流量分配、选定管径及其水头损失计算后再进行水力平差。其水力平差计算的原因包括下述哪几项？( )",[284,286,288,290],{"key":20,"text":285,"correct":26},"因初步计算结果尚不能满足能量方程",{"key":24,"text":287,"correct":22},"因初步计算结果尚不能满足连续性方程",{"key":28,"text":289,"correct":22},"因初步计算结果尚不符合经济管径要求",{"key":31,"text":291,"correct":26},"因初步计算结果尚不能满足各环闭合差规定要求",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":33,"analysis":34},879358,"自由性氯消毒时，低pH消毒效果好，主要原因是下列哪几项？( )",[296,297,298,299],{"key":20,"text":34,"correct":22},{"key":24,"text":34,"correct":26},{"key":28,"text":34,"correct":22},{"key":31,"text":34,"correct":26},{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":33,"analysis":34},879359,"下列有关采用接触催化氧化除铁法处理地下水的认识中，哪些是正确的？( )",[304,305,307,308],{"key":20,"text":34,"correct":22},{"key":24,"text":306,"correct":26},"曝气之后的原水可直接进入含有活性滤膜滤料的滤池",{"key":28,"text":34,"correct":22},{"key":31,"text":309,"correct":26},"锰砂滤料的活性滤膜成熟期较石英砂滤料短",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":33,"analysis":34},879360,"关于叶片式水泵的比转数，下列说法中，哪几项正确？( )",[314,316,318,320],{"key":20,"text":315,"correct":22},"是不同叶片式水泵转速之比的数值",{"key":24,"text":317,"correct":26},"反映叶片式水泵共性，作为水泵规格化的综合特征的数值",{"key":28,"text":319,"correct":22},"当水泵转速一定时，同样流量的水泵比转数越大，扬程越大",{"key":31,"text":321,"correct":26},"当水泵转速一定时，同样扬程的水泵比转数越大，流量越大",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":124,"analysis":34},879361,"以下哪几项因素与水泵标准状况不一致时，须对水泵的允许吸上真空高度进行修正？( )",[326,328,330,332],{"key":20,"text":327,"correct":26},"水中的泥沙含量增大",{"key":24,"text":329,"correct":26},"水的饱和蒸汽压力增大",{"key":28,"text":331,"correct":26},"安装地的海拔高度增大",{"key":31,"text":333,"correct":22},"水的硬度增大",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":85,"analysis":34},879362,"下列关于斗槽式取水构筑物位置设置和使用条件的叙述中，哪几项正确？( )",[338,340,342,344],{"key":20,"text":339,"correct":26},"斗槽式取水构筑物应设置在河流凹岸靠近主流的岸边处",{"key":24,"text":341,"correct":26},"顺流式斗槽取水构筑物适宜在含砂量大，冰凌情况不严重的河流取水",{"key":28,"text":343,"correct":22},"逆流式斗槽取水构筑物适用于含沙量大，冰凌情况严重的河流取水",{"key":31,"text":345,"correct":26},"双流式斗槽适用于在含砂量大，冰凌情况严重的河流取水",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":72,"analysis":34},879363,"以下关于在某河床中设置渗渠的叙述中，哪几项正确？( )",[350,352,354,356],{"key":20,"text":351,"correct":26},"渗渠由集水管、检查井、集水井、泵房及反滤层组成",{"key":24,"text":353,"correct":22},"检查井采用钢筋混凝土结构，井底应设流槽，使水源通畅",{"key":28,"text":355,"correct":26},"钢筋混凝土集水管内径800mm，管道坡度0.003，坡向集水井",{"key":31,"text":357,"correct":22},"集水管进水孔径为20mm，外设3层反滤层，滤料粒径外层80mm，最内层18mm",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":33,"analysis":34},879364,"当水源取水泵房、净水设施及二级泵房能力有富余而清水池调节容量不足，水厂又无空地扩建清水池时，为满足用水需要可采用下列哪几项措施？( )",[362,364,366,368],{"key":20,"text":363,"correct":22},"一级泵房水泵改为变频调速泵",{"key":24,"text":365,"correct":26},"在管网中增建调节构筑物",{"key":28,"text":367,"correct":22},"加大出厂配水管道能力",{"key":31,"text":369,"correct":26},"用水高峰时段增加取水泵房和净水设施流量",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":170,"analysis":34},879365,"为保证城市自来水管网水质，布置管网时采取以下技术措施，哪几项不正确？( )",[374,376,378,380],{"key":20,"text":375,"correct":26},"不宜与非生活饮用水管网连接",{"key":24,"text":377,"correct":26},"不宜与自备水源供水系统直接连接",{"key":28,"text":379,"correct":22},"尽量避免穿越毒物污染地区",{"key":31,"text":381,"correct":22},"尽量避免穿越管道腐蚀地区",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":279,"analysis":34},879366,"工程设计中，为便于管网计算，通常采用折算系数a=0.5将管段沿线流量折算为管段两端节点流量，但实际上该折算系数是一个近似值，下列叙述正确的是哪几项？( )",[386,388,390,392],{"key":20,"text":387,"correct":22},"靠近水厂出水管道的管段的折算系数大于0.5",{"key":24,"text":389,"correct":26},"靠近管网末端的管段的折算系数大于0.5",{"key":28,"text":391,"correct":26},"越靠近水厂出水管的管段的折算系数越接近于0.5",{"key":31,"text":393,"correct":22},"越靠近管网末端的管段的折算系数越接近于0.5",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":170,"analysis":34},879367,"当地下水中铁、锰含量超标时采用接触催化氧化法处理。在工艺设计中，下列哪几项的概念正确？( )",[398,399,401,403],{"key":20,"text":34,"correct":26},{"key":24,"text":400,"correct":26},"普通除锰滤池在长久运行后也会产生除锰菌",{"key":28,"text":402,"correct":22},"除铁、除锰各自独立进行，铁的存在对锰的去除没有影响",{"key":31,"text":404,"correct":22},"曝气装置的选定依据仅按充氧程度的要求确定即可",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":33,"analysis":34},879368,"下列关于循环冷却水水质处理的叙述中，哪几项正确？( )",[409,411,413,415],{"key":20,"text":410,"correct":22},"旁滤过滤器安装在循环水总管道上，对循环冷却水量进行全流量过滤",{"key":24,"text":412,"correct":26},"旁滤去除的主要是循环冷却水中的悬浮物含量",{"key":28,"text":414,"correct":22},"腐蚀、结垢和微生物控制，是循环冷却水处理的全部内容",{"key":31,"text":416,"correct":26},"通过酸化处理，将水中碳酸氢钙、碳酸氢镁转化为非碳酸钙、镁",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":419,"answer":170,"analysis":34},879369,[420,422,424,426],{"key":20,"text":421,"correct":26},"立式轴流泵",{"key":24,"text":423,"correct":26},"立式导叶式混流泵",{"key":28,"text":425,"correct":22},"卧式离心泵",{"key":31,"text":427,"correct":22},"卧式轴流泵",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":170,"analysis":34},879370,"下列有关虹吸滤池工艺特点的叙述中，哪几项是正确的？( )",[432,434,436,438],{"key":20,"text":433,"correct":26},"虹吸滤池过滤时，从进水渠分配到各格滤池的水量相同",{"key":24,"text":435,"correct":26},"一组虹吸滤池中，一格滤池冲洗时，该格滤池进水虹吸管中断进水",{"key":28,"text":437,"correct":22},"根据计算确定分为n格的虹吸滤池，建造时少于或多于n格，都不能正常工作",{"key":31,"text":439,"correct":22},"降低虹吸滤池排水渠向外排水的堰口标高，可以增大滤池的冲洗水头",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":47,"analysis":34},879371,"下列有关虹吸滤池和无阀滤池共同特点的叙述中，哪几项正确？( )",[444,446,448,450],{"key":20,"text":445,"correct":26},"在正常情况下，都是变水头过滤运行",{"key":24,"text":447,"correct":22},"都设有反冲洗一格滤池的冲洗水箱",{"key":28,"text":449,"correct":26},"均采用中阻力或小阻力的配水系统",{"key":31,"text":451,"correct":26},"均采用真空系统或继电控制虹吸进水和虹吸排水、实现无阀操作、自动化控制",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":33,"analysis":34},879372,"下列关于取水构(建)筑物的设计要求中，哪几项正确？( )",[456,458,460,462],{"key":20,"text":457,"correct":22},"建在防洪堤内的取水泵房进口地平设计标高为设计最高水位加0.5m",{"key":24,"text":459,"correct":26},"位于湖泊边的最底层进水孔下缘距湖底的高度不宜小于1.0m",{"key":28,"text":461,"correct":22},"位于水库中的侧面进水孔上缘在设计最低水位下的最小深度为0.3m",{"key":31,"text":463,"correct":26},"位于江河上的最底层顶面进水孔下缘河床的最小高度为1.0m",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":33,"analysis":34},879373,"在配水管网中设置高位水池具有以下哪几项优点？( )",[468,470,472,474],{"key":20,"text":469,"correct":22},"有利于供水区域扩大和管网延伸",{"key":24,"text":471,"correct":26},"可减少水厂清水池调节容积",{"key":28,"text":473,"correct":22},"可适应最小服务水头要求的改变",{"key":31,"text":475,"correct":26},"可减小水厂二级泵房设计流量",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":98,"analysis":34},879374,"在下列有关影响地表水取水构筑物设计主要因素的表述中，哪几项正确？( )",[480,482,484,486],{"key":20,"text":481,"correct":22},"取用江河水的构筑物，应以设计洪水重现期100年确定防洪标准",{"key":24,"text":483,"correct":22},"用地表水作为工业企业供水水源时，其设计枯水流量保证率应低于城市供水",{"key":28,"text":485,"correct":26},"江河取水设计枯水位保证率的上限高于设计枯水流量保证率上限的理由，主要是前者安全性要求更高",{"key":31,"text":487,"correct":26},"固定式地表水取水构筑物取水头部及泵组安装标高的决定因素是设计枯水位",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":279,"analysis":34},879375,"密度比水大的颗粒在静水中的自由沉淀，其沉速大小主要与下列哪些因素有关？( )",[492,494,496,498],{"key":20,"text":493,"correct":22},"颗粒表面电荷的高低",{"key":24,"text":495,"correct":26},"颗粒在水中的重量",{"key":28,"text":497,"correct":26},"颗粒的形状与粒径大小",{"key":31,"text":499,"correct":22},"颗粒在水中的体积浓度",{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":33,"analysis":34},879376,"下列关于反渗透和纳滤在水处理中的应用特点的叙述中，哪几项正确？( )",[504,506,508,510],{"key":20,"text":505,"correct":22},"反渗透和纳滤去除水中杂质的原理和石英砂滤池过滤完全相同",{"key":24,"text":507,"correct":26},"反渗透可无选择性地去除水中大部分离子，但不能制取高纯水",{"key":28,"text":509,"correct":22},"反渗透膜截留大分子杂质时水渗透压力低，截留小分子杂质时水渗透压压力高，所以反渗透用于自来水脱盐时采用中等的工作压力(1.4～4.2MPa)",{"key":31,"text":511,"correct":26},"纳滤对二价和三价离子的去除率较高，对一价离子去除率较低",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":170,"analysis":34},879377,"在一条通航的河道中建取水构筑物时，下述观点中不正确的是哪几项？( )",[516,518,520,522],{"key":20,"text":517,"correct":26},"在河道的弯曲段，取水构筑物应建在凸岸",{"key":24,"text":519,"correct":26},"为不影响船舶航行，应采用岸边式取水构筑物",{"key":28,"text":521,"correct":22},"应按航运部门的要求，在取水构筑物附近设置标志",{"key":31,"text":523,"correct":22},"在码头附近的取水构筑物，应设置防船舶撞击的设施",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":85,"analysis":34},879378,"下列关于河床演变的叙述中，哪几项错误？( )",[528,530,532,534],{"key":20,"text":529,"correct":26},"河床纵向变形和横向变形在一般情况下是各自独立进行的",{"key":24,"text":531,"correct":26},"凸岸淤积、凹岸冲刷，是由于河床的纵向变形造成的",{"key":28,"text":533,"correct":22},"河床在枯水期也会发生变化",{"key":31,"text":535,"correct":26},"影响河床演变最重要的是悬移质泥沙",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":47,"analysis":34},879379,"下列关于湿式逆流冷却塔的性能的描述中，哪几项正确？( )",[540,542,544,546],{"key":20,"text":541,"correct":26},"冷幅宽越小，说明其散热量越小",{"key":24,"text":543,"correct":22},"冷幅高越小，说明其冷却效果越差",{"key":28,"text":545,"correct":26},"特性数越小，说明其冷却能力越差",{"key":31,"text":547,"correct":26},"气水比越小，说明其冷却推动力越小",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":33,"analysis":34},879380,"有关给水工程的下述说法不正确的是哪几项？( )",[552,554,556,558],{"key":20,"text":553,"correct":22},"城市管网中的调蓄泵站相当于水塔的作用",{"key":24,"text":555,"correct":26},"水质良好的深井地下水可不经消毒处理，直接作为生活饮用水",{"key":28,"text":557,"correct":22},"给水工程应按远期规划、近远期结合、以近期为主的原则进行设计",{"key":31,"text":559,"correct":26},"《室外给水设计规范》GB50013-2006适用于新建的城镇及工业区临时性给水工程设计",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":47,"analysis":34},879381,"理想沉淀池必须符合下列哪几项规定？( )",[564,566,568,570],{"key":20,"text":565,"correct":26},"水流沿水平方向等速流动",{"key":24,"text":567,"correct":22},"颗粒间存在絮凝",{"key":28,"text":569,"correct":26},"颗粒沉到池底后不再返回水中",{"key":31,"text":571,"correct":26},"颗粒处于自由沉淀",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":72,"analysis":34},879382,"有关湖泊与水库取水构筑物的表述，下列哪几项不正确？( )",[576,578,580,582],{"key":20,"text":577,"correct":26},"水库取水构筑物的防洪标准应与城市防洪标准相同，并应采用设计和校核两级标准",{"key":24,"text":579,"correct":22},"取用湖泊水的取水构筑物，其吸水管应设置加氯设施",{"key":28,"text":581,"correct":26},"对于水深较大的湖泊和水库，应采取分层取水，主要原因在于可使取得的水的温度保持相对稳定",{"key":31,"text":583,"correct":22},"取水口应远离湖泊支流汇入处、并靠近水流出口",{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":111,"analysis":34},879383,"机械搅拌澄清池设计水力停留时间1.2～1.5h，清水区上升流速0.8～1.0mm\u002Fs，当叶轮提升流量是进水流量的3～5倍时，具有较好的澄清处理效果。下列叙述中哪几项是正确的？( )",[588,590,592,594],{"key":20,"text":589,"correct":26},"该澄清池充分利用了回流泥渣的絮凝作用，集混凝、泥水分离于一体",{"key":24,"text":591,"correct":22},"设计的回流泥渣流量是进水流量的3～5倍",{"key":28,"text":593,"correct":22},"随水流进入澄清池的泥渣停留时间是1.2～1.5h",{"key":31,"text":595,"correct":26},"清水区去除的最小颗粒沉速≥0.8～1.0mm\u002Fs",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":33,"analysis":34},879384,"在城市给水系统设计流量的确定和计算时，关于管网漏损水量计入与否，下述说法正确的是哪几项？( )",[600,602,604,606],{"key":20,"text":601,"correct":22},"二级泵站的设计流量，应另外计入管网漏损水量",{"key":24,"text":603,"correct":26},"一级泵站的设计流量，应另外计入原水输水管(渠)的漏损水量",{"key":28,"text":605,"correct":22},"从二级泵站向管网输水的管道的设计流量，应另外计入管网漏损水量",{"key":31,"text":607,"correct":26},"从一级泵站向净水厂输水的原水输水管(渠)的设计流量，应另外计入原水输水管(渠)的漏损水量",{"id":609,"libraryId":5,"type":15,"typeLabel":16,"stem":610,"options":611,"answer":207,"analysis":34},879385,"计算城镇供水量时，管网漏损水率取值应考虑的因素为下列哪几项？( )",[612,614,616,618],{"key":20,"text":613,"correct":22},"管网供水量大小",{"key":24,"text":615,"correct":26},"管网平均水压大小",{"key":28,"text":617,"correct":26},"管道材质及接口形式",{"key":31,"text":619,"correct":26},"单位管长供水量大小",[621,625,628,631,634,637],{"id":622,"name":623,"category":7,"favorite":624},1,"领导干部任职前廉政法规知识测试题",92,{"id":626,"name":627,"category":7,"favorite":622},595,"建筑结构与设备",{"id":629,"name":630,"category":7,"favorite":622},715,"招标采购专业知识与法律法规",{"id":632,"name":633,"category":7,"favorite":622},848,"市政方向-通用基础",{"id":635,"name":636,"category":7,"favorite":8},534,"BIM工程师",{"id":638,"name":636,"category":7,"favorite":8},535]