[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-568-10":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":605},{"id":5,"name":6,"category":7,"favorite":8},568,"专业知识（给排水）","建筑工程",0,10,50,1213,[13,34,46,58,70,81,93,105,117,129,137,149,161,173,185,197,209,221,233,245,257,269,281,293,305,317,329,336,348,359,370,382,393,405,414,426,438,450,462,474,486,498,510,522,534,546,558,570,581,593],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},879086,1,"单选题","下列关于建筑生活热水管网计算，哪项正确？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","热媒管路的自然循环压力大于第二循环管网的总水头损失时，可采用自然循环",false,{"key":24,"text":25,"correct":26},"B","热水管网的水头损失采用的计算公式与其冷水系统采用的计算公式相同",true,{"key":28,"text":29,"correct":22},"C","考虑热水结垢等因素，其允许流速应小于同径冷水管的允许流速",{"key":31,"text":32,"correct":22},"D","全日制建筑物内热水管道设计秒流量计算方法不同于冷水管道","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},879087,"下列何项不能作为划分自动喷水灭火系统设置场所火灾危险等级的依据？( )",[38,40,42,44],{"key":20,"text":39,"correct":22},"由可燃物的性质、数量及分布状况等确定的火灾荷载",{"key":24,"text":41,"correct":22},"由面积、高度及建筑物构造等情况体现的室内空间条件",{"key":28,"text":43,"correct":26},"由气温、日照及降水等气候因素反映的环境条件",{"key":31,"text":45,"correct":22},"由人员疏散难易、消防队增援等决定的外部条件",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},879088,"某高层建筑采用消防水池、消防泵、管网和高位水箱、稳压泵等组成消火栓给水系统。下列该系统消防泵自动控制的说明中，哪一项是正确的？( )",[50,52,54,56],{"key":20,"text":51,"correct":26},"由消防泵房内消防干管上设压力开关控制消防泵的启、停",{"key":24,"text":53,"correct":22},"由每个消火栓处设消防按钮装置直接启泵，并在消防控制中心设手动启、停消防泵装置",{"key":28,"text":55,"correct":22},"由稳压泵处消防管上的压力开关控制消防泵的启、停",{"key":31,"text":57,"correct":22},"由稳压泵处消防管上的压力开关控制消防泵的启、停，并在消防控制中心没手动启、停消防泵装置",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},879089,"游泳池运行过程中需要加热时，其设计耗热量应以下列哪项为计算依据？( )",[62,64,66,68],{"key":20,"text":63,"correct":22},"池水表面蒸发损失热量的1.2倍与补充新鲜水加热所需热量之和",{"key":24,"text":65,"correct":22},"池水初次加热时所需的热量",{"key":28,"text":67,"correct":22},"游泳池溢流水和过滤设备反冲洗时排水损失的热量",{"key":31,"text":69,"correct":26},"池水表面蒸发损失热量、补充新鲜水加热需热量、管道和池壁损失热量之和",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":72,"answer":20,"analysis":33},879090,[73,75,77,79],{"key":20,"text":74,"correct":26},"S1",{"key":24,"text":76,"correct":22},"S2",{"key":28,"text":78,"correct":22},"S3",{"key":31,"text":80,"correct":22},"S4",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":33},879091,"以下有关热水供应系统管材选择和附件设置的叙述中，哪项是正确的？( )",[85,87,89,91],{"key":20,"text":86,"correct":22},"设备机房内温度高，故不应采用塑料热水管",{"key":24,"text":88,"correct":26},"定时供应热水系统内水温冷热周期性变化大，故不宜选用塑料热水管",{"key":28,"text":90,"correct":22},"加热设备凝结水回水管上设有疏水器时，其旁应设旁通管，以利维修",{"key":31,"text":92,"correct":22},"外径小于或等于32mm的塑料管可直接埋在建筑垫层内",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":24,"analysis":33},879092,"计算居住小区室外给水管道设计流量时，下列哪种因素不必考虑？( )",[97,99,101,103],{"key":20,"text":98,"correct":22},"服务人数",{"key":24,"text":100,"correct":26},"小区内建筑物高度",{"key":28,"text":102,"correct":22},"用水定额",{"key":31,"text":104,"correct":22},"卫生器具设置标准",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":24,"analysis":33},879093,"下列建筑生活给水系统设计中，哪项措施不具有节水效果？( )",[109,111,113,115],{"key":20,"text":110,"correct":22},"控制配水点处的水压",{"key":24,"text":112,"correct":26},"设置备用加压供水泵",{"key":28,"text":114,"correct":22},"贮水池设置溢流信号管",{"key":31,"text":116,"correct":22},"控制用水点处冷、热水供水压差≤0.02MPa",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":20,"analysis":33},879094,"下列关于建筑给水管道上止回阀的选择和安装要求中，哪项是不正确的？( )",[121,123,125,127],{"key":20,"text":122,"correct":26},"在引入管设置倒流防止器前的管段上应设置止回阀",{"key":24,"text":124,"correct":22},"进、出水管合用一条管道的高位水箱，其出水管段上应设置止回阀",{"key":28,"text":126,"correct":22},"为削弱停泵水锤，在大口径水泵出水管上选用安装阻尼缓闭止回阀",{"key":31,"text":128,"correct":22},"水流方向自上而下的立管，不应安装止回阀",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":20,"analysis":33},879095,"某10层住宅(层高2.8m)的供水系统如图所示，低层利用市政管网直接供水，可利用的水压为0.22mpa，初步确定其中正确合理的给水系统是哪一项？( )",[133,134,135,136],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":28,"analysis":33},879096,"下列关于高层建筑给水系统竖向分区的叙述中，哪项正确？( )",[141,143,145,147],{"key":20,"text":142,"correct":22},"由于并联供水方式投资大，不宜用于超高层建筑中",{"key":24,"text":144,"correct":22},"由于减压供水方式能耗大，不应用于生活给水系统中",{"key":28,"text":146,"correct":26},"由于并联供水方式管道承压大，不宜用于超高层建筑中",{"key":31,"text":148,"correct":22},"由于串联供水方式的安全可靠性差，不宜用于超高层建筑中",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":24,"analysis":33},879097,"下列有关排水管材选择的叙述中，何项不符合规范要求？( )",[153,155,157,159],{"key":20,"text":154,"correct":22},"多层建筑重力流雨水排水系统宜采用建筑排水塑料管",{"key":24,"text":156,"correct":26},"设有中水处理站的居住小区排水管道应采用混凝土管",{"key":28,"text":158,"correct":22},"加热器的泄水管应采用金属管或耐热排水塑料管",{"key":31,"text":160,"correct":22},"建筑内排水管安装在环境温度可能低于0℃的场所时，应选用柔性接口机制排水铸铁管",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":24,"analysis":33},879098,"下列关于生活排水立管的表述，哪项正确？( )",[165,167,169,171],{"key":20,"text":166,"correct":22},"采用特殊单立管时其通水能力大于采用仅设伸顶通气管的立管",{"key":24,"text":168,"correct":26},"塑料管内壁光滑可加大其排水速度",{"key":28,"text":170,"correct":22},"塑料管的通水能力大于铸铁管",{"key":31,"text":172,"correct":22},"内壁光滑可加大排水能力",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":20,"analysis":33},879099,"下列哪项自动喷水灭火系统的设置场所可不设置火灾报警系统？( )",[177,179,181,183],{"key":20,"text":178,"correct":26},"设置湿式系统的场所",{"key":24,"text":180,"correct":22},"设置预作用系统的场所",{"key":28,"text":182,"correct":22},"设置雨淋系统的场所",{"key":31,"text":184,"correct":22},"设置自动控制水幕系统的场所",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":24,"analysis":33},879100,"下面关于给水管道布置的叙述中，何项是错误的？( )",[189,191,193,195],{"key":20,"text":190,"correct":22},"居住小区的室外给水管网宜布置成环状，室内生活给水管网宜布置成枝状",{"key":24,"text":192,"correct":26},"居住小区的室内外给水管网均宜布置成环状",{"key":28,"text":194,"correct":22},"给水管、热水管、排水管同沟敷设时，给水管应在热水管之下，排水管之上",{"key":31,"text":196,"correct":22},"同沟敷设的给水管、热水管、排水管之间净距宜≥0.3m",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":31,"analysis":33},879101,"室内消火栓的布置，哪种情况可采用1支消火栓的1股充实水柱到达同层室内任何部位？( )",[201,203,205,207],{"key":20,"text":202,"correct":22},"建筑高度≤24m的仓库",{"key":24,"text":204,"correct":22},"建筑高度≤24m，且建筑体积≤5000㎡的厂房",{"key":28,"text":206,"correct":22},"建筑高度≤54m的住宅",{"key":31,"text":208,"correct":26},"建筑高度≤54m，且每单元设置一部疏散楼梯的住宅",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":20,"analysis":33},879102,"下述关于高层建筑生活给水系统的竖向分区要求中，哪项是错误的？( )",[213,215,217,219],{"key":20,"text":214,"correct":26},"高层建筑生活给水系统竖向分区的配水管配水横管进口水压宜小于0.1MPa",{"key":24,"text":216,"correct":22},"生活给水系统竖向分区各区最低卫生器具配水点的静水压力，在特殊情况下不宜大于0.55MPa",{"key":28,"text":218,"correct":22},"生活给水系统不宜提倡以减压阀减压分区作为主要供水方式",{"key":31,"text":220,"correct":22},"竖向分区采取水泵直接串联供水方式，各级提升泵联锁，使用时先启动下一级泵，再启动上一级泵",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":31,"analysis":33},879103,"某饮料用水贮水箱的泄水由DN50泄水管经排水漏斗排入排水管，则排水漏斗与泄水管排水口间的最小空气间隙应为以下何项？( )",[225,227,229,231],{"key":20,"text":226,"correct":22},"50mm",{"key":24,"text":228,"correct":22},"100mm",{"key":28,"text":230,"correct":22},"125mm",{"key":31,"text":232,"correct":26},"150mm",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":28,"analysis":33},879104,"某洗衣房，最高日热水用水定额为15L\u002Fkg干衣，热水使用时间为8h，则该洗衣房最高日用水定额不应小于下列哪项？( )",[237,239,241,243],{"key":20,"text":238,"correct":22},"15L\u002Fkg干衣",{"key":24,"text":240,"correct":22},"25L\u002Fkg干衣",{"key":28,"text":242,"correct":26},"40L\u002Fkg干衣",{"key":31,"text":244,"correct":22},"80L\u002Fkg干衣",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":24,"analysis":33},879105,"以下有关自动喷水灭火系统按工程实际情况进行系统干式替代的叙述中，哪一项是不合理的？( )",[249,251,253,255],{"key":20,"text":250,"correct":22},"为避免系统管道充水低温结冰或高温气化，可用预作用系统替代湿式系统",{"key":24,"text":252,"correct":26},"在准工作状态严禁管道漏水的场所和为改善系统滞后喷水的现象，可采用干式系统替代预作用系统",{"key":28,"text":254,"correct":22},"在设置防火墙有困难时，可采用闭式系统保护防火卷帘的防火分隔形式替代防火分隔水幕",{"key":31,"text":256,"correct":22},"为扑救高堆垛仓库火灾，设置早期抑制快速响应喷头的自动喷水灭火系统，可采用干式系统替代湿式系统",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":28,"analysis":33},879106,"某雨水收集回用工程，水处理设备的出水存入雨水清水池。清水池设自动补水装置(补水采用自来水)，下列关于其补水设计，哪项错误？( )",[261,263,265,267],{"key":20,"text":262,"correct":22},"补水管侧壁进水池，管内底高于溢流水位2.5倍管径",{"key":24,"text":264,"correct":22},"补水管径按供水管网的最大小时用水量确定",{"key":28,"text":266,"correct":26},"补水管口设浮球阀控制补水的开、停",{"key":31,"text":268,"correct":22},"补水管上设水表计量补水量",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":24,"analysis":33},879107,"下列关于高层建筑生活热水供应系统设计的叙述中，哪项不正确？( )",[273,275,277,279],{"key":20,"text":274,"correct":22},"热水系统分区与冷水系统分区应一致",{"key":24,"text":276,"correct":26},"采用分区供水的热水供应系统，必须分别设置第二循环泵",{"key":28,"text":278,"correct":22},"配水立管设减压阀的热水分区供水方式，不宜用于建筑高度过高的建筑",{"key":31,"text":280,"correct":22},"建筑高度不高且其底部配水支管上设置减压阀时，其热水系统可不分区",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":31,"analysis":33},879108,"下列关于住宅小区的室外给水管道设计流量计算的说法中，哪项不正确？( )",[285,287,289,291],{"key":20,"text":286,"correct":22},"与用水定额有关",{"key":24,"text":288,"correct":22},"与卫生器具设置标准有关",{"key":28,"text":290,"correct":22},"与服务人数有关",{"key":31,"text":292,"correct":26},"与住宅类别无关",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":28,"analysis":33},879109,"生活给水系统贮水设施的有效容积按百分比取值时，下列哪项是错误的？( )",[297,299,301,303],{"key":20,"text":298,"correct":22},"居住小区加压泵站贮水池容积，可按最高日用水量的15%～20%确定",{"key":24,"text":300,"correct":22},"建筑物内由水泵联动提升供水系统的高位水箱容积宜按最高日用水量的50%确定",{"key":28,"text":302,"correct":26},"吸水井的有效容积不应小于水泵3min设计秒流量",{"key":31,"text":304,"correct":22},"由外网夜间直接送水的高位水箱的生活用水调节容积可按最高日用水量确定",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":31,"analysis":33},879110,"关于建筑生活排水系统排水定额和其设计流量计算方法的叙述中，哪项错误？( )",[309,311,313,315],{"key":20,"text":310,"correct":22},"卫生器具额定排水流量大于或等于其相应冷水给水定额流量",{"key":24,"text":312,"correct":22},"建筑生活排水横管的排水能力与其管材、水力半径、排水坡度等有关",{"key":28,"text":314,"correct":22},"Ⅱ、Ⅲ类宿舍的生活排水系统，其设计秒流量计算方法不同",{"key":31,"text":316,"correct":26},"居住小区生活排水系统的设计流量应为小区内各类建筑物最高日最大小时用水量的累计值乘以85%～95%",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":31,"analysis":33},879111,"某建筑采用机械循环集中热水供应系统，循环水泵的扬程0.28MPa，循环水泵处的静水压力为0.72MPa，则循环水泵壳体承受的工作压力(MPa)不得小于下列哪项？( )",[321,323,325,327],{"key":20,"text":322,"correct":22},"0.28",{"key":24,"text":324,"correct":22},"0.44",{"key":28,"text":326,"correct":22},"0.72",{"key":31,"text":328,"correct":26},"1.00",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":331,"answer":28,"analysis":33},879112,[332,333,334,335],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":26},{"key":31,"text":33,"correct":22},{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":31,"analysis":33},879113,"下列关于雨水水质处理工艺的叙述中，哪项正确？( )",[340,342,344,346],{"key":20,"text":341,"correct":22},"雨水处理工艺的选择只考虑原水水质与回用水质",{"key":24,"text":343,"correct":22},"大多数情况下宜采用膜法处理雨水",{"key":28,"text":345,"correct":22},"雨水回用于冲厕时可不设消毒工艺",{"key":31,"text":347,"correct":26},"沉淀一过滤是处理屋面雨水的常规工艺之一",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":350,"answer":24,"analysis":33},879114,[351,353,355,357],{"key":20,"text":352,"correct":22},"3个",{"key":24,"text":354,"correct":26},"4个",{"key":28,"text":356,"correct":22},"5个",{"key":31,"text":358,"correct":22},"7个",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":24,"analysis":33},879115,"下列哪项的全部水质指标都需在工厂车间就地处理达标后排放？( ) A.",[363,365,367,369],{"key":20,"text":364,"correct":22},"总汞、六价铬、总β放射性",{"key":24,"text":366,"correct":26},"CO",{"key":28,"text":368,"correct":22},"石油类、总汞",{"key":31,"text":33,"correct":22},{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":20,"analysis":33},879116,"在城市和工业企业中，排水制度的基本方式一般分为下列哪项？( )",[374,376,378,380],{"key":20,"text":375,"correct":26},"合流制与分流制",{"key":24,"text":377,"correct":22},"合流制、分流制、混流制",{"key":28,"text":379,"correct":22},"完全分流制、不完全分流制、合流制、混流制",{"key":31,"text":381,"correct":22},"完全分流制、不完全分流制、完全合流制、不完全合流制",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":20,"analysis":33},879117,"对截流式合流制溢流污水可采用下列哪种方法进行处理？( )",[386,388,390,391],{"key":20,"text":387,"correct":26},"格栅、沉淀、消毒",{"key":24,"text":389,"correct":22},"氧化沟",{"key":28,"text":33,"correct":22},{"key":31,"text":392,"correct":22},"沉砂、除油",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":24,"analysis":33},879118,"在新修订的《室外排水设计规范》GB50014-2006(2014版)中，为什么将设计暴雨强度公式中的折减系数取值为17( )",[397,399,401,403],{"key":20,"text":398,"correct":22},"为减少雨水管渠设计计算的工作量",{"key":24,"text":400,"correct":26},"为了提高雨水管渠运行安全性",{"key":28,"text":402,"correct":22},"为了减少雨水管渠系统的投资",{"key":31,"text":404,"correct":22},"因为原折减系数的理论有错误",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":28,"analysis":33},879119,"为了对污水处理厂的排水泵站内可能产生的有害气体进行监测，必须在泵站内配置哪种监测仪？( )",[409,410,411,412],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":26},{"key":31,"text":413,"correct":22},"ORP监测仪",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":28,"analysis":33},879120,"下列关于双壁波纹PVC-U管、HDPE管特性的叙述中，哪项不正确？( )",[418,420,422,424],{"key":20,"text":419,"correct":22},"强度高，耐压耐冲击",{"key":24,"text":421,"correct":22},"内壁平滑，摩阻低",{"key":28,"text":423,"correct":26},"管节短，接头多",{"key":31,"text":425,"correct":22},"施工快，工期短",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":31,"analysis":33},879121,"下列关于生物膜处理法具有较好硝化效果的叙述中，哪一项是正确的？( )",[430,432,434,436],{"key":20,"text":431,"correct":22},"生物膜是高度亲水物质，容易吸收污水中氮",{"key":24,"text":433,"correct":22},"生物膜中可生长原生动物，有利于氮的去除",{"key":28,"text":435,"correct":22},"生物膜沉降性能好，氮随脱落的生物膜排放",{"key":31,"text":437,"correct":26},"生物膜泥龄长，能存活世代时间长的微生物",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":28,"analysis":33},879122,"下列关于排水系统规划设计的叙述中，哪项不正确？( )",[442,444,446,448],{"key":20,"text":443,"correct":22},"排水工程的规划应符合区域规划以及城市和工业企业的总体规划",{"key":24,"text":445,"correct":22},"排水工程规划与设计要考虑污水的再生利用和污泥的合理处置",{"key":28,"text":447,"correct":26},"含有有毒、有害物质的工业废水，必须处理达标后直接排入水体，不允许经处理后排入城市污水管道",{"key":31,"text":449,"correct":22},"排水工程规划与设计应考虑与邻近区域和区域内给水系统、排洪系统相协调",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":28,"analysis":33},879123,"某城镇污水处理厂采用活性污泥法工艺，污水自流进入，则计算二沉池面积时，其设计流量应按下列哪项取值？( )",[454,456,458,460],{"key":20,"text":455,"correct":22},"污水的最大时(最高日)流量，再加上回流污泥量",{"key":24,"text":457,"correct":22},"污水的平均时(最高日)流量，再加上回流污泥量",{"key":28,"text":459,"correct":26},"污水的最大时(最高日)流量即可，不需加上回流污泥量",{"key":31,"text":461,"correct":22},"污水的平均时(最高日)流量，不需加上回流污泥量",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":28,"analysis":33},879124,"在传统活性污泥处理系统中，关于污泥回流的目的，下述哪种说法是正确的？( )",[466,468,470,472],{"key":20,"text":467,"correct":22},"反硝化脱氮",{"key":24,"text":469,"correct":22},"厌氧释磷",{"key":28,"text":471,"correct":26},"维持曝气池中的微生物浓度",{"key":31,"text":473,"correct":22},"污泥减量",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":24,"analysis":33},879125,"以下关于城镇排水管道系统选择中，哪项正确？( )",[478,480,482,484],{"key":20,"text":479,"correct":22},"雨水管道系统之间或合流制管道系统之间，严禁设置联通管",{"key":24,"text":481,"correct":26},"排水管道系统的设计，应以重力流为主，不设或少设提升泵站",{"key":28,"text":483,"correct":22},"输送腐蚀性污水的管道须采用耐腐蚀的材料，但接口及附属构筑物可不做防腐处理",{"key":31,"text":485,"correct":22},"排水管道断面尺寸应按远期规划的最高日平均时设计流量设计，按现状水量复核",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":24,"analysis":33},879126,"某市合流制与分流制排水系统并存，在晴天时两个系统排水都进入城市污水厂，但雨天时污水厂生化处理系统只能接纳合流管渠的部分混合污水。请判断下列采取的两种管渠系统连接方式，哪种方式对接纳水体污染最严重？( )",[490,492,494,496],{"key":20,"text":491,"correct":22},"两个系统独立进入污水厂初沉池，出水再混合进入生化处理系统；雨天时，管渠混合污水在初沉池后溢流",{"key":24,"text":493,"correct":26},"两个系统排水在污水厂进水井混合，晴天全部进行处理；雨天时，通过提升泵站溢流排放",{"key":28,"text":495,"correct":22},"在污水厂前设置合流管渠截留井，截留管与分流管渠连接后进污水厂；截留井溢流混合污水经沉淀后排入水体",{"key":31,"text":497,"correct":22},"两个系统排水在污水厂初沉池混合，雨天时，初沉池后溢流",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":24,"analysis":33},879127,"关于排水体质，下述说法哪项正确？( )",[502,504,506,508],{"key":20,"text":503,"correct":22},"拟建综合管廊的新城区宜采用不完全分流制",{"key":24,"text":505,"correct":26},"老城区建筑密度大、街道窄的城镇可保留合流制",{"key":28,"text":507,"correct":22},"建筑密度较大的新城区应采用截流式合流制",{"key":31,"text":509,"correct":22},"降雨量大的城镇应采用合流制",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":24,"analysis":33},879128,"下列关于污水管道衔接，说法错误的是哪项？( )",[514,516,518,520],{"key":20,"text":515,"correct":22},"污水管道从上游缓坡大管径与下游陡坡小管径衔接时，应采用管底平接",{"key":24,"text":517,"correct":26},"污水管道与倒虹管进、出水井衔接，应采用水面平接",{"key":28,"text":519,"correct":22},"污水管道在地面坡度很大的地域敷设时，可采用跌水衔接",{"key":31,"text":521,"correct":22},"污水管道上、下游管段管径相同时，宜采用管顶平接",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":31,"analysis":33},879129,"生物膜法滤料表面的生物膜由好氧和厌氧两层组成。下列关于生物膜传质与生物平衡关系叙述中，哪项不正确？( )",[526,528,530,532],{"key":20,"text":527,"correct":22},"有机物的降解主要是在好氧层内进行的",{"key":24,"text":529,"correct":22},"空气中的氧溶解于流动水层中，通过附着水层传递给生物膜，供微生物呼吸",{"key":28,"text":531,"correct":22},"污水中的有机污染物通过流动水层传递给附着水层，然后进入生物膜，通过细菌的代谢活动而被降解",{"key":31,"text":533,"correct":26},"厌氧层逐渐加厚，达到一定程度时，将与好氧层形成一定的平衡与稳定关系",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":31,"analysis":33},879130,"下列关于污泥的土地利用，说法错误的是哪项？( )",[538,540,542,544],{"key":20,"text":539,"correct":22},"污泥必须经过处理达到稳定化、无害化、减量化方可土地利用",{"key":24,"text":541,"correct":22},"污泥的土地利用途径主要是农田、林地、园林绿化利用等",{"key":28,"text":543,"correct":22},"污泥农田利用区应建立严密的使用、管理、检测和控制体系",{"key":31,"text":545,"correct":26},"污泥达到标准后种植纤维作物的施用量、施用期限可不受限制解",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":28,"analysis":33},879131,"以下关于污水厂沉淀池的表面负荷和适用条件中哪一项是不恰当的？( )",[550,552,554,556],{"key":20,"text":551,"correct":22},"初沉池设计表面负荷一般大于二沉池",{"key":24,"text":553,"correct":22},"辐流式沉淀池适用于大中型污水处理厂",{"key":28,"text":555,"correct":26},"竖流式沉淀池适合做二沉池",{"key":31,"text":557,"correct":22},"平流式沉淀池适用于大中小型污水处理厂",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":20,"analysis":33},879132,"两相厌氧法是由两级厌氧反应器组成的一种新型高效厌氧生物处理工艺，下列关于两相厌氧法工艺特点的描述，哪一项是不正确的？( )",[562,564,566,568],{"key":20,"text":563,"correct":26},"第一级反应器可实现大部分有机物的降解",{"key":24,"text":565,"correct":22},"第一级反应器的水力负荷高，第二级反应器水力负荷低",{"key":28,"text":567,"correct":22},"第一级反应器基本上不产生甲烷气，第二级反应器出水基本呈中性",{"key":31,"text":569,"correct":22},"由两级反应器组成的两相厌氧工艺总容积小于相同处理效率的混合相单级厌氧消化工艺",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":31,"analysis":33},879133,"当水体受到污染时，通过下列哪项指标的测定可判断其污染可能来源于生活污水？( )",[574,575,577,579],{"key":20,"text":33,"correct":22},{"key":24,"text":576,"correct":22},"表面活性剂",{"key":28,"text":578,"correct":22},"重金属离子",{"key":31,"text":580,"correct":26},"粪大肠菌群",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":31,"analysis":33},879134,"下列关于城镇排水系统布置形式的说明中，哪项错误？( )",[585,587,589,591],{"key":20,"text":586,"correct":22},"在地势向水体有一定倾斜的地区，可以采用正交式",{"key":24,"text":588,"correct":22},"在地势向水体有一定倾斜的地区，可以采用截流式",{"key":28,"text":590,"correct":22},"在地势向水体倾斜较大的地区，可以采用平行式",{"key":31,"text":592,"correct":26},"在地势向水体倾斜很大的地区，可以采用分散式",{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":31,"analysis":33},879135,"下列哪个公式不是活性污泥反应动力学的基础方程？( )",[597,599,601,603],{"key":20,"text":598,"correct":22},"米-门公式",{"key":24,"text":600,"correct":22},"莫诺特方程",{"key":28,"text":602,"correct":22},"劳-麦方程",{"key":31,"text":604,"correct":26},"哈森-威廉姆斯公式",[606,609,612,615,618,621],{"id":15,"name":607,"category":7,"favorite":608},"领导干部任职前廉政法规知识测试题",92,{"id":610,"name":611,"category":7,"favorite":15},595,"建筑结构与设备",{"id":613,"name":614,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":616,"name":617,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":619,"name":620,"category":7,"favorite":8},534,"BIM工程师",{"id":622,"name":620,"category":7,"favorite":8},535]